If you can't view the Datasheet, Please click here to try to view without PDF Reader . |
|
Datasheet File OCR Text: |
(R) MICROVERTER RO MICROVERTER (R) DC-DC Converters, 200-250 Watt Family World's Most Advanced Ultra High Density Single and Triple Output DC-DC Converters Up to 252 Watts 28, 48, and 300 VDC Input Evaluation Boards and Triple Output Modules Available DESCRIPTION MicroVerter modules are high density DCDC converters designed for use in telecom and other centralized modular and distributed power applications. Three input voltage ranges are available and all use metal PC boards, planar transformers, and surface mount construction to produce up to 252 watts in a tiny package. MODEL SELECTION Model Number Input 28 VDC 48 VDC 300 VDC (36-72V) (220-400V) (20-32V) Single Output V28-2 V48-2 V300-2 V28-3 V48-3 V300-3 V28-5 V48-5 V300-5 V28-8 V48-8 V300-8 V28-12 V48-12 V300-12 V28-15 V48-15 V300-15 V28-24 V48-24 V300-24 V28-28 V48-28 V300-28 Triple Output V28-T512 V48-T512 V300-T512 Output Voltage Current 2.1V 3.3V 5V 8V 12V 15V 24V 28V 5V 12V -12V 5V 15V -15V 60A 50A 40A 30A 20A 16A 10A 9A 35A* 3A* 3A* 35A* 3A* 3A* F E AT U R E S Miniature Size High Density - Up to 58 W/in.3 Constant Frequency - 370KHz Parallelable with Current Sharing Fault Tolerant - n+m Redundancy Extremely Low Thermal Resistance Output Good Signal Synchronization Option UL, CSA, & TUV Approvals Non-Shutdown Over Voltage Protection Logic On-Off Thermal Protection Current Limit/Short Circuit Protection Isolated Auxiliary Outputs V28-T515 V48-T515 V300-T515 *Maximum Total Output Power 185 W. (See p. 19 for min. load requirements.) Option: --S Synchronization Feature 12 RO Associates, Inc. * Sunnyvale, CA * 408 744-1450 * Fax: 408 744-1521 * email: sales@roassoc.com M I C R O V E R T E R (R) V 2 8 S E R I E S S P E C I F I C AT I O N S INPUT Input voltage Brownout In rush charge Input reflected ripple No load power dissipation Logic disabled power in Input ripple rejection Input overvoltage OUTPUT (Singles and Main Output of Triple) Set point accuracy Load regulation Line regulation Ripple Trim range Remote sense compensation OVP (non shutdown auto. recovery) Current Limit (auto.recovery) Current sharing (automatic) Transient response singles Transient response main output triples Transient response (see page 19) Temp drift Efficiency (see curves page 17) OUTPUT (Auxiliary Outputs of Triples) Set point accuracy Load regulation Line regulation Ripple Current Limit (auto. recovery) Transient response Transient response Transient response Temp drift CONTROL Turn on time Logic turn on time Logic disabled current ISOLATION Input to output Input to case Output to case Input to output capacity THERMAL Operating temperature Automatic shut down temperature Thermal resistance case to ambient WEIGHT singles triples SIZE singles triples (outline drawings see page 16) 1000 1000 200 2200 -40 +100 +100 +110 VDC VDC VDC pF C case C case C/w C/w oz. oz. inches inches consult factory for procedure MIN 20 18 TYPICAL 24-28 2.6x10-4 20 1.5 7.5 0.35 60 32 60 1 .2 .2 3 0.5 120* 110-120 5 50 200 .02 MAX 32 UNITS VDC VDC Coulombs % watts watts watts dB VDC % % % %p-p % V total % % % s s %/C CONDITIONS 75% full output power full load, nominal line singles triples @ 120 Hz no damage to units no load 0 to full load over range 0 to 20 MHz consult factory for extended range * or Vout +.5V whichever is greater full load full load 20-80% load,.5A/s, Vout 1% 10-20A, aux. loads 2.5A, .25A/s, Vout 1% .02 .02 1 10 0.5 .2 .01 .25 110-120 200 200 200 .06 2.5 1 1 1 .5 .1 .5 % % % %p-p % s s s %/C ms ms mA 10A on main, no load auxiliaries 0 to full load over range 0 to 20 MHz full load 20-80% load, Vout within 1% low line to high line, Vout 1% 50-100% load, Vout 1% input power applied, Vout 1% Vout within 1% sink +105 4.2 3.3 7 9 0.5x2.4x3.6 0.5x2.4x4.6 single @ Tc=100C triple @ Tc=100C RO Associates, Inc. * Sunnyvale, CA * 408 744-1450 * Fax: 408 744-1521 * email: sales@roassoc.com 13 V28 SERIES SERIES M I C R O V E R T E R (R) V 4 8 S E R I E S S P E C I F I C AT I O N S INPUT Input voltage Brownout In rush charge Input reflected ripple No load power dissipation Logic disabled power in Input ripple rejection Input overvoltage OUTPUT (Singles and Main Output of Triple) Set point accuracy Load regulation Line regulation Ripple Trim range Remote sense compensation OVP (non shutdown auto. recovery) Current Limit (auto.recovery) Current sharing (automatic) Transient response singles Transient response main output triples Transient response (see page 19) Temp drift Efficiency (see curves page 17) OUTPUT (Auxiliary Outputs of Triples) Set point accuracy Load regulation Line regulation Ripple Current Limit (auto.recovery) Transient response Transient response Transient response Temp drift CONTROL Turn on time Logic turn on time Logic disabled current ISOLATION Input to output Input to case Output to case Input to output capacity THERMAL Operating temperature Automatic shut down temperature Thermal resistance case to ambient singles triples SIZE singles triples (outline drawings see page 16) WEIGHT 3000 1500 500 2200 -40 +100 +100 +110 MIN 36 32 TYPICAL 48 2.6x10-4 20 2.5 7.5 1 60 72 100 1 .2 .2 3 0.5 120* 110-120 5 50 200 .02 MAX 72 UNITS VDC VDC Coulombs % watts watts watts dB VDC % % % %p-p % V total % % % s s %/C CONDITIONS 75% full output power full load, nominal line singles triples @ 120 Hz no damage to unit no load 0 to full load over range 0 to 20MHz consult factory for extended range * or Vout +.5V whichever is greater full load full load 20-80% load,.5A/s, Vout 1% 10-20A, aux. loads 2.5A, .25A/s, Vout 1% V48 .02 .02 1 10 0.5 .2 .01 .25 200 200 200 .06 2.5 1 1 1 .5 .1 .5 110-120 % % % %p-p s s s %/C ms ms mA VDC VDC VDC pF C case C case C/w C/w oz. oz. inches inches 10A on main, no load auxiliaries 0 to full load over range 0 to 20 mHz % full load 20-80% load, Vout within 1% low line to high line, Vout 1% 50-100% load, Vout 1% input power applied, Vout 1% Vout within 1% sink consult factory for procedure +105 4.2 3.3 7 9 0.5x2.4x3.6 0.5x2.4x4.6 single @ Tc=100C triple @ Tc=100C 14 RO Associates, Inc. * Sunnyvale, CA * 408 744-1450 * Fax: 408 744-1521 * email: sales@roassoc.com M I C R O V E R T E R (R) V 3 0 0 S E R I E S S P E C I F I C AT I O N S INPUT Input voltage Brownout In rush charge Input reflected ripple No load power dissipation Logic disabled power in Input ripple rejection (120Hz) OUTPUT (Singles and Main Output of Triple) Set point accuracy Load regulation Line regulation Ripple Trim range Remote sense compensation OVP (non shutdown auto. recovery) Current Limit (auto.recovery) Current sharing (automatic) Transient response singles Transient response main output triple Transient response (See page 19) Temp drift Efficiency (See curves page 17) OUTPUT (Auxiliary Outputs of Triples) Set point accuracy Load regulation Line regulation Ripple Current Limit (auto.recovery) Transient response Transient response Transient response Temp drift CONTROL Turn on time Logic turn on time Logic disabled current ISOLATION Input to output Input to case Output to case Input to output capacity THERMAL Operating temperature Automatic shut down temperature Thermal resistance case to ambient WEIGHT SIZE singles triples singles triples 4500 2500 500 5700 -40 +100 +100 +110 MIN 220 180 TYPICAL 300 4.5x10-5 20 2.5 7.5 1 60 1 .2 .2 3 0.5 120* 110-120 5 50 200 .02 MAX 400 UNITS VDC VDC Coulombs % watts watts watts dB % % % %p-p % V total % % % s s %/C CONDITIONS 75% full output power full load, nominal line singles triples @ 120 Hz no load 0 to full load over range 0 to 20 MHz consult factory for extended range * or Vout +.5V whichever is greater full load full load 20-80% load,.5A/s, Vout 1% 10-20A, aux. loads 2.5A, .25A/s, Vout 1% 10 .02 .02 1 +10, -30 0.5 .2 .01 .25 110-120 200 200 200 .06 250 2 1 1 .5 .1 .5 % % % %p-p % s s s %/C ms ms mA VDC VDC VDC pF C case C case C/w C/w oz. oz. inches inches 10A on main, no load auxiliaries 0 to full load over range 0 to 20 mHz full load 20-80% load, Vout within 1% low line to high line, Vout 1% 50-100% load, Vout 1% input power applied, Vout 1% Vout within 1% sink consult factory for procedure +105 4.2 3.3 7 9 0.5x2.4x3.6 0.5x2.4x4.6 single @ Tc=100C triple @ Tc=100C (outline drawings see page 16) RO Associates, Inc. * Sunnyvale, CA * 408 744-1450 * Fax: 408 744-1521 * email: sales@roassoc.com 15 V300 SERIES OUTLINE RO MICROVERTER SINGLE OUTPUT (R) Outline Drawings MICROVERTER (R) Note: Filled pins (marked *) are not provided in V300 series models TRIPLE OUTPUT Note: Filled pins (marked *) are not provided in V300 series models 16 RO Associates, Inc. * Sunnyvale, CA * 408 744-1450 * Fax: 408 744-1521 * email: sales@roassoc.com Performance Data EFFICIENCY CURVES 2, 3, & 5V Output Models 85 EFFICIENCY, PERCENT 5V 12 & 24V Output Models 90 EFFICIENCY, PERCENT 80 3.3V 85 12V 24V 75 2V 80 70 OUTPUT POWER, WATTS OUTPUT POWER, WATTS Triple Output Models 85 EFFICIENCY, PERCENT EFFICIENCY, PERCENT 85 Triple Output Models 80 5V@ 22A 80 75 5V@ 13A 75 5V@5A 70 50 100 150 200 70 50 100 150 200 OUTPUT POWER, WATTS 5V Load Fixed, Aux. Output Loads Varied From 0 to 3A Each OUTPUT POWER, WATTS Aux. Loads Fixed at 2A, 5V Load Varied All Loads Varied Note: Typical Efficiency for Tc = 25C and Nominal Input. Input and Output Measured at the Pins. RO Associates, Inc. * Sunnyvale, CA * 408 744-1450 * Fax: 408 744-1521 * email: sales@roassoc.com 17 MICROVERTER 50 100 150 200 75 50 100 150 200 250 (R) PERFORMANCE PERFORMANCE RO MICROVERTER (R) Performance Data (continued) THERMAL PERFORMANCE Thermal Performance-Single Output 5 100 OUTPUT POWER, % OF FULL LOAD 4 75 3 2 50 1 25 (R) 0 MICROVERTER 0 25 50 75 AMBIENT TEMPERATURE, C 100 1 - With No Heatsink and No Airflow 2 - With 2005 Heatsink and No Airflow or, with a 2.2C/W Heatsink 3 - With 2005 Heatsink and 200 LFM Airflow or, with a 1.8C/W Heatsink 4 - With 2005 Heatsink and 400 LFM Airflow or with a 1.2C/W Heatsink 5 - Output Power vs. Case Temperature. No Derating Required for Tc<100C Thermal Performance-Triple Output Models 5 100 OUTPUT POWER, % OF FULL LOAD 4 75 3 2 50 1 25 0 0 25 50 75 AMBIENT TEMPERATURE, C 100 1 - With No Heatsink and No Airflow 2 - With 2006 Heatsink and No Airflow or, with a 2.0C/W Heatsink 3 - With 2006 Heatsink and 200 LFM Airflow or, with a 1.5C/W Heatsink 4 - With 2006 Heatsink and 400 LFM Airflow or with a 1.0C/W Heatsink 5 - Output Power vs. Case Temperature. No Derating Required for Tc<100C 18 RO Associates, Inc. * Sunnyvale, CA * 408 744-1450 * Fax: 408 744-1521 * email: sales@roassoc.com OUTPUT RIPPLE & TRANSIENT RESPONSE Output Ripple Output Ripple 1 1 s 50 mV 1 Vout 50 s 100mV 2 Iout 50 s 10A 1 5V Transient Response Transient 2 100 MS/s MODEL V48-5. 48V INPUT, 40A LOAD, DSO, 400MHZ ANALOG BW, 100 MS/s SAMPLING. 100 MS/s MODEL V48-5 LOAD STEP 8A-32A-8A. CURRENT SLEW RATE 0.5A/s. 0A MINIMUM LOAD - TRIPLES Minimum 5V Load vs. Auxiliary Output Power V28 & V48-Triple Output Models 2.0 2.0 Minimum 5V Load vs. Auxiliary Output Power y V300 Triple Output Models 1.5 5V LOAD A 5V LOAD A 1.5 1.0 Tc=100C 0.5 Tc=70C 0.0 30 36 42 48 54 60 66 72 78 84 90 AUXILIARY OUTPUT POWER, WATTS 1.0 Tc=100C 0.5 Tc=25C 0.0 30 36 42 48 54 60 66 72 78 84 90 AUXILIARY OUTPUT POWER, WATTS RO Associates, Inc. * Sunnyvale, CA * 408 744-1450 * Fax: 408 744-1521 * email: sales@roassoc.com 19 MICROVERTER (R) PERFORMANCE |
Price & Availability of UV28-15
![]() |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |