![]() |
|
If you can't view the Datasheet, Please click here to try to view without PDF Reader . |
|
Datasheet File OCR Text: |
75 Watt HE Single Series DC/DC Converters Features ! Small Size 2.4" x 2.28" x 0.55" ! Industry Standard Pinout ! Excellent Thermal Performance with Metal Baseplate ! High Efficiency ! Volt-seconds Clamp and Fast Over Voltage Clamp ! Pulse-by-pulse Current Limiting, Short Circuit ! ! ! ! ! Description The 75 watt single HE series DC/DC converters provide precisely regulated dc outputs. All outputs are fully isolated from the inputs, allowing the output to be used with positive or negative polarity and various grounding options. The HE series meets the most rigorous requirements in an industry standard case size for industrial process control and telecom applications. Standard features include remote sensing, output trim, and remote on/off. Threaded-through holes are provided to allow easy mounting or to add a heat sink for extended temperature use. ! ! ! ! ! ! ! ! ! ! ! Frequency Foldback, Dead Short Shutdown Over-temperature Protection Auto-softstart Low Noise Planar Magnetics Constant Frequency for Normal Operation More than 2:1 Input Voltage Range Remote Sense Remote ON/OFF Super Energy Saving, 2 mA Input Idle Current Output Trim with Very Low Temperature Coefficient Water Washable, Wide Humidity Applications Shock & Vibration Damping Low Cost Undervoltage Lockout Input Reverse Voltage Protection 5 Year Warranty Selection Chart Model 12S3.15HE 12S5.15HE 24S3.15HE 24S5.15HE 24S12.6HE 24S15.5HE 24S24.3HE 48S3.15HE 48S5.15HE 48S12.6HE 48S15.5HE 48S24.3HE V in nom VDC 12 12 24 24 24 24 24 48 48 48 48 48 I in ADC 5.03 7.35 2.52 3.63 3.59 3.55 3.55 1.24 1.80 1.78 1.76 1.76 V out VDC 3.3 5 3.3 5 12 15 24 3.3 5 12 15 24 I out ADC 15 15 15 15 6.25 5 3.13 15 15 6.25 5 3.13 A NOTES: Efficiencies up to 88%. Default ON/OFF logic is positive. Add -N to the model number to order negative ON/OFF logic. 2401 Stanwell Drive * Concord, California 94520 * Ph: 925/687-4411 or 800/542-3355 * Fax: 925/687-3333 * www.calex.com * Email: sales@calex.com 1 12/23/2002 75 Watt HE Single Series DC/DC Converters Unless otherwise stated, these specifications apply for ambient temperature TA=23 2C, nominal input voltage, and rated full load. (1) Input Parameters Model Voltage Range Input Ripple Rejection (120Hz) Undervoltage Lockout Input Reverse Voltage Protection Input Current No Load 100% Load Inrush Current Reflected Ripple, 12H Source Impedance (2) Efficiency Switching Frequency Maximum Input Overvoltage 100 ms Maximum Recommended Fuse Model Voltage Range Input Ripple Rejection (120Hz) Undervoltage Lockout MIN TYP MAX TYP 24S3.15HE 24S5.15HE 24S12.6HE 18 24 36 60 Yes Yes 12 2.52 12 3.63 12 3.59 0.5 20 82 86 87 440 50 (3) 48S3.15HE MIN TYP MAX TYP 48S5.15HE 48S12.6HE 36 48 75 60 Yes Yes 12 1.24 12 1.80 12 1.78 0.5 20 83 87 88 440 85 (3) 89 89 12 1.76 12 1.76 mA A A2 S mA P-P % kHz VDC AMPS 48S15.5HE 48S24.3HE 88 88 12 3.55 12 3.55 mA A A2 S mA P-P % kHz VDC AMPS Units VDC TYP TYP MAX TYP TYP TYP MAX 82 440 25 (3) 24S15.5HE 24S24.3HE 15 5.03 0.5 20 85 MIN TYP MAX TYP 12S3.15HE 9 12 18 60 Yes Yes 15 7.35 mA/A A2 S mA P-P % kHz VDC AMPS Units VDC dB 12S15.5HE Units VDC dB Input Reverse Voltage Protection Input Current No Load TYP 100% Load TYP Inrush Current MAX Reflected Ripple, 12H TYP Source Impedance (2) Efficiency TYP Switching Frequency TYP Maximum Input Overvoltage* MAX 100 ms Maximum Recommended Fuse Model Voltage Range Input Ripple Rejection (120Hz) Undervoltage Lockout A dB Input Reverse Voltage Protection Input Current No Load TYP 100% Load TYP Inrush Current MAX Reflected Ripple, 12H TYP Source Impedance (2) Efficiency TYP Switching Frequency TYP Maximum Input Overvoltage* MAX 100 ms Maximum Recommended Fuse 2401 Stanwell Drive * Concord, California 94520 * Ph: 925/687-4411 or 800/542-3355 * Fax: 925/687-3333 * www.calex.com * Email: sales@calex.com 2 12/23/2002 75 Watt HE Single Series DC/DC Converters Output Parameters Model Output Voltage Output Voltage Setpoint Accuracy Turn On Overshoot Temperature Coefficient Noise (8) RMS Noise Load Current (4) Load Transient Overshoot (7) Load Transient Recovery Time (6) Load Regulation (5) Min-Max Load Line Regulation Vin = Min-Max Overvoltage Protection (OVP) Threshhold OVP Type - Non-latching Open Loop Overvoltage Clamp Output Current Limit V out=90% of V out-nom Output Short Circuit Protection V out = 0.25 V MAX TYP TYP MAX MAX TYP MIN MAX TYP TYP TYP MAX TYP MAX TYP MAX 0.005 0.01 75 20 12S3.15HE 24S3.15HE 48S3.15HE 3.3 12S5.15HE 24S5.15HE 48S5.15HE 5 24S12.6HE 48S12.6HE 12 1 0 0.003 0.005 75 20 150 60 5 100 2.5 100 0.02 0.2 0.01 0.1 120 135 150 60 250 100 24S15.5HE 48S15.5HE 15 24S24.3HE 48S24.3HE 24 Units VDC % % %/C mV P-P mV RMS % I out rated % Sec % % % % % TYP TYP MAX 120 140 150 2.28 1.90 1.400 1.000 1 2 3 4 5 6 7 0.400 0.000 0.50 8 9 Mounting inserts M3 x 0.5 though 4 places 0.080O 1.400 1.000 0.700 0.400 0.000 0.040O A Pin 1 2 3 4 5 6 7 8 9 0.2 TYP 0.000 0.55 2.00 2.40 Function -INPUT CASE ON/OFF +INPUT -OUTPUT -SENSE TRIM +SENSE +OUTPUT 0.19 0.000 BOTTOM VIEW 1.900 2.09 SIDE VIEW 2401 Stanwell Drive * Concord, California 94520 * Ph: 925/687-4411 or 800/542-3355 * Fax: 925/687-3333 * www.calex.com * Email: sales@calex.com 3 12/23/2002 75 Watt HE Single Series DC/DC Converters General Specifications All Models Remote ON/OFF Function HIGH Logic Level or Leave Pin Open External Leakage Current for Logic High Input Diode Protection Voltage LOW Logic Level or Tie ON/OFF Pin to -Input Sinking Current for Logic Low Open Circuit Voltage (10) Positive Logic Negative Logic Output Resistance Idle Current (Module is OFF) Turn-on Time to 1% error Positive Logic Negative Logic Output Voltage Remote Sensing Maximum Voltage Drops MAX on Leads Line Regulation Under TYP Remote Sensing MAX Load Regulation Under TYP Remote Sensing MAX Output Voltage Trim MIN Trim Range MAX Input Resistance TYP Open Circuit Voltage TYP Sense and Trim Limit Maximum Output Voltage TYP Units NOTES: Refer to the CALEX Application Notes for the definition of terms, measurement circuits, and other information. (2) 33 F capacitor connected to two "Input" pins. Then place current sensor in series with 12 H inductor between 33 F and source. The reflected ripple current is measured over 5 Hz to 20 MHz bandwidth. (3) Refer to the CALEX Application Notes for information on fusing. (4) Optimum performance is obtained when this power supply is operated within the minimum to maximum load specifications. No damage to module will occur, when the output is operated at less than minimum load, but the output voltage may contain a low frequency component that may exceed output noise specifications. (5) Load regulation is defined as the output voltage change when changing load current from maximum to minimum. (6) Load Transient Recovery Time is defined as the time for the output to settle from a 50 to 75% step load change to a 1% error band (rise time of step = 2Sec). (7) Load Transient Overshoot is defined as the peak overshoot during a transient as defined in the Note 6 above. (8) Noise is measured per the CALEX Application Notes. Output noise is measured with a 10F tantalum capacitor in parallel with a 0.1 F ceramic capacitor connected across the output to CMN. Measurement bandwidth is 0-20 MHz. (9) When an external On/Off switch is used, such as open collector switch, logic high requires the switch to be high-impedance. Switch leakage currents greater than 10 uA may be sufficient to trigger the ON/Off to the logic-low state. (10) Most switches would be suitable for logic On/Off control, in case there is a problem, you can make following estimations and then leave some margins. When open collector is used for logic high, "Open Circuit Voltage at On/Off Pin", "Output Resistance" and "External Leakage Current Allowed for Logic High" are used to estimate the high impedance requirement of open collector. When switch is used for logic low, "Open Circuit Voltage at On/ Off Pin", "Output Resistance" and "LOW Logic Level" are used to estimate the low impedance requirement of switch. (11) Specifications subject to change without notice. (1) MAX MAX MAX MIN MAX TYP TYP TYP TYP TYP 3.0 10 50 1.0 500 2.3 1.5 3 2 VDC A VDC VDC A VDC VDC k Ohm mADC 20 mSec HIGH - Module ON LOW - Module OFF HIGH - Module OFF LOW - Module ON 0.5 0.02 0.1 0.05 0.2 -10 +10 10 2.5 110 VDC % % % of Vout kohm V % of Vout Isolation Input to Output Isolation* 10A Leakage V nom =12 V, 24 V MAX V nom = 48 V MAX Input to Output Resistance TYP Input to Output Capacitance TYP Environmental Calculated MTBF, Bellcore Method 1, Case 1 Baseplate Operating MIN Temperature Range MAX Storage Temperature Thermal Impedance Thermal Shutdown Baseplate Temperature (Auto Restart) General Unit Weight Case Dimension Approvals (pending) Chassis Mounting Kit MIN MAX TYP MIN TYP TYP 700 1500 10 1800 106 -40 100 -40 120 7 100 110 VDC VDC M ohm pF Hr C C C/W C A 4/114 oz/g 2.4" x 2.28" x 0.55" UL1950, CUL, EN60950 (TUV) MS20 * Absolute Maximum Ratings. Caution: Stresses in excess of the Absolute Maximum Ratings can cause permanent damage to the device (see Note 1). 2401 Stanwell Drive * Concord, California 94520 * Ph: 925/687-4411 or 800/542-3355 * Fax: 925/687-3333 * www.calex.com * Email: sales@calex.com 4 12/23/2002 |
Price & Availability of 12S515HE
![]() |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |