If you can't view the Datasheet, Please click here to try to view without PDF Reader . |
|
Datasheet File OCR Text: |
CRF02 TOSHIBA Fast Recovery Diode Silicon Diffused Type CRF02 Power Supply Applications Strobo Flasher Applications * * * * * Repetitive peak reverse voltage: VRRM = 800 V Average forward current: IF (AV) = 0.5 A Low forward voltage: VFM = 3.0 V (max.) Very fast reverse-recovery time: trr = 100 ns (max.) Suitable for compact assembly due to its small surface-mount package, the "S-FLATTM" (Toshiba package name) Unit: mm Absolute Maximum Ratings (Ta = 25C) Characteristics Repetitive peak reverse voltage Average forward current Peak one-cycle surge forward current (non-repetitive) Junction temperature Storage temperature range Symbol VRRM IF(AV) IFSM Tj Tstg Rating 800 0.5 (Note 1) 10 (50 Hz) -40~150 -40~150 Unit V A A C C JEDEC JEITA TOSHIBA 3-2A1A Note 1: Ta = 84C: Device mounted on a ceramic board Board size: 50 mm x 50 mm, Soldering Land size: 2 mm x 2 mm Board thickness: 0.64 t Rectangular waveform ( = 180) Weight: 0.013 g (typ.) Note 2: Using continuously under heavy loads (e.g. the application of high temperature/current/voltage and the significant change in temperature, etc.) may cause this product to decrease in the reliability significantly even if the operating conditions (i.e. operating temperature/current/voltage, etc.) are within the absolute maximum ratings. Please design the appropriate reliability upon reviewing the Toshiba Semiconductor Reliability Handbook ("Handling Precautions"/Derating Concept and Methods) and individual reliability data (i.e. reliability test report and estimated failure rate, etc). 1 2006-11-07 CRF02 Electrical Characteristics (Ta = 25C) Characteristics Peak forward voltage Repetitive peak reverse current Repetitive peak reverse current Reverse recovery time Symbol VFM IRRM(1) IRRM(2) trr IFM = 0.5 A VRRM = 400 V VRRM = 800 V IF = 1 A, di/dt = -30 A/s Device mounted on a ceramic board (board size: 50 mm x 50 mm) (soldering land: 2 mm x 2 mm) (board thickness: 0.64 t) Thermal resistance Rth (j-a) Device mounted on a glass-epoxy board (board size: 50 mm x 50 mm) (soldering land: 6 mm x 6 mm) (board thickness: 1.6 t) Device mounted on a glass-epoxy board (board size: 50 mm x 50 mm) (soldering land: 1.2 mm x 1.2 mm) (board thickness: 1.6 t) Thermal resistance (junction to lead) Rth (j-) Test Condition Min Typ. 2.2 Max 3.0 3.0 50 100 Unit V A A ns 70 140 C/W 240 20 C/W Marking Abbreviation Code F2 Part No. CRF02 Standard Soldering Pad Unit: mm 1.2 1.2 2.8 Handling Precaution The absolute maximum ratings mean the absolute maximum ratings, which are rated values and must not be exceeded during operation, even for an instant. The followings are the general derating method that we recommend for designing a circuit using this device. VRRM: We recommend that the worst-case voltage, including surge voltage, be no greater than 80% of the absolute maximum rating of VRRM for a DC circuit; and no greater than 50% of that of VRRM for an AC circuit. VRRM has a temperature coefficient (0.1%/). Be sure to take this temperature coefficient into account when designing a device at low temperature. IF(AV): We recommend that the worst case current be no greater than 80% of the absolute maximum rating of IF(AV). Carry out sufficient heat design. If it is not possible to design a circuit with excellent heat radiation, set a margin by using an allowable Tamax-IF (AV) curve. This rating specifies the non-repetitive peak current in one cycle of a 50-Hz sine wave, condition angle 180. Therefore this applies only to abnormal operation, which seldom occurs during the lifespan of the device. For this device, we recommend a Tj of below 120 under the worst load and heat radiation conditions. Thermal resistance between junction and ambient fluctuates depending on the mounting condition of the device. When using the device, be sure to design the circuit board and soldering land size to match the appropriate thermal resistance value. Refer to the Rectifier databook for further information. 2 2006-11-07 CRF02 iF - vF 10 1.0 Pulse test PF (AV) - IF (AV) 180 iF (A) Average forward power dissipation PF (AV) (W) Tj = 150C 1 75C 25C 0.1 0.8 120 = 60 Instantaneous forward current 0.6 0.4 Rectangular waveform 0.2 0 360 Conduction angle: 0.01 0 1.0 2.0 3.0 4.0 5.0 6.0 7.0 0 0 0.2 0.4 0.6 0.8 Instantaneous forward voltage VF (V) Average forward current IF (AV) (A) Ta max - IF (AV) 160 Ta max - IF (AV) 160 Maximum allowable ambient temperature Ta max (C) Maximum allowable ambient temperature Ta max (C) 140 120 100 = 60 80 60 40 0 360 20 0 0 Conduction angle: 0.1 Rectangular waveform Device mounted on a glass-epoxy board (board size: 50 mm x 50 mm, land size: 6 mm x 6 mm) 140 120 100 80 60 40 0 360 20 0 0 Conduction angle: 0.1 0.2 Rectangular waveform = 60 Device mounted on a ceramic board (board size: 50 mm x 50 mm, land size: 2 mm x 2 mm) 120 0.3 0.4 180 0.5 0.6 0.7 0.8 120 0.3 0.4 180 0.5 0.6 0.7 0.8 0.2 Average forward current IF (AV) (A) Average forward current IF (AV) (A) Surge forward current 12 1000 Ta = 25C 10 f = 50 Hz rth (j-a) - t Device mounted on a glass-epoxy board (board size: 50 mm x 50 mm, land size: 1.2 mm x 1.2 mm, board thickness: 1.6 t) IFSM (A) Peak surge forward current 8 Transient thermal impedance rth (j-a) (C/W) 100 Device mounted on a glass-epoxy board (board size: 50 mm x 50 mm, land size: 6 mm x 6 mm, board thickness: 1.6 t) Device mounted on a ceramic board (board size: 50 mm x 50 mm, land size: 2 mm x 2 mm, board thickness: 0.64 t) 0.01 0.1 1 10 100 1000 6 4 10 2 0 1 3 5 10 30 50 100 1 0.001 Number of cycles Time t (ms) 3 2006-11-07 CRF02 RESTRICTIONS ON PRODUCT USE * The information contained herein is subject to change without notice. 20070701-EN * TOSHIBA is continually working to improve the quality and reliability of its products. Nevertheless, semiconductor devices in general can malfunction or fail due to their inherent electrical sensitivity and vulnerability to physical stress. It is the responsibility of the buyer, when utilizing TOSHIBA products, to comply with the standards of safety in making a safe design for the entire system, and to avoid situations in which a malfunction or failure of such TOSHIBA products could cause loss of human life, bodily injury or damage to property. In developing your designs, please ensure that TOSHIBA products are used within specified operating ranges as set forth in the most recent TOSHIBA products specifications. Also, please keep in mind the precautions and conditions set forth in the "Handling Guide for Semiconductor Devices," or "TOSHIBA Semiconductor Reliability Handbook" etc. * The TOSHIBA products listed in this document are intended for usage in general electronics applications (computer, personal equipment, office equipment, measuring equipment, industrial robotics, domestic appliances, etc.).These TOSHIBA products are neither intended nor warranted for usage in equipment that requires extraordinarily high quality and/or reliability or a malfunction or failure of which may cause loss of human life or bodily injury ("Unintended Usage"). Unintended Usage include atomic energy control instruments, airplane or spaceship instruments, transportation instruments, traffic signal instruments, combustion control instruments, medical instruments, all types of safety devices, etc.. Unintended Usage of TOSHIBA products listed in his document shall be made at the customer's own risk. * The products described in this document shall not be used or embedded to any downstream products of which manufacture, use and/or sale are prohibited under any applicable laws and regulations. * The information contained herein is presented only as a guide for the applications of our products. No responsibility is assumed by TOSHIBA for any infringements of patents or other rights of the third parties which may result from its use. No license is granted by implication or otherwise under any patents or other rights of TOSHIBA or the third parties. * Please contact your sales representative for product-by-product details in this document regarding RoHS compatibility. Please use these products in this document in compliance with all applicable laws and regulations that regulate the inclusion or use of controlled substances. Toshiba assumes no liability for damage or losses occurring as a result of noncompliance with applicable laws and regulations. 4 2006-11-07 |
Price & Availability of CRF02
![]() |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |