Part Number Hot Search : 
YDW236 F1459 APT20M 354202 212DH3 1N4148 XXXSE H83827R
Product Description
Full Text Search
 

To Download E3X-NA8 Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
 User-Friendly Fiber-Optic Amplifier
Solve Your Basic Sensing Challenges Easily with the E3X-NA Series
I I I
E3X-NA
I I I I I I
Streamlined features provide basic sensing immediately after plug-in Wire-saving amplifiers reduce installation time and minimize space requirements Master/slave connector design affords connectivity for up to 16 wire-saving amplifiers Use the LED bar display to quickly confirm sensor performance Optical communication design prevents mutual interference for up to 5 amplifiers Green LED models address mark-detecting applications High-speed models have a response time of 50 s Select a water-resistant model (IP66 rating) using an M8 connector Prewired water-resistant models are available
Ordering Information: Amplifier Units, Connectors, Accessories and Fiber-Optics
I
Amplifier Units with Cables
Part number NPN output PNP output
E3X-NA41 E3X-NA41F E3X-NAG41 ON/OFF E3X-NA11 E3X-NA11F E3X-NAG11
Type
Standard High-speed Mark-detection
Control output
Appearance
Water-resistant
E3X-NA11V
E3X-NA41V
E3X-NA
I
E3X-NA
Connector-Ready Amplifiers (Order Connector Separately)
Part number NPN output PNP output
E3X-NA8 E3X-NA6
Item
Wire-saving
Applicable connector (order separately)
Master E3X-CN11
Control output
ON/OFF output
Appearance
Slave
E3X-CN12
Water-resistant (M8 connectors)
E3X-NA14V
E3X-NA44V
XS3F-M421-40@-A @ XS3F-M422-40@-A @
I
Amplifier Unit Connectors (Order Separately)
Stickers for Connectors are included as accessories.
Note:
Item
Master Connector Slave Connector
Appearance
Cable length
2m
No. of conductors
3 1
Part number
E3X-CN11 E3X-CN12
I
Combining Amplifier Units and Connectors (Each Sold Separately)
Amplifier Units Type Wire-saving models NPN E3X-NA6 PNP E3X-NA8 Applicable Connectors (Order Separately) Master Connector Slave Connector E3X-CN12 (1-wire)
Refer to the following tables when placing an order. Amplifier Units and Connectors are sold separately.
+
E3X-CN11 (3-wire)
Example:
When Using 5 Amplifier Units Amplifier Units (5 Units)
+
1 Master Connector + 4 Slave Connectors
I
Sensor I/O Connectors (Order Separately)
Cable specifications
Standard cable
Size
M8
Appearance
Straight connector
Cable type
2m 5m Four-core cable
Part number
XS3F-M421-402-A XS3F-M421-405-A XS3F-M422-402-A XS3F-M422-405-A
L-shaped connector
2m 5m
I
Accessories (Order Separately)
Applicable models
E3X-NA@ E3X-NA@F E3X-NAG@ E3X-NA@V
I
Fiber-Optic Cables
Mounting Brackets
Appearance Quantity
1
Part number
E39-L143
The E3X-NA amplifiers use Omron's E32-series fiber-optic cables. With a choice of over 80 sensing heads, you are sure to find one that matches your application requirements. Refer to the selection of E32 cables (listed with their respective sensing distances) in the fiber section at the end of this data sheet. Order fiber-optic cables separately.
E39-L148
End Plate
Appearance Quantity
1
Part number
PFP-M
2
E3X-NA
E3X-NA
Specifications
I
Amplifier Units
Amplifier Units with Cables Standard models High-speed detection models E3X-NA11F E3X-NA41F Mark-detecting models E3X-NAG11 E3X-NAG41 Green LED (520 nm) 35 mA max. (for 24-VDC power supply) 35 mA max. Water-resistant models E3X-NA11V E3X-NA41V Red LED (680 nm) Connector-ready amplifier units Wire-saving models E3X-NA6 E3X-NA8 Water-resistant models (use M8 connectors) E3X-NA14V E3X-NA44V
Ratings/Characteristics
Item
Output type
NPN output PNP output
E3X-NA11 E3X-NA41 Red LED (680 nm)
Light source (wavelength) Supply voltage Current consumption
12 to 24 VDC 10%, ripple (p-p): 10% max. 35 mA max.
Control output Operation mode Switchselectable Response time
NPN/PNP (depends on model) open collector; load current: 50 mA max.; residual voltage: 1 V max. Light-ON/Dark-ON operation 200 s max. for operation and reset respectively (See note.) Operation: 20 s max. Reset: 30 s max. 200 s max. for operation and reset respectively (See Note.)
Sensitivity adjustment Circuit protection
8-turn sensitivity adjuster (with indicator) Reverse polarity, output Reverse short-circuit, mutual inter- polarity, output ference prevention (opti- short-circuit cally synchronized) OFF-delay timer: 40 ms (fixed) Incandescent lamp:10,000 lux max. Sunlight:20,000 lux max. Operating: Groups of 1 to 3 Amplifiers: -25C to 55C (-13F to 131F) Groups of 4 to11 Amplifiers: -25C to 50C (-13F to 122F) Groups of 12 to16 Amplifiers: -25C to 45C (-13F t0 113F) with no icing or condensation Storage: -30C to 70C (-22 F to 158F) with no icing or condensation Operating and storage: 35% to 85% (with no condensation) 20 M min. (at 500 VDC) 1,000 VAC at 50/60 Hz for 1 minute 10 to 55 Hz with a 1.5-mm double amplitude for 2 hrs each in X, Y and Z directions 500 m/s2, for 3 times each in X, Y and Z directions IEC60529 IP50 (with Protective Cover attached) IEC60529 IP66 (with Protective Cover attached) IEC60529 IP50 (with Protective Cover attached) Connector Approx. 110 g Polyethersulfone (PES) IEC60529 IP66 (with Protective Cover attached) 500 VAC at 50/ 60 Hz for 1 minute Reverse polarity, output short-circuit, mutual interference prevention (optically synchronized)
Timer function Ambient illumination (receiver side) Ambient temperature
Ambient humidity Insulation resistance Dielectric strength Vibration resistance Shock resistance Enclosure rating
Connection method Weight (packed) Material Case Cover Accessories Note:
Prewired (standard cable length: 2 m) Approx. 100 g Polybutylene terephthalate (PBT) Polycarbonate Instruction Sheet
M8 connector
Approx. 55 g Approx. 65 g Polycarbonate Polyethersulfone (PES)
When there are 8 or more Amplifier Units mounted side-by-side, the response time will be 350 s max.
I
Amplifier Unit Connectors
E3X-CN11
2.5 A 50 V 20 m max. (20 mVDC max., 100 mA max.) (The above figure is for connection to the Amplifier Unit and the adjacent Connector. It does not include the conductor resistance of the cable.) 50 times (for connection to the Amplifier Unit and the adjacent Connector) Polybutylene terephthalate (PBT) Phosphor bronze/gold-plated nickel Approx. 55 g Approx. 25 g Housing Contact
Item
Rated current Rated voltage Contact resistance
E3X-CN12
Number of insertions Material Weight (packed)
3
E3X-NA
E3X-NA
Nomenclature
I
Amplifier Units
Sensitivity Indicator 8-Turn Sensitivity Adjuster
Lock Button
Incident level Indicators Operation Indicator
Operation Mode Selector Use to switch between Light ON and Dark ON modes. Timer Switch ON: Timer function is ON. OFF: Timer function is OFF.
I
LED Bar Display
Indicators
In addition to an operation indicator (orange), the E3X-NA also has incident level indicators (4 green and 1 red). Use these indicators for optical axis adjustments and maintenance.
Status of indicators (in L/ON mode)
Operation indicator (in L/ON mode)
Not lit
Incident level
Operation indicator Incident level indicators
Approx. 80% max. of operating level
Not lit
Lit (See note.)
Not lit
Approx. 80% to 90% of operating level
Not lit or lit
Approx. 90% to 110% of operating level
Lit
Approx. 110% to 120% of operating level
Lit
Approx. 120% min. of operating level
Note:
The indicator farthest to the right will be lit even if the incident level is 0.
4
E3X-NA
E3X-NA
Operation
I
Output Circuits
Model Mode selector LIGHT ON (L/ON) Timing chart State of Output circuit output transistor Light ON
T
Operation indicator (orange) Photoelectric Sensor main circuit
1
Output
NPN
E3X-NA11 E3X-NA6 E3X-NAG11 E3X-NA11F E3X-NA11V E3X-NA14V
Incident light No incident light Operation indicator ON (orange) OFF Output transistor Load (relay) ON OFF
Brown
Load Black
4
Control output
Operate Release (Between brown and black)
12 to 24 VDC
Blue
3
DARK ON (D/ON)
Incident light No incident light Operation indicator ON (orange) OFF Output transistor Load (relay) ON OFF
Dark ON
T
M8 Connector Pin Arrangement
2 1 4 3
Operate Release (Between brown and black)
Note:
Light ON
Pin 2 is not used.
Brown
1
PNP
E3X-NA41 E3X-NA8 E3X-NAG41 E3X-NA41F E3X-NA41V E3X-NA44V
LIGHT ON (L/ON)
Incident light No incident light Operation indicator ON (orange) OFF Output transistor Load (relay) ON OFF
T
Operate Release (Between brown and black)
Operation indicator (orange) Photoelectric Sensor main circuit
4
Black
Control output 12 to 24 VDC Load
Blue
3
DARK ON (D/ON)
Incident light No incident light Operation indicator ON (orange) OFF Output transistor Load (relay) ON OFF
Dark ON
T
M8 Connector Pin Arrangement
2 1 4 3
Operate Release (Between brown and black
Note:
Pin 2 is not used.
I
Connectors (Sensor I/O Connectors)
Terminal number
4 3 2 1
1 2 3 4
Color of cable conductors
Brown White Blue Black
XS3F-M421-402-A, XS3F-M422-402-A XS3F-M421-405-A, XS3F-M422-405-A
Classification
DC
Color of cable conductors
Brown White Blue Black
Connection pin number
1 2 3 4
Application
Power supply (+V) --Power supply (0 V) Output
Note:
Pin 2 is not used.
5
E3X-NA
E3X-NA
Engineering Data (Typical)
I
Parallel Operating Range
E32-T11L/T12L
Distance Y (mm)
X
At max. sensitivity. (Use for optical axis adjustment at installation.)
Distance Y (mm)
300
300 200
Distance Y (mm)
E32-TC200
E3X-NAG@
200 100 0 -100 -200
Y
E32-T11R
X Y
200 150
X
E3X-NAG@
100 50 0 -50 0.1 0.2 0.3 0.4
Y
E3X-NAG@
100 0
0.2
0.4
0.6
0.8
1
1.2
0.5
1
1.5
2
2.5
0.5 0.6
0.7
Distance X (m)
-100
Distance X (m) E3X-NA@F
Distance X (m)
-100
E3X-NA@F
-300
E3X-NA@ (V)
-200
E3X-NA@ (V)
-300
-150 -200
E3X-NA@F
E3X-NA@ (V)
E32-T11
Distance Y (mm)
200 150 100 50 0 -50 -100 -150 -200 0.2 0.4 0.6 0.8 1
E32-TC200E
Distance Y (mm) E3X-NAG@
X Y
E32-T24S
Distance Y (mm)
X
80 60 40 20 0 50 100 150 200
30 20 10 0
X Y
E3X-NAG@
Y
250
300
0.4
0.8
1.2
1.6
2
Distance X (m) -20 E3X-NA@F
-40 -60
Distance X (mm)
-10 -20
Distance X (m)
E3X-NA@ (V)
-80
E3X-NA@F
E3X-NA@ (V)
-30
E3X-NA@F
E3X-NA@ (V)
I
Operating Range
E32-D11L
Distance Y (mm)
X Y
With standard sensing target at max. sensitivity. (Use for the positioning of the object and Sensor.)
E32-DC200
Distance Y (mm)
150 100
E32-D11R/D12R
Distance Y (mm)
X Y
150 100
30 20 10 0
X
E3X-NAG@
50 0
E3X-NAG@
50 0 -50
E3X-NAG@
Y
200
-50 -100 -150
300
400
300 100 200
400
500
40
80
120
160
200
100
Distance X (mm)
Distance X (mm)
-10 -20 -30
Distance X (mm)
E3X-NA@F E3X-NA@ (V)
-100 -150
E3X-NA@F E3X-NA@ (V)
E3X-NA@F
E3X-NA@ (V)
E32-DC200E
Distance Y (mm)
15 10
X Y
Distance Y (mm)
Distance Y (mm)
E32-D33
15 10
X Y
E32-L25L
1
X Y
E3X-NA@F
E3X-NAG@
5 0 10 -5
E3X-NA@F
5 0 5 -5 10 15
0.5
20
30
40
50
60
70
20
Distance X (mm)
25
0
2
4
6
8
10
Distance X (mm)
-0.5
Distance X (mm)
-10 -15
-10
E3X-NA@ (V)
E3X-NA@F
E3X-NA@ (V)
-15
-1
E3X-NA@ (V)
6
E3X-NA
I
E3X-NA
Number of Turns of Sensitivity Adjuster vs. Sensing Distance
E32-D11L
Distance (mm)
400 1.2 1.0 0.8
E32-T11L
Distance (m)
300
E3X-NA@ (V)
0.6 0.4
200
E3X-NA@ (V)
100 0.2
E3X-NA@F
0 2 4 6 8 10 0 2 4 6
@F
8 10
Number of turn ns
Number of t turns
Sensing Distance vs. Hysteresis
E32-T11L
Hysteresis (mm)
100 80
E32-D11L
Hysteresis (mm)
20
15
60
E3X-NA@ (V)
40
10
E3X-NA@ (V)
20
5
0
100
200
300
400
500
600 700
0
50
100
150
200
Distance (mm) (mm
Distance (mm)
7
E3X-NA
E3X-NA
Dimensions
Unit: mm (inch) I
Amplifier Units
Incident level indicators A (See note 1.) Operation indicator
Amplifier Units with Cables (with Mounting Bracket Attached)
E3X-NA11 E3X-NA11F E3X-NA41 E3X-NA41F E3X-NAG11 E3X-NAG41
Two, 2.4 dia.
10 (0.39)
Cable (See note 2.)
13.05 15.75 3
9.2 64.3 (2.53) 38.6 5.3
Mounting Holes
8 31.5 (1.24) 9.9 10.7 4.1 22.4 13 16 34.8 4 10.75 16
Two, M3
Hole for optical communications (See note 3.)
2.4
Two, 3.2 dia. holes
3.4 4.4
Mounting bracket (E39-L143) Stainless steel (SUS304)
22.4
16
Note:
1. The mounting bracket can also be used on side A. 2. With these models, a 4-dia., 3-conductor, vinyl-insulated round cable (conductor cross-sectional area: 0.45 mm 2; insulation diameter: 1.1 mm) is used. Standard length: 2 m. 3. The hole for optical communications is for preventing mutual interference. There is no hole for E3X-NA@F models.
Water-Resistant Amplifier Units with Cables (with Mounting Bracket Attached)
E3X-NA11V E3X-NA41V
28.65 25.95
9.2 (See note 2.)
Operation indicator Incident level indicators
81.5 (3.21) 12 (0.47) 6.9 40
A (See note 1.)
Two, 2.4 dia.
2.8 8 33 (1.29) 9.9 10.7 11.2
3.9
3.4
4.3 11.5
23.9 14.4 23.9
16 37 67.2 16 3.4 5.4
Hole for optical communications
Mounting Holes
Two, M3
6.6
Mounting bracket (E39-L148) Stainless steel (SUS304)
16 5.4 3.4
Note:
1. The mounting bracket can also be used on side A. 2. With these models, a 4-dia., 3-conductor, vinyl-insulated round cable (conductor cross-sectional area: 0.45 mm 2; insulation diameter: 1.1 mm) is used. Standard length: 2 m.
8
E3X-NA
Wire-Saving Amplifiers
Incident level indicators
E3X-NA
E3X-NA6 E3X-NA8
Operation indicator
10 (0.39)
13.05 15.75
9.2 64.3 (2.53)
Two, 2.4 dia.
3
8 9.9 10.7 3.4 1.8 13 5.1 3.9 1.7 4.2 1.8 38.6 36.7
31.5 14 (1.24)
5.5
Hole for optical communications (for preventing mutual interference)
6.2
1.7
Dimensions with Master Connector Connected
71 (2.80) 67.5 64.3
Dimensions with Slave Connector Connected
71 (2.80) 67.5 64.3
31.5 (1.24) 1.5
E3XCN11: 4.0 dia.
31.5 (1.24)
E3X-CN12: 2.6 dia.
12.95
1.5
17.45 12.95 11.55
1.8 5.1 3.9
4 10 (0.39)
1.8 5.1 3.9
3
4.8
4 10 (0.39)
M8 Connector-Ready, Water-Resistant Amplifier Units
E3X-NA14V E3X-NA44V
28.65 25.95
9.2
Operation indicator Incident level indicators
12 (0.47)
The mounting bracket can also be used on this side.
81.5 (3.21)
6.9
40
Two, 2.4 dia.
33 (1.30)
2.8 M8
8 9.9 10.7 11.2
3.9
3.4
4.3 11.5
23.9 14.4
16 37 67.2 16 3.4 5.4
Hole for optical communications
11
Mounting Holes
Two, M3
23.9
Mounting bracket (E39-L148) Stainless steel (SUS304)
16 5.4 3.4
9
E3X-NA
I
E3X-NA
Amplifier Unit Connectors (Order Separately)
10 6 2.9 2.6 2 m (6.56 ft.) 10.7 6.8 4
Master Connectors E3X-CN11
See note. 4 dia.
14.4
6
0.8
8.4 15.1
302 50 +5 0
102
Note: A 4-dia., 3-conductor, vinyl-insulated round cable (conductor cross-sectional area: 0.2 mm2; insulation diameter: 1.1 mm) is used.
Slave Connectors E3X-CN12
2.9
10 6
2 m (6.56 ft.) 10.7 6.8 2.6 4
See note. 2.6 dia.
14.4
6 3
0.8
8.4 15.1
302 50 +5 0
102
Note: A 2.6-dia., single-conductor, vinyl-insulated round cable (conductor cross-sectional area: 0.2 mm2; insulation diameter: 1.1 mm) is used.
I
Sensor I/O Connectors (Order Separately)
Straight Connector (at One End of Cable) XS3F-M421-402-A (L=2 m) XS3F-M421-405-A (L=5 m)
2.15 M8 12.9 4 2 9 dia. 1.95 0.5 3 3.4 1 21.5 31.4 L 30 50 5 4 dia.
L-shaped Connector (at One End of Cable) XS3F-M422-402-A (L=2 m) XS3F-M422-405-A (L=5 m)
L 23.1 30 50 5
20.5 4 dia.
9 dia. 3.4 2.15 0.5 1.95
10
E3X-NA
I
E3X-NA
Accessories (Order Separately)
Mounting Bracket for E3X-NA@, E3X-NA@F, and E3X-NAG@ Models
E39-L143
10.3 5.3 7.3 26.8 7 160.1 3 2.5 34.8 (1.37) 22 16
3
Mounting Holes
Two, M3
Two, 3.2 dia.
Material: Stainless steel (SUS 304)
10.3 10 max. 7
3
16
Four, R1.7
3.4 1 3.4 1
Mounting Bracket for E3X-NA@V Models
E39-L148
12 12 max. 9 2 3.4 9.5 22 16 160.1 7.3 3 4 27 35 (1.38) 3 4.3 1.5 9.1 Two, 3.2 dia. R1.7 16 R1.7
3.4
2
Mounting Holes
Two, M3
Material: Stainless steel (SUS 304)
End Plate
PFP-M
10 50 (1.97) 11.5
M4x8, pan-head screw
M4 spring washer
4.8 1 1.3 1.8 35.5 35.3 1.8
6.2
10
.
11
E3X-NA
E3X-NA
Precautions
I
Wiring Precautions
I
Wiring the Amplifier Unit
Read the following before using the Amplifier Unit and Sensor to ensure safety.
Cable The cable can be extended, provided that the extension wire applied is at least 0.3 mm2 thick and the total distance no more than 100 m. Do not pull the cable with a force exceeding 30N. Separation from Power or High-tension Lines Do not wire power lines or high-tension lines alongside the lines of the Amplifier Unit in the same conduit, otherwise the Amplifier Unit may be damaged or malfunction due to induction. Be sure to wire the lines of the Amplifier Unit as far as possible from power lines or high-tension lines or laid in an exclusive, shielded conduit.
Power Supply Voltage
Do not impose any voltage exceeding the rated voltage on the E3X-NA. Do not impose AC power (100 VAC) on models that operate with DC. In both cases, the E3X-NA may burst or burn.
Load Short-circuits
Do not short-circuit the load connected to the E3X-NA, or the E3X-NA may burst or burn.
Polarity
When supplying power to the E3X-NA, make sure that the polarity of the power is correct, or the E3X-NA may burst or burn.
No-load Operation
A load must be connected to the E3X-NA during operation, or internal elements may burst or burn. Always wire through a load.
Power line
Incorrect
Operating Environment
* Do not use the Amplifier Unit or Sensor in places with flammable or explosive gas. * Do not use the Amplifier Unit or Sensor underwater. * Do not disassemble, repair, or modify the Amplifier Unit or Sensor. I Power Supply If a standard switching regulator is used as a power supply, the frame ground (FG) terminal and the ground (G) terminal must be grounded, or faulty operation may result from the switching noise of the power supply. M8 Metal Connectors (Water-Resistant Models) Turn OFF the power before inserting or removing the connector. Hold the connector cover when inserting or removing the connector. Tighten the fixing screws by hand. Using tools such as pliers may cause damage. The applicable tightening torque range is 0.3 to 0.4 N*m. If tightening is insufficient, the enclosure rating may not be maintained, and vibrations may cause the connector to come loose.
Power
Turning Power ON The Sensor is ready to operate within 100 ms after the power supply is turned ON. If the Sensor and load are connected to power supplies separately, be sure to turn ON the power supply to the Sensor first. Turning Power OFF Pulses may be output when the power is turned OFF. Always turn OFF the power to the load or the load line first. Power Supply Type Do not connect the E3Z-NA to a full-wave or half-wave rectified power supply. Communications Hole The hole on the side of the Amplifier Unit is a communications hole for preventing mutual interference when Amplifier Units are mounted side-by-side. The E3X-MC11 Mobile Console (sold separately) cannot be used. If an excessive amount of light is received via the Sensor, the mutual interference prevention function may not work. In this case, make the appropriate adjustments using the sensitivity adjuster. The mutual interference prevention function will not operate when the E3X-NA is used side-by-side with E3X-DA-N models.
12
E3X-NA
I
E3X-NA
Removal
Pull the lock tab of the Amplifier Unit with a flat blade screwdriver in direction (3) and lift the fiber insertion part in direction (4) as shown below.
Mounting the Amplifier Unit
Mount the Amplifier Units one at a time onto the DIN rail.
Joining Amplifier Units
1.
(4)
2. Line up the clips and slide the Amplifier Units together. Then press the Amplifier Units together until they click into place.
DIN rail (3)
When side-mounting using a mounting bracket, secure the mounting bracket to the Amplifier Unit and then mount using M3 screws. Use plain washers of diameter 6mm or less when mounting.
Clip
Click into place
Separating Amplifier Units
Slide Amplifier Units away from each other, and remove from the DIN rail one at a time. (Do not attempt to remove Amplifier Units from the DIN rail without separating them first.) Note: 1. The specifications for ambient temperature will vary according to the number of Amplifier Units used together. For details, refer to Ratings/Characteristics in the Specifications section of this data sheet. 2. Always turn OFF the power supply before joining or separating Amplifier Units. Ambient Conditions Dust or dirt accumulation on the optical communications hole may prevent normal communications. Be sure to remove any dust or dirt before using the Unit.
Plain washers (6-mm dia. max.)
Operating Environment
Mounting
1. Mount the front part on the mounting bracket E39-L143 or E39-L148 (order separately) or onto a DIN rail. Do not mount the back of the Amplifier Unit onto the mounting bracket or the DIN rail first, or the mounting strength of the Amplifier Unit may be reduced. Always mount the front of the Amplifier Unit first.
Ratings and Specifications
The ratings and performance specifications for items such as the minimum sensing target and characteristics are based on products taken at random from certain production lots. Use this data as reference only.
2. Press the back part onto the mounting bracket or the DIN rail. Note:
Protective Cover
Be sure to mount the Protective Cover before use.
(2) (1) DIN rail
13
E3X-NA
I
E3X-NA
Mounting the Fiber Unit
Tightening Force
The tightening force applied to the Fiber Unit should be as shown below.
Protective cover Unlocked
Screw-Mounting Model
Spring mounting clip Toothed washers
Cylindrical Model
Retaining screw (flat head or sunken head) (M3 max.) Locked
Nuts (attachment)
Note:
To maintain the fiber properties, confirm that the lock is released before removing the fiber.
3. Precautions for Fiber Connection/Disconnection Fiber Units
M3/M4 screw M6 screw/ 6-mm dia. cylinder 1.5-mm dia. cylinder 2-mm dia./3-mm dia. cylinder E32-T12F 5-mm dia. Teflon model E32-D12F 6-mm dia. Teflon model E32-T16 E32-R21 E32-M21 E32-L25A E32-T16P E32-T16PR E32-T24S E32-L24L E32-L25L E32-T16J E32-T16JR E32-T16W E32-T16WR 0.49 N*m max. 0.59 N*m max. Up to 5 mm to the tip: 0.49 N*m max. More than 5 mm from the tip: 0.78 N*m max. 0.78 N*m max. 0.29 N*m max.
Temporarily fitted Thin fiber attachment (E39-F9)
Clamping torque
0.78 N*m max. 0.98 N*m max. 0.2 N*m max. 0.29 N*m max. 0.78 N*m max.
Be sure to lock or unlock the lock button within an ambient temperature range between -10C and 40C.
Cutting Fiber
Insert a fiber into the Fiber Cutter and determine the length of the fiber to be cut. Press down the Fiber Cutter in a single stroke to cut the fiber. The cutting holes cannot be used twice. If the same hole is used twice, the cutting face of the fiber will be rough and the sensing distance will be reduced. Always use an unused hole. Cut a thin fiber as follows: 1. An attachment is temporarily fitted to a thin fiber before shipment.
2. Secure the attachment after adjusting the position of it in the direction indicated by the arrow.
0.3 N*m max.
Use a proper-sized wrench. 3. Insert the fiber to be cut into the E39-F4.
Cutter (E39-F4)
Fiber Connection and Disconnection
The E3X-NA Amplifier Unit has a lock button. Connect or disconnect the fibers to or from the E3X-NA Amplifier Unit using the following procedures: 1. Connection Open the protective cover, insert the fibers according to the fiber insertion marks on the side of the Amplifier Unit, and lower the lock button.
Lock button Insertion position Three holes for standard fiber (2.2-mm dia.)
Two holes for thin fiber
4. Finished state (proper cutting state)
Approx. 0.5 mm
Insertion direction
Note:
Insert the fiber in the direction indicated by the arrow.
Fiber
Fiber insertion mark
10.7 mm
2. Disconnection Remove the protective cover and raise the lock button to pull out the fiber.
14
E3X-NA
Connection
Do not pull or press the Fiber Units. The Fiber Units have a withstand force of 9.8 N or 29.4 N maximum (pay utmost attention because the fibers are thin). Do not bend the edge of the Fiber Units (excluding the E32-T@R and E32-D@R). I
E3X-NA Mounting Amplifier Units with Connectors
Insert the Master or Slave Connector into the Amplifier Unit until it clicks into place.
Mounting Connectors
1.
Correct
20 mm min.
Incorrect
Amplifier Unit
Fiber Unit
Insert
2. Join Amplifier Units together as required after all the Master and Slave Connectors have been inserted.
20 mm min.
Do not apply excess force on the Fiber Units.
3. Attach the stickers (provided as accessories) to the sides of Master and Slave Connectors that are not connected to other Connectors.
Correct
Fiber Unit Nylon wireholder
Incorrect
Sticker
Sticker
The Fiber Head could be broken by excessive vibration.Use the following method to prevent fiber head breakage:
Note:
Attach the stickers to the sides with grooves.
Removing Connectors
1. Slide the slave Amplifier Unit for which the Connector is to be removed away from the rest of the group.
A one-turn loop can absorb vibrations.
Tape
2. After the Amplifier Unit has been separated, press down on the lever on the Connector and remove it. (Do not attempt to remove Connectors without separating them from other Amplifier Units first.)
Press down Lever
Bending Radius
E39-F11 Sleeve Bender The bending radius of the stainless steel tube should be as large as possible. The smaller the bending radius becomes, the shorter the sensing distance will be. Insert the tip of the stainless steel tube to the Sleeve Bender and bend the stainless steel tube slowly along the curve of the Sleeve Bender (refer to the figure).
1.2-mm dia. max. 1.3-mm dia. min. R 10 mm R 12.5 mm R 5 mm R 7.5 mm Fiber tip position mark
Remove
Stainless steel tube
90 max.
10 mm
10 mm
Do not bend here.
15
E3X-NA
I
E3X-NA
I
Mounting End Plate (PFP-M)
Reflector
Depending on how it is mounted, an Amplifier Unit may move during operation. In this case, use an End Plate. Before mounting an End Plate, remove the clip from the master Amplifier Unit using a nipper or similar tool.
Use of E39-R3 Reflector
Use detergent, etc., to remove any dust or oil from the surfaces where tape is applied. Adhesive tape will not be attached properly if oil or dust remains on the surface. The E39-R3 cannot be used in places where it is exposed to oil or chemicals.
E39-F32@ Protective Spiral Tubes
Insert a fiber to the Protective Spiral Tube from the head connector side (screwed) of the tube.
Clip
The clip can also be removed using the following mechanism, which is incorporated in the construction of the section underneath the clip. 1. Insert the clip that is to be removed into the slit underneath the clip on another Amplifier Unit.
Protective Spiral Tube
Fiber Unit
Push the fiber into the Protective Spiral Tube. The tube should be straight so that the fiber is not twisted when inserted. Then turn the end cap of the spiral tube.
Protective Spiral Tube
Fiber Unit
Secure the Protective Spiral Tube on a suitable place with the attached nut.
Mounting panel Hexagon clamping nut
2. Remove the clip by rotating the Amplifier Unit.
Rotate Protective Spiral Tube
Fiber Unit Toothed washer
Use the attached saddle to secure the end cap of the Protective Spiral Tube. To secure the Protective Spiral Tube at a position other than the end cap, apply tape to the tube so that the portion becomes thicker in diameter.
Pull Strengths for Connectors (Including Cables)
E3X-CN11: 30 N max. E3X-CN12: 12 N max.
Saddle Tube
End cap
I
E39-F10 Fiber Connector
Splice Fiber Unit Retention unit Retention unit Fiber Unit
Mount the Fiber Connector as shown in the following illustrations.
Fiber Unit
Fiber Unit
The Fiber Units should be as close as possible when they are connected. Sensing distance will be reduced by approximately 25% when fibers are connected. Only 2.2-mm-dia. fibers can be connected.
16
E3X-NA
E3X-NA
Sensing Distance with Fiber Optic Cables
I
Through-beam Fiber Units
Indicates models that allow free cutting. Models without this mark do not allow free cutting.
Refer to the end of the following table for notes and precautions.
Free-cut
: Red light
Application Features
: Green light
Appearance Applicable Amplifier Unit E3X-NA@ (V) E3X-NAG@
M4 screw
Sensing distance (mm) (Values in parentheses: when using the E39-F1 Lens Unit)
700 (2,000) 130 (370)
210 (600)
Standard object (see notes) (min. sensing target: opaque)
Part number
Permissible bending radius 25 mm
Long distance
M4
Free-cut
1.4-mm dia. (0.03-mm dia.)
E32-T11L
E3X-NA@F 3-mm dia.
Free-cut
E3X-NA@ (V) E3X-NAG@
3-mm dia.
700
130 210
1.4-mm dia. (0.5-mm dia.) 1.4-mm dia. (0.03-mm dia.)
E32-T12L
E3X-NA@F M3
Free-cut
E3X-NA@ (V) E3X-NAG@
M3 screw
200 40 60 200 40 60 14,000
4,200
1.4-mm dia. (0.5-mm dia.) 0.9-mm dia. (0.03-mm dia.)
E32-T21L
10 mm
E3X-NA@F 2-mm dia.; small diameter
Free-cut
E3X-NA@ (V) E3X-NAG@
2-mm dia.
0.9-mm dia. (0.2-mm dia.) 0.9-mm dia. (0.03-mm dia.)
E32-T22L
E3X-NA@F M14; with lens; ideal
Free-cut
E3X-NA@ (V)
M14 screw
for explosion-proofapplications
E3X-NA@F E3X-NA@ (V)
400 (3,000) 75 (550)
120 (900)
Generalpurpose
M4
Free-cut
0.9-mm dia. (0.2-mm dia.) 10-mm dia. (0.1-mm dia.) 10-mm dia. (1.5-mm dia.) 1.0-mm dia. (0.03-mm dia.)
E32-T17L
25 mm
E32-TC200
25 mm
M4 screw
E3X-NAG@ E3X-NA@F
M3; Free-cut possible to mount the reflective side-view conversion attachment E39-F5 M3; for Free-cut detecting minute sensing targets
E3X-NA@ (V) E3X-NAG@
M3 screw
360 65
100 100
1.0-mm dia. (0.2-mm dia.) 1.0-mm dia. (0.03-mm dia.)
E32-TC200A
25 mm
E3X-NA@F E3X-NA@ (V) E3X-NAG@
M3 screw
1.0-mm dia. (0.2-mm dia.) 0.5-mm dia. (0.03-mm dia.)
E32-TC200E
10 mm
20
30 100
E3X-NA@F Thin fiber 2-mm dia.; Free-cut for detecting minute sensing targets 1.2-mm dia.; with sleeve E3X-NA@ (V) E3X-NAG@
2-mm dia.
0.5-mm dia. (0.1-mm dia.) 0.5-mm dia. (0.03-mm dia.)
E32-T22
10 mm
20
30
E3X-NA@F
90 mm (40 mm)
Free-cut
E3X-NA@ (V) E3X-NAG@
75
120 100
400
0.5-mm dia. (0.1-mm dia.) 1.0-mm dia. (0.03-mm dia.)
E32-TC200B E32-TC200B4
25 mm
M4 screw
1.2-mm dia. ( ): E32-TC200B4
E3X-NA@F E3X-NA@ (V)
0.9-mm dia.; with sleeve
Free-cut
90 mm (40 mm) M3 screw 0.9-mm dia. ( ): E32-TC200F4
1.0-mm dia. (0.2-mm dia.) 0.5-mm dia. (0.03-mm dia.)
E32-TC200F E32-TC200F4
10 mm
E3X-NAG@ E3X-NA@F
20
30
0.5-mm dia. (0.1-mm dia.)
17
E3X-NA
Application Features Appearance Applicable Amplifier Unit E3X-NA@ (V) E3X-NAG@
M4 screw
E3X-NA
Sensing distance (mm) (Values in parentheses: when using the E39-F1 Lens Unit)
360 65
100 100 Standard object (see notes) (min. sensing target: opaque)
Part number
Permissible bending radius 4 mm
Flexible (R4)
Ideal for mounting on moving sections (R4)
Free-cut
1.0-mm dia. (0.03-mm dia.)
E32-T11
E3X-NA@F E3X-NA@ (V) E3X-NAG@
M3 screw
1.0-mm dia. (0.2-mm dia.) 0.5-mm dia. (0.03-mm dia.)
E32-T21
18
30 100
E3X-NA@F E3X-NA@ (V) E3X-NAG@
1.5-mm dia.
0.5-mm dia. (0.1-mm dia.) 0.5-mm dia. (0.03-mm dia.)
E32-T22B
18
30
E3X-NA@F M4
Free-cut
E3X-NA@ (V) E3X-NAG@
M4 screw
280 (2,100) 50 (375)
80 (600)
0.5-mm dia. (0.1-mm dia.) 1.0-mm dia. (0.03-mm dia.)
E32-T11R
1 mm
E3X-NA@F 3-mm dia.
Free-cut
E3X-NA@ (V) E3X-NAG@
3-mm dia.
280 (2,100) 50 (375)
80 (600)
1.0-mm dia. (0.2-mm dia.) 1.0-mm dia. (0.03-mm dia.)
E32-T12R
E3X-NA@F M3; small diameter
Free-cut
E3X-NA@ (V) E3X-NAG@
M3 screw
60 12 18 60 18 240 45
70
1.0-mm dia. (0.2-mm dia.) 0.5-mm dia. (0.03-mm dia.)
E32-T21R
1 mm
E3X-NA@F 2-mm dia.; small diameter Sideview Long distance; spacesaving
Free-cut
E3X-NA@ (V)
2-mm dia.
E3X-NA@F E3X-NA@ (V)
Free-cut
3-mm dia.
1.0-mm dia. (0.1-mm dia.) 0.5-mm dia. (0.03-mm dia.) 0.5-mm dia. (0.1-mm dia.) 1.0-mm dia. (0.03-mm dia.)
E32-T22R
1 mm
E32-T14L
25 mm
E3X-NAG@ E3X-NA@F
Spacesaving
Free-cut
3-mm dia.
E3X-NA@ (V) E3X-NA@F
33
110
Suitable Free-cut for detecting minute sensing targets Suitable for Free-cut detecting minute sensing targets Screwmounting type
Free-cut
E3X-NA@ (V)
1-mm dia.
90 12
27 30 9
1.0-mm dia. (0.2-mm dia.) 1.0-mm dia. E32-T14LR (0.03-mm dia.) 1.0-mm dia. (0.2-mm dia.) 0.5-mm dia. (0.03-mm dia.) E32-T24
1 mm
10 mm
E3X-NAG@ E3X-NA@F
1-mm dia.
E3X-NA@ (V) E3X-NA@F E3X-NA@ (V) E3X-NAG@ E3X-NA@F
1,800 330
540
0.5-mm dia. (0.3-mm dia.) 0.5-mm dia. E32-T24R (0.03-mm dia.) 0.5-mm dia. (0.3-mm dia.) 4.0-mm dia. (0.03-mm dia.) E32-T14
1 mm
25 mm
4.0-mm dia. (0.2-mm dia.)
18
E3X-NA
Application Features Appearance Applicable Amplifier Unit E3X-NA@ (V) E3X-NAG@
5-mm dia. 300
480
E3X-NA
Sensing distance (mm) (Values in parentheses: when using the E39-F1 Lens Unit)
Standard object (see notes) (min. sensing target: opaque)
Part number
Permissible bending radius 40 mm
Chemicalresistant
Teflon-covFree-cut ered *1; withstands chemicals and harsh environments (operating ambient temperature:-30C to 70C)
4.0-mm dia. (0.2-mm dia.)
E32-T12F
E3X-NA@F E3X-NA@ (V)
5-mm dia.
4.0-mm dia. (0.7-mm dia.) 3.0-mm dia. (0.2-mm dia.)
Teflon-covFree-cut ered *1; sideview; withstands chemicals and harsh environments (operating ambient temperature: -30C to 70C) Teflon *1; withstands chemicals and harsh environments (operating ambient temperature: -40C to 200 C)
200 37 60 350
100
E32-T14F
E3X-NAG@ E3X-NA@F E3X-NA@ (V)
3.0-mm dia. (0.7-mm dia.) 1.0-mm dia. (0.2-mm dia.) 1.0-mm dia. (0.5-mm dia.) 1.0-mm dia. (0.2-mm dia.) 1.0-mm dia. (0.5-mm dia.)
400
E32-T81F
10 mm
6-mm dia.
E3X-NA@F E3X-NA@ (V)
Heatresistant
Resists 200C; flexible (R10); fiber sheath material: Teflon *1 (operating ambient temperature: - 40C to 200 C) Resists Free-cut 150C *2; fiber sheath material: fluororesin (operating ambient temperature: -40C to 150C) Resists 300C *3, with spiral tube; high mechanical strength; fiber sheath material: stainless steel (operating ambient temperature: -40C to 300C) Side-view; Free-cut resists 150C *2; suitable for detecting minute sensing targets; fiber sheath material: fluororesin (operating ambient temperature: -40C to 150C)
180
50
E32-T81R
10 mm
M4 screw
E3X-NA@F E3X-NA@ (V)
1.5-mm dia. (0.03-mm dia.) 1.5-mm dia. (1.0-mm dia.)
E32-T51
35 mm
M4 screw
E3X-NA@F E3X-NA@ (V)
120
300 (3,000) M4 screw
1.0-mm dia. E32-T61 (0.03-mm dia.) 1.0-mm dia. (0.5-mm dia.) 1.0-mm dia. (0.03-mm dia.)
25 mm
E3X-NA@F
90
E3X-NA@ (V)
2-mm dia. 130
E32-T54
35 mm
E3X-NA@F
35
1.0-mm dia. (0.3-mm dia.)
Resists 200C *3; L-shaped; fiber sheath material: stainless steel
E3X-NA@ (V)
3-mm dia.
700
1.7-mm dia. E32-T84S (0.03-mm dia.) 1.7-mm dia. (0.4-mm dia.) 4.0-mm dia. (0.1-mm dia.)
25 mm
E3X-NA@F Slot sensor
Suitable for Free-cut film sheet detection; no optical axis adjustment required; easy to mount
210
E3X-NA@ (V) E3X-NAG@ E3X-NA@F
10 10 10 1,000
300
E32-G14
25 mm
4.0-mm dia. (1.0-mm dia.) 1.7-mm dia. (0.5-mm dia.)
Narrow vision field
Suitable for detecting wafers
Free-cut
E3X-NA@ (V)
3-mm dia.
E32-T22S
10 mm
E3X-NA@F E3X-NA@ (V) E3X-NA@F
Side-view; suitable for detecting wafers
Free-cut
3.5 mm dia. x 3
700
210
2.0-mm dia. (0.03-mm dia.) 2.0-mm dia. (0.5-mm dia.)
E32-T24S
19
E3X-NA
Application Features Appearance Applicable Amplifier Unit E3X-NA@ (V) E3X-NA@F
M3 screw 90 920 170
270
E3X-NA
Sensing distance (mm) (Values in parentheses: when using the E39-F1 Lens Unit)
300 Standard object (see notes) (min. sensing target: opaque)
Part number
Permissible bending radius 25 mm
Area sensing Multi-point detection
(4-head)
2.0-mm dia. E32-M21 (0.03-mm dia.) 2.0-mm dia. (0.3-mm dia.) (0.5-mm dia.) *4
Detects in a 30-mm area
Free-cut
E3X-NA@ (V) E3X-NAG@
30 mm
E32-T16W
10 mm
E3X-NA@F
Detects in a 30-mm area; flexible
(4.0-mm dia.) *4
690
Free-cut
E3X-NA@ (V)
(0.5-mm dia.) *4 (4.0-mm dia.) *4
E32-T16WR
1 mm
30 mm
E3X-NA@F
200
Side-view; Free-cut suitable for applications with limited spatial depth
E3X-NA@ (V) E3X-NAG@
11 mm 95
150
520
(0.3-mm dia.) *4
E32-T16J
10 mm
E3X-NA@F E3X-NA@ (V)
11 mm
(2.0-mm dia.) *4
390
Side-view; Free-cut suitable for applications with limited spatial depth; flexible
(0.3-mm dia.) *4 (2.0-mm dia.) *4
1,500
E32-T16JR
1 mm
E3X-NA@F E3X-NA@ (V) E3X-NAG@
110
Suitable for detecting over a 10-mm area; long distance
Free-cut
(0.9-mm dia.) *4
E32-T16
25 mm
275
450
10 mm
E3X-NA@F E3X-NA@ (V) E3X-NAG@
11 mm
(1.5-mm dia.) *4
600
Stable for Free-cut detecting minute sensing targets in a wide area; enclosure rating: IEC 60529 IP50
Stable for Free-cut detecting minute objects in a wide area; flexible; enclosure rating: IEC60529 IP50
(0.3-mm dia.) *4
E32-T16P
10 mm
110 180
E3X-NA@F E3X-NA@ (V)
11 mm
(2.0-mm dia.) *4
450
(0.3-mm dia.) *4 (2.0-mm dia.) *4
E32-T16PR
1 mm
E3X-NA@F
130
*1 Teflon is a registered trademark of the Dupont Company and the Mitsui Dupont Chemical Company for their fluoride resin. *2 For continuous operation, use the products within a temperature range of -40C to 130C. *3 Indicates the heat-resistant temperature at the fiber tip. *4 These figures are for a sensing distance of 100 mm. (Diameters of sensing targets are ones at a stationary state.) Note: 1. The size of standard sensing target is the same as the fiber core diameter (lens diameter for models with lens). 2. The values of the minimum sensing target for E3X-NA@ (V) and E3X-NAG@ through-beam models indicate those obtained where the sensing distance and sensitivity are set to optimum values. 3. The value of the minimum sensing target for E3X-NA@F through-beam models indicates that obtained at the rated sensing distance with the sensitivity set to the optimum value.
20
E3X-NA
I
E3X-NA
Fiber Units with Reflective Sensors
Indicates models that allow free cutting. Models without this mark do not allow free cutting.
Refer to the end of the following table for notes and precautions.
Free-cut
: Red light
Application Features
: Green light
Appearance Applicable Amplifier Unit Sensing distance (mm) *1
Standard object (see note) (min. sensing target: Gold wire)
Part number
Permissible bending radius 25 mm
Long distance
M6
Free-cut
E3X-NA@ (V) E3X-NAG@
M6 screw 35
65
200
250x250 (0.01-mm dia.) 50x50 (0.1-mm dia.) 100x100 (0.015-mm dia.) 150x150 (0.01-mm dia.) 25x25 (0.1-mm dia.) 50x50 (0.015-mm dia.) 100x100 (0.01-mm dia.) 25x25 (0.1-mm dia.) 25x25 (0.015-mm dia.) 100x100 (0.01-mm dia.) 25x25 (0.1-mm dia.) 25x25 (0.015-mm dia.)
E32-D11L
E3X-NA@F 3-mm dia.; small diameter E3X-NA@ (V) E3X-NAG@
3-mm dia.
Free-cut
120
E32-D12
20
40 50
E3X-NA@F M4
Free-cut
E3X-NA@ (V) E3X-NAG@
M4 screw
E32-D21L
10 mm
10
17 50
E3X-NA@F 3-mm dia.; small diameter E3X-NA@ (V) E3X-NAG@
3-mm dia.
Free-cut
E32-D22L
10
17
E3X-NA@F Generalpurpose M6 E3X-NA@ (V) E3X-NAG@
M6 screw
Free-cut
150
200x200 (0.01-mm dia.) 50x50 (0.1-mm dia.) 75x75 (0.015-mm dia.) 50x50 (0.01-mm dia.) 25x25 (0.1-mm dia.) 25x25 (0.02-mm dia.)
E32-DC200
25 mm
25
50
E3X-NA@F M3; small diameter E3X-NA@ (V) E3X-NAG@ E3X-NA@F Thin fiber 2.5-mm dia.; with sleeve
Free-cut
Free-cut
36 6 12
150
E32-DC200E
10 mm
M3 screw
E3X-NA@ (V)
90 mm (40 mm)
200x200 (0.01-mm dia.) 50x50 (0.1-mm dia.) 75x75 (0.015-mm dia.) 50x50 (0.01-mm dia.) 25x25 (0.1-mm dia.) 25x25 (0.02-mm dia.) 25x25 (0.01-mm dia.) 25x25 (0.03-mm dia.) 25x25 (0.01-mm dia.) 25x25 (0.05-mm dia.)
E32-DC200B E32-DC200B4
25 mm
E3X-NAG@
M6 screw 2.5-mm dia. ( ): E32-DC200B4
25
50
E3X-NA@F E3X-NA@ (V)
1.2-mm dia.; with sleeve
Free-cut
36 6 12 10
3.3
90 mm (40 mm)
E32-DC200F E32-DC200F4
10 mm
E3X-NAG@
M3 screw 1.2-mm dia. ( ): E32-DC200F4
E3X-NA@F E3X-NA@ (V)
0.8-mm Free-cut dia.; for detecting minute sensing targets 0.5-mm dia.; for detecting minute sensing targets
3-mm dia. 0.8-mm dia.
E32-D33
4 mm
E3X-NA@F E3X-NA@ E3X-NA@F
0.5-mm dia. 2-mm dia.
1.5
0.5
E32-D331
4 mm
21
E3X-NA
Application Features Appearance Applicable Amplifier Unit Sensing distance (mm) *1
Standard object (see note) (min. sensing target: Gold wire)
E3X-NA
Part number Permissible bending radius 4 mm
Flexible
Ideal for mounting on moving sections
Free-cut
E3X-NA@ (V) E3X-NAG@
M6 screw 15
30
90
150x150 (0.01-mm dia.) 25x25 (0.1-mm dia.) 50x50 (0.015-mm dia.) 25x25 (0.01-mm dia.) 25x25 (0.02-mm dia.)
E32-D11
E3X-NA@F E3X-NA@ (V)
Free-cut
15
5
E32-D21
M3 screw
E3X-NA@F E3X-NA@ (V) E3X-NAG@
15 2.4
5
25x25 (0.01-mm dia.) 25x25 (0.1-mm dia.) 25x25 (0.02-mm dia.) 25x25 (0.01-mm dia.) 25x25 (0.02-mm dia.)
E32-D21B
Free-cut
M4 screw
E3X-NA@F E3X-NA@ (V)
1.5-mm dia.
7
2.3
E32-D22B
E3X-NA@F E3X-NA@ (V) E3X-NAG@
M6
Free-cut
90 15
30
150x150 (0.01-mm dia.) 25x25 (0.1-mm dia.) 50x50 (0.02-mm dia.) 150x150 (0.01-mm dia.) 25x25 (0.1-mm dia.) 50x50 (0.02-mm dia.) 25x25 (0.01-mm dia.) 25x25 (0.03-mm dia.)
E32-D11R
1 mm
M6 screw
E3X-NA@F 3-mm dia. E3X-NA@ (V) E3X-NAG@
3-mm dia.
Free-cut
90 15
30
E32-D12R
E3X-NA@F M3; small diameter E3X-NA@ (V)
M3 screw
Free-cut
15
5
E32-D21R
E3X-NA@F E3X-NA@ (V)
3-mm dia.; small diameter
Free-cut
15
5
25x25 (0.01-mm dia.) 25x25 (0.03-mm dia.)
E32-D22R
3-mm dia.
E3X-NA@F
22
E3X-NA
Application Features Appearance Applicable Amplifier Unit Sensing distance (mm) *1
Standard object (see note) (min. sensing target: Gold wire)
E3X-NA
Part number Permissible bending radius 25 mm
Coaxial
M6coaxial; highprecision positioning
Free-cut
E3X-NA@ (V) E3X-NAG@
M6 screw 25
50
150
200x200 (0.01-mm dia.) 50x50 (0.1-mm dia.) 75x75 (0.015-mm dia.)
E32-CC200
E3X-NA@F 3-mm dia. Free-cut coaxial; small diameter; highprecision positioning E3X-NA@ (V) E3X-NAG@
3-mm dia.
80 12
25 40 6 13
100x100 (0.01-mm dia.) 25x25 (0.1-mm dia.) 50x50 (0.02-mm dia.) 50x50 (0.01-mm dia.) 25x25 (0.1-mm dia.) 25x25 (0.02-mm dia.) 25x25 (0.01-mm dia.) 25x25 (0.02-mm dia.) 25x25 (0.01-mm dia.) 25x25 (0.02-mm dia.)
E32-D32L
E3X-NA@F M3 coaxial; Free-cut highprecision positioning; possible to mount small-spot lens (E39-F3A-5/ F3B/F3C) M3 coaxial; highprecision positioning; possible to mount small-spot lens (E39-F3A-5/ F3B/F3C) 2-mm dia. coaxial; high-precision positioning; possible to mount small-spot (0.1 to 0.6 dia.) lens (E39-F3A) 2-mm dia. Free-cut coaxial; highprecision positioning; possible to mount small-spot (0.5 to 1 dia.) lens (E39-F3A) Side-view 6-mm dia.; long distance
Free-cut
E3X-NA@ (V) E3X-NAG@ E3X-NA@F E3X-NA@ (V)
M3 screw
E32-C31
M3 screw
15
E32-C41
E3X-NA@F E3X-NA@ (V)
5
15
E32-C42
2-mm dia.
E3X-NA@F
5
E3X-NA@ (V) E3X-NAG@
2-mm dia.
6
40
50x50 (0.01-mm dia.) 25x25 (0.1-mm dia.) 25x25 (0.02-mm dia.) 50x50 (0.03-mm dia.) 25x25 (0.3-mm dia.) 25x25 (0.03-mm dia.) 25x25 (0.03-mm dia.)
E32-D32
E3X-NA@F E3X-NA@ (V)
6-mm dia.
13 40
E32-D14L
25 mm
E3X-NAG@ E3X-NA@F
10
13 16
6-mm dia.; flexible
Free-cut
E3X-NA@ (V)
6-mm dia.
E32-D14LR
1 mm
E3X-NA@F 2-mm dia.; small diameter; flexible, space-saving
Free-cut
5
E3X-NA@ (V)
2-mm dia.
15 2.4
5
25x25 (0.03-mm dia.) 25x25 (0.3-mm dia.) 25x25 (0.03-mm dia.) 25x25 (0.03-mm dia.)
E32-D24
10 mm
E3X-NAG@ E3X-NA@F
2-mm dia.; Free-cut small diameter space-saving; flexible Chemicalresistant TeflonFree-cut covered *3; withstands chemicals and harsh environments (operating ambient temperature: -30C to 70C)
E3X-NA@ (V)
2-mm dia.
7
2.3 50 8 16
E32-D24R
1 mm
E3X-NA@F E3X-NA@ (V) E3X-NAG@
6-mm dia.
100x100 (0.03-mm dia.) 25x25 (0.3-mm dia.) 25x25 (0.03-mm dia.)
E32-D12F
40 mm
E3X-NA@F
23
E3X-NA
Application Features Appearance Applicable Amplifier Unit Sensing distance (mm) *1
Standard object (see note) (min. sensing target: Gold wire)
E3X-NA
Part number Permissible bending radius 35 mm
Heatresistant
Resists 150C Free-cut *2; fiber sheath material: fluororesin (operating ambient temperature: -40C to 150C)
E3X-NA@ (V)
M6 screw
120
150x150 (0.03-mm dia.) 50x50 (0.03-mm dia.) 100x100 (0.03-mm dia.) 25x25 (0.03-mm dia.) 50x50 (0.03-mm dia.)
E32-D51
E3X-NA@F E3X-NA@ (V)
40
Resists 300C *4; fiber sheath material: stainless steel (operating ambient temperature: -40C to 300C) Resists 400C *4; fiber sheath material: stainless steel (operating ambient temperature: -40C to 400C)
45
E32-D61
25 mm
M6 screw
E3X-NA@F E3X-NA@ (V)
15
E32-D73
30
1.25-mm dia. M4 screw
E3X-NA@F
10
25x25 (0.03-mm dia.)
Area sensing Side-view;
detection over wide areas
Free-cut
E3X-NA@ (V) E3X-NA@F
M6 screw Reflector E39-R3
75 25
100x100 (0.03-mm dia.) 50x50 (0.03-mm dia.)
10 to 250 10 to 250
E32-D36P1
25 mm
Retroreflective
Transparent object detection; polarized
Free-cut
E3X-NA@ (V) E3X-NA@F E3X-NA@ (V)
35-mm dia. (0.3-mm dia.) 35-mm dia. (0.5-mm dia.) 35-mm dia. 150 (0.6-mm dia.) to 1,500 35-mm dia. 150 to (4.0-mm dia.) 1,000
E32-R21 +E39-R3 (Attachment)
10 mm
Transparent Free-cut object detection, polarized (operating ambient temperature: -25C to 55C); enclosure rating: IEC 60529 IP66
E32-R16 +E39-R1 (Attachment)
25 mm
Reflector E39-R1
E3X-NA@F
Limited reflective
Suitable for positioning crystal glass
Free-cut
E3X-NA@ (V) E3X-NA@F E3X-NA@ (V) E3X-NA@F E3X-NA@ (V) E3X-NA@F E3X-NA@ (V) E3X-NA@F E3X-NA@ (V) E3X-NA@F
4 to12 4 to12 42 42 7.21.8 7.21.8 3.3 3.3 3.3 3.3
---
E32-L56E1 E32-L56E2
35 mm
Detects Free-cut wafers and small differences in height; (operating ambient temperature: -40C to 105C); enclosure rating: IEC 60529 IP50 Detects Free-cut wafers and small differences in height; enclosure rating: IEC 60529 IP50
25x25 (0.015-mm dia.) 25x25 (0.03-mm dia.) 25x25 (0.015-mm dia.) 25x25 (0.03-mm dia.) 25x25 (0.015-mm dia.) 25x25 (0.03-mm dia.) 25x25 (0.015-mm dia.) 25x25 (0.03-mm dia.) -----
E32-L24L
10 mm
E32-L25L
E32-L25
25 mm
E32-L25A
Fluidlevel detection
Fluid contact type: unbendable section L 150 mm, 350 mm (two types) Tubemounting type
Free-cut
E3X-NA@ (V)
L
---
E32-D82F1 E32-D82F2
40 mm
E3X-NA@F E3X-NA@ (V) E3X-NA@F ---
-----
E32-L25T
10 mm
*1 Sensing distance indicates values for white paper. *2 For continuous operation, use the products within a temperature range of -40C to 130C. *3 Teflon is a registered trademark of the Dupont Company and the Mitsui Dupont Chemical Company for their fluoride resin. *4 Indicates the heat-resistant temperature at the fiber tip. Note: The values of the minimum sensing target indicate those obtained at a distance where the smallest object can be sensed with the Reflective Fiber Unit.
24
E3X-NA
E3X-NA
25
E3X-NA
E3X-NA
26
E3X-NA
E3X-NA
27
E3X-NA
E3X-NA
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.
OMRON ELECTRONICS LLC
One East Commerce Drive Schaumburg, IL 60173
OMRON ON-LINE
Global - http://www.omron.com USA - http://www.omron.com/oei Canada - http://www.omron.com/oci
OMRON CANADA, INC.
885 Milner Avenue Scarborough, Ontario M1B 5V8
1-800-55-OMRON
Cat. No. E318-E3-1
10/01/7.5M
416-286-6465
Printed in USA
Specifications subject to change without notice
28


▲Up To Search▲   

 
Price & Availability of E3X-NA8

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .