  Datasheet File OCR Text:
  specifications are subject to change without notice (30.06.1999) 1 ? ac solid state relay ? zero switching ? low-cost triac type ? rated operational current: 10 and 25 aacrms ? non-repetitive voltage: up to 650 v p ? rated operational voltage: 230 vacrms ? input ranges: 3 to 32 vdc ? insulation: opto (input-output) 4000 vacrms ? fast-on version available product description ordering key solid state relays type selection switching mode rated opera- rated operational control voltage non-rep. voltage output tional voltage current a: zero switching 24: 230 vacrms 10: 10 aacrms -d: 3 to 32 vdc 06: 650 v p t: triac 25: 25 aacrms tf: triac/fast-on terminals solid state relay switching mode rated operational voltage rated operational current control voltage non-rep. peak voltage output selection guide rated operational non-rep. voltage terminal control voltage rated operational current voltage type 10 aacrms 25 aacrms 230 vacrms 650 v p rivet terminals 3 to 32 vdc ra 2410 -d 06t ra 2425 -d 06t 230 vacrms 650 v p fast-on terminals 3 to 32 vdc ra 2410 -d 06tf ra 2425 -d 06tf general specifications operational voltage range 24 to 280 vacrms non-rep. peak voltage 3 650 v p operational frequency range 45 to 65 hz power factor 3 0.5 @ 230 vacrms approvals csa, ul ce-marking yes insulation rated insulation voltage input to output 3 4000 vacrms rated insulation voltage output to case 3 4000 vacrms insulation resistance input to output 3 10 10 w insulation resistance output to case 3 10 10 w insulation capacitance input to output 8 pf insulation capacitance output to case 25 pf industrial, 1-phase zs types ra 24.. -d 06 t, ra 24.. -d 06 tf ra 24 10 -d 06 t the triac version of the zero switching relay is an inexpen- sive solution for resistive loads. the zero switching re- lay switches on when the ac sine curve just crosses zero, and switches off when the current crosses zero.
2 specifications are subject to change without notice (30.06.1999) ra 24.. -d 06 t, ra 24.. -d 06 tf ra 24 .. -d 06t/tf control voltage range 3 to 32 vdc pick-up voltage 3 v drop-out voltage 3 1 v reverse voltage 32 vdc input impedance 1.5 kw response time pick-up 1/2 cycle response time drop-out 1/2 cycle output specifications ra 2410 -d 06 t/f ra 2425 -d 06 t/f rated operational current ac 1 10 arms 25 arms minimum operational current 20 marms 20 marms rep. overload current t=1 s 30 a p 50 a p non-rep. surge current t=20 ms 90 a p 200 a p off-state leakage current @ rated voltage and frequency 5 marms 5 marms i 2 t for fusing t=1-10 ms 40 a 2 s 200 a 2 s critical di/dt 3 10 a/s 3 10 a/s on-state voltage drop @ rated current 1.6 vrms 1.6 vrms critical dv/dt commutating 3 10 v/s 3 10 v/s critical dv/dt off-state 3 250 v/s 3 250 v/s thermal specifications ra 2410 -d 06 t/tf ra 2425 -d 06 t/tf operating temperature -20 to +70c (-4 to +158f) -20 to +70c (-4 to +158f) storage temperature -40 to +100c (-40 to +212f) -40 to +100c (-40 to +212f) junction temperature 125c ( 257f) 125c ( 257f) r th junction to case 2.5 k/w 1.8 k/w r th junction to ambient 12.5 k/w 12.5 k/w control input functional diagram mains input/load output load output/mains input wiring diagram input specifications control input line/load
specifications are subject to change without notice (30.06.1999) 3 ra 2410 .. 06 t, ra 24.. -d 06 tf ra 24 10 .. .. t/f 6.5 5.6 4.7 3.9 3 2.1 12 7.8 6.8 5.8 4.8 3.8 2.8 10 9.2 8 6.9 5.7 4.6 3.4 9 10.8 9.5 8.1 6.8 5.4 4.1 7 - 11.4 9.8 8.2 6.5 4.9 6 - - 12.2 10.2 8.1 6.1 5 - - - - 10.5 7.9 4 - - - - - 10.9 3 ------2 ------1 20 30 40 50 60 70 10 9 8 7 6 5 4 3 2 1 t a thermal resistance [k/w] power dissipa- tion [w] load current [a] ra 24 25 .. .. t/f 1.4 1.1 0.77 0.45 - - 32 1.9 1.5 1.2 0.79 0.43 - 28 2.5 2.1 1.6 1.2 0.81 0.39 24 3.3 2.8 2.3 1.8 1.3 0.8 20 4.3 3.7 3.1 2.5 2 1.4 17 5.8 5.1 4.4 3.6 2.8 2.2 14 7.6 6.7 5.7 4.8 3.8 2.9 11 10.5 9.2 7.9 6.6 5.3 4 8 - 14.4 12.3 10.3 8.2 6.2 5 - - - - 17.1 12.8 3 20 30 40 50 60 70 t a ambient temp. [ c] 25 23 20 18 15 13 10 8 5 3 load current [a] thermal resistance [k/w] power dissipa- tion [w] weight approx. 110 g housing material noryl gfn 1, black base plate aluminium potting compound polyurethane relay mounting screws m5 mounting torque 1.5 nm control terminal mounting screws/fast-on m3 x 6/6.3 x 0.8 mm mounting torque 0.5 nm power terminal mounting screws/fast-on m5 x 6/6.3 x 0.8 mm mounting torque 2.4 nm housing specifications heatsink selection dimensions ** = 0.4 mm *** = 0.5 mm ** ** *** *** *** *** ambient temp. [ c] carlo gavazzi heatsink (see accessories) no heatsink required rhs 100 assy rhs 301 assy rhs 301 f assy consult your distributor thermal resistance r th s-a > 12.5 k/w 3.0 k/w 0.8 k/w 0.25 k/w < 0.25 k/w compare the value found in the current versus temperature chart with the standard heatsink values and select the heat- sink with the next lower value. accessories protection cover heatsinks din rail adapter varistors fuses terminals ra 24.. -d 06 tf control terminal (fast-on) 6.3 x 0.8 mm power terminal (fast-on) 6.3 x 0.8 mm for further information refer to "general accessories". heatsink dimensions (load current versus ambient temperature)


▲Up To Search▲   

 
Price & Availability of RA2410-D06T

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X