our policy is one of continued research and development. we therefore reserve the right to amend, without notice, the specifications given in this document. v03, v04 and v05 series n/ ** 5.4. 042.01 4/97 l extensive range of power and orifice size options l removable coil l manifold rail for 1 to 20 valves l reduced installation height l exhaust diffuser supplied as standard l normally closed and normally open types technical data medium: compressed air, filtered, lubricated or non-lubricated. operation: poppet valve, directly actuated with spring return. mounting: through holes in sub-base, threaded on single station. port size: g 1 8 , g 1 4 or 3mm (cnomo and interface) operating pressure: up to 16 bar. see table overleaf. orifice sizes: 1,0 mm, 1,5 mm, 2,0 mm, 2,5 mm and 3,0 mm. see table overleaf. flow: see details on page 5.4.042.03 operating temperature: 30?* to + 90? supply air 30?* to + 50? ambient * consult our technical service for use below +2? response times: 8 ?15 ms materials: glass reinforced thermoplastic encapsulated coil, stainless iron armature, stainless steel tube and spring, zinc alloy (g 1 8 and cnomo) or brass (g 1 4 ) or polyester (interface base), nitrile rubber seals. ordering information to order, quote model number as indicated in the tables overleaf, e.g. v04x486l?623a for the 3/2 model with an interface base, a 2 mm orifice and a 4,5 w, 24 v d.c. coil without plug. coils can also be supplied, quote reference from table overleaf inserting the voltage code where marked *. 2/2 and 3/2 poppet valves electrically actuated g 1 8 , g 1 4 , cnomo and interface 2 1 1 2 3 2 1 2 1
symbol model type base orifice maximum operating weight coil assembly (mm) pressure (bar) (kg) without terminal box v03x286j?613a normally closed interface 1,0 10 0,20 v03x286a?1213 v03a286j?613a normally closed g 1 8 1,0 10 0,24 v03x286a?1213 v03x486j?613a normally closed interface 1,0 10 0,20 v03x286a?1213 v03x486k?613a normally closed interface 1,5 4 0,20 v03x286a?1213 v03a486j?613a normally closed g 1 8 1,0 10 0,24 v03x286a?1213 v03a486k?613a normally closed g 1 8 1,5 4 0,24 v03x286a?1213 v03y486j?613a normally closed cnomo 1,0 10 0,30 v03x286a?1213 v03y486k?613a normally closed cnomo 1,5 4 0,30 v03x286a?1213 v03x386j?613a normally open interface 1,0 10 0,20 v03x286a?1213 v03x386k?613a normally open interface 1,5 4 0,20 v03x286a?1213 v03a386j?613a normally open g 1 8 1,0 10 0,24 v03x286a?1213 v03a386k?613a normally open g 1 8 1,5 4 0,24 v03x286a?1213 n/ ** 5.4. 042.02 v03, v04, v05 series our policy is one of continued research and development. we therefore reserve the right to amend, without notice, the specifications given in this document. 4/97 symbol model type base orifice maximum operating weight coil assembly (mm) pressure (bar) (kg) without terminal box v04x286k?62*a normally closed interface 1,5 16 0,20 v04x286a?122* v04x286l?62*a normally closed interface 2,0 16 0,20 v04x286a?122* v04x286m?62*a normally closed interface 2,5 14 0,20 v04x286a?122* v04a286k?62*a normally closed g 1 8 1,5 16 0,24 v04x286a?122* v04a286l?62*a normally closed g 1 8 2,0 16 0,24 v04x286a?122* v04a286m?62*a normally closed g 1 8 2,5 14 0,24 v04x286a?122* v04b286l?42*a normally closed g 1 4 2,0 16 0,32 v04x286a?122* v04b286m?42*a normally closed g 1 4 2,5 14 0,32 v04x286a?122* v04b286n?42*a normally closed g 1 4 3,0 7 0,32 v04x286a?122* v04x486j?62*a normally closed interface 1,0 16 0,20 v04x286a?122* v04x486k?62*a normally closed interface 1,5 13 0,20 v04x286a?122* v04x486l?62*a normally closed interface 2,0 10 0,20 v04x286a?122* v04x486m?62*a normally closed interface 2,5 4 0,20 v04x286a?122* v04a486j?62*a normally closed g 1 8 1,0 16 0,24 v04x286a?122* v04a486k?62*a normally closed g 1 8 1,5 16 0,24 v04x286a?122* v04a486l?62*a normally closed g 1 8 2,0 13 0,24 v04x286a?122* v04a486m?62*a normally closed g 1 8 2,5 4 0,24 v04x286a?122* v04y486k?62*a normally closed cnomo 1,5 13 0,30 v04x286a?122* v04y486l?62*a normally closed cnomo 2,0 10 0,30 v04x286a?122* v04y486m?62*a normally closed cnomo 2,5 4 0,30 v04x286a?122* v04x386j?62*a normally open interface 1,0 16 0,20 v04x286a?122* v04x386k?62*a normally open interface 1,5 13 0,20 v04x286a?122* v04x386l?62*a normally open interface 2,0 10 0,20 v04x286a?122* v04x386m?62*a normally open interface 2,5 4 0,20 v04x286a?122* v04a386j?62*a normally open g 1 8 1,0 16 0,24 v04x286a?122* v04a386k?62*a normally open g 1 8 1,5 13 0,24 v04x286a?122* v04a386l?62*a normally open g 1 8 2,0 10 0,24 v04x286a?122* v04a386m?62*a normally open g 1 8 2,5 4 0,24 v04x286a?122* 1 2 12 10 1 2 12 10 3 12 10 1 2 1 12 10 3 2 3 12 10 1 2 1 12 10 3 2 general information v03 v04 *insert voltage code from voltage codes table page 5.4. 042.03. all models are available without manual override. change 10th digit to 1 e.g. v03x486j? 1 1*a. cnomo versions are available with a push to operate spring return manual override. change 10th digit to 3 e.g. v03x486j? 3 1*a. warning these products are intended for use in industrial compressed air systems only. do not use these products where pressures and temperatures can exceed those listed under ?echnical data? before using these products with fluids other than those specified, for non-industrial applications, life-support systems, or other applications not within published specifications, consult norgren. through misuse, age, or malfunction, components used in fluid power systems can fail in various modes. the system designer is warned to consider the failure modes of all component parts used in fluid power systems and to provide adequate safeguards to prevent personal injury or damage to equipment in the event of such failure. system designers must provide a warning to end users in the system instructional manual if protection against a failure mode cannot be adequately provided. system designers and end users are cautioned to review specific warnings found in instruction sheets packed and shipped with these products.
symbol model type base orifice maximum operating weight coil assembly (mm) pressure (bar) (kg) without plug v05x286m?63*a normally closed interface 2,5 16 0,20 v05x286a?123* v05a286m?63*a normally closed g 1 8 2,5 16 0,24 v05x286a?123* v05b286m?43*a normally closed g 1 4 2,5 16 0,32 v05x286a?123* v05b286n?43*a normally closed g 1 4 3,0 13 0,32 v05x286a?123* v05x486k?63*a normally closed interface 1,5 16 0,20 v05x286a?123* v05x486l?63*a normally closed interface 2,0 13 0,20 v05x286a?123* v05x486m?63*a normally closed interface 2,5 10 0,20 v05x286a?123* v05a486k?63*a normally closed g 1 8 1,5 16 0,24 v05x286a?123* v05a486l?63*a normally closed g 1 8 2,0 13 0,24 v05x286a?123* v05a486m?63*a normally closed g 1 8 2,5 10 0,24 v05x286a?123* v05b486l?43*a normally closed g 1 4 2,0 13 0,24 v05x286a?123* v05b486m?43*a normally closed g 1 4 2,5 10 0,24 v05x286a?123* v05y486k?63*a normally closed cnomo 1,5 16 0,30 v05x286a?123* v05y486l?63*a normally closed cnomo 2,0 13 0,30 v05x286a?123* v05y486m?63*a normally closed cnomo 2,5 10 0,30 v05x286a?123* v05x386k?63*a normally open interface 1,5 16 0,20 v05x286a?123* v05x386l?63*a normally open interface 2,0 13 0,20 v05x286a?123* v05x386m?63*a normally open interface 2,5 10 0,20 v05x286a?123* v05a386k?63*a normally open g 1 8 1,5 16 0,24 v05x286a?123* v05a386l?63*a normally open g 1 8 2,0 13 0,24 v05x286a?123* v05a386m?63*a normally open g 1 8 2,5 10 0,24 v05x286a?123* family 7mm interface mounted valve g 1 8 valve g 1 4 valve cnomo mounted valve fixed length manifold manifold/valve assemblies v03 v03x v03a v03b v03y m/p35598/? v03x ? 86 ? -h613a# v04 v04x v04a v04b v04y m/p35598/? vo4x ? 86 ? -h62*a# v05 v05x v05a v05b v05y m/p35598/? vo5x ? 86 ? -h63*a# voltage codes 6 v d.c. 1 12 v d.c. 2 24 v d.c. 3 48 v d.c. 5 110 v d.c. 7 24 v 50/60 hz 4 48 v 50/60 hz 6 110 ?120 v 50/60 hz 8 220 ?240 v 50/60 hz 9 4/97 n/ ** 5.4. 042.03 v03, v04, v05 series our policy is one of continued research and development. we therefore reserve the right to amend, without notice, the specifications given in this document. 1 2 12 10 1 12 10 3 2 3 12 10 1 2 v05 * voltage codes *insert voltage code from voltage codes table page 5.4. 042.03. all models are available without manual override. change 10th digit to 1 e.g. v03x486j? 1 1*a. cnomo versions are available with a push to operate spring return manual override. change 10th digit to 3 e.g. v03x486j? 3 1*a. *insert voltage code from table below ?insert number of stations voltage tolerance: ?0% inrush/hold v03 d.c. 1,0 w vo4 d.c. 4,5 w a.c. 14/10 va vo5 d.c. 9,0 w a.c. 27/20 va 100% e.d. plug: a variety of plugs are available, see section 7.7.001 manual override screwdriver operated, memory type, standard protection class: ip 65 (din 40 050) with terminal box fitted inlet orifice c b l/min a cv kv ? mm 1 0,15 0,61 39,4 0,95 0,04 0,03 1,5 0,30 0,36 68,95 1,26 0,07 0,06 2 0,57 0,30 137,9 2,36 0,14 0,12 2,5 0,77 0,30 187,15 3,05 0,19 0,16 3,0 1,16 0,49 275,8 6,25 0,28 0,24 flow characteristics the above figures are based on valves mounted on a g 1 8 base. they are typical of all base styles as the orifice diameter is the limiting factor. note: the v03 models are only available with the 24 v d.c. coil. technical details valve and base options
n/ ** 5.4. 042.04 v03, v04, v05 series our policy is one of continued research and development. we therefore reserve the right to amend, without notice, the specifications given in this document. 4/97 v03x, v04x and v05x models interface mounted valves ??g 1 / 8 24 4,7 24 32 7 7 9,3 41 59,5 70 2 40 69 7 6 5 2,7 2,4 3,3 7 7,5 32 ? ? 6
v03a, v04a and v05a models g 1 8 valves 24 m4 24 32 41 8 74 2 40 69 12,5 32 63,5 ?? g 1 / 8 ??g 1 / 8 ??g 1 / 8 2,4 1,5 ??g 1 / 8 6 model codes * not available on g 1 ? note: this table should be used for identification purposes only and not to build up model variants. v 0 h h h 8 - b 6 h h family substitute vo3 3 vo4 4 vo5 5 h h h base type substitute interface x cnomo y g 1 / 8 a g 1 / 4 b function substitute 2/2 normally closed 2 3/2 normally open 3 3/2 normally closed 4 inlet orifice substitute 1,0 mm (interface, cnomo) j 1,5 mm (interface, cnomo, g 1 / 8 ) k 2,0 mm (interface, cnomo, g 1 / 8, g 1 / 4 ) l 2,5 mm (interface, cnomo, g 1 / 8, g 1 / 4 ) m 3,0 mm (g 1 / 4 ) n manual operator substitute none 1 push to operate spring return 3* lever, memory type 4 screwdriver, memory type 6* power substitute 1w (vo3 models only) 1 4,5w (vo4 models only) 2 9w (vo5 models only) 3 voltage code see voltage code table on page 3 integral design all valves b solenoid operator all valves 8 spring return all valves 6 plug substitute none a standard, with pg9 cable gland b indicator, with pg9 cable gland g
4/97 n/ ** 5.4. 042.05 v03, v04, v05 series m/p35598/ * weight = n x 0,041 kg g 1 8 n = number of stations * indicates the number of stations (1 ?20) fixed length manifold 33 x (n ?) + 32 33 33 ? ? ? 16 m5 x 0,8 24 ** ** 61** 61** 4 4 ??g 1 / 8 x 9,5 61** 4 n = number of stations ** two additional holes with five or more stations our policy is one of continued research and development. we therefore reserve the right to amend, without notice, the specifications given in this document. v03b, v04b and v05b models g 1 4 valves 12,7 41 12 83 36 40 69 19 32 m4 72,5 ??g 1 / 4 ??g 1 /4 12,7 50 v03y, v04y and v05y models cnomo mounted valves ??g 1 / 8 8 41 7,5 79 2 41 70 17 68,5 33 33 21 32 21 7,5 ? ? m4 6
n/ ** 5.4. 042.06 v03, v04, v05 series our policy is one of continued research and development. we therefore reserve the right to amend, without notice, the specifications given in this document. 4/97 voltage range model number power consumption 12 ?24 v a.c./d.c. m/p40861 0,25 w 110 ?120 v a.c./d.c. m/p40880 0,25 w 220 ?240 v a.c./d.c. m/p40862 0,25 w light emitting gaskets options and accessories basic valve model manifold/valve assembly model v03x286j?613a v03x286j?613a# v03 v03x486j?613a v03x486j?613a# v03x486k?613a v03x486k?613a# vo4x286k?62*a vo4x286k?62*a# vo4x286l?62*a vo4x286l?62*a# vo4x286m?62*a vo4x286m?62*a# v04 vo4x486j?62*a vo4x486j?62*a# vo4x486k?62*a vo4x486k?62*a# vo4x486l?62*a vo4x486l?62*a# vo4x486m?62*a vo4x486m?62*a# vo5x286m?61*a vo5x286m?63*a# v05 vo5x486k?61*a vo5x486k?63*a# vo5x486l?61*a vo5x486l?63*a# ??g 1 / 8 41 59,5 95,7 69 6 17,2 33 x (n* ?) + 32 33 33 "a" view on arrow "a" ? ? ? 16 m5 24 ** ** 61** 61** 4 4 13,2 32,7 8,6 ? ??g 1 / 8 g 1 / 8 manifold/valve assemblies # insert number of stations (1 - 20 stations) 1 = 1 station 2 = 2 station a = 10 station b = 11 station k = 19 station l = 20 station * insert voltage code from page 5.4.042.03 interface mounted valves can be supplied pre-assembled on manifolds. select the basic valve required and quote the associated manifold/valve assembly model using the table below.
|