  specification model clg-60-12 clg-60-15 clg-60-20 clg-60-24 clg-60-27 c lg-60-36 clg-60-48 dc voltage current range rated power output voltage adj. range current adj. range line regulation load regulation setup time voltage range note.4 frequency range power factor (typ.) efficiency (typ.) ac current (typ.) input inrush current(max.) leakage current working temp. working humidity storage temp., humidity temp. coefficient vibration mtbf dimension others note packing over current short circuit over voltage over temperature 12v 15v 20v 24v 27v 36v 48v 0 ~ 5a 0 ~ 4a 0 ~ 3a 0 ~ 2.5a 0 ~ 2.3a 0 ~ 1.7a 0 ~ 1.3a 60w 60w 60w 60w 62.1w 61w 62.5w 2vp-p 2.4vp-p 1.8vp-p 2.7vp-p 2.7vp-p 3.6vp-p 4.6vp-p 10% fixed can be modified between the range above fixed. can be modified between 3% ~ -25% rated output current 3.0% 5.0% 3000ms / 230vac 5000ms / 115vac at full load 90 ~ 295vac 127 ~ 417vdc 47 ~ 63hz pf>0.94/115vac, pf>0.9/230vac, pf>0.9/277vac at full load (plea se refer to "power factor characteristic" curve) 85% 86% 87.5% 87% 88% 89% 89% 13.8 ~ 16v 17.5 ~ 21v 23 ~ 26v 28 ~ 32v 31 ~ 35v 41 ~ 46v 54 ~ 60v 0.8a/115vac 0.4a/230vac 40a/230vac <0.75ma / 240vac 95 ~ 110% protection type : constant current limiting, recovers automatical ly after fault condition is removed hiccup mode, recovers automatically after fault condition is remove d -30 ~ +70 (refer to "derating curve") 20 ~ 95% rh non-condensing -40 ~ +80 , 10 ~ 95% rh 0.03%/ (0 ~ 50 ) 10 ~ 500hz, 5g 12min./1cycle, period for 72min. each along x, y, z axes 495.7khrs min. mil-hdbk-217f (25 ) 195.6*61.5*38.8mm (l*w*h) 1. all parameters not specially mentioned are measured at 230vac input, r ated load and 25 of ambient temperature. 2. ripple & noise are measured at 20mhz of bandwidth by using a 12" twisted pair- wire terminated with a 0.1uf & 47uf parallel capacitor. 3. tolerance : includes set up tolerance, line regulation and load regula tion. 4. derating may be needed under low input voltage. please check the static ch aracteristics for more details. 5. constant current operation region is within 70% ~100% rated output vol tage. this is the suitable operation region for led related application s, but please reconfirm special electrical requirements for some specific syste m design. 6. the power supply is considered as a component that will be operated in comb ination with final equipment. since emc performance will be affected by t he complete installation, the final equipment manufacturers must re- qualify emc directive on the complete installation again. 7. direct connecting to leds is suggested, but is not suitable for using add itional drivers. 0.86kg; 16pcs/14.8kg/0.54cuft protection type : shut down o/p voltage, re-power on to recover 60w single output led power supply universal ac input / full rangebuilt-in active pfc function protections: short circuit / over current / over voltage / over temperature cooling by free air convection ip67 design for indoor or outdoor installations ul1310 class 2 power unit pass lps 100% full load burn-in test high reliability suitable for led lighting and moving sign applications compliance to worldwide safety regulations for lighting 3 years warranty (up to 295vac) suitable for dry / damp / wet locations (note.2) high efficiency 89% features : c l g - 6 0 s e r i e s ripple & noise (max.) note.2 voltage tolerance note.3 environment safety & emc protection 12v: 90 10 (tsw1) detect on heatsink of power transistor 15v ~ 48v: 85 10 (tsw1) detect on heatsink of power transistor protection type : shut down o/p voltage, recovers automatically after t emperature goes down file name:clg-60-spec 2011-07-28 withstand voltage isolation resistance i/p-o/p:3.75kvac i/p-fg:1.88kvac o/p-fg:0.5kvac ul879, ul8750, ul1310 class 2, tuv en61347-1, en61347-2-13 indepen dent, can/csa c22.2 no. 223-m91(except for 48v) ; j61347-1, j61347-2-13(20~27only), ip67 approved i/p-o/p:100m ohms / 500vdc / 25 / 70% rh safety standards compliance to en55015, en55022 (cispr22) class b, en61000-3-2 clas s c ( 75% load) ; en61000-3-3 compliance to en61000-4-2,3,4,5,6,8,11, en55024, en61547, lig ht industry level (surge 4kv), criteria a 10.5 ~ 15v 14 ~ 20v 16.8 ~ 24v 18.9 ~ 27v 25.2 ~ 36v 33.6 ~ 48v 8.4 ~ 12v rated current 5a 4a 3a 2.5a 2.3a 1.7a 1.3a constant current region note.5 11.5 ~ 13v 14.5 ~ 16.2v 19.5 ~ 22v 24 ~ 26v 25 ~ 30v 32.5 ~ 39v 43.6 ~ 51.8v ip67 ( for 48v only) ( except for 48v ) f m m 110 lps selv ( for 20~27v only) emc immunity emc emission
mechanical specification file name:clg-60-spec 2011-07-28 case no. 957a unit:mm derating curve static characteristics ambient temperature ( ) load (%) -30 -25 -5 0 15 30 50 60 70 20 40 60 80 100 input voltage (v) 60hz 90 100 125 135 145 155 165 175 180 200 230 295 100 90 80 70 60 50 40 load (%) (horizontal) fosc : 90khz(115vac) 120khz(230vac) 195.6 171.8 11.9 9.6 4.2 4pl 61.5 46.5 32 300 20 -v(black) 38.8 +v(red) 300 20 svt 18awg 2c sjtw 18awg 3c fg (green/yellow) ac/l(brown) ac/n(blue) detection pwm & pfc circuit o.l.p. emi filter rectifiers power switching filter & rectifiers +v -v i/p fg control o.v.p. & o.c.p. 85.9 t case 30.75 t case: max. case temperature. 60w single output led power supply c l g - 6 0 s e r i e s block diagram
36 40 44 48 52 56 60 64 68 72 76 80 84 88 92 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% 277vac 230vac 115vac 0 . 7 8 0 . 8 0 0 . 8 2 0 . 8 4 0 . 8 6 0 . 8 8 0 . 9 0 0 . 9 2 0 . 9 4 0 . 9 6 0 . 9 8 1 . 0 0 5 0 % 6 0 % 7 0 % 8 0 % 9 0 % 1 0 0 % 2 7 7 v a c 2 3 0 v a c 1 1 5 v a c clg-60 series possess superior working efficiency that up to 89% can be rea ched in field applications. efficiency (%) load power factor characteristic efficiency vs load (48v model) constant current mode pf load driving methods of led module (60w) this led power supply is suggested to work in constant current mode area (cc) t o drive the leds. typical led power supply i-v curve vo(%) 100 70 50 100 (max.) io (%) constant current area hiccup protection file name:clg-60-spec 2011-07-28 60w single output led power supply c l g - 6 0 s e r i e s


▲Up To Search▲   

 
Price & Availability of CLG-60-36

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X