pmc-24v035w1aa 35watts total power: 35watts input voltage: 85-264vac # of output: single special features - full aluminium casing for lightweight and corrosion resistant handling - universal ac input - overvoltage protection - overload protection - thermal protection - mtbf: > 700,000 hrs. - expected life time: 10 years - 2 years warranty - rohs compliant model number reference no. output (dc) output power 35w output voltage range 22 - 28v output current 1.46a (35w max.) pard (20mhz) < 150mvpp (@ nominal values) start-up time < 2500ms @ 100% load (25c) and typical line input hold-up time > 15ms @ 115vac, > 80ms @ 230vac with 35w load (25c) rise time < 30ms @ 100% load (25c) line regulation < 0.5% typical (@ 85 - 264vac input, 100% load) load regulation < 1% typical (@ 85 - 264vac input, 0 to 100% load) input (ac) input voltage range 85 - 264vac; 100 - 375vdc input frequency 47 - 63hz max. input current 1.0a max. (0.72a max. @ 115vac, 0.4a max. @ 230vac) inrush current limitation i2t (+25c) typ. < 30a @ 115vac, 60a @ 230vac effciency > 85% (typical) leakage current < 1ma @ 240vac mechanical design case cover aluminium (al1100) dimensions (l x w x h) 128mm x 97mm x 38mm unit weight / box 0.237kg mtbf > 700,000 hrs noise sound pressure level (spl) < 40dba cooling convection input / output terminal terminal block 5 pin rated 300v/20a input / output wire awg22-14 shock proof iec60068-2-27 vibration iec60068-2-6 pmc-24v035w1aa EOE11010118 panel mount power supply 24v 35w 1 phase pmc-24v035w1aa output power 35w 50w 100w output voltage range 22 - 28vdc 22 - 28vdc 22 - 28vdc output current 1.46a (35w max.) 2.1a (50w max.) 4.17a (100w max.) pard (20mhz) < 150mvpp (@ nominal values) < 150mvpp (@ nominal values) < 150mvpp (@ nominal values) start-up time < 2500ms @ 100% load (25c) and typical line input < 2500ms @ 100% load (25c) and typical line input < 1000ms @ 100% load (25c) and typical line input hold-up time > 15ms @ 115vac, > 80ms @ 230vac with 35w load (25c) > 15ms @ 115vac, > 90ms @ 230vac with 50w load (25c) > 15ms @ 115vac, > 90ms @ 230vac with 100w load (25c) rise time < 30ms @ 100% load (25c) < 30ms @ 100% load (25c) < 30ms @ 100% load (25c) line regulation < 0.5% typical (@ 85 - 264vac input, 100% load) < 0.5% typical (@ 85 - 264vac input, 100% load) < 0.5% typical (@ 85 - 264vac input, 100% load) load regulation < 1% typical (@ 85 - 264vac input, 0 to 100% load) < 1% typical (@ 85 - 264vac input, 0 to 100% load) < 1% typical (@ 85 - 264vac input, 0 to 100% load) input voltage range 85 - 264vac; 100 - 375vdc 85 - 264vac; 100 - 375vdc 85 - 264vac; 100 - 375vdc input frequency 47 - 63hz 47 - 63hz 47 - 63hz max. input current 1.0a max. (0.72a max. @ 115vac, 0.4a max. @ 230vac) 1.5a max. (1.1a max. @ 115vac, 0.7a max. @ 230vac) 3.0a max. (2.0a max. @ 115vac, 1.1a max. @ 230vac) inrush current limitation l2t (+25c) < 30a @ 115vac, 60a @ 230vac < 30a @ 115vac, 60a @ 230vac < 50a @ 115vac, 100a @ 230vac (no damage, all input effciency > 85% (typical) > 86% (typical) > 86% (typical) leakage current < 1ma @ 240vac < 1ma @ 240vac < 1ma @ 240vac case cover aluminium (al1100) aluminium (al1100) aluminium (al1100) dimensions (l x w x h) 128mm x 97mm x 38mm 128mm x 97mm x 38mm 158mm x 97mm x 38mm unit weight / box 0.237kg 0.255kg 0.410kg mtbf > 700,000 hrs. > 700,000 hrs. > 700,000 hrs. noise sound pressure level (spl) < 40 dba sound pressure level (spl) < 40 dba sound pressure level (spl) < 40 dba cooling convection convection convection input / output terminal terminal block 5 pin rated 300v/20a terminal block 5 pin rated 300v/20a terminal block 7 pin rated 300v/20a input / output wire awg22-14 awg22-14 awg22-14 shock test iec 60068-2-27 iec 60068-2-27 iec 60068-2-27 vibration iec 68000-2-6 iec 68000-2-6 iec 68000-2-6 safety / environmental emc / emissions fcc title 47, class b/ en55022;cispr22, class b fcc title 47, class b/ en55022;cispr22, class b fcc title 47, class b/ en55022;cispr22, class b immunity en 61000-4-2, 1995; en61000-4-3, 1998; en61000-4-4, 1995; iec61000-4-5, 1995; en61000-4-6, 1996; en61000-4-8 or iec61000- 4-12 or ieee c62.41; en61000-3-2, 1994 en 61000-4-2, 1995; en61000-4-3, 1998; en61000-4-4, 1995; iec61000-4-5, 1995; en61000-4-6, 1996; en61000-4-8 or iec61000- 4-12 or ieee c62.41; en61000-3-2, 1994 en 61000-4-2, 1995; en61000-4-3, 1998; en61000-4-4, 1995; iec61000-4-5, 1995; en61000-4-6, 1996; en61000-4-8 or iec61000- 4-12 or ieee c62.41; en61000-3-2, 1994 approvals ur/cur recognized to ul60950-1 and csa c22.2 no.60950-1; cb test certifcate and report to iec60950-1; ce (emc and low voltage directive), ur/cur recognized to ul60950-1 and csa c22.2 no.60950-1; cb test certifcate and report to iec60950-1; ce (emc and low voltage directive), ur/cur recognized to ul60950-1 and csa c22.2 no.60950-1; cb test certifcate and report to iec60950-1; ce (emc and low voltage directive), galvanic isolation input to output: 3 kvac; input to output: 3 kvac; input to output: 3 kvac; note (*) * operation to 70c possible * operation to 70c pos - * operation to 70c possible
delta electronics (thailand) public company limited 909 moo 4, e.p.z., bangpoo industrial estate, tambon prakasa, amphur muang samutprakarn, samutprakarn 10280, thailand tel: +662 709 2800 fax: +662 709 2827 e-mail: vl@delta.co.th www.deltaenergysystems.com l n pm c mechanical drawing safety / environmental emc / emissions fcc title 47, class b/en55022cispr22, class b immunity en 61000-4-2, 1995 en61000-4-3, 1998 en61000-4-4, 1995 iec61000-4-5, 1995 en61000-4-6, 1996 en61000-4-8 or iec61000-4-12 or ieee c62.41 en61000-3- 2, 1994 safety standard ur/cur recognied to ul60950-1 and csa c22.2 no.60950-1; cb test certifcate and panel mount power supply 24v 35w 1 phase pmc-24v035w1aa safety / environmental emc / emissions fcc title 47, class b/ en55022cispr22, class b fcc title 47, class b/ en55022cispr22, class b fcc title 47, class b/ en55022cispr22, class b immunity en 61000-4-2, 1995 en61000-4-3, 1998 en61000-4-4, 1995 iec61000-4-5, 1995 en61000-4-6, 1996 en61000-4-8 or iec61000- 4-12 or ieee c62.41 en61000-3-2, 1994 en 61000-4-2, 1995 en61000-4-3, 1998 en61000-4-4, 1995 iec61000-4-5, 1995 en61000-4-6, 1996 en61000-4-8 or iec61000- 4-12 or ieee c62.41 en61000-3-2, 1994 en 61000-4-2, 1995 en61000-4-3, 1998 en61000-4-4, 1995 iec61000-4-5, 1995 en61000-4-6, 1996 en61000-4-8 or iec61000- 4-12 or ieee c62.41 en61000-3-2, 1994 approvals ur/cur recognied to ul60950-1 and csa c22.2 no.60950-1 cb test certifcate and report test certifcate and report test certifcate and report
|