  xecom (1) xe5620 xe5620 january 2003 56 kbps surface-mountable integrated sealed-hybrid modem description xecom?s xe5620 provides a complete 56 kbps modem into an miniature, surface-mount package. xecom?s new hyplcc? package (hybrid plcc) makes it possible to meet the conflicting goals of small size, low cost and surface-mountability. the xe5620 targets remote monitoring applications in industrial, commercial and residential locations as a complete modem, the xe5620 includes not only all modem circuitry but also user transferrable fcc part 68 registration and ul60950 recognition. this allows the xe5620 to be easily integrated into your embedded application. xecom?s new hyplcc? package infuses the xe5620 with both its small size and surface mountability. the hyplcc package allows complex hybrid circuits to fit the 68-pin plcc footprint. the hyplcc? package provides a completely sealed environment protecting the xe5620 during assembly and board cleaning operations. xecom also provides a low speed model, the xe2420, in the hyplcc? package. features * small size: the hyplcc? measures less than 1 inch by 1 inch square and 0.290 inches thick * surface-mountable: the hyplcc? package is equivalent to a 68-pin plcc device. * data transfer at all rates from 300 bps to 56kbps using v.90, v.34bis, v.34, v.32bis, v.32, v.22bis, v.22, v.23, v.21, bell 212a, and bell 103 protocols * supports v.42 error correction and v.42bis data compression * modem control and configuration via industry standard at commands. * non-volatile memory stores modem configuration and permits stored number dialing. * incorporates fax send and receive capabilities controlled by class 1 fax commands. * complete integrated daa includes, ring detect, loop current holding circuit, hook switch. metallic surge protection, and solid-state daa * user transferrable fcc part 68 registration * ul60950 recognition * low power operation, 3.3 volts, 300 milliw att; xe5620 block diagram
xecom (2) xe5620 xe5620 mechanical specifications a b c d c f g e e 45 o i (top) inches millimeters dimension min typ max min typ max a 0.280 0.285 0.290 7.11 7.24 7.37 b 0.985 0.990 0.995 25.02 25.15 25.27 c 0.950 0.955 0.960 24.13 24.26 24.38 d 0.910 0.920 0.930 23.11 23.37 23.62 e 0.045 0.050 0.055 1.15 1.27 1.40 f 0.695 0.700 0.705 17.65 17.78 17.91 g 0.195 0.200 0.205 10.03 10.16 10.29 i(radius) 0.015 0.020 0.025 0.13 0.25 0.38 i i .050?
xecom (3) xe5620 xe5620 pin configuration pin descriptions pin name description 1 /dcd /dcd is an active low output from the modem. the at&c command controls when the xe5620 asserts /dcd. 2 /cts /cts is an active low output from the modem. the modem asserts /cts to indicate that it can accept data from the terminal equipment on /txd. 3 /reset reset is an active low input which initiates a modem hardware reset. reset must be active for a minimum of 100 milliseconds for a proper modem reset sequence. no external reset is required; if none is used the reset signal should be left open. 4 /dsr /dsr is an active low output from the modem. the at&s command controls when the xe5620 asserts /dsr. 5 /rts /rts is an active low input to the modem. /rts indicates to the modem that the host has data to send. 6 /dtr /dtr is an active low input to the modem. the at&d command determines how the modem will interpret activity on /dtr. 7 /rxd /rxd provides the path for received data and modem responses to be sent from the modem to the host terminal equipment. /dcd 1 /cts 2 reset 3 /dsr 4 24 ring /rts 5 23 n/c /dtr 6 22 tip /rxd 7 21 n/c /txd 8 20 n/c /ri 9 19 np gnd 10 18 np spkr 11 17 np n/c 12 16 np n/c 13 vcc 14 n/c 15 top
xecom (4) xe5620 8 /txd /txd provides the path for transmitted data and modem commands to be passed from the host terminal equipment to the modem. 9 /ri the /ri signal reports on the presence of an incoming ring signal. when a ring occurs across tip and ring, the /ri output goes low and toggles with the cadence of the ring signal.. 10 ground ground provides the reference voltage for all host interface signals. 11 spkr spkr allows connection of a speaker to monitor modem operations. spkr cannot directly drive a speaker. an amplifier with a minimum input impedance of 300 ohms is required. the signal on spkr is controlled by the atl and atm commands. 12-13 n/c no internal connection 14 vcc vcc provides 3.3 volt power to the modem. 15 n/c no internal connection 16-19 np no pin 20-21 n/c no internal connection 22 tip the ring and tip signals provide modem the connection to the telephone line. fcc part 68 rules require a 1500 volt isolation barrier between the telephone line and all other circuits. this isolation must be preserved throughout the system. the telephone company places a dc ?battery? voltage across tip and ring on all public switched telephone lines. the xe5620 will operate regardless of the polarity of this ?battery? voltage. the ?battery? voltage drives up to 100 milliamps of dc loop current. ul60950 requires minimum creepage and clearances distances be maintained between the tip and ring traces and all other circuits. clearance is the shortest distance between conductive circuits; creepage is the distance between conductive surfaces along the surface 23 n/c no internal connection, to prevent damage in case of voltage surges on the telephone line, we recommend that nothing be connected to this pin. 24 ring the ring and tip signals provide modem the connection to the telephone line. fcc part 68 rules require a 1500 volt isolation barrier between the telephone line and all other circuits. this isolation must be preserved throughout the system. the telephone company places a dc ?battery? voltage across tip and ring on all public switched telephone lines. the xe5620 will operate regardless of the polarity of this ?battery? voltage. the ?battery? voltage drives up to 100 milliamps of dc loop current. ul60950 requires minimum creepage and clearances distances be maintained between the tip and ring traces and all other circuits. clearance is the shortest distance between conductive circuits; creepage is the distance between conductive surfaces along the surface. xe5620 pin descriptions (continued) pin name description
xecom (5) xe5620 xe5620 soldering instructions the xe5620 is subject to damage if over-exposed to heat during solder reflow operations. following the soldering instructions below will ensure that the process of soldering the module to the board does not damage the modem. the xe5620 must not be exposed to direct infrared (ir) heating. if your process includes direct ir heating, you must shield the xe5620 from the infrared rays. maximum temperature 220 o c maximum time at 220 o c 20 seconds maximum time above eutectic (180 o c) 90 seconds maximum preheat dwell time 180 seconds maximum recommended solder temperature profile 220 o c 180 o c 150 o c -20 sec- --------------------------------180 sec max --------------------- max ----- 90 sec max -----
xecom (6) xe5620 xe5620 electrical specifications vcc 3.13 3.3 3.47 volts icc 85 90 100 ma on line icc 25 ma on-hook ring voltage detected 26 150 vrms type b ringer ring frequency detected 15.3 68 hz type b ringer telephone loop current 10 40 100 ma line impedance 600 ohms data transmit level -12.0 -9.0 dbm dtmf transmit level -2.5 0 dbm avg over 3 second interval voh 2.4 volts vol 0.4 volts vih 2.0 vcc+0.3 volts vil -0.3 0.8 volts parameter min typ max units comments xe5620 absolute maximum ratings storage temperature -25 o c to +85 o c operating temperature range 1 0 o c to +70 o c maximum time above eutectic (183 o c) 90 seconds preheat dwell time 120 to 180 seconds 1 the xe5620 can be ordered with an operating temperature of -40 o c to +85 o c at extra cost. order XE5620-ITR or to specify industrial temperature range (itr).
xecom (7) xe5620 xe5620 typical connection diagram notes: 1 fb1 and fb2 are ferrite beads which may be required for emi filtering in your system. without these components you may experience unintended radiation when the telephone cable is attached. we recommend selecting components such as the tdk acb2012l-120 which provide a minimum of 100 ohms of impedance at frequencies above 100 mhz. 2. c1 and c2 are high-voltage capacitors which may be required for emi filtering in your system. without these components you may experience unintended radiation when the telephone cable is attached to your system. we recommend selecting components such as the panasonic eckdrs471. this 470 pfd, 3000 volt capacitor will direct the high frequency harmonics to the system ground. these capacitors must be rated at a minimum of 1500 volts to maintain the isolation required by fcc part 68 rules. 3. f1 and f2 are positive thermal coefficient (ptc) devices which protect the modem form excessive current flow. these devices are required for your system to pass ul60950. fuses may be used in place of the ptc?s parts list for xe5620 typical connection diagram reference reference designation qty description designation qty description c1, c2 2 cap. 470 pfd 2600v fb1, fb2 2 ferrite, acb2012l-120 c3 1 cap. .1 ufd 20% 16v ls1 1 speaker, 8 ohms c4 1 cap. .1 ufd 20% 16v r1 1 potentiometer, 10k c5 2 ferrite, acb2012l-120 r2 1 resistor, 10 ohms 20 % f1, f2 2 ptc, tr600-150 u1 1 national semi lm386
xecom (8) xe5620 application note: using a 68-pin plcc socket the xe5620 can be inserted into a socket for a 68-pin plcc device. the hyplcc package uses only 20 pins; 15 on one side and 5 on the opposite side. alignment within the socket is critical for all pins of the xe5620 to make contact with the appropriate pins of the plcc socket. the drawing below illustrates how the xe5620 can be inserted into the 68-pin plcc socket. emulation technology?s s-smt-17-068-a socket is representative of sockets that can be sued with the xe5620. 60 44 61 43 1 9 27 10 26 xe5620 1 2 3 4 24 5 23 6 22 7 21 8 20 9 19 10 18 11 17 12 16 13 14 15
xecom (9) xe5620 the xe5620 uses "at" commands for configuration and control. this section describes the at command format and lists the at commands, registers and result codes. xe5620 "at" commands have two operational modes; command mode, data mode and fax mode. data mode: the xe5620 enters data mode after it connects to a remote modem and issues the appropriate result code. in the data mode the modem sends all data presented on transmit data (/txd) to the remote modem and puts data from the remote modem onto received data (/rxd). when the modem exits data mode, it issues a "no carrier" result code. command mode: the xe5620 enters command mode on power-up, reset, a lost connection, or receipt of the escape code. in command mode the modem accepts commands from the host on transmit data. appropriate result codes are returned on received data. fax mode: the xe5620 enters class 1 fax mode on receipt of at+fclass=1. in fax mode commands and responses are issued at 19,200 bits per second; the character format is 8 bits no parity. the modem accepts fax commands only in fax mode. the a/, ato, at&t and escape commands are not valid in fax mode. command line format command lines issued to the modem follow a strict format. each command begins with the prefix at. the command buffer stores the command line and executes it upon receipt of a carriage return. until executed, the command line can be edited with the backspace key. command prefix - each command, except the a/ command, begins with the at prefix. the "a" and "t" may be both upper case or both lower case but cannot be of different cases. the prefix identifies the speed and parity of the commands sent to the modem. the modem deternies data rate by measuring the width of the incoming bits. parity is determined by comparing the parity bits of the "a" and the "t." xe5620 at commands command line - commands may be strung together in a single command line of up to 36 characters. com- mands are executed in the sequence they appear. spaces may be inserted into the command line but do not fill space in the command buffer. a carriage return termi- nates the command line and causes the commands to be executed. register s3 allows the user to select a character other than a carriage return to terminate the command line. command buffer - the command buffer holds a maximum of 36 characters, including the at prefix. if the command buffer overflows, the modem issues an "error" result code and commands are not executed. command line editing - the backspace edits a command line before it is executed. the backspace key, (control and h simultaneously on some systems), erases the previous character in the command line. register s5 allows the user to select a character other than a back- space to edit the command line. re-execute last command - the a/ command causes the modem to re-execute the last command line. this is the only command which does not require the "at" prefix. omitted parameters - most commands include a pa- rameter which determines how the functions will be set. when the command parameter is omitted from the command string, it is assumed to be a 0. escape characters - a 3 character escape sequence may be entered to switch the modem into command mode while on line. the escape character, set by register s2, must be entered 3 times in succession to execute the escape. an at command must then be entered within the period defined by s12 to enter command mode. the default escape sequence is "+++." result codes - the modem issues a result code after each action. result codes may be sent as full words, one or two digit numeric codes, or may be disabled all together. each result code ends with a carriage return when numeric result codes are chosen. when full word result codes are chosen, a line feed and carriage return precede and follow each result code.
xecom (10) xe5620 xe5620 at commands an asterisk indicates the factory default a - answer command - bn - select communications standard n=0 selects ccitt standards * n=1 selects bell standards d - dial command - 0-9, a-d, #, * = dialing digits p = pulse dial t = tone dial w = wait for dial tone , = pause for the duration of s8 @ = wait for silence ! = switch hook flash ; = return to the command state ^ = enable calling tone s=n = dial stored number n en - command echo n=0 do not echo commands n=1 enable command echo* hn - switch hook control - n=0 switch hook relay opens n=1 switch hook relay closes in - modem identification l n - speaker volume - n=0 speaker volume low n=1 speaker volume low n=2 speaker volume medium * n=3 speaker volume high. m n - speaker activity - n=0 speaker off n=1 speaker on until carrier received* n=2 speaker remains on n=3 speaker on after dialing until dcd detected. nn - modulation selection n=0 communication rate set by at*i command n=1 automatic negotiation of data rate beginning at at*i setting. * on - on line n=0 return on line with no retrain* n=1 initiate retrain while returning on line. n=2 initiate rate renegotiation while returning on line. qn - responses n=0 send responses * n=1 no responses sr? - interrogate register - sr=n - set register value - vn - result codes - n=0 numeric result codes n=1 english word result codes* wn - connect result code - n=0 display connect dce speed n=1 display connect dte speed n=2 display connect dce speed plus error control extension * n=3 display connect dte speed plus error control extension xn - result code set - n=0 responses 0-4 n=1 responses 0-5 & 10 n=2 responses 0-6 & 10 n=3 responses 0-5, 7 & 10 n=4 responses 0-7 & 10* zn - reset - n=0 reset and recall profile 0 * n=1 reset and recall profile 1 &cn - dcd operation n=0 dcd is forced active n=1 dcd indicates a valid carrier signal * &dn - dtr n=0 dtr is ignored n=1 when the modem is on-line dtr off switches it to the command mode and issues ok response. n=2 modem disconnects if the host revokes dtr.* n=3 the modem performs a soft reset when dtr is revoked. &f - reset factory defaults &gn - guard timer - n=0 none * n=1 550 hz guard timer n=2 1800 hz guard timer
xecom (11) xe5620 xe5620 at commands &kn - flow control n=0 no flow control n=3 rts/cts flow control * n=4 xon/xoff flow control n=5 transparent xon/xoff flow control &pn - pu lse dial make/break ratio n=0 39%/61% 10 pps * n=1 33%/67% 10 pps n=2 39%/61% 20 pps n=3 33%/67% 20 pps &sn - data set read y n=0 data set ready forced active * n=1 data set ready on at start of modem handshake &un - protocol selection n=0 v.90 * n=1 v.34bis/v.34 n=2 v.32bis/v.22bis n=3 bell 103 n=4 v.21 n=5 v.23 &v - view active configuration &wn - store current configuration n=0 store active configuration in profile 0 * n=1 store active configuration in profile 1 &yn - select configuration to recall n=0 recall configuration profile 0 * n=1 recall configuration profile 1 &zn=x - store dialing string x %cn - data compression control n=0 no data compression n=1 data compression enabled * \nn - error control mode n=0 normal mode n=1 direct mode n=2 mnp required n=3 mnp or normal n=4 auto error correction v.42 without odp or adp phase detection, mnp or normal mode n=5 auto reliable mode * n=6 v.42 without odp or adp phase detection required n=7 v.42 with odp or adp phase detection required \vn - protocol result code n=0 no protocol result code added to response * n=1 protocol result code added to response *hn - automatic retrain n=0 automatic retrain disabled n=1 automatically retrain on poor signal quality *in - select maximum connection speed n=0 1200 bps, n=1 2400 bps, 28,000 with at&u=0 n=2 4800 bps, 29,333 with at&u=0 n=3 7200 bps, 30,666 with at&u=0 n=4 9600 bps, 32,000 with at&u=0 n=5 12,000 bps, 33,333 with at&u=0 n=6 14,400 bps, 34,666 with at&u=0 n=7 16,800 bps, 36,000 with at&u=0 n=8 19,200 bps, 37,333 with at&u=0 n=9 21,600 bps, 38,666 with at&u=0 n=10 24,000 bps, 40,000 with at&u=0 n=11 26,400 bps, 41,333 with at&u=0 n=12 28,800 bps, 42,666 with at&u=0 n=13 31,200 bps, 44,000 with at&u=0 n=14 33,600 bps *, 45,333 with at&u=0 n=15 46,666 bps with at&u=0 n=16 48,000 bps with at&u=0 n=17 49,333 bps with at&u=0 n=18 50,666 bps with at&u=0 n=19 52,000 bps with at&u=0 n=20 53,333 bps with at&u=0 n=21 54,666 bps with at&u=0 n=22 56,000 bps with at&u=0 * *hn - automatic retrain n=0 automatic retrain disabled n=1 automatically retrain on poor signal quality *
xecom (12) xe5620 xe5620 at class 1 fax commands at+fclass? - service class indication 0 = configured as a data modem 1 = configured for service class 1. at+fclass=? - service class capability 0 = configured as a data modem 1 = configured for service class 1. at+fclass=n - set service class 0 = configured as a data modem 1 = configured for service class 1. at+fae=n - data/fax auto answer 0 = answer as a fax modem only 1 = either a fax or data modem at+flo - flow control 0 = flow control off 1 = xon/xoff flow control selected 2 = rts/cts flow control selected at+frh - receive hdlc data 3 v.21 channel 2, 300 bps 24 v.27ter, 2400 bps 48 v.27ter, 4800 bps 72 v.29, 7200 bps 96 v.29, 9600 bps 97 v.17, 9600 bps 98 v.17 short train, 9600 bps 121 v.17, 12,000 bps 122 v.17 short train, 12,000 bps 145 v.17, 14,400 bps 146 v.17 short train, 14,400 bps at+frm - receive fax (see at+frh for "mod" values) at+frs


▲Up To Search▲   

 
Price & Availability of XE5620-ITR

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X