Datasheet File OCR Text: |
moeller hpl0211-2001/2002 t rotary switches, p switch-disconnectors rotary switches switch-disconnectors 07/000
07/001 moeller hpl0211-2001/2002 t rotary switches, p switch-disconnectors overview rotary switches switch-disconnectors t rotary switches, p switch-disconnectors tm mini rotary switches page page overview of functions 07/002 overview of functions 07/002 technical overview 07/004 technical overview 07/004 system overview 07/006 system overview 07/072 key to type references, modular system 07/010 key to type references, modular system 07/010 on-off switches on-off switches main switches 07/012 control circuit isolators 07/074 on-off switches 07/018 on-off switches 07/074 safety switches 07/024 control switches control switches changeover switches 07/026 changeover switches 07/075 reversing switches 07/032 reversing switches 07/082 star-delta switches 07/032 step switches 07/077 multi-speed switches 07/034 on-off switches 07/081 step switches 07/036 hand/auto switches 07/076 on-off switches 07/040 on-off switches, spring-return 07/081 hand/auto switches 07/042 coding switches 07/082 on-off switches, spring-return 07/044 group switches 07/080 universal control switches 07/046 coding switches 07/046 series switches 07/046 instrument selector switches 07/048 switches with locking arrangements panic switches 07/050 on-off switches 07/050 hand/auto switches 07/052 accessories accessories front plates 07/054 key operation 07/083 key operation 07/058 additional accessories 07/060 non-standard switches non-standard switches t0 rotary switches 07/084 tm mini rotary switches 07/088 t3 rotary switches 07/085 t5b rotary switches 07/086 t5 rotary switches 07/087 bulk packaged switches 07/088 technical data 07/090 technical data 07/095 dimensions 07/096 dimensions 07/108 ordering of non-standard switches 07/110 ordering of non-standard switches 07/110 for other standard contact sequences, see catalogue k115 moeller hpl0211-2001/2002 t rotary switches, p switch-disconnectors overview of functions rotary switches switch-disconnectors 07/002 function flush mounting .../e... centre mounting .../ez... surface mounting .../i... distribution board mounting .../ivs... rear mounting .../z... on-off switches main switches maintenance switches for use as emergency-stop devices 1) a 07/012 a 07/013 a 07/013 main switches maintenance switches with auxiliary contacts for use as emergency-stop devices 1) a 07/014 a 07/015 a 07/015 main switches maintenance switches a 07/013 a 07/013 a 07/013 main switches maintenance switches with auxiliary contacts a 07/015 a 07/015 a 07/015 on-off switches with black thumb-grip a 07/016 a 07/019 a 07/019 a 07/019 a 07/019 a 07/074 a 07/074 on-off switches with black thumb-grip with auxiliary contacts a 07/020 a 07/021 a 07/021 a 07/021 a 07/021 on-off switches for use as emergency-stop devices 1) a 07/022 a 07/023 a 07/023 control circuit isolators a 07/074 safety switches 25 ? 100 a for use as emergency-stop devices 1) a 07/024 safety switches 25 ? 100 a a 07/025 notes 1) to iec/en 60 204-1; with red thumb-grip and yellow front plate rotary switches switch-disconnectors 07/003 moeller hpl0211-2001/2002 t rotary switches, p switch-disconnectors overview of functions function flush mounting .../e... centre mounting .../ez... surface mounting .../i... distribution board mounting .../ivs... rear mounting .../z... control switches changeover switches mains transfer-, group switches a 07/026 a 07/027 a 07/027 a 07/027 a 07/027 a 07/075 a 07/075 reversing switches a 07/032 a 07/033 a 07/033 a 07/033 a 07/033 a 07/082 a 07/082 star-delta switches a 07/032 a 07/033 a 07/033 a 07/033 a 07/033 multi-speed switches a 07/034 a 07/035 a 07/035 a 07/035 a 07/035 step switches a 07/036 a 07/036 a 07/037 a 07/037 a 07/037 a 07/077 a 07/077 on-off switches, changeover switches a 07/040 a 07/040 a 07/041 a 07/041 a 07/041 a 07/081 a 07/081 hand/auto switches a 07/042 a 07/042 a 07/043 a 07/043 a 07/043 a 07/076 a 07/076 spring-return switches a 07/044 a 07/044 a 07/045 a 07/045 a 07/045 a 07/081 a 07/081 universal control switches a 07/046 a 07/046 a 07/047 a 07/047 a 07/047 coding switches a 07/046 a 07/046 a 07/047 a 07/047 a 07/047 a 07/082 a 07/082 series switches a 07/046 a 07/046 a 07/047 a 07/047 a 07/047 instrument selector switches (voltage) a 07/048 a 07/048 a 07/049 a 07/049 a 07/049 instrument selector switches (current) a 07/048 a 07/048 a 07/049 a 07/049 a 07/049 switches with locking arrangements a 07/050 a 07/051 a 07/051 moeller hpl0211-2001/2002 t rotary switches, p switch-disconnectors technical overview rotary switches switch-disconnectors 07/004 switch size tm t0 t3 t5b three-phase motor rating ac-3 220 ? 240 v kw 1.5 3 6.5 15 380 ? 440 v kw 2.2 4 12 22 690 v kw ? 4 15 22 ac-23 220 ? 240 v kw 1.8 3.5 7.5 18.5 380 ? 440 v kw 3 6.5 13 22 690 v kw ? ? ? 22 rated operational current ac-21 380 ? 440 v 3~ a 10 20 32 63 ac-15 220 ? 240 v a 2.5 6 10 16 380 ? 415 v a 1.5 4 6 6 rated uninterrupted current a 10 20 32 63 mounting form type degree of protection surface mounting 1) .../i... ip65 ? k k k .../i 45/... ? ? ? ? .../i 48/... ? ? ? ? .../st/... ? k k k surface mounting main switch 1) .../i.../svb... ip65 ? k k k .../st/svb... ? k k k flush mounting .../e... front ip65 k k k k flush mounting main switch/flush mounting control circuit isolator .../ea/svb... front ip65 ? k k k tm.../e/svb k ? ? ? centre mounting .../ez... front ip65 ? k k ? tm.../ez k ? ? ? rear mounting .../z... front ip65 ? k k k rear mounting main switches .../v/svb... front ip65 ? k k k service distribution board mounting .../ivs... front ip30 k k ? ? notes 1) enclosures for metric cable glands to en 50 262, cable glands a page 07/070 rotary switches switch-disconnectors 07/005 moeller hpl0211-2001/2002 t rotary switches, p switch-disconnectors technical overview t5 t6-2 t6-3-8212 t6-160-6 t8-3-8342 t8-3-8212 p1 p3 18.5 22 22 22 37 37 5.5 7.5 15 22 30 37 37 45 55 55 7.5 13 30 37 30 22 22 22 37 37 7.5 15 30 37 18.5 37 37 37 75 75 7 8.5 18.5 30 30 45 45 55 132 132 13 15 37 50 30 30 30 30 37 37 11 18.5 30 75 100 125 125 160 315 315 25 32 63 100 16 ? ? ? ? ? ? ? ? ? 6 ? ? ? ? ? ? ? ? ? 100 125 125 160 315 315 25 32 63 100 k ? ? ? ? ? k k ? ? ? k ? ? ? ? ? ? ? ? k ? ? ? k ? ? ? ? ? k k k ? ? ? ? ? k k k ? ? ? ? ? k k k k k ? ? k k k k k ? ? ? ? k k ? ? ? ? ? ? ? ? ? ? ? ? ? ? k ? ? ? ? ? ? ? ? ? ? ? ? ? ? k k k k ? k k ? k k ? ? ? ? ? ? k k moeller hpl0211-2001/2002 t rotary switches system overview rotary switches switch-disconnectors 07/006 t0, t3, t5b, t5 on-off switches t0, t3, t5b, t5 control switches 10 9 8 7 7 6 5 4 3 2 1 6 8 9 10 10 1 2 3 4 9 9 10 rotary switches switch-disconnectors 07/007 moeller hpl0211-2001/2002 t rotary switches system overview service distribution board mounting (.../ivs) 1 front ip30 for snap fitting to en 50 022 top-hat rail flush mounting ? service distribution boards: up to 3 contact units (45 mm mounting depth) ? control panels: up to 11 contact units a page 07/019 rear mounting (.../z) 2 front ip65 secured by screw fixing or snap fitting (t0 or t3) for snap fitting to en 50 022 top-hat rail coupling drive in door or cover connection from the front a page 07/019 rear mounting main switches (.../v/svb) 2 front ip65 to iec/en 60 204 and iec/en 60 947-3, up to 8 contacts for t0..., and up to 12 contacts for t3 with door interlock in i (on) position a page 07/013 flush mounting (.../e) 3 front ip65 fitting and connection from the rear terminal: pozidriv plus-minus screw finger and back-of-hand proof type t8 with extension terminals as standard a page 07/018 flush mounting main switches (.../ea/svb) 3 front ip65 to iec/en 60 204 and iec/en 60 947-3, up to 8 contacts for t0..., and up to 12 contacts for t3 n terminal and pe terminal a page 07/012 centre mounting (.../ez) 3 front ip65 mounting in ? 22.3 fixing hole to iec/en 60 947-5-1 centre fixing permits installation by one fitter a page 07/019 surface mounting (.../i...) 4 ip65 with pe terminal enclosures designed for metric cable glands to en 50 262 a page 07/019 surface mounting main switches (.../i...) 4 ip65 to iec/en 60 204 and iec/en 60 947-3, up to 8 contacts for t0..., and up to 10 contacts for t3 0 (off) position lockable using up to 3 padlocks enclosures designed for metric cable glands to en 50 262 with pe terminal a page 07/013 safety switches (.../i...) 5 ip65 with pe terminal with cover fixing in the 0 (off) position 0 (off) position lockable using up to 3 padlocks enclosures designed for metric cable glands to en 50 262 with ?safety switch? label colour: orange for switzerland: comply with the swiss accident insurance institute directive a page 07/024 main switch (assembly kit) for use as emergency-stop device 6 to iec/en 60 204-1 with red rotary handle and yellow locking collar lockable in the 0 (off) position a page 07/062 main switch (assembly kit) 7 black rotary handle and locking collar lockable in the 0 (off) position a page 07/062 thumb-grip for use in emergency-stop devices 8 to iec/en 60 204-1 red thumb-grip with yellow front plate a page 07/062 thumb-grip 9 black thumb-grip with front plate a page 07/062 coupling drive 10 includes push-fit shaft for retrofitting t0(t3)-.../xz basic switches in the rear mounting form spare parts for t0(t3)/(p1)-.../z for retrofit conversion of t5(b)-.../e flush mounting switches to rear mounting form spare part for t5(b)-.../z a page 07/066 moeller hpl0211-2001/2002 p switch-disconnectors system overview rotary switches switch-disconnectors 07/008 p1, p3 on-off switches 11 10 10 9 9 8 7 7 5 3 2 1 4 4 1 6 8 11 rotary switches switch-disconnectors 07/009 moeller hpl0211-2001/2002 p switch-disconnectors system overview service distribution board mounting (.../ivs) 1 front ip30 fitting dimensions to din 43 880 for snap fitting to en 50 022 top-hat rail space requirement p1, 3-pole: 3 space units p3, 3-pole: 4 space units p3-.../ivs can be locked in 0 (off) position using the padlocking feature a page 07/019 rear mounting (.../z) 2 front ip65 secured by snap fitting or screw fixing for snap fitting to en 50 022 top-hat rail coupling drive in door or cover connection from the front 2 add-on modules can be fitted (or retrofitted) a page 07/019 rear mounting main switches (.../v/svb) 2 front ip65 to iec/en 60 204 and iec/en 60 947-3 with door interlock in i (on) position maintenance key for commissioning or fault tracing 0 (off) position lockable using up to 3 padlocks 2 add-on modules can be fitted (or retrofitted) a page 07/013 flush mounting (.../e) 3 front ip65 fitting and connection from the rear terminal: pozidriv plus-minus screw finger and back-of-hand proof 2 add-on modules can be fitted (or retrofitted) a page 07/018 flush mounting main switches (.../ea/svb) 3 front ip65 to iec/en 60 204 and iec/en 60 947-3 n terminal and pe terminal 0 (off) position lockable using up to 3 padlocks 2 add-on modules can be fitted (or retrofitted) a page 07/012 centre mounting (.../ez) 3 front ip65 mounting in ? 22.3 fixing hole to iec/en 60 947-5-1 centre fixing permits installation by one fitter a page 07/019 add-on modules 4 switched neutral (early-make contact) hi 11 auxiliary contact = 1 make contact + 1 break contact finger-proof auxiliary make contact: always connected as load-shedding contact (late-make, early-break) a page 07/064 surface mounting (.../i...) 5 ip65 with pe terminal add-on modules for retrofitting: p1: + 1, p3: + 2 enclosures designed for metric cable glands to en 50 262 a page 07/019 surface mounting main switches (.../i...) 5 ip65 with pe terminal to iec/en 60 204 and iec/en 60 947-3 0 (off) position lockable using up to 3 padlocks add-on modules for retrofitting: p1: + 1, p3: + 2 enclosures designed for metric cable glands to en 50 262 a page 07/013 safety switches (.../i...-si) 6 ip65 with pe terminal with cover fixing in the 0 (off) position 0 (off) position lockable using up to 3 padlocks with ?safety switch? label colour: orange enclosures designed for metric cable glands to en 50 262 for switzerland: comply with the swiss accident insurance institute directive a page 07/024 main switch (assembly kit) for use as emergency-stop device 7 to iec/en 60 204-1 with red rotary handle and yellow locking collar lockable in the 0 (off) position a page 07/062 main switch (assembly kit) 8 black rotary handle and locking collar lockable in the 0 (off) position a page 07/062 thumb-grip for use in emergency-stop devices 9 to iec/en 60 204-1 red thumb-grip with yellow front plate a page 07/062 thumb-grip 10 black thumb-grip with front plate a page 07/062 coupling drive 11 includes push-fit shaft for retrofitting t0(t3)-.../xz basic switches in the rear mounting form spare parts for t0(t3)/(p1)-.../z for retrofit conversion of t5(b)-.../e flush mounting switches to rear mounting form spare part for t5(b)-.../z a page 07/066 moeller hpl0211-2001/2002 t rotary switches, p switch-disconnectors key to type references, modular system rotary switches switch-disconnectors 07/010 using the modular system to convert the mounting form using the modular system to convert the mounting form of t5(b) rotary switches are suitable for many different switching and control functions, e.g. as on-off switches, main switches, main circuit/auxiliary circuit control switches, instrument selector switches. the switches consist of a handle, basic switch and mounting accessories. the contact chamber (contact unit) contains 1 or 2 contacts. our ?t rotary switches? catalogue, k115, shows more than 800 often used standard contact sequences (available on request). on the following pages, you will find a selection of the standard contact sequences we offer. t rotary switches and p switch-disconnectors are manufactured without pcb, cfc, asbestos or silicon. the contacts are cadmium-free. the ci-k insulated enclosures do not contain silicon technical data for ci-k small enclosures: a see instal- lation equipment catalogue, hpl0212-2000gb t0 and t3 rotary switches key to type references t . . . . . . . . . . . . - . . . . . . . . . . . . . . . . . . . . . . . . . . . . - . . . . . . . . . . . . . . . . . . . . . . . / . . . . . . . . . . . . . . . . . . . . + . . . . . . . . . . . . . . . . . . + . . . . . . . . . . . . . . . . . . switch size t0 or t3 number of contact chambers = contact units contact sequence number mounting form a page 07/004 front plate type (if different from list type) a page 07/054 accessories a page 07/056 t5(b) rotary switches key to type references t . . . . . . . . . . . . - . . . . . . . . . . . . . . . . . . . . . . . . . . . . - . . . . . . . . . . . . . . . . . . . . . . . / . . . . . . . . . . . . . . . . . . . . + . . . . . . . . . . . . . . . . . . + . . . . . . . . . . . . . . . . . . switch size t5(b) number of contact chambers = contact units contact sequence number mounting form a page 07/004 front plate type (if different from list type) a page 07/054 accessories a page 07/054 notes types preceded by ? +... ? are additions to the basic type and cannot be ordered separately. 1) includes shaft ci-k1-t0 ci-k2-t3 t0-.../i1 1) t3-.../i2 1) t0.../ivs 1) t0(3).../e t0(3).../ez ez-t0 v/ea/svb-t0 t0(3).../xz ivs-t0 de-t0 t0(3).../z 1) v/ea/svb-t0 t0-1-(t3-1-).../v/svb . . . t0-4-(t3-1-).../v/svb t0-1-(t3-1-).../ea/svb . . . t0-4-(t3-6-).../ea/svb ci-k4-t5b ci-k5-t5 de-p3 v/ea/svb-t5 t5(b)...e t5(b).../ea/svb t5(b).../z v/ea/svb-t5 t5(b).../v/svb t5b-.../i4 t5-.../i5 svb-p3 t5b-.../i4/svb t5-.../i5/svb rotary switches switch-disconnectors 07/011 moeller hpl0211-2001/2002 t rotary switches, p switch-disconnectors key to type references, modular system the modular system offers add-on functions p1 and p3 switch-disconnectors key to type references p . . . . . . . . . . . . - . . . . . . . . . . . . . . . . . . . . . . . . . . . . / . . . . . . . . . . . . . . . . . . . . - . . . . . . . . . . . . . . . . . . / . . . . . . . . . . . . . . . . . . switch size p1 or p3 rated uninterrupted current mounting form a page 07/005 type suffix (if required) accessories a page 07/056 tm mini rotary switches the tm rotary switch requires very little space due to its exceptionally small dimensions. it is particularly well suited for switching the low voltages and low currents which occur in electronic control panels, for example. the gold-plated contacts provide extra reli- ability and safety. tm mini rotary switches have consecutive terminal markings, beginning with 1. key to type references tm-. . . . . . . . . . . . . . . . . . . . . . . . . - . . . . . . . . . . . . . . . . . . . . . . . / . . . . . . . . . . . . . . . . . . . . + . . . . . . . . . . . . . . . . . . number of contact chambers = contact units contact sequence number mounting form a page 07/074 accessories a page 07/083 circuit diagrams on pages 07/012 ? 053 and 07/074 ? 082 example: (see also ordering example on page 07/111) switch position 1: contact 1 ? 2 open, contact 3 ? 4 closed. switching from 1 to 2: contact 1 ? 2 closes with early make, contact 3 ? 4 opens with late break. switching from 2 to 3: contact 1 ? 2 opens briefly. switching from 3 to 4: contact 1 ? 2 remains closed, automatic return from 4 to 3. n-p...e or n-p...z hi 11-p1/p3e or hi 11-p1/p3z 3-pole basic unit .../e oder .../z switched neutral can be fitted left or right (for p1.../i: left only) auxiliary contact can be fitted left or right (for p1.../i: left only) terminal shroud can be fitted at top and bottom n + pe terminals also as cover interlock on .../z-switches. h-p... uv-p... 1 2 3 4 terminal marking link 1 2 3 4 0 1 2 contact open contact closed switch position 0 1 2 3 4 moeller hpl0211-2001/2002 t rotary switches, p switch-disconnectors main switches, maintenance switches rotary switches switch-disconnectors rotary switches switch-disconnectors moeller hpl0211-2001/2002 t rotary switches, p switch-disconnectors main switches, maintenance switches for use as emergency-stop device 1) without emergency-stop function 2) circuit diagram front plate no. main contacts auxiliary contacts max. three-phase motor rating (per set of 3 contacts) 50?60 hz rated uninter- rupted current flush mounting front ip65 surface mounting 3) ip65 rear mounting front ip65 flush mounting front ip65 surface mounting 3) ip65 rear mounting front ip65 no. of poles ac-3 220 v 230 v 240 v 380 v 400 v 440 v 660 v 690 v i u basic type for ... insert mounting form mounting form article no. price see price list mounting form article no. price see price list mounting form article no. price see price list mounting form article no. price see price list mounting form article no. price see price list mounting form article no. price see price list m mbkwkwkw a main switches 1 001 1.3? 20 t0-1-8200/... ea/svb 053110 i1/svb 207145 v/svb 057856 ea/svb-sw 055483 i1/svb-sw 207146 v/svb-sw 060229 1.8 3.6 ? 32 t3-1-8200/... ea/svb 066576 i2/svb 207200 v/svb 007255 ea/svb-sw 068949 i2/svb-sw 207201 v/svb-sw 004882 57.3? 63 t5b-1-8200/... ea/svb 094279 i4/svb 207240 v/svb 094273 ea/svb-sw 094278 i4/svb-sw 207241 v/svb-sw 094272 7.3 12.3 ? 100 t5-1-8200/... ea/svb 097224 i5/svb 207275 v/svb 097222 ea/svb-sw 097223 i5/svb-sw 207276 v/svb-sw 097221 2 002.22.2? 20 t0-1-102/... ea/svb 091078 i1/svb 207143 v/svb 095824 ea/svb-sw 093451 i1/svb-sw 207144 v/svb-sw 022330 35.5? 32 t3-1-102/... ea/svb 014374 i2/svb 207198 v/svb 019120 ea/svb-sw 016747 i2/svb-sw 207199 v/svb-sw 021493 7.5 11 ? 63 t5b-1-102/... ea/svb 094469 i4/svb 207238 v/svb 094463 ea/svb-sw 094468 i4/svb-sw 207239 v/svb-sw 094462 11 18.5 ? 100 t5-1-102/... ea/svb 098808 i5/svb 207273 v/svb 098806 ea/svb-sw 098807 i5/svb-sw 207274 v/svb-sw 098805 3 00344 20 t0-2-1/... ea/svb 038873 i1/svb 207147 v/svb 043619 ea/svb-sw 041246 i1/svb-sw 207148 v/svb-sw 045992 5.5 7.5 7.5 25 p1-25/... ea/svb 041097 i2/svb 207293 v/svb 055335 ea/svb-sw 048365 i2/svb-sw 207294 v/svb-sw 050738 7.5 13 15 32 p1-32/... ea/svb 081438 i2/svb 207314 v/svb 095676 ea/svb-sw 053111 i2/svb-sw 207315 v/svb-sw 055484 15 30 30 63 p3-63/... ea/svb 031607 i4/svb 207343 v/svb 048218 ea/svb-sw 057857 i4/svb-sw 207344 v/svb-sw 060230 22 37 37 100 p3-100/... ea/svb 074320 i5/svb 207373 v/svb 088558 ea/svb-sw 062603 i5/svb-sw 207374 v/svb-sw 064976 22 37 22 125 t6-2/... ea/svb 012679 ? v/svb 015052 ea/svb-sw 067349 ? v/svb-sw 069722 3+n 0 0 3 4 4 20 t0-2-8900/... ea/svb 207400 i1/svb 207151 v/svb 207405 ea/svb-sw 207401 i1/svb-sw 207152 v/svb-sw 207406 5.5 7.5 7.5 25 p1-25/... ea/svb/n 081587 i2/svb/n 207298 v/svb/n 086333 ea/svb-sw/n 083960 i2/svb-sw/n 207296 v/svb-sw/n 088706 7.5 13 15 32 p1-32/... ea/svb/n 091079 i2/svb/n 207319 v/svb/n 095825 ea/svb-sw/n 093452 i2/svb-sw/n 207317 v/svb-sw/n 098198 15 30 30 63 p3-63/... ea/svb/n 010398 i4/svb/n 207349 v/svb/n 015144 ea/svb-sw/n 012771 i4/svb-sw/n 207346 v/svb-sw/n 017517 22 37 37 100 p3-100/... ea/svb/n 019890 i5/svb/n 207379 v/svb/n 024636 ea/svb-sw/n 022263 i5/svb-sw/n 207376 v/svb-sw/n 027009 6 00344 20 t0-3-8342/... ea/svb 029382 i1/svb 207159 v/svb 034128 ea/svb-sw 031755 i1/svb-sw 207160 v/svb-sw 036501 6.5 12 15 32 t3-3-8342/... ea/svb 071326 i2/svb 207208 v/svb 076072 ea/svb-sw 073699 i2/svb-sw 207209 v/svb-sw 078445 15 22 22 63 t5b-3-8342/... ea/svb 092308 i4/svb 207242 v/svb 092300 ea/svb-sw 092307 i4/svb-sw 207243 v/svb-sw 092299 18.5 30 30 100 t5-3-8342/... ea/svb 096383 i5/svb 207279 v/svb 096381 ea/svb-sw 096382 i5/svb-sw 207280 v/svb-sw 096380 8 00344 20 t0-4-8344/... ea/svb 008267 i1/svb 207163 v/svb 014007 ea/svb-sw 008268 i1/svb-sw 207164 v/svb-sw 008272 6.5 12 15 32 t3-4-8344/... ea/svb 008964 i2/svb 207212 v/svb 020598 ea/svb-sw 008965 i2/svb-sw 207213 v/svb-sw 008967 15 22 22 63 t5b-4-8344/... ea/svb 092062 i4/svb 207248 v/svb 092056 ea/svb-sw 092061 i4/svb-sw 207249 v/svb-sw 092055 22 30 30 100 4) t5-4-8344/... ea/svb 095961 i5/svb 207283 v/svb 095959 ea/svb-sw 095960 i5/svb-sw 207284 v/svb-sw 095958 standard pack: 1 off standard pack: 1 off notes 1) to iec/en 60 204-1; with red rotary handle and yellow locking collar, lockable in 0 (off) position 2) with black rotary handle and locking collar, lockable in 0 (off) position 3) enclosure designed for metric cable glands to en 50 262, cable glands a page 07/070 4) t5-4-8344/i5... max. 95 a fs 908 on off 1 2 1 2 3 4 1 3 5 2 4 6 2 1 3 4 5 6 7 8 2 1 3 4 5 6 n n 2 1 3 4 5 6 7 8 9 10 12 11 2 1 3 4 5 6 7 8 9 10 12 11 13 14 16 15 07/012 07/013 moeller hpl0211-2001/2002 t rotary switches, p switch-disconnectors main switches with auxiliary contacts, maintenance switches rotary switches switch-disconnectors rotary switches switch-disconnectors moeller hpl0211-2001/2002 t rotary switches, p switch-disconnectors main switches with auxiliary contacts, maintenance switches for use as emergency-stop device 1) without emergency-stop function 2) circuit diagram front plate no. main contacts auxiliary contacts max. three-phase motor rating (per set of 3contacts) 50?60 hz rated uninter- rupted current flush mounting front ip65 surface mounting 4) ip65 rear mounting front ip65 flush mounting front ip65 surface mounting 4) ip65 rear mounting front ip65 no. of poles ac-3 220 v 230 v 240 v 380 v 400 v 440 v 660 v 690 v i u basic type for ... insert mounting form mounting form article no. price see price list mounting form article no. price see price list mounting form article no. price see price list mounting form article no. price see price list mounting form article no. price see price list mounting form article no. price see price list mmbkwkwkwa main switches with auxiliary contacts 31034420 t0-2-15679/... ea/svb 081588 i1/svb 207149 v/svb 086334 ea/svb-sw 083961 i1/svb-sw 207150 v/svb-sw 088707 3 115.57.57.5 25 p1-25/... ea/svb/hi11 091080 i2/svb/hi11 207297 v/svb/hi11 095826 ea/svb-sw/hi11 070194 i2/svb-sw/hi11 207295 v/svb-sw/hi11 098199 7.5 13 15 32 p1-32/... ea/svb/hi11 072567 i2/svb/hi11 207318 v/svb/hi11 015145 ea/svb-sw/hi11 012772 i2/svb-sw/hi11 207316 v/svb-sw/hi11 017518 15 30 30 63 p3-63/... ea/svb/hi11 019891 i4/svb/hi11 207348 v/svb/hi11 024637 ea/svb-sw/hi11 022264 i4/svb-sw/hi11 207345 v/svb-sw/hi11 027010 22 37 37 100 p3-100/... ea/svb/hi11 029383 i5/svb/hi11 207378 v/svb/hi11 034129 ea/svb-sw/hi11 031756 i5/svb-sw/hi11 207375 v/svb-sw/hi11 036502 32134420 t0-3-15683/... ea/svb 015571 i1/svb 207157 v/svb 015634 ea/svb-sw 015600 i1/svb-sw 207158 v/svb-sw 015664 6.5 12 15 32 t3-3-15683/... ea/svb 040478 i2/svb 207206 v/svb 045224 ea/svb-sw 042851 i2/svb-sw 207207 v/svb-sw 047597 3+n 1 1 3 4 4 20 t0-3-15680/... ea/svb 038875 i1/svb 207153 v/svb 043621 ea/svb-sw 041248 i1/svb-sw 207154 v/svb-sw 045994 6.5 12 15 32 t3-3-15680/... ea/svb 012002 i2/svb 207202 v/svb 016748 ea/svb-sw 014375 i2/svb-sw 207203 v/svb-sw 019121 3+n 1 1 5.5 7.5 7.5 25 p1-25/... ea/svb/n/hi11 048367 ? v/svb/n/hi11 053113 ea/svb-sw/n/hi11 050740 ? v/svb-sw/n/hi11 055486 7.5 13 15 32 p1-32/... ea/svb/n/hi11 057859 ? v/svb/n/hi11 062605 ea/svb-sw/n/hi11 060232 ? v/svb-sw/n/hi11 064978 15 30 30 63 p3-63/... ea/svb/n/hi11 067351 i4/svb/n/hi11 207350 v/svb/n/hi11 072097 ea/svb-sw/n/hi11 069724 i4/svb-sw/n/hi11 207347 v/svb-sw/n/hi11 074470 22 37 37 100 p3-100/... ea/svb/n/hi11 076843 i5/svb/n/hi11 207380 v/svb/n/hi11 081589 ea/svb-sw/n/hi11 079216 i5/svb-sw/n/hi11 207377 v/svb-sw/n/hi11 083962 3+n 1 1 3 4 4 20 t0-3-15681/... ea/svb 086335 i1/svb 207155 v/svb 091081 ea/svb-sw 088708 i1/svb-sw 207156 v/svb-sw 093454 6.5 12 15 32 t3-3-15681/... ea/svb 026240 i2/svb 207204 v/svb 030986 ea/svb-sw 028613 i2/svb-sw 207205 v/svb-sw 033359 15 22 22 63 t5b-3-8901/... ea/svb 207420 i4/svb 207244 v/svb 207422 ea/svb-sw 207421 i4/svb-sw 207245 v/svb-sw 207423 18.5 30 30 100 t5-3-8901/... ea/svb 207408 i5/svb 207277 v/svb 207410 ea/svb-sw 207409 i5/svb-sw 207278 v/svb-sw 207411 61134420 t0-4-15682/... ea/svb 019892 i1/svb 207161 v/svb 024638 ea/svb-sw 022265 i1/svb-sw 207162 v/svb-sw 027011 6.5 12 15 32 t3-4-15682/... ea/svb 054716 i2/svb 207210 v/svb 059462 ea/svb-sw 057089 i2/svb-sw 207211 v/svb-sw 061835 15 22 22 63 t5b-4-15682/... ea/svb 207425 i4/svb 207246 v/svb 207427 ea/svb-sw 207426 i4/svb-sw 207247 v/svb-sw 207428 18.5 30 30 100 t5-4-15682/... ea/svb 207413 i5/svb 207281 v/svb 207415 ea/svb-sw 207414 i5/svb-sw 207282 v/svb-sw 207416 611224222160 t6-160-6/... ? i45/svb/hi11 5) 201448 v/svb/hi11 200619 ? i45/svb-sw/hi11 5) 201447 v/svb-sw/hi11 200127 37 55 37 315 3) t8-3-8342/... ? i48/svb/hi11 6) 201450 v/svb/hi11 200620 ? i48/svb-sw/hi11 6) 201449 v/svb-sw/hi11 200128 standard pack: 1 off standard pack: 1 off notes 1) to iec/en 60 204-1; with red rotary handle and yellow locking collar, lockable in 0 (off) position 2) with black rotary handle and locking collar, lockable in 0 (off) position 3) enclosed version, up to 275 a 4) enclosure designed for metric cable glands to en 50 262, cable glands a page 07/070 5) enclosures without flanges, with k95/1n/br 6) with ks4-ci and k150/1/br fs 908 on off 2 1 3 4 5 6 7 8 2 1 3 4 5 6 13 14 22 21 l2 l3 l1 2 1 3 4 5 6 7 8 9 10 12 11 l2 l3 n l1 2 1 3 4 5 6 7 8 9 10 12 11 n 2 1 3 4 5 6 13 21 14 22 l2 l3 n l1 l2 l3 n l1 2 1 3 4 5 6 7 8 9 10 12 11 2 1 3 4 5 6 7 8 9 10 12 11 13 14 16 15 2 1 3 4 5 6 7 8 9 10 12 11 13 14 22 21 07/014 07/015 moeller hpl0211-2001/2002 t rotary switches, p switch-disconnectors main switches, maintenance switches in sheet steel enclosures rotary switches switch-disconnectors rotary switches switch-disconnectors moeller hpl0211-2001/2002 t rotary switches, p switch-disconnectors main switches, maintenance switches in sheet steel enclosures for use as emergency-stop device 1) without emergency-stop function 2) circuit diagram front plate no. main contacts auxiliary contacts max. three-phase motor rating (per set of 3contacts) 50?60 hz rated uninter- rupted current surface mounting ip65 surface mounting ip65 no. of poles ac-3 220 v 230 v 240 v 380 v 400 v 440 v 660 v 690 v i u basic type for ... insert mounting form mounting form article no. price see price list mounting form article no. price see price list mmbkwkwkwa main switches in sheet steel enclosures 30034420 t0-2-1/... st/svb 025528 st/svb-sw 201713 5.5 7.5 7.5 25 p1-25/... st/svb 025523 st/svb-sw 201714 7.5 13 15 32 p1-32/... st/svb 025522 st/svb-sw 201715 15 30 30 63 p3-63/... st/svb 025521 st/svb-sw 201716 22 37 37 100 p3-100/... st/svb 025520 st/svb-sw 201717 main switches with auxiliary contacts 61134420 t0-4-15682/... st/svb 025527 st/svb-sw 201718 6.5 12 15 32 t3-4-15682/... st/svb 025526 st/svb-sw 201719 15 22 22 63 t5b-4-15682/... st/svb 215328 st/svb-sw 215329 18.5 30 30 100 t5-4-15682/... st/svb 215330 st/svb-sw 215331 standard pack: 1 off standard pack: 1 off notes 1) to iec/en 60 204-1; with red rotary handle and yellow locking collar, lockable in 0 (off) position 2) with black rotary handle and locking collar, lockable in 0 (off) position fs 908 on off 1 3 5 2 4 6 2 1 3 4 5 6 7 8 9 10 12 11 13 14 16 15 07/016 07/017 moeller hpl0211-2001/2002 t rotary switches, p switch-disconnectors on-off switches rotary switches switch-disconnectors rotary switches switch-disconnectors moeller hpl0211-2001/2002 t rotary switches, p switch-disconnectors on-off switches circuit diagram front plate no. main contacts auxiliary contacts max. three-phase motor rating (per set of 3 contacts) 50?60 hz rated uninter- rupted current flush mounting front ip65 centre mounting front ip65 surface mounting 2) ip65 service distribution board mounting front ip30 rear mounting front ip65 no. of poles ac-3 220 v 230 v 240 v 380 v 400 v 440 v 660 v 690 v i u basic type for ... insert mounting form mounting form article no. price see price list mounting form article no. price see price list mounting form article no. price see price list mounting form article no. price see price list mounting form article no. price see price list m mbkwkwkw a on-off switches 1) 1 001 1.3? 20 t0-1-8200/... e 067352 ez 069725 i1 207074 ivs 074471 z 076844 1.8 3.6 ? 32 t3-1-8200/... e 064208 ez 066581 i2 207167 ? z 071327 57.3? 63 t5b-1-8200/... e 094281 ? i4 207218 ? z 094270 7.3 12.3 ? 100 t5-1-8200/... e 097226 ? i5 207264 ? z 097219 2 002.22.2? 20 t0-1-102/... e 088709 ez 091082 i1 207061 ivs 015147 z 095828 35.5? 32 t3-1-102/... e 076073 ez 078446 i2 207165 ? z 083192 7.5 11 ? 63 t5b-1-102/... e 094471 ? i4 207215 ? z 094460 11 18.5 ? 100 t5-1-102/... e 098810 ? i5 207262 ? z 098803 3 00344 20 t0-2-1/... e 024639 ez 027012 i1 207081 ivs 031758 z 036504 5.5 7.5 7.5 25 p1-25/... e 038724 ez 041250 i2 207299 ivs 052962 z 057708 7.5 13 15 32 p1-32/... e 079065 ez 048369 i2 207320 ivs 093303 z 098049 15 30 30 63 p3-63/... e 026861 ? i4 207356 ivs 041099 z 050591 22 37 37 100 p3-100/... e 067201 ? i5 207381 ivs 081439 z 090931 22 37 22 125 t6-2/... e 098106 ? ? ? ? 3+n 0 0 3 4 4 20 t0-2-8900/... e 207398 ez 207402 i1 207109 ivs 207403 z 207407 5.5 7.5 7.5 25 p1-25/... e/n 076845 ez/n 079218 i2/n 207303 ivs/n 083964 z/n 088710 7.5 13 15 32 p1-32/... e/n 093456 ez/n 095829 i2/n 207324 ivs/n 010402 z/n 015148 15 30 30 63 p3-63/... e/n 019894 ? i4/n 207360 ivs/n 022267 z/n 027013 22 37 37 100 p3-100/... e/n 031759 ? i5/n 207385 ivs/n 034132 z/n 038878 6 00344 20 t0-3-8342/... e 043624 ez 045997 i1 207131 ivs 050743 z 055489 6.5 12 15 32 t3-3-8342/... e 045225 ez 047598 i2 207187 ? z 052344 15 22 22 63 t5b-3-8342/... e 092310 ? i4 207226 ? z 092297 18.5 30 30 100 t5-3-8342/... e 096385 ? i5 207267 ? z 096378 8 00344 20 t0-4-8344/... e 014000 ez 014002 i1 207139 ivs 014006 z 014009 6.5 12 ? 32 t3-4-8344/... e 020593 ez 020595 i2 207194 ? z 020600 15 22 22 63 t5b-4-8344/... e 092064 ? i4 207233 ? z 092053 22 30 30 100 3) t5-4-8344/... e 095963 ? i5 207272 ? z 095956 standard pack: 1 off standard pack: 1 off notes 1) with black thumb-grip and grey front plate 2) enclosure designed for metric cable glands to en 50 262, cable glands a page 07/070 3) t5-4-8344/i5 up to 95 a fs 908 on off 1 2 1 2 3 4 1 3 5 2 4 6 2 1 3 4 5 6 7 8 2 1 3 4 5 6 n n 2 1 3 4 5 6 n n 2 1 3 4 5 6 7 8 9 10 12 11 2 1 3 4 5 6 7 8 9 10 12 11 13 14 16 15 07/018 07/019 moeller hpl0211-2001/2002 t rotary switches, p switch-disconnectors on-off switches with auxiliary contacts rotary switches switch-disconnectors rotary switches switch-disconnectors moeller hpl0211-2001/2002 t rotary switches, p switch-disconnectors on-off switches with auxiliary contacts circuit diagram front plate no. main contacts auxiliary contacts max. three-phase motor rating (per set of 3 contacts) 50?60 hz rated uninter- rupted current flush mounting front ip65 centre mounting front ip65 surface mounting 2) ip65 service distribution board mounting front ip30 rear mounting front ip65 no. of poles ac-3 220 v 230 v 240 v 380 v 400 v 440 v 660 v 690 v i u basic type for ... insert mounting form mounting form article no. price see price list mounting form article no. price see price list mounting form article no. price see price list mounting form article no. price see price list mounting form article no. price see price list m mbkwkwkw a on-off switches with auxiliary contacts 1) 3 10344 20 t0-2-15679/... e 029387 ez 031760 i1 207094 ivs 036506 z 041252 3 1 1 5.5 7.5 7.5 25 p1-25/... e/hi11 045998 ez/hi11 048371 i2/hi11 207302 ivs/hi11 053117 z/hi11 057863 7.5 13 15 32 p1-32/... e/hi11 062609 ez/hi11 064982 i2/hi11 207323 ivs/hi11 069728 z/hi11 074474 15 30 30 63 p3-63/... e/hi11 079220 ? i4/hi11 207359 ivs/hi11 081593 z/hi11 086339 22 37 37 100 p3-100/... e/hi11 069574 ? i5/hi11 207384 ivs/hi11 091085 z/hi11 093304 3 21344 20 t0-3-15683/... e 016619 ez 016658 i1 207118 ivs 016722 z 016843 6.5 12 15 32 t3-3-15683/... e 014377 ez 040480 i2 207182 ? z 019123 6 11344 20 t0-4-15682/... e 010405 ez 012778 i1 207135 ivs 017524 z 022270 6.5 12 15 32 t3-4-15682/... e 023869 ez 026242 i2 207190 ? z 030988 15 22 22 63 t5b-4-15682/... e 207424 ? i4 207229 ? z 207429 18.5 30 30 100 t5-4-15682/... e 207412 ? i5 207269 ? z 207417 standard pack: 1 off standard pack: 1 off notes 1) with black thumb-grip and grey front plate 2) enclosure designed for metric cable glands to en 50 262, cable glands a page 07/070 fs 908 on off 2 1 3 4 5 6 7 8 2 1 3 4 5 6 13 14 22 21 l2 l3 l1 2 1 3 4 5 6 7 8 9 10 12 11 2 1 3 4 5 6 7 8 9 10 12 11 13 14 16 15 07/020 07/021 moeller hpl0211-2001/2002 t rotary switches, p switch-disconnectors on-off switches rotary switches switch-disconnectors rotary switches switch-disconnectors moeller hpl0211-2001/2002 t rotary switches, p switch-disconnectors on-off switches circuit diagram front plate no. main contacts auxiliary contacts max. three-phase motor rating (per set of 3 contacts) 50?60 hz rated uninter- rupted current flush mounting front ip65 surface mounting 2) ip65 service distribution board mounting front ip30 no. of poles ac-3 220 v 230 v 240 v 380 v 400 v 440 v 660 v 690 v i u basic type for ... insert mounting form mounting form article no. price see price list mounting form article no. price see price list mounting form article no. price see price list m mbkwkwkw a on-off switches for use as emergency-stop devices 1) 1 001 1.3? 20 t0-1-8200/... e-rt 009474 i1-rt 207075 ivs-rt 081956 1.8 3.6 ? 32 t3-1-8200/... e-rt 017025 i2-rt 207168 ? 57.3 ? 63 t5b-1-8200/... e-rt 094280 i4-rt 207219 ? 7.3 12.3 ? 100 t5-1-8200/... e-rt 097225 i5-rt 207265 ? 2002.22.2 ? 20 t0-1-102/... e-rt 009046 i1-rt 207062 ivs-rt 079583 35.5 ? 32 t3-1-102/... e-rt 016318 i2-rt 207166 ? 7.5 11 ? 63 t5b-1-102/... e-rt 094470 i4-rt 207216 ? 11 18.5 ? 100 t5-1-102/... e-rt 098809 i5-rt 207263 ? 3 00344 20 t0-2-1/... e-rt 011082 i1-rt 207082 ivs-rt 084329 5.5 7.5 7.5 25 p1-25/... e-rt 002388 i2-rt 207300 ivs-rt 013140 7.5 13 15 32 p1-32/... e-rt 003197 i2-rt 207321 ivs-rt 022632 15 30 30 63 p3-63/... e-rt 005743 i4-rt 207357 ivs-rt 045845 22 37 37 100 p3-100/... e-rt 007189 i5-rt 207382 ivs-rt 086185 3+n 0 0 3 4 4 20 t0-2-8900/... e-rt 207399 i1-rt 207110 ivs-rt 207404 5.5 7.5 7.5 25 p1-25/... e-rt/n 002425 i2-rt/n 207301 ivs-rt/n 017886 7.5 13 15 32 p1-32/... e-rt/n 004555 i2-rt/n 207322 ivs-rt/n 027378 15 30 30 63 p3-63/... e-rt/n 007136 i4-rt/n 207358 ivs-rt/n 041616 22 37 37 100 p3-100/... e-rt/n 007280 i5-rt/n 207383 ivs-rt/n 034497 standard pack: 1 off standard pack: 1 off notes 1) to iec/en 60 204-1; with red thumb-grip and yellow front plate 2) enclosure designed for metric cable glands to en 50 262, cable glands a page 07/070 fs 908 ge 1 0 1 2 1 2 3 4 1 3 5 2 4 6 2 1 3 4 5 6 7 8 2 1 3 4 5 6 n n 07/022 07/023 moeller hpl0211-2001/2002 t rotary switches, p switch-disconnectors safety switches rotary switches switch-disconnectors rotary switches switch-disconnectors moeller hpl0211-2001/2002 t rotary switches, p switch-disconnectors safety switches for use as emergency-stop device 1) without emergency-stop function 2) circuit diagram front plate no. main contacts auxiliary contacts max. three-phase motor rating (per set of 3 contacts) 50?60 hz rated uninter- rupted current surface mounting ip65 surface mounting 3) ip65 notes no. of poles ac-3 220 v 230 v 240 v 380 v 400 v 440 v 660 v 690 v i u type article no. price see price list type article no. price see price list mmbkwkwkwa safety switches 3 005.57.57.5 25 p1-25/i2-si 207308 p1-25/i2-si-sw 207309 padlocking feature with captive cover fixing with ?safety switch? warning plate (other languages on request) neutral conductor or hi11 auxiliary contact can also be retrofitted to p1 and p3 safety switches a page 07/065 for general information on safety switches a page 07/109 for switches in accordance with the swiss accident insurance institute directive, please contact moeller switzerland 7.5 13 15 32 p1-32/i2-si 207329 p1-32/i2-si-sw 207330 3+n 0 0 5.5 7.5 7.5 25 p1-25/i2-si/n 207312 p1-25/i2-si/n-sw 207313 7.5 13 15 32 p1-32/i2-si/n 207333 p1-32/i2-si/n-sw 207334 with auxiliary contacts 3 1 1 5.5 7.5 7.5 25 p1-25/i2-si/hi11 207310 p1-25/i2-si/hi11-sw 207311 7.5 13 15 32 p1-32/i2-si/hi11 207331 p1-32/i2-si/hi11-sw 207332 30015303063 p3-63/i4-si 207361 p3-63/i4-si-sw 207362 22 37 37 100 p3-100/i5-si 207386 p3-100/i5-si-sw 207387 3+n 0 0 15 30 30 63 p3-63/i4-si/n 207365 p3-63/i4-si/n-sw 207366 22 37 37 100 p3-100/i5-si/n 207390 p3-100/i5-si/n-sw 207391 with auxiliary contacts 3 1 1 15 30 30 63 p3-63/i4-si/hi11 207363 p3-63/i4-si/hi11-sw 207364 22 37 37 100 p3-100/i5-si/hi11 207388 p3-100/i5-si/hi11-sw 207389 60015222263 t5b-3-8342/i4-si 207250 t5b-3-8342/i4-si-sw 207251 no contacts can be retrofitted to t... rotary switches. 18.5 30 30 100 t5-3-8342/i5-si 207447 t5-3-8342/i5-si-sw 207448 with auxiliary contacts 6 1 1 15 22 22 63 t5b-4-15682/i4-si 207254 t5b-4-15682/i4-si-sw 207255 18.5 30 30 100 t5-4-15682/i5-si 207285 t5-4-15682/i5-si-sw 207286 with auxiliary contacts 6 2 0 15 22 22 63 t5b-4-8903/i4-si 207258 t5b-4-8903/i4-si-sw 207259 18.5 30 30 100 t5-4-8903/i5-si 207289 t5-4-8903/i5-si-sw 207290 standard pack: 1 off standard pack: 1 off notes 1) to iec/en 60 204 part 1; with red rotary handle and yellow locking collar, lockable in 0 (off) position with cover interlock 2) with black rotary handle and locking collar, lockable in 0 (off) position with cover interlock 3) enclosure designed for metric cable glands to en 50 262, cable glands a page 07/070 fs 908 on off 1 3 5 2 4 6 2 1 3 4 5 6 n n 2 1 3 4 5 6 13 14 22 21 1 3 5 2 4 6 2 1 3 4 5 6 n n 2 1 3 4 5 6 13 14 22 21 2 1 3 4 5 6 7 8 9 10 12 11 2 1 3 4 5 6 7 8 9 10 12 11 13 14 22 21 2 1 3 4 5 6 7 8 9 10 12 11 13 14 16 15 07/024 07/025 moeller hpl0211-2001/2002 t rotary switches control switches: changeover switches rotary switches switch-disconnectors rotary switches switch-disconnectors moeller hpl0211-2001/2002 t rotary switches control switches: changeover switches circuit diagram front plate no. max. three-phase motor rating (per set of 3 contacts) 50 ? 60 hz rated unin- terrupted current i u flush mounting front ip65 centre mounting front ip65 surface mounting 2) ip65 service distribution board mounting front ip30 rear mounting front ip65 no. of poles ac-3 220 v 230 v 240 v 380 v 400 v 440 v 660 v 690 v basic type for ... insert mounting form mounting form article no. price see price list mounting form article no. price see price list mounting form article no. price see price list mounting form article no. price see price list mounting form article no. price see price list mkwkwkwa changeover switches with 0 (off) position 1) group switches, mains transfer switches 1 1 1.3 ? 20 t0-1-8210/... e 012742 ez 048337 i1 207076 ivs 074440 z 019862 1.8 3.6 ? 32 t3-1-8210/... e 054718 ez 003072 i2 207169 ? z 057091 57.3? 63 t5b-1-8210/... e 094261 ? i4 207432 ? z 094258 2 2.2 2.2 ? 20 t0-2-8211/... e 022234 ez 053083 i1 207102 ivs 076813 z 029354 35.5? 32 t3-2-8211/... e 061837 ez 003075 i2 207178 ? z 064210 7.5 11 ? 63 t5b-2-8211/... e 093094 ? i4 207220 ? z 093082 334420 t0-3-8212/... e 029353 ez 057829 i1 207123 ivs 079186 z 036473 6.5 12 15 32 t3-3-8212/... e 068956 ez 003080 i2 207183 ? z 071329 15 22 22 63 t5b-3-8212/... e 092386 ? i4 207223 ? z 092383 18.5 30 30 100 t5-3-8212/... e 096466 ? i5 207266 ? z 096464 3223722125 t6-3-8212/... e/hi12 214781 ? ? ? ? 37 55 37 315 t8-3-8212/... e/hi12 214782 ? ? ? ? 434420 t0-4-8213/... e 031726 ez 062575 i1 207136 ivs 081559 z 043592 6.5 12 15 32 t3-4-8213/... e 076075 ez 003079 i2 207191 ? z 078448 15 22 22 63 t5b-4-8213/... e 092112 ? i4 207230 ? z 092109 18.5 30 30 100 t5-4-8213/... e 096014 ? i5 207270 ? z 096012 434420 t0-4-8294/... e 010371 ez 072069 i1 207138 ivs 043594 z 048347 6.5 12 15 32 t3-4-8294/... e 002513 ez 001014 i2 207193 ? z 004886 15 22 22 63 t5b-4-8294/... e 092084 ? i4 207232 ? z 092081 18.5 30 22 100 t5-4-8294/... e 095986 ? i5 207433 ? z 095984 4 6.5 12 15 32 t3-4-8902/... e 215222 ez 215223 i2 215224 ? z 215225 15 22 22 63 t5b-4-8902/... e 207430 ? i4 207237 ? z 207431 18.5 30 22 100 t5-4-8902/... e 207418 ? i5 207214 ? z 207419 standard pack: 1 off standard pack: 1 off notes 1) with black thumb-grip and grey front plate 2) enclosure designed for metric cable glands to en 50 262, cable glands a page 07/070 2 0 1 2 1 3 4 fs 684 0 12 2 0 1 2 1 3 4 5 6 7 8 fs 684 0 12 2 0 1 2 13 4 5 6 7 8 9 10 11 12 fs 684 0 12 2 13 4 5 6 7 8 9 10 11 12 11 12 101 102 103 104 105 106 2 0 1 fs 684 0 12 2 0 1 2 1 3 4 5 6 7 8 9 10 11 12 13 15 16 14 fs 684 0 12 2 0 1 2 1 3 4 5 6 7 8 9 10 11 12 13 15 16 14 fs 953 0 1 2 2 1 3 4 5 6 7 8 9 10 11 12 13 15 16 14 emergency supply 0 mains 0 fs 161629 netz not- strom 07/026 07/027 moeller hpl0211-2001/2002 t rotary switches control switches: changeover switches rotary switches switch-disconnectors rotary switches switch-disconnectors moeller hpl0211-2001/2002 t rotary switches control switches: changeover switches circuit diagram front plate no. max. three-phase motor rating (per set of 3 contacts) 50?60 hz rated uninter- rupted current i u flush mounting front ip65 centre mounting front ip65 surface mounting 2) ip65 service distribution board mounting front ip30 rear mounting front ip65 no. of poles ac-3 220 v 230 v 240 v 380 v 400 v 440 v 660 v 690 v basic type for ... insert mounting form mounting form article no. price see price list mounting form article no. price see price list mounting form article no. price see price list mounting form article no. price see price list mounting form article no. price see price list m kwkwkw a changeover switches with 0 (off) position 1) with spring-return from both directions to 0 111.3?20 t0-1-8214/... e 019863 ez 076815 i1 207077 ivs 045967 z 050720 1.8 3.6 ? 32 t3-1-8214/... e 009632 ez 001073 i2 207170 ? z 012005 22.22.2?20 t0-2-8215/... e 022236 ez 081561 i1 207103 ivs 048340 z 053093 35.5? 32 t3-2-8215/... e 016751 ez 001074 i2 207179 ? z 019124 3 344 20 t0-3-8216/... e 024609 ez 086307 i1 207434 ivs 050713 z 055466 6.5 12 15 32 t3-3-8216/... e 023870 ez 001077 i2 207184 ? z 026243 standard pack: 1 off standard pack: 1 off notes 1) with black thumb-grip and grey front plate 2) enclosure designed for metric cable glands to en 50 262, cable glands a page 07/070 fs 4011 0 12 2 1 0 2 1 3 4 1 0 2 2 1 3 4 5 6 7 8 1 0 2 2 13 4 5 6 7 8 9 10 11 12 07/028 07/029 moeller hpl0211-2001/2002 t rotary switches control switches: changeover switches rotary switches switch-disconnectors rotary switches switch-disconnectors moeller hpl0211-2001/2002 t rotary switches control switches: changeover switches circuit diagram front plate no. max. three-phase motor rating (per set of 3 contacts) 50?60 hz rated uninter- rupted current i u flush mounting front ip65 centre mounting front ip65 surface mounting 2) ip65 service distribution board mounting front ip30 rear mounting front ip65 no. of poles ac-3 220 v 230 v 240 v 380 v 400 v 440 v 660 v 690 v basic type for ... insert mounting form mounting form article no. price see price list mounting form article no. price see price list mounting form article no. price see price list mounting form article no. price see price list mounting form article no. price see price list m kwkwkw a changeover switches without 0 (off) position 1) changeover switches 11.11.3?20 t0-1-8220/... e 031728 ez 095799 i1 207078 ivs 055459 z 086312 1.8 3.6 ? 32 t3-1-8220/... e 038108 ez 001018 i2 207171 ? z 040481 22.22.2?20 t0-2-8221/... e 038847 ez 010372 i1 207104 ivs 057832 z 074450 35.5? 32 t3-2-8221/... e 045227 ez 001025 i2 207180 ? z 047600 7.5 11 ? 63 t5b-2-8221/... e 093047 ? i4 207221 ? z 093044 3 344 20 t0-3-8222/... e 048339 ez 015118 i1 207124 ivs 060205 z 088686 6.5 12 15 32 t3-3-8222/... e 052346 ez 001069 i2 207185 ? z 057092 15 22 22 63 t5b-3-8222/... e 092378 ? i4 207224 ? z 092375 4 344 20 t0-4-8223/... e 050712 ez 019864 i1 207137 ivs 062578 z 086315 6.5 12 15 32 t3-4-8223/... e 059465 ez 001070 i2 207192 ? z 061838 15 22 22 63 t5b-4-8223/... e 092108 ? i4 207231 ? z 092105 18.5 30 30 100 t5-4-8223/... e 096010 ? i5 207271 ? z 096008 5 344 20 t0-5-8369/... e 060204 ez 024610 ? ivs 064951 z 098180 6.5 12 15 32 t3-5-8369/... e 066584 ez 004503 i2 207536 ? z 068957 6 344 20 t0-6-8370/... e 062577 ez 029356 ? ivs 067324 z 010380 6.5 12 15 32 t3-6-8370/... e 073703 ez 004506 ? ? z 078449 8 344 20 t0-8-8372/... e 064950 ez 034102 ? ivs 069697 z 012753 6.5 12 15 32 t3-8-8372/... e 080822 ez 004508 ? z 083195 standard pack: 1 off standard pack: 1 off notes 1) with black thumb-grip and grey front plate 2) enclosure designed for metric cable glands to en 50 262, cable glands a page 07/070 1 2 fs 943 1 2 2 1 3 4 1 2 2 1 3 4 5 6 7 8 1 2 2 13 4 5 6 7 8 9 10 11 12 1 2 2 1 3 4 5 6 7 8 9 10 11 12 13 15 16 14 1 2 2 1 3 4 5 6 7 8 9 10 11 12 13 15 16 14 17 19 20 18 1 2 2 13 4 5 6 7 8 9 10 11 12 13 15 16 14 17 19 20 18 21 22 24 23 1 2 2 13 4 5 6 7 8 9 10 11 12 13 15 16 14 17 19 20 18 21 22 24 23 25 27 29 31 26 28 30 32 07/030 07/031 moeller hpl0211-2001/2002 t rotary switches control switches: reversing switches, star-delta switches rotary switches switch-disconnectors rotary switches switch-disconnectors moeller hpl0211-2001/2002 t rotary switches control switches: reversing switches, star-delta switches circuit diagram front plate no. max. three-phase motor rating (per set of 3contacts) 50?60 hz rated unin- terrupted current i u flush mounting front ip65 centre mounting front ip65 surface mounting 2) ip65 service distribution board mounting front ip30 rear mounting front ip65 no. of poles ac-3 220 v 230 v 240 v 380 v 400 v 440 v 660 v 690 v basic type for ... insert mounting form mounting form article no. price see price list mounting form article no. price see price list mounting form article no. price see price list mounting form article no. price see price list mounting form article no. price see price list m kwkwkw a reversing switches with 0 (off) position 1) 22.22.2?20 t0-2-8400/... e 053079 ez 055452 i1 207111 ivs 060198 z 062571 35.5? 32 t3-2-8400/... e 073695 ez 000687 i2 207181 ? z 095060 7.5 11 ? 63 t5b-2-8400/... e 092918 ? i4 207222 ? z 092915 3 344 20 t0-3-8401/... e 091047 ez 093420 i1 207132 ivs 098166 z 010366 6.5 12 15 32 t3-3-8401/... e 030992 ez 000694 i2 207188 ? z 035739 15 22 22 63 t5b-3-8401/... e 092296 ? i4 207227 ? z 092293 18.5 30 30 100 t5-3-8401/... e 096376 ? i5 207268 ? z 096374 with spring-return from both directions to 0 3 344 20 t0-3-8228/... e 015112 ez 048334 i1 207125 ivs 062572 z 074437 6.5 12 15 32 t3-3-8228/... e 002538 ez 000695 i2 207186 ? z 004911 15 22 22 63 t5b-3-8228/... e 092374 ? i4 207225 ? z 092371 star-delta switches 1) 345.55.520 t0-4-8410/... e 024604 ez 053080 i1 207140 ivs 064945 z 083929 7.5 18.5 22 32 t3-4-8410/... e 009657 ez 000721 i2 207195 ? z 012030 22 37 37 63 t5b-4-8410-/... e 092052 ? i4 207234 ? z 092049 reversing star-delta switches 1) two-way switches 345.55.520 t0-5-15876/... e 000893 ez 000900 ? ivs 000902 z 000942 7.5 18.5 22 32 t3-5-15876/... e 016776 ez 000797 i2 207537 ? z 019149 3 223037 63 t5b-5-15876/... e 214785 ? ? ? z 214786 standard pack: 1 off standard pack: 1 off notes 1) with black thumb-grip and grey front plate 2) enclosure designed for metric cable glands to en 50 262, cable glands a page 07/070 2 0 1 2 13 4 5 6 7 8 fs 684 0 12 2 0 1 135 246 7 8 9 10 fs 684 0 12 1 0 2 135 246 7 8 9 10 fs 4011 0 12 y 0 2 1 3 4 5 6 7 8 9 10 11 13 15 12 14 16 fs 635 y 0 y y 0 2 1 3 4 5 6 7 8 9 11 13 15 17 19 10 12 14 16 18 20 fs 638 y 0 y y y 0 2 1 3 4 5 6 7 8 9 11 13 15 17 19 10 12 14 16 18 20 fs 4017 y 0 y 07/032 07/033 moeller hpl0211-2001/2002 t rotary switches control switches: multi-speed switches, reversing multi-speed switches rotary switches switch-disconnectors rotary switches switch-disconnectors moeller hpl0211-2001/2002 t rotary switches control switches: multi-speed switches, reversing multi-speed switches circuit diagram front plate no. max. three-phase motor rating (per set of 3 contacts) 50?60 hz rated unin- terrupted current i u flush mounting front ip65 centre mounting front ip65 surface mounting 2) ip65 service distribution board mounting front ip30 rear mounting front ip65 no. of poles ac-3 220 v 230 v 240 v 380 v 400 v 440 v 660 v 690 v basic type for ... insert mounting form mounting form article no. price see price list mounting form article no. price see price list mounting form article no. price see price list mounting form article no. price see price list mounting form article no. price see price list mkwkwkwa multi-speed switches 1) two-speed, non reversing for 2 separate windings 334420 t0-3-8451/... e 038849 ez 083936 i1 207133 ivs 026985 z 043596 6.5 12 15 32 t3-3-8451/... e 028641 ez 000956 i2 207189 ? z 031014 15 22 22 63 t5b-3-8451/... e 092288 ? i4 207228 ? z 092285 for one tapped winding 334420 t0-4-8440/... e 041222 ez 088682 i1 207141 ivs 029358 z 048342 6.5 12 15 32 t3-4-8440/... e 035760 ez 000959 i2 207196 ? z 038133 15 22 22 63 t5b-4-8440/... e 092032 ? i4 207235 ? z 092029 334420 t0-4-8441/... e 043595 ez 093428 i1 207142 ivs 031731 z 053088 6.5 12 15 32 t3-4-8441/... e 042879 ez 000960 i2 207197 ? z 045252 15 22 22 63 t5b-4-8441/... e 092028 ? i4 207236 ? z 092025 reversing multi-speed switches 1) two-speed, two directions for one tapped winding 334420 t0-6-15866/... e 055460 ez 012747 ? ivs 036477 z 067326 6.5 12 15 32 t3-6-15866/... e 054744 ez 000964 ? ? z 057117 315222263 t5b-7-15866/... e 214788 ? ? ? z 214789 standard pack: 1 off standard pack: 1 off notes 1) with black thumb-grip and grey front plate 2) enclosure designed for metric cable glands to en 50 262, cable glands a page 07/070 2 1 0 2 13 4 5 6 7 8 9 10 11 12 fs 644 0 1 2 2 1 0 2 13 4 5 6 7 8 9 111315 10 12 14 16 fs 644 0 1 2 2 0 1 2 13 4 5 6 7 8 9 111315 10 12 14 16 fs 684 0 12 2 2 1 0 1 2 1 3 4 5 6 7 8 911 10 12 13 14 15 17 19 16 18 20 21 22 23 24 fs 629 1 0 1 2 2 fs 441 1 0 1 2 2 07/034 07/035 moeller hpl0211-2001/2002 t rotary switches control switches: step switches rotary switches switch-disconnectors rotary switches switch-disconnectors moeller hpl0211-2001/2002 t rotary switches control switches: step switches circuit diagram front plate no. no. of poles steps flush mounting front ip65 centre mounting front ip65 surface mounting 2) ip65 service distribution board mounting front ip30 rear mounting front ip65 notes basic type for ... insert mounting form mounting form article no. price see price list mounting form article no. price see price list mounting form article no. price see price list mounting form article no. price see price list mounting form article no. price see price list step switches 1) one contact closed per step (without overlap) with additional 0 (off) position 12 t0-1-8240/... e 034105 ez 043597 i1 207079 ivs 027076 z 060208 suitable for actuating electronic devices rated uninterrupted current i u 20 a rated operational current i e ac-15 220 ? 240 v 6 a 380 ? 415 v 4 a ac-21a 12 a dc-13 32 v per contact 10 a additional technical data a page 07/090 13 t0-2-8241/... e 050716 ez 053089 i1 207107 ivs 057835 z 062581 14 t0-2-8242/... e 067327 ez 069700 i1 207108 ivs 074446 z 076819 15 t0-3-8243/... e 081565 ez 083938 i1 207128 ivs 088684 z 091057 16 t0-3-8244/... e 095803 ez 098176 i1 207129 ivs 012749 z 015122 32 t0-3-8280/... e 034106 ez 036479 i1 207130 ivs 041225 z 043598 33 t0-5-8281/... e 048344 ez 050717 ? ivs 055463 z 057836 34 t0-6-8282/... e 062582 ez 064955 ? ivs 069701 z 072074 standard pack: 1 off standard pack: 1 off notes 1) with black thumb-grip and grey front plate 2) enclosure designed for metric cable glands to en 50 262, cable glands a page 07/070 2 13 4 fs 418 2 1 0 2 1 0 3 2 1 0 2 13 4 5 6 fs 420 2 1 0 3 3 2 1 0 4 2 13 4 5 6 7 8 fs 422 2 1 0 3 4 3 2 1 0 4 5 2 1 3 4 5 6 7 8 9 10 fs 424 2 1 0 3 4 5 3 2 1 0 4 5 6 2 13 4 5 6 7 8 11 12 10 9 fs 426 2 1 0 3 4 6 5 2 1 0 2 13 4 5 6 7 8 9 10 11 12 fs 418 2 1 0 2 1 0 3 2 1 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 fs 420 2 1 0 3 2 1 0 3 4 2 1 3 4 5 6 7 8 9 10 11 13 15 12 14 16 17 19 18 20 21 22 23 24 fs 422 2 1 0 3 4 07/036 07/037 moeller hpl0211-2001/2002 t rotary switches control switches: step switches rotary switches switch-disconnectors rotary switches switch-disconnectors moeller hpl0211-2001/2002 t rotary switches control switches: step switches circuit diagram front plate no. no. of poles steps flush mounting front ip65 centre mounting front ip65 surface mounting 2) ip65 service distribution board mounting front ip30 rear mounting front ip65 notes basic type for ... insert mounting form mounting form article no. price see price list mounting form article no. price see price list mounting form article no. price see price list mounting form article no. price see price list mounting form article no. price see price list step switches 1) one contact closed per step (without overlap) without 0 (off) position 12 t0-1-8220/... e 031728 ez 095799 i1 207078 ivs 055459 z 086312 suitable for actuating electronic devices rated uninterrupted current i u 20 a rated operational current i e ac-15 220 ? 240 v 6 a 380 ? 415 v 4 a ac-21a 12 a dc-13 32 v per contact 10 a additional technical data a page 07/090 13 t0-2-8230/... e 088685 ez 091058 i1 207105 ivs 095804 z 098177 14 t0-2-8231/... e 012750 ez 015123 i1 207106 ivs 019869 z 022242 15 t0-3-8232/... e 026988 ez 029361 i1 207126 ivs 034107 z 036480 16 t0-3-8233/... e 041226 ez 043599 i1 207127 ivs 048345 z 050718 32 t0-3-8222/... e 048339 ez 015118 i1 207124 ivs 060205 z 088686 33 t0-5-8270/... e 091059 ez 093432 ? ivs 098178 z 010378 34 t0-6-8271/... e 015124 ez 017497 ? ivs 022243 z 024616 standard pack: 1 off standard pack: 1 off notes 1) with black thumb-grip and grey front plate 2) enclosure designed for metric cable glands to en 50 262, cable glands a page 07/070 1 2 2 1 3 4 fs 943 1 2 3 2 1 2 13 4 5 6 fs 404 3 2 1 3 2 1 4 2 13 4 5 6 7 8 fs 606 2 4 1 3 3 2 1 4 5 2 1 3 4 5 6 7 8 9 10 fs 408 3 2 4 5 1 3 2 1 4 5 6 2 1 3 4 5 6 7 8 9 10 11 12 fs 410 3 2 4 5 1 6 1 2 2 13 4 5 6 7 8 9 10 11 12 fs 943 1 2 3 2 1 2 1 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 fs 404 3 2 1 2 1 3 4 2 1 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 fs 406 2 3 1 4 07/038 07/039 moeller hpl0211-2001/2002 t rotary switches control switches: on-off switches, changeover switches rotary switches switch-disconnectors rotary switches switch-disconnectors moeller hpl0211-2001/2002 t rotary switches control switches: on-off switches, changeover switches circuit diagram front plate no. no. of poles flush mounting front ip65 centre mounting front ip65 surface mounting 2) ip65 service distribution board mounting front ip30 rear mounting front ip65 notes basic type for ... insert mounting form mounting form article no. price see price list mounting form article no. price see price list mounting form article no. price see price list mounting form article no. price see price list mounting form article no. price see price list on-off switches 1) 1 t0-1-15401/... e 038854 ez 041227 i1 207067 ivs 045973 z 048346 suitable for actuating electronic devices rated uninterrupted current i u 20 a rated operational current i e ac-15 220 ? 240 v 6 a 380 ? 415 v 4 a ac-21a 12 a dc-13 32 v per contact 10 a additional technical data a page 07/090 2 t0-1-15402/... e 053092 ez 055465 i1 207068 ivs 060211 z 062584 3 t0-2-15403/... e 067330 ez 069703 i1 207088 ivs 074449 z 076822 4 t0-2-15404/... e 081568 ez 083941 i1 207089 ivs 088687 z 091060 changeover switches 1) 1 t0-1-15421/... e 095806 ez 098179 i1 207069 ivs 012752 z 015125 2 t0-2-15422/... e 019871 ez 022244 i1 207090 ivs 026990 z 029363 3 t0-3-15423/... e 034109 ez 036482 i1 207114 ivs 041228 z 043601 standard pack: 1 off standard pack: 1 off notes 1) with black thumb-grip and grey front plate 2) enclosure designed for metric cable glands to en 50 262, cable glands a page 07/070 0 1 2 1 fs 415 0 1 0 1 2 1 4 3 fs 415 0 1 0 1 2 13 4 5 6 fs 415 0 1 0 1 2 1 3 4 5 6 7 8 fs 415 0 1 1 0 2 2 1 3 4 fs 429 0 2 1 1 0 2 2 1 3 4 5 6 7 8 fs 429 0 2 1 1 0 2 2 13 4 5 6 7 8 9 10 11 12 fs 429 0 2 1 07/040 07/041 moeller hpl0211-2001/2002 t rotary switches control switches: hand/auto switches rotary switches switch-disconnectors rotary switches switch-disconnectors moeller hpl0211-2001/2002 t rotary switches control switches: hand/auto switches circuit diagram front plate no. no. of poles flush mounting front ip65 centre mounting front ip65 surface mounting 2) ip65 service distribution board mounting front ip30 rear mounting front ip65 notes basic type for ... insert mounting form mounting form article no. price see price list mounting form article no. price see price list mounting form article no. price see price list mounting form article no. price see price list mounting form article no. price see price list hand/auto switches 1) hand/auto switches with locking arrangement a page 07/052 with 0 (off) position 1 t0-1-15431/... e 019872 ez 022245 i1 207070 ivs 026991 z 029364 suitable for actuating electronic devices rated uninterrupted current i u 20 a rated operational current i e ac-15 220 ? 240 v 6 a 380 ? 415 v 4 a ac-21a 12 a dc-13 32 v per contact 10 a additional technical data a page 07/090 2 t0-2-15432/... e 034110 ez 036483 i1 207091 ivs 041229 z 043602 3 t0-3-15433/... e 048348 ez 050721 i1 207115 ivs 055467 z 057840 with spring-return from hand 1 t0-1-15434/... e 062586 ez 018053 i1 207071 ivs 069705 z 072078 2 t0-2-15435/... e 003191 ez 003192 i1 218971 ivs 003195 z 003196 with spring-return from start 1 t0-2-15907/... e 066931 ez 069304 i1 207095 ivs 076423 z 078796 without 0 (off) position 1 t0-1-15451/... e 076824 ez 079197 i1 207072 ivs 083943 z 086316 2 t0-2-15452/... e 091062 ez 093435 i1 207092 ivs 098181 z 010381 3 t0-3-15453/... e 015127 ez 017500 i1 207116 ivs 022246 z 024619 standard pack: 1 off standard pack: 1 off notes 1) with black thumb-grip and grey front plate 2) enclosure designed for metric cable glands to en 50 262, cable glands a page 07/070 0 auto hand 2 1 3 4 fs 1401 0 hand auto 0 auto hand 2 1 3 4 5 6 7 8 fs 1401 0 hand auto 0 auto hand 2 13 4 5 6 7 8 9 10 11 12 fs 1401 0 hand auto 0 hand auto 2 1 3 4 fs 1414000 0 hand auto 0 auto hand 2 13 4 5 6 7 8 fs 1414000 0 hand auto 0 auto start hand 2 1 3 4 5 6 7 8 fs 1413890 0 auto hand start hand auto 2 1 3 4 fs 19334 hand auto hand auto 2 1 3 4 5 6 7 8 fs 19334 hand auto hand auto 2 13 4 5 6 7 8 9 10 11 12 fs 19334 hand auto 07/042 07/043 moeller hpl0211-2001/2002 t rotary switches control switches: spring-return switches rotary switches switch-disconnectors rotary switches switch-disconnectors moeller hpl0211-2001/2002 t rotary switches control switches: spring-return switches circuit diagram front plate no. no. of poles flush mounting front ip65 centre mounting front ip65 surface mounting 2) ip65 service distribution board mounting front ip30 rear mounting front ip65 notes basic type for ... insert mounting form mounting form article no. price see price list mounting form article no. price see price list mounting form article no. price see price list mounting form article no. price see price list mounting form article no. price see price list on-switch (make contact) 1) spring-return from position 1 1 t0-1-15321/... e 086317 ez 088690 i1 207064 ivs 093436 z 095809 suitable for actuating electronic devices rated uninterrupted current i u 20 a rated operational current i e ac-15 220 ? 240 v 6 a 380 ? 415 v 4 a ac-21a 12 a dc-13 32 v per contact 10 a additional technical data a page 07/090 2 t0-1-15322/... e 010382 ez 012755 i1 207065 ivs 017501 z 019874 3 t0-2-15323/... e 024620 ez 026993 i1 207087 ivs 031739 z 034112 on-off switch 1) spring-return from positions 0 and 1 1 t0-1-15366/... e 081572 ez 083945 i1 207066 ivs 088691 z 091064 on-off switch 1) spring-return from start 1 t0-1-15511/... e 019875 ez 022248 i1 207073 ivs 026994 z 029367 2 t0-2-15512/... e 034113 ez 036486 i1 207093 ivs 041232 z 043605 3 t0-3-15513/... e 048351 ez 050724 i1 207117 ivs 055470 z 057843 see k115 t0-2-8177/... e 015130 ez 017503 i1 207101 ivs 022249 z 024622 standard pack: 1 off standard pack: 1 off notes 1) with black thumb-grip and grey front plate 2) enclosure designed for metric cable glands to en 50 262, cable glands a page 07/070 1 2 1 fs 4721 1 1 2 1 4 3 fs 4721 1 1 2 13 4 5 6 fs 4721 1 1 0 2 1 3 4 fs 456 0 1 1 0 start 2 1 3 4 fs 147767 start 1 0 1 0 start 2 1 3 4 5 6 7 8 fs 147767 start 1 0 1 0 start 2 13 4 5 6 7 8 9 10 11 12 fs 147767 start 1 0 2 1 0 start start 2 1 3 4 5 6 7 8 fs 140660 0 12 start start 07/044 07/045 moeller hpl0211-2001/2002 t rotary switches control switches: universal control switches, coding switches, series switches rotary switches switch-disconnectors rotary switches switch-disconnectors moeller hpl0211-2001/2002 t rotary switches control switches: universal control switches, coding switches, series switches circuit diagram front plate no. no. of poles flush mounting front ip65 centre mounting front ip65 surface mounting 2) ip65 service distribution board mounting front ip30 rear mounting front ip65 notes basic type for ... insert mounting form mounting form article no. price see price list mounting form article no. price see price list mounting form article no. price see price list mounting form article no. price see price list mounting form article no. price see price list universal control switches 1) stay-put switches with 3 positions 1 contact closed in each position; in addition: 1 contact closed in positions 0 and 1 1 contact closed in positions 0 and 2 1 contact closed in positions 1 and 2 ? t0-3-15391/... e 029365 ez 031738 i1 207112 ivs 036484 z 038857 suitable for actuating electronic devices rated uninterrupted current i u 20 a rated operational current i e ac-15 220 ? 240 v 6 a 380 ? 415 v 4 a ac-21a 12 a dc-13 32 v per contact 10 a additional technical data a page 07/090 as above, but with spring-return from positions 1 and 2 ? t0-3-15394/... e 072079 ez 074452 i1 207113 ivs 079198 z 081571 coding switches 1) with complete rotation in both directions dual bcd code t0-4-15602/... e 029368 ez 031741 i1 207134 ivs 036487 z 038860 series switches 1) with 0 (off) position (heater switches) 1 t0-1-91/... e 072082 ez 074455 i1 207080 ivs 079201 z 081574 standard pack: 1 off standard pack: 1 off notes 1) with black thumb-grip and grey front plate 2) enclosure designed for metric cable glands to en 50 262, cable glands a page 07/070 2 0 1 2 1 3 4 5 6 7 8 9 10 12 11 fs 429 0 2 1 2 0 1 2 1 3 4 5 6 7 8 9 10 12 11 fs 458 0 1 2 9 8 7 6 5 4 3 2 1 0 2 13 4 5 6 7 8 9 11 13 15 10 12 14 16 4 2 0 3 9 6 8 15 7 fs 312 2 1 0 2 1 4 3 fs 614 0 2 1 07/046 07/047 moeller hpl0211-2001/2002 t rotary switches control switches: instrument selector switches rotary switches switch-disconnectors rotary switches switch-disconnectors moeller hpl0211-2001/2002 t rotary switches control switches: instrument selector switches circuit diagram front plate no. no. of poles flush mounting front ip65 centre mounting front ip65 surface mounting 2) ip65 service distribution board mounting front ip30 rear mounting front ip65 notes basic type for ... insert mounting form mounting form article no. price see price list mounting form article no. price see price list mounting form article no. price see price list mounting form article no. price see price list mounting form article no. price see price list voltmeter selector switches 1) 3 x phase to phase with 0 (off) position t0-2-15920/... e 038861 ez 041234 i1 207098 ivs 029452 z 048353 suitable for actuating electronic devices rated uninterrupted current i u 20 a rated operational current i e ac-15 220 ? 240 v 6 a 380 ? 415 v 4 a ac-21a 12 a dc-13 32 v per contact 10 a additional technical data a page 07/090 3 x phase to phase without 0 (off) position t0-2-15922/... e 053099 ez 055472 i1 207100 ivs 060218 z 062591 3 x phase to n with 0 (off) position t0-2-15921/... e 067337 ez 069710 i1 207099 ivs 074456 z 076829 3 x phase to phase + 3 x phase to n with 0 (off) position t0-3-8007/... e 095813 ez 098186 i1 207120 ivs 012759 z 015132 3 x phase to phase + 3 x phase to n without 0 position with complete rotation in both directions t0-3-15924/... e 019878 ez 022251 i1 207119 ivs 026997 z 029370 ammeter selector switches 1) with complete rotation in both directions measurement via current transformers with 0 (off) position t0-3-8048/... e 034116 ez 036489 i1 207122 ivs 041235 z 043608 voltmeter and ammeter selector switches 1) with complete rotation in both directions measurement via current transformers (for other circuits a catalogue k115) with 0 (off) position t0-3-8030/... e 013401 ez 013402 i1 207121 ivs 013404 z 013406 standard pack: 1 off standard pack: 1 off notes 1) with black thumb-grip and grey front plate 2) enclosure designed for metric cable glands to en 50 262, cable glands a page 07/070 0 l3+l1 l2+l3 l1+l2 2 1 3 4 5 6 7 8 l1-l2 l2-l3 l3-l1 0 fs 1410755 l3-l1 l2-l3 l1-l2 2 1 3 4 5 6 7 8 l1-l2 l2-l3 l3-l1 fs 164854 0 l3-n l2-n l1-n 2 1 3 4 5 6 7 8 l1-n l2-n l3-n fs 1410757 0 0 l3-n l2-n l1-n l1-l2 l2-l3 l3-l1 2 13 4 5 6 7 8 911 10 12 l1-l2 fs 1410759 0 l2-l3 l3-l1 l1-n l2-n l3-n l3-n l2-n l1-n l3-l1 l2-l3 l1-l2 2 13 4 5 6 7 8 911 10 12 l1-l2 l2-l3 l3-l1 l1-n l2-n l3-n fs 164721 0 l3 l2 l1 2 13 4 5 6 7 8 9 10 12 11 l1 l2 fs 9440 0 l3 0 2 0 1 2 13 4 5 6 7 8 9 10 12 11 fs 928 1 2 00 07/048 07/049 moeller hpl0211-2001/2002 t rotary switches, p switch-disconnectors switches with locking arrangements rotary switches switch-disconnectors rotary switches switch-disconnectors moeller hpl0211-2001/2002 t rotary switches, p switch-disconnectors switches with locking arrangements circuit diagram front plate no. no. of poles max. three-phase motor rating (per set of 3contacts) 50?60 hz rated uninter- rupted current flush mounting ip65 surface mounting 3) ip65 rear mounting ip65 notes ac-3 220 v 230 v 240 v 380 v 400 v 440 v 660 v 690 v i u type article no. price see price list type article no. price see price list type article no. price see price list kw kw kw a std. pack switches with locking arrangements, kms1 lock mechanism panic switches without emergency-stop function 1) with sva cylinder lock key withdrawable in positions 0 and 1 when the key is withdrawn in position 1, the switch can still be switched off, but cannot be switched back on again without the key 3 344 20 t0-2-1/e/sva(s) 050977 t0-2-1/i1/sva(s) 207084 ? 1off code letters for lockable switch positions letter s for panic lock with fs908ge 45.57.525 p1-25/e/sva(s) 050966 p1-25/i2/sva(s) 207305 ? 5.5 11 15 32 p1-32/e/sva(s) 044977 p1-32/i2/sva(s) 207326 ? 5.5 11 15 32 t3-2-1/e/sva(s) 050983 t3-2-1/i2/sva(s) 207173 ? on-off switch without emergency-stop function 1) with sva cylinder lock key withdrawable in 0 position only (code letter a) 3 344 20 t0-2-1/e/sva(a) 050976 t0-2-1/i1/sva(a) 207083 t0-2-1/z/sva(a) 050978 45.57.525 p1-25/e/sva(a) 050965 p1-25/i2/sva(a) 207304 p1-25/z/sva(a) 050969 5.5 11 15 32 p1-32/e/sva(a) 050970 p1-32/i2/sva(a) 207325 p1-32/z/sva(a) 050973 5.5 11 15 32 t3-2-1/e/sva(a) 050982 t3-2-1/i2/sva(a) 207172 t3-2-1/z/sva(a) 050984 panic switches with emergency-stop function 2) with sva cylinder lock key withdrawable in positions 0 and 1 when the key is withdrawn in position 1, the switch can still be switched off, but cannot be switched back on again without the key 3 344 20 t0-2-1/e/sva(s)-rt 228971 t0-2-1/i1/sva(s)-rt 207085 ? 45.57.525 p1-25/e/sva(s)-rt 050967 p1-25/i2/sva(s)-rt 207306 ? 5.5 11 15 32 p1-32/e/sva(s)-rt 050971 p1-32/i2/sva(s)-rt 207327 ? 5.5 11 15 32 t3-2-1/e/sva(s)-rt 044972 t3-2-1/i2/sva(s)-rt 207174 ? panic switches with emergency-stop function 2) with svc padlocking feature locking slide can be padlocked in positions 0 and 1. when the locking slide is padlocked in position 1, the switch can still be switched off, but cannot be switched back on again without first removing the padlock. lockable using up to 3 padlocks. 3 344 20 t0-2-1/e/svc(s)-rt 044973 t0-2-1/i1/svc(s)-rt 207086 ? 45.57.525 p1-25/e/svc(s)-rt 044974 p1-25/i2/svc(s)-rt 207307 ? 5.5 11 15 32 p1-32/e/svc(s)-rt 044975 p1-32/i2/svc(s)rt 207328 ? 5.5 11 15 32 t3-2-1/e/svc(s)-rt 044976 t3-2-1/i2/svc(s)-rt 207175 ? on-off switches without emergency-stop function 1) with s-t0 key operation key withdrawable in position 0 only (code letter a) 2 2.2 2.2 ? 20 t0-1-102/ez/s 014933 4) t0-1-102/i1/s 207063 t0-1-102/z/s 014971 notes 1) with black thumb-grip and grey front plate 2) to iec/en 60204-1; with red thumb-grip and yellow front plate 3) enclosure designed for metric cable glands to en 50 262, cable glands a page 07/070 4) degree of protection ip53 1 3 5 2 4 6 fs 908 on off 330 0 30 300 240 225 210 180 150 135 120 90 60 45 270 f h g j k l m n p q r a b c d e 315 1 3 5 2 4 6 fs 908 on off 1 3 5 2 4 6 fs 908 ge 1 0 fs 908 ge 1 0 fs 908 on off 07/050 07/051 moeller hpl0211-2001/2002 t rotary switches switches with locking arrangements rotary switches switch-disconnectors rotary switches switch-disconnectors moeller hpl0211-2001/2002 t rotary switches switches with locking arrangements circuit diagram front plate no. rated uninter- rupted current flush mounting front ip65 surface mounting 1) ip65 rear mounting front ip65 notes i u type article no. price see price list type article no. price see price list type article no. price see price list a std. pack switches with locking arrangements, kms1 lock mechanism hand/auto switches with sva cylinder lock suitable for actuating electronic devices rated uninterrupted current i u 20 a rated operational current i e ac-15 220 ? 240 v 6 a 380 ? 415 v 4 a ac-21a 12 a dc-13 32 v per contact 10 a additional technical data a page 07/090 rotary switches with an sva locking arrangement can also be used as operating mode selector switches for the purposes of eu machine directive 89/392 (minimum switching angle: 60) code letters for lockable switch positions key withdrawable in all positions when the key is withdrawn in the hand position, then start can be actuated without first removing the padlock, but not position 0 (only admissible with separate off switch) 20 t0-2-15907/e/sva(c,e,g-j) 050979 t0-2-15907/i1/sva(c,e,g-j) 207096 ? 1 off 32 t3-2-15907/e/sva(c,e,g-j) 050985 t3-2-15907/i2/sva(c,e,g-j) 207176 ? hand/auto switches with svc padlocking feature locking slide can be padlocked in all positions. when the locking slide is padlocked in the hand position, then start can be actuated without the key, but not position 0 (only admissible with separate off switch) 20 t0-2-15907/e/svc(c,e,g-j) 044996 t0-2-15907/i1/svc(c,e,g-j) 207097 t0-2-15907/z/svc(c,e,g-j) 050980 32 t3-2-15907/e/svc(c,e,g-j) 044997 t3-2-15907/i2/svc(c,e,g-j) 207177 t3-2-15907/z/svc(c,e,g-j) 050986 notes 1) enclosure designed for metric cable glands to en 50 262, cable glands a page 07/070 contactor interlocking circuits control section for standard contactor interlocking circuits. if a standard switch is to contain one of the contactor interlocking circuits as well, it can be ordered using another circuit number from catalogue k115, or as a non- standard switch. the electrical interlocking of rotary switch and contactor makes possible a wide range of control functions. for example: remote disconnection via a stop switch, overload protection via overload relays, protection against automatic restarting after a power failure or overload, and off position interlocking, etc. sond 27 sond 28 sond 29 sond 30 mains disconnection only by contactor. restarting possible only with the rotary switch in the off position. application: primarily for star-delta circuits (only at 60 or 90 switching angles) mains disconnection by contactor and rotary switch together restarting: as sond 27 application: primarily for star-delta and changeover circuits (only at 60 or 90 switching angles) mains connection by contactor, only with the rotary switch in the off position (off position interlock) application: star-delta, changeover and multi-speed circuits mains connection by contactor, only with the rotary switch in a run position each change in the switch position causes the contactor to drop out application: changeover and multi-speed circuits 330 0 30 300 240 225 210 180 150 135 120 90 60 45 270 f h g j k l m n p q r a b c d e 315 0 auto start hand 2 1 3 4 5 6 7 8 fs 1413890 0 auto hand start 0 auto start hand 2 1 3 4 5 6 7 8 fs 1413890 0 auto hand start f0 f2 s0 k1m k1m q1 0 2 1 m 3~ k1m control section sond 27 power section without mains disconnection contact sequence as required f0 f2 s0 k1m k1m q1 01 2 m 3~ km1 control section sond 28 power section with mains disconnection contact sequence as required k1m f0 f2 k1m k1m s1 q1 0 1 2 m 3~ s0 control section sond 29 power section contact sequence as required k1m f0 f2 s0 k1m k1m s1 q1 1 0 2 m 3~ control section sond 30 power section contact sequence as required 07/052 07/053 moeller hpl0211-2001/2002 t rotary switches, p switch-disconnectors front plates rotary switches switch-disconnectors rotary switches switch-disconnectors moeller hpl0211-2001/2002 t rotary switches, p switch-disconnectors front plates standard front plates emergency-stop front plates blank plates non-standard front plates non-standard front plates switch size dimensions yellow can be engraved type article no. price see price list std. pack type article no. price see price list std. pack type article no. price see price list std. pack type article no. price see price list std. pack height of letters mm state the front plate no. required f 2 characters mm > 2 characters mm standard front plates t0, t3, p1 45 x 45 (for frame size 48 x 48) fs...-t0 903197 10 off fs908 ge-t0 003198 5 off fs980-t0 003199 50 off fs-sond-erstbestellung-t0 1) 225355 5 off 4 3 p3, t5, t5b 84 x 84 (for frame size 88 x 88) fs...-p3 995545 10 off fs908 ge-p3 031475 5 off fs980-p3 043340 50 off fs-sond-erstbestellung-p3 2) 225356 5 off 8 5 tm 29 x 29 (for frame size 30 x 30 ) ? ? fs980-tm-e 071438 10 off fs-sond-tm-e 092829 5 off 3.5 2.5 ? ? fs980-tm-ez 073811 50 off fs-sond-tm-ez 095202 5 off 3.5 2.5 1) = first order; for subsequent orders use fs...-t0 2) = first order; for subsequent orders use fs...-p3 standard front plates non-standard front plates the standard front plates illustrated should be used for non-standard switches where possible. standard catalogue front plates for standard switches can be exchanged on request with order, for those illustrated here, at no extra charge (not applicable to t6, t8 and tm), provided the switching angles, the number of switch positions, and the location of the 0 (off) position match. example: t0-1-8210/e+fs161570 inscription to order (note maximum number of characters per field). the fs number is sufficient for reordering. for non-standard t0, t3 and t5(b) switches, the front plate is included in the price. for standard switches, the front plate is included in the price for orders exceeding 49 off. a page 07/113 switching angle 90 switching angle 60 standard front plates arranged in their numerical sequence: switching angle 45 switching angle 30 1 0 heizung- notschalter aus ein stop on off ein start auto zu slow zu off aus stop hand auf ab auf down up fast auto auf aus l3 l2 l1 908 0 1 9508 2 1 902 190719 1 193935 0 1 907 01 945 1992 1 2 943 19334 190550 19143 193975 190431 1922 19589 0 t r s 935 0 9440 2 1 3 4 906 1 0 2 3 912 1+2 1 0 2 193840 9441 0 0 12 1 2 2 1 923 1 2 00 928 192191 1957 1 0 0 1 926 2 1 3 904 2 1 192190 0 1 2 953 0 2 1 910 190334 l3 l2 l1 off on on on off off off on off on off 911 1 3 0 2 start run stop start run slow fast stop slow fast stop auto slow hand fast stop start run netz auf halt not- strom ab auf ab halt halt links rechts auto aus hand auto aus hand auto off hand off l2-n l2-l3 auto off man rev. off forw. stop slow fast rev. stop forw. l1-n l3-n 0 1 611 1 2 601 1601 0 1 2 644 16052 635 y 0 16616 684 0 12 621 0 1 2 161629 0 161570 0 161359 161358 1610 1614 1673 1617 2 1 6034 0 y 606 2 4 1 3 160772 616 1 0 2 3 604 2 1 3 614 0 2 1 164854 164855 655 2 1 3 1665 1662 1628 1627 0 1 164222 2 1 3 4 0 667 645 2 1 3 4 0 629 1 0 1 2 2 161002 638 y 0 y 161683 1 0 2 3 4 618 620 1 0 2 3 4 5 610 2 1 3 4 5 6 640 2 1 0 0 2 1 y 0 0 y 6010 164721 661 l1-l2 l3-l1 high off med. low s-t t-r r-o r-s t-o s-o l2-l3 l3-l1 l1-l2 l3-n l1-n l2-n start 301 1 2 3 4 5 6 7 8 9 10 11 12 310 1 2 3 4 5 6 7 8 9 10 11 0 302 1 2 3 4 5 6 7 8 9 10 11 311 1 2 3 4 5 6 7 8 9 10 0 303 1 2 3 4 5 6 7 8 9 10 312 4 2 0 3 9 6 8 15 7 304 1 2 3 4 5 6 7 8 9 313 1 2 3 4 5 6 7 8 0 305 1 2 3 4 5 6 7 8 314 1 2 3 4 5 6 7 0 315 1 2 3 4 5 6 0 307 1 2 3 4 5 6 316 1 2 3 4 5 0 308 1 2 3 4 5 317 1 2 3 4 0 309 1 2 3 4 408 3 2 4 5 1 414 2 1 3 4 5 6 8 7 428 0 2 1 3 4 5 6 7 412 3 2 1 7 6 5 4 426 2 1 0 3 4 6 5 410 3 2 4 5 1 6 424 2 1 0 3 4 5 422 2 1 0 3 4 406 2 3 1 4 420 2 1 0 3 404 3 2 1 418 2 1 0 429 0 2 1 0 1 415 1 2 402 416 0 1 610 2 1 3 4 5 6 614 0 2 1 604 2 1 3 616 1 0 2 3 606 2 4 1 3 1 2 601 0 1 611 496 1 2 453 2 3 1 4 0 449 0 2 1 1 2 3 3 459 2 1 0 2 1 456 0 1 458 0 1 2 462 2 1 0 461 0 1 2 455 1 0 2 1 3 904 2 1 3 4 906 0 1 907 2 1 902 640 2 1 0 0 2 1 620 1 0 2 3 4 5 638 y 0 y 635 y 0 621 0 1 2 629 1 0 1 2 2 0 1 2 644 645 2 1 3 4 0 655 2 1 3 661 2 1 3 4 0 667 684 0 12 1420 1411 0 2 1 1409 1404 1403 1401 0 980 0 1 2 953 01 945 1 2 943 0 t r s 935 1 2 00 928 1 0 0 1 926 1 2 2 1 923 0 2 1 910 1423 1 1426 0 1446 0 1475 1601 1610 1614 1617 2 1 1627 1628 1662 1665 1673 1922 1957 1992 4011 0 12 4017 y 0 y 4026 2 0 1 4117 2 0 1 4721 1 4722 1 0 4723 0 y 0 0 y 6010 6034 0 y 0 9440 9441 0 0 12 0 1 9508 14195 0 14196 0 14510 1 14712 14944 0 147474 0 147472 142074 0 2 1 142003 141883 141879 141538 141537 140660 0 12 140055 0 41409 1 2 0 19589 19334 19143 16616 16052 14988 0 147479 147767 1 0 160772 161002 161358 161359 161570 0 161629 0 161683 0 1 164222 164721 164854 164855 190334 190431 190550 190719 0 1414000 1413905 1413903 0 1413890 0 1410763 1410759 0 1410758 0 1410757 0 1410756 0 1410755 0 194323 194321 193975 1 193935 1+2 1 0 2 193840 192191 2 1 192190 s-t t-r r-s s-o t-o r-o s-t t-r r-s s-o r-o r-s s-o t-o hand auto s-t t-r t-o r-o zu- ruck halt vor. links rechts halt start start auto aus hand hand auto off ein aus off on auto hand aus auto off on off zu auf start start stop forw. rev. trip close auto hand hand hand auto auto aus aus auto off off off off man man rev. forw. stop slow fast auto hand ein aus ein aus links rechts lang- sam aus schnell ein aus stop start stop start start forw. rev. off on stop start stop start hand auto heizung- notschalter stop forw. rev. start start start l3 l1 l2 l3 l1 l2 off ab auf stop start run stop slow fast zu auf zu auf s-t t-r r-s r-s s-t t-r stop start slow fast l2-n l3-n l1-n l2-l3 l3-l1 l1-l2 down off up l2-l3 l3-l1 l1-l2 l2-n l3-n l1-n l2-l3 l3-l1 l1-l2 l2-n l3-n l1-n l2-l3 l3-l1 l1-l2 l2-n l3-n l1-n l2-l3 l3-l1 l1-l2 l1-l2 l2-n l3-n l1-n l2-l3 l3-l1 l1-l2 l2-n l3-n l1-n l2-l3 l3-l1 l1-l2 l1-n off l2-l3 l3-l1 l1-l2 off off on low start off off off on l2-n l3-n l1-n l2-l3 l3-l1 l1-l2 off med. high stop slow slow fast fast stop links rechts halt ab auf halt ab auf netz not- strom start start run run stop hand auto hand auto hand off raise start lower auto 142010 1 0 start 911 1 3 0 2 318 1 2 3 0 441 1 0 1 2 2 1 0 2 3 4 618 908 on off 912 2 0 1 3 off on stop start auto hand start stop auto hand hand auto auto off auto aus hand 416 0 1 1 2 402 0 1 415 142003 147472 141883 455 1 0 142010 1 0 141879 4721 1 4722 1 0 4723 0 496 1 2 41409 1 2 0 429 0 2 1 1401 0 1413905 0 1414000 4117 2 0 1 462 2 1 0 4026 2 0 1 461 0 1 2 147767 1 0 141538 1403 1404 1475 1420 1411 4011 0 12 458 0 1 2 1426 0 14988 0 147474 0 1413903 0 1446 0 456 0 1 1423 1 14510 1 141537 1413890 0 418 2 1 0 404 3 2 1 420 2 1 0 3 406 2 3 1 4 422 2 1 0 3 4 408 3 2 4 5 1 441 1 0 1 2 2 453 2 3 1 4 0 4017 y 0 y 459 2 1 0 2 1 1409 0 2 1 140660 0 12 14712 142074 0 2 1 424 2 1 0 3 4 5 410 3 2 4 5 1 6 426 2 1 0 3 4 6 5 412 3 2 1 7 6 5 4 449 0 2 1 1 2 3 3 428 0 2 1 3 4 5 6 7 414 2 1 3 4 5 6 8 7 1410757 0 14196 0 1410755 0 14195 0 1410756 0 1410758 0 1410759 0 147479 14944 0 1410763 140055 0 194321 194323 hand auto off lang- sam aus schnell zu- ruck links rechts halt halt vor. stop start forw. rev. hand trip ein close aus zu auf raise lower links rechts ein aus start stop stop forw. rev. start start auto hand start start start rev. stop start forw. start start start start l2-n l3-n l1-n s-o t-o r-o l2-l3 l3-l1 l1-l2 l2-n l3-n l1-n l2-l3 l3-l1 l1-l2 s-t t-r r-s l2-l3 l3-l1 l1-l2 l2-n l3-n l1-n l1-n l1-l2 l2-n l3-n l1-n l2-l3 l3-l1 l1-l2 off off l2-l3 l3-l1 l1-l2 l2-n l3-n l1-n off off l2-l3 l3-l1 l1-l2 l2-l3 l3-l1 l1-l2 s-t t-r r-s s-o t-o r-o s-t t-r r-s r-s s-t t-r 318 1 2 3 0 309 1 2 3 4 317 1 2 3 4 0 308 1 2 3 4 5 316 1 2 3 4 5 0 307 1 2 3 4 5 6 315 1 2 3 4 5 6 0 314 1 2 3 4 5 6 7 0 305 1 2 3 4 5 6 7 8 313 1 2 3 4 5 6 7 8 0 304 1 2 3 4 5 6 7 8 9 312 4 2 0 3 9 6 8 15 7 303 1 2 3 4 5 6 7 8 9 10 311 1 2 3 4 5 6 7 8 9 10 0 302 1 2 3 4 5 6 7 8 9 10 11 310 1 2 3 4 5 6 7 8 9 10 11 0 301 1 2 3 4 5 6 7 8 9 10 11 12 07/054 07/055 moeller hpl0211-2001/2002 t rotary switches, p switch-disconnectors accessories rotary switches switch-disconnectors rotary switches switch-disconnectors moeller hpl0211-2001/2002 t rotary switches, p switch-disconnectors accessories for use with type suffix price std. pack type price std. pack type suffix price std. pack type price article no. see price list article no. see price list article no. see price list article no. see price list std. pack when ordered with basic unit when ordered separately when ordered with basic unit when ordered separately add-on front plates, clip-on for use with front plates and for padlocking features. they comprise a black label mount and an insert plate. blank, can be engraved t.../i2/svb(-sw) and p.../i2/svb(-sw) except...i1, 2.../ivs t..., p..., except.../i1, 2, 3 .../ivs ? zfs60-t0 019924 25 off ? zfs60-p3 022297 25 off zfs...-t0 and zfs...-p3 can be used for any t... and p... switches, as required. dimensions with frame w x h = 48 x 17 mm dimensions with frame w x h = 88 x 27 mm with inscription: ?main switch - open only in the off position? t.../e, t.../z, p.../e, p.../z 61/62 = german/english 63 = french 64 = bulgarian 65 = danish 66 = finnish 67 = dutch 68 = italian 69 = greek 70 = norwegian 71 = polish 72 = portuguese 73 = romanian 74 = russian 75 = swedish 76 = serbo-croat 77 = spanish 78 = czech 79 = turkish 80 = hungarian 81 = afrikaans +zfs61/62-t0 065740 1off zfs61/62-t0 030170 25 off +zfs61/62-p3 065742 1off zfs61/62-p3 065739 25 off zfs61/62-... included as standard with t.../ea/svb, p.../ea/svb t.../v/svb, p.../v/svb +zfs63-t0 065741 zfs63-t0 047424 +zfs63-p3 065743 zfs63-p3 047423 +zfs64-t0 205501 zfs64-t0 205535 +zfs64-p3 205518 zfs64-p3 205552 +zfs65-t0 205502 zfs65-t0 205536 +zfs65p3 205519 zfs65p3 205553 +zfs66-t0 205503 zfs66-t0 205537 +zfs66-p3 205520 zfs66-p3 205554 +zfs67-t0 065744 zfs67-t0 065750 +zfs67-p3 065747 zfs67-p3 065753 +zfs68-t0 065745 zfs68-t0 065751 +zfs68-p3 065748 zfs68-p3 065754 +zfs69-t0 205504 zfs69-t0 205538 +zfs69-p3 205521 zfs69-p3 205555 +zfs70-t0 205505 zfs70-t0 205539 +zfs70-p3 205522 zfs70-p3 205556 +zfs71-t0 205506 zfs71-t0 205540 +zfs71-p3 205523 zfs71-p3 205557 +zfs72-t0 205507 zfs72-t0 205541 +zfs72-p3 205524 zfs72-p3 205558 +zfs73-t0 205508 zfs73-t0 205542 +zfs73-p3 205525 zfs73-p3 205559 +zfs74-t0 205509 zfs74-t0 205543 +zfs74-p3 205526 zfs74-p3 205560 +zfs75-t0 205510 zfs75-t0 205544 +zfs75-p3 205527 zfs75-p3 205561 +zfs76-t0 205511 zfs76-t0 205545 +zfs76-p3 205528 zfs76-p3 205562 +zfs77-t0 065746 zfs77-t0 065752 +zfs77-p3 065749 zfs77-p3 047422 +zfs78t0 205512 zfs78t0 205546 +zfs78-p3 205529 zfs78-p3 205563 +zfs79-t0 205513 zfs79-t0 205547 +zfs79-p3 205530 zfs79-p3 205564 +zfs80-t0 205514 zfs80-t0 205548 +zfs80-p3 205531 zfs80-p3 205565 +zfs81-t0 205515 zfs81-t0 205549 +zfs81-p3 205532 zfs81-p3 205566 label mounts, black t.../i2/svb(-sw) and p.../i2/svb(-sw) except...i1, 2.../ivs t..., p..., except.../i1, 2, 3 .../ivs ? zfsx-t0 024670 25 off ? zfsx-p3 027043 25 off zfsx...-t0 and zfsx...-p3 can be used for any t... and p... switches, as required. zfsx...-t0: dimensions with frame w x h = 48 x 17 mm zfsx...-p3: dimensions with frame w x h = 88 x 27 mm 07/056 07/057 moeller hpl0211-2001/2002 t rotary switches, p switch-disconnectors accessories rotary switches switch-disconnectors rotary switches switch-disconnectors moeller hpl0211-2001/2002 t rotary switches, p switch-disconnectors accessories for use with key withdrawal type suffix price key withdrawal type price article no. see price list article no. see price list std. pack notes when ordered with basic unit when ordered separately s-t0 key operated lock mechanism, front ip53 includes two keys kms 1 lock mechanism individual lock mechanism, not suitable for master key systems t0-.../e, .../i1, .../z up to 6 contact units t3-.../e, .../i2, .../z up to 5 contact units p1-.../e, .../i2, .../z key withdrawal positions are programmed ex- works to match the switch +s-t0 001753 key withdrawal positions can be programmed by the user s-t0 086709 1 off s-t0 can be used for p1-..., t0-1... to t0-6... and t3-1... to t3-5... switches. the key replaces the thumb-grip. switching is not possible with- out the key. the switch position indicator is on the lock. in standard applications, the key can be withdrawn in any position, on switches with fs908, only in the off position. new positions for key withdrawal can be selected (even retrospectively) by fitting vr-t0 locking cams. the switching angle is determined by the switch. when retrofitting the s-t0, use the front plate of the switch. lock mechanism: standard kms 1 (ces lock) sva-t3 can be fitted to t0, t3 and p1 switches. switching is carried out using the thumb-grip. the switch is locked by turning the key; the key is withdrawable. in standard applications, all positions are lockable. lock mechanism: standard kms 1 (ces lock). individual positions or ranges can be locked (also with vr-t3 fitted by the user). the key cannot be withdrawn in positions which are not lockable. where ranges are locked, switching without the key is possible only within a locked range. the lockable positions or ranges are shown below; use the code letters to state your selection on the order: example 1: sva(a)-t3 = only position a lockable example 2: sva(a, e)-t3 = positions a and e lockable example 3: sva(a?j)-t3 = range a to j lockable example 4: sva(s)-t3 = main switches, for use as emergency- stop devices to iec/en 60 204-1; with red handle and yellow front plate as panic lock version, lockable in positions a and e; switching is still possible from e to a, but not from a to e. when retrofitting the sva-t3, use the front plate of the switch. with letter s for panic lock, use fs908ge. ordering example: p1-25/i2-rt+sva(s)-t3 . letter s for panic lock with fs908ge ordering example: sva(a-g)-sond-(saa 6294-1/2) kms 2?10 1) lock mechanisms kms 201?400 1) lock mechanisms individual lock mechanisms, not suitable for master key systems +s-sond(kms...)-t0 903210 s-sond(kms...)-t0 903207 there is no master key for kms...- lock mechanisms (sae) = individual lock mechanism supplied with a security certificate +s-sond(sae)-t0 003212 s-sond(sae)-t0 003209 (sa...) = master key system (with master key) supplied with a security certificate. see also note below. 2) +s-sond-(sa...)-t0 914737 s-sond-(sa...)-t0 991023 sva-t3 cylinder lock, front ip65 includes two keys key withdrawable in all positions kms 1 lock mechanism individual lock mechanism, not suitable for master key systems t0-.../e, .../i1, .../z t3-.../e, .../i2, .../z p1-.../e, .../i2, .../z key withdrawal positions are programmed ex- works to match the switch +sva-t3 050962 key withdrawal positions can be programmed by the user sva-t3 050974 1 off kms 2?10 1) lock mechanisms kms 201?400 1) lock mechanisms individual lock mechanisms, not suitable for master key systems +sva-sond-kms...-t3 907739 sva-sond-kms...-t3 907747 key can be withdrawn in positions as specified kms 1 lock mechanism switches with fs 908 are suitable as main switches: t0-1-... to t0-4-.../i1, .../e t3-1-... to t3-5-.../i2 t3-1-... to t3-6- .../e p1-.../i2, .../e t0-.../e, .../i1, .../z t3-.../e, .../i2, .../z p1-.../e, .../i2, .../z key withdrawal positions are programmed ex- works as ordered +sva(...)-t3 907737 key withdrawal positions are programmed ex-works as ordered sva(...)-t3 907745 kms 2?10 1) lock mechanisms kms 201?400 1) lock mechanisms individual lock mechanisms, not suitable for master key systems +sva(...)-sond-kms...-t3 907734 sva(...)-sond-kms...-t3 907742 (sae) = individual lock mechanism supplied with a security certificate +sva(...)-sond-sae-t3 907736 sva(...)-sond-sae-t3 907744 (sa...) = master key system (with master key) supplied with a security certificate. order must include a lock plan (fo276) showing the full configuration of the envisaged lock system. for subsequent part orders, simply state the item number within the lock plan, e.g. (x4711, item 7). 2) +sva(...)-sond-(sa...)-t3 914735 sva(...)-sond-(sa...)-t3 914736 notes 1) kms 1: can be supplied ex-stock; kms 2 ? 10, 201 ? 400 and master key systems: delivery time < 6 weeks from order receipt at the factory 2) for subsequent orders, the keys must be ordered separately a page 07/061 330 0 30 300 240 225 210 180 150 135 120 90 60 45 270 f h g j k l m n p q r a b c d e 315 07/058 07/059 moeller hpl0211-2001/2002 t rotary switches, p switch-disconnectors accessories rotary switches switch-disconnectors rotary switches switch-disconnectors moeller hpl0211-2001/2002 t rotary switches, p switch-disconnectors accessories for use with locking facility type suffix price locking facility type price article no. see price list article no. see price list std. pack notes when ordered with basic unit when ordered separately svc-t3 padlocking feature, front ip65 in the depressed position, the locking slide is lockable with up to 3 padlocks all positions are lockable t0-.../e, .../i1, .../z t3-.../e, .../i2, .../z p1-.../e, .../i2, .../z lockable positions are programmed ex-works to match the switch +svc-t3 050963 lockable positions can be programmed by the user svc-t3 050975 1 off svc-t3 can be fitted to t0, t3 and p1 switches. switching is carried out using the thumb-grip, and interlocking by depressing an actuator which can be locked in position using up to 3 padlocks. in standard applications, all positions are lockable. with type reference svc(...)-t3, only the specified positions or ranges are lockable. where ranges are locked, switching is possible only within a locked range, unless the padlock is removed first. the lockable positions or ranges for svc(...)-t3 and the locked position for dtv(...)-t3 are shown below. as with sva(...)-t3, use the code letters to state your selection on the order: example 1: svc(a)-t3 = only position a lockable example 2: svc(a, e)-t3 = positions a and e lockable example 3: svc(a?j)-t3 = range a to j lockable example 4: dtv(g)-t3 = the release mechanism must be actuated to allow switching in this position. example 5: svc(s)-t3 = main switches, for use as emergency- stop devices to iec / en 60 204-1; with red handle and yellow front plate as panic lock version, lockable in positions a and e; switching is still possible from e to a, but not from a to e. when retrofitting the sva-t3, use the front plate of the switch. with letter s for panic lock, use fs908ge. ordering example: p1-25/i2-rt+svc(s)-t3 master keys must always be ordered separately. please send or submit the security certificate with repeat orders. for sa(...), the precise designation of the key must be stated e.g. svs-sa(a6294-1/2) specified positions or ranges are lockable switches with fs908 may be used as main switches for t0-1-... to t0-4-.../i1, .../e t3-1-... to t3-5-.../i2 t3-1-... to t3-6-.../e p1-.../i2, .../e lockable positions are programmed ex- works as ordered +svc(...)-t3 907740 lockable positions are programmed ex- works as ordered svc(...)-t3 907748 1 off dtv-t3 push-button interlock, front ip65 only after depressing the release button is it possible to switch from an unlocked position or range into a locked position or range, but not the reverse (protection against tampering). with a padlock in place when the release button is in the non-actuated position, it is not possible to switch into the locked positions. t0-.../e, .../i1, .../z t3-.../e, .../i2, .../z p1-.../e, .../i2, .../z lockable using 2 padlocks lockable positions are programmed ex-works to match the switch +dtv-t3 050961 ? 1 off specified positions locked release mechanism can be locked in the non-actuated position with 1?2 padlocks lockable positions are programmed ex- works as ordered +dtv(...)-t3 907733 ? 1 off locking cams (2 cams per set) for user to select indexing position in which key can be withdrawn s-t0 for all switching angles ? vr-t0 089082 1 off for changing the locked positions/ranges sva-t3, svc-t3, for all switching angles for dtv-t3: order 2 x vr-t3 ? vr-t3 050987 1 off keys for kms 1 individual lock mechanism s-t0, sva-t3 ? svs-kms1 001871 1 off for kms 2 ? 10 individual lock mechanism or kms 201 ? 400 s-t0, sva-t3 ? svs-km... 914714 for master key systems and recorded individual lock mechanisms: state lock plan no. and lock s-t0, sva-t3 ? svs-sa(...) 901982 330 0 30 300 240 225 210 180 150 135 120 90 60 45 270 f h g j k l m n p q r a b c d e 315 07/060 07/061 moeller hpl0211-2001/2002 t rotary switches, p switch-disconnectors accessories rotary switches switch-disconnectors rotary switches switch-disconnectors moeller hpl0211-2001/2002 t rotary switches, p switch-disconnectors accessories for use with type suffix price type price article no. see price list article no. see price list std. pack when ordered with basic unit when ordered separately main switch assembly kits padlocking feature, exclusively for main switches, to permit them to be used as emergency-stop devices 1) admissible for t0 up to 4 contact units and for t3... up to 6 contact units t0-.../e, .../z, .../i1 t3-.../e, .../z, .../i2 p1-.../e, .../z, .../i2 +svb-t0 026450 svb-t0 057892 1 off for locking in the 0 (off) position: for switches with the positions 0 ? i at 90 switching angle, as front plate: fs908 t5(b)-.../e, .../z, .../i4 p3-63/e, .../z, .../i4 p3-100/e, .../z, .../i5 +svb-p3 026364 svb-p3 052999 1 off padlocking feature, exclusively for main switches without emergency-stop function black handle, black locking collar admissible for t0 up to 4 contact units and for t3... up to 6 contact units t0-.../e, .../z, .../i1 t3-.../e, .../z, .../i2 p1-.../e, .../z, .../i2 +svb-sw-t0 076917 svb-sw-t0 060265 1 off for locking in the off position or in the on position if required. lockable using up to 3 padlocks padlocks with kms lock mechanism, type 219/38 (kms...): please enquire. t5(b)-.../e, .../z, .../i4 p3-63/e, .../z, .../i4 p3-100/e, .../z, .../i5 ? svb-sw-p3 062491 1 off main switch assembly kits, with pe terminal and n terminal padlocking feature, exclusively for main switches, to permit them to be used as emergency-stop devices 1) admissible for t0 up to 4 contact units and for t3... up to 6 contact units t0-.../e, .../z t3-.../e, .../z ? v/ea/svb-t0 062638 1 off for conversion of: t.../e flush mounting switches (with front plate fs908) into t.../ea/svb... flush mounting main switches t.../z rear mounting switches (with front plate fs908) into t.../v/svb interlocked rear mounting main switches t5(b)-.../e, .../z ? v/ea/svb-t5 045065 padlocking feature, exclusively for main switches without emergency-stop function black handle, black locking collar admissible for t0 up to 4 contact units and for t3... up to 6 contact units t0-.../e, .../z t3-.../e, .../z ? v/ea/svb-sw-t0 065011 t5(b)-.../e, .../z ? v/ea/svb-sw-t5 045064 thumb-grips black t0-.../e, .../ez, .../ivs, .../z, .../i1 t3-.../e, .../ez, .../ivs, .../z, .../i2 p1-.../e, .../ez, .../ivs, .../z, .../i2 ? knb-t0 038909 1 off red t0-.../e, .../ivs, .../z, .../i1 t3-.../e, .../ivs, .../z, .../i2 p1-.../e, .../ivs, .../z, .../i2 +knb-rt-t0 003214 knb-rt-t0 043655 when ordered separately: use red handle to iec/en 60 204 for emergency-stop switches only, and order corresponding yellow front plate fs908ge-t0 black t5(b)-.../e, .../z, .../i4 p3-63/e, .../z, .../i4 p3-100/e, .../z, .../i5 ? knb-p3 041282 1 off red t5(b)-.../e, .../z, .../i4 p3-63/e, .../z, .../i4 p3-100/e, .../z, .../i5 +knb-rt-p3 003215 knb-rt-p3 046028 when ordered separately: use red handle to iec/en 60 204 for emergency-stop switches only, and order corresponding yellow front plate fs908ge-p3 maintenance keys for interlocked main switches t0-.../v, t3-.../v, p1-.../v ? knk-t0 000650 1 off special devices for electricians, to allow them to switch interlocked main switches on and off, when the panel door is open for maintenance purposes (to iec/en 60 204 part 1, clause 5.1.1.1) t5(b)-.../v, p3-.../v ? knk-p3 000649 1 off notes 1) to iec/en 60 204-1; with red rotary handle and yellow locking collar, lockable in 0 (off) position 07/062 07/063 moeller hpl0211-2001/2002 t rotary switches, p switch-disconnectors accessories rotary switches switch-disconnectors rotary switches switch-disconnectors moeller hpl0211-2001/2002 t rotary switches, p switch-disconnectors accessories for use with type suffix price type price article no. see price list std. pack article no. see price list std. pack when ordered with basic unit when ordered separately neutral poles early-make, late-break can be fitted to left and/or right of 3-pole p switch-disconnectors p1-.../e, .../ea, .../ez ? n-p1e 000651 5 off the neutral contact is always early-make and late-break. switching capacity of n-p1... equivalent to p1-32... contacts with p1-.../i2: optional n-p1z or hi11-p1/p3z can only be fitted to left p1-.../z, .../v, .../i2, .../st, .../ivs +n-p1z 000416 1 off n-p1z 000652 p3-.../e, .../ea... ? n-p3e 062432 the neutral contact is always early-make and late-break. switching capacity of n-p3... equivalent to p3-100... contacts p3-.../z, .../v, .../ivs p3-63/e, .../z, .../i4, .../st p3-100/e, .../z, .../i5, .../st +n-p3z 009036 1 off n-p3z 064805 auxiliary contacts 1 make contact, 1 break contact can be fitted to left and/or right of 3-pole p switch-disconnectors p1-.../e, .../ea..., .../ez p3-.../e, .../ea +hi11-p1/p3e 064100 1 off hi11-p1/p3e 061813 5 off the make contact is always connected as a load-shedding contact, i.e. late-make, early-break. with p1-.../i2: hi11-p1/p3z or n-p1z can be fitted to left only p1-.../z, .../v, .../i2, .../st, .../ivs p3-63/z, .../v, .../i4, .../st, .../ivs p3-100/z, .../v, .../i5, .../st, .../ivs +hi11-p1/p3z 064526 1 off hi11-p1/p3z 062031 5 off centre mounting accessories for single-hole fitting mounting diameter 22.3 mm with front plate t0-.../e, t3-.../e +ez-t0 001750 1 off ez-t0 081622 1 off rapid snap-fitting in panel sides, plates and doors. legend plates from the rmq range of control circuit devices can be used. without front plate for engraved front plates t0-.../e, t3-.../e +ez/ofs-t0 001751 1 off ez/ofs-t0 001869 1 off mounting diameter 22.3 mm and 30.5 mm t0-.../e, t3-.../e, p1-.../e +ez-p1 026222 1 off ez-p1 091455 5 off screw fixing enables one person to fit the equipment into panel sides, plates and doors. legend plates from the rmq range of control circuit devices can be used. service distribution board mounting accessories includes push-fit shaft t0-.../xz +ivs-t0 045472 1 off ivs-t0 091114 1 off use the front plate of the basic switch for retrofitting t0-.../xz basic switches as t0-.../ivs into service distribution boards 07/064 07/065 moeller hpl0211-2001/2002 t rotary switches, p switch-disconnectors accessories rotary switches switch-disconnectors rotary switches switch-disconnectors moeller hpl0211-2001/2002 t rotary switches, p switch-disconnectors accessories for use with type suffix price type price article no. see price list std. pack article no. see price list std. pack when ordered with basic unit when ordered separately coupling drive includes push-fit shaft for retrofitting t0(t3)-.../xz basic switches in the rear mounting form spare parts for t0(t3)/(p1)-.../z ? de-t0 093487 1 off for conversion of t5 (b)-.../e flush mounting switch into a rear mounting switch spare parts for t5(b)/(p3)-.../z ? de-p3 093972 3 off interlock sections with pe and n conductor connection t0-.../e, .../ez t3-.../e, .../ez p1-.../e, .../ez +uv-t0 038519 1 off uv-t0 019925 1 off fits on the reverse of flush mounting switches t5(b)-.../e p3-.../e +uv-p3 030402 1 off uv-p3 048289 1 off for cover or door interlock with pe and n conductor connection t0-.../z t3-.../z p1-.../z +uv-t0 038519 1 off uv-t0 019925 1 off with interlocking function for rear mounting switches t5(b)-.../z p3-.../z +uv-p3 030402 1 off uv-p3 048289 1 off interlock extensions 1) up to four off, 25 mm each, can be plugged onto interlock section (an equal number of shaft extensions is required for this purpose) uv-t0 +zvv-t0 024662 1 off zvv-t0 022298 10 off notes relating to installation in enclosures a page 07/089 uv-p3 +zvv-p3 024379 1 off zvv-p3 024671 10 off shaft extensions up to four off, 25 mm each, can be plugged onto switch shaft t0-.../z t3-.../z p1-.../z +zav-t0 023736 1 off zav-t0 027044 10 off notes relating to installation in enclosures a page 07/089 t5(b)-.../z p3-.../z +zav-p3 026623 1 off zav-p3 029417 10 off notes 1) use zvv-t0 only with t0/t3-.../z and p1-.../z use zvv-p3 only with t5(b)-.../z and p3-.../z 07/066 07/067 moeller hpl0211-2001/2002 t rotary switches, p switch-disconnectors accessories rotary switches switch-disconnectors rotary switches switch-disconnectors moeller hpl0211-2001/2002 t rotary switches, p switch-disconnectors accessories for use with type suffix price type price article no. see price list article no. see price list std. pack when ordered with basic unit when ordered separately sleeves/covers for flush-mounting switches with up to 4 contact units t0-.../e t3-.../e p1-.../e ? h3-t0 093828 1 off cable entries quantity: 2 x o 20 mm + 2 x o 15 mm cross-section: 5 x 6 mm 2 5 x 2.5 mm 2 cover for protection of terminals for up to 2 contact units t5(b)-.../e, .../z ? h1-t5 045062 1 off can be used for input and/or output wiring extension of h1-t5 cover to protect 3 to 8 contact units h1-t5 ? hz-t5 045063 10 off 1 x hz-t5 required per contact unit to cover terminals on 3-pole switch-disconnectors p1-.../e, .../ez, .../z, .../ea, .../v ? h-p1 017253 5 off can be used for input and/or output wiring p1-...n, ...hi11, ...n...hi11 ? h-p14 019626 5 off to cover terminals on 3-pole open switch-disconnectors with n neutral conductor and/or hi11 auxiliary contact modules fitted p3-.../e, .../z, .../ea, .../v p3-...n, ...hi11, ...n...hi11 ? h-p3 021999 5 off the shroud is designed for fitting onto both sides of the switch-disconnector. parts which are not required can be broken off. cover assembly to protect the 6 terminals t6-160-6/... ? h-t6-160 200183 1 off cover assembly to protect the 6 terminals t8-3-8342/... ? h-t8 200184 1 off 07/068 07/069 moeller hpl0211-2001/2002 t rotary switches, p switch-disconnectors accessories rotary switches switch-disconnectors 07/070 for use with type price article no. see price list std. pack insulated enclosures, ip65 enclosures designed for metric cable glands to en 50 262 1 ? 2 contact units t0-.../xz ci-k1-t0-2 207435 1 off cable sizes which may be pushed through the diaphragm 3 ? 4 contact units t0-.../xz ci-k1-t0-4 207436 type main-/control current 1 ? 2 contact units t3-.../xz ci-k2-t3-2 207437 cl-k1-t0-... cl-k2-t3-... 12 mm 16 mm ? 8mm 3 ? 4 contact units t3-.../xz ci-k2-t3-4 225325 5 contact units t3-.../z ci-k2-t3-5 207438 1 ? 2 contact units t5b-.../e ci-k4-t5b-2 207439 3 ? 4 contact units t5b-.../z ci-k4-t5b-4 207440 1 ? 2 contact units t5-.../z ci-k5-t5-2 207441 converts t5-.../z into t5-.../i5 and t5b-.../e into t5b.../i4: order aw-t5-... extension terminals in addition a page 07/071 3 ? 4 contact units t5-.../z ci-k5-t5-4 207442 neutral terminals for connection of 5th conductor t0-.../i1, cl-k1-t0-... t3-.../i2, cl-k2-t3-... p1-.../i2 k-ci-k1/2 207451 20 off t5b-.../i4, cl-k4-t5b-... p3-.../i4 k-ci-k4 206916 20 off t5-.../i5, cl-k5-t5-... p3-.../i5 k-ci-k5 218488 1 off set of external fixing brackets t5b-.../i4, t5-.../i5, p3-63/i4, p3-100/i5, ab-ci-k4/5 206914 1 off for fixing ci-k4 and ci-k5 directly to the wall one set comprises 4 brackets metric diaphragm grommets ip65 with integral push-through diaphragm external cable diameter mm cable entry hole diameter mm h03vv-f 3 x 0.75 mm2, nym 5 x 1.5/5 x 2.5 mm2 kt-m20 207602 100 off 1 ? 13 m20 20.5 h03vv-f 3 x 0.75 mm2, nym 4 x 10 mm2 kt-m25 207603 1 ? 18 m25 25.5 h03vv-f 3 x 0.75 mm2, nym 4 x 16/5 x 10 mm2 kt-m32 207604 1 ? 24 m32 32.5 metric cable glands to en 50 262 with lock nut and integral cable clamp ip68 up to 5 bar, halogen free h05vv-f 4 x 2.5/3 x 4 mm2, nym 5 x 1.5/5 x 2,5 mm2 v-m20 206910 20 off 6 ? 13 m20 20.5 h05vv-f 5 x 2.5/5 x 4 mm2, nym 5 x 2.5/5 x 6 mm2 v-m25 206911 20 off 9 ? 17 m25 25.5 nym 5 x 10 mm2 v-m32 206912 10 off 13 ? 21 m32 32.5 nym 5 x 16 mm2 v-m32g 226156 10 off 18 ? 25 m32 32.5 nym 4 x 35/5 x 25 mm2 v-m50 206913 5 off 18 ? 35 m50 50.5 rotary switches switch-disconnectors 07/071 moeller hpl0211-2001/2002 t rotary switches, p switch-disconnectors accessories for use with type price article no. see price list std. pack set of extension terminals for cable connection in the enclosure for the lowest contact unit t5b-.../i4 t5-.../i5 aw-t5-1/2 032601 1 off included with t5b-.../i4 and t5-.../i5 as standard fit t5(b) with extension terminals to install it as t5(b)-.../e in an insulated enclosure. for the second contact unit from the bottom t5-.../i5 aw-t5-3/4 032602 1 off indicator lights, conical, ba9s for fitting in m20/m25 pre-mouldings in the enclosure base for filament bulbs and neon bulbs up to 2.4 w a page 02/040 colour: red p1-.../i2, p3-.../i..., t...-.../i... l-r 208689 5 off colour: white l-w 208692 colour: green l-g 208690 colour: yellow l-y 208691 set of adapter rings to allow pg cable glands to be used in metric cable entries m25-pg16 218923 1 set 1 set = 50 off m32-pg21 218924 1 set = 25 off m40-pg29 218925 1 set = 10 off m50-pg36 218926 1 set = 10 off moeller hpl0211-2001/2002 tm mini rotary switches system overview rotary switches switch-disconnectors 07/072 tm on-off switches tm control switches 1 2 5 3 4 4 4 6 6 6 7 8 8 8 8 9 8 9 10 8 auto hand o 2 11 3 4 5 6 6 6 4 4 9 9 10 1 rotary switches switch-disconnectors 07/073 moeller hpl0211-2001/2002 tm mini rotary switches system overview flush mounting (.../e) 1 front ip65 fitting from rear in panel sides, plates or doors terminal: pozidriv screw finger-proof a page 07/074 flush mounting control circuit isolators (.../e/svb) 1 front ip65 to iec/en 60 947-5 lockable in 0 (off) position using two padlocks, 4 mm ? or 1 padlock, 6 mm ? can be used at up to 250 v ac per contact up to 6 contacts admissible a page 07/074 product attributes contact chamber ? rated uninterrupted current 10 a gold-plated contacts for safe switching of extra low voltages and currents even in corrosive atmospheres positively opening contacts 1 ? 2 contacts per contact chamber, up to 16 contacts per switch switching of differing potentials control circuit reliability centre mounting (.../ez) 2 front ip65 mounting in a standard 16.2 mm aperture, or in 22.3 mm to iec/en 60 947-5-1 following removal of supplied adapter m22-st... legend plate mounts from the rmq control circuit range can be used for marking (see page 02/027) a page 07/074 key operation for centre mounting 3, 4 2 keys are supplied option for key withdrawal at 90 with kaba micro cylinder lock option for key withdrawal at 60 with ronis cylinder lock always state the position in which the key is to be withdrawable a page 07/083 circuit diagrams (examples) switch position 1: contact 1 ? 2 open, contact 3 ? 4 closed. switching from 1 to 2: contact 1 ? 2 early-make, contact 3 ? 4 late-break. switching from 2 to 3: contact 1 ? 2 opens briefly. switching from 3 to 4: contact 1 ? 2 remains closed. 1 2 3 4 terminal marking link 0 1 2 contact open contact closed switch position 1 2 3 4 0 1 2 3 4 centre mounting switches, standard 5, 6 black thumb-grip and silver-coloured front plate a page 07/074 control circuit isolators 7, 8 red rotary handle and yellow locking collar black rotary handle and black locking collar lockable in the 0 (off) position a page 07/074 flush mounting switches, standard 9, 10 black thumb-grip and silver-coloured front plate a page 07/074 standard switches for distribution board mounting (.../ivs) 11 mounting in service distribution boards mounting width: 2 space units (45 mm mounting depth) up to 2 contact units a page 07/074 switch position reliable switching due to indexing mechanism switching angles 30 , 45 , 60 , 90 automatic return with up to 6 contacts complete rotation switching angle of 360 allows complete rotation in both directions moeller hpl0211-2001/2002 tm mini rotary switches control circuit isolators, on-off switches rotary switches switch-disconnectors 07/074 circuit diagram front plate no. no. of poles flush mounting front ip65 centre mounting front ip65 service distribution board mounting front ip30 type price type price type price article no. see price list article no. see price list article no. see price list control circuit isolators, 90 with padlocking facility, lockable in the off position up to 250 v ac per contact 1 tm-1-8290/e/svb 045477 ? ? tm-1-8290/e/svb-sw 215351 ? ? 2 tm-1-8291/e/svb 045478 ? ? tm-1-8291/e/svb-sw 215352 ? ? 3 tm-2-8292/e/svb 045484 ? ? tm-2-8292/e/svb-sw 210955 ? ? 3+n tm-2-8293/e/svb 045485 ? ? tm-2-8293/e/svb-sw 215353 ? ? 6 tm-3-8326/e/svb 045498 ? ? tm-3-8326/e/svb-sw 215354 ? ? on-off switches, 90 1 tm-1-8290/e 070131 tm-1-8290/ez 000693 tm-1-8290/ivs 225334 2 tm-1-8291/e 072504 tm-1-8291/ez 015073 tm-1-8291/ivs 225335 3 tm-2-8292/e 074877 tm-2-8292/ez 015096 tm-2-8292/ivs 225336 3+n tm-2-8293/e 077250 tm-2-8293/ez 045486 tm-2-8293/ivs 225337 6 tm-3-8326/e 079623 tm-3-8326/ez 045499 ? standard pack: 1 off 0 1 2 1 0 1 2 1 4 3 0 1 2 13 4 5 6 0 1 2 1 3 4 5 6 7 8 2 13 4 5 6 7 8 9 10 11 12 0 1 2 1 0 1 1 0 f 056 2 13 4 0 1 1 0 f 056 2 13 4 5 6 0 1 1 0 f 056 2 13 4 5 6 7 8 0 1 1 0 f 056 2 13 4 5 6 7 8 9 10 11 12 0 1 1 0 f 056 rotary switches switch-disconnectors 07/075 moeller hpl0211-2001/2002 tm mini rotary switches control switches: changeover switches circuit diagram front plate no. no. of poles flush mounting front ip65 centre mounting front ip65 service distribution board mounting front ip30 type price type price type price article no. see price list article no. see price list article no. see price list changeover switches without 0 (off) position, 60 1 tm-1-8220/e 081996 tm-1-8220/ez 000692 tm-1-8220/ivs 225338 2 tm-2-8221/e 084369 tm-2-8221/ez 015197 tm-2-8221/ivs 225339 3 tm-3-8222/e 086742 tm-3-8222/ez 045493 ? 4 tm-4-8223/e 089115 tm-4-8223/ez 046119 ? 5 tm-5-8369/e 091488 tm-5-8369/ez 046126 ? 6 tm-6-8370/e 093861 tm-6-8370/ez 046130 ? changeover switches with 0 (off) position, 60 1 tm-1-8210/e 096234 tm-1-8210/ez 015137 tm-1-8210/ivs 225340 2 tm-2-8211/e 098607 tm-2-8211/ez 015166 tm-2-8211/ivs 225341 3 tm-3-8212/e 010807 tm-3-8212/ez 045491 ? 4 tm-4-8213/e 013180 tm-4-8213/ez 045847 ? standard pack: 1 off 2 13 4 1 2 f 072 12 2 13 4 5 6 7 8 1 2 f 072 12 2 13 4 5 6 7 8 9 10 11 12 1 2 f 072 12 2 13 4 5 6 7 8 9 10 11 12 13 15 16 14 1 2 f 072 12 2 13 4 5 6 7 8 9 10 11 12 13 15 16 14 17 19 20 18 1 2 f 072 12 1 2 2 13 4 5 6 7 8 9 10 11 12 13 15 16 14 17 19 20 18 21 22 24 23 f 072 12 2 13 4 2 0 1 f 071 1 2 0 2 2 13 4 5 6 7 8 0 1 f 071 1 2 0 2 13 4 5 6 7 8 9 10 11 12 1 0 2 f 249 1 0 2 2 13 4 5 6 7 8 9 10 11 12 13 15 16 14 1 0 2 f 249 1 0 2 moeller hpl0211-2001/2002 tm mini rotary switches control switches: changeover switches, hand/auto switches rotary switches switch-disconnectors 07/076 circuit diagram front plate no. no. of poles flush mounting front ip65 centre mounting front ip65 service distribution board mounting front ip30 type price type price type price article no. see price list article no. see price list article no. see price list changeover switches with 0 (off) position, 90 1 tm-1-8218/e 015553 tm-1-8218/ez 045476 ? 2 tm-2-8219/e 017926 tm-2-8219/ez 045482 ? 3 tm-3-8299/e 020299 tm-3-8299/ez 045497 ? 3+n tm-4-8294/e 022672 tm-4-8294/ez 046121 ? hand/auto switches, 60 1 ? tm-1-8220 f288/ez 016925 ? 1 tm-1-15431/e 025045 tm-1-15431/ez 000691 tm-1-15431/ivs 225342 2 tm-2-15432/e 027418 tm-2-15432/ez 016878 tm-2-15432/ivs 225343 3 tm-3-15433/e 029791 tm-3-15433/ez 045490 ? changeover switches with spring-return from both directions, 30 1 tm-1-8214/e 032164 tm-1-8214/ez 016673 ? 2 tm-2-8215/e 034537 tm-2-8215/ez 045481 ? 3 tm-3-8216/e 036910 tm-3-8216/ez 045492 ? standard pack: 1 off 2 13 4 2 0 1 f 057 0 1 2 2 13 4 5 6 7 8 2 0 1 f 057 0 1 2 2 13 4 5 6 7 8 9 10 11 12 2 0 1 f 057 0 1 2 2 13 4 5 6 7 8 9 10 11 12 13 15 16 14 2 0 1 f 057 0 1 2 2 13 4 auto hand f 288 hand autom 2 13 4 hand auto 0 f 085 0 hand auto 0 auto hand 2 13 4 5 6 7 8 f 085 0 hand auto auto hand 0 2 13 4 5 6 7 8 9 10 11 12 f 085 0 hand auto 2 13 4 1 0 2 f 025 0 1 2 2 13 4 5 6 7 8 1 0 2 f 025 0 1 2 2 13 4 5 6 7 8 9 10 11 12 1 0 2 f 025 0 1 2 rotary switches switch-disconnectors 07/077 moeller hpl0211-2001/2002 tm mini rotary switches control switches: step switches circuit diagram front plate no. no. of poles flush mounting front ip65 centre mounting front ip65 service distribution board mounting front ip30 type price type price type price article no. see price list article no. see price list article no. see price list step switches without 0 (off) position, 60 3 steps 1 tm-2-8230/e 039283 tm-2-8230/ez 000701 tm-2-8230/ivs 225344 3 tm-5-8270/e 041656 tm-5-8270/ez 046124 4 steps 1 tm-2-8231/e 044029 tm-2-8231/ez 000700 tm-2-8231/ivs 225345 3 tm-6-8271/e 046402 tm-6-8271/ez 046128 standard pack: 1 off 2 13 4 5 6 3 2 1 f 076 2 1 3 2 13 4 5 6 7 8 9 10 11 12 13 15 16 14 17 18 3 2 1 f 076 2 1 3 2 13 4 5 6 7 8 1 2 3 4 f 077 2 1 3 4 2 13 4 5 6 7 8 9 10 11 12 13 15 16 14 17 19 20 18 21 22 24 23 1 2 3 4 f 077 2 1 3 4 moeller hpl0211-2001/2002 tm mini rotary switches control switches: step switches rotary switches switch-disconnectors 07/078 circuit diagram front plate no. no. of poles flush mounting front ip65 centre mounting front ip65 type price type price article no. see price list article no. see price list step switches without 0 (off) position 5 steps, 60 1 tm-3-8232/e 039298 tm-3-8232/ez 015592 2 tm-5-8252/e 041671 tm-5-8252/ez 046123 6 steps, 60 without complete rotation 1 tm-3-8233/e 053521 tm-3-8233/ez 015630 2 tm-6-8253/e 055894 tm-6-8253/ez 046127 10 steps, 30 1 tm-5-8237/e 069150 tm-5-8237/ez 015661 standard pack: 1 off 3 2 1 4 5 2 13 4 5 6 7 8 9 10 f 078 2 1 3 4 5 3 2 1 4 5 2 13 4 5 6 7 8 9 10 11 12 13 15 16 14 17 19 20 18 f 078 2 1 3 4 5 2 13 4 5 6 7 8 9 10 11 12 3 2 1 4 5 6 2 1 3 4 5 6 f 079 2 13 4 5 6 7 8 9 10 11 12 13 15 16 14 17 19 20 18 21 22 24 23 3 2 1 4 5 6 2 1 3 4 5 6 f 079 3 2 1 4 5 6 7 8 9 10 2 13 4 5 6 7 8 9 10 11 12 13 15 16 14 17 19 20 18 f 011 1 2 3 4 5 6 7 8 9 10 rotary switches switch-disconnectors 07/079 moeller hpl0211-2001/2002 tm mini rotary switches control switches: step switches circuit diagram front plate no. no. of poles flush mounting front ip65 centre mounting front ip65 type price type price article no. see price list article no. see price list step switches with additional 0 (off) position 2 steps, 60 1 tm-1-8240/e 058267 tm-1-8240/ez 015226 2 tm-2-8260/e 060640 tm-2-8260/ez 045483 3 tm-3-8280/e 063013 tm-3-8280/ez 045496 3 steps, 45 1 tm-2-8241/e 065386 tm-2-8241/ez 015256 2 tm-3-8261/e 067759 tm-3-8261/ez 000698 3 tm-5-8281/e 070132 tm-5-8281/ez 046125 4 steps, 30 1 tm-2-8242/e 072505 tm-2-8242/ez 015506 2 tm-4-8262/e 074878 tm-4-8262/ez 046120 3 tm-6-8282/e 077251 tm-6-8282/ez 046129 standard pack: 1 off 2 13 4 2 1 0 f 075 1 0 2 2 13 4 5 6 7 8 2 1 0 f 075 1 0 2 2 13 4 5 6 7 8 9 10 11 12 2 1 0 f 075 1 0 2 2 13 4 5 6 3 2 1 0 f 109 0 1 2 3 2 13 4 5 6 7 8 9 10 11 12 3 2 1 0 f 109 0 1 2 3 2 13 4 5 6 7 8 9 10 11 12 13 15 16 14 17 18 3 2 1 0 f 109 0 1 2 3 2 13 4 5 6 7 8 1 2 3 4 0 f 002 0 1 2 3 4 2 13 4 5 6 7 8 9 10 11 12 13 15 16 14 1 2 3 4 0 f 002 0 1 2 3 4 2 13 4 5 6 7 8 9 10 11 12 13 15 16 14 17 19 20 18 21 22 24 23 1 2 3 4 0 f 002 0 1 2 3 4 moeller hpl0211-2001/2002 tm mini rotary switches control switches: step switches, group switches rotary switches switch-disconnectors 07/080 circuit diagram front plate no. no. of poles flush mounting front ip65 centre mounting front ip65 type price type price article no. see price list article no. see price list step switches with additional 0 (off) position, 30 5 steps 1 tm-3-8243/e 079624 tm-3-8243/ez 015537 6 steps 1 tm-3-8244/e 081997 tm-3-8244/ez 045495 9 steps 1 tm-5-8247/e 009741 tm-5-8247/ez 015565 group switches 2 groups, 60 1 tm-1-8310/e 084370 tm-1-8310/ez 045479 3 groups, 30 1 tm-2-8311/e 086743 tm-2-8311/ez 045487 standard pack: 1 off 2 13 4 5 6 7 8 9 10 3 2 1 4 5 0 f 003 1 2 3 4 5 0 2 13 4 5 6 7 8 9 10 11 12 3 2 1 4 5 0 6 f 004 1 2 3 4 5 6 0 2 13 4 5 6 7 8 9 10 11 12 13 15 16 14 17 18 2 1 0 3 4 5 6 7 8 9 f 007 0 1 2 3 4 5 6 7 8 9 2 13 4 2 1 0 f 075 1 0 2 2 13 4 5 6 2 1 0 3 f 001 1 2 3 0 rotary switches switch-disconnectors 07/081 moeller hpl0211-2001/2002 tm mini rotary switches control switches: on/off switches, spring-return circuit diagram front plate no. no. of poles flush mounting front ip65 centre mounting front ip65 type price type price article no. see price list article no. see price list on/off switches with spring-return, 30 off switches, spring-return 1 tm-1-8174/e 089116 tm-1-8174/ez 016646 on switches, spring-return 1 tm-1-8175/e 091489 tm-1-8175/ez 015690 on-off switches, spring-return 1 tm-1-8176/e 093862 tm-1-8176/ez 016714 2 tm-2-8183/e 096235 tm-2-8183/ez 045480 on-off spring-return switches, 90 /30 with spring-return from start to 1 1 tm-1-8178/e 098608 tm-1-8178/ez 016786 standard pack: 1 off 2 1 stop f 022 stop 2 1 start f 023 start 2 13 4 start stop f 024 stop start 2 13 4 5 6 7 8 start stop f 024 stop start 2 13 4 start 0 1 f 119 start moeller hpl0211-2001/2002 tm mini rotary switches control switches: reversing switches, coding switches rotary switches switch-disconnectors 07/082 circuit diagram front plate no. no. of poles flush mounting front ip65 centre mounting front ip65 type price type price article no. see price list article no. see price list reversing switches with spring-return from start to 1 or 2, 60 /30 1 tm-2-8177/e 010808 tm-2-8177/ez 016838 reversing switches, 60 2 tm-2-8400/e 013181 tm-2-8400/ez 045488 3 tm-3-8401/e 015554 tm-3-8401/ez 045500 reversing switches with spring-return to 0, 30 3 tm-3-8228/e 017927 tm-3-8228/ez 045494 coding switches, bcd code 0 ? 9, 30 1 tm-2-8550/e 020300 tm-2-8550/ez 000699 complementary bcd code 0 ? 9, 30 1 tm-2-8551/e 022673 tm-2-8551/ez 045489 bcd code 0 ? 9 + complement, 30 1 tm-4-8552/e 025046 tm-4-8552/ez 046122 standard pack: 1 off 1 2 0 2 13 4 5 6 7 8 start start 0 2 1 f 121 start start 2 13 4 5 6 7 8 2 0 1 f 071 1 2 0 2 13 4 5 6 7 8 9 10 2 0 1 f 071 1 2 0 2 13 4 5 6 7 8 9 10 1 0 2 f 025 0 1 2 2 13 4 5 6 7 8 2 1 0 3 4 5 6 7 8 9 f 007 0 1 2 3 4 5 6 7 8 9 2 13 4 5 6 7 8 2 1 0 3 4 5 6 7 8 9 f 007 0 1 2 3 4 5 6 7 8 9 2 13 4 5 6 7 8 9 10 11 12 13 15 16 14 2 1 0 3 4 5 6 7 8 9 f 007 0 1 2 3 4 5 6 7 8 9 rotary switches switch-disconnectors 07/083 moeller hpl0211-2001/2002 tm mini rotary switches accessories type price article no. see price list key operation 1) includes two keys kaba lock for 90 switching angle 1) degree of protection ip65 the key can be withdrawn only in specified positions, see diagrams below. however, the kaba lock mechanism for 90 can also be used for other switching angles provided the positions for key withdrawal correspond with those specified for the type of switch. example: +ez/s-b can be used on a step switch having a switching angle of 30, provided the key is to be with- drawn only in the off position at 270. the key is not withdrawable in positions which exceed the total switching angle of the switch. options for key withdrawal for example of position marking see a page 07/111 key withdrawable at: 0 +ez/s-a 045458 270 +ez/s-b 045459 270 + 0 +ez/s-f 045463 0 + 90 +ez/s-e 045462 270 + 0 + 90 +ez/s-r 045471 270 + 0 + 90 + 180 +ez/s-g 045464 ronis lock for 60 switching angle 1) degree of protection ip55 key withdrawable at: 0 + 180 +ez/s-c 045460 270 + 90 +ez/s-d 045461 300 + 0 + 60 + 120 + 180 + 240 +ez/s-h 045465 270 + 330 + 30 + 90 + 150 + 210 +ez/s-j 045466 0 + 60 + 180 + 240 +ez/s-m 045467 270 + 330 + 90 + 150 +ez/s-n 045468 300 + 0 + 120 + 180 +ez/s-p 045469 270 + 30 + 90 + 210 +ez/s-q 045470 standard pack: 1 off 1) for mounting forms e and ez a bf e r g c d h j m n p q 330 0 30 300 270 240 225 210 180 150 135 120 90 60 315 45 moeller hpl0211-2001/2002 t rotary switches t0 non-standard switches rotary switches switch-disconnectors 07/084 type price type price price see price list see price list see price list std. pack t0 rotary switches t0-1-sond.../e t0-5-sond.../e 1 off t0-1-sond.../ea/svb t0-5-sond.../ez t0-1-sond.../ea/svb-sw t0-5-sond.../ez/ofs t0-1-sond.../ez t0-5-sond.../ivs t0-1-sond.../ez/ofs t0-5-sond.../xz t0-1-sond.../i1 t0-5-sond.../z t0-1-sond.../i1/svb t0-1-sond.../i1/svb-sw t0-6-sond.../e t0-1-sond.../ivs t0-6-sond.../ez t0-1-sond.../v/svb t0-6-sond.../ez/ofs t0-1-sond.../v/svb-sw t0-6-sond.../ivs t0-1-sond.../xz t0-6-sond.../xz t0-1-sond.../z t0-6-sond.../z t0-2-sond.../e t0-7-sond.../e t0-2-sond.../ea/svb t0-7-sond.../ez t0-2-sond.../ea/svb-sw t0-7-sond.../ez/ofs t0-2-sond.../ez t0-7-sond.../ivs t0-2-sond.../ez/ofs t0-7-sond.../xz t0-2-sond.../i1 t0-7-sond.../z t0-2-sond.../i1/svb t0-2-sond.../i1/svb-sw t0-8-sond.../e t0-2-sond.../ivs t0-8-sond.../ez t0-2-sond.../v/svb t0-8-sond.../ez/ofs t0-2-sond.../v/svb-sw t0-8-sond.../ivs t0-2-sond.../xz t0-8-sond.../xz t0-2-sond.../z t0-8-sond.../z t0-3-sond.../e t0-9-sond.../e t0-3-sond.../ea/svb t0-9-sond.../ez t0-3-sond.../ea/svb-sw t0-9-sond.../ez/ofs t0-3-sond.../ez t0-9-sond.../ivs t0-3-sond.../ez/ofs t0-9-sond.../xz t0-3-sond.../i1 t0-9-sond.../z t0-3-sond.../i1/svb t0-3-sond.../i1/svb-sw t0-10-sond.../e t0-3-sond.../ivs t0-10-sond.../ez t0-3-sond.../v/svb t0-10-sond.../ez/ofs t0-3-sond.../v/svb-sw t0-10-sond.../ivs t0-3-sond.../xz t0-10-sond.../xz t0-3-sond.../z t0-10-sond.../z t0-4-sond.../e t0-11-sond.../e t0-4-sond.../ea/svb t0-11-sond.../ez t0-4-sond.../ea/svb-sw t0-11-sond.../ez/ofs t0-4-sond.../ez t0-11-sond.../ivs t0-4-sond.../ez/ofs t0-11-sond.../xz t0-4-sond.../i1 t0-11-sond.../z t0-4-sond.../i1/svb t0-4-sond.../i1/svb-sw t0-4-sond.../ivs t0-4-sond.../v/svb t0-4-sond.../v/svb-sw t0-4-sond.../xz t0-4-sond.../z notes these pages show t rotary switches with non- standard contact sequences (-sond...) which are priced accordingly (see price list). use the initial order form on a page 07/112 for ordering any t rotary switch combination. for subsequent orders, state contact sequence number together with country identifer (eg 4711gb) the contact numbers for non-standard contact sequences are: >200 <8000 or >9000 <15000 or >16000. rotary switches switch-disconnectors 07/085 moeller hpl0211-2001/2002 t rotary switches t3 non-standard switches type price type price see price list see price list std. pack t3 rotary switches t3-1-sond.../e t3-5-sond.../e 1 off t3-1-sond.../ea/svb t3-5-sond.../ea/svb t3-1-sond.../ea/svb-sw t3-5-sond.../ea/svb-sw t3-1-sond.../ez t3-5-sond.../ez t3-1-sond.../ez/ofs t3-5-sond.../ez/ofs t3-1-sond.../i2 t3-5-sond.../i2 t3-1-sond.../i2/svb t3-5-sond.../i2/svb t3-1-sond.../i2/svb-sw t3-5-sond.../i2/svb-sw t3-1-sond.../v/svb t3-5-sond.../v/svb t3-1-sond.../v/svb-sw t3-5-sond.../v/svb-sw t3-1-sond.../xz t3-5-sond.../xz t3-1-sond.../z t3-5-sond.../z t3-2-sond.../e t3-6-sond.../e t3-2-sond.../ea/svb t3-6-sond.../ea/svb t3-2-sond.../ea/svb-sw t3-6-sond.../ea/svb-sw t3-2-sond.../ez t3-6-sond.../ez t3-2-sond.../ez/ofs t3-6-sond.../ez/ofs t3-2-sond.../i2 t3-6-sond.../v/svb t3-2-sond.../i2/svb t3-6-sond.../v/svb-sw t3-2-sond.../i2/svb-sw t3-6-sond.../xz t3-2-sond.../v/svb t3-6-sond.../z t3-2-sond.../v/svb-sw t3-2-sond.../xz t3-7-sond.../e t3-2-sond.../z t3-7-sond.../ez t3-7-sond.../ez/ofs t3-3-sond.../e t3-7-sond.../xz t3-3-sond.../ea/svb t3-7-sond.../z t3-3-sond.../ea/svb-sw t3-3-sond.../ez t3-8-sond.../e t3-3-sond.../ez/ofs t3-8-sond.../ez t3-3-sond.../i2 t3-8-sond.../ez/ofs t3-3-sond.../i2/svb t3-8-sond.../xz t3-3-sond.../i2/svb-sw t3-8-sond.../z t3-3-sond.../v/svb t3-3-sond.../v/svb-sw t3-9-sond.../e t3-3-sond.../xz t3-9-sond.../ez t3-3-sond.../z t3-9-sond.../ez/ofs t3-9-sond.../xz t3-4-sond.../e t3-9-sond.../z t3-4-sond.../ea/svb t3-4-sond.../ea/svb-sw t3-10-sond.../e t3-4-sond.../ez t3-10-sond.../ez t3-4-sond.../ez/ofs t3-10-sond.../ez/ofs t3-4-sond.../i2 t3-10-sond.../xz t3-4-sond.../i2/svb t3-10-sond.../z t3-4-sond.../i2/svb-sw t3-4-sond.../v/svb t3-11-sond.../e t3-4-sond.../v/svb-sw t3-11-sond.../ez t3-4-sond.../xz t3-11-sond.../ez/ofs t3-4-sond.../z t3-11-sond.../xz t3-11-sond.../z moeller hpl0211-2001/2002 t rotary switches t5b non-standard switches rotary switches switch-disconnectors 07/086 type price type price see price list see price list std. pack t5b rotary switches t5b-1-sond.../e t5b-5-sond.../e 1 off t5b-1-sond.../ea/svb t5b-5-sond.../ea/svb t5b-1-sond.../ea/svb-sw t5b-5-sond.../ea/svb-sw t5b-1-sond.../i4 t5b-5-sond.../v/svb t5b-1-sond.../i4/svb t5b-5-sond.../v/svb-sw t5b-1-sond.../i4/svb-sw t5b-5-sond.../x t5b-1-sond.../v/svb t5b-5-sond.../z t5b-1-sond.../v/svb-sw t5b-1-sond.../x t5b-6-sond.../e t5b-1-sond.../z t5b-6-sond.../ea/svb t5b-6-sond.../ea/svb-sw t5b-2-sond.../e t5b-6-sond.../v/svb t5b-2-sond.../ea/svb t5b-6-sond.../v/svb-sw t5b-2-sond.../ea/svb-sw t5b-6-sond.../x t5b-2-sond.../i4 t5b-6-sond.../z t5b-2-sond.../i4/svb t5b-2-sond.../i4/svb-sw t5b-7-sond.../e t5b-2-sond.../v/svb t5b-7-sond.../ea/svb t5b-2-sond.../v/svb-sw t5b-7-sond.../ea/svb-sw t5b-2-sond.../x t5b-7-sond.../v/svb t5b-2-sond.../z t5b-7-sond.../v/svb-sw t5b-7-sond.../x t5b-3-sond.../e t5b-7-sond.../z t5b-3-sond.../ea/svb t5b-3-sond.../ea/svb-sw t5b-8-sond.../e t5b-3-sond.../i4 t5b-8-sond.../ea/svb t5b-3-sond.../i4/svb t5b-8-sond.../ea/svb-sw t5b-3-sond.../i4/svb-sw t5b-8-sond.../v/svb t5b-3-sond.../v/svb t5b-8-sond.../v/svb-sw t5b-3-sond.../v/svb-sw t5b-8-sond.../x t5b-3-sond.../x t5b-8-sond.../z t5b-3-sond.../z t5b-9-sond.../e t5b-4-sond.../e t5b-9-sond.../x t5b-4-sond.../ea/svb t5b-9-sond.../z t5b-4-sond.../ea/svb-sw t5b-4-sond.../i4 t5b-10-sond.../e t5b-4-sond.../i4/svb t5b-10-sond.../x t5b-4-sond.../i4/svb-sw t5b-10-sond.../z t5b-4-sond.../v/svb t5b-4-sond.../v/svb-sw t5b-4-sond.../x t5b-4-sond.../z notes these pages show t rotary switches with non- standard contact sequences (-sond...) which are priced accordingly (see price list). use the initial order form on a page 07/112 for ordering any t rotary switch combination. for subsequent orders, state contact sequence number together with country identifer (eg 4711gb) the contact numbers for non-standard contact sequences are: >200 <8000 or >9000 <15000 or >16000. rotary switches switch-disconnectors 07/087 moeller hpl0211-2001/2002 t rotary switches t5 non-standard switches type price type price see price list see price list std. pack t5 rotary switches t5-1-sond.../e t5-5-sond.../e 1 off t5-1-sond.../ea/svb t5-5-sond.../ea/svb t5-1-sond.../ea/svb-sw t5-5-sond.../ea/svb-sw t5-1-sond.../i5 t5-5-sond.../v/svb t5-1-sond.../i5/svb t5-5-sond.../v/svb-sw t5-1-sond.../i5/svb-sw t5-5-sond.../x t5-1-sond.../v/svb t5-5-sond.../z t5-1-sond.../v/svb-sw t5-1-sond.../x t5-6-sond.../e t5-1-sond.../z t5-6-sond.../ea/svb t5-6-sond.../ea/svb-sw t5-2-sond.../e t5-6-sond.../v/svb t5-2-sond.../ea/svb t5-6-sond.../v/svb-sw t5-2-sond.../ea/svb-sw t5-6-sond.../x t5-2-sond.../i5 t5-6-sond.../z t5-2-sond.../i5/svb t5-2-sond.../i5/svb-sw t5-7-sond.../e t5-2-sond.../v/svb t5-7-sond.../ea/svb t5-2-sond.../v/svb-sw t5-7-sond.../ea/svb-sw t5-2-sond.../x t5-7-sond.../v/svb t5-2-sond.../z t5-7-sond.../v/svb-sw t5-7-sond.../x t5-3-sond.../e t5-7-sond.../z t5-3-sond.../ea/svb t5-3-sond.../ea/svb-sw t5-8-sond.../e t5-3-sond.../i5 t5-8-sond.../ea/svb t5-3-sond.../i5/svb t5-8-sond.../ea/svb-sw t5-1-sond.../i5/svb-sw t5-8-sond.../v/svb t5-3-sond.../v/svb t5-8-sond.../v/svb-sw t5-3-sond.../v/svb-sw t5-8-sond.../x t5-3-sond.../x t5-8-sond.../z t5-3-sond.../z t5-9-sond.../e t5-4-sond.../e t5-9-sond.../x t5-4-sond.../ea/svb t5-9-sond.../z t5-4-sond.../ea/svb-sw t5-4-sond.../i5 t5-10-sond.../e t5-4-sond.../i5/svb t5-10-sond.../x t5-4-sond.../i5/svb-sw t5-10-sond.../z t5-4-sond.../v/svb t5-4-sond.../v/svb-sw t5-4-sond.../x t5-4-sond.../z moeller hpl0211-2001/2002 t rotary switches tm non-standard switches, bulk packaged switches rotary switches switch-disconnectors 07/088 type 1) price type 2) price see price list see price list std. pack tm mini rotary switches tm-1-sond.../e tm-1-sond-erstbestellung/e 1 off tm-1-sond.../ez tm-1-sond-erstbestellung/ez tm-1-sond.../ivs tm-1-sond-erstbestellung/ivs tm-2-sond.../e tm-2-sond-erstbestellung/e tm-2-sond.../ez tm-2-sond-erstbestellung/ez tm-2-sond.../ivs tm-2-sond-erstbestellung/ivs tm-3-sond.../e tm-3-sond-erstbestellung/e tm-3-sond.../ez tm-3-sond-erstbestellung/ez tm-4-sond.../e tm-4-sond-erstbestellung/e tm-4-sond.../ez tm-4-sond-erstbestellung/ez tm-5-sond.../e tm-5-sond-erstbestellung/e tm-5-sond.../ez tm-5-sond-erstbestellung/ez tm-6-sond.../e tm-6-sond-erstbestellung/e tm-6-sond.../ez tm-6-sond-erstbestellung/ez tm-7-sond.../e tm-7-sond-erstbestellung/e tm-7-sond.../ez tm-7-sond-erstbestellung/ez tm-8-sond.../e tm-8-sond-erstbestellung/e tm-8-sond.../ez tm-8-sond-erstbestellung/ez notes 1) for subsequent orders, for which the design number is known. form fo2 is not required for these. 2) for initial orders. form fo2 has to be completed and submitted for these. type price article no. see price list std. pack bulk packaged switches t0-2-1/ea/svb-gvp50 217168 50 off p1-25/ea/svb-gvp50 217370 50 off p1-32/ea/svb-gvp50 217169 50 off p3-63/ea/svb-gvp25 218130 25 off p3-100/ea/svb-gvp25 218132 25 off rotary switches switch-disconnectors 07/089 moeller hpl0211-2001/2002 t rotary switches fitting rotary switches with coupling (t.../z or t.../v/svb) into enclosures notes ci-k... insulated enclosures are enclosures specifically designed for the installation of rotary switches, such as t0, t5b and t5 with up to 4 contact units = 8 contacts, t3 with up to 5 contact units = 10 contacts. they have a high degree of protection and up to 5 cable entries. if more than 5 cables or large cross-section cables are to be connected, then we recommend the use of insulated enclosures from the ci system. 1) select the required switch and determine the cables to be connected. 2) select an enclosure ( a hpl0214-2001) according to the minimum mounting depth of the switch. this depth dimension has to be less than or equal to the internal mounting depth of the enclosure. in addition, the quantity and size of the cable entries must be taken into account. use the tables below to determine whether, and if so how many, zav-... shaft extensions are required and, for .../svb switches, the identical quantity of zvv-... interlock extensions. example: switch: t3-6-.../v/svb minimum mounting depth: t...-6/z = 147 mm extensions: no extension is required for an enclosure having a mounting depth of 150 mm. two zav-t0 shaft extensions and two zvv-t0 interlock extensions are required for an enclosure having a mounting depth of 200 mm. t0-... mounting depths t3-... mounting depths t5(b)-... mounting depths dimensions in mm with extension without/ with zav-t0 without/ with zav-t0 without/ with zav-p3 number +1 +2 +3 +4 +1 +2 +3 +4 +1 +2 +3 +4 switch type from to to to to to from to to to to to from to to to to to t...-1-.../z(v/svb) 86 102 127 152 177 202 89 105 130 155 180 205 92 107 132 157 182 207 t...-2-.../z(v/svb) 96 112 137 162 187 212 101 116 141 166 191 216 109 124 149 174 199 224 t...-3-.../z(v/svb) 105 121 146 171 196 221 112 128 153 178 203 228 125 140 165 190 215 240 t...-4-.../z(v/svb) 115 131 156 181 206 231 124 139 164 189 214 239 142 157 182 207 232 257 t...-5-.../z(v/svb) 124 140 165 190 215 240 135 151 176 201 226 251 158 173 198 223 248 273 t...-6-.../z(v/svb) 134 150 175 200 225 250 147 162 187 212 237 262 175 190 215 240 265 290 t...-7-.../z(v/svb) 143 159 184 209 234 259 158 174 199 224 249 274 191 206 231 256 281 306 t...-8-.../z(v/svb) 153 169 194 219 244 269 170 185 210 235 260 285 208 223 248 273 298 323 t...-9-.../z(v/svb) 162 178 203 228 253 278 181 197 222 247 272 297 224 239 264 289 314 339 t...-10-.../z(v/svb) 172 188 213 238 263 288 193 208 233 258 283 308 241 256 281 306 331 356 t...-11-.../z(v/svb) 181 197 222 247 272 279 204 220 245 270 295 320 moeller hpl0211-2001/2002 t rotary switches technical data rotary switches switch-disconnectors 07/090 t0-... t3-... t5b-... t5-... t6-... (t6-160-6) t8-... general technical data standards iec/en 60 947, iec/en 60 204, csa, ul switch-disconnector to iec/en 60 947-3 load-break switch to iec/en 60 947-3 shipping classifications a sk0200-1043 lifespan, mechanical max. operating frequency operations ops./h > 10 6 3000 5 x 10 5 3000 5 x 10 5 3000 5 x 10 5 3000 > 10 5 50 > 10 5 50 climatic proofing damp heat, constant, to iec 60 068 part 2-3 damp heat, cyclical, to iec 60 068 part 2-30 ambient temperature open min./max. c ? 25/+50 ? 25/+50 ? 25/+50 ? 25/+50 ? 25/+50 ? 25/+50 enclosed min./max. c ? 25/+40 ? 25/+40 ? 25/+40 ? 25/+40 ? 25/+40 ? 25/+40 mounting position as required dimensions a page 07/096 a page 07/101 a page 07/103 weight a page 15/023 mechanical shock resistance (shock duration 20 ms) g > 15 > 15 4) > 15 > 15 > 15 ? contacts rated operational voltage u e v ac 690 690 690 690 690 690 rated impulse withstand voltage u imp v 6000 6000 6000 6000 6000 (8000) 2) 8000 overvoltage category/pollution degree iii/3 iii/3 iii/3 iii/3 iii/3 iii/3 rated uninterrupted current i u with max. cable connected a 20 32 63 100 5) 125 (160) 2) 315 6) load-carrying capacity in intermittent operation, class 12, ab 60/40/25 % df 1.3/1.6/2 x i e short-circuit rating maximum fuse a gg/gl 20 25 80 100 200 (160) 2) 315 rated short-time withstand current (1 s current) i cw a rms 320 650 1300 1850 2000 (3000) 2) 4200 safe isolation to iec 536 between the contacts v ac 440 440 440 440 ? ? protection against direct contact finger and back-of-hand proof to iec 536 ? ? switching angles 90/60/45/30 90/60 60 (90) 3 contact units max. 11 11 10 10 3 3 double-break contacts max. 22 22 20 20 6 6 current heat loss per contact at i e w 0.6 1.1 4.5 7.5 11 11 terminal capacity solid or stranded 1) mm 2 1 x (1 ? 2.5) 1 x (1 ? 6) 1 x (2.5 ? 35) 1 x (2.5 ? 35) 1 x 70 (95) 2) 150 mm 2 2 x (1 ? 2.5) 2 x ( 1 ? 6) 2 x (2.5 ? 16) 2 x (2.5 ? 16) 2 x 25 ? flexible with ferrule 1) (ferrule to din 46 228) mm 2 1 x (0.75 ? 1.5) 1 x (0.75 ? 4) 1 x (1.5 ? 25) 1 x (1.5 ? 25) 1 x 50 (50) 2) 120 mm 2 2 x (0.75 ? 1.5) 2 x (0.75 ? 4) 2 x (1.5 ? 10) 2 x (1.5 ? 10) 2 x 16 ? flat conductor connection mm 2 ? ? ? ? ? 1 busbar 25 x 5 3) 2 busbars 20 x 3 3) terminal screw m3.5 m4 m6 m6 (counter- sunk m5) 2) m12 max. tightening torque nm 1 1.5 4 5.6 (14) 2) 25 t0-1-... to t0-4-... t3-1- to t3-6- t5b-... t5-... t6-... (t6-160-6) t8-3-8342 switch-disconnector (main switches) switching angles 90 90 90 90 90 90 max. number of switch positions 2 2 2 2 2 2 max. number of contacts for isolating characteristics to iec/en 60 947 8 12 20 20 3 (6) 2) 6 isolating characteristics to iec/en 60 947 up to v ac 500 500 690 690 690 690 notes 1) t0(3), (6), (8)...: max. 2 cross-section sizes difference admissible between 2 conductors t5(b)-...: max. 1 cross-section size difference admissible between 2 conductors 2) for t6-160-6/... 3) for t8-3-8342/... 4) t3-.../i... > 12 g 5) t5-4-8344/i5: max. 95 a 6) enclosed version: max. 275 a rotary switches switch-disconnectors 07/091 moeller hpl0211-2001/2002 t rotary switches technical data t0-... t3-... t5b-... t5-... t6-... (t6-160-6) t8-... switching capacity ac rated making capacity cos v = 0.35 a 130 320 800 950 1600 2390 rated breaking capacity 230 v ac, cos v = 0.35 a 100 260 520 760 1280 1910 motor load switches 400 v ac, cos v = 0.35 a 110 260 600 740 900 1800 500 v ac, cos v = 0.35 a 80 240 480 590 880 1200 690 v ac, cos v = 0.35 a 60 170 340 420 340 420 ac-21a load-break switches rated operational current i e 380 ? 440 v, 3 h a 20 32 63 100 125 (160) 315 ac-3 motor load switches, for operational switching star-delta values y d : for star-delta switches without automatic spring-return 220 ? 240 v, 3 h kw 3 6.5 15 18.5 22 37 220 ? 240 v, y d kw 4 11 22 30 22 37 380 ? 440 v, 3 h kw 4 12 22 30 37 (45) 55 380 ? 440 v, y d kw 5.5 18.5 37 45 37 (45) 55 500 v, 3 h kw 5.5 15 22 37 37 37 500 v, y d kw 7.5 22 37 55 37 37 660/690 v, 3 h kw 4 15 22 30 22 37 660/690 v, y d kw 5.5 22 37 45 22 37 ac-23a motor load switches (main switches, maintenance switches) 220 ? 240 v, 3 h kw 3.5 7.5 18.5 18.5 37 75 380 ? 440 v, 3 h kw 6.5 13 22 30 45 (55) 132 500 v, 3 h kw 7.5 15 22 37 55 75 660/690 v, 3 h kw ? ? 22 30 30 37 ac-15 control switches rated operational current i e 220 ? 240/380 ? 415/500 v a 6/4/2 10/6/4 16/6/4 16/6/4 ? ? dc dc-1 load-break switches l/r = 1 ms rated operational current i e a 10 25 63 80 125 315 voltage per contact pair in series v 60 60 60 60 42 42 dc-21a 240 v a 1(1) 1(1) ? ? ? ? dc-23a motor load switches l/r = 15 ms figures in brackets: number of contacts to be switched in series 24 v a 10 (1) 25 (1) 50 (1) ? 125 (1) 250 (1) 48 v a 10 (2) 25 (2) 50 (2) ? 125 (2) 250 (2) 60 v a 10 (3) 25 (3) 50 (3) ? 125 (3) 125 (3) 120 v a 5(3) 12 (3) 25 (3) ? 50 (3) 50 (3) 240 v a 5(5) 10 (5) 20 (6) ? ? ? dc-13 control switches l/r = 50 ms rated operational current i e a 10 20 25 ? 125 250 voltage per contact pair in series v 32 32 24 ? 24 ? control circuit reliability at 24 v dc, 10 ma fault probability h f < 10 ? 5 , < 1 fault in 100000 operations t6-160-6/... t8-3-8342/... auxiliary contacts standards control circuit isolator to iec/en 60 947-5 rated insulation voltage u i v ac 500 rated uninterrupted current i u with max. cable connected a 10 rated operational current i e ac-15 with 220 ?240/380 ? 415/500 v a 6/4/3 short-circuit rating without welding, max. fuse a gg/gl 10 terminal capacity min. solid or flexible mm 2 0.75/0.5 max. solid or flexible mm 2 2.5/1.5 max. tightening torque nm 0.35 control circuit reliability at 24 v dc, 10 ma fault probability h f < 10 ? 5 , < 1 fault in 100 000 operations moeller hpl0211-2001/2002 p switch-disconnectors technical data rotary switches switch-disconnectors 07/092 p1-25 p1-32 p3-63 p3-100 general technical data standards iec/en 60 947, vde 0660, iec/en 60 204, csa, ul switch-disconnector to iec/en 60 947-3 lifespan, mechanical operations 3 x 10 5 3 x 10 5 10 5 10 5 max. operating frequency ops./h 50 50 50 50 climatic proofing damp heat, constant, to iec 60 068 part 2-3 damp heat, cyclical, to iec 60 068 part 2-30 ambient temperature open min./max. c ? 25/+50 ? 25/+50 ? 25/+50 ? 25/+50 enclosed min./max. c ? 25/+40 ? 25/+40 ? 25/+40 ? 25/+40 mounting position as required dimensions a page 07/104 weight a page 15/023 mechanical shock resistance (half-sinusoidal shock 20 ms) g > 20 > 20 > 20 > 20 contacts rated operational voltage u e v ac 690 690 690 690 rated impulse withstand voltage u imp v 6000 6000 6000 6000 overvoltage category/pollution degree iii/3 iii/3 iii/3 iii/3 rated uninterrupted current i u with max. cable connected a 25 32 63 100 load-carrying capacity in intermittent operation, class 12, ab 60/40/25 % df x i e 1.3/1.6/2 1.3/1.6/2 1.3/1.6/2 1.3/1.6/2 short-circuit rating max. fuse a gg/gl 25 50 80 100 rated short-time withstand current (1 s current) i cw a rms 640 640 1260 2000 isolating characteristics to iec/en 60 947 up to vac 690 690 690 690 safe isolation to iec 536 between the main contacts and the auxiliary contacts v ac 440 440 440 440 protection against direct contact finger and back-of-hand proof to iec 536 switching angles 90 90 90 90 contacts (current paths) max. 3(+n) 3(+n) 3(+n) 3(+n) current heat loss per contact at i e w 1.1 1.8 4.5 7.5 terminal capacity solid or stranded 1) mm 2 1 (1.5 ? 6) 1 (1.5 ? 6) 1 (2.5 ? 35) 1 (2.5 ? 35) mm 2 2 (1.5 ? 6) 2 (1.5 ? 6) 2 (2.5 ? 10) 2 (2.5 ? 10) flexible with ferrule 1) (ferrule to din 46 228) mm 2 1 (1 ? 4) 1 (1 ? 4) 1 (1.5 ? 25) 1 (1.5 ? 25) mm 2 2 (1 ? 4) 2 (1 ? 4) 2 (1.5 ? 6) 2 (1.5 ? 6) terminal screw m4 m4 m5 m5 max. tightening torque nm 1.6 1.6 4 4 notes main switch characteristics to iec/en 60 204; positive opening of contacts, operator element positively located on shaft 1) p1-...: max. 2 cross-section sizes difference admissible when using 2 conductors p3-...: max. 1 cross-section size difference admissible when using 2 conductors rotary switches switch-disconnectors 07/093 moeller hpl0211-2001/2002 p switch-disconnectors technical data p1-25 p1-32 p3-63 p3-100 switching capacity ac rated making capacity cos v = 0.35 a 240 320 800 950 rated breaking capacity 230 v ac, cos v = 0.35 a 190 260 640 760 motor load switches 400 v ac, cos v = 0.35 a 150 300 600 740 500 v ac, cos v = 0.35 a 170 290 590 880 690 v ac, cos v = 0.35 a 150 250 340 520 ac-21a load-break switches rated operational current i e 380 ? 440 v, 3 h a 25 32 63 100 ac-3 motor load switches, for operational switching 220 ? 240 v, 3 h kw 5.5 7.5 15 22 380 ? 440 v, 3 h kw 7.5 13 30 37 500 v, 3 h kw 7.5 18.5 30 45 660/690 v, 3 h kw 7.5 15 30 37 ac-23a motor load switches (main switches, maintenance switches) 220 ? 240 v, 3 h kw 7 8.5 18.5 30 380 ? 440 v, 3 h kw 13 15 37 50 500 v, 3 h kw 11 18.5 37 65 660/690 v, 3 h kw 11 18.5 30 75 dc dc-1 load-break switches l/r = 1 ms rated operational current i e a 25 32 63 100 voltage per contact pair in series v 60 60 60 60 dc-23a motor load switches l/r = 15 ms figures in brackets: number of contacts to be switched in series 24 v a 25 (1) 25 (1) 50 (1) 50 (1) 48 v a 25 (2) 25 (2) 50 (2) 50 (2) 60 v a 25 (3) 25 (3) 50 (3) 50 (3) 120 v a 12 (3) 12 (3) 25 (3) 25 (3) n-p1... n-p3... switched neutral switching capacity as p1-32 as p3-100 hi11-p1/p3 auxiliary contacts standards control circuit isolator to iec/en 60 947-5 rated insulation voltage u i v ac 500 rated uninterrupted current i u with max. cable connected a 10 rated operational current i e ac-15 220 ? 240/380 ? 415/500 v a 6/4/3 dc-13 250 v dc a 0.55 125 v dc a 1.1 short-circuit rating without welding, max. fuse a gg/gl 10 terminal capacity min. solid or flexible mm 2 0.75/0.5 max. solid or flexible mm 2 2.5/1.5 max. tightening torque nm 0.6 control circuit reliability at 24 v dc, 10 ma fault probability h f < 10 ? 5 , < 1 fault in 100 000 operations moeller hpl0211-2001/2002 t rotary switches, p switch-disconnectors tripping characteristics rotary switches switch-disconnectors 07/094 component lifespan in relation to breaking current and utilization category 1) in order to achieve a reasonable lifespan in utilization category ac-4 (severe duty: 100 % inching, reversing or plugging), the stalled motor current should not exceed the rated current of the switch at ac-21. notes 1) ac-3 and ac-21 at 400 v, ac-15 at 230 v 1 2 3 4 5 6 7 8 10 20 a t0 0.5 1 2 3 4 5 6 8 10 component lifespan (operations 10 ) 5 breaking point as control switch (ac-15) as motor load switch (ac-3) as load-break switch (ac-21) breaking point as motor load switch (ac-3) as load-break switch (ac-21) t3 component lifespan (operations 10 ) 5 1 2346 12 8 30 40 a 0.5 1 2 3 4 5 6 8 10 16 20 25 0.6 0.8 breaking point as motor load switch (ac-3) as load-break switch (ac-21) t5b, t5 component lifespan (operations 10 ) 5 1 2346 12 83040 0.5 1 2 3 4 5 6 8 10 16 20 0.6 0.8 60 80 100 a t5b t5b t5 t5 t5b t5 t5b t5 breaking point as motor load switch (ac-3) as load-break switch (ac-21) t6, t8 component lifespan (operations 10 ) 5 468 16 12 0.1 0.2 0.3 0.5 1 2 3 5 60 20 30 40 100 250a t6 t8 t6 t8 t6 t8 t6 t8 breaking point as motor load switch (ac-3) as load-break switch (ac-21) p1 component lifespan (operations 10 ) 5 1 2346 12 8 30 40 a 0.5 1 2 3 4 5 6 8 10 16 20 25 0.6 0.8 p1-32 p1-25 p1-25 p1-32 p1-25 breaking point as motor load switch (ac-3) as load-break switch (ac-21) p3 component lifespan (operations 10 ) 5 1 2 35 20 10 80 100 a 0.1 40 60 0.2 0.3 0.4 0.5 0.6 0.8 1 2 p3-100 p3-63 p3-63 p3-100 p3-100 p3-63 rotary switches switch-disconnectors 07/095 moeller hpl0211-2001/2002 tm mini rotary switches technical data general technical data standards iec/en 60 947, ul, csa control switches to iec/en 60 947-5-1 control circuit isolators to iec/en 60 947-5-1 control circuit isolators (iec/en 60 947-5-1) maximum 6 contacts; switching angle 90 lifespan, mechanical operations ops. > 1 x 10 6 max. operating frequency ops./h 3000 climatic proofing damp heat, constant, to iec 60 068 part 2-3 damp heat, cyclical, to iec 60 068 part 2-30 ambient temperature open min./max. c ? 25/+50 enclosed min./max. c ? 25/+40 mounting position as required mechanical shock resistance (shock duration 20 ms) g > 15 protection against direct contact finger and back-of-hand proof to iec 536 terminal capacity solid 1 conductor min./max. mm 2 0.75/1.5 2 conductors max. mm 2 1.5 (awg 14) flexible 1 conductor min. mm 2 0.75 (awg 18) 2 conductors max. mm 2 0.75 terminal screw m2.5 max. tightening torque nm 0.35 dimensions a page 07/108 contacts mechanical values contacts max. 16 contact units max. 8 switching angles 90/60/45/30 min. switching angle for on-off-on 60 switch positions max. 12 thickness of gold coating m m 35 electrical values rated operational voltage u e v ac 500 rated impulse withstand voltage u imp applicable to systems with earthed neutral point kv 4 overvoltage category/pollution degree iii/3 rated insulation voltage u i v ac 500 (ul/csa 300 v ac) rated uninterrupted current i u with max. cable connected a 10 switching capacity ac-23a motor load switches 220 ? 240 v, 3 h kw 1.8 380 ? 440 v, 3 h kw 3 500 v, 3 h kw 3.7 220 ? 240 v, 1 h kw 0.75 380 ? 440 v, 1 h kw 1.1 ac-15 control switches 220 ? 240 v, 1 h a 2.5 380 ? 415 v, 1 h a 1.5 440 v, 1 h a 1 dc-1 load-break switches 1 ? 24 v dc a 10 110 ? 240 v dc a 0.7 ? 0.3 dc-13 control switches l/r = 50 ms max. 32 v dc per contact a 3 switching capacity for north america 240 v, 3 h hp 1 277 v, 1 h hp o 300 v ac a 10 heavy duty short-circuit protective device maximum fuse a gg/gl 10 control circuit reliability 24 v dc, 10 ma fault probability h f < 10 ? 5 , < 1 fault in 100 000 operations moeller hpl0211-2001/2002 t0, t3 rotary switches dimensions rotary switches switch-disconnectors 07/096 flush mounting t0.../e (+ h3-t0) t3.../e (+ h3-t0) drilling dimensions centre mounting t0.../ez (/ofs) t3.../ez (/ofs) t0 t3 drilling dimensions t.../ez/ofs 48 48 zfs-...-t0 17 5 25 101 c20 35 h3-t0 75 90 10 C 11 3.1 C 3.5 12.2 30 48 48 17 1.5 ?5 c21 35 45 48 48 54 61 3.2 24.1 +0.4 0 22.3 +0.4 0 35 29 type c20 c21 t0-1... t0-2... t0-3... t0-4... t0-5... t0-6... t0-7... t0-8... t0-9... t0-10... t0-11... 41 50 60 69 79 88 98 107 117 126 136 61 70 80 89 99 108 118 127 137 146 156 depth of one contact unit: 9.5 mm type c20 c21 t3-1... t3-2... t3-3... t3-4... t3-5... t3-6... t3-7... t3-8... t3-9... t3-10... t3-11... 44 56 67 79 90 102 113 125 136 148 159 64 76 87 99 110 122 133 145 156 168 179 depth of one contact unit: 11.5 mm rotary switches switch-disconnectors 07/097 moeller hpl0211-2001/2002 t0, t3 rotary switches dimensions service distribution board mounting t0.../ivs drilling dimensions base t3.../xz + ivs-t0 drilling dimensions base rear mounting t0.../z t3.../z drilling dimensions base drilling dimensions door can be extended using zvv-t0, f 4 x 25 = 100 mm 54 55 45 m4 50 48 60 50 5 5 28 45 55 c22 5 63 65 45 54 m4 65 5 5 48 75 65 63 28 45 55 c22 5 5 48 48 17 zfs-...-t0 m4 50 5 C 5.5 36 36 5 C 5.5 36 36 m4 65 48 50 60 63 65 75 55 5 5 25 c23 c24 35 o 5 o o o 5 5 38, zav: 54 154 22.3 + 0.4 0 22.3 + 0.4 0 100 r a t3 t0 type c20 c21 c22 c23 c24 f / f c24 with f 4 zav c25 t0-1... t0-2... t0-3... t0-4... t0-5... t0-6... t0-7... t0-8... t0-9... t0-10... t0-11... 41 50 60 69 79 88 98 107 117 126 136 61 70 80 89 99 108 118 127 137 146 156 77 87 96 106 115 125 134 144 154 163 173 48 57 67 76 86 95 105 114 124 133 143 86 ? 102 96 ? 112 105 ? 121 115 ? 131 124 ? 140 134 ? 150 143 ? 159 153 ? 169 162 ? 178 172 ? 188 181 ? 197 202 212 221 231 240 250 259 269 278 288 297 72 72 91 91 ? ? ? ? ? ? ? depth of one contact unit: 9.5 mm type c20 c21 c22 c23 c24 f / f c24 with f 4 zav c25 t3-1... t3-2... t3-3... t3-4... t3-5... t3-6... t3-7... t3-8... t3-9... t3-10... t3-11... 44 56 67 79 90 102 113 125 136 148 159 64 76 87 99 110 122 133 145 156 168 179 80 92 103 115 126 138 149 161 172 184 195 51 63 74 86 97 109 120 132 143 155 166 86 ? 105 101 ? 115 112 ? 128 124 ? 139 135 ? 151 147 ? 162 158 ? 174 170 ? 185 181 ? 196 193 ? 208 204 ? 219 205 216 228 239 251 262 274 285 296 308 319 79 79 101 101 ? ? ? ? ? ? ? depth of one contact unit: 11.5 mm moeller hpl0211-2001/2002 t0, t3 rotary switches dimensions rotary switches switch-disconnectors 07/098 flush mounting main switches t0.../ea/svb t3.../ea/svb drilling dimensions door t0 t3 rear mounting main switches t0.../v/svb t3.../v/svb drilling dimensions base drilling dimensions door interlock can be extended using zvv-t0 + zav-t0, f 4 x 25 = 100 mm t0 t3 sheet steel enclosures t0-.../st, p1-.../st p3-.../st t3-.../st, t5(b)-.../st 65 33 17 48 on off off i o o 25 c20 35 5 zfs-...t0 61 54 49 45 3.1 C 3.5 30 10 C 11 12.2 i o o 65 33 17 48 zfs-...t0 5 5 25 c23 c24 35 38, 54 zvv+zav: 154 100 r on off off 65 75 63 5 5 m4 65 m4 50 50 60 49 5 22.3 + 0.4 0 5 C 5.5 36 36 m20 m4 174 m20 162 60 104 130 m4 184 m20 m25 m25 m20 184 140 184 140 m4 284 m25 m32 m25 184 193 140 140 rotary switches switch-disconnectors 07/099 moeller hpl0211-2001/2002 t0, t3 rotary switches dimensions surface mounting t0.../i1 drilling dimensions base t3.../i2 drilling dimensions base surface mounting main switches t0.../i1/svb drilling dimensions base t3.../i2/svb drilling dimensions base f 3 padlocks l-... 80 120 33.5 c25 27 137 m20 127 m4 l-... 100 160 35.5 c25 c33 180 m25 ? 8 171 m4 l-... 80 120 33.5 c25 35 m20 137 i off o on o off 127 m4 l-... 100 160 33.5 180 35 c25 m25 8 i off o on o off d b d = 4 C 8 mm b + d f 47 mm 171 m4 type c25 t0-1... t0-2... t0-3... t0-4... 75 75 95 95 type c25 c33 t3-1... t3-2... t3-3... t3-4... t3-5... 80 80 100 100 145 27 27 35 35 35 moeller hpl0211-2001/2002 t0, t3 rotary switches, accessories dimensions rotary switches switch-disconnectors 07/100 key operation s-t0 s-sond...-t0 t0.../e(i1) + s-(sond-)t0 t3.../e(i2) + s-(sond-)t0 t0.../z + s-(sond-)t0 t3.../z + s-(sond-)t0 t0.../ez t0../e + ez-t0 + s-(sond-)t0 t3.../ez t3../e + ez-t0 + s-(sond-)t0 cylinder lock sva-t3 t0.../i1/sva t3.../i2/sva t0.../e/sva... t3.../e/sva... t0.../z/sva... t3.../z/sva... push-button interlock padlocking feature dimensions as dtv-t3 dtv-t3 svc-t3 t0.../i1/dtv t3.../i2/dtv t0.../i1/svc t3.../i2/svc t0.../e/dtv... t3.../e/dtv... t0.../e/svc... t3.../e/svc... t0.../z/dtv... t3.../z/dtv... t0.../z/svc... t3.../z/svc... mounting clearance mounting clearances a and b: 4 mm exposed conductive part (metal) 17 27 48 48 zfs-...-t0 19 30 5 36 12.2 3.1 3.5 30 10...11 5 27 44 5 5.5 36 36 22.3 + 0.4 0 100 r 2 5 c20 22:25 28 30:23 26 3.2 30.5 17 3.2 12.5 22.3 + 0.4 0 73 48 zfs...-t0 56 73 46 30 56 73 46 30 56 73 46 30 73 48 zfs...-t0 56 73 46 48 56 73 46 48 56 73 46 48 b a a b rotary switches switch-disconnectors 07/101 moeller hpl0211-2001/2002 t5b, t5 rotary switches dimensions flush mounting t5(b).../e drilling dimensions door rear mounting t5(b).../z drilling dimensions base drilling dimensions door shaft can be extended using zav-p3, f 4 x 25 = 100 mm flush mounting main switches t5(b).../ea/svb drilling dimensions door rear mounting main switches t5(b).../v/svb drilling dimensions base drilling dimensions door can be extended using zvv-p3, f 4 x 25 = 100 mm 88 88 27 on off i o 18 c2 86 37 5 14 37 4.1 C 4.5 12 C 13 on off o i 88 88 27 48 5 C 5.5 48 30.5 c20 c2 37 25 25 5 38, 54 zav: 154 79 73 86 6.4 100 r a 88 27 88 on off off i o o 5 25 c2 88 80/90 40.5 16.5 44 100 80/90 14 37 4.1 C 4.5 12 C 13 on off off o i o 48 5 5.5 48 30.5 48 5 5.5 48 30.5 27 88 88 12 16.5 5 c20 5 25 25 40.5 44 100 80/90 73 85 100 r moeller hpl0211-2001/2002 t5b, t5 rotary switches dimensions rotary switches switch-disconnectors 07/102 surface mounting t5(b).../i4 t5.../i5 surface mounting main switches t5(b).../i4/svb drilling dimensions f 3 padlocks t5.../i5/svb drilling dimensions external fixing bracket 160 c22 37 m20 m25 m32 240 33.5 33.5 280 l-... 200 c22 37 l-... m20 m25 m50 l-... 160 240 33.5 c22 44 193 142 m5 i off o on o off d b d = 4 C 8 mm b + d f 47 mm 280 33.5 l-... 200 c22 44 233 182 m5 i off o on o off type c2 c20 f / f c24 with f 4 zav c21 c22 t5(b)-1... t5(b)-2... t5(b)-3... t5(b)-4... 54 71 87 104 92 ? 107 109 ? 124 125 ? 140 142 ? 157 207 224 240 257 90 90 123 123 125 (95) 125 (95) 160 (160) 160 (160) t5(b)-5... t5(b)-6... t5(b)-7... t5(b)-8... t5(b)-9... t5(b)-10... 120 137 153 170 186 203 158 ? 173 175 ? 190 191 ? 206 208 ? 223 224 ? 239 240 ? 356 273 290 306 323 339 356 ? ? ? ? ? ? ? ? ? ? ? ? depth of one contact unit: 16.5 mm the rotary switches t5b and t5 are of identical design but differ in their contacts 20 5.5 6.2 7.5 5 2.5 m5 ? 6 50 34 4.6 7.8 6 rotary switches switch-disconnectors 07/103 moeller hpl0211-2001/2002 t6, t8 rotary switches dimensions flush mounting t6.../e t8.../e flush mounting main switches t6-2/ea/svb rear mounting main switches t6-2/v/svb f 3 padlocks for t.../svb t6-160-6/v/svb-sw/hi11 t8-3-8342/v/svb-sw/hi11 drilling dimensions door t6: 4 m5 x 20 t8: 4 m6 x 20 150 58 5 c2 c30 b2 a2 88 88 90 125 zs 5.4 68 68 88 88 5 100 50 88 88 90 125 zs 5.4 68 68 88 88 4.5 5 110 50 40 100 300 r d b d = 4 C 8 mm b + d f 47 mm 9 88 73 5.5 1 93 216 200 5 76 224 6.4 h-t6-100 118 2 2 68 108 100 r 7 130 250 104 4.5 172.8 315 218 9.2 86.5 7 1 130 68 h-t8 19 100 r type a2 b2 c2 2 be 3 be c30 d1 d2 x1 y1 be = number of contact units t6... t8.../e t8.../svb 88 130 ? 88 130 ? 100 ? ? 152 173 ? 44 62 ? ? 26?30 ? 22?25 ? 38?42 ? 6.0 ? 7.0 ? 7.0 68 104 68 68 104 68 d2 d1 x1 y1 moeller hpl0211-2001/2002 p switch-disconnectors dimensions rotary switches switch-disconnectors 07/104 flush mounting p.../e centre mounting p1.../ez drilling dimensions door p1-.../e p1-.../ez p3-.../e service distribution board mounting p3.../ivs f 3 padlocks p1.../ivs rear mounting p.../z shaft can be extended using zav-..., f 4 x 25 = 100 mm drilling dimensions base p1.../z p3.../z drilling dimensions door on 0 i off a2 b2 b22 b3 a3 l3 l1 t3 t1 l2 t2 1 2 3 4 5 6 5 c2 c21 p1.../ez = c2 + 5 mm 4.1 ?4.5 3.2 22.3 +0.4 0 12.5 10 ?11 12.2 3.1 ?3.5 30 14 37 12 ?13 b3 a4 c22 c23 c3 5 45 n hi11 l3 l2 l1 t3 t2 t1 l3 l2 l1 t3 t2 t1 a32 a32 a31 d b d = 4 C 8 mm b + d f 47 mm 49 l1 l2 l3 t1 t2 t3 55 28 b3 45 5 c3 38 154 3 5 a3 5 b22 b2 a2 c21 c25 c20 r 100 c31 c32 b3 5 5.5 m4 65 36 36 22.3 +0.4 0 m4 75 25 5 C 5.5 48 48 30.5 type a2 a3 a4 a21 a22 a23 a31 a32 a33 b2 b3 b21 b22 b23 b24 b31 p1 p3 48 87 49 72 53.5 71.5 65 87 48 87 87 125 15 18 15 15 83 114 48 87 70 83 65 87 17 27 125 175 32 ? 49 60 type c2 c3 c20 f / f c20 with f 4 zav/zvv c21 c22 c23 c24 c25 c27 c28 c31 c32 c33 p1 p3 59 59 86 82 96 ? 112 103 ? 118 212 218 35 37 32 41 65 63 68 81 58 65 35 44 77 90 25 25 25 25 27 29 rotary switches switch-disconnectors 07/105 moeller hpl0211-2001/2002 p switch-disconnectors dimensions flush mounting main switches p.../ea/svb drilling dimensions door p1... p3... rear mounting main switches p.../v/svb interlock can be extended using zvv-t0 + zav-t0, f 4 x 25 = 100 mm drilling dimensions base p1.../v/svb p3.../v/svb drilling dimensions door surface mounting p1.../i2 surface mounting main switches / safety switches p1.../i2/svb p1.../i2/si drilling dimensions 5 b3 a3 on off b22 zfs-.... c27 c2 25 o o off i 1 2 3 4 5 6 n n y y a22 b21 a21 b31 h-p... 14 4.1 C 4.5 10 C 11 12.2 3.1 C 3.5 30 37 12 C 13 m mmmmmmm mmmmmmm mmmmm 5 5.5 m4 65 36 36 22.3 +0.4 0 m4 75 25 5 C 5.5 48 48 30.5 l-... a23 160 b24 c28 c33 m25 171 c27 m4 b23 m25 m25 8 moeller hpl0211-2001/2002 p switch-disconnectors dimensions rotary switches switch-disconnectors 07/106 surface mounting p3-63/i4 surface mounting main switches/safety switches p3-63/i4/svb p3-63/i4/si t5b-.../i4/si drilling dimensions surface mounting p3-100/i5 surface mounting main switches/safety switches p3-100/i5/svb p3-100/i5/si t5-.../i5/si drilling dimensions l-... a23 l pkz0 95 37 b23 b24 95 44 193 142 m5 m25 m32 m20 l-... a23 125 37 125 44 233 182 m5 l pkz0 m25 m50 m20 b23 b24 type a2 a3 a4 a21 a22 a23 a31 a32 a33 b2 b3 b21 b22 b23 b24 b31 p1.../i2 p3-63/i4 p3-100/i5 48 87 87 49 72 72 53.5 71.5 71.5 65 87 87 48 87 87 100 160 200 15 18 18 15 15 15 83 114 114 48 87 87 70 83 83 65 87 87 17 27 27 180 240 280 35.5 35.5 35.5 49 60 60 type c2 c3 c20 f / f c20 with f 4 zav/zvv c21 c22 c23 c24 c25 c27 c28 c31 c32 c33 p1... p3-63 p3-100 59 59 59 86 82 82 96 ? 112 103 ? 118 103 ? 118 212 218 218 35 37 37 32 41 41 65 63 63 68 81 81 58 65 65 35 44 44 80 125 125 25 25 25 25 25 25 27 37 37 rotary switches switch-disconnectors 07/107 moeller hpl0211-2001/2002 p switch-disconnectors, accessories dimensions cylinder lock sva-t3 p1.../i2/sva p1.../e/sva p1.../z/sva padlocking feature svc-t3 p1.../i2/svc p1.../e/svc p1.../z/svc modules switched neutral n-p... hi 11-p1/p3 auxiliary contacts f 3 padlocks 73 48 zfs...-t0 56 73 46 30 56 73 46 30 56 73 46 30 73 48 zfs...-t0 56 73 46 48 56 73 46 48 56 73 46 48 l3 l2 l1 t3 t2 t1 642 531 b31 a3 n-p h-p... hi 11 n n 13 246 a32 a31 a32 a32 a31 a32 a33 5 type a3 a31 a32 a33 b31 p1-... p3-.. 49 72 15 18 15 15 83 114 49 60 d b d = 4 C 8 mm b + d f 47 mm moeller hpl0211-2001/2002 tm mini rotary switches dimensions rotary switches switch-disconnectors 07/108 flush mounting tm.../e drilling dimensions control circuit isolators lockable using 2 padlocks ? 4 mm or 1 padlock ? 6mm tm-.../e/svb(-sw) drilling dimensions centre mounting tm-.../ez drilling dimensions 1) centre mounting with key operation tm-...+ez/s-.. drilling dimensions 1) service distribution board mounting tm-.../ivs notes 1) ) drilling dimension options: 16.2 mm = use without adapter rmq16; 22.3 mm = adapter required rmq-titan 28 c20 3 4.8 30 30 28 28 m3 m3 3.2 20 8 48 48 28 c21 3 35 38 38 m4 m4 10 4.2 30 f 5.5 28 30 17/19 1.7 17.9 3.2 24.1 +0.4 0 22.3 +0.4 0 16.2 +0.2 0 30 30 5.5 28 c20 35 12 17/19 1.7 17.9 3.2 24.1 +0.4 0 22.3 +0.4 0 16.2 +0.2 0 type c20 c21 tm-1... tm-2... tm-3... tm-4... tm-5... tm-6... tm-7... tm-8... 39 51 63 75 87 99 111 123 42 54 66 depth of one contact unit: 12 mm sh 35 60 45 auto hand o type s h tm-1... tm-2... 44 46 21 26.5 depth of one contact unit: 12 mm rotary switches switch-disconnectors 07/109 moeller hpl0211-2001/2002 p..., t5..., p7 safety switches engineering notes maintenance and safety switches have the same electrical function. they are designed to isolate electrical installations (loads) safely from the mains while maintenance work or repairs are being carried out, thereby ensuring that no hazard arises to personnel, machinery or product. the safety switch is an additional, enclosed main switch = isolator for an individual electrical load, and can be fitted directly next to the motor or the electrical load, ensuring that work on them can be carried out safely provided the 5 safety rules to vde 0105 are observed. this is of special importance if there is any possibility whatsoever of the main switch being wrongly identified. application by securing the switch in the off position with his own padlock (up to three can be fitted), the fitter/ electrician can protect himself against the possibility of any other person switching on the machine without authority. maintenance switches are merely additional, enclosed main switches with a padlocking facility. such switches can be found on pages 07/012? 015 or 07/024? 025 of this catalogue. features safety switches are housed in insulated enclosures as standard and bear the inscription ?safety switch? on a bright orange label. labels in other languages are available. switches to be used for emergency-stop switching have a special red handle and a yellow locking collar in accordance with stop category 0 to iec/en 60204. if the switch is not admissible for use as an emergency-stop switch, both parts are grey for p7 switch-disconnectors (type suffix ?-gr?) or black for t and p switches (type suffix ?-sw?). the cover and handle are interlocked when a padlock is in place. selection switches must be selected according to the following criteria: 1) the motor switching capacity, where the switch is fitted in such a way that the operator may use it for operational on and off switching. 2) the motor rating applies for 3 poles as standard. where the motor rating is divided between 6 poles, such as for a motor with star-delta starting, the 1.73 fold rating can be controlled with a 6-pole switch. 3) the uninterrupted current, where the switch has a load-shedding contact (la). the load-shedding contact is an auxiliary contact, which is closed in the on position and opens early when switching off, so that a contactor in the circuit takes over the switching capacity, and the maintenance/ safety switch operates at zero load. when switching on, the la closes later than or at the same time as the main contacts. with t and p switches, this is achieved by the auxiliary make contact, with p7... switches, it is achieved by series connection of the early-make auxiliary contact (vhi) and a standard auxiliary contact (nhi). 4) the uninterrupted current, provided that the switch is safely prevented from switching under load. 5) this can be achieved for example by padlocking the handle (which may need to be changed accordingly) in the on position. this is not admissible for switches with a red/yellow handle. old type/new type old type new type p3-63/i-si(-sw)(+hi..) p3-63/i4-si(-sw)(+hi..) p3-63/i-si(-sw)+n-p3 p3-63/i4-si(-sw)+n-p3 p3-63/i-si(-sw) +n+hi11 p3-63/i4-si(-sw) +n+hi11 t5b-3-8342/i-si(-sw) t5b-3-8342/i4-si(-sw) t5b-4-.../i-si(-sw) t5b-4-.../i4-si(-sw) p3-63/i-si(-sw)(+hi..) p3-63/i4-si(-sw)(+hi..) p3-63/i-si(-sw)+n-p3 p3-63/i4-si(-sw)+n-p3 t5-.../ci19/sih t5-.../i5-si t5-3-8342/ci19/sih t5-3-8342/i5-si t5-.../ci19/sih t5-.../i5-si technical data for p switch-disconnectors a page 07/092 technical data for t5(b) switch-disconnectors a page 07/090 dimensions for p a page 07/104 dimensions for t5(b) a page 07/101 p7 safety switches 63 a ? 250 a a page 10/016 safety switch with load shedding and indication indication load shedding on off k1m l2 n l3 l1 f1 k1m 2 1 4 3 6 5 f2 135 246 m 3 7911 81012 q1 uvw a2 k1m a1 a2 h1 h2 f0 faz- b4hi 95 96 21 22 f2 o 13 14 i 13 14 moeller hpl0211-2001/2002 t rotary switches, tm mini rotary switches ordering of non-standard contact sequences rotary switches switch-disconnectors 07/110 design notes for non-standard contact sequences key to type references t . . . . . . . . . . - . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . - . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ./ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .+ . . . . . . . . . . . . . . . . . . switch size number of contact units (2 contacts per contact unit) contact sequence number with manufacturing country identifier. for initial order enclose completed form (see next page). contact sequence number is issued by factory. for subsequent orders, type suffix is sufficient. mounting form ? mounting form /e centre mounting /ez (for t0, t3) surface mounting /i... 1) service distribution board mounting /ivs (for t0) rear mounting /z flush mounting main switches .../ea/ svb 2) surface mounting main switches /i.../ svb rear mounting main switches/v/svb 2) mounting forms for tm: /e, /ez or /ivs accessories a page 07/056 ? 071 state in full with every order! for tm.../ez only +ez/s... is possible a page 07/083 max. units max. contacts t0 11 22 t3 11 22 t5b 10 20 t5 10 20 tm 8 16 contact sequence the form fo 2 (see next page) makes it easy to determine the contact sequence. master copy a page 07/112 switching angles 30, 45, 60, 90 preferred angle: 60 for on/off switches: 90 for main switches: 90 as fs 908 page a 07/054 interruption of contact between 2 switch positions (on-off-on) not admissible on t0; or on t3 and tm at switching angles of 30, 45; or on t5(t5b) at a switching angle of 30 terminal markings tm switches have consecutive terminal markings, beginning with 1. spring-return the switching movement is limited by a stop. the switch returns under spring pressure to the last indexed position. where a switch has spring-return from both directions, a maximum of three positions can be traversed. the return angle is < m switching angle. a maximum of 6 contacts can be returned at the same time. fleeting contacts duration of contact depends primarily on the speed of actuation. if a contactor is to be actuated by means of fleeting contact, the switching angle of the rotary switch must not be less than 60, or the switching pulse may be too short. fleeting contacts always act in both directions. complete rotation possible only with a total switching angle of 360. unrestricted rotation in either direction. the number of switch positions multiplied by the switching angle must equal 360. tm with 12 positions every 30 is possible only with complete rotation, not with stop. number of contact units number of contacts = round up to nearest whole 2 each contact chamber = contact unit has 1 or 2 contacts, each operated by a cam. on t5(b) one cam operates both contacts. consequently: where the total switching angle is less than 180 , the contacts can be operated independently of one another. at switching angles of 180 and above, two contacts per chamber are possible only if their switching sequences are the same, but offset by 180 (e.g. t5b-4-8235 step switch). standard features as for rotary switches with standard contact sequences a page 07/006, 072 notes page technical data 07/090 dimensions 07/096 available mounting forms t0 07/084 t3 07/085 t5b 07/086 t5 07/087 tm 07/088 notes the sequence of the contacts may be changed if technical reasons so dictate. for non-standard switches it is preferable to arrange the links so that terminals whose numbers differ by 4 are linked with one another, e.g. terminals 1-5-9; 2-6- 10; 3-7-11- or 4-8-12-. such links can be removed (also applies for standard switches), whereas links 1-3, 2-4, 5-7, 6-8 cannot abe removed because they are situated within the switch. links between an even number and an odd number (e.g. 2-3) cannot be provided ex-factory, and must be supplied by the user. 1) t0-.../i1 up to 4 contact units t3-.../i2 up to 5 contact units 2) t0 up to 8 contacts = 4 contact units, t3 up to 12 contacts = 6 contact units rotary switches switch-disconnectors 07/111 moeller hpl0211-2001/2002 t rotary switches, tm mini rotary switches ordering of non-standard contact sequences erstbestellung fr nockenschalter t kombinationen initial order for a t rotary switch combination premire commande de combinaisons de commutateur t cames auftrags-nr.: order number: n de commande : position: item: poste : bro: office: bureau : bearbeiter: name: employ : kunde: customer: client: kundenspez.-nr.: customer number: n client : datum: date: date : hinweis: note: note : die anzahl der m?glichen kontakte sowie die kombinationsm?g- lichkeiten mit den baufor- men entnehmen sie bitte dem hauptkatalog. the number of possible contacts as well as possible combinations with mounting forms are shown in the main catalogue. reportez-vous au catalogue gnral pour conna?tre le nombre maximal de contacts et les possibilits de combinai- son selon les modles. stckzahl: quantity: quantit : schaltwinkel: switching angle: angle de rotation : type: type: rfrence : anzahl kontakte: no. of contacts: nombre de contacts : bauform: mounting form: modle : q 30 q tm q 1 q 12 q ? e q ? 45 q ? t0 q 2 q 13 q ea/svb q ea/svb-sw dm/stck: dm/each: prix unitaire : q 60 q t3 q 3 q 14 q ez q ez/ofs q 90 q t5b q 4 q 15 q i... q t5 q 5 q 16 q i.../svb q i.../svb-sw q 6 q 17 q ivs q 7 q 18 q v/svb q v/svb-sw q 8 q 19 q x q xz q ? 9 q 20 q z q 10 q 21 q ? + s-t0 q 11 q 22 q +___________________ frontschild nr. front plate no. plastron n fs _______________ baueinheiten /contact units/galettes 1234567891011 rundschaltung k complete rotation rotation totale autom. rckzug k ? spring-return retour autom. beschriftung marking/reprage grad degrees/degrs 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 270 1 ?????? ? 300 315 2 ??? ? 330 ? 03 ??? 30 45 4 ? 60 contact closed only in position 1 switching with interruption of contact switching without interrup- tion contact closed in positions 1 + 3 contact closed in positions 1 to 3 fleeting contact (only with 60 or 90) late-break contact early-make contact contact with automatic spring-return 90 120 135 150 key withdrawability with ..s-t0 or sva-t3: 180 pos. 1: key withdrawable with sva-t3, it is possible to switch between pos. 1 and 2 even after the key has been withdrawn. 210 pos. 2: key withdrawable 225 pos. 3: key withdrawable 240 pos. 4: key not withdrawable: schlssel abziehbar key withdrawable retrait de la cl x typ fr nachbestellungen (vom werk auszufllen) type for re-ordering (to be filled in by factory) rfrence pour commandes ultrieures ( complter par l?usine) t ___________________________________ 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 19 18 21 20 23 22 25 24 27 26 29 28 31 30 33 32 35 34 37 36 39 38 41 40 43 42 44 330 0 30 300 270 240 225 210 180 150 135 120 90 60 315 45 es ist m?glich, dass sich aus technischen grnden die reihenfolge der kontakte ?ndert. the sequence of contacts may be changed for technical reasons. l?ordre des contacts peut tre modifi pour des raisons techniques. max. characters per switching angle on fs plate degrees tm-e tm-ez tm-ivs t0(3) t5(b) 0.180 5 5 6 13 13 30, 210, 330 8 7 4 8 8 45, 135, 225, 315 6 5 4 6 7 60, 120, 240, 300 5 5 3 5 7 90, 270 5 4 1 4 7 150 4 4 4 8 8 moeller hpl0211-2001/2002 t rotary switches, tm mini rotary switches ordering of non-standard contact sequences rotary switches switch-disconnectors 07/112 erstbestellung fr nockenschalter t kombinationen initial order for a t rotary switch combination premire commande de combinaisons de commutateur t cames auftrags-nr.: order number: n de commande : position: item: poste : bro: office: bureau : bearbeiter: name: employ : kunde: customer: client: kundenspez.-nr.: customer number: n client : datum: date: date : hinweis: note: note : die anzahl der m?glichen kontakte sowie die kombinationsm?g- lichkeiten mit den baufor- men entnehmen sie bitte dem hauptkatalog. the number of possible contacts as well as possible combinations with mounting forms are shown in the main catalogue. reportez-vous au catalogue gnral pour conna?tre le nombre maximal de contacts et les possibilits de combinai- son selon les modles. stckzahl: quantity: quantit : schaltwinkel: switching angle: angle de rotation : type: type: rfrence : anzahl kontakte: no. of contacts: nombre de contacts : bauform: mounting form: modle : q 30 q tm q 1 q 12 q e q 45 q t0 q 2 q 13 q ea/svb q ea/svb-sw dm/stck: dm/each: prix unitaire : q 60 q t3 q 3 q 14 q ez q ez/ofs q 90 q t5b q 4 q 15 q i... q t5 q 5 q 16 q i.../svb q i.../svb-sw q 6 q 17 q ivs q 7 q 18 q v/svb q v/svb-sw q 8 q 19 q x q xz q 9 q 20 q z q 10 q 21 q +____________________ q 11 q 22 q +____________________ frontschild nr. front plate no. plastron n fs _______________ baueinheiten /contact units/galettes 1234567891011 rundschaltung k complete rotation rotation totale autom. rckzug k spring-return retour autom. beschriftung marking/reprage grad degrees/degrs 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 270 300 315 330 0 30 45 60 90 120 135 150 180 210 225 240 schlssel abziehbar key withdrawable retrait de la cl x typ fr nachbestellungen (vom werk auszufllen) type for re-ordering (to be filled in by factory) rfrence pour commandes ultrieures ( complter par l?usine) t __________________________ 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 19 18 21 20 23 22 25 24 27 26 29 28 31 30 33 32 35 34 37 36 39 38 41 40 43 42 44 330 0 30 300 270 240 225 210 180 150 135 120 90 60 315 45 es ist m?glich, dass sich aus technischen grnden die reihenfolge der kontakte ?ndert. the sequence of contacts may be changed for technical reasons. l?ordre des contacts peut tre modifi pour des raisons techniques. max. characters per switching angle on fs plate degrees tm-e tm-ez tm-ivs t0(3) t5(b) 0.180 5 5 6 13 13 30, 210, 330 8 7 4 8 8 45, 135, 225, 315 6 5 4 6 7 60, 120, 240, 300 5 5 3 5 7 90, 270 5 4 1 4 7 150 4 4 4 8 8 rotary switches switch-disconnectors 07/113 moeller hpl0211-2001/2002 t rotary switches, tm mini rotary switches ordering of non-standard front plates erstbestellung von sonderfrontschildern initial ordering of non-standard front plates premire commande de plastrons spciaux auftrags-nr.: order number: n de commande : position: item: poste : bro: office: bureau : bearbeiter: name: employ : kunde: customer: client: kundenspez.-nr.: customer number: n client : stckzahl: quantity: quantit : dm/stck: dm/each: prix unitaire : datum: date: date : non-standard front plates marking: front plate with black lettering insert text note the maximum number of characters allowed outside the marked areas! type q fs-sond-t0 (t3, p1) height of letters 2 characters 2 characters 4 mm 3 mm q fs-sond-p3 (t5b, t5) height of letters 2 characters 2 characters 8 mm 5 mm q q fs-sond-tm-e fs-sond-tm-ez height of letters 2 characters approx. 2 characters 3.5 mm 3 mm for p1 and p3 complete only the 270 and 0 positions max. number of characters possible item degrees tm-e tm-ez t0/p1 t5/p3 dimensions 0, 180 5 5 13 13 type size of front plate 30, 210, 330 8 7 8 8 45, 135, 225, 315 6 5 6 7 tm-.../e 29 x 29 mm (for frame sizes 30 x 30) 60, 120, 240, 300 5 5 5 7 tm-.../ez(-...) 29 x 29 mm (for frame sizes 30 x 30) 90, 270 5 4 4 7 t0, t3, p1 45 x 45 mm (for frame sizes 48 x 48) 150 4 4 8 8 p3, t5, t5b 84 x 84 mm (for frame sizes 88 x 88) typ fr nachbestellungen (vom werk auszufllen) type for re-ordering (to be filled in by factory) rfrence pour commandes ultrieures ( complter par lusine) fs ..................................................................................... |
Price & Availability of NP1E
![]() |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |