Part Number Hot Search : 
MTTAS T2810N FDP24N40 BAR18 S16A35 MM1099 10024 AT76C120
Product Description
Full Text Search
 

To Download DCU1-20-WR5 Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
  emi suppression.......................pi input filter, standard. reflected ripple current...........dcu1-5, 50 ma pp , max. dcu1-20, 75 ma pp , max. continuous output power.........see output voltage/current ratings. output voltage tolerance..........dcu1-5, 2%. dcu1-20wr/5, 2%. all other dcu1-20 models, 1%. external output trim .................dcu1-20-wr/5, +5%; other dcu1- 20 models, 5%. output noise and ripple...........dcu1-5, 75 mv pp , max. dcu1-20, 50 mv pp , max. (note 2). short-circuit protection.............dcu1-5, pulsed overload type. dcu1-20, cycle-by-cycle current limiting; internal thermal shutdown. over-voltage protection............130% of rated output voltage, typ. reverse voltage protection ......internal shunt diode. transient response ..................dcu1-5, 500 s recovery to within 1% of the regulation band after 25% step load change with no more than 200 mv deviation. dcu1-20, 200 s recovery to within 1% of the regulation band after 50% step load change with no more than 5% deviation. frequency of operation ............dcu1-5, 125 khz. dcu1-20, 72 khz. remote shutdown ....................dcu1-20, on = 0.5v to v in(max) or open circuit; off = 0.25v or less. standby mode current drain ....dcu1-20 series, less than 1.0 ma at v in = 24v. temperature range ..................-25? to +70?, no de-rating. temperature coefficient ............0.02%/? over the entire operating temperature range. relative humidity ......................0 to 95%, non-condensing. altitude ......................................0 to 10,000 feet. cooling ......................................convection cooling is adequate. moving air is recommended for operation in a confined area. storage temperature ................-40? to +100?. storage humidity ......................0 to 95%, non-condensing. mean time between failures ...dcu1-5, >250,000 hours. dcu1-20, >200,000 hours. (note 4.) 5w-20w ? wide input voltage ranges ? pi input filters?uilt-in emi suppression ? 20w model includes remote shutdown remote load sensing remote output voltage adjustment ? short-circuit/over-voltage protection ? compact packages ? six-sided shielding ? high efficiency ratings ? 2-year warranty ? 200,000-hour minimum mtbf c haracteristics input current max. input v oltage no full output output min. nom.max. load load voltage current line load effi- model (v) (v) (v) (a) (a) (v) (a) reg. reg. ciency dc-dc 5w single output dcu1-5-wr/5 7.0 12 32 0.025 0.600 5.10 1.0 0.5% 0.5% 74% dc-dc 20w single output dcu1-20-wr/5 8.0 24 36 0.015 1.020 5.05 4.0 0.5% 1.0% 82% notes 1. use of an external input line fuse is recommended: dcu1-5, use a 1.0a/125v slow-blow fuse. dcu1-20, use a 5a/125v slow-blow fuse. 2. peak-to-peak and rms metering equipment must have a 20 mhz frequency response with probes and cables that maintain a frequency response of 20 hz to 20 mhz. output ripple and spikes are measured directly at the output terminals of the converter with a 0.1 f ceramic capacitor. the probe ground band must make direct contact with the output return or the common terminal of the converter to prevent erroneous noise measurements. 3. all measurements are at nominal input, full load, and +25? unless other- wise specified. 4. mtbf is calculated using the parts stress method in mil-hdbk 217f (ground benign, t a = +25?). m odular dc-dc c onverters with n on -i solated i/o 152 will drive canton, ma 02021 usa phone 781-828-6216 fax 781-830-1155 email power@nidecpg.com http://www.nidec.com 43 power general
5w-20w a. dimensions shown are in inches. b. tolerances = 0.00 0.02 inch. 0.000 0.005 inch. c. module weight = 1.5 oz. (42.5g). dcu1-5 series a. dimensions shown are in inches. b. tolerances = 0.00 0.02 inch. 0.000 0.005 inch. c. module weight = 7.5 oz. (213g). dcu1-20 series pin-out pin dcu1-5 series dcu1-20 series 1+v in +v in 2-v in -v in 3+v out +sense 4 n/a output trim 5-v out - sense 6 n/a +v out 7 n/a - v out 8 n/a remote on/off output trim m odular dc-dc c onverters with n on -i solated i/o dcu 1 5 wr 5 series number of outputs output power (w) dc input voltage (wr = wide range) dc output voltage (v) - model selection guide / - 152 will drive canton, ma 02021 usa phone 781-828-6216 fax 781-830-1155 email power@nidecpg.com http://www.nidec.com 44 power general


▲Up To Search▲   

 
Price & Availability of DCU1-20-WR5

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X