  db15-000226-00 ITI3280UDCH-S compactpci dual channel ultra wide differential scsi host adapter user? guide october 2001 version 1.0
ii copyright 2001 by lsi logic corporation. all rights reserved. electromagnetic compatibility notices this equipment has been tested and found to comply with the limits for a class a digital device, pursuant to part 15 of the fcc rules. these limits are designed to provide reasonable protection against harmful interference in a commercial installation. this equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. operation of this equipment in a residential area is likely to cause harmful interference, in which case the user will be required to correct the interference at his own expense. lsi logic corporation is not responsible for any radio or television interference caused by unauthorized modi?ation of this equipment or the substitution or attachment of connecting cables and equipment other than those speci?d by lsi logic corporation. it is the users responsibility to correct interference caused by such unauthorized modi?ation, substitution, or attachment. this class a digital apparatus meets all requirements of the canadian interference-causing equipment regulations. cet appareil num?rique de la class? a respecte toutes les exigences du r?glement sure le mat?riel brouilleur du canada. lsi logic corporation north american headquarters milpitas, ca 408.433.8000
iii copyright 2001 by lsi logic corporation. all rights reserved. this document contains proprietary information of lsi logic corporation. the information contained herein is not to be used by or disclosed to third parties without the express written permission of an of?er of lsi logic corporation. lsi logic products are not intended for use in life-support appliances, devices, or systems. use of any lsi logic product in such applications without written consent of the appropriate lsi logic of?er is prohibited. document db15-000226-00, first edition (october 2001). this document describes the lsi logic ITI3280UDCH-S compactpci dual channel ultra wide differential scsi host adapter and will remain the of?ial reference source for all revisions/releases of this product until rescinded by an update. to receive product literature, visit us at http://www.lsilogic.com. lsi logic corporation reserves the right to make changes to any products herein at any time without notice. lsi logic does not assume any responsibility or liability arising out of the application or use of any product described herein, except as expressly agreed to in writing by lsi logic; nor does the purchase or use of a product from lsi logic convey a license under any patent rights, copyrights, trademark rights, or any other of the intellectual property rights of lsi logic or third parties. copyright 2001 by lsi logic corporation. all rights reserved. trademark acknowledgment the lsi logic logo design is a registered trademark of lsi logic corporation. solaris and the solaris logo are trademarks or registered trademarks of sun microsystems, inc. in the us and other countries and are used under license. all other brand and product names may be trademarks of their respective companies.
iv copyright 2001 by lsi logic corporation. all rights reserved.
ITI3280UDCH-S compactpci dual channel ultra wide differential scsi host adapter v copyright 2001 by lsi logic corporation. all rights reserved. preface this book is the users guide for the lsi logic ITI3280UDCH-S compactpci dual channel ultra wide differential scsi host adapter. it includes instructions for installing this adapter with regard to cold and hot installations and provides this adapters speci?ations. audience this document assumes that you have some familiarity with compactpci computers and related support devices. the people who bene? from this book are: ? engineers and managers who are evaluating or designing the host adapter board for possible use in a system ? end users who are installing the host adapter board into their computer organization this document has the following sections: ? section 1, ?eneral description ? section 2, ?perating environment ? section 3, ?reparing your system for adapter installation ? section 4, ?nstalling the ITI3280UDCH-S ? section 5, ?ttaching the ITI3280UDCH-S to the system ? section 6, ?xtracting the ITI3280UDCH-S ? section 7, ?sing the ITI3280UDCH-S
vi preface copyright 2001 by lsi logic corporation. all rights reserved. conventions used in this manual revision record notation example meaning and use courier typeface # cfagdm names of commands and the output from the commands are shown in courier type face and enclosed in a box. italic underscore attachment_point when an underscore appears in an italicized string next to a command, enter a user-supplied item of the type called for with no spaces. revision date remarks 1.0 10/01 first release.
ITI3280UDCH-S compactpci dual channel ultra wide differential scsi host adapter vii copyright 2001 by lsi logic corporation. all rights reserved. contents 1 general description 1-2 1.1 features 1-2 1.2 hardware and software requirements 1-2 1.3 scsi cable assemblies required 1-3 1.4 sun microsystems storage systems supported 1-3 2 operating environment 1-3 2.1 ITI3280UDCH-S speci?ations 1-4 2.2 physical characteristics 1-4 2.3 power requirements 1-4 2.4 board design 1-5 3 preparing your system for adapter installation 1-6 3.1 cold installation preparation 1-6 3.2 hot-swap installation preparation 1-6 4 installing the ITI3280UDCH-S 1-7 5 attaching the ITI3280UDCH-S to the system 1-8 5.1 cold environment attachment 1-8 5.2 hot-swap environment attachment 1-9 6 extracting the ITI3280UDCH-S 1-10 6.1 cold environment extraction 1-10 6.2 hot environment extraction 1-11 7 using the ITI3280UDCH-S 1-12 7.1 device driver software requirements 1-12 7.2 verifying the installation 1-12
viii contents copyright 2001 by lsi logic corporation. all rights reserved. figures 1 ITI3280UDCH-S compactpci host adapter 5 tables 1 hardware and software requirements 2 2 speci?ations 4 3 dimensions 4 4 power requirements 4
ITI3280UDCH-S compactpci dual channel ultra wide differential scsi host adapter 1 copyright 2001 by lsi logic corporation. all rights reserved. using the ITI3280UDCH-S compactpci adapter this document contains instructions and illustrations to help you install an lsi logic ITI3280UDCH-S compactpci dual channel ultra wide differential scsi host adapter into a compactpci computer system. this document provides the features, hardware and software requirements, and performance speci?ations for the ITI3280UDCH-S. instructions for inserting the ITI3280UDCH-S into your computer in both cold and hot installations and information about removing and reinstalling the ITI3280UDCH-S are also included. this information is located in these sections: ? section 1, ?eneral description, page 2 ? section 2, ?perating environment, page 3 ? section 3, ?reparing your system for adapter installation, page 6 ? section 4, ?nstalling the ITI3280UDCH-S, page 7 ? section 5, ?ttaching the ITI3280UDCH-S to the system, page 8 ? section 6, ?xtracting the ITI3280UDCH-S, page 10 ? section 7, ?sing the ITI3280UDCH-S, page 12
2 general description copyright 2001 by lsi logic corporation. all rights reserved. 1 general description the ITI3280UDCH-S is a compactpci dual ultra wide differential scsi host adapter. the following sections describe the features and requirements of the iti32080udch-s. 1.1 features the ITI3280UDCH-S supports these features: ? hot-swap compactpci installation and removal ? asynchronous and synchronous transfers ? wide and ultra scsi (40 mbytes/s ? ultra scsi narrow (20 mbytes/s) ? wide and fast scsi (20 mbytes/s) ? fast scsi narrow (10 mbytes/s) ? synchronous scsi data transfer rates (5 mbytes/s) ? high voltage differential (hvd) transceivers 1.2 hardware and software requirements before you use the iti32080udch-s, make sure your system meets the speci? hardware and software requirements as shown in ta b l e 1 . table 1 hardware and software requirements component requirements hardware any sun microsystems computer with an avail- able compactpci slot software the solaris 8 operating environment firmware openboot prom version 3.0. peripherals attached to pci adapter all scsi-2 high voltage differential devices
operating environment 3 copyright 2001 by lsi logic corporation. all rights reserved. 1.3 scsi cable assemblies required you will use one of two types of scsi cable assemblies based on your system. ? offset vhdci to offset vhdci or ? offset vhdci to hd68 each cable assembly must have a maximum cable length of 12 meters. 1.4 sun microsystems storage systems supported the ITI3280UDCH-S supports the following sun storage systems: ? sun storedge a1000 disk array ? sun storedge d1000 disk array ? sun storedge l9 tape library ? sun storedge l20 tape library ? sun storedge l180 tape library ? sun storedge l1000 tape library 2 operating environment this section presents the ITI3280UDCH-S speci?ations, physical characteristics, and power requirements.
4 operating environment copyright 2001 by lsi logic corporation. all rights reserved. 2.1 ITI3280UDCH-S speci?ations ta b l e 2 lists the performance speci?ations for the ITI3280UDCH-S. 2.2 physical characteristics ta b l e 3 provides the ITI3280UDCH-S dimensions. 2.3 power requirements ta b l e 4 provides the power requirements for the ITI3280UDCH-S. table 2 speci?ations feature speci?ation cpci clock 33 mhz max cpci data burst transfer rate 132 mbytes/s scsi synchronous transfer rate 40 mbytes/s scsi interface high voltage differential (hvd) scsi bus parity yes scsi 8-bit bus devices yes scsi 16-bit bus devices yes table 3 dimensions dimension measurement length 160 mm width 100 mm table 4 power requirements speci?ation measurement maximum power consumption 7.0 watts 5v (+5/-3%) supply current 0.65 a typical
operating environment 5 copyright 2001 by lsi logic corporation. all rights reserved. 2.4 board design figure 1 illustrates the ITI3280UDCH-S. figure 1 ITI3280UDCH-S compactpci host adapter port a led port a and port b external scsi connectors port b led hot-swap led red release button and ejection lever
6 preparing your system for adapter installation copyright 2001 by lsi logic corporation. all rights reserved. 3 preparing your system for adapter installation this section provides a general overview of the tasks needed to perform either a hot or cold installation. for the exact procedures required for your system, refer to the documentation that shipped with your system. 3.1 cold installation preparation before shutting down the operating environment and halting the system, ensure that all signi?ant application activity on the server has stopped. to prepare the system for a cold installation, follow these steps. step 1. follow the appropriate procedures, as documented in the systems service manual, to shut down and halt the system. step 2. refer to the systems documentation for the complete power down procedure and location of the power switch. step 3. press the power switch on the systems status panel to power down the system. step 4. verify that the systems power led is off, which indicates that the system is completely powered off. after the system has been shut down and powered off, you can safely install the card. 3.2 hot-swap installation preparation review your systems documentation for the complete hot-swap instructions before performing these steps. step 1. type the following command: step 2. con?m that the intended slot can be identi?d as uncon?ured on the list that appears after issuing this command. # cfgadm
installing the ITI3280UDCH-S 7 copyright 2001 by lsi logic corporation. all rights reserved. 4 installing the ITI3280UDCH-S to install the ITI3280UDCH-S into your system, follow these steps: step 1. identify the slot number where you want to insert the adapter. step 2. refer to the systems documentation for instructions on how to remove the ?ler panel. step 3. remove the ?ler panel from the slot you selected. step 4. push on the red release button and open the ITI3280UDCH-S cards ejection lever before installing the card in the system. step 5. pull back the ejection lever and slide the card into the compactpci slot. step 6. apply even pressure at both corners of the card and push the card until it is ?mly seated in the slot. step 7. push the ejection lever over the sprocket toward the card and into the locked position. this locks the card into the slot. step 8. use a phillips screwdriver to tighten the captive screws inside the cards ejection lever. note: in a hot-swap installation, the solaris operating system automatically con?ures the storage devices. step 9. attach the scsi cable to either port a or port b of the ITI3280UDCH-S. this completes the hardware installation. impor tant: check your systems documentation for any additional actions that may be required to con?ure the system software for the newly inserted card. for example, in some systems you must type the following command: this command turns off the blue led and initiates the software, which responds by con?uring the system software for the newly inserted card. # cfgadm -c configure attachment_point
8 attaching the ITI3280UDCH-S to the system copyright 2001 by lsi logic corporation. all rights reserved. 5 attaching the ITI3280UDCH-S to the system after you install your ITI3280UDCH-S, you must make the system recognize the new adapter. the correct attachment of your adapter into your system depends upon whether you installed the adapter in a cold or hot-swap environment. 5.1 cold environment attachment before powering on the system, make sure that you have connected all the cables and have powered on all the peripheral devices. to power on the system after a cold installation, follow the appropriate procedures as documented in your systems hardware installation manual. after powering on the system, follow these steps. step 1. check the hot-swap led on the adapter. if the blue led is off, you have installed the adapter correctly. at this point, you have veri?d the installation. or if the hot-swap led remains on, you did not install the adapter correctly. at this point, follow the instructions in the remaining steps. step 2. remove and reinstall the adapter to make sure it is seated correctly in the slot. see section 4, ?nstalling the ITI3280UDCH-S, page 7 for the installation instructions. if you have to reinstall the card, you must also follow the instructions outlined in your systems service manual for the removal and replacement of i/o adapter cards. also refer to the troubleshooting section of your systems documentation for additional reinstallation instructions. step 3. verify that the systems power led is on, which indicates that the system has completely powered on.
attaching the ITI3280UDCH-S to the system 9 copyright 2001 by lsi logic corporation. all rights reserved. 5.2 hot-swap environment attachment to attach your ITI3280UDCH-S in a hot-swap environment, follow the hot-swap procedures for i/o card attachments in your systems server or hardware installation manual. the system software should automatically recon?ure the newly swapped card. to activate the ITI3280UDCH-S, follow these steps: step 1. type this command at the system console: where ap_id represents the attachment point id. step 2. verify the con?ured status of the appropriate slots. step 3. check the hot-swap led on the adapter. if the blue led is off, you have installed the adapter correctly. at this point, you have veri?d the installation. or if the hot-swap led remains on, you did not install the adapter correctly. at this point, follow the instructions in the remaining steps. step 4. remove and reinstall the ITI3280UDCH-S to make sure it is seated correctly in the slot. see section 4, ?nstalling the ITI3280UDCH-S, page 7 for the installation instructions. if you have to reinstall the card, you must also follow the instructions outlined in your systems service manual for the removal and replacement of i/o cards. refer to the troubleshooting section of your systems documentation for additional reinstallation instructions. # cfgadm -c connect ap_id
10 extracting the ITI3280UDCH-S copyright 2001 by lsi logic corporation. all rights reserved. 6 extracting the ITI3280UDCH-S the ITI3280UDCH-S is a component that you can extract from a hot- swap-compliant system without interrupting the operation of the system. you can also extract the adapter if you installed it in a cold environment after you power down the system. you must determine whether you want to perform a cold extraction of the adapter or a hot extraction. in a cold extraction, you must shut down the systems operating system and power down the system before extracting the adapter. in a hot-swap extraction, you may be required to enter software commands before and after the extraction to detach the adapter from the system correctly. note : the following procedures provide a general overview of the tasks needed to prepare for either a hot or cold extraction. for the speci? procedures required for your system, refer to the documentation that shipped with your system. 6.1 cold environment extraction before extracting your adapter, ensure that all signi?ant application activity on the server has stopped. to extract the ITI3280UDCH-S, follow these steps. step 1. refer to the systems documentation for the complete power down procedure and location of the power switch. step 2. press the power switch on the systems status panel to power down the system. step 3. verify that the systems power led is off, which indicates that the system is completely powered off. step 4. extract the ITI3280UDCH-S after the system has been shut down and powered off.
extracting the ITI3280UDCH-S 11 copyright 2001 by lsi logic corporation. all rights reserved. 6.2 hot environment extraction to extract the adapter from a hot environment, follow these steps. step 1. as superuser, identify the cpci card to be removed. you must know the slot number (attachment point id). to identify the slot number, type: note: i/o assemblies are indicated by "..sg--..". the attachment points (board slots) displayed are numbered staring with 0 at the system board side of the cpci i/o assembly. in the example above, the ITI3280UDCH-S is indicated by asterisks ( *** ). step 2. type this command to detach (uncon?ure) the ITI3280UDCH-S: where attachment_point is pcisc hxxx , for example, in the example used in step 1, pcisch10 is the attachment point for the ITI3280UDCH-S. the following example is based on information from step 1. step 3. type this command to con?m the board detachment: # cfgadm pci ap_id type receptacle occupant condition pcisch10:sg8slot3*** mult/fhs connected configured ok pcisch11:sg8slot1 unknown empty unconfigured unknown pcisch8:sg8slot2 stpcipci/fhs connected configured ok # cfgadm -c unconfigure attachment_point # cfgadm -c unconfigure attachment_point sep 14 12:22:00 r84 sghsc: sghsc_control: board 8, slot 3 unconfigured. # cfgadm pci ap_id type receptacle occupant condition pcisch10:sg8slot3*** unknown disconnected unconfigured unknown pcisch11:sg8slot1 unknown empty unconfigured unknown pcisch8:sg8slot2 stpcipci/fhs connected configured ok
12 using the ITI3280UDCH-S copyright 2001 by lsi logic corporation. all rights reserved. step 4. check that the blue led is on. step 5. push on the red release button and pull back on the adapter cards ejection lever. step 6. slide the card out of the compactpci slot. 7 using the ITI3280UDCH-S this section provides driver requirements and methods to verify the proper installation of the ITI3280UDCH-S. 7.1 device driver software requirements to support the device drivers for the ITI3280UDCH-S, you must have the solaris 8 4/01 operating environment installed in your system. after they are installed, the boards have device paths similar to this example: /ssm@0,0/pci@18,700000/pci@2/scsi@5 (scsi) under these nodes, one instance of the device driver that has device nodes is evident: /ssm@0,0/pci@18,700000/pci@2/scsi@5/st (byte) /ssm@0,0/pci@18,700000/pci@2/scsi@5/sd (block) 7.2 verifying the installation to verify the proper installation of the ITI3280UDCH-S before booting the operating system, follow one of these two methods.
using the ITI3280UDCH-S 13 copyright 2001 by lsi logic corporation. all rights reserved. 7.2.1 method 1 using the show-devs command step 1. access the ok prompt. type the show-devs command: step 2. the system would display output similar to this: device paths with scsi@5 indicate the use of ITI3280UDCH-S port a. device paths with scsi@5,1 indicate the use of ITI3280UDCH-S port b. ok show-devs / (gptwo) /ssm@0, 0 (gptwo /ssm@0, 0/pci@19,600000 (pci) /ssm@0, 0/pci@19,600000/pci@1 (pci) /ssm@0, 0/pci@19,600000/pci@1/sunw,qlc@5 (scsi-fcp) /ssm@0, 0/pci@19,600000/pci@1/sunw,qlc@5/fp@0,0 (fp) /ssm@0, 0/pci@19,600000/pci@1/sunw,qlc@5/fp@0,0/disk (block) /ssm@0, 0/pci@19,600000/pci@1/sunw,qlc@4 (scsi-fcp) /ssm@0, 0/pci@19,600000/pci@1/sunw,qlc@4/fp@0,0 (fp) /ssm@0, 0/pci@19,600000/pci@1/sunw,qlc@4/fp@0,0/disk (block) /ssm@0, 0/pci@19,700000 (pci) /ssm@0, 0/sghsc@18,700000 (sghsc) /ssm@0, 0/pci@18,600000 (pci) /ssm@0, 0/pci@18,600000/pci@1/sunw,isptwo@4 (scsi) /ssm@0, 0/pci@18,600000/pci@1/sunw,isptwo@4/st (byte) /ssm@0, 0/pci@18,600000/pci@1/sunw,isptwo@4/sd (block) /ssm@0, 0/pci@18,600000/pci@1/sunw,hme0,1 (network) /ssm@0, 0/pci@18,600000/pci@1/pci08e.1000@0 /ssm@0, 0/pci@18,700000 (pci) /ssm@0, 0/pci@18,700000/pci@2 (pci) /ssm@0, 0/pci@18,700000/pci@2/scsi@5 (scsi) 1 /ssm@0, 0/pci@18,700000/pci@2/scsi@5/st (byte) /ssm@0, 0/pci@18,700000/pci@2/scsi@5/sd (block) /ssm@0, 0/pci@18,700000/pci@2/scsi@5,1 (scsi) 2 /ssm@0, 0/pci@18 700000/pci@2/scsi@5,1/st (byte) /ssm@0, 0/pci@18,700000/pci@2/scsi@5,1/sd (block) /ssm@0, 0/pci@18,700000/bootbus-controller@4 /ssm@0, 0/memory-controller@3,400000 (memory-controller)
14 using the ITI3280UDCH-S copyright 2001 by lsi logic corporation. all rights reserved. 7.2.2 method 2 - using the probe-scsi-all command step 1. access the ok prompt. type the probe-scsi-all command: step 2. the system then displays output similar to this: in this example, the ?st scsi port ( scsi@2 ) has one disk drive connected (target 8). the second scsi port ( scsi@2,1 ) also has one disk drive connected (target 1). ok probe-scsi-all /pci@1f,2000/scsi@2 target 8 unit 0 disk seagate st34371w sun4.2g8254 /pci@1f,2000/scsi@2,1 target 1 unit 0 disk seagate st34371w sun4.2g8254
ITI3280UDCH-S compactpci dual channel ultra wide differential scsi host adapter customer feedback we would appreciate your feedback on this document. please copy the following page, add your comments, and fax it to us at the number shown. if appropriate, please also fax copies of any marked-up pages from this document. impor tant: please include your name, phone number, fax number, and company address so that we may contact you directly for clari?ation or additional information. thank you for your help in improving the quality of our documents.
readers comments fax your comments to: lsi logic corporation technical publications m/s e-198 fax: 408.433.4333 please tell us how you rate this document: ITI3280UDCH-S compactpci dual channel ultra wide differential scsi host adapter users guide . place a check mark in the appropriate blank for each category. what could we do to improve this document? if you found errors in this document, please specify the error and page number. if appropriate, please fax a marked-up copy of the page(s). please complete the information below so that we may contact you directly for clari?ation or additional information. excellent good average fair poor completeness of information ____ ____ ____ ____ ____ clarity of information ____ ____ ____ ____ ____ ease of ?ding information ____ ____ ____ ____ ____ technical content ____ ____ ____ ____ ____ usefulness of examples and illustrations ____ ____ ____ ____ ____ overall manual ____ ____ ____ ____ ____ name date telephone title company name street city, state, zip department mail stop fax
you can ?d a current list of our u.s. distributors, international distributors, and sales of?es and design resource centers on our web site at http://www.lsilogic.com/contacts/na_salesof?es.html


▲Up To Search▲   

 
Price & Availability of ITI3280UDCH-S

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X