![]() |
|
If you can't view the Datasheet, Please click here to try to view without PDF Reader . |
|
Datasheet File OCR Text: |
http://www.tracopower.com features ultra compact, low profile plastic case single-, dual- and triple output models 2 p ackage v ersions: - screw terminal block for chassis mount - solder pins for direct pcb mount din-rail mount adaptor (optional) universal input 85-264 vac, 47-440 hz protection class ll iec/en/ul 60950-1 approval, cb-report short circuit and overload protection 3-year product warranty the tmp series ac/dc power modules is a new range of fully encapsulated power supplies in an ultra-compact module. they feature easy chassis mounting with screw terminal block connection or direct pcb mounting with solder pins. full compliance with international safety standards for industrial control equipment qualifes the products for worldwide markets. these power supplies offer a cost effective solution for many space critical applica - tions in commercial and industrial electronic equipment. order code output power output pcb-mount chassis mount max. with solder pins with screw terminal block tmp 07103 4.6 w 3.3 vdc / 1400 ma tmp 07105 5.0 vdc / 1400 ma tmp 07112 7 w 12 vdc / 585 ma tmp 07115 15 vdc / 465 ma tmp 07124 24 vdc / 290 ma tmp 10103 6.6 w 3.3 vdc / 2000 ma tmp 10105 5.0 vdc / 2000 ma tmp 10112 10 w 12 vdc / 830 ma tmp 10115 15 vdc / 665 ma tmp 10124 24 vdc / 415 ma tmp 15105 tmp 15105c 5 vdc / 3000 ma tmp 15112 tmp 15112c 12 vdc / 1250 ma tmp 15115 tmp 15115c 15 w 15 vdc / 1000 ma tmp 15124 tmp 15124c 24 vdc / 625 ma tmp 15148 tmp 15148c 48 vdc / 310 ma single output models 7 to 15 watt ac/dc power modules tmp series, 7 to 60 watt page 1 of 11 cb scheme ul 60 95 0- 1 30 & 60 watt and multi output models see next page -->
http://www.tracopower.com ac/dc power modules tmp series 7 to 60 watt all specifcations valid at nominal input voltage, full load and +25c after warm-up time unless otherwise stated. page 2 of 11 order code output output 1 output 2 output 3 pcb-mount chassis mount with power with solder pins screw terminal block max. tmp 10212 10 watt +12 vdc/380 ma C12 vdc/380 ma tmp 10215 +15 vdc/300 ma C15 vdc/300 ma tmp 15212 tmp 15212c +12 vdc/650 ma C12 vdc/650 ma tmp 15215 tmp 15215c +15 vdc/500 ma C15 vdc/500 ma tmp 15252 tmp 15252c 15 watt 5.0 vdc/1500 ma 12 vdc/625 ma tmp 15512 tmp 15512c 5.0 vdc/2000 ma +12 vdc/200 ma C12 vdc/200 ma tmp 15515 tmp 15515c 5.0 vdc/2000 ma +15 vdc/150 ma C15 vdc/150 ma tmp 30212 tmp 30212c +12 vdc/1300 ma C12 vdc/1300 ma tmp 30215 tmp 30215c +15 vdc/1000 ma C15 vdc/1000 ma tmp 30252 tmp 30252c 5.0 vdc/3000 ma 1) 12 vdc/1250 ma 4) tmp 30512 tmp 30512c 30 watt 5.0 vdc/3000 ma 1) +12 vdc/600 ma 5) C12 vdc/600 ma 5) tmp 30515 tmp 30515c 5.0 vdc/3000 ma 1) +15 vdc/500 ma 6) C15 vdc/500 ma 6) tmp 30522 tmp 30522c 5.0 vdc/3000 ma 1) +12 vdc/1000 ma 7) C12 vdc/250 ma 9) tmp 30316 tmp 30316c 3.3 vdc/4000 ma 2) +5.0 vdc/1500 ma 8) +12 vdc/250 ma 9) tmp 30317 tmp 30317c 5.0 vdc/4500 ma 3) +3.3 vdc/1000 ma 7) +12 vdc/250 ma 9) dual- and triple output models peak current: 1) 4500 ma 2) 5300 ma 3) 6000 ma 4) 1800 ma 5) 900 ma 6) 750 ma 7) 1500 ma 8) 2000 ma 9) 500 ma total load not to exceed 30 watt. order code output power output pcb-mount chassis mount max. with solder pins with screw terminal block tmp 30105 tmp 30105c 5 vdc / 6000 ma tmp 30112 tmp 30112c 12 vdc / 2500 ma tmp 30115 tmp 30115c 30 w 15 vdc / 2000 ma tmp 30124 tmp 30124c 24 vdc / 1250 ma tmp 30148 tmp 30148c 48 vdc / 625 ma tmp 60105 tmp 60105c 51 w 5.1 vdc / 10000 ma tmp 60112 tmp 60112c 12 vdc / 5000 ma tmp 60115 tmp 60115c 15 vdc / 4000 ma tmp 60124 tmp 60124c 60 w 24 vdc / 2500 ma tmp 60136 tmp 60136c 36 vdc / 1665 ma tmp 60148 tmp 60148c 48 vdc / 1250 ma single output models 30 to 60 watt input specifications input voltage C nominal 100 C 240 vac C range 85 C 264 vac (universal input) 120 C 370 vdc (not for tmp 60 models) input frequency 47 C 400 hz 47 C 63 hz for tmp 60 models http://www.tracopower.com ac/dc power modules tmp series 7 to 60 watt page 3 of 11 all specifcations valid at nominal input voltage, full load and +25c after warm-up time unless otherwise stated. input specifications input current at full load (115 vac / 230 vac) 7 w models: 150 ma / 100 ma typ. 10 w models: 200 ma / 130 ma typ. 15 w models: 300 ma / 190 ma typ. 30 w models: 550 ma / 330 ma typ. 60 w models: 1050 ma / 670 ma typ. input current at no load (115 vac / 230 vac) 15 ma / 20 ma typ. inrush current (< 2ms, cold start at 115 vac / 230 vac) 7 C 10 w models: 10 a / 20 a 15 w models: 15 a / 30 a 30 w models: 20 a / 40 a 60 w models: 30 a / 50 a external input fuse required (recommended value) 7 C 30 w models: 1.5 a slow blow other models: 3.0 a slow blow output specifications voltage set accuracy 2 % max. regulation C input variation 1 % max. C load variation single output models (10C100%): 1 % max. dual output models balanced load (10C100%): 2.5 % max. dual output models unbalanced load (20/100%): 5.0 % max. triple output models main output (10C100%): 1.0 % max. triple output models auxiliary outputs (10C100%): 4.0 % max. minimum load single an dual output models: 10 % of rated max. current triple output models main output: 10 % of rated max. current triple output models auxiliary outputs: 20 % of rated max. current operation at lower load condition will not damage these power supplies, how ever, they may not meet all listed specifications. max. capacitive load [f] model series output: tmp 07 tmp 10 tmp 15 tmp 30 tmp 60 single output models: 3.3 vdc 2200 3900 - - - 5.0 / 5.1 vdc 2200 3300 3900 8000 8000 12 / 15 vdc 1000 2200 2200 3900 3900 24 vdc 680 1000 1000 1500 1500 36 vdc - - - - 1000 48 vdc - - 680 1000 800 dual output models: 5 vdc - - 2000 3900 - +12 / C12 / +15 / C15 vdc - 1000 1500 1500 - t riple output models: 3.3 / 5.0 vdc - - 2200 2200 - +12 / C12 / +15 / C15 vdc - - 1500 1500 - ripple and noise (20mhz bandwidth) 3.3 vdc & 5.0 vdc outputs: 1.8% of vout [mvpk-pk] other outputs: 1.3% of vout [mvpk-pk] overload protection by current limit 120% C 180% of inom, fold back, automatic recovery (long term overload condition may cause damage to the power supply) overvoltage protection by zehner diode (main output only) 120% of vout typ. rise time 200 ms typ. hold-up time 20 ms typ. general specifications http://www.tracopower.com page 4 of 11 ac/dc power modules tmp series 7 to 60 watt general specifications temperature ranges C operating C25c to +70c C storage (non-operating) C40c to +85c power derating 3.75 %/k above +50c 2.5 %/k above +40c for tmp 60105(c) temperature coefficient 0.02 %/k humidity (non-condensing) 95 % rel. h max. efficiency 78 % typ. switching frequency 100 khz typ. (fixed) isolation v oltage (60 sec.) C input/output 3000 vac isolation resistance C input/output 100 mohm (at 500 vdc) electromagnetic compatibility (emc), emissions en 61000-6-3: 2007 en 61204-3: 2000, class a en 55022, level b, fcc part 15 level b electromagnetic compatibility (emc), immunity en 61000-6-2: 2005 en 61204-3: 2000, class a C electrostatic discharge esd en 61000-4-2 8 kv / 4 kv, criteria b C rf field susceptibility en 61000-4-3 10 v/m, criteria a C electrical fast transient / burst immunity input en 61000-4-4 2 kv, criteria b C electrical fast transient / burst immunity output en 61000-4-4 2 kv, criteria b C surge immunity line C neutral en 61000-4-5, 1 kv, criteria b C surge immunity output en 61000-4-5 0.5 kv, criteria b C immunity to conducted rf disturbances en 61000-4-6 10 v, criteria b C mains voltage dips and interruptions en 61000-4-11 30 % 10 ms, criteria b 60 % 100 ms, criteria c 95 % 5000 ms, criteria c emc test certificates www.tracopower.com/products/tmp-em c .pdf protection class ii to iec/en 60536 safety standards C information technology equipment iec/en 60950-1, ul 60950-1 safety approvals C cb certificate for iec 60950-1 www.tracopower.com/products/tmp-cb.pd f (tmp 60 models pending) C ul approvals for ul 60950-1 www.ul.com -> certifications -> file: e188913 reliability /calculated mtbf tmp 07 models: >330000 h (mil-hdbk-217f, at 25 c, ground benign) tmp 10 models: >300000 h tmp 15 models: >280000 h tmp 30 models: >250000 h tmp 60 models: >125000 h case material plastic resin + fiberglass ( ul 94v-0 rated ) all specifcations valid at nominal input voltage, full load and +25c after warm-up time unless otherwise stated. http://www.tracopower.com page 5 of 11 ac/dc power modules tmp series 7 to 60 watt outline dimensions pin diameter: 1.0 (0.04) tmp 07 models for pcb mount: tmp 10 models for pcb mount: weight: 44 g (1.55 oz) dimensions in [mm], ( ) = inches case tolerances: 0.5 (0.02) pin pich tolerance: 0.25 (0.01) 19.3 0.5 6.0 5.0 (0.02) (0.24) (0.76) (0.20) 5.0 (0.20) 1 2 4 3 10.16 25.4 20.32 2.54 45.72 50.80 (0.40) (1.00) (0.80) (0.10) bottom view (1.80) (2.00) 2.54 (0.10) pin single 1 ac (n) 2 ac (l) 3 +vout 4 Cvout pin-out 1 2 4 3 5 10.16 10.16 45.0 17.78 19.0 0.5 6.0 54.0 64.0 5.0 (0.40) (0.40) (1.77) (0.70) (0.02) (0.24) (0.75) (0.20) 5.0 (0.20) bottom view (2.13) (2.52) 4.0 (0.16) 22.5 (0.89) pin single dual 1 ac (n) ac (n) 2 ac (l) ac (l) 3 Cvout vout 2 4 ntc com.1/2 5 +vout vout 1 pin-out pin diameter: 1.0 (0.04) weight: 92 g (3.25 oz) (ntc = not to connect) http://www.tracopower.com page 6 of 11 ac/dc power modules tmp series 7 to 60 watt outline dimensions tmp 15 models for pcb mount: tmp 15 models for chassis mount: dimensions in [mm], ( ) = inches case tolerances: 0.5 (0.02) pin pich tolerance: 0.25 (0.01) mounting hole tolerance: 0.25 (0.02) 1 2 5 4 6 11.43 54.0 20.32 62.0 74.0 (0.45) (2.13) (0.80) bottom view (2.44) (2.91) 3 8.89 (0.35) 7 27.0 (1.06) 11.43 (0.45) 8.89 (0.35) 2 x m3.5 thd 19.9 (0.78) 19.9 (0.78) 40.0 (1.57) 6.0 (0.24) 19.3 0.5 6.0 5.0 (0.02) (0.24) (0.76) (0.20) 5.0 (0.20) pin single dual sym. dual asym. triple 1 ac (n) 2 ac (l) 3 no pin vout 3 4 Cvout vout 2 Cvout 2 com.2/3 5 no pin com.1/2 +vout 2 vout 2 6 +vout vout 1 Cvout 1 Cvout 1 7 no pin +vout 1 +vout 1 pin-out 5 46 37 1 2 t op view 86.0 96.0 (3.39) (3.78) 5.0 (0.20) 54.0 (2.13) 4.0 (0.16) 46.0 (1.81) 76.0 (2.99) 10.0 (0.39) 23.3 (0.92) 5.0 (0.20 11.8 (0.46) 4 x ?3.5 pin single dual sym. dual asym. triple 1 ac (n) 2 ac (l) 3 not to connect vout 3 4 Cvout vout 2 Cvout 2 com.2/3 5 ntc com.1/2 +vout 2 vout 2 6 +vout vout 1 Cvout 1 Cvout 1 7 not to connect +vout 1 +vout 1 connection (ntc = not to connect) pin diameter: 1.0 (0.04) weight: 114 g (4.02 oz) weight: 162 g (5.71 oz) http://www.tracopower.com page 7 of 11 ac/dc power modules tmp series 7 to 60 watt outline dimensions tmp 30 models for pcb mount: 1 2 5 4 6 63.5 31.75 81.3 88.9 (2.50) (1.25) bottom view (3.20) (3.50) 3 7 27.94 (1.10) 12.70 (0.50) 15.24 (0.60) 2 x m3.5 thd 27.5 (1.08) 3.8 (0.15) 5.0 (0.20) 27.65 (1.09) 12.70 (0.50) 15.24 (0.60) 27.94 (1.10) 21.5 0.5 6.0 5.0 (0.02) (0.24) (0.85) (0.20) 5.0 (0.20) pin single dual sym. dual asym. triple 1 ac (n) 2 ac (l) 3 +vout vout 1 +vout 2 vout 2 4 no pin +vout 1 +vout 1 5 Cvout com.1/2 Cvout 2 com 2/3 6 no pin Cvout 1 Cvout 1 7 ntc vout 2 ntc vout 3 pin-out (ntc = not to connect) dimensions in [mm], ( ) = inches case tolerances: 0.5 (0.02) pin pich tolerance: 0.25 (0.01) mounting hole tolerance: 0.25 (0.02) pin diameter: 1.0 (0.04) weight: 177 g (6.24 oz) http://www.tracopower.com page 8 of 11 ac/dc power modules tmp series 7 to 60 watt outline dimensions tmp 30 models for chassis mount: pin single dual sym. dual asym. triple 1 ac (n) 2 ac (l) 3 +vout vout 1 +vout 2 vout 2 4 not to connect +vout 1 +vout 1 5 Cvout com.1/2 Cvout 2 com 2/3 6 not to connect Cvout 1 Cvout 1 7 ntc vout 2 ntc vout 3 connection (ntc = not to connect) dimensions in [mm], ( ) = inches case tolerances: 0.5 (0.02) mounting hole tolerance: 0.25 (0.02) weight: 191 g (6.74 oz) 5 46 37 1 2 t op view 100.0 112.0 (3.94) (4.41) 6.0 (0.24) 63.8 (2.51) 6.9 (0.27) 50.0 (1.97) 4 x ?3.5 92.0 (3.62) 10.0 (0.39) 25.6 (1.01) 5.0 (0.20) 11.8 (0.46) http://www.tracopower.com page 9 of 11 ac/dc power modules tmp series 7 to 60 watt outline dimensions weight: 345 g (12.17 oz) tmp 60 models for pcb mount: dimensions in [mm], ( ) = inches case tolerances: 0.5 (0.02) pin pich tolerance: 0.25 (0.01) mounting hole tolerance: 0.25 (0.02) pin diameter: 2.0 (0.08) 1 2 4 6 67.5 33.75 81.3 89.0 (2.66) (1.33) bottom view (3.20) (3.50) 3 7 27.94 (1.10) 12.70 (0.50) 15.24 (0.60) 2 x m3.5 thd 27.5 (1.08) 3.85 (0.15) 5.55 (0.219) 27.05 (1.065) 12.70 (0.50) 15.24 (0.60) 27.94 (1.10) 34.0 0.5 6.0 5.0 (0.02) (0.24) (1.34) (0.20) 5.0 (0.20) pin single 1 ac (n) 2 ac (l) 3 no pin 4 +vout 6 Cvout 7 no pin pin-out http://www.tracopower.com page 10 of 11 ac/dc power modules tmp series 7 to 60 watt outline dimensions tmp 60 models for chassis mount: (ntc = not to connect) dimensions in [mm], ( ) = inches case tolerances: 0.5 (0.02) mounting hole tolerance: 0.25 (0.02) weight: 357 g (12.95 oz) pin single 1 ac (n) 2 ac (l) 3 ntc 4 +vout 5 ntc 6 Cvout 7 ntc connection 5 46 37 1 2 t op view 100.0 112.0 (3.94) (4.41) 6.0 (0.24) 67.8 (2.67) 8.9 (0.35) 50.0 (1.97) 4 x ?3.5 92.0 (3.62) 10.0 (0.39) 38.0 (1.50) 5.0 (0.20) 11.8 (0.46) j enatschstrasse 1 ch-8002 zurich switzerland t el. +41 43 311 45 11 fax +41 43 311 45 45 info@traco.ch www .tracopower .com page 11 of 11 ac/dc power modules tmp series 7 to 60 watt din-rail mounting kit order code for models tmp-mk1 tmp 15xxxc tmp-mk2 tmp 30xxxc & tmp 60xxxc din-rail mounting kit rev. 03/09 adapter for mounting on din-rails as per en 50022-35 (snap-on mounting) specifcations can be changed any time without notice. kit contains interface plate, din-rail clip and necessary screws. |
Price & Availability of TMP15148
![]() |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |