134 page 1 specifications are subject to change without notice ?004 teledyne relays www.teledynerelays.com 134/0704/q1 est ablished reliability series 134 centigrid ? established reliability relays sensitive dpdt description the 134 sensitiv e centig rid ? rela y retains the same f eatures as the 114 standard centigrid ? relay with only a minimal increase in profile height (.375 in.). its .100-inch grid spaced terminals, which preclude the need for spreader pads, and its low profile make the 134 relay ideal for applications where high packaging density is important. the following unique construction features and manufacturing techniques provide excellent resistance to environmental extremes and overall high reliability: ? all welded construction. ? unique uni-frame design providing high magnetic efficiency and mechanical rigidity. ? high force/mass ratios for resistance to shock and vibration. ? advanced cleaning techniques provide maximum assurance of internal cleanliness . ? precious metal alloy contact material with gold plating assures excellent high current and dry circuit switching capabilities. the series 134d and 134dd have internal discrete silicon diodes for coil suppression and polarity reversal protection. the sensitiv e 134 centigrid ? rela y has a high resistance coil, thus requiring extremely low operating power (200 mw typical). the advantages of reduced heat dissipation and po wer supply demands are a plus. by virtue of its inherently low intercontact capacitance and contact circuit losses, the 134 relay has proven to be an excellent ultraminiature rf switch f or frequency ranges well into the uhf spectrum. a typical rf application for the centig rid ? rela y is in handheld radio transceivers, wherein the combined f eatures of good rf perf ormance, small size, low coil power dissipation and high reliability make it a preferred method of transmit-receive switching (see figure 1). internal construction series designation relay type 134 dpdt basic relay 134d dpdt relay with internal diode for coil transient suppression 134dd dpdt relay with internal diodes for coil transient suppression and polarity reversal protection upper stationary contact lo wer st ationary cont act moving contact uni-frame arma ture envir onmental and physical specifica tions t emperature (ambient) C5 to +125c vibration (general note 1) 30 gs to 3000 hz shoc k (gener al note 1) 75 g s, 6 msec , half-sine acceleration 50 g s enc losure her metically sealed w eight 0 .15 oz. (4.3g) max.
performance cur ves (no te 2) ?003 teledyne relays specifications are subject to change without notice 134 page 2 www.teledynerelays.com 134/1203/q1 est ablished reliability series 134 general electrical specifica tions (C5?to +125? nless otherwise noted) (notes 2 & 3) detailed electrical specifications (C5?to +125? nless otherwise noted) (note 3) contact arrangement 2 form c (dpdt) rated duty continuous contact resistance 0.1 ohm max. before life; 0.2 ohm max. after life at 1a/28vdc (measured 1/8" from header) contact load ratings (dc) (see fig. 2 for other dc resistive voltage/current ratings) resistive: 1 amp/28vdc inductive: 200 ma/28vdc (320 mh) lamp: 100 ma/28vdc low level: 10 to 50 ?/10 to 50mv contact load ratings (a c) resistiv e: 250 ma/115vac, 60 and 400 hz (case not grounded) 100 ma/115v ac, 60 and 400 hz (case grounded) contact life ratings 10,000,000 cycles (typical) at low level 1,000,000 cycles (typical) at 0.5a/28vdc resistive 100,000 cycles min. at all other loads specified above contact overload rating 2a/28vdc resistiv e (100 cycles min.) contact carry rating contact factory coil operating power 200 milliwatts typical at nominal rated voltage @ 25 operate time 4.0 msec max. at nominal rated coil voltage release time 134 series: 2.0 msec max. 134d, 134dd series: 7.5 msec max. contact bounce 1.5 msec max. intercontact capacitance 0.4 pf typical insulation resistance 10,000 megohms min. between mutually isolated terminals dielectric strength atmospheric pressure: 500 vrms/60hz 70,000 ft.: 125 vrms/60hz negative coil transient (vdc) 134d, 134dd 1.0 max diode p.i.v. (vdc) 134d, 134dd 100 min. base part numbers (see note 8 for full p/n example) 134-5 134d-5 134dd-5 134-6 134d-6 134dd-6 134-9 134d-9 134dd-9 134-12 134d-12 134dd-12 134-18 134d-18 134dd-18 134-26 134d-26 134dd-26 coil voltage (vdc) nom. 5.0 6.0 9.0 12.0 18.0 26.5 max. 7.5 10.0 15.0 20.0 30.0 40.0 coil resistance (ohms ?0% @25? 134, 134d 100 200 400 800 1600 3200 134dd (note 4) 64 125 400 800 1600 3200 coil current (madc @25) (134dd series) min. 56.8 36.3 18.1 12.5 9.6 7.2 max. 78.1 48.9 23.6 16.0 12.2 9.0 pick-up voltage (vdc, max.) 134, 134d 3.5 4.5 6.8 9.0 13.5 18.0 134dd 3.7 4.8 8.0 11.0 14.5 19.0 drop-out voltage (vdc) 134, 134d min. 0.12 0.18 0.35 0.41 0.59 0.89 max. 2.5 3.2 4.9 6.5 10.0 13.0 134dd min. 0.7 0.8 0.9 1.0 1.1 1.3 max. 2.6 3.0 4.5 5.8 9.0 13.0 0 .1.2 .3 .4 1020 30 40 50 60 70 .01 0.5 .1 .5 1.0 frequency (ghz) figure 1 typical rf performance insertion los s return l oss (vsw r) isolation across contact s isolation across poles 1.92 1.221.07 1.02 1.01 1.001.00 vswr 300 250200 150 100 50 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 load current (amps dc) figure 2 typical dc cont act ra ting (resistive) load vol tag e (vdc) db
134 page 3 specifications are subject to change without notice ?004 teledyne relays www.teledynerelays.com 134/0704/q1 est ablished reliability outline dimensions general notes 1. relay contacts will exhibit no chatter in excess of 10 sec or transfer in excess of 1 sec. 2. ypical characteristics are based on available data and are best estimates. no on-going verification tests are performed. 3. unless otherwise specified, parameters are initial values. 4. for reference only. coil resistance not directly measurable at relay terminals due to internal series diode in 134dd only. 5. unless otherwise specified, relays will be supplied with either gold-plated or solder- coated leads. 6. the slash and characters appearing after the slash are not marked on the relay. 7. screened hi-rel versions available. contact factory. 8. schema tic diagrams schematics are viewed from terminals 134 134d 134dd series 134 te l edyne par t numbering system f or t 2 r ? e stablis hed reliability r elay er 134 z m4 - 26 a / s q e st a bli s h ed r el i ab i li ty d es i gn a to r pad option (see appendix) r elay ser ies ground pin option (see appendix) q= solder-coated leads g= gold-plated leads (notes 5 and 6) s= .187" leads (note 6) coil voltage screening and reliability level te l edyne par t numbering system f or m ilitary qualified (ja n) r elays j 134 z m4 - 26 p l m il i ta r y (ja n ) d es ig na t or pad option (see appendix) r elay ser ies ground pin option (see appendix) te r minal v ariant p = 0.187" coil voltage screening and reliability level case detail .375 (9.53) sq. max. .335 (8.51) sq. max. .375 (9.53) max. dimensions are sho wn in inches (millimeters) terminal loca tions (view ed from te r minals; numbers f or reference only) .017 (.43) dia. +.002 (.05) C .001 (.03) wire lead .750 (19.05) min. pin: .187 (1.75) .010 (.25) (see note 5) .031 .003 (.79 .08) .035 .010 (.89 .25) .100 .010 (2.54 .25) typ 8 places 4 7 6 5 8 1 2 3
teledyne relays part numbering system er 114 y m4 - 26 a / s q established reliability designator relay series ground pin option (see appendix a) pad option (see appendix a) q = solder-coated leads g = gold-plated leads (rohs compliant) * parts ordered without suffx may be received with solder-coated or gold-plated leads. s = 0.187 leads w = 1.5 leads no suffx = 0.75 leads screening and reliability level (see appendix for screening options b) nominal coil voltage (26 = 26.5 v) t 2 r established reliability relays j 114 z m4 - 26 p l military (jan) designator relay series ground pin option (see appendix a) pad option (see appendix a) p = 0.187 leads w = 1.5 leads no suffx = 0.75 leads screening and reliability level (see appendix for screening options b) nominal coil voltage (26 = 26.5 v) military qualifed (jan) relays rf100 x - 26 / s q relay series ground pin option (see appendix a) * not applicable for grf relays q = solder-coated leads g = gold-plated leads (rohs compliant) * parts ordered without suffx may be received with solder-coated or gold-plated leads. s = 0.187 leads no suffx = 0.75 leads * not applicable for grf relays nominal coil voltage (26 = 26.5 v) rf relays rf attenuator relays a150 - 20 - 26 / s q relay series attenuation value (db) q = solder-coated leads g = gold-plated leads (rohs compliant) * parts ordered without suffx may be received with solder-coated or gold-plated leads. s = 0.187 leads no suffx = 0.75 leads nominal coil voltage (26 = 26.5 v) (800) 284-7007 ? www .teledynerelays.com ? +44 (0) 1236 453124 ? www.teledyne-europe.com ? 2008 teledyne relays
screening leve ls in sp ec t ion applicable to a level 1.5%/10k c ycles b level .75%/10k c ycles ja n l level 3%/10k c ycles ja n m level 1%/10k c ycles subgroup 1 screening, internal moisture aql x x x x vibration (sinusoidal) aql x vibration (sinusoidal) 100% x x screening, burn-in (hybrids only) x x x screening, run-in (room temperature) x screening, run-in (+125c and C65c) x x x subgroup 2 coil resistance or coil current x x x x insulation resistance x x x x dielectric withstanding voltage x x x x static contact resistance x x x x pickup and dropout or set and reset voltage x x x x operate and release or set and reset time x x x x hold voltage x x turn-on and turn-off time (hybrids only) x x x x contact bounce time x x contact stabilization time x x turn-on current (t hybrids only) x x x x turn-on voltage (c hybrids only) x x x x turn-off voltage (hybrids only) x x x x coil transient suppression (d, dd and hybrids only) x x x x diode blocking integrity (dd only) x x x x zener voltage (c hybrid only) x x x x neutral screen (latching relays only) x x x x break before make verifcation x x contact simultaneity x x subgroup 3 solderability 2 samples per daily solderability inspection lot x x x x leak test x x x x external visual and mechanical inspection 2/lot for dimension and weight check x x x x appendix b: teledyne relays t 2 r program ? 2008 teledyne relays
|