visit our website at: www.panduit.com/ncg network connectivity group spec sheet specifications technical information key features and ...benefits applications sc fiber optic adapters shall be compliant with tia focis-3. each simplex sc adapter shall connect one sc connector pair in one module space. each duplex sc adapter shall connect two sc connector pairs in two module spaces. all sc adapters and adapter modules are available with phosphor bronze or zirconia ceramic split sleeves and can be used for singlemode or multimode applications. sc fiber optic adapter ? robust design network reliability; exceeds requirements of tia/eia-568-b.3 focis-3 compliant ensures intermatability with all focis-3 compliant components high glass transition improved reliability; meets telcordia gr-326-core, issue 3; temperature latch material maintains latch integrity/geometry in high temperature (tg>100c) environments v-0 flammability rating on meets telcordia gr-326-core, issue 3 housing and inner latches integrated retention clip improved mounting; clip automatically adjusts for focis-3 compliant panel thickness variations, creating a snug fit to reduce rattles; no metal clips to become bent or damaged improved adapter maximum protection from contamination; protective cap fully protective cap design surrounds split sleeve opening choice of phosphor bronze provides an adapter split sleeve material option to fit specific or zirconia ceramic network requirements split sleeves q.c. number and split assures 100% traceability; quick and easy identification of sleeve material laser split sleeve material; sc-p = phosphor bronze and marked on every adapter sc-z = zirconia ceramic m ini -c om ? module design system flexibility; adapter modules can be used in all m ini -c om closet products and work area outlets adapters available in provides a complete sc system solution patch panels and fiber optic adapter panels (faps) adapter and module allows color-coding for network segregation available in multiple colors short flange design improved modularity and higher density usage panduit sc adapters can be used with m ini -c om modules, patch panels, faceplates and surface mount boxes for a complete sc system solution. sc adapters provide a robust solution for lans, public networks, storage area networks and fiber-to-the-desk applications. sc adapters can be mounted in high density applications within o pticom ? and o pticom hd ? enclosures. split sleeve material: phosphor bronze or zirconia ceramic insertion loss: 0.10db typical* (multimode), 0.15db typical* (singlemode); supports the performance of focis-3 compliant connectors/patch cords return loss: supports singlemode(>40db for spc and >55db for upc) and multimode(>20db) connector polish performance sc adapter module with phosphor bronze split sleeves duplex: cmdeisc** simplex: cmseisc** adapter color: electric ivory; to change adapter color substitute bu (blue) for ei sc adapter module with zirconia ceramic split sleeves duplex: cmdbuscz** simplex: cmsbuscz** adapter color: blue; to change adapter color substitute ei (electric ivory) for bu multimode 900m tight-buffered fiber or 3mm jacketed cable black boot: fscmbl red boot: fscmrd singlemode 900m tight-buffered fiber or 3mm jacketed cable blue boot: fscsbu sc/upc terminator (singlemode) simplex: ftrm-sc1 multimode patch cords o pti -p lug ? duplex connector to sc: f6d6p-3m? simplex 900m buffered sc pigtails: f6b3-nm? simplex sc to sc: f6s3-3m? duplex sc to sc: f6d3-3m? duplex st to sc: f6d2-3m? duplex sc to fc: f6d3-4m? singlemode patch cords o pti -p lug duplex connector to sc: f9d6p-3m? simplex 900m buffered sc pigtails: f9b3-nm? simplex sc to sc: f9s3-3m? duplex sc to sc: f9d3-3m? duplex st to sc: f9d2-3m? duplex sc to fc: f9d3-4m? **substitute for module color: ei = electric ivory bu = blue wh = white bl - black iw = off white ig = international gray please contact factory for additional patch cord configurations and custom lengths. ?available in standard lengths of 1, 2, 3 and 10 meters installer tip before making connections, always clean adapter split sleeves and ferrule endfaces. always insert protective caps into unused ports to prevent contamination. * panduit ? sc connector/adapter connection
sc fiber optic adapter our products are warranted to be free from defects in material and workmanship at the time of sale but our obligation under this warranty is limited to the replacement of any product proved to be defective within 6 months (for product) or 90 days (for tools) from the date of delivery. tool warranty is void if panduit tools are modified, altered or misused in any way. use of panduit tooling with any product other than the specified panduit products for which the tool was designed, constitutes misuse. before using, user shall determine the suitability of the product for his intended use and user assumes all risk and liability whatsoever in connection therewith. this warranty is made in lieu of and excludes all other warranties, expressed or implied. the implied warranties of merchantability and fitness for a particular use are specifically excluded. neither seller nor manufacturer shall be liable for any other injury, loss or damage whether direct or consequential, arising out of the use of, or the inability to use, the product. the information contained in this literature is based on our experience to date and is believed to be reliable. it is intended as a guide for use by persons having technical skill at their own discretion and risk. we do not guarantee favorable results or assume any liability in connection with its use. dimensions contained herein are for reference purposes only. for specific dimensional requirements consult the factory. this publication is not to be taken as a license to operate under, or a recommendation to infringe any existing patents. this supersedes and voids all previous literature, etc. network connectivity group panduit canada div. of panduit corp. markham, ontario phone: 905-475-6922 european headquarters panduit europe ltd. london, uk phone: 44(0) 208-601-7200 panduit corp. japan branch phone (81) (3) 3767-7011 asian headquarters panduit singapore pte. ltd. republic of singapore phone: (65) 379 6700 panduit (aust.) pty. ltd. phone: (61) 3-9794 9020 panduit mexico/latin america & caribbean phone: (52) 3 666-2501 world headquarters panduit corp. tinley park, illinois, usa phone: 888-506-5400, ext. 6914 708-532-1800, ext. 6914 fax: 708-460-2897 email: info@panduit.com internet: www.panduit.com/ncg worldwide subsidiaries and sales offices for pricing and further information ? contact your local authorized panduit p an -n et ? distributor or sales office ? panduit corp. 2001 all rights reserved sa-nc10sp01e printed in u.s.a. dimensions are in inches (dimensions in brackets are in millimeters) ? standards compliant performance* tia 455 iso/iec 874-1 description test procedure and tia/eia-568-b.3 required performance performance 1 -- flex 100 cycles; -180 to 180 degrees; max. insertion loss 0.75db, min. return loss 20db (mm), 26db (sm) < 0.1db additional loss 2 4.5.11 impact 8 drops from 1.8m; max. insertion loss 0.75db, min. return loss 20db (mm), 26db (sm) < 0.1db additional loss 4 4.5.18 high temperature 4 days at 60c followed by post-conditioning fotp-6; max. insertion loss 0.75db, min. return loss 20db (mm), 26db (sm) < 0.1db additional loss 21 4.5.32 durability 500 mate/unmate cycles; max. insertion loss 0.75db, min. return loss 20db (mm), 26db (sm) < 0.1db additional loss 36 4.5.5 twist 10 cycles; 2.5 cw, 5 ccw, 2.5 cw; max. insertion loss 0.75db, min. return loss 20db (mm), 26db (sm) < 0.1db additional loss 185 4.5.6 coupling strength 7.4 lbs. at 0 degrees; max. insertion loss 0.75db, min. return loss 20db (mm), 26db (sm) < 0.1db additional loss 188 4.5.17 low temperature 4 days at 0c; max. insertion loss 0.75db, min. return loss 20db (mm), 26db (sm), max. change during test 0.3db < 0.1db additional loss 34 4.4.7 insertion loss max. insertion loss 0.75db, min. return loss 20db (mm), 26db (sm) 0.10db typical (mm), 0.15db typical (sm) 107 -- return loss 20db minimum (mm), 26db minimum (sm) >20db (mm), >40db (sm) 5 4.4.19 humidity 4 days at 90-95% rh and 40c; max. insertion loss 0.75db, min. return loss 20db (mm), 26db (sm), max. change during test 0.4db < 0.1db additional loss 6 4.5.4 cable retention 11.24 lbs. at 0 degrees, 4.4 lbs. at 90 degrees; max. insertion loss 0.75db, min. return loss 20db (mm), 26db (sm), max. additional loss 0.5db < 0.1db additional loss * panduit ? sc connector/adapter connection note: multimode tests performed at 850 and 1300nm. singlemode test performed at 1310 and 1550nm. .076 [1.9] .585 [14.9] .367 [9.3] .120 [3.0] 1.079 [27.4] .076 [1.9] .367 [9.3] .120 [3.0] 1.079 [27.4] .62 [15.8] 1.121 [28.5] .71 [18.0] 1.37 [34.8] 1.24 [31.5] .71 [18.0] 1.37 [34.8] m ini -c om ? sc simplex adapter module m ini -c om sc duplex adapter module sc simplex adapter sc duplex adapter
|