  132 catalog 1654001 dimensions are in inches and dimensions are shown for usa cust. svc.: 1-800-468-2023 www.corcom.com revised 05-07 millimeters unless otherwise reference purposes only. corcom prods: 1-847-680-7400 www.tycoelectronics.com specified. values in italics specifications subject germany: 49-89-6089-0 are metric equivalents. to change. p series p series corcom product guide the chameleon adaptable module for general, high performance or m edical applications the p series power entry module offers fuller flexibility of design in a more compact package. as the first 10 amp module to provide all five power entry functions in one compact design, the chameleon module readily adapts to its environment and the needs of international markets. ? snap-in or flange mounting ? iec power line connector ? both north american and european fusing capabilities ? two voltage selections ? optional dpst on/off switch ? filtering options for general purpose, medical and high-performance applications. the chameleon modules compact design and modular construction will allow you to select the power entry features you require without altering the panel cutout. and the chameleon module, with adapters, will fit any standard panel cutout. the chameleon module has four filter options. s models offer protection for general purpose applica- tions where line-to-ground and line-to-line noise must be controlled. the filters are designed to meet low leakage requirements of vde portable equipment. they are available in current ratings of 3, 6 and 10 amps. h models provide susceptibility protection without leak- age current associated with line-to-ground capacitors and are designed to allow equipment to meet ul 544 for patient care and non-patient care equipment. also available is an interconnection block, b models . the block connects the voltage selection terminals of an unfiltered chameleon module with a switch and an iec connector to reduce external wiring. l models Chigh performance medical filter versions that are designed to help bring most digital equipment (includ- ing switching power supplies) into compliance with en55022, level b (as well as fcc part 15j, class b) conducted emissions limits while additionally allowing equipment to meet ul544, ul2601and en60601 for patient care equipment and non-patient care equipment. they are available with current ratings of 6 and 10 amps. high performance versions are available with horizontal mount - ing ears, single voltage, complete can shield with options for switch, fuses and current ratings only. extenders are not available. z models Chigh performance filter versions are designed to help bring most digital equipment (including switching power supplies) into compliance with en55022, level b (as well as fcc part 15j, class b) conducted emissions limits. they are available with current ratings of 6 and 10 amps. high performance versions are available with horizontal mounting ears, no extenders, single voltage, complete can shield with options for switch, fuses and current ratings only. ps000ss30 ps unfiltered p s filtered pe filter with "a" shield ul recognized csa certified vde approved
133 catalog 1654001 dimensions are in inches and dimensions are shown for usa cust. svc.: 1-800-468-2023 www.corcom.com revised 05-07 millimeters unless otherwise reference purposes only. corcom prods: 1-847-680-7400 www.tycoelectronics.com specified. values in italics specifications subject germany: 49-89-6089-0 are metric equivalents. to change. p o w e r e n t r y m o d u l e s corcom product guide p series part number schematic part numbers are constructed by selecting the alphanumeric character which represents the desired feature. additional extender which allows the p series to adapt to corcom's l series product cutout, as well as the panel cutout of schaffner and delta parts is available. * extenders cannot be added to units with b shields. p series the part number psj0xss60 would represent the equivalent of the corcom j series 6j4:. p series ( p ) with a snap-in mount ( s ) with the j extender to fit the 6j4 cutout(j), and includes no switch ( 0 ) dual voltage select ( x ) single fusing ( s ), general purpose filter ( s ) for 6 amps ( 6 ) with no shield ( 0 ). the chameleon adaptable module for general, high performance or m edical applications (continued) notes: an additional extender which allows the p series to adapt to corcom's l series product cutout as well as the panel cutout of schaffner and delta parts is also available. extenders cannot be added to units with b shields ? when using the interconnection block, the last 3 digits of the part number are bx (0, a, or b) for alternative switch orientation options, please contact technical sup port or your corcom sales representative ** dual voltage options only available with filter types o, h or s high performance versions are available with horizontal mounting ears (pe style), no extenders, single voltage, complete can shield with options for switch, fuses, filter type (l or z) and 6 or 10 amp current ratings only. p s j0xs s 6 0 m ounting style e = mounting ears (horizontal) s = snap-in m = mounting ears ( vertical) extender option 0 = none c = fn260 j = j series l = l series s witch option 0 = blank s = double pole single throw (dpst) input voltage select 0 = single voltage s = dual voltage select (smps) x = dual voltage select (series/parallel) f use options d = dual fuse s = single fuse filter type 0 = no filter b = interconnection block = h = medical filter l = high performance medical s = general purpose z = high performance f ilter current 0 = no filter 3 = 3 amps 6 = 6 amps x = 10 amps shield options 0 = no shield a = filter shield b = complete shield c = complete can (for l & z models) mounting style extender options* switch options voltage select fuse options filter type filter current shield options* ** ? ** ** *** extender for j-series or others optional filter optional switch fuse holder
input voltage selection schemes x - dual primary transformer type s - jumper type 134 catalog 1654001 dimensions are in inches and dimensions are shown for usa cust. svc.: 1-800-468-2023 www.corcom.com revised 05-07 millimeters unless otherwise reference purposes only. corcom prods: 1-847-680-7400 www.tycoelectronics.com specified. values in italics specifications subject germany: 49-89-6089-0 are metric equivalents. to change. corcom product guide note 1: jumpers are required if a filter or interconnection module is not used. note 2: location of optional filter. jumpers are required if a filter or interconnection block is not used. the p series of power entry modules provides a dual volt- age selector which is integrated with the fuseholder. to simplify the wiring in each individual application, tyco electronics provides dedicated voltage selectors for differ- ent voltage selection schemes. the two most popular schemes are the parallel and serial for dual primary trans- formers and the pst switch?or switching mode power supplies (jumper types.) p series products with an ?s the fifth digit are specifically designed for umper?ype applications associated with switching mode power sup- plies. p series products with an ?s the fifth digit are specifically designed for dual primary transformer applica- tions. the voltage selector installed will allow proper wiring from these applications. no matter what voltage selection scheme is used, wiring is always made to the same four terminals. p series voltage selection a shield b shield the chameleon adaptable module for general, high performance or m edical applications (continued) shield a new feature available on the p series is an rf shield. the metal shield, available on filtered models, provides shield - ing from radiated emissions and provides an additional rf ground for the filter to the case. the shield is available in two versions, a shield of the filter components (designated by a as the ninth digit) and a complete shield (designated by b as the ninth digit). the a shield covers the filter por - tion of the module and increases performance of the filter by protecting the components from magnetic coupling. this shield improves rf ground connection to the case while still allowing the use of the p series extender. the b shield covers the entire power entry module with metal, protecting the equipment from all radiated noise. used with the filter, the shield provides the most secure protec- tion from rfi noise problems. the b shield cannot be used with any extender. 1 15v 230v n ote 1 note 2 note 2 note 1 a b c d p ower on/off 1 15v 115v neutral provision for s ingle fusing transformer primary g h hot ground 115v 230v note 1 note 1 n ote 1 note 1 a b c d power on/off neutral provision for single fusing g h power input sel. jumpers smps hot ground
the chameleon adaptable module for general, high performance or medical applications (continued) 135 catalog 1654001 dimensions are in inches and dimensions are shown for usa cust. svc.: 1-800-468-2023 www.corcom.com revised 05-07 millimeters unless otherwise reference purposes only. corcom prods: 1-847-680-7400 www.tycoelectronics.com specified. values in italics specifications subject germany: 49-89-6089-0 are metric equivalents. to change. p o w e r e n t r y m o d u l e s p series corcom product guide fuseholder a nother feature of the p series power entry module is a ver- satile fusing arrangement. its fuseholder can hold two 1/4 x 1-1/4or 5 x 20mm fuses. it can also be converted to accept one fuse with a conversion clip that bridges one of the two fuse chambers. the conversion clip is installed on the p series power entry modules set for single fusing (those with part numbers with an ?s the sixth digit). units with a ?s the sixth digit do not include a conver- sion clip. interconnection block also available is an interconnection block (b models). the block connects the voltage selection terminals of an unfil - tered chameleon module with a switch and an iec con- nector to reduce external wiring. installation of the unfil - tered versions of the p series involves wiring of the iec socket to the switch and the switch to the fuseholder. labor can be eliminated by ordering the product with an intercon- nection block. this feature, designated by a bx in the sev- enth and eighth digits, pre wires the module for easier installation. the wiring is protected with the plastic case to better prevent access to the terminals and connections. the dimensions of this alternative are the same as the filtered versions. accessories a full range of accessories are available for the p series. to simplify customer installation wiring can be simplified by ordering a pa100 connector assembly which is pre-wired with 6" of wire lead. see page 143 for a complete list of all accessories available for this series. interconnection block installed in place of filer. fuseholder shown with 5x20mm fuse conversion clip included for use in single fuse applications. pa100 assembly
136 catalog 1654001 dimensions are in inches and dimensions are shown for usa cust. svc.: 1-800-468-2023 www.corcom.com revised 05-07 millimeters unless otherwise reference purposes only. corcom prods: 1-847-680-7400 www.tycoelectronics.com specified. values in italics specifications subject germany: 49-89-6089-0 are metric equivalents. to change. p series corcom product guide the chameleon adaptable module for general, high performance or medical applications (continued) specifications maximum leakage current, each line-to-ground: ? h & l models s & z models @ 120 vac 60 hz: 2 a .25 ma @ 250 vac 50 hz: 5 a .50 ma ?applies to filtered models only hipot rating (one minute): line-to-ground 1500 vac line-to-line 1450 vac operating frequency: 50/60 hz rated voltage: 250 vac operating voltages: selectable or fixed 115/230 vac rated current: unfiltered C10a filtered C3, 6 or 10a switch: double-insulated, rated for 10,000 operations at full load at 51 amp inrush current. fuseholder: accepts one or two fuses 1/4 x 1-1/4 or 5 x 20 mm conversion clip provided on fuseholder for single fuse models. terminals: standard versions: .187 x 0.032 [ 4.8 x .81 ] terminal tabs high performance versions: .250 x 0.032 [ 6.4 x .81 ] terminal tabs recommended for use with mating connector - no solder minimum insertion loss in db: l ine-to-ground in 50 ohm circuit current frequency-mhz r ating .03 .1 .15 .5 1 3 5 10 30 h models 0 3a 7 17 21 27 30 29 26 23 15 0 6a - 8 11 15 17 19 18 16 13 10a 3 5 8 10 12 11 11 10 10 s models 0 3a 7 17 21 27 33 40 44 50 32 0 6a - 8 12 17 23 32 36 44 30 10a - 3 5 10 13 23 27 35 27 current frequency-mhz rating .01 .05 .1 .15 .5 1 5 10 30 z models 0 6a 8 21 27 30 37 43 49 52 42 10a 5 17 22 24 27 32 52 47 40 l models 0 6a 8 21 27 29 34 35 25 21 16 10a 5 17 22 23 24 25 21 18 14 line-to-line in 50 ohm circuit current frequency-mhz rating .10 .15 .5 1 3 5 10 30 h models 0 3a 2 4 12 18 31 40 48 41 0 6a 2 4 12 16 26 35 40 35 10a 2 4 12 16 26 33 40 32 s models 0 3a 2 4 12 15 30 48 50 45 0 6a 2 4 12 15 22 42 55 45 10a 2 4 12 15 22 42 55 45 current frequency-mhz rating .01 .05 .1 .15 .5 1 5 10 30 z models 0 6a 10 15 34 44 75 75 75 70 60 10a 10 20 20 35 67 75 75 70 60 l models 0 6a 10 15 34 44 75 75 75 70 60 10a 10 20 20 35 67 75 75 70 60 s model h model l model z model electrical schematics line load line load
137 catalog 1654001 dimensions are in inches and dimensions are shown for usa cust. svc.: 1-800-468-2023 www.corcom.com revised 05-07 millimeters unless otherwise reference purposes only. corcom prods: 1-847-680-7400 www.tycoelectronics.com specified. values in italics specifications subject germany: 49-89-6089-0 are metric equivalents. to change. p o w e r e n t r y m o d u l e s p series corcom product guide the chameleon adaptable module for general, high performance or m edical applications (continued) case styles ps/psl pe n ote1: for snap-in applications, the d sides of the cutout must have a .02 [ . 508 ] radius on the installation side. snap-in models allow front mounting only. not recommended for plastic panels. pm typical dimensions: terminals: .187 x 0.032 [ 4.8 x .81 ] terminal tabs holes: .055 [ 1.5 ] dia. .004 [ .10 ] slot (ground terminal): .06 x .115 [ 1.52 x 2.92 ] .004 [ .10 ] mounting holes (pe, pm only) : .135 [ 3.43 ] dia. (2) countersunk b2 c .225 5.72 a .225 5 .72 b1 c un? tered f ilt ered d e .06 1.52 r max .020 .508 r min (no te 1) p anel cutout b1 c .225 5.72 a f d max. b2 c .225 5.72 max. un? tered f ilt ered d e . 06 1.52 r max .020 .508 r min f p anel cutout un? tered f ilt ered d f c a b1 .225 5.72 max. b2 .225 5.72 max. e f d .06 1.52 r max p anel cutout
138 catalog 1654001 dimensions are in inches and dimensions are shown for usa cust. svc.: 1-800-468-2023 www.corcom.com revised 05-07 millimeters unless otherwise reference purposes only. corcom prods: 1-847-680-7400 www.tycoelectronics.com specified. values in italics specifications subject germany: 49-89-6089-0 are metric equivalents. to change. p series corcom product guide pe high performance note 1: for snap-in applications, the d sides of the cutout must have a .02 [ .508 ] radius on the installation side. snap-in models, allow front mounting only. note 1: use cutout for pe style. case styles (continued) the chameleon adaptable module for general, high performance or m edical applications (continued) typical dimensions: terminals: .187 x 0.032 [ 4.8 x .81 ] terminal tabs holes: .055 [ 1.5 ] dia. .004 [ .10 ] slot (ground terminal): .06 x .115 [ 1.52 x 2.92 ] .004 [ .10 ] mounting holes (pe, pm only) : .135 [ 3.43 ] dia. (2) countersunk typical dimensions: terminals: .250 x 0.032 [ 6.4 x .81 ] terminal tabs holes: .07 [ 1.8 ] dia. (2) slot (ground terminal): .07 x .16 [ 1.8 x 4.1 ] mounting holes: .135 [ 3.43 ] dia. (2) countersunk psc/psj un? tered f ilt ered a b1 c . 225 5 .72 max. b 2 .225 5 .72 d e .06 1.52 r max .020 .508 r min (no te 1) panel cutout a c 3.93 max. b2 2.17 max. f .225 5.72 d rear view 2.39 m ax.
139 catalog 1654001 dimensions are in inches and dimensions are shown for usa cust. svc.: 1-800-468-2023 www.corcom.com revised 05-07 millimeters unless otherwise reference purposes only. corcom prods: 1-847-680-7400 www.tycoelectronics.com specified. values in italics specifications subject germany: 49-89-6089-0 are metric equivalents. to change. p o w e r e n t r y m o d u l e s p series corcom product guide rear view case dimensions part no. a b1 b2 c d e f (max) (max) (max) (max) ps 1.24 1.93 2.13 2.31 1.06 ? ? 2.201 * 31.49 49.02 54.1 58.67 26.93 55.91 psl 1.24 1.93 2.13 2.31 1.12 2.201* 31.49 49.02 54.1 58.67 28.45 55.91 pe 1.98 1.93 2.13 2.31 1.122 2.201* 1.575 50.29 49.02 54.1 58.67 28.5 55.91 40.0 pm 1.24 1.93 2.13 2.9 1.06 2.13 2.496 31.49 49.02 54.1 73.66 26.93 54.1 63.4 psc 1.24 1.93 2.13 2.51 1.06 2.52 31.49 49.02 54.1 63.75 26.93 64.01 psj 1.24 1.93 2.13 2.72 1.06 2.6 + 31.49 49.02 54.1 69.09 26.93 66.0 pe 1.98 4.42 2.31 1.12 2.201 1.575 high 50.29 112.27 58.67 28.5 55.91 40.0 performance * panel cutout for thickness of .031 - .079 [ 0.8 - 2.0 ]. for panel thickness at .083 - .114 [ 2.1 - 2.9 ] use 2.213 [ 56.21 ] . + panel cutout for thickness of 0.06 - 0.09 [ 0.76 - 2.29 ]. ? ? for shielded models use d=1.12 +.008/-.000. + .008/-.000 +.20/-.00 +.008/-.000 +.20/-.00 the chameleon adaptable module for general, high performance or m edical applications (continued) shielding s hields can be used only with filtered models. shields add approximately 0.06" to depth. b shield may not be used with j or c extender. 2.19 max 0.225 .508 max. 0.225 .508 m ax. 2.19 max a shield b shield a bc d a bc d gnd gnd l n filt ered un? tered


▲Up To Search▲   

 
Price & Availability of PSC0XSS60

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X