Part Number Hot Search : 
74VHC04N LM358 7M035 GA168P IDTQS3 35005 7M035 00506
Product Description
Full Text Search
 

To Download KV-10 Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
  plc connection guide 1 plc connection guid altus alnet - i ................................ ............................. 2 bacnet bacnet/ip ................................ ...................... 6 barcode (usb/co m) ................................ ................. 17 baumuller ................................ ................................ ... 19 beckhoff ads/ams (ethernet) ................................ . 22 beckhoff embed ded pc ................................ ............. 29 canopen slave (for emt3000 only) ......................... 36 change ................................ ................................ ......... 39 cimon cm 1 - cp4a/eco1a ................................ ...... 41 cimon cm1 - sc02a ................................ ................... 43 copley controls ................................ .......................... 45 crouzet m3 (fbd) ................................ ................ 49 crouzet m3 (lad) ................................ ............... 52 danfoss ecl apex20 ................................ ................. 55 danfoss ecl apex20 (ethernet) ............................... 58 d anfoss fc series ................................ ....................... 60 danfoss vlt2800 series ................................ ............ 62 delta dvp ................................ ............................... 64 delta dvpen01 - sl (ethernet) ............................ 66 dl/t645 chuang hong ................................ ....... 68 dl/t645 standard ................................ ..................... 74 dl - bcm server ................................ ......................... 76 emerson charge module ................................ ...... 79 emerson plc ec20 ................................ .............. 81 fatek fb series ................................ ....................... 83 fuji nb series ................................ ............................. 89 ge f anuc 0i md ................................ ......................... 92 ge fanuc cmm ................................ ......................... 95 ge fanuc rx3i ................................ ........................ 100 ge fanuc s erie s 90 - 30 (ethernet) .......................... 104 ge fanuc snp - x ................................ ...................... 107 haiwell plc ................................ .............................. 112 hangzh ou maiou mo - tech ................................ .. 115 hanyoung controller ................................ ............... 117 hawe plvc ................................ ........................... 120 heng yuan eu series ................................ ............... 122 hitachi eh - sio ................................ ........................ 124 hitachi ehv series (ethernet) ................................ 129 hitachi h/eh/ehv series ................................ ....... 131 hust h4x ................................ ................................ 138 i ai x - sel controller ................................ .... 140 idec micro ................................ .............................. 143 inovance h2u/h1u ................................ .................. 147 justfi controller ................................ ....................... 150 kernel sistemi dmx series ................................ ...... 152 k eyence kv - 10/16/24/40/80/visual kv s eries .. 154 keyence kv - 5000 (ethernet) ............................. 157 keyence kv - 700/ 1000 /3000/5000 series ............ 159 korenix 6550 ................................ ............................. 161 koyo click ................................ .......................... 163 koyo direct ................................ ....................... 166 koyo ethernet ................................ ........................ 178 lenze ................................ ................................ .......... 181 lingyan bms ................................ ........................... 183 liyan ex series ................................ ...................... 185 loxin ................................ ................................ ......... 187 ls glofa cnet ................................ ....................... 189 ls glofa fe net (ethernet) ................................ .. 194 ls glofa gm3467 (loader) ........................... 196 ls master - k cnet ................................ ............... 198 ls master - k cpu direct ................................ .... 200 ls master - k modbus rtu ............................. 202 ls master - k10s1 ................................ ................ 204 ls xech cnet ................................ ......................... 206 ls xech fenet (ethernet) ................................ .... 209 ls xgb cnet ................................ ............................ 211 ls xgb fenet (ethernet) ................................ ....... 214 ls xgi cnet ................................ ............................. 217 ls xgi cpu direct ................................ ............. 221 ls xgi fenet (ethernet) ................................ ........ 224 l s xgk cnet ................................ ............................ 226 l s xgk fenet (ethernet) ................................ ....... 230 l s xgt/xgk cpu direct ................................ . 233 ls mecapion metronix anypack ............................ 236 master - slave server ................................ ................. 238 m emory map ................................ ............................ 241 www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 2 m ikom mx series plc ................................ ......... 245 mitsubishi a1s/a2n ................................ ................. 248 mitsubishi a2a/a2u/a2as/a2ush ....................... 251 mitsub ishi a3a/a3n/a1sh/a2sh ......................... 254 mitsubishi a2us ................................ ....................... 257 mitsubishi aj71 ................................ ........................ 260 mitsubishi aj71 (ana/anu cpu) .......................... 264 mitsubishi aj71 (format 4) ................................ .... 268 mitsubishi f930got server ................................ ... 272 mitsubishi fx0s/fx0n/fx1s/fx1n/fx2 ................ 275 mitsubishi fx232/485bd ................................ ......... 279 mitsubishi fx2n ................................ ....................... 284 mitsubishi fx3u (ethernet) ................................ .... 287 mitsubishi fx3u/fx3g ................................ ............ 294 mitsubishi melse c - q/l - ascii mode (ethernet) ................................ ................................ .................... 297 mitsubishi melsec - q/l - binary mode (ethernet) ................................ ................................ .................... 302 mitsubishi mr j3 a ................................ ................. 307 mitsubishi mr - mq100 (ethernet) ......................... 314 mitsubishi q00/q00uj/q01/qj71 .......................... 317 mitsubishi q00j ................................ ....................... 326 mitsubishi q00u/q01u/q02u/qnud/qnudh ..... 328 mitsubishi q00uj/qnu/qnud/qnudh/qnudeh/l (mini usb) ................................ ................................ 331 mitsubishi q02/02h ................................ ................. 333 mitsubishi q06h ................................ ...................... 336 mitsubishi qj71e71 (ethernet) .............................. 339 m odbus ascii ................................ ...................... 346 modbus ascii server ................................ .......... 351 m odbus rtu ................................ ......................... 355 modbus rtu (0x/1x range adjustable) ............. 360 modbus rtu (adjustable) ................................ ... 369 m odbus rtu (zero - based addressing) ................ 376 modbus server (com/ethernet) ........................ 381 modbus tcp/ip ................................ .................... 389 modbus tcp/ip (0x/1x range adjustable) ........ 391 m odbus tcp/ip (zero - based addressing) ........... 397 m odbus tcp/ip 32bit ................................ .......... 399 mo eller xc - cpu101 ................................ ................ 401 ohjx ................................ ................................ ......... 403 omron c/cqm1 s eries ................................ ........ 406 omron cj/cs /cp ................................ .................. 410 omron cj1/cs1 ( ethernet ) ................................ . 414 omron e5cn/e5ez/e5zn ................................ .. 416 omron fins (ethernet) ................................ ....... 420 omron host link ................................ .................. 422 panasonic fp ................................ ............................. 426 p anasonic fp (ethernet) ................................ .......... 434 p anasonic fp2 (ethernet) ................................ ........ 437 p anasonic minas a4 ................................ .............. 439 p anasonic minas a5 ................................ .............. 443 parker acr9000 ................................ ...................... 447 parker compax3 ................................ ...................... 449 parker compumotor 6k series ............................... 454 p arker slvd series ................................ ................. 456 rockwel l compactlogix - free tag names ........... 459 rockwell compactlogix/flexlogix ........................ 467 rockwell df1 ................................ ............................ 471 rockwell df1 (bcc) ................................ ................ 475 rockwell dh485 ................................ ....................... 479 rockwell ethernet/ip (compactlogix) .................. 484 rockwell ethernet/ip (compactlogix) C free tag names ................................ ................................ ........ 487 rockwell ethernet/ip (controllogix) C free tag names ................................ ................................ ........ 495 rockwell ethernet/ip (df1) ................................ ... 503 rockwell plc5 ................................ ......................... 506 rs automation oemax series .............................. 510 saia pcd pgu mode ................................ ............. 512 saia pcd s - bus mode ................................ .......... 514 saia s - bus ( ethernet) ................................ ........... 522 samsung spc - 10 ................................ ...................... 525 scene6 controller ................................ .................. 527 schleicher xcs 20c ................................ ................. 529 schleicher xcx 300 ................................ ................. 532 schneider modbus rtu ................................ ....... 537 schneider modbus tcp/ip ................................ .. 541 www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 3 schneider unitelway ................................ ............... 543 s ew movilink ................................ .......................... 545 sew movitrac lte ................................ .......... 547 shimaden mr13/fp93 ................................ ........ 551 shj - a ................................ ................................ ........ 563 sick flexi soft ................................ ................. 565 siemens logo (ethernet) ................................ ...... 567 siemens s7 - 1200 (ethernet) ................................ ..... 572 siemens s7 - 200 ................................ ......................... 578 siemens s7 - 200 (ethernet) ................................ ....... 581 siemens s7 - 200 (vd any address) ........................... 588 siemens s7 - 200 ppi ................................ .................. 591 siemens s7 - 300 ................................ ......................... 596 siemens s7 - 300 mpi ................................ ................ 604 siemens s7 - 300/et200s (ethernet) ........................ 612 siemens s7 - 400 (ethernet) ................................ ....... 618 siemens ti505 ................................ .......................... 626 siemens ti565/c400 ................................ ................. 632 sstc ssd series ................................ ...................... 638 techsoft intelligent servo ................................ . 650 t eco inverter ................................ ......................... 652 teco tp02 series ................................ ................... 6 55 teco tp03 series ................................ ................... 658 tinhao ................................ ................................ ... 661 toptek topvert ................................ ......................... 664 toshiba t series ................................ ................... 667 toshiba vf - s11 ................................ .................... 672 toshiba machine provisor tc200 ................. 675 trio modbus rtu, tcp/ip ................................ . 678 trio modbus rtu, tcp/ip (mode 7) ................. 683 vigor ................................ ................................ ...... 688 vipa 200 ................................ ................................ ... 692 vipa 200 (vd any address) ................................ .... 695 vipa 200, for ex. 214 - 2bt10 (ethernet) ................ 698 vipa 300 ................................ ................................ ... 700 vipa 300 mpi ................................ .......................... 708 vipa 300s (ethernet) ................................ .............. 716 vipa 300s, for ex. 315 - 4ne12 (e thernet) .............. 723 xinje xc series ................................ ...................... 729 yamaha ercd ................................ ..................... 731 yaskawa ccmep ................................ ............... 734 yaskawa memobus (mp series controllers) .... 736 yaskawa mp series ethernet (extension) ........ 743 yaskawa mp2300siec ................................ ......... 748 yaskawa smc 3010 ................................ ............ 757 yaskawa smc 3010 (ethernet) .......................... 761 yokogawa fa - m3 ................................ ............. 764 yokogawa fa - m3 (ethernet) ........................... 770 yudian aibus ................................ ....................... 772 mt6050i /mt8050i com port pin assignment ...... 776 www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 2 altus alnet - i supported s eries: altus seriesmode po3042, po3142, po3242, po3342, pl103 ,pl104, pl105, qk800, qk801, qk2000. hmi setting: parameters recommend ed option s notes plc type a ltus alnet - i plc i/f rs232 baud rate 9600 data b its 8 parity even stop bits 1 plc s t a . n o. 0 device a ddress: bit/word device type format range memo b m_bit ddddh 0 ~ 1023f memories b a dddh 0 ~ 511f auxiliary relays b e dddh 0 ~ 511f input relays b d_bit dddddd 0 ~ 102331 decimals b f_bit dddddd 0 ~ 102331 reals b i_bit dddddd 0 ~ 102331 integers b s dddh 0 ~ 511f output relays w m dddd 0 ~ 4096 memories dw d d ddd 0 ~ 4096 decimals dw f dddd 0 ~ 1023 reals dw i dddd 0 ~ 1023 integers w tm hhhh 0 ~ ffff* memory tables dw td hhhh 0 ~ ffff* decimal tables dw tf hhhh 0 ~ ffff* real tables dw ti hhhh 0 ~ ffff* integer tables www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 3 note: the formats of tm, td, tf and ti in plc software are represented as txa[b] . x can be m , d , f , or i . the address range of b is 0~ff, and a is 0~ff. the device type is aabb, and the range depends on the plc settings. for example : model po3242 , range of a is 0 and ra nge of b is 0 ~ 7. wiring d iagram: the following represents the view of hmi & plc. 9p d - sub to 8 p rj45 : plc po3042, po3142, po3242, po3342 e mt 3 000 series com1 rs232 9p d - sub fem ale com 3 rs232 9p d - sub fem ale plc rs232 8p rj45 male 2 rx 8 rx 2 t x 3 t x 7 tx 3 r x 5 gnd 5 gnd 5 gnd mt6000 /8000 series except mt6050i/mt8050i com1 rs232 9p d - sub fem ale com2 rs232 9p d - sub fem ale com3 rs232 9p d - sub m ale plc rs232 8p rj45 male 2 rx 6 rx 8 rx 2 t x 3 tx 4 tx 7 tx 3 r x 5 gnd 5 gnd 5 gnd 5 gnd mt6050i/mt8050i com1 rs232 9p d - sub fem ale plc rs232 8p rj45 male 9 rx 2 t x 6 tx 3 r x 5 gnd 5 gnd www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 4 the following represents the view of hmi & plc. 9p d - sub to 9p d - sub: plc pl103, pl104, pl105 e mt 3 000 series com1 rs232 9p d - sub f em ale com 3 rs232 9p d - sub fem ale plc rs232 9p d - sub male 2 rx 8 rx 7 t x 3 tx 7 tx 1 r x 5 gnd 5 gnd 5 gnd mt6000 /8000 series except mt6050i/mt8050i com1 rs232 9p d - sub fem ale com2 rs232 9p d - sub fem ale com3 rs232 9p d - sub m ale plc rs232 9p d - sub male 2 rx 6 rx 8 rx 7 t x 3 tx 4 tx 7 tx 1 r x 5 gnd 5 gnd 5 gnd 5 gnd mt6050i/mt8050i com1 rs232 9p d - sub fem ale plc rs232 9p d - sub male 9 rx 7 t x 6 tx 1 r x 5 gnd 5 gnd www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 5 the following represents the view of hmi & plc. 9 p d - sub to 9p d - sub: plc qk800, qk801, qk2000. e mt 3 000 series com1 rs232 9p d - sub fem ale com 3 rs232 9p d - sub fem ale plc rs232 9p d - sub male 2 rx 8 rx 2 t x 3 tx 7 tx 3 r x 5 gnd 5 gnd 7 gnd mt6000 /8000 series except mt6050i/mt8050i com1 rs232 9p d - sub fem ale com2 rs232 9p d - sub fem ale com3 rs232 9p d - sub m ale plc rs232 9p d - sub male 2 rx 6 rx 8 rx 2 t x 3 tx 4 tx 7 tx 3 r x 5 gnd 5 gnd 5 gnd 7 gnd mt6050i/mt8050i com1 rs232 9p d - sub fem ale plc rs232 9p d - sub male 9 rx 2 t x 6 t x 3 r x 5 gnd 7 gnd driver version : version date description v 1.10 jul/24/2009 www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 6 bacnet bacnet/ip supported series : bacnet/ip protocol devices hmi setting : parameters recommended options notes plc type bacnet /ip plc i/f ethernet por t no. 47808 hmi port no. 47808 47808~47823 device id 342566 0~999999 a ccording to device. plc sta. no. 1 bacnet/ip to ms/tp adapter setting: 1. when using bacnet/ip driver, check use [bacnet/ip to ms/tp adapter] to enable this type of communica tion . 2. as shown above, in bacnet/ip to ms/tp adapter mode, [network number] must follow the factory setting, and enter the device station number in [device id ] . 3. [ hmi port no ]. default: 47808 , can be filled in other effective value. www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 7 how to import tags : easybuilder pro provides two ways to gain tag addresses. one is to directly get tag information via internet, another is to export the generated csv file via scada, and then import to easybuilder pro. the following introduces how to import tag addre ss information . step 1. add bacnet/ip driver in system parameters settings step 2. correctly set the relevant parameters. www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 8 step 3. get tag address information way 1: click get tag info . way 2: import the csv file generated by scada software. www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 9 c sv file content is shown below; users can build the file and import: a. object format b. object name (user defined tag name , easybuilder will start reading data from the 6 th row of csv file. ), device id, object type(object id) and instance(object address) ste p 4. file imported successfully. take (10 as an example, 10 represents object id, 2 represents object address, file represents us er defined name or default name. www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 10 default object model : object id object name object structure 0 analog input object name object identifier object type present value event state out of service units min press value max press value cov increment resolution high limit low limit dead band profile name 1 analog output object name object identifier object type present value event state out of service units relinquish default min press value max press value cov increment resolution high limit low limit dead band profile name 2 analog value object name object identifier object type present value event state www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 11 object id object name object structure out of service units relinquis h default cov increment high limit low limit dead band profile name 3 binary input object name object identifier object type present value event state out of service polarity profile name notify type alarm value 4 binary output object name object identif ier object type present value event state out of service polarity profile name notify type 5 binary value object name object identifier object type present value event state out of service profile name notify type alarm value 6 calendar object name objec t identif i er www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 12 object id object name object structure object type present value 7 command object name object identif i er object type present value in process all writes successful 8 device object name object identif i er object type system status vendor name vendor identifier model name firmware r evision application software version protocol version protocol revision max apdu length accepted segmentation supported apdu timeout number of apdu retries data base revision max segments accepted day light savings status apdu segment timeout backup failur e timeout 10 file object name object identif i er object type file type file size archive read only 11 group object name object identifier object type www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 13 object id object name object structure 1 3 multi state input object name object identifier object type present value event state out of service reliability number of states time delay notification class notify type profile name 1 4 multi state output object name object identifier object type present value event state out of service reliability number of states time delay notification class notify type profile name 1 5 notification class object name object identif i er object type notification class priority 1 7 schedule object name object identif i er object type present value priority for writing reliability out of service 1 8 averaging object name ob ject identifier www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 14 object id object name object structure object type minimum value average value maximum value attempted samples valid samples window interval window samples 1 9 multi state value object name object identifier object type present value event state out of service reliability number of states notification class notify type profile name time delay 20 trend log object name object identif i er object type enable stop when full buffer size record count total record count 2 1 lif e safety point object name object identif i er object type pres ent value tracking value event state reliability out of service mode silenced www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 15 object id object name object structure 2 2 lif e safety zone object name object identif i er object type present value tracking value event state reliability o ut of service mode silenced 2 3 accumulator object name objec t identifier object type present value event state out of service scale units reliability 2 4 pulse converter object name object identifier object type present value event state out of service units scale factor adjust value high limit low limit dead band cov increment count note 1. object name can not include # . www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 16 wiring diagram : direct connect (crossover cable): hmi rj45 male wire color wire color plc rj45 male 1 tx+ white/orange white/green 3 rx+ 2 tx - orange green 6 rx - 3 rx+ white/green white/oran ge 1 tx+ 4 bd4+ blue blue 4 bd4+ 5 bd4 - white/blue white/blue 5 bd4 - 6 rx - green orange 2 tx - 7 bd3+ white/brown white/brown 7 bd3+ 8 bd3 - brown brown 8 bd3 - through a hub: hmi rj45 male wire color wire color plc rj45 male 1 tx+ white/orange w hite/orange 1 tx+ 2 tx - orange orange 2 tx - 3 rx+ white/green white/green 3 rx+ 4 bd4+ blue blue 4 bd4+ 5 bd4 - white/blue white/blue 5 bd4 - 6 rx - green green 6 rx - 7 bd3+ white/brown white/brown 7 bd3+ 8 bd3 - brown brown 8 bd3 - driver version : version date description v1.00 jan / 12 /201 2 driver released www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 17 barcode (usb/com) hmi setting: parameters recommend ed option s notes plc type barcode (usb/com) plc i/f rs 232 rs 232/485,usb baud rate 9600 9600 ~115200 data b its 8 7,8 parity none non e, even, odd stop b its 1 1,2 terminator cr/lf cr/lf, stx/etx, other, none device a ddress: bit/word device t ype format range memo b flag dd 0 flag w barcode 0 dd 0 length w barcode 1 dd 1~255 string wiring d iagram: the following represents the v iew of hmi & plc. e mt 3 000 series com1 rs232 9p d - sub fem ale com 3 rs232 9p d - sub fem ale rs232 9p d - sub female 2 rx 8 rx t x d 3 tx 7 tx r x d 5 gnd 5 gnd gnd www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 18 mt6000 /8000 series except mt6050i/mt8050i com1 rs232 9p d - sub fem ale com2 rs232 9p d - sub fem ale com3 rs232 9p d - sub m ale rs232 9p d - sub female 2 rx 6 rx 8 rx t x d 3 tx 4 tx 7 tx r x d 5 gnd 5 gnd 5 gnd gnd mt6050i/mt8050i com1 rs232 9p d - sub fem ale rs232 9p d - sub female 9 rx t x d 6 tx r x d 5 gnd gnd dri ver version : version date description v1. 3 0 oct / 1 / 2010 www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 19 baumuller website: http://www.baumuller.com/ hmi setting: parameters recommend ed option s notes plc type baumuller plc i/f rs485 4w baud rate 19200 9600, 19200 data b its 8 7 or 8 parity even even, odd, none stop b its 1 1 or 2 hmi s t a . n o. 0 plc s t a . n o. 0 defaults plc setting: communication mode rk 512 protocol , 19200 , 8 , 1 , e ven device a ddress: bit/word device t ype format range memo b d b0 _bit ~ db29_bit dddh 0 ~ 255f w db0 ~ db29 ddd 0 ~ 255 www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 20 wiring d iagram: the following represents the view of hmi & plc. e mt 3 000 series com1 rs485 4 w 9p d - sub m ale baumuller servo rs 422 9p d - sub male 1 rx - 1 t xd - 2 r x + 9 txd+ 3 tx - 5 r xd - 4 tx+ 6 rxd+ 5 gnd 8 gnd mt6000 /8000 series except mt6050i/mt8050i com1 rs485 4 w 9p d - sub m ale baumuller servo rs 422 9p d - sub male 1 rx - 1 t xd - 2 r x + 9 txd+ 3 tx - 5 rxd - 4 tx+ 6 rxd+ 5 gnd 8 gnd mt6050i/mt8050i co m1 rs485 4 w 9p d - sub fem ale baumuller servo rs 422 9p d - sub male 1 rx - 1 t xd - 2 r x + 9 txd+ 3 tx - 5 rxd - 4 tx+ 6 rxd+ 5 gnd 8 gnd www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 21 driver version : version date description v1.10 apr/17/2009 www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 22 beckhoff ads/ams (ethernet) support ed s eries: twincat hmi setting: parameters recommend ed option s notes plc type beckhoff ads/ams (ethernet) plc i/f ethernet port n o. 48898 ads port 801 801, 811, 821, 831 plc s t a . n o. 1 plc setting: step1. open twincat system properties . plc settings: s et hmi name , ams net id, and address . ex: hmi ip: 192.168.1.15 ams net id: must input 192.168.1.15.1.1 address: 192.168.1.15 name: input hmi or any user C defined name . www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 23 step2. simulate plc on pc. 2 twincat drivers must be installe d as follows: www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 24 step3. the following commands can be utilized for twincat plc to output the parameters observed. www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 25 ps. twincat plc ix, qx, mx - must output in bool type. iw, qw, mw - must output in uint, word, and int types. id, qd, md - must output in udint, dword, and dint types. project - > rebuild all step4. set plc ip in e asy b uilder . www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 26 step5. click [import tag] button in e asy b uilder to open the tpy file compiled by twincat plc control. step6. download the p rojec t compiled in e asy b uilder to hmi. www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 27 device address : bit/word device type format range memo b ix d ddddo 0 ~ 655357 o : bit no.(0 ~ 7) b qx d ddddo 0 ~ 655357 o : bit no.(0 ~ 7) b mx d ddddo 0 ~ 655357 o : bit no.(0 ~ 7) w iw d d ddd 0 ~ 65535 w qw d d ddd 0 ~ 65535 w mw d d ddd 0 ~ 65535 dw id d d ddd 0 ~ 65535 dw qd d d ddd 0 ~ 65535 dw md d d ddd 0 ~ 65535 wiring d iagram: direct connect (crossover cable): hmi rj45 male wire color wire color plc rj45 male 1 tx+ white/orange white/green 3 rx+ 2 tx - oran ge green 6 rx - 3 rx+ white/green white/orange 1 tx+ 4 bd4+ blue blue 4 bd4+ 5 bd4 - white/blue white/blue 5 bd4 - 6 rx - green orange 2 tx - 7 bd3+ white/brown white/brown 7 bd3+ 8 bd3 - brown brown 8 bd3 - www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 28 through a hub: hmi rj45 male wire color w ire color plc rj45 male 1 tx+ white/orange white/orange 1 tx+ 2 tx - orange orange 2 tx - 3 rx+ white/green white/green 3 rx+ 4 bd4+ blue blue 4 bd4+ 5 bd4 - white/blue white/blue 5 bd4 - 6 rx - green green 6 rx - 7 bd3+ white/brown white/brown 7 bd3+ 8 bd3 - brown brown 8 bd3 - driver version : version date description v1.00 dec/ 08 /2010 driver released. v1.10 aug/24/2011 extended address range up to 65535. www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 29 beckhoff embedded pc supported s eries: intel - cx10x0,cx50x0 and twincat hmi setting: par ameters recommend ed option s notes plc type beckhoff embedded pc plc i/f ethernet port n o. 48898 ads port 801 801, 811, 821, 831 plc s t a . n o. 1 plc setting: for twincat: a. confirm pc ip address www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 30 b. open twincat, set ip address 169.254.56.12.1.1 c. use twincat to build a route t able to make sure the s ystem is connected, if plc power turns off and then on, please redo this step. note: when connected , if x is display ed, the connection succeeded . www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 31 d. open e asybuilder , set ip address, ads port and por t n o . e. run on line simulation. note: if the project is downloaded to hmi, please set hmi ip 169.254.5 6.12 identically to twincat ip address setting. for cerhost : a. execute cerhost.exe to connect with plc on pc. b. enter plc ip and password (default password: 1). www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 32 c. succeeded to connect with plc, click start - > click control panel. d. click [ network and dial - up connections ] to display plc device information; select the plc to check its ip. e. access plc system settings, the default direc tory: \ hard disk \ system , execute [ tcamsremotemgr ]. www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 33 f. ams net id consists of 6 numbers, separated by . . the first 4 numbers stand for ip and followed by 1.1 . the figure below shows the ams n e t id of local computer, please enter plc ip plus 1.1 . re mote computers shows the information of the hmi to connect with. click [add] to add the hmi and click [ok ] to finish setting. g. name: device name. ams net id: the ip followed by 1.1 of the device to connect with. address: the ip address of the devic e to connect with. transport: the way of connection. slow connection: as shown in the figure below. www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 34 h. return to control pan el ; execute cx configuration tool to confirm plc ams net id . i. confirm settings and click start - > reset plc . device add ress : bit/word device type format range memo b ix d ddddo 0 ~ 655357 o : bit no.(0 ~ 7) b qx d ddddo 0 ~ 655357 o : bit no.(0 ~ 7) b mx d ddddo 0 ~ 655357 o : bit no.(0 ~ 7) w iw d d ddd 0 ~ 65535 w qw d d ddd 0 ~ 65535 w mw d d ddd 0 ~ 65535 dw id d d ddd 0 ~ 65535 dw qd d d ddd 0 ~ 65535 dw md d d ddd 0 ~ 65535 www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 35 wiring d iagram: direct connect (crossover cable): hmi rj45 male wire color wire color plc rj45 male 1 tx+ white/orange white/green 3 rx+ 2 tx - orange green 6 rx - 3 rx+ white/green white/orange 1 tx+ 4 bd4+ blue blue 4 bd4+ 5 bd4 - white/blue white/blue 5 bd4 - 6 rx - green orange 2 tx - 7 bd3+ white/brown white/brown 7 bd3+ 8 bd3 - brown brown 8 bd3 - through a hub: hmi rj45 male wire color wire color plc rj45 male 1 tx+ white/orange whit e/orange 1 tx+ 2 tx - orange orange 2 tx - 3 rx+ white/green white/green 3 rx+ 4 bd4+ blue blue 4 bd4+ 5 bd4 - white/blue white/blue 5 bd4 - 6 rx - green green 6 rx - 7 bd3+ white/brown white/brown 7 bd3+ 8 bd3 - brown brown 8 bd3 - driver version : v ersion date description v1.00 apr / 18 /201 1 driver released. v1.10 aug/24/2011 extended address range up to 65535. www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 36 canopen slave (for emt3000 only) emt3000 series only hmi setting : parameters recommended options notes plc type can (controller area ne twork) bus node id 1 1~127 baud rate 250k 10k~1m follow the steps to import eds file. step 1. object dictionary settings - > setting step 2. import eds file. www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 37 step 3. select the eds file to be imported . step 4. successfully import eds file. device address : bit/word device type format range memo b txpdon_bit dddn o 1 0 0 ~ 99977 ddd pdo no. n address (unit byte). o bit no. b rxpdon_bit dd dn o 1 0 0 ~ 99977 ddd pdo no. n address (unit byte). o bit no. b sdo_8bit_bit hhhhhho 0 ~ ffffff7 hhhh(index)+hh(sub - index)+o(bit no) b sdo_16bit_bit hhhhhhdd 0 ~ hhhhhh15 hhhh(index)+hh(sub - inde x)+dd(bit no) w txpdon ddd n 1 0 ~ 999 7 ddd pdo no. n address(unit byte) www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 38 bit/word device type format range memo w txpdon_byte dddn 1 0 ~ 999 7 ddd pdo no. n address(unit byte) w rxpdon ddd n 1 0 ~ 999 7 ddd pdo no. n address(unit byte) w rxpdon_byte dddn 10 ~ 9997 ddd pdo no. n address(unit byte) w sdo_8bit hhhhhh 0~ffffff hhhh(index)+hh(sub - index) w sdo_16 bit hhhhhh 0~ffffff w sdo_32 bit hhhhhh 0~ffffff wiring diagram : the following represents the view of hmi & plc. e mt 3 000 series can bus 9p d - sub fem ale can device 7 d - d - 8 d+ d+ 5 gnd gnd demo project link : driver version : version date description v1. 4 0 aug/20/2012 add device type : sdo_8bit_bit , sdo_16bit_bit. www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 39 change supp orted s eries: compressor controller website: http://www.sh - changjia.com/ hmi setting: parameters recommend ed option s notes plc type change plc i/f rs485 2w baud rate 9600 data b its 8 parity none stop b its 1 plc s t a . n o. 1 1~6 device a ddress: bit/word device t ype format range memo b ctl ddd 0 ~ 5, 128, 150 write only dw set ddd 0 ~ 57, 128 dw status dd 1 ~ 20 read only wiring d iagram: the following represents the view of hmi & plc. e mt 3 000 series co m1 rs485 2 w 9p d - sub m ale com 3 rs485 2 w 9p d - sub m ale change rs 485 terminal 1 rx - 6 data - 15 d - 2 rx+ 9 data+ 16 d+ 5 gnd 5 gnd www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 40 mt6000 /8000 series except mt6050i/mt8050i com1 rs485 2 w 9p d - sub m ale com 3 rs485 2 w 9p d - sub m ale change rs 4 85 terminal 1 rx - 6 data - 15 d - 2 rx+ 9 data+ 16 d+ 5 gnd 5 gnd mt6050i/mt8050i com1 rs485 2 w 9p d - sub fem ale com 3 rs485 2 w 9p d - sub fem ale change rs 485 terminal 1 rx - 7 data - 15 d - 2 rx+ 8 data+ 16 d+ 5 gnd 5 gnd driver v ersion: version date description v1.00 jan/ 19 /2011 driver released . www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 41 cimon cm1 - cp4a /eco1a supported s eries: cimon cm1 series, cp4a module website: http://www.kdtsys.com hmi setting: parameters recommend ed option s notes plc type cimon cm1 - cp4a/eco1a plc i/f rs232 baud rate 38400 data bit s 8 parity none stop bit s 1 plc s t a . n o. 1 device a ddress: bit/word device type format range memo b x ddh 0 ~ 23 f 0 - 1f r ead o nly b y ddh 0 ~ 23 f b m dddh 0 ~ 511 f b k dddh 0 ~ 127 f b l dddh 0 ~ 127f b f dddh 0 ~ 127f read o nly b t dddh 0 ~ 102f b c dddh 0 ~ 102f w d dddd 0 ~ 4999 w s dd 0 ~ 99 max. r ange: 99 w ts dddd 0 ~ 1023 w tc dddd 0 ~ 1023 w cs dddd 0 ~ 1023 w cc dddd 0 ~ 1023 www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 42 wiring d iagram: the following represents the view of hmi & plc. e mt 3 000 series com1 rs232 9p d - sub fem ale com 3 rs232 9p d - sub fem ale cm1 - cp4a rs 232 6 p rj11 male 2 rx 8 rx 2 t xd 3 tx 7 tx 3 r xd 5 gnd 5 gnd 5 gnd mt6000 /8000 series except mt6 050i/mt8050i com1 rs232 9p d - sub fem ale com2 rs232 9p d - sub fem ale com3 rs232 9p d - sub m ale cm1 - cp4a rs 232 6 p rj11 male 2 rx 6 rx 8 rx 2 t xd 3 tx 4 tx 7 tx 3 r xd 5 gnd 5 gnd 5 gnd 5 gnd mt6050i/mt8050i com1 rs232 9p d - sub fem ale cm1 - cp4a rs 2 32 6 p rj11 male 9 rx 2 t xd 6 tx 3 r xd 5 gnd 5 gnd driver version : version date description v1. 2 0 nov/30/2009 www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 43 cimon cm1 - sc02a supported s eries: cimon cm series, sc02a module website: http://www. kdtsys.com hmi setting: parameters recommend ed option s notes plc type cimon cm1 - sc02a plc i/f rs232 baud rate 38400 data bit s 8 parity none stop bit s 1 plc s t a . n o. 1 device a ddress: bit/word device type format range memo b x ddh 0 ~ 23f 0 - 1f r ead o nly b y ddh 0 ~ 23f 0 - f r ead o nly b m dddh 0 ~ 511f b k dddh 0 ~ 127f b l dddh 0 ~ 127f b f dddh 0 ~ 127f read o nly b t dddh 0 ~ 102f b c dddh 0 ~ 102f w d dddd 0 ~ 4999 w s dd 0 ~ 99 max. r ange: 99 w ts dddd 0 ~ 1023 w tc dddd 0 ~ 1023 w cs dddd 0 ~ 1023 w cc dddd 0 ~ 1023 www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 44 wiring d iagram: the following represents the view of hmi & plc. e mt 3 000 series com1 rs232 9p d - sub fem ale com 3 rs232 9p d - sub fem ale cm1 - sc02a rs232 9p d - sub male 2 rx 8 rx 3 t d 3 tx 7 tx 2 r d 5 gnd 5 gnd 5 gnd mt6000 /8000 series except mt6050i/mt8050i com1 rs232 9p d - sub fem ale com2 rs232 9p d - sub fem ale com3 rs232 9p d - sub m ale cm1 - sc02a rs232 9p d - sub male 2 rx 6 rx 8 rx 3 t d 3 tx 4 tx 7 tx 2 r d 5 gnd 5 gnd 5 gnd 5 gnd mt6050i/mt8050i com1 rs232 9p d - sub fem ale cm1 - sc02a rs232 9p d - sub male 9 rx 3 t d 6 tx 2 r d 5 gnd 5 gnd driver version : version date description v1. 2 0 nov/30/2009 www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 45 copley controls supported s eries: digital servo driver & cont rollers , xenus, xenus micro, accelnet, accelnet micro, stepnet series . website: http://www.copleycontrols.com/motion/ hmi setting: parameters recommend ed option s notes plc type copley controls plc i/f rs232 baud rate 9600 9600~115200 data b its 8 8 parity none even, odd, none stop b its 1 1 hmi s t a . n o. 0 plc s t a . n o. 0 0 - 127 device a ddress: bit/word device t ype format range memo w flash int 16 hhh 0 ~ 999 for register is int16 or u 16 w ram int 16 hhh 0 ~ 999 for register is int16 or u16 w flash int 32 hhh 0 ~ 999 for register is int32 or u32 w ram int 32 hhh 0 ~ 999 for register is int32 or u32 w register dddd 0 ~ 2457 w t_command h 0 w reset h 0 www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 46 wiring d iagram: the foll owing represents the view of hmi & plc. 9p d - sub to 6 p rj11 : xenus, xenus micro, accelnet , stepnet e mt 3 000 series com1 rs232 9p d - sub fem ale com 3 rs232 9p d - sub fem ale rs 232 6 p rj11 male 2 rx 8 rx 5 t xd 3 tx 7 tx 2 r xd 5 gnd 5 gnd 3, 4 gnd mt6000 /8000 series except mt6050i/mt8050i com1 rs232 9p d - sub fem ale com2 rs232 9p d - sub fem ale com3 rs232 9p d - sub m ale rs 232 6 p rj11 male 2 rx 6 rx 8 rx 5 t xd 3 tx 4 tx 7 tx 2 r xd 5 gnd 5 gnd 5 gnd 3, 4 gnd mt6050i/mt8050i com1 rs232 9p d - su b fem ale rs 232 6 p rj11 male 9 rx 5 t xd 6 tx 2 r xd 5 gnd 3, 4 gnd www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 47 the following represents the view of hmi & plc. accelnet micro : e mt 3 000 series com1 rs232 9p d - sub fem ale com 3 rs232 9p d - sub fem ale accelnet micro panel rs 232 j5 cable connector 2 rx 8 rx 29 t xd 3 tx 7 tx 14 r xd 5 gnd 5 gnd 15 gnd mt6000 /8000 series except mt6050i/mt8050i com1 rs232 9p d - sub fem ale com2 rs232 9p d - sub fem ale com3 rs232 9p d - sub m ale accelnet micro panel rs 232 j5 cable connector 2 rx 6 rx 8 rx 29 t xd 3 tx 4 tx 7 tx 14 r xd 5 gnd 5 gnd 5 gnd 15 gnd www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 48 mt6050i/mt8050i com1 rs232 9p d - sub fem ale accelnet micro panel rs 232 j5 cable connector 9 rx 29 t xd 6 tx 14 r xd 5 gnd 15 gnd driver version : version date descript ion v1.20 dec/30/2008 www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 49 crouzet m3 (fbd) hmi setting: parameters recommend ed option s notes plc type crouzet m3 (fbd) plc i/f rs232 baud rate 115200 data bit s 7 parity e ven stop bit s 1 plc s t a . n o. 1 device a ddress: bit/word devic e t ype format range memo b sli_bit ddh 1 0 ~ 24 f serial link input b slo_bit ddh 25 0 ~ 48 f serial link output (read only) b state d 1 s tate in plc (read only) w ia dd 1 ~ 99 analogy input (default: 1 ~ 4) w sl_in dd 1 ~ 24 serial link input w sl_out d d 25 ~ 48 serial link output (read only) w time d 1 ~ 6 time & day* w order d 1 c ommand** (write only) * : address 1: second, address 2 : minute, address 3 : hour , address 4 : day, address 5 : month, address 6 : year . the value range for year is 0~99 , entering 0 represents year 2000, entering 99 represents year 2099. **: run mode write 2, stop mode write 1. www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 50 wiring d iagram: the following represents the view of hmi & plc. e mt 3 000 series com1 rs232 9p d - sub fem ale crouzet m3 rs232 9p d - sub male ( extension cable) 2 rx 2 t d 3 tx 3 r d 5 gnd 5 gnd 7 rts 4 dtr mt6000 /8000 series except mt6050i/mt8050i com1 rs232 9p d - sub fem ale crouzet m3 rs232 9p d - sub male (extension cable) 2 rx 2 t d 3 tx 3 r d 5 gnd 5 gnd 7 rts 4 dtr (3m serial link cable) note: please use 3m serial link cable (accessories from millenium 3) and extension cable (as shown ) to communicate with hmi series. www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 51 driver version : version date description v1. 1 0 oct/26/2010 v1.20 mar/29/20 12 add device type : state, time, order v1.30 may/14/2012 time entering is now allowed. www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 52 crouzet m3 (lad) hmi setting: parameters recommend ed option s notes plc type crouzet m3 (lad) plc i/f rs232 baud rate 115200 data bit s 7 parity e ven stop bit s 1 plc s t a . n o. 1 device a ddress: bit/word device t ype format range memo b i dd 1 ~ 99 input (default: 1 ~ 4) b o dd 1 ~ 99 output (default: 1 ~ 4) b m dd 1 ~ 28 relay b sli_bit ddh 1 0 ~ 24 f serial link input b slo_bit ddh 25 0 ~ 48 f serial link output (read only) b state d 1 s tate in plc (read only) w t dd 1 ~ 12 timer w c dd 1 ~ 16 counter w ia dd 1 ~ 99 analogy input (default: 1 ~ 4) w sl_in dd 1 ~ 24 serial link input w sl_out dd 25 ~ 48 serial link output (read only) w tim e d 1 ~ 6 time & day * w order d 1 c ommand (write only) ** * : address 1: second, address 2 : minute, address 3 : hour , address 4 : day, address 5 : month, address 6 : year . the value range for year is 0~99, entering 0 represents year 2000, entering 99 represents year 2099. **: run mode write 2, stop mode write 1. www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 53 wiring d iagram: the following represents the view of hmi & plc. e mt 3 000 series com1 rs232 9p d - sub fem ale crouzet m3 rs232 9p d - sub male (extension cable) 2 rx 2 t d 3 tx 3 r d 5 gnd 5 gnd 7 rts 4 dtr mt6000 /8000 series except mt6050i/mt8050i com1 rs232 9p d - sub fem ale crouzet m3 rs232 9p d - sub male (extension cable) 2 rx 2 t d 3 tx 3 r d 5 gnd 5 gnd 7 rts 4 dtr (3m serial link cable) note: please use 3m serial link cable (accessories from millenium 3) and extension cable (as shown ) to communicate with hmi series. www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 54 driver version : version date description v1.20 oct/26/2010 v1.30 mar/30/2012 add device type : state, time, order v1.40 m ay/14/2012 time entering is now allowed. www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 55 danfoss ecl apex20 website: http://www.danfoss.com/ hmi setting: parameters recommend ed option s notes plc type danfoss ecl apex20 plc i/f rs232 baud rate 9600 data b its 8 parity none stop b its 1 plc s t a . n o. 1 device a ddress: bit/word device t ype format range memo b flag dddd 0 ~ 8191 b output dddd 0 ~ 1023 b input dddd 0 ~ 1023 b reg_bit ddddddd 0 ~ 1638331 dd: bit no. (00 ~ 31) d w registe r dddd d 0 ~ 16383 d w counter dddd 0 ~ 1599 d w timer dddd 0 ~ 1 599 d w reg_float dddd d 0 ~ 16383 support 32 - bit float format e asy b uilder device address range may differ from plc extended mode, please refer to e asy b uilder address range as above. www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 56 wirin g d iagram: the following represents the view of hmi & plc. e mt 3 000 series com1 rs232 9p d - sub fem ale com 3 rs232 9p d - sub fem ale ecl apex20 controller rs232 9p d - sub male 2 rx 8 rx 3 t x d 3 tx 7 tx 2 r x d 5 gnd 5 gnd 5 gnd 7 rts circuit 8 cts mt6000 /8000 series except mt6050i/mt8050i com1 rs232 9p d - sub fem ale com2 rs232 9p d - sub fem ale com3 rs232 9p d - sub m ale ecl apex20 controller rs232 9p d - sub male 2 rx 6 rx 8 rx 3 t x d 3 tx 4 tx 7 tx 2 r x d 5 gnd 5 gnd 5 gnd 5 gnd 7 rts circuit 8 cts mt6050i/mt8050i com1 rs232 9p d - sub fem ale ecl apex20 controller rs232 9p d - sub male 9 rx 3 t x d 6 tx 2 r x d 5 gnd 5 gnd 7 rts circuit 8 cts www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 57 the following represents the view of hmi & plc. e mt 3 000 series com1 rs485 2 w 9p d - sub m ale com 3 rs485 2 w 9p d - sub m ale ecl apex20 controller port#1 / port#0 1 rx - 6 data - 11 / 29 2 rx+ 9 data+ 12 / 28 5 gnd 5 gnd mt6000 /8000 series except mt6050i/mt8050i com1 rs485 2 w 9p d - sub m ale com 3 rs485 2 w 9p d - sub m ale ec l apex20 controller port#1 / port#0 1 rx - 6 data - 11 / 29 2 rx+ 9 data+ 12 / 28 5 gnd 5 gnd mt6050i/mt8050i com1 rs485 2 w 9p d - sub fem ale com 3 rs485 2 w 9p d - sub fem ale ecl apex20 controller port#1 / port#0 1 rx - 7 data - 11 / 29 2 rx+ 8 data+ 12 / 28 5 gnd 5 gnd driver version : version date description v1. 4 0 oct/06/2008 www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 58 danfoss ecl apex20 (ethernet) website: http://www.danfoss.com/ hmi setting: parameters recommend ed option s not es plc type danfoss ecl apex20 (ethernet) plc i/f ethernet port no. 5050 plc s t a . n o. 0 device a ddress: bit/word device t ype format range memo b flag dddd 0 ~ 8191 b output dddd 0 ~ 1023 b input dddd 0 ~ 1023 b reg_bit ddddddd 0 ~ 1638 331 dd: bit no. (00 ~ 31) w register dddd d 0 ~ 16383 w counter dddd 0 ~ 1599 w timer dddd 0 ~ 1 599 w reg_float dddd d 0 ~ 16383 support 32 - bit float format e asy b uilder device address range may differ from plc extended mode, please refer to e asy b uil der address range as above. www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 59 wiring d iagram: direct connect (crossover cable): hmi rj45 male wire color wire color plc rj45 male 1 tx+ white/orange white/green 3 rx+ 2 tx - orange green 6 rx - 3 rx+ white/green white/orange 1 tx+ 4 bd4+ blue blue 4 bd4+ 5 bd4 - white/blue white/blue 5 bd4 - 6 rx - green orange 2 tx - 7 bd3+ white/brown white/brown 7 bd3+ 8 bd3 - brown brown 8 bd3 - through a hub: hmi rj45 male wire color wire color plc rj45 male 1 tx+ white/orange white/orange 1 tx+ 2 tx - orange o range 2 tx - 3 rx+ white/green white/green 3 rx+ 4 bd4+ blue blue 4 bd4+ 5 bd4 - white/blue white/blue 5 bd4 - 6 rx - green green 6 rx - 7 bd3+ white/brown white/brown 7 bd3+ 8 bd3 - brown brown 8 bd3 - driver version : version date description v1. 1 0 jan/10/2011 www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 60 d anfoss fc s eries supported s eries: fc051, fc100, fc200, fc300, vlt micro driver. website: http://www.danfoss.com/ hmi setting: parameters recommend ed option s notes plc type danfoss fc series p lc i/f rs485 2w baud rate 9600 data b its 8 parity even stop b its 1 plc s t a . n o. 1 device a ddress: para_index 310.1=31001, para_index310.0=31000 wiring d iagram: the following represents the view of hmi & plc. e mt 3 000 series com1 rs485 2 w 9p d - sub m ale com 3 rs485 2 w 9p d - sub m ale fc rs 485 terminal 1 r x - 6 data - 69 d - 2 rx+ 9 data+ 68 d+ 5 gnd 5 gnd bit/word device t ype format range memo w parameter 09 ddd d 0 ~ 9999 set parameter d w reference 10 d 0 ~ 1 control bus reference d w par a_index 11 ddd ddd 0 ~ 999999 set parameter(index) www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 61 mt6000 /8000 series except mt6050i/mt8050i com1 rs485 2 w 9p d - sub m ale com 3 rs485 2 w 9p d - sub m ale fc rs 485 terminal 1 rx - 6 data - 69 d - 2 rx+ 9 data+ 68 d+ 5 gnd 5 gnd mt6050i /mt8050i com1 rs485 2 w 9p d - sub fem ale com 3 rs485 2 w 9p d - sub fem ale fc rs 485 terminal 1 rx - 7 data - 69 d - 2 rx+ 8 data+ 68 d+ 5 gnd 5 gnd *rw100 s et pcd1 control word of station 1 *rw101 read pcd1 status word of station 1 *rw102 s et pcd2 control word of station 2 *rw103 read pcd2 status word of station 2 *rw104 s et pcd3 control word of station 3 *rw105 read pcd3 status word of station 3 *rw106 s et pcd4 control word of station 4 *rw107 read pcd4 status word of station 4 driver version : ve rsion date description v1. 1 0 jan/14/2010 www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 62 danfoss vlt2800 series supported s eries: vlt2800 series website: http://www.danfoss.com/ hmi setting: parameters recommend ed option s notes plc type danfoss vlt2800 se ries plc i/f rs485 2w baud rate 9600 data b its 8 parity even stop b its 1 plc s t a . n o. 1 0 - 126 according to plc plc setting: communication mode 9600, even, 8, 1 (default) device a ddress: bit/word device t ype format range memo dw parame ter dddd 0 ~ 2000 set parameter w reference d 0 ~ 1 control bus reference the control word register is set according to the station number. i f the station number is 1, the cont rol word will be rw100 and rw101 ; if the station number is 2, the control wo rd will be rw102 and rw103 , and so on . www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 63 wiring d iagram: the following represents the view of hmi & plc. e mt 3 000 series com1 rs485 2 w 9p d - sub m ale com 3 rs485 2 w 9p d - sub m ale rs485 terminal 1 rx - 6 data - 69 d - 2 rx+ 9 data+ 68 d+ 5 gnd 5 gnd mt6000 /8000 series except mt6050i/mt8050i com1 rs485 2 w 9p d - sub m ale com 3 rs485 2 w 9p d - sub m ale rs485 terminal 1 rx - 6 data - 69 d - 2 rx+ 9 data+ 68 d+ 5 gnd 5 gnd mt6050i/mt8050i com1 rs485 2 w 9p d - sub fem ale com 3 rs485 2 w 9p d - sub f em ale rs485 terminal 1 rx - 7 data - 69 d - 2 rx+ 8 data+ 68 d+ 5 gnd 5 gnd driver version : version date description v1.10 dec / 30 /2008 www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 64 delta dvp supported s eries: delta dvp series website: htt p://www.deltadriver.com hmi setting: parameters recommend ed option s notes plc type delta dvp plc i/f rs232 rs232, rs485 baud rate 9600 9600, 19200 data b its 7 7, 8 parity even even, odd, none stop b its 1 1 plc s t a . n o. 1 0 - 255 device a ddr ess: bit/word device t ype format range memo b x ooooo 0 ~ 23417 ( o ctal) input b y ooooo 0 ~ 23417 ( o ctal) output b m ddddd 0 ~ 65536 auxiliary relay b s dddd 0 ~ 9999 step relay b t dddd 0 ~ 9999 timer b c dddd 0 ~ 9999 counter b tv_bit dddddd 0 ~ 9 99915 timer w tv dddd 0 ~ 9999 timer w cv ddd 0 ~ 127 counter w cv2 ddd 2 00 ~ 25 4 double w ord c ounter w d dddd 0 ~ 9999 data register www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 65 wiring d iagram: the following represents the view of hmi & plc. e mt 3 000 series com1 rs232 9p d - sub fem ale com 3 rs232 9p d - sub fem ale rs232 8p mini - din male 2 rx 8 rx 5 t xd 3 tx 7 tx 4 r xd 5 gnd 5 gnd 3/8 gnd mt6000 /8000 series except mt6050i/mt8050i com1 rs232 9p d - sub fem ale com2 rs232 9p d - sub fem ale com3 rs232 9p d - sub m ale rs232 8p mini - din male 2 r x 6 rx 8 rx 5 t xd 3 tx 4 tx 7 tx 4 r xd 5 gnd 5 gnd 5 gnd 3/8 gnd mt6050i/mt8050i com1 rs232 9p d - sub fem ale rs232 8p mini - din male 9 rx 5 t xd 6 tx 4 r xd 5 gnd 3/8 gnd driver version : version date description v1. 2 0 dec/30/20 08 www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 66 delta dvpen01 - sl (ethernet) website: http://www.deltadriver.com hmi setting: parameters recommend ed option s notes plc type delta dvpen01 - sl (ethernet) plc i/f ethernet port no. 502 plc s t a . n o. 0 device a ddress: bit/word device t ype format range memo b c_bit ddd 0 ~ 255 b m dddd 0 ~ 4095 b s dddd 0 ~ 1023 b t_bit ddd 0 ~ 255 b x ooo 0 ~ 571 b y ooo 0 ~ 571 w c ddd 0 ~ 199 dw c_32bit ddd 200 ~ 255 w d dddd d 0 ~ 11 999 w t dd d 0 ~ 255 www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 67 wiring d iagram: direct connect (crossover cable): hmi rj45 male wire color wire color plc rj45 male 1 tx+ white/orange white/green 3 rx+ 2 tx - orange green 6 rx - 3 rx+ white/green white/orange 1 tx+ 4 bd4+ blue blue 4 bd4+ 5 bd4 - white/b lue white/blue 5 bd4 - 6 rx - green orange 2 tx - 7 bd3+ white/brown white/brown 7 bd3+ 8 bd3 - brown brown 8 bd3 - through a hub: hmi rj45 male wire color wire color plc rj45 male 1 tx+ white/orange white/orange 1 tx+ 2 tx - orange orange 2 tx - 3 r x+ white/green white/green 3 rx+ 4 bd4+ blue blue 4 bd4+ 5 bd4 - white/blue white/blue 5 bd4 - 6 rx - green green 6 rx - 7 bd3+ white/brown white/brown 7 bd3+ 8 bd3 - brown brown 8 bd3 - driver version : version date description v1. 0 0 jun/11/201 2 dri ver released . v1.10 aug/20/2012 add device type : c_32bit. www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 68 dl/t645 chuang hong website: http://www.cw180.com hmi setting: parameters recommend ed option s notes plc type dl/t645 chuang hong plc i/f rs485 2w b aud rate 9600 data b its 8 parity even stop b its 1 plc s t a . n o. 1 device a ddress: bit/word device t ype format range memo w b621 d 0 ~ 1 w b622 d 0 ~ 1 w b623 d 0 ~ 1 w zero phase d 0 ~ 1 w b 611 d 0 ~ 1 w b 612 d 0 ~ 1 w b613 d 0 ~ 1 w b631 d 0 ~ 1 w b632 d 0 ~ 1 w b633 d 0 ~ 1 w b630 d 0 ~ 1 w b641 d 0 ~ 1 w b642 d 0 ~ 1 w b643 d 0 ~ 1 w b640 d 0 ~ 1 w a - apparentt d 0 ~ 1 w b - apparentt d 0 ~ 1 w c - apparentt d 0 ~ 1 w t - apparentt d 0 ~ 1 w b650 d 0 ~ 1 www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 69 bit/word device t ype format range memo w b651 d 0 ~ 1 w b652 d 0 ~ 1 w b653 d 0 ~ 1 w 9010 d 0 ~ 1 w 9020 d 0 ~ 1 w 9110 d 0 ~ 1 w 9120 d 0 ~ 1 w 9130 d 0 ~ 1 w 9140 d 0 ~ 1 w 9150 d 0 ~ 1 w 9160 d 0 ~ 1 w 9410 d 0 ~ 1 w 9420 d 0 ~ 1 w 9510 d 0 ~ 1 w 9520 d 0 ~ 1 w 9530 d 0 ~ 1 w 9540 d 0 ~ 1 w 9550 d 0 ~ 1 w 9560 d 0 ~ 1 w 9810 d 0 ~ 1 w 9820 d 0 ~ 1 w 9910 d 0 ~ 1 w 9920 d 0 ~ 1 w 9930 d 0 ~ 1 w 9940 d 0 ~ 1 w 9950 d 0 ~ 1 w 9960 d 0 ~ 1 w a010 d 0 ~ 1 w a020 d 0 ~ 1 w a110 d 0 ~ 1 w a 120 d 0 ~ 1 w a130 d 0 ~ 1 w a140 d 0 ~ 1 w a150 d 0 ~ 1 w a160 d 0 ~ 1 w a410 d 0 ~ 1 w a420 d 0 ~ 1 w a510 d 0 ~ 1 w a520 d 0 ~ 1 w a530 d 0 ~ 1 www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 70 bit/word device t ype format range memo w a540 d 0 ~ 1 w a550 d 0 ~ 1 w a560 d 0 ~ 1 w a810 d 0 ~ 1 w a820 d 0 ~ 1 w a9 10 d 0 ~ 1 w a920 d 0 ~ 1 w a930 d 0 ~ 1 w a940 d 0 ~ 1 w a950 d 0 ~ 1 w a960 d 0 ~ 1 w b010 d 0 ~ 1 w b020 d 0 ~ 1 w b110 d 0 ~ 1 w b120 d 0 ~ 1 w b130 d 0 ~ 1 w b140 d 0 ~ 1 w b150 d 0 ~ 1 w b160 d 0 ~ 1 w b410 d 0 ~ 1 w b42 0 d 0 ~ 1 w b510 d 0 ~ 1 w b520 d 0 ~ 1 w b530 d 0 ~ 1 w b540 d 0 ~ 1 w b550 d 0 ~ 1 w b560 d 0 ~ 1 w b810 d 0 ~ 1 w b820 d 0 ~ 1 w b910 d 0 ~ 1 w b920 d 0 ~ 1 w b930 d 0 ~ 1 w b940 d 0 ~ 1 w b950 d 0 ~ 1 w b960 d 0 ~ 1 w b210 d 0 ~ 1 w b211 d 0 ~ 1 w b212 d 0 ~ 1 w b213 d 0 ~ 1 w b214 d 0 ~ 1 www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 71 bit/word device t ype format range memo w b310 d 0 ~ 1 w b311 d 0 ~ 1 w b312 d 0 ~ 1 w b313 d 0 ~ 1 w b320 d 0 ~ 1 w b321 d 0 ~ 1 w b322 d 0 ~ 1 w b323 d 0 ~ 1 w b330 d 0 ~ 1 w b331 d 0 ~ 1 w b332 d 0 ~ 1 w b333 d 0 ~ 1 w b340 d 0 ~ 1 w b341 d 0 ~ 1 w b342 d 0 ~ 1 w b343 d 0 ~ 1 w c010 d 0 ~ 1 w c011 d 0 ~ 1 w c020 d 0 ~ 1 w c021 d 0 ~ 1 w c022 d 0 ~ 1 w c030 d 0 ~ 1 w c031 d 0 ~ 1 w c032 d 0 ~ 1 w c033 d 0 ~ 1 w c034 d 0 ~ 1 w c111 d 0 ~ 1 w c112 d 0 ~ 1 w c113 d 0 ~ 1 w c114 d 0 ~ 1 w c115 d 0 ~ 1 w c116 d 0 ~ 1 w c117 d 0 ~ 1 w c118 d 0 ~ 1 w c119 d 0 ~ 1 w c11a d 0 ~ 1 w c211 d 0 ~ 1 w c212 d 0 ~ 1 w c310 d 0 ~ 1 w c311 d 0 ~ 1 www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 72 bit/word device t ype format range memo w c312 d 0 ~ 1 w c313 d 0 ~ 1 w c314 d 0 ~ 1 w c320 d 0 ~ 1 w c321 d 0 ~ 1 w c322 d 0 ~ 1 w c330 d 0 ~ 1 w c331 d 0 ~ 1 w c332 d 0 ~ 1 w c340 d 0 ~ 1 w c341 d 0 ~ 1 w c342 d 0 ~ 1 w c3a0 d 0 ~ 1 w c3a1 d 0 ~ 1 w c3a2 d 0 ~ 1 w c410 d 0 ~ 1 w c411 d 0 ~ 1 w c41e d 0 ~ 1 w c510 d 0 ~ 1 w c511 d 0 ~ 1 w b634 d 0 ~ 1 w b635 d 0 ~ 1 www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 73 wiring d iagram: the following represents the view of hmi & plc. e mt 3 000 series com1 rs485 2 w 9p d - sub m ale com 3 rs485 2 w 9p d - sub m ale rs 485 ter minal 1 rx - 6 data - 13 rs485b1 2 rx+ 9 data+ 12 rs485a1 5 gnd 5 gnd mt6000 /8000 series except mt6050i/mt8050i com1 rs485 2 w 9p d - sub m ale com 3 rs485 2 w 9p d - sub m ale rs 485 terminal 1 rx - 6 data - 13 rs485b1 2 rx+ 9 data+ 12 rs485a1 5 g nd 5 gnd mt6050i/mt8050i com1 rs485 2 w 9p d - sub fem ale com 3 rs485 2 w 9p d - sub fem ale rs 485 terminal 1 rx - 7 data - 13 rs485b1 2 rx+ 8 data+ 12 rs485a1 5 gnd 5 gnd driver version: version date description v1.00 apr/13 /2011 drive r released . www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 74 dl/t645 standard website: http://www.cw180.com hmi setting: parameters recommend ed option s notes plc type dl/t645 standard plc i/f rs485 2w baud rate 9600 data b its 8 parity even stop b it s 1 plc s t a . n o. 1 device a ddress: bit/word device t ype format range memo w data hhhhhhh h 0 ~ 6 ffffff wiring d iagram: the following represents the view of hmi & plc. e mt 3 000 series com1 rs485 2 w 9p d - sub m ale com 3 rs485 2 w 9p d - sub m ale rs 485 t erminal 1 rx - 6 data - d - 2 rx+ 9 data+ d+ 5 gnd 5 gnd www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 75 mt6000 /8000 series except mt6050i/mt8050i com1 rs485 2 w 9p d - sub m ale com 3 rs485 2 w 9p d - sub m ale rs 485 terminal 1 rx - 6 data - d - 2 rx+ 9 data+ d+ 5 gnd 5 gnd mt6050i/ mt8050i com1 rs485 2 w 9p d - sub fem ale com 3 rs485 2 w 9p d - sub fem ale rs 485 terminal 1 rx - 7 data - d - 2 rx+ 8 data+ d+ 5 gnd 5 gnd driver version: version date description v1.00 apr/14/2011 driver released . www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 76 dl - bcm server website: http://www.hzdelin.com hmi setting: parameters recommend ed option s notes plc type dl - bcm server plc i/f rs 232 rs232, rs485 baud rate 9600 9600~115200 data b its 8 8 parity none even, odd, none stop b its 1 1 p lc s t a . n o. 0 0 - 31 device a ddress: bit/word device t ype format range memo b lb dddd 0 ~ 9998 w lw dddd 0 ~ 9998 w rw ddddd 0 ~ 55536 wiring d iagram: the following represents the view of hmi & plc. e mt 3 000 series com1 rs232 9p d - sub fem ale com 3 r s232 9p d - sub fem ale rs232 9p d - sub female 2 rx 8 rx t x d 3 tx 7 tx r x d 5 gnd 5 gnd gnd rts circuit cts www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 77 mt6000 /8000 series except mt6050i/mt8050i com1 rs232 9p d - sub fem ale com2 rs232 9p d - sub fem ale com3 rs232 9p d - sub m ale rs232 9p d - sub female 2 rx 6 rx 8 rx t x d 3 tx 4 tx 7 tx r x d 5 gnd 5 gnd 5 gnd gnd rts circuit cts mt6050i/mt8050i com1 rs232 9p d - sub fem ale rs232 9p d - sub female 9 rx t x d 6 tx r x d 5 gnd gnd rts circuit cts the following represents the view of hmi & plc. e mt 3 000 series com1 rs485 2 w 9p d - sub m ale com 3 rs485 2 w 9p d - sub m ale rs 485 2w 9p d - sub male 1 rx - 6 data - 8 d - 2 rx+ 9 data+ 3 d+ 5 gnd 5 gnd 5 gnd www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 78 mt6000 /8000 series except mt6050i/mt 8050i com1 rs485 2 w 9p d - sub m ale com 3 rs485 2 w 9p d - sub m ale rs 485 2w 9p d - sub male 1 rx - 6 data - 8 d - 2 rx+ 9 data+ 3 d+ 5 gnd 5 gnd 5 gnd mt6050i/mt8050i com1 rs485 2 w 9p d - sub fem ale com 3 rs485 2 w 9p d - sub fem ale rs 485 2w 9p d - sub male 1 rx - 7 data - 8 d - 2 rx+ 8 data+ 3 d+ 5 gnd 5 gnd 5 gnd driver version : version date description v1.00 dec/ 8 /2008 driver released www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 79 emerson charge module website: http://www.emersonnetworkpower.com.cn/pages/default.aspx hmi setting: parameters recommend ed option s notes plc type emerson charge module plc i/f rs - 232 baud rate 9600 data bits 8 parity odd stop bits 1 plc s t a . n o. 1 device address : bit/word device type format range memo b float_point_forced d 0 ~ 1 b average_point_forced d 0 ~ 1 w switch_status d 0 ~ 1 w manual_status d 0 ~ 1 w protect_status d 0 ~ 1 w failure_status d 0 ~ 1 w preset_voltage d 0 ~ 1 w preset_percent d 0 ~ 1 w output_voltage d 0 ~ 1 w output_current d 0 ~ 1 w high_limit d 0 ~ 1 w low_limit d 0 ~ 1 w float_point_setting d 0 ~ 1 w average_point_setting d 0 ~ 1 www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 80 wiring diagram: the following represents the view of hmi & plc. e mt 3 000 series com1 rs232 9p d - sub fem ale com 3 rs232 9p d - sub fem ale rs232 terminal 2 rx 8 rx t x d 3 tx 7 tx r x d 5 gnd 5 gnd gnd mt6000 /8000 series except mt6050i/mt8050i com1 rs232 9p d - sub fem ale com2 rs232 9p d - sub fem ale com3 rs232 9p d - sub m ale rs2 32 terminal 2 rx 6 rx 8 rx t x d 3 tx 4 tx 7 tx r x d 5 gnd 5 gnd 5 gnd gnd mt6050i/mt8050i com1 rs232 9p d - sub fem ale rs232 terminal 9 rx t x d 6 tx r x d 5 gnd gnd driver version : version date description v 1.00 mar/3/2009 www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 81 emerson plc ec20 support ed s eries: emerson plc ec20 series. (modbus rtu protocol) hmi setting: parameters recommend ed option s notes plc type emerson plc ec20 plc i/f rs232 baud rate 9600 9600, 19200, 115200 data b its 8 7 or 8 parity even even , odd, none stop b its 1 1 or 2 plc s t a . n o. 0 0 - 255 plc setting: communication mode modbus rtu protocol device a ddress: bit/word device t ype format range memo b y ooo 0 ~ 377 0000 - 025 5 0 b x ooo 0 ~ 377 1200 - 01455 0000 - 0255 b m dddd 0 ~ 1999 20 00 - 3999 b sm ddd 0 ~ 255 4400 - 4655 b s ddd 0 ~ 991 6000 - 6991 b t ddd 0 ~ 255 8000 - 8255 b c ddd 0 ~ 255 9200 - 9455 w d dddd 0 ~ 7999 0000 - 7999 w sd ddd 0 ~ 255 8000 - 8255 w z dd 0 ~ 15 8500 - 8515 w t ddd 0 ~ 255 9000 - 9255 w c ddd 0 ~ 199 9500 - 9699 dw c_double ddd 200 ~ 255 9700 - 9811 dw d_double dddd 0 ~ 7998 0000 - 7999 www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 82 wiring d iagram: the following represents the view of hmi & plc. e mt 3 000 series com1 rs232 9p d - sub fem ale com 3 rs232 9p d - sub fem ale emerson ec20 com1 terminal 2 rx 8 rx t xd 3 tx 7 tx r xd 5 gnd 5 gnd gnd mt6000 /8000 series except mt6050i/mt8050i com1 rs232 9p d - sub fem ale com2 rs232 9p d - sub fem ale com3 rs232 9p d - sub m ale emerson ec20 com1 terminal 2 rx 6 rx 8 rx t xd 3 tx 4 tx 7 tx r xd 5 gnd 5 gnd 5 gnd gnd mt6050i/mt8050i com1 rs232 9p d - sub fem ale emerson ec20 com1 terminal 9 rx t xd 6 tx r xd 5 gnd gnd driver version : version date description v1.10 dec/30/2008 www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 83 fatek fb s eries supported s eries: fatek fbs series, fb mc series , and fb ma series need fb - dtbr converter. website: http://www.fatek.com/ hmi setting: parameters recommend ed option s notes plc type fatek fb series plc i/f rs232 rs232/rs485 /ethernet baud rate 9600 data b its 7 parity even stop b its 1 plc s t a . n o. 1 0 - 255 must match plc port setting. tcp port no. 500 ethernet only. device a ddress: bit/word device t ype format range memo b x dddd 0 ~ 9999 input b y dddd 0 ~ 9999 output b m dddd 0 ~ 9999 internal relay b s dddd 0 ~ 9999 step relay b t dddd 0 ~ 9999 timer b c dddd 0 ~ 9999 counter b plc_mode d 0 plc mode b r_bit dddddd 0 ~ 999915 b d_bit dddddd 0 ~ 999915 w rt dddd 0 ~ 9999 timer register w rc dddd 0 ~ 9999 counter register w r dddd 0 ~ 9 999 data register w d dddd 0 ~ 9999 data register w drt dddd 0 ~ 9999 double w ord timer register w drc ddd 20 0 ~ 255 double w ord counter register w wx dddd 0 ~ 9999 input w ord w wy dddd 0 ~ 9999 output w ord www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 84 bit/word device t ype format range memo w wm dddd 0 ~ 9999 internal relay w ord w w s dddd 0 ~ 9999 w fr dddd 0 ~ 9999 wiring d iagram: the following represents the view of hmi & plc. 9p d - sub to 4 p m ini - din : fbs port0 e mt 3 000 series com1 rs232 9p d - sub fem ale com 3 rs232 9p d - sub fem ale fbs rs232 4 p m ini - din male 2 rx 8 rx 3 t x 3 tx 7 tx 4 r x 5 gnd 5 gnd 2 gnd mt6000 /8000 series except mt6050i/mt8050i com1 rs232 9p d - sub fem ale com2 rs232 9p d - sub fem ale com3 rs232 9p d - sub m ale fbs rs232 4 p m ini - din male 2 rx 6 rx 8 rx 3 t x 3 tx 4 tx 7 tx 4 r x 5 gnd 5 gnd 5 gnd 2 gn d mt6050i/mt8050i com1 rs232 9p d - sub fem ale fbs rs232 4 p m ini - din male 9 rx 3 t x 6 tx 4 r x 5 gnd 2 gnd www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 85 the following represents the view of hmi & plc. 9p d - sub to 9p d - sub: fbs communication module e mt 3 000 series com1 rs232 9p d - sub fem ale com 3 rs232 9p d - sub fem ale fbs communication module rs232 9p d - sub male 2 rx 8 rx 2 t x 3 tx 7 tx 3 r x 5 gnd 5 gnd 5 gnd mt6000 /8000 series except mt6050i/mt8050i com1 rs232 9p d - sub fem ale com2 rs232 9p d - sub fem ale com3 rs2 32 9p d - sub m ale fbs communication module rs232 9p d - sub male 2 rx 6 rx 8 rx 2 t x 3 tx 4 tx 7 tx 3 r x 5 gnd 5 gnd 5 gnd 5 gnd mt6050i/mt8050i com1 rs232 9p d - sub fem ale fbs communication module rs232 9p d - sub male 9 rx 2 t x 6 tx 3 r x 5 gnd 5 gnd www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 86 the following represents the view of hmi & plc. fbs communication module 3 p terminal block e mt 3 000 series com1 rs485 2 w 9p d - sub m ale com 3 rs485 2 w 9p d - sub m ale fbs communication module 3 p terminal 1 rx - 6 data - d - 2 rx+ 9 dat a+ d+ 5 gnd 5 gnd mt6000 /8000 series except mt6050i/mt8050i com1 rs485 2 w 9p d - sub m ale com 3 rs485 2 w 9p d - sub m ale fbs communication module 3 p terminal 1 rx - 6 data - d - 2 rx+ 9 data+ d+ 5 gnd 5 gnd mt6050i/mt8050i com1 rs485 2 w 9p d - sub fem ale com 3 rs485 2 w 9p d - sub fem ale fbs communication module 3 p terminal 1 rx - 7 data - d - 2 rx+ 8 data+ d+ 5 gnd 5 gnd www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 87 the following represents the view of hmi & plc. 9p d - sub to 15 p d - sub: cpu port e mt 3 000 series com1 rs2 32 9p d - sub fem ale com 3 rs232 9p d - sub fem ale fb cpu port rs232 15 p d - sub male 2 rx 8 rx 2 t x 3 tx 7 tx 1 r x 5 gnd 5 gnd 6 gnd 3 rts circuit 4 cts mt6000 /8000 series except mt6050i/mt8050i com1 rs232 9p d - sub fem ale com2 rs232 9p d - sub fem ale com3 rs232 9p d - sub m ale fb cpu port rs232 15 p d - sub male 2 rx 6 rx 8 rx 2 t x 3 tx 4 tx 7 tx 1 r x 5 gnd 5 gnd 5 gnd 6 gnd 3 rts circuit 4 cts mt6050i/mt8050i com1 rs232 9p d - sub fem ale fb cpu port rs232 15 p d - sub male 9 rx 2 t x 6 tx 1 r x 5 gnd 6 gnd 3 rts circuit 4 cts www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 88 the following represents the view of hmi & plc. 9p d - sub to 15 p d - sub: cpu port rs485 2w e mt 3 000 series com1 rs485 2 w 9p d - sub m ale com 3 rs485 2 w 9p d - sub m ale fb cpu port rs 485 2w 15 p d - sub male 1 rx - 6 data - 7 d - 2 rx+ 9 data+ 5 d+ 5 gnd 5 gnd mt6000 /8000 series except mt6050i/mt8050i com1 rs485 2 w 9p d - sub m ale com 3 rs485 2 w 9p d - sub m ale fb cpu port rs 485 2w 15 p d - sub male 1 rx - 6 data - 7 d - 2 rx+ 9 data+ 5 d+ 5 g nd 5 gnd mt6050i/mt8050i com1 rs485 2 w 9p d - sub fem ale com 3 rs485 2 w 9p d - sub fem ale fb cpu port rs 485 2w 15 p d - sub male 1 rx - 7 data - 7 d - 2 rx+ 8 data+ 5 d+ 5 gnd 5 gnd driver version : version date description v1. 6 0 feb / 17 /2 01 1 r_bit, d_bit and ws address types are added. v1.70 nov/29/2011 f r address types are added. www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 89 fuji nb series website: http://www.fujielectric.co.jp/fcs/eng/ hmi setting: parameters recommend ed option s notes plc type fuji nb series plc i/f rs485 4w baud rate 19200 data bits 8 parity odd stop bits 1 plc s t a . n o. 0 plc setting: communication mode nitp p rotocol / plc password (default is 0) device a ddress: bit/word device t ype format range memo b y hhh 0 ~ 7ff output relay b x hhh 0 ~ 3ff input relay b m hhh 0 ~ fff internal relay b l hhh 0 ~ fff latch relay b c hh 0 - ff counter b m_spe hhhh 0 ~ 81ff special relay b t hhh 0 ~ 1ff timer w tv hhh 0 ~ 3ff timer value w cv hhh 0 ~ 3ff counter value w d hhhh 0 ~ 1fff data register w d_spe hhhh 0 ~ 81ff special register www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 90 wiring d iagram: the following represents the view of hmi & plc. e mt 3 000 series com1 rs485 4 w 9p d - sub m ale fuji nb series rs 422 8 p rj4 5 male 1 rx - 4 t x - 2 r x + 3 tx+ 3 tx - 6 rx - 4 tx+ 5 rx+ 5 gnd mt6000 /8000 series except mt6050i/mt8050i com1 rs485 4 w 9p d - sub m ale fuji nb series rs 422 8 p rj45 male 1 rx - 4 t x - 2 r x + 3 tx+ 3 tx - 6 rx - 4 tx+ 5 rx+ 5 gn d mt6050i/mt8050i com1 rs485 4 w 9p d - sub fem ale fuji nb series rs 422 8 p rj45 male 1 rx - 4 t x - 2 r x + 3 tx+ 3 tx - 6 rx - 4 tx+ 5 rx+ 5 gnd www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 91 driver version : version date description v1.10 may/05/2009 www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 92 ge f anuc 0i md w ebsite: http://www.fanucfa.com/welcome_worldwide/ hmi setting: parameters recommend ed option s notes plc type ge f anuc 0i md plc i/f rs232 baud rate 19200 data b its 8 parity even st op b its 1 plc s t a . n o. 0 on - line s imulat ion yes plc setting: reader/puncher interface (2ch.) is used for touch panel i nterface. external touch panel interface, s/n: a02b - 0320 - j685, for power mate series. device a ddress: bit/word device t ype forma t range memo b x dddd o 0 ~ 11277 b y dddd o 0 ~ 11277 b k ddd o 0 ~ 9997 b e ddd do 0 ~ 99997 b d_bit ddd do 0 ~ 99997 b r_bit ddd do 0 ~ 94997 w t ddd d 0 ~ 9499 m ust be a multiple of 2 w c ddd d 0 ~ 5199 m ust be a multiple of 4 w d_byte dddd 0 ~ 9999 w r_byte dddd 0 ~ 9499 w d ddd d 0 ~ 9999 m ust be a multiple of 2 w r dddd 0 ~ 9499 m ust be a multiple of 2 www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 93 wiring d iagram: the following represents the view of hmi & plc. e mt 3 000 series com1 rs232 9p d - sub fem ale com 3 rs232 9p d - sub fem ale rs2 32 20 p jd36b or jd54 female 2 rx 8 rx 11 tx 3 tx 7 tx 1 rx 5 gnd 5 gnd 8 (jd36) 4(jd54) gnd 15 rts circuit 05 cts 03 dr circuit 07 cd 13 er mt6000 /8000 series except mt6050i/mt8050i com1 rs232 9p d - sub fem ale com2 rs232 9p d - sub fem ale com3 rs232 9p d - sub m ale rs232 20 p jd36b or jd54 female 2 rx 6 rx 8 rx 11 tx 3 tx 4 tx 7 tx 1 rx 5 gnd 5 gnd 5 gnd 8(jd36) 4(jd54) gnd 15 rts circuit 05 cts 03 dr circuit 07 cd 13 er www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 94 mt6050i/mt8050i com1 rs232 9p d - s ub fem ale rs232 20 p jd36b or jd54 female 9 rx 11 tx 6 tx 1 rx 5 gnd 8(jd36) 4(jd54) gnd 15 rts circuit 05 cts 03 dr circuit 07 cd 13 er driver version : version date description v1.00 may/16 /2011 driver released . www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 95 ge fan uc cmm website: http://www. ge. com hmi setting: parameters recommend ed option s notes plc type ge fanuc cmm plc i/f rs232 rs232/rs485 baud rate 19200 9600,19200,38400,5 7600,115200 data b its 8 7,8 must set to 8 for t his protocol parity odd even, odd, none stop b its 1 1, 2 plc s t a . n o. 0 0 - 255 does not apply to this protocol plc setting: refer to the related plc manual . device a ddress: bit/word device t ype format range memo b i ddddd 1 ~ 1000 0 input relay b q ddddd 1 ~ 1000 0 output relay b m ddddd 1 ~ 1000 0 auxiliary relay b g dddd 1 ~ 7680 b t ddd 1 ~ 256 b sa ddd 1 ~ 128 b sb ddd 1 ~ 128 b sc ddd 1 ~ 128 b s ddd 1 ~ 128 w ai ddddd 1 ~ 1000 0 analog input register w aq ddddd 1 ~ 1000 0 analog out put register w r ddddd 1 ~ 32640 data register www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 96 wiring d iagram: the following represents the view of hmi & plc. cpu p ort 90 - 30/versamax emt3000 series com1 rs485 4 w 9p d - sub m ale 90 - 30/versamax rs485 4w 15p d - sub male 1 rx - 12 sda 2 rx+ 13 sdb 5 gnd 7 gnd 3 tx - 10 rda 4 tx+ 11 rdb circuit 9 rt 6 rtsa circuit 15 ctsa 8 rtsb circuit 14 ctsb mt6000 /8000 series except mt6050i/mt8050i com1 rs485 4 w 9p d - sub m ale 90 - 30/versamax rs485 4w 15p d - sub male 1 rx - 12 sda 2 rx+ 13 sdb 5 gnd 7 gnd 3 tx - 10 rda 4 tx+ 11 rdb circuit 9 rt 6 rtsa circuit 15 ctsa 8 rtsb circuit 14 ctsb www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 97 mt6050i/mt8050i com1 rs485 4 w 9p d - sub fem ale 90 - 30/versamax rs485 4w 15p d - sub male 1 rx - 12 sda 2 rx+ 13 sdb 5 gnd 7 gnd 3 tx - 10 rda 4 tx+ 11 rdb circuit 9 rt 6 rtsa circuit 15 ctsa 8 rtsb circuit 14 ctsb the following represents the view of hmi & plc. cpu p ort (90 - 30 series cpu351/352/363/364) emt300 0 series com1 rs232 9p d - sub fem ale com 3 rs232 9p d - sub fem ale 90 - 30/90 - 70 series rs232 6 p rj 11 male 2 rx 8 rx 2 tx 3 tx 7 tx 5 rx 5 gnd 5 gnd 3 gnd mt6000 /8000 series except mt6050i/mt8050i com1 rs232 9p d - sub fem ale com2 rs232 9p d - sub fe m ale com3 rs232 9p d - sub m ale 90 - 30/90 - 70 series rs232 6 p rj 11 male 2 rx 6 rx 8 rx 2 tx 3 tx 4 tx 7 tx 5 rx 5 gnd 5 gnd 5 gnd 3 gnd www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 98 mt6050i/mt8050i com1 rs232 9p d - sub fem ale 90 - 30/90 - 70 series rs232 6 p rj 11 male 9 rx 2 tx 6 tx 5 rx 5 gnd 3 gnd the following represents the view of hmi & plc. cpu p ort (versamax series cpu001/002/005/e05) e mt 3 000 series com1 rs232 9p d - sub fem ale com 3 rs232 9p d - sub fem ale versamax series rs232 9p d - sub male 2 rx 8 rx 2 t x 3 tx 7 tx 3 r x 5 gnd 5 gnd 5 gnd mt6000 /8000 series except mt6050i/mt8050i com1 rs232 9p d - sub fem ale com2 rs232 9p d - sub fem ale com3 rs232 9p d - sub m ale versamax series rs232 9p d - sub male 2 rx 6 rx 8 rx 2 t x 3 tx 4 tx 7 tx 3 r x 5 gnd 5 gnd 5 gnd 5 gnd www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 99 mt6050i/mt8050i com1 rs232 9p d - sub fem ale versamax series rs232 9p d - sub male 9 rx 2 t x 6 tx 3 r x 5 gnd 5 gnd driver version : version date description v1.00 jul/09/2009 driver released . www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 100 ge f anuc rx3i website: http://www.ge.com hmi setting: parameters recommend ed option s notes plc type ge f anuc rx3i plc i/f rs232 rs232, rs485 baud rate 19200 1200~115200 data bit s 8 parity odd none, even, odd stop bit s 1 1 or 2 plc s t a . n o. 1 1~99 plc setting: refer to the related plc manual . device a ddress: bit/word device type format range memo b i ddddd 1 ~ 32768 b q ddddd 1 ~ 32768 b m ddddd 1 ~ 32768 b g ddddd 1 ~ 32768 b t ddddd 1 ~ 32768 b sa ddddd 1 ~ 32768 b sb ddddd 1 ~ 32768 b sc ddddd 1 ~ 32768 b s ddddd 1 ~ 32768 w ai ddddd 1 ~ 32768 w aq ddddd 1 ~ 32768 w r ddddd 1 ~ 32768 www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 101 wiring d iagram: the following represents the view of hmi & plc. e mt 3 000 series com1 rs232 9p d - sub fem ale com 3 rs232 9p d - sub f em ale ge fanuc rx3i com1 rs232 9p d - sub male 2 rx 8 rx 2 t x d 3 tx 7 tx 3 r x d 5 gnd 5 gnd 5 gnd mt6000 /8000 series except mt6050i/mt8050i com1 rs232 9p d - sub fem ale com2 rs232 9p d - sub fem ale com3 rs232 9p d - sub m ale ge fanuc rx3i com1 rs232 9p d - sub male 2 rx 6 rx 8 rx 2 t x d 3 tx 4 tx 7 tx 3 r x d 5 gnd 5 gnd 5 gnd 5 gnd mt6050i/mt8050i com1 rs232 9p d - sub fem ale ge fanuc rx3i com1 rs232 9p d - sub male 9 rx 2 t x d 6 tx 3 r x d 5 gnd 5 gnd www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 102 the following represents the view of hmi & plc. ge fanuc rx3i com2 emt3000 series com1 rs485 4 w 9p d - sub m ale ge fanuc rx3i com2 rs232 15 p d - sub male 1 rx - 12 sda 2 rx+ 13 sdb 5 gnd 7 gnd 3 tx - 10 rda 4 tx+ 11 rdb circuit 9 rt 6 rtsa circuit 15 ctsa 8 rtsb circuit 14 ctsb mt6000 /8000 series except mt6050i/mt8050i com1 rs485 4 w 9p d - sub m ale ge fanuc rx3i com2 rs232 15 p d - sub male 1 rx - 12 sda 2 rx+ 13 sdb 5 gnd 7 gnd 3 tx - 10 rda 4 tx+ 11 rdb circuit 9 rt 6 rtsa ci rcuit 15 ctsa 8 rtsb circuit 14 ctsb www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 103 mt6050i/mt8050i com1 rs485 4 w 9p d - sub fem ale ge fanuc rx3i com2 rs232 15 p d - sub male 1 rx - 12 sda 2 rx+ 13 sdb 5 gnd 7 gnd 3 tx - 10 rda 4 tx+ 11 rdb circuit 9 rt 6 rtsa circu it 15 ctsa 8 rtsb circuit 14 ctsb driver version : version date description v1. 1 0 oct/ 0 1/2010 driver released . www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 104 ge fanuc s eries 90 - 30 (ethernet) supported s eries: ge 90 - 30 series, cpu model 374plus . hmi setting: parameters recommend ed option s notes plc type ge fanuc series 90 - 30 (ethernet) plc i/f ethernet port n o. 18245 plc s t a . n o. 1 1~99 device a ddress: bit/word device type format range memo b i_bit ddddd 1 ~ 32768 b q_bit ddddd 1 ~ 32768 b m_bit ddddd 1 ~ 32768 b g_bit ddddd 1 ~ 32768 b t_bit ddddd 1 ~ 32768 b sa_bit ddddd 1 ~ 32768 read only b sb_bit ddddd 1 ~ 32768 read only b sc_bit ddddd 1 ~ 32768 read only b s_bit ddddd 1 ~ 32768 read only b r_bit ddddd 1 ~ 32768 w i ddddd 1 ~ 327 53 address incre ment by 8 words, ex: i1, i9, i17, i25.. w q ddddd 1 ~ 32753 t he rule is same as above, ex:q1, q9, q17 w m ddddd 1 ~ 32753 t he rule is same as above, ex:m1, m9, m17.. w g ddddd 1 ~ 32753 t he rule is same as above, ex:g1, g9, g17 w t dddd 1 ~ 1024 t he rul e is same as above, ex:t1, t9, t17. w sa ddddd 1 ~ 32753 read o nly, the rule is same as above w sb ddddd 1 ~ 32753 read o nly, the rule is same as above www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 105 bit/word device type format range memo w sc ddddd 1 ~ 32753 read o nly, the rule is same as above w s ddddd 1 ~ 32753 read o nly, the rule i s same as above w r ddddd 1 ~ 32768 w ai ddddd 1 ~ 32768 w aq ddddd 1 ~ 32768 w w ddddddd 1 ~ 5000000 wiring d iagram: direct connect (crossover cable): hmi rj45 male wire color wire color plc rj45 male 1 tx+ white/orange white/green 3 rx+ 2 tx - orange green 6 rx - 3 rx+ white/green white/orange 1 tx+ 4 bd4+ blue blue 4 bd4+ 5 bd4 - white/blue white/blue 5 bd4 - 6 rx - green orange 2 tx - 7 bd3+ white/brown white/brown 7 bd3+ 8 bd3 - brown brown 8 bd3 - through a hub: hmi rj45 male wire col or wire color plc rj45 male 1 tx+ white/orange white/orange 1 tx+ 2 tx - orange orange 2 tx - 3 rx+ white/green white/green 3 rx+ 4 bd4+ blue blue 4 bd4+ 5 bd4 - white/blue white/blue 5 bd4 - 6 rx - green green 6 rx - 7 bd3+ white/brown white/brown 7 bd3+ 8 bd3 - brown brown 8 bd3 - www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 106 driver version : version date description v1. 70 apr/09/2010 v1.80 nov/09/2011 add device type : r_bit v1.90 jan/17/2012 add device type : w www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 107 ge fanuc snp - x supported s eries: ge fanuc 90 & versamax series plc website : http://www. ge. com hmi setting: parameters recommend ed option s notes plc type ge fanuc snp - x plc i/f rs485 4 w rs232/rs485 baud rate 19200 9600, 19200, 38400, 57600, 115200 data b its 8 7, 8 must set to 8 for this p rotocol parity odd even, odd, none stop b its 1 1, 2 plc s t a . n o. 0 0 - 255 does not apply to this protocol plc setting: refer to the related plc manual . device a ddress: bit/word device t ype format range memo b i ddddd 1 ~ 1000 0 input relay b q dddd d 1 ~ 1000 0 output relay b m ddddd 1 ~ 1000 0 auxiliary relay b g dddd 1 ~ 7680 b t ddd 1 ~ 256 b sa ddd 1 ~ 128 b sb ddd 1 ~ 128 b sc ddd 1 ~ 128 b s ddd 1 ~ 128 w ai ddddd 1 ~ 1000 0 analog input register w aq ddddd 1 ~ 1000 0 analog output r egister w r ddddd 1 ~ 32640 data register www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 108 wiring d iagram: the following represents the view of hmi & plc. cpu p ort (90 - 30/versamax) e mt 3 000 series com1 rs485 4 w 9p d - sub m ale 90 - 30/versamax rs 422 15 p d - sub male 1 rx - 12 sda 2 rx+ 13 sdb 5 gnd 7 gnd 3 tx - 10 rda 4 tx+ 11 rdb circuit 9 rt 6 rtsa circuit 15 ctsa 8 rtsb circuit 14 ctsb mt6000 /8000 series except mt6050i/mt8050i com1 rs485 4 w 9p d - sub m ale 90 - 30/versamax rs 422 15 p d - sub male 1 rx - 12 sda 2 rx+ 13 sdb 5 gnd 7 gnd 3 tx - 10 rda 4 tx+ 11 rdb circuit 9 rt 6 rtsa circuit 15 ctsa 8 rtsb circuit 14 ctsb www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 109 mt6050i/mt8050i com1 rs485 4 w 9p d - sub fem ale 90 - 30/versamax rs 422 15 p d - sub male 1 rx - 12 sda 2 rx+ 13 sdb 5 gnd 7 gnd 3 tx - 10 rda 4 tx+ 11 rdb circuit 9 rt 6 rtsa circuit 15 ctsa 8 rtsb circuit 14 ctsb the following represents the view of hmi & plc. cpu p ort (90 - 30 series cpu351/352/363/364) emt3000 series com1 rs232 9p d - su b fem ale com 3 rs232 9p d - sub fem ale 90 - 30/90 - 70 series rs232 6 p rj 11 male 2 rx 8 rx 2 tx 3 tx 7 tx 5 rx 5 gnd 5 gnd 3 gnd mt6000 /8000 series excepts mt6050i/mt8050i com1 rs232 9p d - sub fem ale com2 rs232 9p d - sub fem ale com3 rs232 9p d - sub m ale 90 - 30/90 - 70 series rs232 6 p rj 11 male 2 rx 6 rx 8 rx 2 tx 3 tx 4 tx 7 tx 5 rx 5 gnd 5 gnd 5 gnd 3 gnd www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 110 mt6050i/mt8050i com1 rs232 9p d - sub fem ale 90 - 30/90 - 70 series rs232 6 p rj 11 male 9 rx 2 tx 6 tx 5 rx 5 gnd 3 gnd th e following represents the view of hmi & plc. cpu p ort (versamax series cpu001/002/005/e05) e mt 3 000 series com1 rs232 9p d - sub fem ale com 3 rs232 9p d - sub fem ale versamax series rs232 9p d - sub male 2 rx 8 rx 2 t x 3 tx 7 tx 3 r x 5 gnd 5 gnd 5 gnd mt6000 /8000 series except mt6050i/mt8050i com1 rs232 9p d - sub fem ale com2 rs232 9p d - sub fem ale com3 rs232 9p d - sub m ale versamax series rs232 9p d - sub male 2 rx 6 rx 8 rx 2 t x 3 tx 4 tx 7 tx 3 r x 5 gnd 5 gnd 5 gnd 5 gnd www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 111 mt6050i/mt8050i com1 rs232 9p d - sub fem ale versamax series rs232 9p d - sub male 9 rx 2 t x 6 tx 3 r x 5 gnd 5 gnd driver version : version date description v1.20 jan/09/2009 www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 112 haiwell plc support series: e series, s series and h series. web: http://www.haiwell.com/ hmi setting: parameters recommend ed option s notes plc type haiwell plc plc i/f rs232 rs232,rs485 2w baud rate 19200 19200 data bits 8 8 parity none none stop bits 2 2 plc s t a . n o. 1 1~247 device a ddress: bit/word device t ype format range memo b x dddd 0 ~ 1023 input switch b y dddd 0 ~ 1023 output switch b m ddddd 0 ~ 1 2287 internal relay b t dddd 0 ~ 1023 timer (output coil state) b c ddd 0 ~ 255 timer (output coil state) b sm dd d 0 ~ 215 system status bit b s dddd 0 ~ 2047 step bit w cr dd 0 ~ 79 special module parameter register w ai ddd 0 ~ 255 analog input register w aq ddd 0 ~ 255 analog output register w v ddddd 0 ~ 1 4847 data register w tcv dddd 0 ~ 1023 timer (curren t value register) w ccv ddd 0 ~ 255 timer (current value register) w sv ddd 0 ~ 1 54 system register www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 113 wiring d iagram: the following represents the view of hmi & plc. e mt 3 000 series com1 rs232 9p d - sub fem ale com 3 rs232 9p d - sub fem ale rs232 4 p m ini - din male 2 rx 8 rx 2 t x 3 tx 7 tx 1 r x 5 gnd 5 gnd 3 gnd mt6000 /8000 series except mt6050i/mt8050i com1 rs232 9p d - sub fem ale com2 rs232 9p d - sub fem ale com3 rs232 9p d - sub m ale rs232 4 p m ini - din male 2 rx 6 rx 8 rx 2 t x 3 tx 4 tx 7 tx 1 r x 5 gnd 5 gnd 5 gnd 3 gnd mt6050i/mt8050i com1 rs232 9p d - sub fem ale rs232 4 p m ini - din male 9 rx 2 t x 6 tx 1 r x 5 gnd 3 gnd www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 114 e mt 3 000 series com1 rs485 2 w 9p d - sub m ale com 3 rs485 2 w 9p d - sub m ale rs485 2w terminal 1 rx - 6 data - b - data+ 2 rx+ 9 data+ a+ data - 5 gnd 5 gnd mt6000 /8000 series except mt6050i/mt8050i com1 rs485 2 w 9p d - sub m ale com 3 rs485 2 w 9p d - sub m ale rs485 2w terminal 1 rx - 6 data - b - data+ 2 rx+ 9 data+ a+ data - 5 gnd 5 gnd mt6050i/mt8050i com1 rs485 2 w 9p d - sub fem ale com 3 rs485 2 w 9p d - sub fem ale rs485 2w terminal 1 rx - 7 data - b - data+ 2 rx+ 8 data+ a+ data - 5 gnd 5 gnd driver version : version date description v1. 0 0 mar/2/2012 d river released. www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 115 hangz hou maiou mo - tech support series: ls glofa series gm3, gm4, gm6, gm7 cpu port . website: http://www.lgis.com/ hmi setting: parameters recommend ed option s notes plc type hangzhou maiou mo - tech plc i/f rs 232 baud r ate 9600 data b its 8 parity none stop b its 1 plc s t a . n o. 1 device a ddress: bit/word device t ype format range memo b mwx ddddd 0 ~ 25515 b b mwx_no_rps ddddd 0 ~ 25515 b w mw ddd 0 ~ 255 w w mw_no_rps ddd 0 ~ 255 w wiring d iagram: the following represents the view of hmi & plc. e mt 3 000 series com1 rs232 9p d - sub fem ale com 3 rs232 9p d - sub fem ale rs232 terminal 2 rx 8 rx t d 3 tx 7 tx r d 5 gnd 5 gnd gnd www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 116 mt6000 /8000 series except mt6050i/mt8050i com1 rs232 9p d - sub fem al e com2 rs232 9p d - sub fem ale com3 rs232 9p d - sub m ale rs232 terminal 2 rx 6 rx 8 rx t d 3 tx 4 tx 7 tx r d 5 gnd 5 gnd 5 gnd gnd mt6050i/mt8050i com1 rs232 9p d - sub fem ale rs232 terminal 9 rx t d 6 tx r d 5 gnd gnd driver versi on : version date description v1. 0 0 apr/27/2010 www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 117 hanyoung controller supported s eries: temperature controller . website: http://hynux.com/kor/ hmi setting : parameters recommen ded option s notes plc type hanyoung c ontroller plc i/f rs485 4w baud rate 9600 data b its 8 7 or 8 parity none even, odd, none stop b its 1 1 or 2 plc s t a . n o. 1 0 - 255 * in system parameter settings / device settings / com settings, set parameter 1 to 1 to support check sum mo de. www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 118 device a ddress: bit/word device t ype format range memo b i dddd 1 ~ 9999 w d dddd 1 ~ 9999 wiring d iagram: the following represents the view of hmi & plc. e mt 3 000 series com1 rs485 4 w 9p d - sub m ale han young rs 422 terminal 1 rx - 32 t x - 2 r x + 31 tx+ 3 tx - 34 rx - 4 tx+ 33 rx+ 5 gnd mt6000 /8000 series except mt6050i/mt8050i com1 rs485 4 w 9p d - sub m ale han young rs 422 terminal 1 rx - 32 t x - 2 r x + 31 tx+ 3 tx - 34 rx - 4 tx+ 33 rx+ 5 gnd www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 119 mt6050i/mt80 50i com1 rs485 4 w 9p d - sub fem ale han young rs 422 terminal 1 rx - 32 t x - 2 r x + 31 tx+ 3 tx - 34 rx - 4 tx+ 33 rx+ 5 gnd driver version : version date description v1. 60 jun/14/2010 www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 120 hawe plvc supported s eries: hawe plvc website: http://www.hawe.de/de/home/ hmi setting: parameters recommend ed option s notes plc type hawe plvc plc i/f rs 232 baud rate 9600 data b its 8 parity none stop b its 1 plc s t a . n o. 0 device a d dress: bit/word device t ype format range memo b x hhhh 0 ~ ffff input bits b y hhhh 0 ~ ffff output bits b m ddddd 0 ~ 65535 internal relays b t ddddd 0 ~ 65535 b c ddddd 0 ~ 65535 b b hhhh 0 ~ ffff b f ddddd 0 ~ 65535 w tv ddddd 0 ~ 65535 time r preset value w cv ddddd 0 ~ 65535 counter preset value w d ddddd 0 ~ 65535 data registers w w hhhh 0 ~ ffff w r ddddd 0 ~ 65535 www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 121 wiring d iagram: the following represents the view of hmi & plc. e mt 3 000 series com1 rs232 9p d - sub fem ale com 3 rs232 9p d - sub fem ale rs 232 terminal 2 rx 8 rx t x d 3 tx 7 tx r x d 5 gnd 5 gnd gnd mt6000 /8000 series except mt6050i/mt8050i com1 rs232 9p d - sub fem ale com2 rs232 9p d - sub fem ale com3 rs232 9p d - sub m ale rs 232 terminal 2 rx 6 rx 8 rx t x d 3 tx 4 t x 7 tx r x d 5 gnd 5 gnd 5 gnd gnd mt6050i/mt8050i com1 rs232 9p d - sub fem ale rs 232 terminal 9 rx t x d 6 tx r x d 5 gnd gnd driver version : version date description v1. 0 0 sep/17/2009 www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 122 heng yuan eu series supported s eries : eu ser eis , eu5 series , eu10 series . w ebsite : http://www.tjhysensor.cn/ hmi setting : parameters recommend ed option s notes plc type heng yuan eu series plc i/f rs 485 2w baud rate 9600 data b its 8 parity even stop b its 1 plc s t a . n o. 2 1 - 31 online s imulator yes extend a ddress mode yes device a ddress: bit/word device t ype format range memo w parameter dddd 0 ~ 2000 wiring d iagram: the following represents the view of hmi & plc. e mt 3 000 series com1 rs485 2 w 9p d - sub m ale com 3 rs485 2 w 9p d - sub m ale heng yuan sensor rs 485 1 rx - 6 data - 7 rx - (yellow) 2 rx+ 9 data+ 6 rx+ (green) 5 gnd 5 gnd 4 gnd (black) www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 123 mt6000 /8000 series except mt6050i/mt8050i com1 rs485 2 w 9p d - sub m ale com 3 r s485 2 w 9p d - sub m ale heng yuan sensor rs 485 1 rx - 6 data - 7 rx - (yellow) 2 rx+ 9 data+ 6 rx+ (green) 5 gnd 5 gnd 4 gnd (black) mt6050i/mt8050i com1 rs485 2 w 9p d - sub fem ale com 3 rs485 2 w 9p d - sub fem ale heng yuan sensor rs 485 1 rx - 7 dat a - 7 rx - (yellow) 2 rx+ 8 data+ 6 rx+ (green) 5 gnd 5 gnd 4 gnd (black) driver version : version date description v1.00 dec/30/2008 d river released. www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 124 h itachi eh - sio hmi setting: parameters recommend ed option s notes plc type hitachi eh - sio plc i/f rs232 rs232, rs485 baud rate 19200 9600, 19200, 38400 data b its 7 7 parity even even stop b its 1 1 plc s t a . n o. 0 plc setting: communication mode 19200, e, 7, 1 (default) device a ddress: bit/word device t ype format range memo b x hhhhh 0 ~ ffff f external i nput - bit (x) b y hhhhh 0 ~ ffff f external o utput - bit (y) b m hhhhh 0 ~ ffff f data area - bit (m) b t hhhhh 0 ~ ffff f timer (t) b r hhhhh 0 ~ ffff f internal o utput (r) b l hhhhh 0 ~ ffff f link area - bit (l) w tc hh 0 ~ ff timer/counter current value w wm hhhh 0 ~ 270 f data area - word (m) w wx hhhh 0 ~ 270 f external i nput - word (x) w wy hhhh 0 ~ 270 f external o utput - word (y) w wr hhhh 0 ~ 270 f internal o utput - word (r) w wl hhhh 0 ~ 270 f link area - word (l) www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 125 wiring d iagram: the following represents the view of hmi & plc. eh - sio port1/port 2 rs232 emt3000 series com1 rs232 9p d - sub fem ale com 3 rs232 9p d - sub fem ale rs232 8p rj45 male 2 rx 8 rx 5 sd 3 tx 7 tx 6 rd 5 gnd 5 gnd 1 sg 8 cts 8 rs 4 phl circuit 7 dr mt6000 /8000 series except mt6050i/mt8050i com1 rs232 9p d - sub fem ale com2 rs232 9p d - sub fem ale com3 rs232 9p d - sub m ale rs232 8p rj45 male 2 rx 6 rx 8 rx 5 sd 3 tx 4 tx 7 tx 6 rd 5 gnd 5 gnd 5 gnd 1 sg 8 cts 8 rs 4 phl circuit 7 dr www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 126 mt6050i/mt8050i com1 rs232 9p d - sub fem ale rs232 8p rj45 male 9 rx 5 sd 6 tx 6 rd 5 gnd 1 sg 8 rs 4 phl circuit 7 dr the following represents the view of hmi & plc. eh - sio port 2 rs485 4 w e mt 3 000 series com1 rs485 4 w 9p d - sub m ale hitachi eh - sio 1 rx - 2 tx - 2 r x + 1 tx+ 3 tx - 4 rx - 4 tx+ 3 rx+ 5 gnd 6 sg mt6000 /8000 series except mt6050i/mt8050i com1 rs485 4 w 9p d - sub m ale hitachi eh - sio 1 rx - 2 tx - 2 r x + 1 tx+ 3 tx - 4 rx - 4 tx+ 3 rx+ 5 gnd 6 sg www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 127 mt6050i/mt8050i com1 rs485 4 w 9p d - sub fem ale hitachi eh - sio 1 rx - 2 tx - 2 r x + 1 tx+ 3 tx - 4 rx - 4 tx+ 3 rx+ 5 gnd 6 sg the following represents the view of hmi & plc. eh - sio port 2 rs485 2w e mt 3 000 series com1 rs485 2 w 9p d - sub m ale com 3 rs485 2 w 9p d - sub m ale hitachi eh - sio 1 rx - 6 data - 2 tx - circuit 4 rx - 2 rx+ 9 data+ 1 tx+ circuit 3 rx+ 5 gnd 5 gnd 6 sg mt6000 /8000 series except mt6050i/mt8050i com1 rs485 2 w 9p d - sub m ale co m 3 rs485 2 w 9p d - sub m ale hitachi eh - sio 1 rx - 6 data - 2 tx - circuit 4 rx - 2 rx+ 9 data+ 1 tx+ circuit 3 rx+ 5 gnd 5 gnd 6 sg www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 128 mt6050i/mt8050i com1 rs485 2 w 9p d - sub fem ale com 3 rs485 2 w 9p d - sub fem ale hitachi eh - sio 1 rx - 7 data - 2 tx - circuit 4 rx - 2 rx+ 8 data+ 1 tx+ circuit 3 rx+ 5 gnd 5 gnd 6 sg driver version : version date description v1.00 may/25/2010 d river released. www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 129 hitachi ehv series (ethernet) website: http://www.hitachi - ies.co.jp/english/products/plc/index.htm hmi setting: parameters r ecommend ed option s notes plc type hitachi ehv series (ethernet) plc i/f ethernet port n o. 3004 3004~3007 device a ddress : bit/wor d device type format range memo b x hhhhh 0 ~ fffff external i nput - bit (x) b y hhhhh 0 ~ fffff external o utput - bit (y) b m hhhhh 0 ~ fffff data area - bit (m) b t ddddd 0 ~ 65535 timer (t) b r hhhhh 0 ~ fffff internal o utput (r) b l hhhhh 0 ~ fffff lin k area - bit (l) w tc dddd 0 ~ 2559 timer/counter current value w wm hhhh 0 ~ 7fff data area - word (m) w wx hhhh 0 ~ ffff external input - word (x) w wy hhhh 0 ~ ffff external o utput - word (y) w wr hhhh 0 ~ ffff internal o utput - word (r) w wl hhhh 0 ~ 73 ff link area - word (l) www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 130 wiring d iagram: direct connect (crossover cable): hmi rj45 male wire color wire color plc rj45 male 1 tx+ white/orange white/green 3 rx+ 2 tx - orange green 6 rx - 3 rx+ white/green white/orange 1 tx+ 4 bd4+ blue blue 4 bd4+ 5 b d4 - white/blue white/blue 5 bd4 - 6 rx - green orange 2 tx - 7 bd3+ white/brown white/brown 7 bd3+ 8 bd3 - brown brown 8 bd3 - through a hub: hmi rj45 male wire color wire color plc rj45 male 1 tx+ white/orange white/orange 1 tx+ 2 tx - orange orange 2 tx - 3 rx+ white/green white/green 3 rx+ 4 bd4+ blue blue 4 bd4+ 5 bd4 - white/blue white/blue 5 bd4 - 6 rx - green green 6 rx - 7 bd3+ white/brown white/brown 7 bd3+ 8 bd3 - brown brown 8 bd3 - driver version : version date description v1.00 jan/ 12/2010 driver released www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 131 hitachi h/eh/ehv series supported s eries: h itachi h series , eh - 150, micro - eh, h20, h40, h64, h200, h250, h252, h300, h302, h700, h702, h1000, h1002, h2000, h4010 . website: http://www.hitachi - ies.co.jp/english/products/plc/index.htm hmi setting : parameters recommend ed option s notes plc type hitachi h/eh/ehv series plc i/f rs232 rs232, rs485 baud rate 19200 9600, 19200, 38400 data b its 7 7 parity even even stop b its 1 1 plc s t a . n o. 0 0 - 255 does not apply to this protocol. online s imulator yes broadcast command no extend address mode no device a ddress: bit/word device t ype format range memo b x hhhhh 0 ~ fffff external i nput - bit (x) b y hhhhh 0 ~ fffff external o utput - bit (y) b m hhhhh 0 ~ fffff data area - bit (m) b t hhhhh 0 ~ fffff timer (t) b r hhhhh 0 ~ fffff internal o utput (r) b l hhhhh 0 ~ fffff link area - bit (l) w tc hh 0 ~ ff timer/counter current value w wm hhhh 0 ~ 270 f data area - word (m) w wx hhhh 0 ~ 270 f external i nput - word (x) w wy hhhh 0 ~ 270 f external o utput - word (y) w wr hhhh 0 ~ c3ff internal o utput - word (r) w wl hhhh 0 ~ 270f link area - word (l) www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 1 32 wiring d iagram: warning: if your communication cable is not wi red exactly as shown in our cable assembly instructions, damage to the hmi or loss of co mmunications can be caused . switch number 1 off normal mode 2 off trns0 operation 3, 4 3 4 port1 transmission speed on on 4,800 bps doesnt support off on 9,600 bps on off 19,200 bps default off off 38,400 bps 5 on dedicated port 6 6 phl port2 transmission speed on low 9,600 bps on high 38,400 bps off low 4,800 bps doesnt support off high 19,200 bps default 7 off (system mode) do not turn on. 8 off (system mode) do not turn on. cpu type port 1 port 2 eh - 150/cpu 104a rs - 232 rs - 232 eh - 150/cpu 208a rs - 232 rs - 232 eh - 150/cpu 308a rs - 232/rs - 485 rs - 232 eh - 150/cpu 316a rs - 232/rs - 485 rs - 232 eh - 150/cpu 448a rs - 232/rs - 485 rs - 232 port 1 port 2 toggle - switch phl low phl high www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 133 the following represents the view of hmi & plc. eh - 150 port1/port 2 rs232 / micro - eh port1 rs232 e mt 3 000 series com1 rs232 9p d - sub fem ale com 3 rs232 9p d - sub fem ale r s232 8p rj45 male 2 rx 8 rx 5 sd 3 tx 7 tx 6 rd 5 gnd 5 gnd 1 sg 8 cts 8 rs 4 phl circuit 7 dr mt6000 /8000 series except mt6050i/mt8050i com1 rs232 9p d - sub fem ale com2 rs232 9p d - sub fem ale com3 rs232 9p d - sub m ale r s232 8p rj45 male 2 rx 6 rx 8 rx 5 sd 3 tx 4 tx 7 tx 6 rd 5 gnd 5 gnd 5 gnd 1 sg 8 cts 8 rs 4 p hl circuit 7 dr mt6050i/mt8050i com1 rs232 9p d - sub fem ale r s232 8p rj45 male 9 rx 5 sd 6 tx 6 rd 5 gnd 1 sg 8 rs 4 phl circuit 7 dr www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 134 the following represents the view of hmi & plc. eh - 150 port 1 rs485 4 w e mt 3 000 serie s com1 rs485 4 w 9p d - sub m ale rs485 4w 8p rj45 male 1 rx - 5 tx - 2 r x + 4 tx+ 3 tx - 6 rx - 4 tx+ 7 rx+ 5 gnd 1 sg mt6000 /8000 series except mt6050i/mt8050i com1 rs485 4 w 9p d - sub m ale rs485 4w 8p rj45 male 1 rx - 5 tx - 2 r x + 4 tx+ 3 tx - 6 rx - 4 tx+ 7 rx+ 5 gnd 1 sg mt6050i/mt8050i com1 rs485 4 w 9p d - sub fem ale rs485 4w 8p rj45 male 1 rx - 5 tx - 2 r x + 4 tx+ 3 tx - 6 rx - 4 tx+ 7 rx+ 5 gnd 1 sg www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 135 the following represents the view of hmi & plc . eh - 150 port 1 rs485 2w e mt 3 000 series com1 rs485 2 w 9p d - sub m ale com 3 rs485 2 w 9p d - sub m ale rs485 2w 8p rj45 male 1 rx - 6 data - 4 tx+ circuit 7 rx+ 2 rx+ 9 data+ 5 tx - circuit 6 rx - 5 gnd 5 gnd 1 sg mt6000 /8000 series except mt6050i /mt8050i com1 rs485 2 w 9p d - sub m ale com 3 rs485 2 w 9p d - sub m ale rs485 2w 8p rj45 male 1 rx - 6 data - 4 tx+ circuit 7 rx+ 2 rx+ 9 data+ 5 tx - circuit 6 rx - 5 gnd 5 gnd 1 sg mt6050i/mt8050i com1 rs485 2 w 9p d - sub fem ale com 3 rs485 2 w 9p d - sub fem ale rs485 2w 8p rj45 male 1 rx - 7 data - 4 tx+ circuit 7 rx+ 2 rx+ 8 data+ 5 tx - circuit 6 rx - 5 gnd 5 gnd 1 sg www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 136 the following represents the view of hmi & plc. h series cpu port rs232 emt3000 series com1 rs232 9p d - sub fem ale com 3 rs232 9p d - sub fem ale rs232 15p d - sub male 2 rx 8 rx 2 tx d 3 tx 7 tx 3 rx d 5 gnd 5 gnd 9 s g circuit 10 sg 8 cts 4 rts 5 cts circuit 7 dsr 8 phl 14 pv12 mt6000 /8000 series except mt6050i/mt8050i com1 rs232 9p d - sub fem ale com2 rs232 9p d - sub fem ale com3 rs232 9p d - sub m ale rs232 15p d - sub male 2 rx 6 rx 8 rx 2 tx d 3 tx 4 tx 7 tx 3 rx d 5 gnd 5 gnd 5 gnd 9 s g circuit 10 sg 8 cts 4 rts 5 cts circuit 7 dsr 8 phl 14 pv12 www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 137 mt60 50i/mt8050i com1 rs232 9p d - sub fem ale rs232 15p d - sub male 9 rx 5 sd 6 tx 6 rd 5 gnd 1 sg circuit 8 rs 5 cts circuit 7 dsr 8 phl 14 pv12 driver version : version date description v1.10 oct/22/2009 fixed hmi occup ies the c ontrol right of cpu module . v1. 3 0 mar / 22 /20 10 www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 138 hust h4x supported s eries: hust cnc controller h4 series . website: http://www.hust.com.tw/ hmi setting: parameters recommend ed option s notes plc type hust h4x pl c i/f rs - 232 cpu port baud rate 38400 9600,19200,38400,57600 data bits 7 parity even stop bits 2 turn around delay 5 plc s t a . n o. 1 device a ddress: bit/word device t ype format range memo b i ddd 0 ~ 255 mapping to vm 10800 ~ 10807 (re ad only) b o ddd 0 ~ 255 mapping to vm 10808 ~ 10815 (read only) b c ddd 0 ~ 255 mapping to vm 10816 ~ 10823 (read only) b s ddd 0 ~ 255 mapping to vm 10824 ~ 10831 (read only) b a ddd 0 ~ 255 mapping to vm 10832 ~ 10863 (read only) b vm_bit ddddddd 1 00 ~ 99999 31 bit address (dd): 00 ~ 31 dw vm ddddd 1 ~ 99999 p lease refer to the c ontroller specification for register range. dw r ddd 0 ~ 255 mapping to vm 10000 ~ 10255 (read only) dw cn ddd 0 ~ 255 mapping to vm 10256 ~ 10511 (read only) dw tm ddd 0 ~ 255 mapping to vm 10512 ~ 10767 (read only) www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 139 wiring d iagram: the following represents the view of hmi & plc. e mt 3 000 series com1 rs232 9p d - sub fem ale com 3 rs232 9p d - sub fem ale hust cnc controller rs232 d - sub m ale 2 rx 8 rx 2 t x d 3 tx 7 tx 3 r x d 5 gnd 5 gnd 5 gnd mt6000 /8000 series except mt6050i/mt8050i com1 rs232 9p d - sub fem ale com2 rs232 9p d - sub fem ale com3 rs232 9p d - sub m ale hust cnc controller rs232 d - sub m ale 2 rx 6 rx 8 rx 2 t x d 3 tx 4 tx 7 tx 3 r x d 5 gnd 5 gnd 5 gnd 5 gnd mt6050i/mt8050i com1 rs232 9p d - sub fem ale hust cnc controller rs232 d - sub m ale 9 rx 2 t x d 6 tx 3 r x d 5 gnd 5 gnd driver version : version date description v 2.01 sep/29/2009 www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 140 i ai x - sel controller website: http://www.iai - robot.co.jp/ hmi setting: parameters recommend ed option s notes plc type iai x - sel controller plc i/f rs 232 baud rate 9600 9600 ~ 19200 data b its 7 7 or 8 parity none even, odd, none stop b its 1 1 or 2 plc s t a . n o. 0 device a ddress: bit/word device t ype format range memo w servo_on_off h 1 ~ 8 address 1~8 represent the corresponding axis. write 1 means on and 0 means off. w servo_origin h 1 ~ 8 address 1~8 represent the corresponding axis. back to origin. w currentaxispos h 1 ~ 8 for reading current position. the state of current axis is put in rw axis*100. i.e., for the state of axis 2, 2*100=200, so it is in rw200. w runprogram h 0 data written indicates which program to run. w endpro gram h 0 data written indicates which program to stop. w pointmove h 0 ~ 8 address 1~8 represent the corresponding axis. the data written indicates which point to reach. put parameters acc, dec, speed in axis*100+1, axis*100+2 and axis*100+3 respectively. www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 141 bit/word device t ype format range memo w joggingmove h 0 ~ 8 jogging. address 1~8 represent the corresponding axis. put parameters acc, dec, speed and position in axis*100+11, axis*100+12, axis*100+13 and axis*100+14 respectively. w absolutemove h 0 ~ 8 jog to the set absolute coordinate. ad dress 1~8 represent the corresponding axis. put parameters acc, dec, speed and position in axis*100+21, axis*100+22, axis*100+23 and axis*100+24 respectively. w pointchange h 0 ~ 8 to change the value of the point. address 1~8 represent the corresponding axis. put parameters acc, dec, speed and position in axis*100+31, axis*100+32, axis*100+33 and axis*100+34 respectively. w softwarereset h 0 reset soft ware. note: ddd: decimal, hhh: hexadecimal, ooo: octal. each model of c pu is different; it is recommen ded to refer to plc m anual device list. wiring d iagram: the following represents the view of hmi & plc. e mt 3 000 series com1 rs232 9p d - sub fem ale com 3 rs232 9p d - sub fem ale host rs232 d - sub fem ale 2 rx 8 rx 3 tx 3 tx 7 tx 2 rx 5 gnd 5 gnd 5 gnd www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 142 mt6000 /8000 series except mt6050i/mt8050i com1 rs232 9p d - sub fem ale com2 rs232 9p d - sub fem ale com3 rs232 9p d - sub m ale host rs232 d - sub fem ale 2 rx 6 rx 8 rx 3 tx 3 tx 4 tx 7 tx 2 rx 5 gnd 5 gnd 5 gnd 5 gnd mt6050i/mt8050i com1 rs232 9p d - sub fem ale host rs232 d - sub fem ale 9 rx 3 tx 6 tx 2 rx 5 gnd 5 gnd driver version : version date description v1.00 jun/01/2010 driver released . www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 143 idec micro supported s eries: idec micro3, micro3c, microsmart, opennet co ntroller series . website: http://www.idec.com hmi setting: parameters recommend ed option s notes plc type idec micro plc i/f rs232 rs232, rs485 baud rate 9600 9600, 19200 data b its 7 7, 8 parity even even, odd , none stop b its 1 1 plc s t a . n o. 255 (for 1:1 connect) 0 - 255 255 or same as the plc setting online s imulator yes extend address mode yes do not set the plc station no. to 255 plc setting: communication mode 9600, e, 7, 1 (default), use computer link protocol device a ddress: bit/word device t ype format range memo b x ddddo 0 ~ 2047 7 input (i) b y ddddo 0 ~ 2047 7 output (q) b m ddddo 0 ~ 2047 7 internal relay (m) w rt dddd 0 ~ 9999 timer (t) w rc dddd 0 ~ 9999 counter (c) w d dddd 0 ~ 9999 data register (d) www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 144 wiring d iagram: the following represents the view of hmi & plc. micro3c, microsmart, opennet controller cpu ladder port e mt 3 000 series com1 rs232 9p d - sub fem ale com 3 rs232 9p d - sub fem ale port1 or port2 rs232 8p m ini - din male 2 rx 8 rx 3 t xd 3 tx 7 tx 4 r xd 5 gnd 5 gnd 7 gnd mt6000 /8000 series except mt6050i/mt8050i com1 rs232 9p d - sub fem ale com2 rs232 9p d - sub fem ale com3 rs232 9p d - sub m ale port1 or port2 rs232 8p m ini - din male 2 rx 6 rx 8 rx 3 t xd 3 tx 4 tx 7 tx 4 r xd 5 gnd 5 gnd 5 gnd 7 gnd mt6050i/mt8050i com1 rs232 9p d - sub fem ale port1 or port2 rs232 8p m ini - din male 9 rx 3 t xd 6 tx 4 r xd 5 gnd 7 gnd www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 145 the following represents the view of hmi & plc. micro3 cpu port, microsmart with fc4a - pc2 rs485 communication adapter e mt 3 000 series com1 rs485 2 w 9p d - sub m ale com 3 rs485 2 w 9p d - sub m ale rs 485 8 p mini - din male 1 rx - 6 data - 2 rxd - 2 rx+ 9 data+ 1 rxd+ 5 gnd 5 gnd 7 gnd mt6000 /8000 series except mt6050i/mt8050i com1 r s485 2 w 9p d - sub m ale com 3 rs485 2 w 9p d - sub m ale rs 485 8 p mini - din male 1 rx - 6 data - 2 rxd - 2 rx+ 9 data+ 1 rxd+ 5 gnd 5 gnd 7 gnd mt6050i/mt8050i com1 rs485 2 w 9p d - sub fem ale com 3 rs485 2 w 9p d - sub fem ale rs 485 8 p mini - din male 1 rx - 7 data - 2 rxd - 2 rx+ 8 data+ 1 rxd+ 5 gnd 5 gnd 7 gnd www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 146 the following represents the view of hmi & plc. micro3c, opennet controller data link terminals,microsmart with fc4a - pc3 rs485 communication adapter e mt 3 000 series com1 rs485 2 w 9p d - sub m ale com 3 rs485 2 w 9p d - sub m ale data link terminal 1 rx - 6 data - a rxd - 2 rx+ 9 data+ b rxd+ 5 gnd 5 gnd sg gnd mt6000 /8000 series except mt6050i/mt8050i com1 rs485 2 w 9p d - sub m ale com 3 rs485 2 w 9p d - sub m ale data link terminal 1 rx - 6 data - a rxd - 2 rx+ 9 data+ b rxd+ 5 gnd 5 gnd sg gnd mt6050i/mt8050i com1 rs485 2 w 9p d - sub fem ale com 3 rs485 2 w 9p d - sub fem ale data link terminal 1 rx - 7 data - a rxd - 2 rx+ 8 data+ b rxd+ 5 gnd 5 gnd sg gnd driver ve rsion : version date description v1.20 jun/19/2009 www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 147 inovance h2u/h1u website: http://www.inovance.cn/ hmi setting: parameters recommend ed option s notes plc type inovance h2u/h1u plc i/f rs485 4w baud rate 96 00 9600 ~ 19200 data b its 7 7 or 8 parity even even, odd, none stop b its 1 1 or 2 plc s t a . n o. 0 device a ddress: bit/word device t ype format range memo b x ooo 0 ~ 377 input bits b y ooo 0 ~ 377 output bits b m dddd 0 ~ 7999 auxiliary relay b t ddd 0 ~ 255 timer relay b c ddd 0 ~ 255 counter relay b sm dddd 8000 ~ 9999 special auxiliary relay b d_bit dddddd 0 ~ 799915 b s dddd 0 ~ 4095 w tv ddd 0 ~ 255 timer memory w cv ddd 0 ~ 199 counter memory w d dddd 0 ~ 7999 data registers d w c v 2 ddd 200 ~ 255 counter memory (32bit) w sd dddd 8000 ~ 9999 special data register note: ddd: decimal, hhh: hexadecimal, ooo: octal. e ach model of cpu is different, it is recommended to refer to plc m anual device list. www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 148 wiring d iagram: the following re presents the view of hmi & plc. e mt 3 000 series com1 rs485 4 w 9p d - sub m ale h2u/h1u rs422 8p mini - din male 1 rx - 4 tx - 2 r x + 7 tx+ 3 tx - 1 rx - 4 tx+ 2 rx+ 5 gnd 3 gnd mt6000 /8000 series except mt6050i/mt8050i com1 rs485 4 w 9p d - sub m ale h2u/h1u rs422 8p mini - din male 1 rx - 4 tx - 2 r x + 7 tx+ 3 tx - 1 rx - 4 tx+ 2 rx+ 5 gnd 3 gnd mt6050i/mt8050i com1 rs485 4 w 9p d - sub fem ale h2u/h1u rs422 8p mini - din male 1 rx - 4 tx - 2 r x + 7 tx+ 3 tx - 1 rx - 4 tx+ 2 rx+ 5 gnd 3 gnd www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 149 driver version : version date description v1.00 ma y /19/2010 driver released . www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 150 justfi controller supported s eries: justfi weighing instruments , industrial batching controller supports xk31cb4, xk31cb6. website: http://www.justfi.com hmi setting: parameters recommend ed option s notes plc type justfi controller plc i/f rs232 baud rate 9600 9600, 19200 data b its 7 7 or 8 parity even even, odd, none stop b its 1 1 or 2 plc s t a . n o. 1 device a ddress: bit/word device t ype format range memo w func dd 0 ~ 99 read / write d w func_dw dd 0 ~ 99 read / write w rw h 0 weight ( r ead only) w rf h 0 read result ( r ead only) w rt h 0 read total ( r ead only) w rg h 0 read prescription gr oup w rc h 0 circle w rb h 0 read s tatus ( r ead only) w mz h 0 zero ( w rite only) w mt h 0 tare ( w rite only) w ct h 0 clear tare ( w rite only) w dt h 0 clear total ( w rite only) w bb h 0 start ( w rite only) w hb h 0 stop ( w rite only) w bd h 0 discharge ( w rite only) w r p1t . rp6f h 0 read/write r ecipe www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 151 wiring d iagram: the following represents the view of hmi & plc. e mt 3 000 series com1 rs232 9p d - sub fem ale com 3 rs232 9p d - sub fem ale cb4 rs232 2 rx 8 rx t d 3 tx 7 tx r d 5 gnd 5 gnd gnd mt6000 /8000 series except mt6050i/mt8050i com1 rs232 9p d - sub fem ale com2 rs232 9p d - sub fem ale com3 rs232 9p d - sub m ale cb4 rs232 2 rx 6 rx 8 rx t d 3 tx 4 tx 7 tx r d 5 gnd 5 gnd 5 gnd gnd mt6050i/mt8050i com1 rs232 9p d - sub fem ale cb4 rs232 9 rx t d 6 tx r d 5 gnd gnd driver version : version date description v1. 40 nov/04/2009 www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 152 kernel sistemi dmx series supported s eries: kernel systemi dmx 30 website: http://www.kern el.modena.it/ hmi setting: parameters recommend ed option s notes plc type kernel sistemi dmx series plc i/f rs232 rs485 baud rate 19200 9600 data b its 8 parity none stop b its 1 plc s t a . n o. 1 must match the plc port setting device a ddre ss: bit/word device t ype format range memo w d hhhh 0 ~ ffff wiring d iagram: the following represents the view of hmi & plc. e mt 3 000 series com1 rs232 9p d - sub fem ale com 3 rs232 9p d - sub fem ale dmx30 rs232 9p d - sub male 2 rx 8 rx 3 t x 3 tx 7 tx 2 r x 5 gnd 5 gnd 5 gnd www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 153 mt6000 /8000 series except mt6050i/mt8050i com1 rs232 9p d - sub fem ale com2 rs232 9p d - sub fem ale com3 rs232 9p d - sub m ale dmx30 rs232 9p d - sub male 2 rx 6 rx 8 rx 3 t x 3 tx 4 tx 7 tx 2 r x 5 gnd 5 gnd 5 gnd 5 gnd mt6050i/mt8050i com1 rs232 9p d - sub fem ale dmx30 rs232 9p d - sub male 9 rx 3 t x 6 tx 2 r x 5 gnd 5 gnd driver version : version date description v1.00 feb/0 6 /2010 driver releasesd . www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 154 k eyence kv - 10/16/24/40/80/visual kv s eries supporte d s eries: keyence kv series, kv16~80 website: http://www.keyence.com/ hmi setting: parameters recommend ed option s notes plc type keyence kv - 10/16/24/40/80/visual kv series plc i/f rs232 rs232 baud rate 9 6 00 data b its 8 parity even stop b its 1 plc s t a . n o. 0 device a ddress: bit/word device t ype format range memo b r ly ddddd 0 * 0 ~ 65515 0 * dd :0 ~ 15 b dm_bit dddddh 0 ~ 65535f w dm ddddd 0 ~ 65535 w tm dddd 0 ~ 8999 w t dddd 0 ~ 9 999 w t_ curr dddd 0 ~ 9 999 timer_current w t_preset dddd 0 ~ 9 999 w c dddd 0 ~ 9 999 w c_curr dddd 0 ~ 9 999 counter_current w c_preset dddd 0 ~ 9 999 note : * if relay (bit) register is used , p lease place a zero at the end of the address . for example, to read relay (bit) 100, the address is written as 100 0 . www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 155 wiring d iagram: the following represents the view of hmi & plc. rs232 cpu port: e mt 3 000 series com1 rs232 9p d - sub fem ale com 3 rs232 9p d - sub fem ale op - 26486 9p d - sub male 2 rx 8 rx 3 t x d 3 tx 7 tx 2 r x d 5 gnd 5 gnd 5 gnd mt6000 /8000 series except mt6050i/mt8050i com1 rs232 9p d - sub fem ale com2 rs232 9p d - sub fem ale com3 rs232 9p d - sub m ale op - 26486 9p d - sub male 2 rx 6 rx 8 rx 3 t x d 3 tx 4 tx 7 tx 2 r x d 5 gnd 5 gnd 5 gnd 5 gnd mt6050i/mt8050i com1 rs232 9p d - sub fem ale op - 26486 9p d - sub male 9 rx 3 t x d 6 tx 2 r x d 5 gnd 5 gnd www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 156 the following represents the view of hmi & plc. 9p d - sub to 6 p r j 11 : e mt 3 000 series com1 rs232 9p d - sub fem ale com 3 rs232 9p d - sub fe m ale rs232 6p rj11 male 2 rx 8 rx 2 tx d 3 tx 7 tx 4 rx d 5 gnd 5 gnd 3 gnd mt6000 /8000 series except mt6050i/mt8050i com1 rs232 9p d - sub fem ale com2 rs232 9p d - sub fem ale com3 rs232 9p d - sub m ale rs232 6p rj11 male 2 rx 6 rx 8 rx 2 tx d 3 t x 4 tx 7 tx 4 rx d 5 gnd 5 gnd 5 gnd 3 gnd mt6050i/mt8050i com1 rs232 9p d - sub fem ale rs232 6p rj11 male 9 rx 2 tx d 6 tx 4 rx d 5 gnd 3 gnd driver version : version date description v1. 4 0 apr/17/2009 www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 157 keyence kv - 5000 (ether net) s upported series: kv5000, 3000, 1000 series. website: http://www.keyence.com/ hmi setting: parameters recommend ed option s notes plc type keyence kv - 5000 (ethernet) plc i/f ethernet p ort n o. 8501 plc s t a . n o. 0 device a ddress: bit/word device t ype format range memo b mr ddddd 0 ~ 99915 b lr ddddd 0 ~ 99915 b cr ddddd 0 ~ 99915 b r ly ddddd 0 ~ 99915 w dm ddddd 0 ~ 65535 w tm dddd 0 ~ 99 99 w t dddd 0 ~ 9999 w t_curr dddd 0 ~ 99 99 timer current w t_preset dddd 0 ~ 99 99 timer preset w c dddd 0 ~ 99 99 w c _ curr dddd 0 ~ 99 99 w c_preset dddd 0 ~ 99 99 w cm ddddd 0 ~ 65535 w em ddddd 0 ~ 65535 w fm ddddd 0 ~ 65535 note : if rly (bit) register is used , p lease place a zero at the en d of the address. for example, to read rly 100, the address is written as 1000. www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 158 wiring d iagram: direct connect (crossover cable): hmi rj45 male wire color wire color plc rj45 male 1 tx+ white/orange white/green 3 rx+ 2 tx - orange green 6 rx - 3 rx+ w hite/green white/orange 1 tx+ 4 bd4+ blue blue 4 bd4+ 5 bd4 - white/blue white/blue 5 bd4 - 6 rx - green orange 2 tx - 7 bd3+ white/brown white/brown 7 bd3+ 8 bd3 - brown brown 8 bd3 - through a hub: hmi rj45 male wire color wire color plc rj45 male 1 tx+ white/orange white/orange 1 tx+ 2 tx - orange orange 2 tx - 3 rx+ white/green white/green 3 rx+ 4 bd4+ blue blue 4 bd4+ 5 bd4 - white/blue white/blue 5 bd4 - 6 rx - green green 6 rx - 7 bd3+ white/brown white/brown 7 bd3+ 8 bd3 - brown brown 8 bd3 - driver version : version date description v1.00 dec/25/2009 driver released . www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 159 keyence kv - 700/ 1000 /3000/5000 series website: http://www.keyence.com/ hmi setting: parameters recommend ed option s notes plc ty pe keyence kv - 700/1000/3000/5000 series plc i/f rs232 rs232 baud rate 115200 data b its 8 parity even stop b its 1 plc s t a . n o. 0 device a ddress: bit/word device t ype format range memo b mr ddddd 0 ~ 99915 b lr ddddd 0 ~ 99915 b cr d dddd 0 ~ 99915 b rly ddddd 0 ~ 99915 w dm ddddd 0 ~ 65535 w tm dddd 0 ~ 9999 w t dddd 0 ~ 9999 w t_curr dddd 0 ~ 9999 timer_current w t_preset dddd 0 ~ 9999 w c dddd 0 ~ 9999 w c_curr dddd 0 ~ 9999 counter_current w c_preset dddd 0 ~ 9999 w cm ddddd 0 ~ 65535 w em ddddd 0 ~ 65535 w fm ddddd 0 ~ 65535 note : if relay (bit) register is used , p lease place a zero at the end of the address. for example, to read relay (bit) 100, the address is written as 1000. www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 160 wiring d iagram: the follo wing represents the view of hmi & plc. e mt 3 000 series com1 rs232 9p d - sub fem ale com 3 rs232 9p d - sub fem ale op - 26486 9p d - sub male 2 rx 8 rx 3 t x d 3 tx 7 tx 2 r x d 5 gnd 5 gnd 5 gnd mt6000 /8000 series except mt6050i/mt8050i com1 rs232 9p d - s ub fem ale com2 rs232 9p d - sub fem ale com3 rs232 9p d - sub m ale op - 26486 9p d - sub male 2 rx 6 rx 8 rx 3 t x d 3 tx 4 tx 7 tx 2 r x d 5 gnd 5 gnd 5 gnd 5 gnd mt6050i/mt8050i com1 rs232 9p d - sub fem ale op - 26486 9p d - sub male 9 rx 3 t x d 6 tx 2 r x d 5 gnd 5 gnd driver version : version date description v2.20 jul/28/2009 www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 161 korenix 6550 website : http://www.korenix.com/ hmi setting: parameters recommend ed option s notes plc type korenix 6550 m odbus protocol plc i/f ethernet port n o. 502 plc s t a . n o. 0 device a ddress: bit/word device type format range memo b 1 x ddddd 1 ~ 65535 b 0 x ddddd 1 ~ 65535 b 3x_bit ddddddd 1 00 ~ 6553515 b 4x_bit ddddddd 1 00 ~ 6553515 b 6x_bit ddddddd 1 00 ~ 6553515 w 3 x ddddd 1 ~ 65535 w 4 x ddddd 1 ~ 65535 w 5 x ddddd 1 ~ 65535 w 6 x ddddd 1 ~ 65535 www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 162 wiring d iagram: direct connect (crossover cable): hmi rj45 male wire color wire color plc rj45 male 1 tx+ white/orange white/green 3 rx+ 2 tx - o range green 6 rx - 3 rx+ white/green white/orange 1 tx+ 4 bd4+ blue blue 4 bd4+ 5 bd4 - white/blue white/blue 5 bd4 - 6 rx - green orange 2 tx - 7 bd3+ white/brown white/brown 7 bd3+ 8 bd3 - brown brown 8 bd3 - through a hub: hmi rj45 male wire color wire color plc rj45 male 1 tx+ white/orange white/orange 1 tx+ 2 tx - orange orange 2 tx - 3 rx+ white/green white/green 3 rx+ 4 bd4+ blue blue 4 bd4+ 5 bd4 - white/blue white/blue 5 bd4 - 6 rx - green green 6 rx - 7 bd3+ white/brown white/brown 7 bd3+ 8 bd3 - brown brown 8 bd3 - driver version : version date description v1.61 apr/17/2009 www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 163 koyo click supported s eries: k oyo click plc series website: http://www.automationdirect.com hmi setting: par ameters recommend ed option s notes plc type koyo click plc i/f rs232 baud rate 38400 com port1 (fixed) reference plc specification data b its 8 com port1 (fixed) reference plc specification parity odd com port1 (fixed) reference plc specification st op b its 1 com port1 (fixed) reference plc specification plc s t a . n o. 1 com port1 (fixed) reference plc specification device a ddress: bit/word device t ype format range memo b x ddd 001 ~ 816 input status (read only) b y ddd 001 ~ 816 output status b c dddd 1 ~ 2000 control bit b t ddd 1 ~ 500 timer status (read only) b ct ddd 1 ~ 250 counter status (read only) b sc dddd 1 ~ 1000 system control bit (read only) w ds dddd 1 ~ 4500 data registers w dd dddd 1 ~ 1000 data registers (double w ord) w dh d dd 1 ~ 500 data registers w df ddd 1 ~ 500 data registers (double w ord) w xd d 0 ~ 8 input status registers (read only) w yd d 0 ~ 8 o ut put status registers w td ddd 1 ~ 500 timer current values (read only) w ctd ddd 1 ~ 250 counter current values (d ouble w ord/read only) w sd dddd 1 ~ 1000 system data registers (read only) w txt dddd 1 ~ 1000 text data registers www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 164 wiring d iagram: koyo click plc com port: the following represents the view of hmi & plc. driver e mt 3 000 series com1 rs232 9p d - sub fem ale com 3 rs232 9p d - sub fem ale rs232 6 p rj12 male 2 rx 8 rx 4 t xd 3 tx 7 tx 3 r xd 5 gnd 5 gnd 1 gnd mt6000 /8000 series except mt6050i/mt8050i com1 rs232 9p d - sub fem ale com2 rs232 9p d - sub fem ale com3 rs232 9p d - sub m ale rs232 6 p rj12 male 2 rx 6 rx 8 rx 4 t xd 3 tx 4 tx 7 tx 3 r xd 5 gnd 5 gnd 5 gnd 1 gnd www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 165 mt6050i/mt8050i com1 rs232 9p d - sub fem ale rs232 6 p rj12 male 9 rx 4 t xd 6 tx 3 r xd 5 gnd 1 gnd version : version date description v1.50 jun/22/2010 www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 166 k oyo d irect supported s eries: koyo directlogic series plc dl05, dl06 , dl105, dl205, dl305 , and dl405 series . website: http://www.automationdirect.com hmi setting: parameters recommend ed option s notes plc t ype koyo direct plc i/f rs232 rs232, rs485 baud rate 9600 9600, 19200, 38400 data b its 8 7, 8 parity odd even, odd, none stop b its 1 1 plc s t a . n o. 1 1 - 90 plc setting: 1. the plc must not have a password. 2. plc must be set for full duplex operat ion. 3. plc must be set for no hardware handshaking. 4. the plc must be set to use the k sequence protocol. 5. set the mode switch to the term mode . 6. when usi ng the d4 - 440 cpu, the station number must be set to 1. www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 167 device a ddress: bit/word device t ype format ran ge memo b x oooo 0 ~ 4000 input bits b y oooo 0 ~ 4000 output bits b c ooooo 0 ~ 10000 control relays b t oooo 0 ~ 1000 timer status bits b ct oooo 0 ~ 1000 counter status bits b s oooo 0 ~ 2000 b sp oooo 0 ~ 2000 b gx ooooo 0 ~ 10000 b gy oooo o 0 ~ 10000 w v ooooo 0 ~ 77777 v memory w timer oooo 0 ~ 1000 w counter oooo 0 ~ 1000 wiring d iagram: the following represents the view of hmi & plc. dl05/dl 06 /dl105/dl230/dl240/dl250/dl350/dl450 rs232 port e mt 3 000 series com1 rs232 9p d - sub fem al e com 3 rs232 9p d - sub fem ale koyo click plc rs232 6 p rj12 male 2 rx 8 rx 4 t x 3 tx 7 tx 3 r x 5 gnd 5 gnd 1 gnd mt6000 /8000 series except mt6050i/mt8050i com1 rs232 9p d - sub fem ale com2 rs232 9p d - sub fem ale com3 rs232 9p d - sub m ale koyo cli ck plc rs232 6 p rj12 male 2 rx 6 rx 8 rx 4 t x 3 tx 4 tx 7 tx 3 r x 5 gnd 5 gnd 5 gnd 1 gnd www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 168 mt6050i/mt8050i com1 rs232 9p d - sub fem ale koyo click plc rs232 6 p rj12 male 9 rx 4 t x 6 tx 3 r x 5 gnd 1 gnd the following represents the view of hmi & plc. cpu unit: dl06/dl250 cpu port2 rs232 e mt 3 000 series com1 rs232 9p d - sub fem ale com 3 rs232 9p d - sub fem ale rs232 port2 15p d - sub male 2 rx 8 rx 2 tx 3 tx 7 tx 3 rx 5 gnd 5 gnd 7 gnd 4 rtc circuit 5 cts mt6000 /800 0 series except mt6050i/mt8050i com1 rs232 9p d - sub fem ale com2 rs232 9p d - sub fem ale com3 rs232 9p d - sub m ale rs232 port2 15p d - sub male 2 rx 6 rx 8 rx 2 tx 3 tx 4 tx 7 tx 3 rx 5 gnd 5 gnd 5 gnd 7 gnd 4 rtc circuit 5 cts www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 169 mt6050i/mt8050 i com1 rs232 9p d - sub fem ale rs232 port2 15p d - sub male 9 rx 2 tx 6 tx 3 rx 5 gnd 7 gnd 4 rtc circuit 5 cts the following represents the view of hmi & plc. cpu unit: dl06/ dl250 cpu port2 rs422 e mt 3 000 series com1 rs485 4 w 9p d - sub m ale rs422 port2 15p d - sub male 1 rx - 1 0 tx - 2 r x + 9 tx+ 3 tx - 6 rx - 4 tx+ 13 rx+ 5 gnd 7 gnd 11 rts+ c ircuit 14 cts+ 12 rts - c ircuit 15 cts - www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 170 mt6000 /8000 series except mt6050i/mt8050i com1 rs485 4 w 9p d - sub m ale rs4 22 port2 15p d - sub male 1 rx - 1 0 tx - 2 r x + 9 tx+ 3 tx - 6 rx - 4 tx+ 13 rx+ 5 gnd 7 gnd 11 rts+ c ircuit 14 cts+ 12 rts - c ircuit 15 cts - mt6050i/mt8050i com1 rs485 4 w 9p d - sub fem ale rs422 port2 15p d - sub male 1 rx - 1 0 tx - 2 r x + 9 tx+ 3 tx - 6 rx - 4 tx+ 13 rx+ 5 gnd 7 gnd 11 rts+ c ircuit 14 cts+ 12 rts - c ircuit 15 cts - note: dl06/ dl250 cpu port2 include rs232 and rs422 www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 171 the following represents the view of hmi & plc. dl430/dl440/dl450 cpu unit port0 rs232 e mt 3 000 series com1 rs232 9p d - sub fem ale com 3 rs232 9p d - sub fem ale rs232 port0 15p d - sub male 2 rx 8 rx 2 tx 3 tx 7 tx 3 rx 5 gnd 5 gnd 13 gnd 1 yop circuit 7 cts 2 yom 4 online circuit 14 gnd mt6000 /80 00 series except mt6050i/mt8050i com1 rs232 9p d - sub fem ale com2 rs232 9p d - sub fem ale com3 rs232 9p d - sub m ale rs232 port0 15p d - sub male 2 rx 6 rx 8 rx 2 tx 3 tx 4 tx 7 tx 3 rx 5 gnd 5 gnd 5 gnd 13 gnd 1 yop circuit 7 cts 2 yom 4 onlin e circuit 14 gnd www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 172 mt6050i/mt8050i com1 rs232 9p d - sub fem ale rs232 port0 15p d - sub male 9 rx 2 tx 6 tx 3 rx 5 gnd 13 gnd 1 yop circuit 7 cts 2 yom 4 online circuit 14 gnd the following represents the vie w of hmi & plc. cpu unit: dl430/dl440/dl450 cpu unit port1 & dl350 cpu unit port2 rs232 e mt 3 000 series com1 rs232 9p d - sub fem ale com 3 rs232 9p d - sub fem ale rs232 port1 25p d - sub male 2 rx rx 2 tx 3 tx 7 tx 3 rx 5 gnd 5 gnd 7 gnd 4 rtc c ircuit 5 cts www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 173 mt6000 /8000 series except mt6050i/mt8050i com1 rs232 9p d - sub fem ale com2 rs232 9p d - sub fem ale com3 rs232 9p d - sub m ale rs232 port1 25p d - sub male 2 rx 6 rx 8 rx 2 tx 3 tx 4 tx 7 tx 3 rx 5 gnd 5 gnd 5 gnd 7 gnd 4 rtc c ircuit 5 cts mt6050i/mt8050i com1 rs232 9p d - sub fem ale rs232 port1 25p d - sub male 9 rx 2 tx 6 tx 3 rx 5 gnd 7 gnd 4 rtc c ircuit 5 cts www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 174 the following represents the view of hmi & plc. cpu unit: dl430/dl440/dl450 cpu unit port1 & dl350 cpu unit port2 rs422 e mt 3 000 series com1 rs485 4 w 9p d - sub m ale rs422 port 25p d - sub male 1 rx - 16 tx - 2 r x + 14 tx+ 3 tx - 1 0 rx - 4 tx+ 9 rx+ 5 gnd 7 gnd 19 rts+ c ircuit 11 cts+ 18 rts - c ircuit 23 cts - mt6000 /8000 series except mt6050i/mt8050i com1 rs485 4 w 9p d - sub m ale rs422 port 25p d - sub male 1 rx - 16 tx - 2 r x + 14 tx+ 3 tx - 1 0 rx - 4 tx+ 9 rx+ 5 gnd 7 gnd 19 rts+ c ircuit 11 cts+ 18 rts - c ircuit 23 cts - www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 175 mt6050i/m t8050i com1 rs485 4 w 9p d - sub fem ale rs422 port 25p d - sub male 1 rx - 16 tx - 2 r x + 14 tx+ 3 tx - 1 0 rx - 4 tx+ 9 rx+ 5 gnd 7 gnd 19 rts+ c ircuit 11 cts+ 18 rts - c ircuit 23 cts - the following represents the view of hmi & p lc. cpu unit: dl450 cpu unit port3 rs422 e mt 3 000 series com1 rs485 4 w 9p d - sub m ale rs422 port3 25p d - sub male 1 rx - 13 tx - 2 r x + 12 tx+ 3 tx - 25 rx - 4 tx+ 24 rx+ 5 gnd 7 gnd www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 176 mt6000 /8000 series except mt6050i/mt8050i com1 rs485 4 w 9p d - sub m ale rs422 port3 25p d - sub male 1 rx - 13 tx - 2 r x + 12 tx+ 3 tx - 25 rx - 4 tx+ 24 rx+ 5 gnd 7 gnd mt6050i/mt8050i com1 rs485 4 w 9p d - sub fem ale rs422 port3 25p d - sub male 1 rx - 13 tx - 2 r x + 12 tx+ 3 tx - 25 rx - 4 tx+ 24 rx+ 5 gnd 7 gnd the following represents the view of hmi & plc. communication unit: dl205 series d2 - dcm and dl405 series d4 - dcm rs232 e mt 3 000 series com1 rs232 9p d - sub fem ale com 3 rs232 9p d - sub fem ale rs232 port 25p d - sub male 2 rx 8 rx 2 tx 3 tx 7 tx 3 rx 5 gnd 5 gnd 7 gnd 4 rtc circuit 5 cts www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 177 mt6000 /8000 series except mt6050i/mt8050i com1 rs232 9p d - sub fem ale com2 rs232 9p d - sub fem ale com3 rs232 9p d - sub m ale rs232 port 25p d - sub male 2 rx 6 rx 8 rx 2 tx 3 tx 4 tx 7 tx 3 rx 5 gnd 5 gnd 5 gnd 7 gnd 4 rtc circuit 5 cts mt6050i/mt8050i com1 rs232 9p d - sub fem ale rs232 port 25p d - sub male 9 rx 2 tx 6 tx 3 rx 5 gnd 7 gnd 4 rtc circuit 5 cts driver version : version da te description v1. 3 0 nov/08 /2010 www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 178 koyo ethernet supported s eries: koyo directlogic series, model h0 - ecom100 , h2 - ecom100 . website: http://www.automationdirect.com hmi setting: parameters recommend ed opt ion s notes plc type koyo ethernet plc i/f ethernet udp/ip port n o. 28784 plc s t a . n o. no need to set station no. 0 device a ddress: bit/word device t ype format range memo b gx oooo 0 ~ 3777 global i/o b x oooo 0 ~ 1777 real word inputs b sp oo oo 0 ~ 1777 special purpose relays b gy oooo 0 ~ 3777 more global i/o b y oooo 0 ~ 1777 real word outputs b c oooo 0 ~ 3777 control relays b s oooo 0 ~ 1777 stage status bits b t ooo 0 ~ 377 timer status bits b ct ooo 0 ~ 377 counter status bits w v ooooo 0 ~ 41237 v - memory w c c m_32 hhh 1 ~ 200 gx, x, sp w ccm_33 hhh 1 ~ 340 gy,y,c,s, t ,ct w ccm_31 hhhh 1 ~ 42 a 0 v ddd:decimal, hhh:hexadecimal, ooo:octal www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 179 the mapping of ccm32, ccm33, and ccm31 with other addresses. device type range device type ran ge ccm_31 1~42a0 v 0~41237 ccm_32 1~ff gx 0~3777 ccm_32 101~17f x 0~1777 ccm_32 181~1ff sp 0~1777 ccm_33 1~ff gy 0~3777 ccm_33 101~17f y 0~1777 ccm_33 181~27f c 0~3777 ccm_33 281~2ff s 0~1777 ccm_33 301~31f t 0~377 ccm_33 321~33f ct 0~3 77 wiring d iagram: direct connect (crossover cable): hmi rj45 male wire color wire color plc rj45 male 1 tx+ white/orange white/green 3 rx+ 2 tx - orange green 6 rx - 3 rx+ white/green white/orange 1 tx+ 4 bd4+ blue blue 4 bd4+ 5 bd4 - white/blue white /blue 5 bd4 - 6 rx - green orange 2 tx - 7 bd3+ white/brown white/brown 7 bd3+ 8 bd3 - brown brown 8 bd3 - www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 180 through a hub: hmi rj45 male wire color wire color plc rj45 male 1 tx+ white/orange white/orange 1 tx+ 2 tx - orange orange 2 tx - 3 rx+ white /green white/green 3 rx+ 4 bd4+ blue blue 4 bd4+ 5 bd4 - white/blue white/blue 5 bd4 - 6 rx - green green 6 rx - 7 bd3+ white/brown white/brown 7 bd3+ 8 bd3 - brown brown 8 bd3 - driver version : version date description v1.10 jul/03/2009 www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 181 lenze s upported s eries: plc model no. : 9300/8200 series , and epl10200 pass - through 2102ib fieldbus module : rs485 (lecom b) website: http://www.lenze. de hmi setting: parameters recommend ed option s notes plc type lenze plc i/f rs 232 baud rate 9600 9600, 1 9200 data b its 7 7, 8 parity none even, odd, none stop b its 1 1 , 2 plc s t a . n o. 1 0 - 255 plc setting: communication mode same as the mt500 setting device a ddress: bit/word device t ype format range memo b cnb dddddd 0 ~ 999915 subcode not suppo rted. can only read/write cni word type. b cb ddddddxx 0 ~ 81920015 subcode supported. c an only read/write ci word type. w ci dddddd 0 ~ 819200 subcode supported. integer w cd dddddd 0 ~ 819200 subcode supported. dword w cf dddddd 0 ~ 819200 subcode s upported. dword (float point) w cni dddd 0 ~ 9999 subcode not supported. i nteger w cnd dddd 0 ~ 9999 subcode not supported. dword w cnf dddd 0 ~ 9999 subcode not supported. dword (float point) www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 182 wiring d iagram: the following represents the view of hmi & plc. lenze 2102ib lecom - b rs485 plug - in terminal 4 - pole e mt 3 000 series com1 rs485 2 w 9p d - sub m ale com 3 rs485 2 w 9p d - sub m ale rs485 terminal 1 rx - 6 data - 72 t/r (a) 2 rx+ 9 data+ 71 t/r (b) 5 gnd 5 gnd mt6000 /8000 series except mt6050i /mt8050i com1 rs485 2 w 9p d - sub m ale com 3 rs485 2 w 9p d - sub m ale rs485 terminal 1 rx - 6 data - 72 t/r (a) 2 rx+ 9 data+ 71 t/r (b) 5 gnd 5 gnd mt6050i/mt8050i com1 rs485 2 w 9p d - sub fem ale com 3 rs485 2 w 9p d - sub fem ale rs485 terminal 1 rx - 7 data - 72 t/r (a) 2 rx+ 8 data+ 71 t/r (b) 5 gnd 5 gnd driver version : version date description v1.20 sep/6/2011 www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 183 lingyan bms website: http://www.lyeda.com/project_file/bms0 1.htm hmi setting: parameters recommend ed option s notes plc type lingyan bms plc i/f rs232 baud rate 9600 data b its 8 parity none stop b its 1 plc s t a . n o. 0 device a ddress: bit/word device t ype format range memo w battery_unit d 0 w insulator_unit d 0 w switch_unit d 0 wiring d iagram: the following represents the view of hmi & plc. e mt 3 000 series com1 rs232 9p d - sub fem ale com 3 rs232 9p d - sub fem ale rs232 4p terminal 2 rx 8 rx 1 t x d 3 tx 7 tx 3 r x d 5 gnd 5 gnd 4 gnd www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 184 mt6000 /8000 series except mt6050i/mt8050i com1 rs232 9p d - sub fem ale com2 rs232 9p d - sub fem ale com3 rs232 9p d - sub m ale rs232 4p terminal 2 rx 6 rx 8 rx 1 t x d 3 tx 4 tx 7 tx 3 r x d 5 gnd 5 gnd 5 gnd 4 gnd mt6050i/mt8050i com1 rs232 9p d - sub fem ale rs232 4p terminal 9 rx 1 t x d 6 tx 3 r x d 5 gnd 4 gnd driver version : version date description v1. 1 0 nov/12/2009 www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 185 liyan ex series supported s eries : liyan plc ex/ex1s /ex1n/ex2n series website: http://www.liyanplc.com/ hmi setting: parameters rec ommend ed option s notes plc type mitsubishi fx0s/fx0n/fx1s/fx1n/fx2 plc i/f rs232 rs232 baud rate 9600 9600~ 115200 data b its 7 7, 8 parity even even, odd, none stop b its 1 1 ,2 plc s t a . n o. 0 0 - 255 must match the plc port setting. device a ddress: bit/word device t ype format range memo b x ooo 0 ~ 377 input r elay b y ooo 0 ~ 377 output r elay b m ddd 0 ~ 9999 internal b it m emory b t ddd 0 ~ 255 timer b it m emory b c ddd 0 ~ 255 counter b it m emory w tv ddd 0 ~ 255 timer r egister w cv ddd 0 ~ 199 counter r egister w d ddd 0 ~ 9999 da ta r egister w cv2 ddd 200 ~ 255 counter register (double w ord) w sd ddd 8000 ~ 9999 specia l d ata r egister www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 186 wiring d iagram: the following represents the view of hmi & plc. 9p d - sub to 8 p m ini - din : ex, ex1s, ex1n, ex2n series e mt 3 000 series com1 rs232 9p d - sub fem ale com 3 rs232 9p d - sub fem ale rs232 8p m ini - din male 2 rx 8 rx 2 t xd 3 tx 7 tx 7 r xd 5 gnd 5 gnd 6 gnd mt6000 /8000 series except mt6050i/mt8050i com1 rs232 9p d - sub fem ale com2 rs232 9p d - sub fem ale com3 rs232 9p d - sub m ale rs232 8p m ini - din male 2 rx 6 rx 8 rx 2 t xd 3 tx 4 tx 7 tx 7 r xd 5 gnd 5 gnd 5 gnd 6 gnd mt6050i/mt8050i com1 rs232 9p d - sub fem ale rs232 8p m ini - din male 9 rx 2 t xd 6 tx 7 r xd 5 gnd 6 gnd driver version : version date description v1. 2 0 oct / 26 /20 11 www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 187 loxin website: http://www. loxin - china.com hmi setting: parameters recommend ed option s notes plc type loxin plc i/f rs - 485 2w baud rate 9600 data bits 8 parity odd stop bits 1 plc s t a . n o. 0 device address: bit/word device type format range memo w battery_un it d 0 w insulator_unit d 0 w switch_unit d 0 wiring diagram: the following represents the view of hmi & plc. e mt 3 000 series com1 rs485 2 w 9p d - sub m ale com 3 rs485 2 w 9p d - sub m ale rs 485 terminal 1 rx - 6 data - d - 2 rx+ 9 data+ d+ 5 gnd 5 gn d www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 188 mt6000 /8000 series except mt6050i/mt8050i com1 rs485 2 w 9p d - sub m ale com 3 rs485 2 w 9p d - sub m ale rs 485 terminal 1 rx - 6 data - d - 2 rx+ 9 data+ d+ 5 gnd 5 gnd mt6050i/mt8050i com1 rs485 2 w 9p d - sub fem ale com 3 rs485 2 w 9p d - sub fem ale rs 485 terminal 1 rx - 7 data - d - 2 rx+ 8 data+ d+ 5 gnd 5 gnd driver version : version date description v 1.00 oct/16/2008 www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 189 ls glofa cnet supported s eries: ls glofa gm6/gm7 cpu port. g7l - cueb / g6l - cueb / g4l - cuea / g3l - cuea c net module website: http://www.lgis.com/ hmi setting: parameters recommend ed option s notes plc type ls glofa cnet plc i/f rs232 rs232/rs485 2w/4w baud rate 9600 9600~115200 data b its 8 7, 8 parity none even, odd, none stop b its 1 1 plc s t a . n o. 0 0~31 plc setting: communication mode 9600,n,8,1 (default), cnet protocol communication module applicable mode: 1 d edicated communication device a ddress: bit/word device t ype format range memo b mx ddddd 0 ~ 32767 internal r elay b ix ddddd 0 ~ 63763 input b qx ddddd 0 ~ 63763 output w mw ddddd 0 ~ 32767 data r egister dw md ddddd 0 ~ 16383 double w ord www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 190 wiring d iagram: the following represents the view of hmi & plc. 9p d - sub to 9p d - sub: e mt 3 000 series com1 rs232 9p d - sub fem ale com 3 rs232 9p d - sub fem ale rs232 9p d - sub male 2 rx 8 rx 7 t x d 3 tx 7 tx 4 r x d 5 gnd 5 gnd 5 gnd mt6000 /8000 series except mt6050i/mt8050i com1 rs232 9p d - sub fem ale com2 rs232 9p d - sub fem ale com3 rs232 9p d - sub m ale rs232 9p d - sub male 2 rx 6 rx 8 rx 7 t x d 3 tx 4 tx 7 tx 4 r x d 5 gnd 5 gnd 5 gnd 5 gnd mt6050i/mt8050i com1 rs232 9p d - sub fem ale rs232 9p d - sub male 9 rx 7 t x d 6 tx 4 r x d 5 gnd 5 gnd www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 191 the following represents the view of hmi & plc. 9p d - sub to 9p d - sub: communication module (g7l - cueb / g6l - cueb / g4l - cuea / g3l - cuea cnet rs232) e mt 3 000 series com1 rs232 9p d - sub fem ale com 3 rs232 9p d - sub fem ale rs232 9p d - sub male 2 rx 8 rx 3 t x d 3 tx 7 tx 2 r x d 5 gnd 5 gnd 5 g nd 1 cd circuit 7 rts 8 cts 4 dtr circuit 6 dsr mt6000 /8000 series except mt6050i/mt8050i com1 rs232 9p d - sub fem ale com2 rs232 9p d - sub fem ale com3 rs232 9p d - sub m ale rs232 9p d - sub male 2 rx 6 rx 8 rx 3 t x d 3 tx 4 tx 7 tx 2 r x d 5 gnd 5 gnd 5 gnd 5 gnd 1 cd circuit 7 rts 8 cts 4 dtr circuit 6 dsr www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 192 mt6050i/mt8050i com1 rs232 9p d - sub fem ale rs232 9p d - sub male 9 rx 3 t x d 6 tx 2 r x d 5 gnd 5 gnd 1 cd circuit 7 rts 8 cts 4 dtr circuit 6 d sr the following represents the view of hmi & plc. communication module (g7l - cuec / g6l - cuec / g4l - cuea / g3l - cuea cnet rs422) e mt 3 000 series com1 rs485 4 w 9p d - sub m ale rs 422 terminal 1 rx - sdb 2 r x + sda 3 tx - rdb 4 tx+ rda 5 gnd gnd www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 193 mt6000 /8000 series except mt6050i/mt8050i com1 rs485 4 w 9p d - sub m ale rs 422 terminal 1 rx - sdb 2 r x + sda 3 tx - rdb 4 tx+ rda 5 gnd gnd mt6050i/mt8050i com1 rs485 4 w 9p d - sub fem ale rs 422 terminal 1 rx - sdb 2 r x + sda 3 tx - rdb 4 tx+ rda 5 gnd gnd driver version : version date description v1. 8 0 jun/08/2010 www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 194 ls glofa fe net (ethernet) website: http://www.lgis.com/ hmi setting: parameters recommend ed option s notes plc type ls glofa fe net (ethernet) plc i/f ethernet port no. 2004 plc s t a . n o. 0 0~31 device a ddress: bit/word device t ype format range memo b mx ddddd d 0 ~ 131056 internal r elay b ix ddddd 0 ~ 63763 input b qx dddd d 0 ~ 63763 output w mw dddd 0 ~ 8191 data r egister dw md dddd 0 ~ 4095 double w ord www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 195 wiring d iagram: direct connect (crossover cable): hmi rj45 male wire color wire color plc rj45 male 1 tx+ white/orange white/green 3 rx+ 2 tx - orange green 6 rx - 3 rx+ white/green white/orange 1 tx+ 4 bd4+ blue blue 4 bd4+ 5 bd4 - white/blue white/blue 5 bd4 - 6 rx - green orange 2 tx - 7 bd3+ white/brown white/brown 7 bd3+ 8 bd3 - brown brown 8 bd3 - through a hub: hmi rj45 male wire color wire color plc rj45 male 1 tx+ white/orange white/orange 1 tx+ 2 tx - orange orange 2 tx - 3 rx+ white/green white/green 3 rx+ 4 bd4+ blue blue 4 bd4+ 5 bd4 - white/blue white/blue 5 bd4 - 6 rx - green green 6 rx - 7 bd3+ white/brown white/brown 7 bd3+ 8 bd3 - brown brown 8 bd3 - driver version : version date description v1. 0 0 apr /0 2 /20 09 driver released. www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 196 ls glofa gm34 67 (l oader ) supported s eries: ls glofa series gm3, gm4, gm6, gm7 cpu port . website: http://www. lgis .com/ hmi s etting: parameters recommend ed option s notes plc type ls glofa gm3467 (loader) plc i/f rs232 baud rate 38400 data bit s 8 parity n one stop bit s 1 plc s t a . n o. 1 device a ddress: bit/word device t ype format range memo b mx dddddd 0 ~ 52 4272 b ix ddddd 0 ~ 63763 00.0.0 ~ 63.7.63 (dd.d.dd) b qx ddddd 0 ~ 63763 00.0.0 ~ 63.7.63 (dd.d.dd) w iw hhh 0 ~ 273 w qw hhh 0 ~ 273 w mw ddddd 0 ~ 32767 w md ddddd 0 ~ 16383 www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 197 wiring d iagram: the following represents the view of hmi & plc. e mt 3 000 series com1 rs232 9p d - sub fem ale com 3 rs232 9p d - sub fem ale ls glofa series rs232 9p d - sub male 2 rx 8 rx 3 t d 3 tx 7 tx 2 r d 5 gnd 5 gnd 5 gnd mt6000 /8000 series except mt6050i/mt8050i com1 rs232 9p d - sub fem ale com2 rs232 9p d - sub fem ale com3 rs232 9p d - sub m ale ls glofa series rs232 9p d - sub male 2 rx 6 rx 8 rx 3 t d 3 tx 4 tx 7 tx 2 r d 5 gnd 5 gnd 5 gnd 5 gnd mt6050i/mt8050i com1 rs232 9p d - sub fem ale ls glofa series rs232 9p d - sub male 9 rx 3 t d 6 tx 2 r d 5 gnd 5 gnd driver version : version date description v1. 3 0 mar/08/2010 www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 198 ls master - k cnet supported s eries: ls master - k series: k80s, k200s, k300s, and k1000s website: http://www. lgis .com/ hmi setting: pa rameters recommend ed option s notes plc type ls master - k cnet plc i/f rs 232 rs232/rs485 baud rate 38400 9600, 19200, 38400 data b its 8 8 parity none even, odd, none stop b its 1 1 plc s t a . n o. 0 0 - 31 must match the plc port setting. online s im ulator yes device a ddress: bit/word device t ype format range memo b p dddh 0 ~ 255 f i/o relay (p) b k dddh 0 ~ 255 f keep relay (k) b m dddh 0 ~ 255 f auxiliary relay (m) b l dddh 0 ~ 255 f link relay (l) b f dddh 0 ~ 255 f special relay (f) b d_bit dd ddh 0 ~ 9999f d _bit w tv ddd 0 ~ 255 timer present value w cv ddd 0 ~ 255 counter present value w d dddd 0 ~ 9999 data register (d) w m_word ddd 0 ~ 255 word type for m w l_word ddd 0 ~ 255 word type for l w f_word ddd 0 ~ 255 word type for f www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 199 wiri ng d iagram: the following represents the view of hmi & plc. e mt 3 000 series com1 rs232 9p d - sub fem ale com 3 rs232 9p d - sub fem ale cpu port cnet i/f rs232 9p d - sub male 2 rx 8 rx 7 t x 3 tx 7 tx 4 r x 5 gnd 5 gnd 5 gnd mt6000 /8000 series except mt6050i/mt8050i com1 rs232 9p d - sub fem ale com2 rs232 9p d - sub fem ale com3 rs232 9p d - sub m ale cpu port cnet i/f rs232 9p d - sub male 2 rx 6 rx 8 rx 7 t x 3 tx 4 tx 7 tx 4 r x 5 gnd 5 gnd 5 gnd 5 gnd mt6050i/mt8050i com1 rs232 9p d - sub fem ale cpu port cnet i/f rs232 9p d - sub male 9 rx 7 t x 6 tx 4 r x 5 gnd 5 gnd if connect ed with cnet module , please refer to cnet module document. driver version : version date description v1. 0 0 apr / 19 / 2010 driver released . v1. 1 0 may / 11 /20 11 add ed registers: d_bit, m_word, f_word, l_word www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 200 ls master - k cpu direct supported s eries: ls master - k series: k80s, k120s, k200s, k300s, k1000s , k7m. website: http://www. lgis .com/ hmi setting: parameters recommend ed opt ion s notes plc type lg master - k cpu direct plc i/f rs 232 rs232/rs485 baud rate 38400 9600, 19200, 38400 data b its 8 8 parity none even, odd, none stop b its 1 1 plc s t a . n o. 0 0 - 31 must match the plc port setting. online s imulator yes devic e a ddress: bit/word device t ype format range memo b p dddh 0 ~ 255 f i/o relay (p) b k dddh 0 ~ 255 f keep relay (k) b m dddh 0 ~ 255 f auxiliary relay (m) b l dddh 0 ~ 255 f link relay (l) b f dddh 0 ~ 255 f special relay (f) b d_bit ddddh 0 ~ 9999f d _bi t w tv ddd 0 ~ 255 timer present value w cv ddd 0 ~ 255 counter present value w d dddd 0 ~ 9999 data register (d) w m_word ddd 0 ~ 255 word type for m w l_word ddd 0 ~ 255 word type for l w f_word ddd 0 ~ 255 word type for f www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 201 wiring d iagram: the fo llowing represents the view of hmi & plc. e mt 3 000 series com1 rs232 9p d - sub fem ale com 3 rs232 9p d - sub fem ale rs232 9p d - sub male 2 rx 8 rx 3 t x 3 tx 7 tx 2 r x 5 gnd 5 gnd 5 gnd mt6000 /8000 series except mt6050i/mt8050i com1 rs232 9p d - sub fem ale com2 rs232 9p d - sub fem ale com3 rs232 9p d - sub m ale rs232 9p d - sub male 2 rx 6 rx 8 rx 3 t x 3 tx 4 tx 7 tx 2 r x 5 gnd 5 gnd 5 gnd 5 gnd mt6050i/mt8050i com1 rs232 9p d - sub fem ale rs232 9p d - sub male 9 rx 3 t x 6 tx 2 r x 5 gnd 5 gnd driver version : version date description v1. 2 0 may / 11 /20 11 add ed registers: d_bit, m_word, f_word, l_word www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 202 ls master - k modbus rtu supported s eries: ls master - k modbus rtu website: http://www. lgis .com / hmi setting: parameters recommend ed option s notes plc type ls master - k modbus rtu plc i/f rs 485 2w baud rate 9600 data b its 8 8 parity even even stop b its 1 1 plc s t a . n o. 1 device a ddress: bit/word device t ype format range memo b p d d ddh 0 ~ 9999 f i/o relay (p) b m dd d dh 0 ~ 9999 f auxiliary relay (m) b l dd d dh 0 ~ 9999 f link relay (l) b k dd d dh 0 ~ 9999 f keep relay (k) b f dd d dh 0 ~ 9999 f special relay (f) b d_bit dd d dh 0 ~ 9999 f w t ddd d 0 ~ 9999 timer (t) w c ddd d 0 ~ 9999 counter (c) w s dddd 0 ~ 9999 w d dddd 0 ~ 9999 data register (d) w t_double dddd 0 ~ 9999 w c_double dddd 0 ~ 9999 w s_double dddd 0 ~ 9999 w d_double dddd 0 ~ 9999 w f_word dddd 0 ~ 9999 w l_word dddd 0 ~ 9999 w m_word dddd 0 ~ 9999 www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 203 wi ring d iagram: the following represents the view of hmi & plc. e mt 3 000 series com1 rs232 9p d - sub fem ale com 3 rs232 9p d - sub fem ale rs232 9p d - sub male 2 rx 8 rx 3 t x 3 tx 7 tx 2 r x 5 gnd 5 gnd 5 gnd mt6000 /8000 series except mt6050i/mt8050i com1 rs232 9p d - sub fem ale com2 rs232 9p d - sub fem ale com3 rs232 9p d - sub m ale rs232 9p d - sub male 2 rx 6 rx 8 rx 3 t x 3 tx 4 tx 7 tx 2 r x 5 gnd 5 gnd 5 gnd 5 gnd mt6050i/mt8050i com1 rs232 9p d - sub fem ale rs232 9p d - sub male 9 rx 3 t x 6 tx 2 r x 5 gnd 5 gnd driver version : version date description v1. 1 0 may / 11 /20 11 add ed registers: d_bit, m_word, f_word, l_word www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 204 ls master - k10s1 supported s eries: ls master - k10s1 website: http://www. l gis .com/ hmi setting: parameters recommend ed option s notes plc type ls master - k10s1 plc i/f rs 232 rs232/rs485 baud rate 9600 data b its 8 8 parity none none stop b its 1 1 plc s t a . n o. 0 device a ddress: bit/word device t ype format range m emo b p dddh 0 ~ 255 f i/o relay (p) b k dddh 0 ~ 255 f keep relay (k) b m dddh 0 ~ 255 f auxiliary relay (m) b l dddh 0 ~ 255 f link relay (l) b f dddh 0 ~ 255 f special relay (f) b t ddd 0 ~ 255 timer (t) b c ddd 0 ~ 255 counter (c) w tv ddd 0 ~ 255 t imer present value w cv ddd 0 ~ 255 counter present value w d dddd 0 ~ 9999 data register (d) www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 205 wiring d iagram: the following represents the view of hmi & plc. driver e mt 3 000 series com1 rs232 9p d - sub fem ale com 3 rs232 9p d - sub fem ale rs232 9p d - sub m ale 2 rx 8 rx 3 t x 3 tx 7 tx 2 r x 5 gnd 5 gnd 5 gnd mt6000 /8000 series except mt6050i/mt8050i com1 rs232 9p d - sub fem ale com2 rs232 9p d - sub fem ale com3 rs232 9p d - sub m ale rs232 9p d - sub male 2 rx 6 rx 8 rx 3 t x 3 tx 4 tx 7 tx 2 r x 5 gnd 5 gnd 5 gnd 5 gnd mt6050i/mt8050i com1 rs232 9p d - sub fem ale rs232 9p d - sub male 9 rx 3 t x 6 tx 2 r x 5 gnd 5 gnd version : version date description v1.00 sep / 08 /200 9 driver released . www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 206 ls xech cnet supported s eries: ls xgb - xech cpu cnet website: http://www.lgis.com/ hmi setting: parameters rec ommend ed option s notes plc type ls x ech cnet plc i/f rs232 rs232/rs485 baud rate 115200 9600 ~ 115200 data b its 8 7, 8 parity none even, o dd, none stop b its 1 1 ,2 plc s t a . n o. 0 0 ~ 255 device a ddress: bit/word device t ype format range memo b i _bit ddd.dd.dh 0 ~ 127.15.3f input device bit b q _bit ddd.dd.dh 0 ~ 127.15.3f output device bit b u _bit dd.dd.ddh 0 ~ 31.15.31f analog flag bit b a _bit ddddddh 0 ~ 262143f automatic variable bit b m _bit ddddddh 0 ~ 131071f direct variable bit b r _bit dddddh 0 ~ 32767f direct variable bit b w _bit dddddh 0 ~ 65535f direct variable bit b f _bit d dddh 0 ~ 2047f system flag bit b k_bit ddddh 0 ~ 8399f built - in special flag bit b l_bit dddddh 0 ~ 11263f high speed link flag bit b n_bit dddddh 0 ~ 25087f p2p flag bit w a dddd dd 0 ~ 262143 automatic variable w i ddd . d d.d 0 ~ 127.15.3 input device w q dd d.dd.d 0 ~ 1 27.15.3 output device w m d ddddd 0 ~ 131071 direct variable w r dd ddd 0 ~ 32767 direct variable w w ddddd 0 ~ 65535 direct variable w f dddd 0 ~ 2047 system flag w k d ddd 0 ~ 8399 built - in special flag www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 207 bit/word device t ype format range memo w l ddddd 0 ~ 11263 high speed link flag w n ddd dd 0 ~ 25087 p2p flag w u dd .dd.dd 0 ~ 31.15.31 analog flag wiring d iagram: the following represents the view of hmi & plc. e mt 3 000 series com1 rs232 9p d - sub fem ale com 3 rs232 9p d - sub fem ale rs232 terminal 2 rx 8 rx t x 3 tx 7 tx r x 5 gnd 5 gnd sg mt6000 /8000 series except mt6050i/mt8050i com1 rs232 9p d - sub fem ale com2 rs232 9p d - sub fem ale com3 rs232 9p d - sub m ale rs232 terminal 2 rx 6 rx 8 rx t x 3 tx 4 tx 7 tx r x 5 gnd 5 gnd 5 gnd sg mt6050i/mt8050i com1 rs232 9p d - sub fem ale rs232 terminal 9 rx t x 6 tx r x 5 gnd sg www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 208 the following represents the view of hmi & plc. e mt 3 000 series com1 rs485 2 w 9p d - sub m ale com 3 rs485 2 w 9p d - sub m ale rs485 2w termina l 1 rx - 6 data - 485 - 2 rx+ 9 data+ 485+ 5 gnd 5 gnd gnd mt6000 / 8000 series except mt6050i/mt8050i com1 rs485 2 w 9p d - sub m ale com 3 rs485 2 w 9p d - sub m ale rs485 2w termina l 1 rx - 6 data - 485 - 2 rx+ 9 data+ 485+ 5 gnd 5 gnd gnd mt6050i/mt8050i com1 rs485 2 w 9p d - sub fem ale com 3 rs485 2 w 9p d - sub fem ale rs485 2w termina l 1 rx - 7 data - 485 - 2 rx+ 8 data+ 485+ 5 gnd 5 gnd gnd driver version : version date description v1. 00 aug / 2 7 /20 12 driver released . www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 209 ls xech fenet (ethernet) supported s eries: ls xgb - xech cpu e thernet module. website: http://www.lgis.com/ hmi setting: parameters recommend ed option s notes plc type ls xech fenet (ethernet) plc i/f ethernet p ort n o. 2004 device a ddress: bit/word device t ype format range memo b i_bit dd.dd.df 0 ~ 15.15.3f input device bit b q_bit dd.dd.df 0 ~ 15.15.3f output device bit b u_bit dd.dd.ddf 0 ~ 31.15.31f analog flag bit b a_bit dddddh 0 ~ 16383f automatic variable bit b m_bit ddddh 0 ~ 8191f direct variable bit b r_bit dddddh 0 ~ 10239f direct variable bit b w _bit dddddh 0 ~ 10239f direct variable bit b f _bit d dddh 0 ~ 1023f system flag bit b k_bit ddddh 0 ~ 4095f built - in special flag bit b l_bit ddddh 0 ~ 2047f high speed link flag bit b n_bit ddddh 0 ~ 5119f p2p flag bit w a dddd d 0 ~ 1 6383 automatic variable w i ddd . d d.d 0 ~ 15.15.3 input device w q dd d.dd.d 0 ~ 15.15.3 output device w m dddd 0 ~ 8191 direct variable w r dd ddd 0 ~ 10239 direct variable w w ddddd 0 ~ 10239 direct variable w f dddd 0 ~ 1023 system flag w k d ddd 0 ~ 4095 built - in special flag w l dddd 0 ~ 2047 high speed link flag w n ddd d 0 ~ 5119 p2p flag w u dd .dd.dd 0 ~ 31.15.31 analog flag www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 210 wiring d iagram: direct connect (crossover cable): hmi rj45 male wire color wire color plc rj45 male 1 tx+ white/orange white/green 3 rx+ 2 tx - orange green 6 rx - 3 rx+ white/green white/orange 1 tx+ 4 bd4+ blue blue 4 bd4+ 5 bd4 - white/blue white/blue 5 bd4 - 6 rx - green orange 2 tx - 7 bd3+ white/brown white/brown 7 bd3+ 8 bd3 - brown brown 8 bd3 - through a hu b: hmi rj45 male wire color wire color plc rj45 male 1 tx+ white/orange white/orange 1 tx+ 2 tx - orange orange 2 tx - 3 rx+ white/green white/green 3 rx+ 4 bd4+ blue blue 4 bd4+ 5 bd4 - white/blue white/blue 5 bd4 - 6 rx - green green 6 rx - 7 bd3+ white /brown white/brown 7 bd3+ 8 bd3 - brown brown 8 bd3 - driver version : version date description v1. 00 aug / 28 /20 12 driver released . www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 211 ls xgb cnet supported s eries : ls xgb/xgt series website: http://www.lgis.com/ h mi setting: parameters rec ommend ed option s notes plc type ls xgb cnet plc i/f rs232 rs232/rs485 baud rate 115200 9600 ~115200 data b its 8 7, 8 parity none even, odd, none stop b its 1 1 plc s t a . n o. 1 0 - 31 device a ddress: bit/word device t ype format range memo b p_bit ddddh 0 ~ 2047f i/o device bit b m_bit ddddh 0 ~ 2047f internal device bit b l_bit dddddh 0 ~ 11263f communication device bit b k_bit ddddh 0 ~ 2559f preservation device bit b f_bit ddddh 0 ~ 2047f special device bit ( write available from 1025) b s_bit ddddd 0 ~ 12799 relay for step control bit b d _bit dddddh 0 ~ 32767f data r egister_bit expression (d0000.0) b u_bit dh.ddh 0.000 ~ 7 f.31f xgk - cpue : hh(0~1f) b t_bit dddd 0 ~ 2047 timer device bit b c_bit dddd 0 ~ 2047 cou nter device bit w p dddd 0 ~ 2047 i/o device_2,048 points w m dddd 0 ~ 2047 internal device_4,096 points w l ddddd 0 ~ 11263 communication device_20,480 points w k dddd 0 ~ 255 9 preservation device_4,096 points w f dddd 0 ~ 2047 special device_4,096 p oint www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 212 bit/word device t ype format range memo w s ddddd 0 ~ 127 relay for step control w d ddddd 0 ~ 32767 data register_5120 words w u dh.dd 0.00 ~ 7f.31 analog data register_256 words w n ddddd 0 ~ 21503 communication data register_3,936 words w z ddd 0 ~ 127 index register_128 words w t dddd 0 ~ 2047 timer current value register_256 words w c dddd 0 ~ 2047 counter current value register_256 words wiring d iagram: the following represents the view of hmi & plc. e mt 3 000 series com1 rs232 9p d - sub fem ale com 3 rs232 9p d - sub fem ale rs232 6 p m ini - din male 2 rx 8 rx 6 t xd 3 tx 7 tx 2 r xd 5 gnd 5 gnd 3 gnd mt6000 /8000 series except mt6050i/mt8050i com1 rs232 9p d - sub fem ale com2 rs232 9p d - sub fem ale com3 rs232 9p d - sub m ale rs232 6 p m ini - din male 2 rx 6 rx 8 rx 6 t xd 3 tx 4 t x 7 tx 2 r xd 5 gnd 5 gnd 5 gnd 3 gnd www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 213 mt6050i/mt8050i com1 rs232 9p d - sub fem ale rs232 6 p m ini - din male 9 rx 6 t xd 6 tx 2 r xd 5 gnd 3 gnd driver version : version date description v1. 5 0 mar / 07 /20 11 a dd ed registers: p_bit, m_ bit, l_bit, k_bit etc v1.70 jun/28/2012 change the way to read/write s_bit. www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 214 ls xgb fenet (ethernet) supported s eries: ls xgb/xgt with xbl - emta website: http://www.lgis.com/ hmi setting: parameters recommend ed optio n s notes plc type ls xgb fenet (ethernet) plc i/f ethernet p ort n o. 2004 plc s t a . n o. 0 0~255 plc setting: communication mode f e net p r otocol device a ddress: bit/word device t ype format range memo b p_bit ddddh 0 ~ 2047f i/o device bit b m_b it ddddh 0 ~ 2047f internal device bit b l_bit dddddh 0 ~ 11263f communication device bit b k_bit ddddh 0 ~ 2559f preservation device bit b f_bit ddddh 0 ~ 2047f special device bit ( write available from 1025) b s_bit ddddd 0 ~ 12799 relay for step cont rol bit b d _bit dddddh 0 ~ 32767f data r egister_bit expression b u_bit dh.ddh 0.000 ~ 7 f.31f xgk - cpue : hh(0~1f) b t_bit dddd 0 ~ 2047 timer device bit b c_bit dddd 0 ~ 2047 counter device bit w p dddd 0 ~ 2047 i/o device_2,048 points w m dddd 0 ~ 20 47 internal device_4,096 points w l ddddd 0 ~ 11263 communication device_20,480 points w k dddd 0 ~ 255 9 preservation device_4,096 points w f dddd 0 ~ 2047 special device_4,096 point w s ddddd 0 ~ 127 relay for step control www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 215 bit/word device t ype format range memo w d ddddd 0 ~ 32767 data re gister_5120 words w u dh.dd 0.00 ~ 7f.31 analog data register_256 words w n ddddd 0 ~ 21503 communication data register_3,936 words w z ddd 0 ~ 127 index register_128 words w t dddd 0 ~ 2047 timer current value register_256 words w c dddd 0 ~ 2047 cou nter current value register_256 words wiring d iagram: direct connect (crossover cable): hmi rj45 male wire color wire color plc rj45 male 1 tx+ white/orange white/green 3 rx+ 2 tx - orange green 6 rx - 3 rx+ white/green white/orange 1 tx+ 4 bd4+ blue b lue 4 bd4+ 5 bd4 - white/blue white/blue 5 bd4 - 6 rx - green orange 2 tx - 7 bd3+ white/brown white/brown 7 bd3+ 8 bd3 - brown brown 8 bd3 - www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 216 through a hub: hmi rj45 male wire color wire color plc rj45 male 1 tx+ white/orange white/orange 1 tx+ 2 t x - orange orange 2 tx - 3 rx+ white/green white/green 3 rx+ 4 bd4+ blue blue 4 bd4+ 5 bd4 - white/blue white/blue 5 bd4 - 6 rx - green green 6 rx - 7 bd3+ white/brown white/brown 7 bd3+ 8 bd3 - brown brown 8 bd3 - driver version : version date descrip tion v1. 5 0 aug /1 6 /20 11 a dd ed register s: p_bit, m_bit, l_bit, k_bit etc v1.60 jun/28/2012 change the way to read/write s_bit. www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 217 ls xgi cnet supported s eries: ls xg i series communication module xgl - ch2a website: http:/ /www.lgis.com/ hmi setting: parameters recommend ed option s notes plc type ls xg i cnet plc i/f rs232 rs232/rs485 4w baud rate 115200 9600~115200 data b its 8 7, 8 parity none even, odd, none stop b its 1 1 plc st a . no. 0 0~255 device a ddress : bit/word device t ype format range memo b a_bit ddddddh 0 ~ 262143f b i_bit ddd.dd.dh 0 ~ 127.15.3f b q_bit ddd.dd.dh 0 ~ 127.15.3f b m_bit ddddddh 0 ~ 131071f b r_bit dddddh 0 ~ 32767f b w_bit dddddh 0 ~ 65535f b f_bit ddddh 0 ~ 2047f b k_ bit ddddh 0 ~ 8399f b l_bit dddddh 0 ~ 11263f b n_bit dddddh 0 ~ 25087f b u_bit dd.dd.ddh 0 ~ 31.15.31f w a dddddd 0 ~ 262143 w i ddd.dd.d 0 ~ 127.15.3 w q ddd.dd.d 0 ~ 127.15.3 w m dddddd 0 ~ 131071 w r ddddd 0 ~ 32767 w w ddddd 0 ~ 6553 5 w f dddd 0 ~ 2047 w k dddd 0 ~ 8399 www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 218 bit/word device t ype format range memo w l ddddd 0 ~ 11263 w n ddddd 0 ~ 25087 w u dd.dd.dd 0 ~ 31.15.31 wiring d iagram: the following represents the view of hmi & plc. 9p d - sub to 9p d - sub : e mt 3 000 series com1 rs232 9p d - sub fem ale com 3 rs232 9p d - sub fem ale xgl - ch2a ch1 rs232 9p d - sub male 2 rx 8 rx 3 t x d 3 tx 7 tx 2 r x d 5 gnd 5 gnd 5 gnd mt6000 /8000 series except mt6050i/mt8050i com1 rs232 9p d - sub fem ale com2 rs232 9p d - sub fem ale com3 rs232 9p d - sub m ale xgl - ch2a ch1 rs232 9 p d - sub male 2 rx 6 rx 8 rx 3 t x d 3 tx 4 tx 7 tx 2 r x d 5 gnd 5 gnd 5 gnd 5 gnd mt6050i/mt8050i com1 rs232 9p d - sub fem ale xgl - ch2a ch1 rs232 9p d - sub male 9 rx 3 t x d 6 tx 2 r x d 5 gnd 5 gnd www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 219 the following represents the view of hmi & plc. 9p d - sub to terminals : e mt 3 000 series com1 rs485 4 w 9p d - sub m ale xgl - ch2a ch2 5p terminal 1 rx - t xd - 2 r x + txd+ 3 tx - rxd - 4 tx+ rxd+ 5 gnd gnd mt6000 /8000 series except mt6050i/mt8050i com1 rs485 4 w 9p d - sub m ale xgl - ch2a ch2 5p terminal 1 rx - t xd - 2 r x + txd+ 3 tx - rxd - 4 tx+ rxd+ 5 gnd gnd mt6050i/mt8050i com1 rs485 4 w 9p d - sub fem ale xgl - ch2a ch2 5p terminal 1 rx - t xd - 2 r x + txd+ 3 tx - rxd - 4 tx+ rxd+ 5 gnd gnd www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 220 driver version : version date description v1. 0 0 may / 23 /20 12 driver released www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 221 ls xgi cpu direct supported s eries: ls xg i cpu rs232 port . website: http://www.lgis.com/ hmi setting: parameters recommend ed option s notes plc type ls xgi cpu direct plc i/f rs232 rs232 baud rate 115200 9600~115200 data b its 8 7, 8 parity none even, odd, none stop b its 1 1 plc s t a . n o. 1 1 device a ddress: bit/word device t ype format range memo b a_bit ddddddh 0 ~ 262143f b i_bit ddd.dd.dh 0 ~ 127.15.3f b q_bit ddd.dd.dh 0 ~ 127.15.3f b m_bit ddddddh 0 ~ 131071f b r_bit dddddh 0 ~ 32767f b w_bit dddddh 0 ~ 65535f b f_bit ddddh 0 ~ 2047f b k_bit ddddh 0 ~ 8399f b l_bit dddddh 0 ~ 11263f b n_bit dd dddh 0 ~ 25087f b u_bit dd.dd.ddh 0 ~ 31.15.31f w a dddddd 0 ~ 262143 w i ddd.dd.d 0 ~ 127.15.3 w q ddd.dd.d 0 ~ 127.15.3 w m dddddd 0 ~ 131071 w r ddddd 0 ~ 32767 w w ddddd 0 ~ 65535 w f dddd 0 ~ 2047 www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 222 bit/word device t ype format range memo w k dddd 0 ~ 8399 w l ddddd 0 ~ 11 263 w n ddddd 0 ~ 25087 w u dd.dd.dd 0 ~ 31.15.31 wiring d iagram: the following represents the view of hmi & plc. e mt 3 000 series com1 rs232 9p d - sub fem ale com 3 rs232 9p d - sub fem ale rs232 9p d - sub male 2 rx 8 rx 3 t x d 3 tx 7 tx 2 r x d 5 gnd 5 gnd 5 gnd mt6000 /8000 series except mt6050i/mt8050i com1 rs232 9p d - sub fem ale com2 rs232 9p d - sub fem ale com3 rs232 9p d - sub m ale rs232 9p d - sub male 2 rx 6 rx 8 rx 3 t x d 3 tx 4 tx 7 tx 2 r x d 5 gnd 5 gnd 5 gnd 5 gnd mt6050i/mt8050i c om1 rs232 9p d - sub fem ale rs232 9p d - sub male 9 rx 3 t x d 6 tx 2 r x d 5 gnd 5 gnd www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 223 driver version : version date description v1. 00 may /1 7 /20 12 driver released. www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 224 ls xgi fenet (ethernet) supported s eries: ls xg i series xgl - efmt ethernet m odule. website: http://www.lgis.com/ hmi setting: parameters recommend ed option s notes plc type ls xgi fenet (ethernet) plc i/f ethernet port n o. 2004 plc s t a . n o. 0 device a ddress: bit/word device t ype f ormat range memo b a_bit ddddddh 0 ~ 262143f b i_bit ddd.dd.dh 0 ~ 127.15.3f b q_bit ddd.dd.dh 0 ~ 127.15.3f b m_bit ddddddh 0 ~ 131071f b r_bit dddddh 0 ~ 32767f b w_bit dddddh 0 ~ 65535f b f_bit ddddh 0 ~ 2047f b k_bit ddddh 0 ~ 8399f b l_bit dddddh 0 ~ 11263f b n_bit dddddh 0 ~ 25087f b u_bit dd.dd.ddh 0 ~ 31.15.31f w a dddddd 0 ~ 262143 w i ddd.dd.d 0 ~ 127.15.3 w q ddd.dd.d 0 ~ 127.15.3 w m dddddd 0 ~ 131071 w r ddddd 0 ~ 32767 w w ddddd 0 ~ 65535 w f dddd 0 ~ 2047 w k dddd 0 ~ 8399 w l ddddd 0 ~ 11263 w n ddddd 0 ~ 25087 w u dd.dd.dd 0 ~ 31.15.31 www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 225 wiring d iagram: direct connect (crossover cable): hmi rj45 male wire color wire color plc rj45 male 1 tx+ white/orange white/green 3 rx+ 2 tx - orange green 6 rx - 3 rx+ white/green white/orange 1 tx+ 4 bd4+ blue blue 4 bd4+ 5 bd4 - white/blue white/blue 5 bd4 - 6 rx - green orange 2 tx - 7 bd3+ white/brown white/brown 7 bd3+ 8 bd3 - brown brown 8 bd3 - through a hub: hmi rj45 male wire color wire color plc rj 45 male 1 tx+ white/orange white/orange 1 tx+ 2 tx - orange orange 2 tx - 3 rx+ white/green white/green 3 rx+ 4 bd4+ blue blue 4 bd4+ 5 bd4 - white/blue white/blue 5 bd4 - 6 rx - green green 6 rx - 7 bd3+ white/brown white/brown 7 bd3+ 8 bd3 - brown brown 8 bd3 - driver version : version date description v1. 00 may / 21 /20 12 driver released. www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 226 l s xg k cnet supported s eries: ls xgt series communication module xgl - ch2a website: http://www.lgis.com/ hmi setting: param eters recommend ed option s notes plc type ls xg k cnet plc i/f rs232 rs232/rs485 4w baud rate 115200 9600~115200 data b its 8 7, 8 parity none even, odd, none stop b its 1 1 plc st a . no. 1 0~ 32 device a ddress: bit/word device t ype format range memo b p_bit ddddh 0 ~ 2047f i/o device bit b m_bit ddddh 0 ~ 2047f internal device bit b l_bit dddddh 0 ~ 11263f communication device bit b k_bit ddddh 0 ~ 2559f preservation device bit b f_bit ddddh 0 ~ 2047f special device bit ( write available from 1025) b s_bit ddddd 0 ~ 12799 relay for step control bit b d _bit dddddh 0 ~ 32767f data register_bit expression (d0000.0) b u_bit dh.ddh 0.000 ~ 3f.31f xgk - cpue : hh(0~1f) b t_bit dddd 0 ~ 2047 timer device bit b c_bit dddd 0 ~ 2047 counter device bi t w p dddd 0 ~ 2047 i/o device w m dddd 0 ~ 2047 internal device w l ddddd 0 ~ 11263 communication device w k dddd 0 ~ 2559 preservation device w f dddd 0 ~ 2047 special device( write available from 1025) www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 227 bit/word device t ype format range memo w s ddddd 0 ~ 127 relay for step control w d ddddd 0 ~ 32767 data register w u dh.dd 0.00 ~ 3f.31 analog data register xgk - cpue : hh(0~1f) w n ddddd 0 ~ 21503 communication data register w z ddd 0 ~ 127 index register_128 words w t dddd 0 ~ 2047 timer current value register w c dddd 0 ~ 2047 co unter current value register w r ddddd 0 ~ 32767 w zr ddddd 0 ~ 32767 wiring d iagram: the following represents the view of hmi & plc. 9p d - sub to 9p d - sub : e mt 3 000 series com1 rs232 9p d - sub fem ale com 3 rs232 9p d - sub fem ale xgl - ch2a ch1 rs232 9p d - sub male 2 rx 8 rx 3 t x d 3 tx 7 tx 2 r x d 5 gnd 5 gnd 5 gnd mt6000 /8000 series except mt6050i/mt8050i com1 rs232 9p d - sub fem ale com2 rs232 9p d - sub fem ale com3 rs232 9p d - sub m ale xgl - ch2a ch1 rs232 9p d - sub male 2 rx 6 rx 8 rx 3 t x d 3 tx 4 tx 7 tx 2 r x d 5 gnd 5 gnd 5 gnd 5 gnd www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 228 mt6050i/mt8050i com1 rs232 9p d - sub fem ale xgl - ch2a ch1 rs232 9p d - sub male 9 rx 3 t x d 6 tx 2 r x d 5 gnd 5 gnd the following represents the view of hmi & plc. 9p d - sub to terminals : e m t 3 000 series com1 rs485 4 w 9p d - sub m ale xgl - ch2a ch2 5p terminal 1 rx - t xd - 2 r x + txd+ 3 tx - rxd - 4 tx+ rxd+ 5 gnd gnd mt6000 /8000 series except mt6050i/mt8050i com1 rs485 4 w 9p d - sub m ale xgl - ch2a ch2 5p terminal 1 rx - t xd - 2 r x + txd+ 3 tx - rxd - 4 tx+ rxd+ 5 gnd gnd www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 229 mt6050i/mt8050i com1 rs485 4 w 9p d - sub fem ale xgl - ch2a ch2 5p terminal 1 rx - t xd - 2 r x + txd+ 3 tx - rxd - 4 tx+ rxd+ 5 gnd gnd driver version : version d ate description v1. 3 0 feb / 25 /20 11 a dd ed register s : p_bit, m_bit, l_bit, k_bit etc v1.40 jun/20/2012 change the way to read/write s_bit. www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 230 l s xg k f e net (ethernet) supported s eries: ls xgt series xgl - efmt ethernet module. website: http://www.lgis.com/ hmi setting: parameters recommend ed option s notes plc type ls xg k fenet (ethernet) plc i/f ethernet port n o. 2004 plc s t a . n o. 0 device a ddress: bit/word device t ype format range memo b p_bit ddddh 0 ~ 20 47f i/o device bit b m_bit ddddh 0 ~ 2047f internal device bit b l_bit dddddh 0 ~ 11263f co mmunication device bit b k_bit ddddh 0 ~ 2559f preservation device bit b f_bit ddddh 0 ~ 2047f special device bit ( write available from 1025) b s_bit ddddd 0 ~ 12799 relay for step control bit b d _bit dddddh 0 ~ 32767f data register_bit expression (d0000.0) b u_bit dh.ddh 0.000 ~ 3f.31f xgk - cpue : hh(0~1f) b t_bit dddd 0 ~ 2047 timer device bit b c_bit dddd 0 ~ 2047 counter device bit w p dddd 0 ~ 2047 i/o d evice w m dddd 0 ~ 2047 internal device w l ddddd 0 ~ 11263 communication device w k dddd 0 ~ 2559 preservation device w f dddd 0 ~ 2047 special device( write available from 1025) w s ddddd 0 ~ 127 relay for step control w d ddddd 0 ~ 32767 data regi ster www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 231 bit/word device t ype format range memo w u dh.dd 0.00 ~ 3f.31 analog data register xgk - cpue : hh(0~1f) w n ddddd 0 ~ 21503 communication data register w z ddd 0 ~ 127 index register_128 words w t dddd 0 ~ 2047 timer current value register w c dddd 0 ~ 2047 counter current value regist er w r ddddd 0 ~ 32767 w zr ddddd 0 ~ 32767 wiring d iagram: direct connect (crossover cable): hmi rj45 male wire color wire color plc rj45 male 1 tx+ white/orange white/green 3 rx+ 2 tx - orange green 6 rx - 3 rx+ white/green white/orange 1 tx+ 4 b d4+ blue blue 4 bd4+ 5 bd4 - white/blue white/blue 5 bd4 - 6 rx - green orange 2 tx - 7 bd3+ white/brown white/brown 7 bd3+ 8 bd3 - brown brown 8 bd3 - through a hub: hmi rj45 male wire color wire color plc rj45 male 1 tx+ white/orange white/orange 1 tx+ 2 tx - orange orange 2 tx - 3 rx+ white/green white/green 3 rx+ 4 bd4+ blue blue 4 bd4+ 5 bd4 - white/blue white/blue 5 bd4 - 6 rx - green green 6 rx - 7 bd3+ white/brown white/brown 7 bd3+ 8 bd3 - brown brown 8 bd3 - www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 232 driver version : version date description v1. 3 0 mar / 10 /20 11 a dd ed register s: p_bit, m_bit, l_bit, k_bit etc v1.40 jun/19/2012 change the way to read/write s_bit. www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 233 l s xgt/xgk cpu direct supported s eries: ls xgt/xgk cpu rs232 port . website: http: //www.lgis.com/ hmi setting: parameters recommend ed option s notes plc type ls xgt/xgk cpu direct plc i/f rs232 rs232 baud rate 1 15200 9600~115200 data b its 8 7, 8 parity none even, odd, none stop b its 1 1 plc s t a . n o. 1 1 device a ddress: bit/word device t ype format range memo b p_bit ddddh 0 ~ 2047f i/o device bit b m_bit ddddh 0 ~ 2047f internal device bit b l_bit dddddh 0 ~ 11263f communication device bit b k_bit ddddh 0 ~ 2559f preservation device bit b f_bit ddddh 0 ~ 2047f specia l device bit ( write available from 1025) b s_bit ddddd 0 ~ 12799 relay for step control bit b d _bit dddddh 0 ~ 32767f data register_bit expression b u_bit dh.ddh 0.000 ~ 3f.31f xgk - cpue : hh(0~1f) b t_bit dddd 0 ~ 2047 timer device bit b c_bit dddd 0 ~ 2047 counter device bit w p dddd 0 ~ 2047 i/o device w m dddd 0 ~ 2047 internal device w l ddddd 0 ~ 11263 communication device w k dddd 0 ~ 2559 preservation device w f dddd 0 ~ 2 047 special device( write available from 1025) www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 234 bit/word device t ype format range memo w s ddddd 0 ~ 127 re lay for step control w d ddddd 0 ~ 32767 data register w u dh.dd 0.00 ~ 3f.31 analog data register xgk - cpue : hh(0~1f) w n ddddd 0 ~ 21503 communication data register w z ddd 0 ~ 127 index register_128 words w t dddd 0 ~ 2047 timer current value regis ter w c dddd 0 ~ 2047 counter current value register w r ddddd 0 ~ 32767 w zr ddddd 0 ~ 32767 w ts dddd 0 ~ 2047 setup value w cs dddd 0 ~ 2047 setup value wiring d iagram: the following represents the view of hmi & plc. e mt 3 000 series com1 rs232 9 p d - sub fem ale com 3 rs232 9p d - sub fem ale rs232 9p d - sub male 2 rx 8 rx 3 t x d 3 tx 7 tx 2 r x d 5 gnd 5 gnd 5 gnd mt6000 /8000 series except mt6050i/mt8050i com1 rs232 9p d - sub fem ale com2 rs232 9p d - sub fem ale com3 rs232 9p d - sub m ale rs232 9 p d - sub male 2 rx 6 rx 8 rx 3 t x d 3 tx 4 tx 7 tx 2 r x d 5 gnd 5 gnd 5 gnd 5 gnd www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 235 mt6050i/mt8050i com1 rs232 9p d - sub fem ale rs232 9p d - sub male 9 rx 3 t x d 6 tx 2 r x d 5 gnd 5 gnd driver version : version date description v1. 4 0 mar / 1 0/20 11 a dd ed register s : p_bit, m_bit, l_bit, k_bit etc v 1.60 jun/18/2012 change the way to read/write s_bit. www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 236 ls mecapion metronix anypack hmi setting: parameters recommend ed option s notes plc type ls mecapion metronix anypack plc i/f rs232 baud rate 9600 data b its 8 parity none stop bits 1 plc s t a . n o. 0 device a ddress: bit/word device type format range memo b mx_l16bit ddd d ddd 0 ~ 9999915 md low 16bit b mx_h16bit ddd d ddd 0 ~ 9999915 md high 16bit dw md ddd d 0 ~ 9999 wiring d iagram: the following represents the view of hmi & plc. e mt 3 000 series com1 rs232 9p d - sub fem ale com 3 rs232 9p d - sub fem ale plc rs232 terminal 2 rx 8 rx 6 t x 3 tx 7 tx 5 r x 5 gnd 5 gnd 11 gnd circuit 12 gnd www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 237 mt6000 /8000 series except mt6050i/mt8050i com1 rs232 9p d - sub fem ale com2 rs232 9p d - sub fem ale com3 rs232 9p d - sub m ale plc rs232 terminal 2 rx 6 rx 8 rx 6 t x 3 tx 4 tx 7 tx 5 r x 5 gnd 5 gnd 5 gnd 11 gnd circuit 12 gnd mt6050i/mt8050i com1 rs232 9p d - sub fem ale plc rs232 terminal 9 rx 6 t x 6 tx 5 r x 5 gnd 11 gnd circuit 12 gnd driver version : version date description v 1. 0 0 jul/ 1 /20 08 www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 238 master - slave server for more information, please refer to user s manual ch28. hmi setting : parameters recommend ed option s notes plc type master - slave server plc i/f rs232 rs232/rs485 baud rate 115200 9600~115200 data b its 8 7,8 parity even none,even,odd,mark,space stop b its 1 1,2 hmi s t a . n o. 0 plc s t a . n o. 0 for mt500 hmi setting: parameters recommend ed option s notes plc type master (master - slave protocol) plc i/f rs232 baud rate 115200 38400, 115200 data b its 8 parity even stop b its 1 hmi s t a . n o. 0 plc s t a . n o. 0 parameter 1 mt500 plc id use plcaddr essview.exe to find plc id. www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 239 to connect hmi with mt500, mt500 has to be set as [slave]. plc setting: communication mode mt500 multiple hmi set slave . www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 240 device a ddress: bit/word mt500 mt8000 range memo b ms_rb rw_bit ddd: 0 ~ 4095 (h): 0 ~ f b ms_lb lb dddd:0 ~ 9999 w ms_rw rw ddd:0 ~ 65535 w ms_lw lw ddd:0 ~ 9999 driver version : version date description v1.00 dec/30/2008 driver released . www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 241 m emory map memory map protocol is similar to ibm 37 64r communication protocol. easybuil der reser ves 512 words of d ata memory to use with this protocol. easybuilder must update the valu es in these words. easybuilder uses the se words to display data and control parts status on screen. when touch actions are taken, data is sent to the other s on ce, and then update the memory in it. the hmi should always updat e the d ata memory. hmi setting: parameters recommend ed option s notes plc type memory map plc i/f rs232 rs232, rs485 4w, 2w rs232 default baud rate 115200 9600~115200 data b its 8 pari ty even even, odd, none stop b its 1 device a ddress: bit/word device t ype format range memo b mb dd d dh 0 ~ 4095f w mw dd d d 0 ~ 99 9 9 mb and mw share the same data storage . mw 0 = mb 00 0 00 ~ mb 00 0 0 f , mw 1 = mb 0 0 010 ~ mb 0 0 01 f wiring d iagram: the following represents the view of hmi & plc. e mt 3 000 series com1 rs232 9p d - sub fem ale com 3 rs232 9p d - sub fem ale hmi com1 rs 232 9p d - sub female 2 rx 8 rx 3 t x 3 tx 7 tx 2 r x 5 gnd 5 gnd 5 gnd www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 242 mt6000 /8000 series except mt6050i/mt8050i com1 rs232 9p d - sub fem ale com2 rs232 9p d - sub fem ale com3 rs232 9p d - sub m ale hmi com1 rs 232 9p d - sub female 2 rx 6 rx 8 rx 3 t x 3 tx 4 tx 7 tx 2 r x 5 gnd 5 gnd 5 gnd 5 gnd mt6050i/mt8050i com1 rs232 9p d - sub fem ale hmi com1 rs 232 9p d - sub femal e 9 rx 3 t x 6 tx 2 r x 5 gnd 5 gnd the following represents the view of hmi & plc. e mt 3 000 series com1 rs485 2 w 9p d - sub m ale com 3 rs485 2 w 9p d - sub m ale hmi com1 rs485 2 w 9p d - sub male 1 rx - 6 data - 1 rx - 2 rx+ 9 data+ 2 rx+ 5 gnd 5 gnd 5 gnd mt6000 /8000 series except mt6050i/mt8050i com1 rs485 2 w 9p d - sub m ale com 3 rs485 2 w 9p d - sub m ale hmi com1 rs485 2 w 9p d - sub male 1 rx - 6 data - 1 rx - 2 rx+ 9 data+ 2 rx+ 5 gnd 5 gnd 5 gnd www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 243 mt6050i/mt8050i com1 rs485 2 w 9 p d - sub fem ale com 3 rs485 2 w 9p d - sub fem ale hmi com1 rs485 2 w 9p d - sub female 1 rx - 7 data - 1 rx - 2 rx+ 8 data+ 2 rx+ 5 gnd 5 gnd 5 gnd the following represents the view of hmi & plc. e mt 3 000 series com1 rs485 4 w 9p d - sub m ale hmi com1 rs485 4w 9p d - sub male 1 rx - 3 tx - 2 r x + 4 tx+ 3 tx - 1 rx - 4 tx+ 2 rx+ 5 gnd 5 gnd mt6000 /8000 series except mt6050i/mt8050i com1 rs485 4 w 9p d - sub m ale hmi com1 rs485 4w 9p d - sub male 1 rx - 3 tx - 2 r x + 4 tx+ 3 tx - 1 rx - 4 tx+ 2 rx+ 5 gnd 5 gnd www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 244 mt6050i/mt8050i com1 rs485 4 w 9p d - sub fem ale hmi com1 rs485 4w 9p d - sub female 1 rx - 3 tx - 2 r x + 4 tx+ 3 tx - 1 rx - 4 tx+ 2 rx+ 5 gnd 5 gnd note: for memory map information, please refer to u ser s m anual c hap ter 31 memory map c ommunication . driver version : version date description v1.00 mar/19/2009 driver released . www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 245 m ikom mx series plc support series: mikom mx series plc web: http://www.mikom.com. cn/ hmi setting: parameters recommend ed option s notes plc type mikom mx series plc plc i/f rs232 rs232 /485/ethernet baud rate 19200 9600~115200 data b its even none ,even,odd parity 8 8 stop b its 1 1,2 plc s t a . n o. 1 0~31 online s imulator yes plc setting : port 0(rs232 setting ) www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 246 port 1(rs485 setting ) device a ddress: bit/word device t ype format range memo b y ddd 0~777 output relay b x ddd 0~777 input relay b m dddd 0~4095 auxiliary relay b sm ddd 0 - 511 special auxiliary relay b s dddd 0~1535 step relay b t ddd 0~511 timer relay b c ddd 0~511 counter relay w d ddddd 0~32767 data register w sd ddd 0~511 special data register w z ddd 0~255 indexed addressing register w t ddd 0~511 timer w c ddd 0~199 counter w u0 ddd 0~199 special module register w u1 ddd 0~199 special module register w u2 ddd 0~199 special module register w u3 ddd 0~199 special module register w u4 ddd 0~199 special module register w u5 ddd 0~199 special module register w u6 ddd 0~199 special module r egister w u7 ddd 0~199 special module register dw c - 32bit ddd 200~511 32 bit counter www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 247 wiring d iagram: the following represents the view of hmi & plc. e mt 3 000 series com1 rs232 9p d - sub fem ale com 3 rs232 9p d - sub fem ale rs232 8p mini - din male 2 rx 8 r x 3 t x 3 tx 7 tx 2 r x 5 gnd 5 gnd 5 gnd mt6000 /8000 series except mt6050i/mt8050i com1 rs232 9p d - sub fem ale com2 rs232 9p d - sub fem ale com3 rs232 9p d - sub m ale rs232 8p mini - din male 2 rx 6 rx 8 rx 3 t x 3 tx 4 tx 7 tx 2 r x 5 gnd 5 gnd 5 g nd 5 gnd mt6050i/mt8050i com1 rs232 9p d - sub fem ale rs232 8p mini - din male 9 rx 3 t x 6 tx 2 r x 5 gnd 5 gnd driver version : version date description v1.00 ma y / 3 /20 12 driver released . www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 248 mitsubishi a1s/a2n su pported s eries: m itsu bishi a1s /a2n website: http://www.mitsubishi - automation.com/ hmi setting: parameters recommend ed option s notes plc type mitsubishi a1s/a2n plc i/f rs 232 baud rate 9600 data b its 8 parity odd stop b its 1 plc s t a . n o. 0 device a ddress: bit/word device t ype format range memo b x hhhh 0 ~ ffff input relay b y hhhh 0 ~ ffff output relay b m ddddd 0 ~ 65535 auxiliary relay b b hhhh 0 ~ ffff b f ddddd 0 ~ 65535 w tv ddddd 0 ~ 6 5535 timer memory w cv ddddd 0 ~ 65535 counter memory w d ddddd 0 ~ 65535 data register w w hhhh 0 ~ ffff w r ddddd 0 ~ 65535 www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 249 wiring d iagram: use t he rs422 to rs232 plc programming cable (show n as follows) mitsubishi ans cpu the following repr esents the view of hmi & plc. e mt 3 000 series com1 rs232 9p d - sub fem ale plc programming converter mitsubishi rs422 25p d - sub male 2 r x tx tx+ 2 rx+ 3 tx rx rx+ 3 tx+ 5 gnd gnd dtr+ 4 dsr+ 7 rts cts gnd 7 gnd 8 cts rts tx - 15 rx - rx - 16 tx - dtr - 17 dsr - www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 250 mt6000 /8000 series except mt6050i/mt8050i com1 rs232 9p d - sub fem ale plc programming converter mitsubishi rs422 25p d - sub male 2 r x tx tx+ 2 rx+ 3 tx rx rx+ 3 tx+ 5 gnd gnd dtr+ 4 dsr+ 7 rts cts gnd 7 gnd 8 cts rts tx - 15 rx - rx - 1 6 tx - dtr - 17 dsr - driver version : version date description v1.00 sep/18/2009 driver released . www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 251 mitsubishi a2a/a2u/a2as/a2ush supported s eries: m itsubishi a2a , a2u,a2as, a2ush website: ht tp://www.mitsubishi - automation.com/ hmi setting: parameters recommend ed option s notes plc type mitsubishi a2a/a2u/a2as/a2ush plc i/f rs 232 baud rate 9600 data b its 8 parity odd stop b its 1 plc s t a . n o. 0 device a ddress: bit/word dev ice t ype format range memo b x hhhh 0 ~ 270f input relay b y hhhh 0 ~ 270f output relay b m dddd 0 ~ 9999 auxiliary relay b b hhhh 0 ~ ffff b f ddddd 0 ~ 65535 w tv ddd 0 ~ 255 timer memory w cv ddd 0 ~ 255 counter memory w d dddd 0 ~ 9999 data r egister w w hhhh 0 ~ ffff w r ddddd 0 ~ 65535 www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 252 wiring d iagram: use t he rs422 to rs232 plc programming cable (show n as follows) mitsubishi ans cpu the following represents the view of hmi & plc. e mt 3 000 series com1 rs232 9p d - sub fem ale plc progra mming converter mitsubishi rs422 25p d - sub male 2 r x tx tx+ 2 rx+ 3 tx rx rx+ 3 tx+ 5 gnd gnd dtr+ 4 dsr+ 7 rts cts gnd 7 gnd 8 cts rts tx - 15 rx - rx - 16 tx - dtr - 17 dsr - www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 253 mt6000 /8000 series except mt6050i/mt8050i com1 rs232 9p d - sub fem ale plc programming converter mitsubishi rs422 25p d - sub male 2 r x tx tx+ 2 rx+ 3 tx rx rx+ 3 tx+ 5 gnd gnd dtr+ 4 dsr+ 7 rts cts gnd 7 gnd 8 cts rts tx - 15 rx - rx - 16 tx - dtr - 17 dsr - driver version : version date description v1.00 aug/ 12/2009 driver released . www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 254 mitsubishi a3a/a3n/a1sh/a2sh supported s eries: m itsubishi a3a, a3n ,a1sh,a2sh website: http://www.mitsubishi - automation.com/ hmi setting: parameters recommend ed option s note s plc type mitsubishi a3a/a3n/a1sh/a2sh plc i/f rs 232 baud rate 9600 data b its 8 parity odd stop b its 1 plc s t a . n o. 0 note: this driver is not available for on - line simulation. device a ddress: bit/word device t ype format range memo b x hhhh 0 ~ ffff input relay b y hhhh 0 ~ ffff output relay b m ddddd 0 ~ 65535 auxiliary relay b b hhhh 0 ~ ffff b f ddddd 0 ~ 65535 w tv ddddd 0 ~ 65535 timer memory w cv ddddd 0 ~ 65535 counter memory w d ddddd 0 ~ 65535 data register w w hh hh 0 ~ ffff w r ddddd 0 ~ 65535 www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 255 wiring d iagram: use t he rs422 to rs232 plc programming cable (show n as follows) mitsubishi ans cpu the following represents the view of hmi & plc. e mt 3 000 series com1 rs232 9p d - sub fem ale plc programming converte r mitsubishi rs422 25p d - sub male 2 r x tx tx+ 2 rx+ 3 tx rx rx+ 3 tx+ 5 gnd gnd dtr+ 4 dsr+ 7 rts cts gnd 7 gnd 8 cts rts tx - 15 rx - rx - 16 tx - dtr - 17 dsr - www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 256 mt6000 /8000 series except mt6050i/mt8050i com1 rs232 9p d - sub fem ale plc progra mming converter mitsubishi rs422 25p d - sub male 2 r x tx tx+ 2 rx+ 3 tx rx rx+ 3 tx+ 5 gnd gnd dtr+ 4 dsr+ 7 rts cts gnd 7 gnd 8 cts rts tx - 15 rx - rx - 16 tx - dtr - 17 dsr - driver version : version date description v1.00 oct/20/2009 driver released . www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 257 mitsubishi a2us supported s eries: m itsubishi a2us website: http://www.mitsubishi - automation.com/ hmi setting: parameters recommend ed option s notes plc type mitsubishi a2us plc i/f r s 232 baud rate 9600 data b its 8 parity odd stop b its 1 plc s t a . n o. 0 device a ddress: bit/word device t ype format range memo b x hhhh 0 ~ 270f input relay b y hhhh 0 ~ 270f output relay b m dddd 0 ~ 9999 auxiliary relay w tv ddd 0 ~ 255 timer memory w cv ddd 0 ~ 255 counter memory w d dddd 0 ~ 9999 data register www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 258 wiring d iagram: use t he rs422 to rs232 plc programming cable (show n as follows) mitsubishi ans cpu the following represents the view of hmi & plc. e mt 3 000 series com1 rs232 9p d - sub fem ale plc programming converter mitsubishi rs422 25p d - sub male 2 r x tx tx+ 2 rx+ 3 tx rx rx+ 3 tx+ 5 gnd gnd dtr+ 4 dsr+ 7 rts cts gnd 7 gnd 8 cts rts tx - 15 rx - rx - 16 tx - dtr - 17 dsr - www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 259 mt6000 /8000 series except mt 6050i/mt8050i com1 rs232 9p d - sub fem ale plc programming converter mitsubishi rs422 25p d - sub male 2 r x tx tx+ 2 rx+ 3 tx rx rx+ 3 tx+ 5 gnd gnd dtr+ 4 dsr+ 7 rts cts gnd 7 gnd 8 cts rts tx - 15 rx - rx - 16 tx - dtr - 17 dsr - driver version : version date description v1.00 mar/20/2009 driver released . www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 2 60 mitsubishi aj71 supported s eries: mitsubishi a series plc with aj71c24 communication module using the computer link protocol. website: http://www.mitsubishi - automation.com hmi setting: parameters recommend ed option s notes plc type mitsubishi aj71 mitsubishi aj71 (ana/anu cpu) , mitsubishi aj71 (format 4) plc i/f rs485 4w rs485 4w, rs232 baud rate 19200 9600, 19200 data b its 8 8 parity even even, odd, none stop b its 1 1 plc s t a . n o. 0 plc setting: communication mode computer link protocol 9600, even, 8, 1 (default) mode s etting s witch format 1 parity c heck enable sum c heck enable device a ddress: bit/word device t ype format range memo b x hhhh 0 ~ ffff input bits b y hhhh 0 ~ ffff output bits b m ddddd 0 ~ 65535 internal relays b t ddddd 0 ~ 65535 b c ddddd 0 ~ 65535 b b hhhh 0 ~ ffff www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 261 bit/word device t ype format range memo b f ddddd 0 ~ 65535 w tv ddddd 0 ~ 65535 timer preset value w cv ddddd 0 ~ 65535 counter preset value w d ddddd 0 ~ 65535 data registers w w hhhh 0 ~ ffff w r ddddd 0 ~ 65535 wiring d iagram: the following represents the view of hmi & plc. aj71c24 rs422 e mt 3 000 series com1 rs485 4 w 9p d - sub m ale aj71c24 rs422 terminal 1 rx - sdb 2 r x + sda 3 tx - rdb 4 tx+ rda 5 gnd gnd mt6000 /8000 series except mt6050i/mt8050i com1 rs485 4 w 9p d - sub m ale aj71c24 rs422 terminal 1 rx - sdb 2 r x + sda 3 tx - rdb 4 tx+ rda 5 gnd gnd www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 262 mt 6050i/mt8050i com1 rs485 4 w 9p d - sub fem ale aj71c24 rs422 terminal 1 rx - sdb 2 r x + sda 3 tx - rdb 4 tx+ rda 5 gnd gnd the following represents the view of hmi & plc. a1sj71uc24 - r2 e mt 3 000 series com1 rs232 9p d - sub fem ale com 3 rs232 9p d - sub fem ale rs232 9p d - sub male 2 rx 8 rx 3 t x d 3 tx 7 tx 2 r x d 5 gnd 5 gnd 5 gnd 1 dcd circuit 4 dtr 6 dsr 7 rts circuit 8 cts www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 263 mt6000 /8000 series except mt6050i/mt8050i com1 rs232 9p d - sub fem ale com2 rs232 9p d - s ub fem ale com3 rs232 9p d - sub m ale rs232 9p d - sub male 2 rx 6 rx 8 rx 3 t x d 3 tx 4 tx 7 tx 2 r x d 5 gnd 5 gnd 5 gnd 5 gnd 1 dcd circuit 4 dtr 6 dsr 7 rts circuit 8 cts mt6050i/mt8050i com1 rs232 9p d - sub fem ale rs232 9p d - sub mal e 9 rx 3 t x d 6 tx 2 r x d 5 gnd 5 gnd 1 dcd circuit 4 dtr 6 dsr 7 rts circuit 8 cts driver version : version date description v1. 5 0 mar/11/2010 www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 264 mitsubishi aj71 (ana/anu cpu) supported s eries: mitsubishi aj71 (ana/anu cpu) website: http://www.mitsubishi - automation.com hmi setting: parameters recommend ed option s notes plc type mitsubishi aj71 (ana/anu cpu) plc i/f rs485 4w rs485 4w, rs232 baud rate 19200 9600, 19200 data b its 8 8 parity even even, odd, none stop b its 1 1 plc s t a . n o. 0 plc setting: communication mode computer link protocol 9600, even, 8, 1 (default) mode s etting s witch format 1 parity c heck enable sum c heck enable device a ddress: bit/w ord device t ype format range memo b x hhhh 0 ~ ffff input bits b y hhhh 0 ~ ffff output bits b m ddddd 0 ~ 65535 internal relays b t ddddd 0 ~ 65535 b c ddddd 0 ~ 65535 b b hhhh 0 ~ ffff b f ddddd 0 ~ 65535 w tv ddddd 0 ~ 65535 timer preset val ue w cv ddddd 0 ~ 65535 counter preset value w d ddddd 0 ~ 65535 data registers w w hhhh 0 ~ ffff w r ddddd 0 ~ 65535 www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 265 wiring d iagram: the following represents the view of hmi & plc. e mt 3 000 series com1 rs485 4 w 9p d - sub m ale rs422 terminal 1 rx - sdb 2 r x + sda 3 tx - rdb 4 tx+ rda 5 gnd gnd mt6000 /8000 series except mt6050i/mt8050i com1 rs485 4 w 9p d - sub m ale rs422 terminal 1 rx - sdb 2 r x + sda 3 tx - rdb 4 tx+ rda 5 gnd gnd mt6050i/mt8050i com1 rs485 4 w 9p d - sub fem ale rs422 terminal 1 rx - sdb 2 r x + sda 3 tx - rdb 4 tx+ rda 5 gnd gnd www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 266 the following represents the view of hmi & plc. e mt 3 000 series com1 rs232 9p d - sub fem ale com 3 rs232 9p d - sub fem ale rs232 9p d - sub ma le 2 rx 8 rx 3 t x d 3 tx 7 tx 2 r x d 5 gnd 5 gnd 5 gnd 1 dcd circuit 4 dtr 6 dsr 7 rts circuit 8 cts mt6000 /8000 series except mt6050i/mt8050i com1 rs232 9p d - sub fem ale com2 rs232 9p d - sub fem ale com3 rs232 9p d - sub m ale rs232 9p d - sub male 2 rx 6 rx 8 rx 3 t x d 3 tx 4 tx 7 tx 2 r x d 5 gnd 5 gnd 5 gnd 5 gnd 1 dcd circuit 4 dtr 6 dsr 7 rts circuit 8 cts www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 267 mt6050i/mt8050i com1 rs232 9p d - sub fem ale rs232 9p d - sub male 9 rx 3 t x d 6 tx 2 r x d 5 gnd 5 gnd 1 dcd circuit 4 dtr 6 dsr 7 rts circuit 8 cts driver version : version date description v1. 0 0 oct/31/2011 driver released. www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 268 mitsubishi aj71 (format 4) supported s eries: mitsubishi a series plc with aj71c24 communication module u sing the computer link protocol. website: http://www.mitsubishi - automation.com hmi setting: parameters recommend ed option s notes plc type mitsubishi aj71 (format 4) plc i/f rs485 4w rs485 4w, rs232 baud rate 19200 9600, 19200 data b its 8 8 parity even even, odd, none stop b its 1 1 plc s t a . n o. 0 plc setting: communication mode computer link protocol 9600, even, 8, 1 (default) mode s etting s witch format 4 parity c heck enable sum c heck e nable device a ddress: bit/word device t ype format range memo b x hhhh 0 ~ ffff input bits b y hhhh 0 ~ ffff output bits b m ddddd 0 ~ 65535 internal relays b t ddddd 0 ~ 65535 b c ddddd 0 ~ 65535 b b hhhh 0 ~ ffff b f ddddd 0 ~ 65535 w tv dddd d 0 ~ 65535 timer preset value w cv ddddd 0 ~ 65535 counter preset value w d ddddd 0 ~ 65535 data registers w w hhhh 0 ~ ffff w r ddddd 0 ~ 65535 www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 269 wiring d iagram: the following represents the view of hmi & plc. e mt 3 000 series com1 rs485 4 w 9p d - sub m ale aj71c24 rs422 terminal 1 rx - sdb 2 r x + sda 3 tx - rdb 4 tx+ rda 5 gnd gnd mt6000 /8000 series except mt6050i/mt8050i com1 rs485 4 w 9p d - sub m ale aj71c24 rs422 terminal 1 rx - sdb 2 r x + sda 3 tx - rdb 4 tx+ rda 5 gnd gnd mt6050i/mt8050i com1 rs485 4 w 9p d - sub fem ale aj71c24 rs422 terminal 1 rx - sdb 2 r x + sda 3 tx - rdb 4 tx+ rda 5 gnd gnd www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 270 the following represents the view of hmi & plc. a1sj71uc24 - r2 e mt 3 000 series com1 rs232 9p d - sub fem ale com 3 rs232 9p d - sub fem ale rs232 9p d - sub male 2 rx 8 rx 3 t x d 3 tx 7 tx 2 r x d 5 gnd 5 gnd 5 gnd 1 dcd circuit 4 dtr 6 dsr 7 rts circuit 8 cts mt6000 /8000 series except mt6050i/mt8050i com1 rs232 9p d - sub fem ale com2 rs232 9p d - sub fem ale com3 rs232 9p d - sub m ale rs232 9p d - sub male 2 rx 6 rx 8 rx 3 t x d 3 tx 4 tx 7 tx 2 r x d 5 gnd 5 gnd 5 gnd 5 gnd 1 dcd circuit 4 dtr 6 dsr 7 rts circuit 8 cts www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 271 mt6050i/mt8050i com1 rs232 9p d - sub fem ale rs232 9p d - sub male 9 rx 3 t x d 6 tx 2 r x d 5 gnd 5 gnd 1 dcd circuit 4 dtr 6 dsr 7 rts circuit 8 cts driver version : version date description v1. 0 0 mar/08/2010 www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 272 mitsubishi f930got server supported s eries: f930got general - purpose communication type 1 . hmi setting: parameters recommend ed option s notes plc type f930got server plc i/f rs232 baud rate 38400 9600, 115200 data b its 8 7 or 8 parity none even, odd, none stop b its 1 1 or 2 plc s t a . n o. 1 d evice a ddress: bit/word device t ype format range memo b rb dddd 0 ~ 2047 w rw ddddd 0 ~ 65535 note: in plc name drop - down menu dont select f930got server. p lease select local hmi, device t ype=rw. wiring d iagram: the following represents the view of hmi & plc. e mt 3 000 series com1 rs232 9p d - sub fem ale com 3 rs232 9p d - sub fem ale micro computer board rs232 fem ale 2 rx 8 rx 3 t d 3 tx 7 tx 2 r d 5 gnd 5 gnd 5 gnd www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 273 mt6000 /8000 series except mt6050i/mt8050i com1 rs232 9p d - sub fem ale c om2 rs232 9p d - sub fem ale com3 rs232 9p d - sub m ale micro computer board rs232 fem ale 2 rx 6 rx 8 rx 3 t d 3 tx 4 tx 7 tx 2 r d 5 gnd 5 gnd 5 gnd 5 gnd mt6050i/mt8050i com1 rs232 9p d - sub fem ale micro computer board rs232 fem ale 9 rx 3 t d 6 tx 2 r d 5 gnd 5 gnd protocol: read command: pc ? hmi 02 0 read rw0 1 word (2 bytes) stx = 0x02, 0 = read command, cr = 0x0d read address (hexadecimal) 0 ~ ffff = rw0 ~ 65535 size (hexadecim al) 2 ~ fe = 2 ~ 254 bytes = 1 ~ 127 word. size must be even. hmi ? pc (response) 02 cr 02 30 30 31 30 0d rw0 = 0x0010 = 16 read address size data1 www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 274 write command: pc ? hmi 02 1 ? pc (response) 06 ack = 0x06 driver version : version date description v1.00 aug/14/2009 d river released. read address size data1 data2 www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 275 mitsubishi fx0s/fx0n/fx1 s/fx1n/fx2 supported s eries: mitsubishi fx0s/fx0n/fx1s/ fx1n/ fx2 plc website: http://www.mitsubishi - automation.com hmi setting: parameters recommend ed option s notes plc type mitsubishi fx0s/fx0n/fx1s/ fx1n/fx2 plc i/f rs485 4w rs 232/rs485 baud rate 9600 9600 / 19200 /38400/ 57600/115200 data b its 7 7, 8 parity even even, odd, none stop b its 1 1 ,2 plc s t a . n o. 0 0 - 255 device a ddress: bit/word device t ype format range memo b x ooo 0 ~ 377 input relay b y ooo 0 ~ 377 output relay b m dddd 0 ~ 9999 auxiliary relay b t ddd 0 ~ 25 5 timer relay b c ddd 0 ~ 25 5 counter relay b sm dddd 8000 ~ 9999 special aux. relays b d_bit dddddd 0 ~ 999915 data register bit (d) b s dddd 0 ~ 4095 states w tv ddd 0 ~ 25 5 timer memory w cv ddd 0 ~ 199 counter memory w d dddd 0 ~ 9999 data register d w cv2 ddd 200 ~ 255 counter memory (d word) w sd dddd 8000 ~ 9999 special data register www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 276 wiring d iagram: the following represents the view of hmi & plc. e mt 3 000 series com1 rs485 4 w 9p d - sub m ale rs422 port 8p mini - din male 1 rx - 4 tx - 2 r x + 7 tx+ 3 tx - 1 rx - 4 tx+ 2 rx+ 5 gnd 3 gnd mt6000 /8000 series except mt6050i/mt8050i com1 rs485 4 w 9p d - sub m ale rs422 port 8p mini - din male 1 rx - 4 tx - 2 r x + 7 tx+ 3 tx - 1 rx - 4 tx+ 2 rx+ 5 gnd 3 gnd mt6050i/mt8050i com1 rs485 4 w 9p d - sub fem ale rs422 port 8p mini - din male 1 rx - 4 tx - 2 r x + 7 tx+ 3 tx - 1 rx - 4 tx+ 2 rx+ 5 gnd 3 gnd www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 277 the following represen ts the view of hmi & plc. . 9p d - sub to 25 p d - sub : e mt 3 000 series com1 rs485 4 w 9p d - sub m ale rs422 port 25 p mini - din male 1 rx - 16 tx d - 2 r x + 3 tx d + 3 tx - 15 rx d - 4 tx+ 2 rx d + 5 gnd 7 gnd circuit 4 dsr+ 8 gnd 13 +5v circuit 17 dsr - mt6000 /8000 series except mt6050i/mt8050i com1 rs485 4 w 9p d - sub m ale rs422 port 25 p mini - din male 1 rx - 16 tx d - 2 r x + 3 tx d + 3 tx - 15 rx d - 4 tx+ 2 rx d + 5 gnd 7 gnd circuit 4 dsr+ 8 gnd 13 +5v circuit 17 dsr - www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 278 mt6050i/mt8050i com1 rs485 4 w 9p d - sub fem ale rs422 port 25 p mini - din male 1 rx - 16 tx d - 2 r x + 3 tx d + 3 tx - 15 rx d - 4 tx+ 2 rx d + 5 gnd 7 gnd circuit 4 dsr+ 8 gnd 13 +5v circuit 17 dsr - driver version : version date description v1. 2 0 oct / 26 /20 11 www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 279 mitsubishi fx232/485bd supported s eries: m itsubishi fx0n/fx2/fx2n com for communication module bd fx2n - 485 - b d, fx2n - 232 - bd, fx1n - 485 - bd, fx1n - 232 - bd & fx3u - 485adp . website: http://www.mitsubishi - automation.com hmi setting: parameters recommend ed option s notes plc type mitsubishi fx232/485bd plc i/f rs 232/rs485 rs 232/rs485 2w/4w in accordance with the bd module baud rate 19200 9600 / 19200 /38400 data b its 7 7, 8 parity even even, odd, none stop b its 1 1 ,2 plc s t a . n o. 1 0 - 15 note: it is recommended to set turn around delay to 8. (for rs485 2w ) online s imulator yes extend address mode yes plc setting: communication mode must set plc station when u se ing bd module . register d8120 setting: set b9 and b8 of bfm#0 to 0 . fx2n - 485 - bd, fx1n - 485 - bd fx2n - 232 - bd, fx1n - 232 - bd www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 280 device a ddress: bit/word device t ype format range memo b x ooo 0 ~ 377 input relay b y ooo 0 ~ 377 output relay b m dddd 0 ~ 7 999 auxiliary relay b t ddd 0 ~ 511 timer relay b c ddd 0 ~ 25 5 counter relay b sm dddd 8000 ~ 9999 special auxiliary relay b d_bit ddddh 0 ~ 7999f data register bit b s dddd 0 ~ 4095 state relay w tv ddd 0 ~ 511 timer memory w cv ddd 0 ~ 199 count er memory w d dddd 0 ~ 7999 data register w cv2 ddd 20 0 ~ 25 5 counter memory (d word) w sd dddd 8000 ~ 9999 special data register w r ddddd 0 ~ 32767 extended register wiring d iagram: the following represents the view of hmi & plc. 9p d - sub to 9p d - su b: communication module rs232bd e mt 3 000 series com1 rs232 9p d - sub fem ale com 3 rs232 9p d - sub fem ale rs232 9p d - sub male 2 rx 8 rx 3 t x d 3 tx 7 tx 2 r x d 5 gnd 5 gnd 5 gnd www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 281 mt6000 /8000 series except mt6050i/mt8050i com1 rs232 9p d - sub fem al e com2 rs232 9p d - sub fem ale com3 rs232 9p d - sub m ale rs232 9p d - sub male 2 rx 6 rx 8 rx 3 t x d 3 tx 4 tx 7 tx 2 r x d 5 gnd 5 gnd 5 gnd 5 gnd mt6050i/mt8050i com1 rs232 9p d - sub fem ale rs232 9p d - sub male 9 rx 3 t x d 6 tx 2 r x d 5 gnd 5 gnd the following represents the view of hmi & plc. communication module rs485bd : rs485 4w e mt 3 000 series com1 rs485 4 w 9p d - sub m ale 485bd module 5p termanal 1 rx - sdb 2 r x + sda 3 tx - rdb 4 tx+ rda 5 gnd sg www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 282 mt6000 /8000 series except mt6050i/mt8050i com1 rs485 4 w 9p d - sub m ale 485bd module 5p termanal 1 rx - sdb 2 r x + sda 3 tx - rdb 4 tx+ rda 5 gnd sg mt6050i/mt8050i com1 rs485 4 w 9p d - sub fem ale 485bd module 5p termanal 1 rx - sdb 2 r x + sda 3 tx - rdb 4 tx+ rda 5 gnd sg the following represents the view of hmi & plc. communication module rs485bd : rs485 2w e mt 3 000 series com1 rs485 2 w 9p d - sub m ale com 3 rs485 2 w 9p d - sub m ale 485bd module 5p termanal 1 rx - 6 data - sdb circ uit rd b 2 rx+ 9 data+ sda circuit rda 5 gnd 5 gnd sg www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 283 mt6000 /8000 series except mt6050i/mt8050i com1 rs485 2 w 9p d - sub m ale com 3 rs485 2 w 9p d - sub m ale 485bd module 5p termanal 1 rx - 6 data - sdb circuit rdb 2 rx+ 9 data+ sda circu it rda 5 gnd 5 gnd sg mt6050i/mt8050i com1 rs485 2 w 9p d - sub fem ale com 3 rs485 2 w 9p d - sub fem ale 485bd module 5p termanal 1 rx - 7 data - sdb circuit rdb 2 rx+ 8 data+ sda circuit rda 5 gnd 5 gnd sg driver version : versi on date description v1. 4 0 jul / 26 /201 1 add ed registers: d_ b it and s. v1. 50 sep/10/2012 added register: r. www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 284 mitsubishi fx2n supported s eries: mitsubishi fx1n / fx2n series plc website http://www.mitsubi shi - automation.com hmi setting: parameters recommend ed option s notes plc type mitsubishi fx2n plc i/f rs485 4w rs 232/rs485 baud rate 19200 9600 / 19200 /38400 /57600/115200 data b its 7 parity even stop b its 1 plc s t a . n o. 0 online s imulat or yes extend address mode no device a ddress: bit/word device t ype format range memo b x ooo 0 ~ 377 input relay b y ooo 0 ~ 377 output relay b m dddd 0 ~ 7999 auxiliary relay b t ddd 0 ~ 25 5 timer relay b c ddd 0 ~ 25 5 counter relay b sm dddd 8000 ~ 9999 special auxiliary relay b d_bit dddddd 0 ~ 7999 15 data register bit (d) b s dddd 0 ~ 4095 state relay (s) w tv ddd 0 ~ 25 5 timer memory w cv ddd 0 ~ 199 counter memory w d dddd 0 ~ 7999 data register dw cv2 ddd 200 ~ 255 counter memory (d word ) w sd dddd 8000 ~ 9999 special data register www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 285 wiring d iagram: the following represents the view of hmi & plc. mitsubishi fx series e mt 3 000 series com1 rs485 4 w 9p d - sub m ale rs422 8p mini - din male 1 rx - 4 t x - 2 r x + 7 tx+ 3 tx - 1 rx - 4 tx+ 2 rx+ 5 gnd 3 gnd mt6000 /8000 series except mt6050i/mt8050i com1 rs485 4 w 9p d - sub m ale rs422 8p mini - din male 1 rx - 4 t x - 2 r x + 7 tx+ 3 tx - 1 rx - 4 tx+ 2 rx+ 5 gnd 3 gnd www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 286 mt6050i/mt8050i com1 rs485 4 w 9p d - sub fem ale rs422 8p mini - din male 1 rx - 4 t x - 2 r x + 7 tx+ 3 tx - 1 rx - 4 tx+ 2 rx+ 5 gnd 3 gnd driver version : version date description v1.60 sep/10/2009 www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 287 mitsubishi fx3u (ethernet) supported s eries: m itsubishi fx series, module: fx3u - ene t . website: http://www.mitsubishi - automation.com hmi setting: parameters recommend ed option s notes plc type mitsubishi fx3u (ethernet) plc i/f ethernet port n o. 5001(default) refer to module se tting plc s t a . n o. 0 (default) refer to module setting plc setting: fx3u - enet module setting: bef ore using ethernet module, us e gx developer / fx configurator - en to set the ethernet module, the fx3 u - enet module s etting steps are shown below . step 1. op en gx developer , select read from plc in online list. www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 288 step2. select fxcpu in plc series. step3. c onnect plc via serial port for setting ip address first . www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 289 step4. after finishing the plc settings, select tools/fx special function utility/fx c onfigurator - en . step5. select module 0 in ethernet module settings. ( if more than one module needed , pleas e set modules step by step ) www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 290 step6. in ethernet operational setting s, select the related parameters and ip address and then press end to fi nish setting . step7. in ethernet open settings, pres s end after setting the parameters below . (the first protocol means using gx develop er to communicate with module, t he max. fixed buffer communication preocedure is 4 units.) www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 291 or www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 292 step 8. after setting the parameters of plc, restart for ethernet communication. device a ddress: bit/word device type format range memo b x ooo 0 ~ 571 input b y ooo 0 ~ 571 output relay b m dddd 0 ~ 7 999 internal relay b t ddd 0 ~ 511 timer contacts b c ddd 0 ~ 255 counter contacts b sm dddd 8000 ~ 8511 special int. relays b d_bit ddddddd 0 ~ 1799915 data register bit access b s dddd 0 ~ 4095 step relays w tv ddd 0 ~ 511 timer value w cv ddd 0 ~ 199 counter value w d dddd 0 ~ 7999 data registers w cv2 ddd 200 ~255 counter value w sd dddd 8000 ~ 8511 special data registers w r ddddd 0 ~ 32767 file register www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 293 wiring d iagram: direct connect (crossover cable): hmi rj45 male wire color wire color plc rj45 male 1 tx+ white/orange white/green 3 rx+ 2 tx - orange green 6 rx - 3 rx+ white/green white/orange 1 tx+ 4 bd4+ blue blue 4 bd4+ 5 bd4 - white/blue white/blue 5 bd4 - 6 rx - green orange 2 tx - 7 bd3+ white/brown white/brown 7 bd3+ 8 bd3 - brown brown 8 bd3 - through a hub: hmi rj45 male wi re color wire color plc rj45 male 1 tx+ white/orange white/orange 1 tx+ 2 tx - orange orange 2 tx - 3 rx+ white/green white/green 3 rx+ 4 bd4+ blue blue 4 bd4+ 5 bd4 - white/blue white/blue 5 bd4 - 6 rx - green green 6 rx - 7 bd3+ white/brown white/brown 7 bd3+ 8 bd3 - brown brown 8 bd3 - driver version : version date description v1.00 feb/12/2009 driver released . www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 294 mitsubishi fx3u/fx3g supported s eries : mitsubishi fx 3u/fx3uc /fx3g . website: http:// www.mitsubishi - automation.com hmi setting: parameters recommend ed option s notes plc type mitsubishi fx3u/fx3g plc i/f rs485 4w rs 232/rs485 2w/4w baud rate 38400 9600 / 19200 data b its 7 parity even stop b its 1 plc s t a . n o. 0 does not apply to this protocol onli ne s imulator yes (9600 baud rate only) extend address mode no device a ddress: bit/word device t ype format range memo b x ooo 0 ~ 764 input relay b y ooo 0 ~ 764 output relay b m dddd 0 ~ 7 999 auxiliary relay b t ddd 0 ~ 511 tim er relay (t) b c ddd 0 ~ 255 counter relay (c) b sm dddd 8000 ~ 9999 special relay (m) b d _b it dddddd 0 ~ 799915 data register bit (d) b s dddd 0 ~ 4095 state relay (s) w tv ddd 0 ~ 511 timer memory (t) w cv ddd 0 ~ 199 counter memory (c) w d dddd 0 ~ 7999 data register (d) dw cv2 ddd 200 ~ 255 counter memory (d word) w sd dddd 800 0 ~ 9999 special data register (d) w r ddddd 0 ~ 32767 extended register (r) w z d 0 ~ 7 index register www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 295 wiring d iagram: the following represents the view of hmi & plc . e mt 3 000 series com1 rs485 4 w 9p d - sub m ale rs422 8p mini - din male 1 rx - 4 t x - 2 r x + 7 tx+ 3 tx - 1 rx - 4 tx+ 2 rx+ 5 gnd 3 gnd mt6000 /8000 series except mt6050i/mt8050i com1 rs485 4 w 9p d - sub m ale rs422 8p mini - din male 1 rx - 4 t x - 2 r x + 7 tx+ 3 tx - 1 rx - 4 tx+ 2 rx+ 5 gnd 3 gnd mt6050i/mt8050i com1 rs485 4 w 9p d - sub fem ale rs422 8p mini - din male 1 rx - 4 t x - 2 r x + 7 tx+ 3 tx - 1 rx - 4 tx+ 2 rx+ 5 gnd 3 gnd www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 296 driver version : version dat e description v1. 71 nov/15/2010 www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 297 mitsubishi melsec - q/l - ascii mode (ethernet) supported s eries: m itsubishi q series (q03ude, q04udeh, q06udeh, q10udeh, q13udeh, q20udeh, q26udeh), m itsubishi l series (l02, l26 - bt), melsec - q /l protocol application to cp u of ethernet interface or ethernet module. website: http://www.mitsubishi - automation.com hmi setting: parameters recommend ed option s notes plc type mitsubishi melsec - q/l - ascii mode (ethernet) plc i/f ethernet p ort n o. set identically to the plc setting advice d to set port no. to 4999 parameter 1 netw orking no. ( set identically to plc setting) 0~255 q13udeh has to be set to 0 plc s t a . n o. set identically to the plc setting 255 q13udeh has to be set to 255 plc setting: mitsubishi q /l series ethernet module setting: note : if using qj71e71 module, please refer to mitsu bishi qj71e71 connection guide. www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 298 1. click [ plc parameter ]. 2. [ built - in ethernet port ] . 3. click [ open settings ] and then set the i p address and communication data code 4. set the mc protocol - tcp port no. 1387 (hex) and in e asy b uilder, tcp port is 4999 (dec). www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 299 note: in e asy b uilder , please fill in [n etwork n o. ] in parameter 1 as plc setting. for example below , the network n o. is 2. s et to 2 for parameter 1 in e asy b uilder . www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 300 device a ddress: bit/word device t ype format range memo b sm dddd 0 ~ 2047 special relay b x hhhh 0 ~ 1 fff input relay b y hhhh 0 ~ 1 fff output relay b m ddddd 0 ~ 61439 internal relay b l ddddd 0 ~ 32767 latch relay b f ddddd 0 ~ 32767 annunciator b v ddddd 0 ~ 32767 edge relay b b hhhh 0 ~ efff link relay b ts ddddd 0 ~ 25471 timer contact b tc ddddd 0 ~ 25471 timer coil b ss ddddd 0 ~ 25471 retentive timer contact b sc ddddd 0 ~ 25471 retentive timer coil b cs ddddd 0 ~ 25471 counter contact b cc ddddd 0 ~ 25471 counter coil b sb hhhh 0 ~ 7fff special link relay b s dddd 0 ~ 8191 step relay b dx hhhh 0 ~ 1fff direct inpu t b dy hhhh 0 ~ 1fff direct output b d_bit ddd dddh 0 ~ 999999 f data register bit b sd_bit ddddh 0 ~ 2047f special register bit b zr_bit dddddd h 0 ~ 999999 f file register bit b r_bit dddddh 0 ~ 32767f file register bit b sw_bit hhhh 0 ~ 7fff special l ink register bit b w_bit hhhhhhh 0 ~ 3fd7fff link register bit w sd dddd 0 ~ 2047 special register w d ddddd d 0 ~ 999999 data register w w hhhhhh 0 ~ 3fd7ff link register w tn ddddd 0 ~ 25471 timer current value w sn ddddd 0 ~ 25471 retentive timer c urrent value w cn ddddd 0 ~ 25471 counter current value w sw hhh 0 ~ 7ff special link register w z dd 0 ~ 20 index register w r ddddd 0 ~ 32767 file register w zr dddddd 0 ~ 999999 file register www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 301 note: e ach m o del of cpu is different, it is recommended to refer to mitsubishi melsec - q manual device list. wiring d iagram: direct connect (crossover cable): hmi rj45 male wire color wire color plc rj45 male 1 tx+ white/orange white/green 3 rx+ 2 tx - orange green 6 rx - 3 rx+ white/green white/orange 1 tx+ 4 bd4+ blue blue 4 bd4+ 5 bd4 - white/blue white/blue 5 bd4 - 6 rx - green orange 2 tx - 7 bd3+ white/brown white/brown 7 bd3+ 8 bd3 - brown brown 8 bd3 - through a hub: hmi rj45 male wire color wire color plc rj45 male 1 tx+ white/orange white/oran ge 1 tx+ 2 tx - orange orange 2 tx - 3 rx+ white/green white/green 3 rx+ 4 bd4+ blue blue 4 bd4+ 5 bd4 - white/blue white/blue 5 bd4 - 6 rx - green green 6 rx - 7 bd3+ white/brown white/brown 7 bd3+ 8 bd3 - brown brown 8 bd3 - driver version : version date description v 1. 0 0 jul/10 /201 2 driver released . www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 302 mitsubishi melsec - q/l - binary mode (ethernet) supported s eries: m itsubishi q series (q03ude, q04udeh, q06udeh, q10udeh, q1 3 udeh, q20udeh, q26udeh), m itsubishi l series (l02, l26 - bt) , melsec - q /l protoco l application to cpu of ethernet interface or ethernet module. website: http://www.mitsubishi - automation.com hmi setting: parameters recommend ed option s notes plc type mitsubishi melsec - q/l - binary m ode (ethernet) plc i/f ethernet p ort n o. set identically to the plc setting advice d to set port no. to 4999 parameter 1 netw orking no. ( set identically to plc setting) 0~255 q13udeh has to be set to 0 plc s t a . n o. set identically to the plc setting 255 q13udeh has to be set to 255 plc setting: mitsubishi q /l series ethernet module setting: note : if using qj71e71 module, please refer to mitsu bishi qj71e71 connection guide. www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 303 1. click [ plc parameter ]. 2. [ built - in ethernet port ] . 3. click [ open settings ] and then set the ip address and communication data code 4. set the mc protocol - tcp port no. 1387 (hex) and in e asy b uilder , tcp port is 4999 (dec). note: in e asy b uilder , please fill in [n etwork n o. ] in parameter 1 as plc setting. for example below , the netwo rk n o. is 2 . www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 304 s et to 2 for parameter 1 in e asy b uilder . device a ddress: bit/word device t ype format range memo b sm dddd 0 ~ 2047 special relay b x hhhh 0 ~ 1 fff input relay b y hhhh 0 ~ 1fff output relay b m ddddd 0 ~ 61439 internal relay b l ddddd 0 ~ 32767 latch relay b f ddddd 0 ~ 32767 annunciator b v ddddd 0 ~ 32767 edge relay b b hhhh 0 ~ efff link relay b ts ddddd 0 ~ 2 5471 timer contact b tc ddddd 0 ~ 25471 time r coil b ss ddddd 0 ~ 25471 retentive timer contact b sc ddddd 0 ~ 25471 retentive timer coil b cs ddddd 0 ~ 25471 counter contact b cc ddddd 0 ~ 25471 counter coil b sb hhhh 0 ~ 7 fff special link relay b s dddd 0 ~ 8191 step relay b dx hhhh 0 ~ 1ff f direct input b dy hhhh 0 ~ 1fff direct output b d_bit dddddddh 0 ~ 4184063 f data register bit www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 305 bit/word device t ype format range memo b sd_bit ddddh 0 ~ 2047 f special register bit b zr_bit hhhhhhh 0 ~ 3 fd 7 fff file register bit b r_bit dddddh 0 ~ 32767 f file register bit b sw_bit hhhh 0 ~ 7 fff special link register bit b w_bit hhhhhhh 0 ~ 3 fd 7 fff link register bit w sd dddd 0 ~ 2047 special register w d ddddddd 0 ~ 4184063 data register w w hhhhhh 0 ~ 3 fd 7 ff link register w tn ddddd 0 ~ 25471 timer current value w sn ddddd 0 ~ 25471 retentive timer current value w cn ddddd 0 ~ 25471 counter current value w sw hhh 0 ~ 7 ff special link register w z dd 0 ~ 20 index register w r ddddd 0 ~ 32767 file register w zr hhhhhh 0 ~ 3fd7ff file register note: e ach m o del of cpu is different, it is recommended to refer to mitsubishi melsec - q manual device list. wiring d iagram: direct connect (crossover cable): hmi rj45 male wire color wire color plc rj45 male 1 tx+ white/orange white/green 3 rx+ 2 tx - orange green 6 rx - 3 rx+ white/green wh ite/orange 1 tx+ 4 bd4+ blue blue 4 bd4+ 5 bd4 - white/blue white/blue 5 bd4 - 6 rx - green orange 2 tx - 7 bd3+ white/brown white/brown 7 bd3+ 8 bd3 - brown brown 8 bd3 - www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 306 through a hub: hmi rj45 male wire color wire color plc rj45 male 1 tx+ white /orange white/orange 1 tx+ 2 tx - orange orange 2 tx - 3 rx+ white/green white/green 3 rx+ 4 bd4+ blue blue 4 bd4+ 5 bd4 - white/blue white/blue 5 bd4 - 6 rx - green green 6 rx - 7 bd3+ white/brown white/brown 7 bd3+ 8 bd3 - brown brown 8 bd3 - drive r version : version date description v 1. 30 jan/ 14 /2011 www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 307 mitsubishi mr j3 a website : http://www.mitsubishi - automation.com hmi setting : parameters recommended options notes plc type mitsubishi mr j3 a plc i/f rs485 4w rs232/rs485 baud rate 9600 9600~115200 parity even data bits 8 stop bits 1 plc sta. no. 0 0~31 device address : bit/word device type format range memo b eip dd 0 ~ 31 external input pin status read** b eop dd 0 ~ 31 ext ernal output pin status read** w pa dd 1 ~ 19 basic setting w pb dd 1 ~ 45 gain / filter setting w pc dd 1 ~ 50 extension setting w pd dd 1 ~ 30 input / output setting w status dd 0 ~ 17 amplifier status w alarm d 0 ~ 6 alarm w alarm_t d 0 ~ 6 alarm time ( hour ) w mode d 1 ~ 4 write only, mode setting * w speed d 0 ~ 1 write only, set current speed * w acc d 0 ~ 1 write only, set acceleration * w rotation d 0 ~ 1 write only, rotation direction * w end d 0 ~ 1 write only, end * w m_dist d 0 ~ 1 write only, moving distance * w rot_p d 0 ~ 1 write only, rotation position * w p_start d 0 ~ 1 write only, start positioning * note : 1. * represents the write - only registers. the usage of this kind of registers is to run jog mode and positioning mode. 2.** rep resents the read - only registers. www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 308 eip: eop: www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 309 how to use easybuilder8000/easy builderpro to run jog and positioning mode * jog mode to run jog mode, please follow the steps listed sequentially : (1) set jog mode (2) set rotation speed (3) set acceleration (4) set f orward / reverse rotation direction (5) end the following shows how to run the steps above using macro in easybuilder8000/easy builderpro . on the editing window of easybuilder8000/easy builderpro , the write address of speed is set to local hmi lw0 (the ad dress can be user - defined), and set acc (acceleration) to lw1. to run jog mode, the communication with the device must be continuous which only allows an interval less than 0.5 seconds, otherwise the motor will be locked. therefore, in this example, on ly one register pa_1 is set to read device value. macro demonstration: a. start macro macro_command main() short speed short acc short mode mode = 1 // this represents jog mode. setdata(mode, "mitsubishi mr j3 a", mode, 1, 1) // set driver mode to jog . getdata(speed, "local hmi", lw, 0, 1) // save lw0 value to speed . setdata(speed, "mitsubishi mr j3 a", speed, 0, 1) // set motor operating speed. www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 310 getdata(acc, "local hmi", lw, 1, 1) // setdata(acc, "mitsubishi mr j3 a", acc, 0, 1) // set motor acce leration. short motion motion = 0x0801 // special code, see note 1. setdata(motion, "mitsubishi mr j3 a", rotation, 0, 1) // rotate. end macro_command note 1 . original factory manual: b. end macro macro_command main() short stop stop = 1 // see note 2 . setdata(stop, "mitsubishi mr j3 a", end, 1, 1) end macro_command note 2 . original factory manual: www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 311 *positioning mode on the editing window of easybuilder8000/easy builderpro , the write address of speed is set to local hmi lw2 (the add ress can be user - defined), and set acc (acceleration) to lw3, move distance to lw4 (dw format). macro demonstration: macro_command main() short mode mode = 0x2 // p ositioning mode setdata(mode, "mitsubishi mr j3 a", mode, 1, 1) short speed getdata( speed, "local hmi", lw, 2, 1) setdata(speed, "mitsubishi mr j3 a", speed, 0, 1) short acc getdata(acc, "local hmi", lw, 3, 1) setdata(acc, "mitsubishi mr j3 a", acc, 0, 1) short dist getdata(dist, "local hmi", lw, 4, 1) setdata(dist, "mitsubishi mr j3 a" , m_dist, 0, 1) short rot_p rot_p = 1 // set to 0: forward rotation 1: reverse rotation setdata(rot_p, "mitsubishi mr j3 a", rot_p, 0, 1) short rotat rotat = 1 // see note 3 . www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 312 setdata(rotat, "mitsubishi mr j3 a", rotation, 0, 1) setdata(rot_p, "mitsubishi mr j3 a", p_start, 0, 1) // start positioning. end macro_command note 3. original factory manual wiring diagram : the following represents the view of hmi & plc. e mt 3 000 series com1 rs485 4 w 9p d - sub m ale cn3 rs4 85 4w rj45 male 1 rx - 4 t x - 2 r x + 5 tx+ 3 tx - 6 rx - 4 tx+ 3 rx+ 5 gnd 7 gnd mt6000 /8000 series except mt6050i/mt8050i com1 rs485 4 w 9p d - sub m ale cn3 rs485 4w rj45 male 1 rx - 4 t x - 2 r x + 5 tx+ 3 tx - 6 rx - 4 tx+ 3 rx+ 5 gnd 7 gnd www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 313 mt605 0i/mt8050i com1 rs485 4 w 9p d - sub fem ale cn3 rs485 4w rj45 male 1 rx - 4 t x - 2 r x + 5 tx+ 3 tx - 6 rx - 4 tx+ 3 rx+ 5 gnd 7 gnd driver version : version date description v 1. 00 sep/01/2011 driver released. v1.10 jan/1 3/2012 added regi ster: eip and eop. www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 314 mitsubishi mr - mq100 (ethernet) supported s eries: m itsubishi mr - mq100 - ethernet website: http://www.mitsubishi - automation.com hmi setting: parameters recommend ed option s notes plc type mitsubishi mr - mq100 (ethernet) plc i/f ethernet port no. set identically to the plc setting advice d to set port no. to 4999 parameter1 1 network n o. plc st a . no. 255 plc setting: www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 315 1. click [ basic setting ] . 2. [built - in ethernet port s etting ] . 3. click [open s etting ] and then set the ip address and communication data code . 4. set the mc p rotocol - tcp port no. ( hex) device a ddress: bit/word device t ype format range memo b sm dddd 0 ~ 2255 special relay b x hhhh 0 ~ 1 fff input b y hhhh 0 ~ 1 fff output b m ddddd 0 ~ 61439 internal relay b f ddddd 0 ~ 32767 annunciator b b hhhh 0 ~ efff link relay b d_ b it dddddddh 0 ~ 4184063f w sd dddd 0 ~ 2255 special register w d ddddddd 0 ~ 4184063 data register w w hhhhhh 0 ~ 3fd7ff link re gister w # ddddd 0 ~ 12287 motion register note: ddd: decimal, hhh: hexadecimal, ooo: octal. wiring d iagram: direct connect (crossover cable): hmi rj45 male wire color wire color plc rj45 male 1 tx+ white/orange white/green 3 rx+ 2 tx - orange green 6 rx - 3 rx+ white/green white/orange 1 tx+ 4 bd4+ blue blue 4 bd4+ 5 bd4 - white/blue white/blue 5 bd4 - 6 rx - green orange 2 tx - 7 bd3+ white/brown white/brown 7 bd3+ 8 bd3 - brown brown 8 bd3 - www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 316 through a hub: hmi rj45 male wire color wire color p lc rj45 male 1 tx+ white/orange white/orange 1 tx+ 2 tx - orange orange 2 tx - 3 rx+ white/green white/green 3 rx+ 4 bd4+ blue blue 4 bd4+ 5 bd4 - white/blue white/blue 5 bd4 - 6 rx - green green 6 rx - 7 bd3+ white/brown white/brown 7 bd3+ 8 bd3 - brown brown 8 bd3 - driver version : version date description v 1. 10 jun / 08 /2011 add ed register: d_bit www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 317 mitsubishi q00/q00uj/q01/qj71 supported s eries: mitsubishi q series plc with qj71c24 communication module, q00, q00j, q00uj, q01, q02h, q06h, q12h, q2 5h, q12ph, q25ph cpu port. website: http://www.mitsubishi - automation.com hmi setting: parameters recommend ed option s notes plc type mitsubishi q00/q00uj/q01/qj71 plc i/f rs232 rs485 4w, rs232 bau d rate 9600 9600~115200 data bits 8 parity odd stop bits 1 plc s t a . n o. 0 online s imulator yes extend address mode no plc setting: q00, q01 cpu port setting: 1. in gx dev eloper plc data list click [ plc parameter ]. 2. in plc parameter go to [ serial ] page. 3. select [ use serial communication ]. 4. set [ transmission speed ] to 9600~115200. 5. select [ sum check ]. 6. set [ transmission wait time ] to 10ms. 7. permit [ run write setting ]. 8. click [ end ] to close the dialog. 9. write the plc parameter to plc. 10. r eset plc, the parameter will be active d . www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 318 qj71 setting: www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 319 device address: bit/word device t ype format range memo b x hhhh 0 ~ 1fff input relay b y hhhh 0 ~ 1fff output relay b m dddd 0 ~ 8191 internal relay b l dddd 0 ~ 8191 latch relay b f dddd 0 ~ 2047 an nunciator b v dddd 0 ~ 2047 edge relay b b hhhh 0 ~ 1fff link relay b tc dddd 0 ~ 2047 timer coil b ss dddd 0 ~ 2047 retentive timer contact b sc dddd 0 ~ 2047 retentive timer coil b cs dddd 0 ~ 1023 counter contact b cc dddd 0 ~ 1023 counter coil b sb hhh 0 ~ 7ff special link relay b s dddd 0 ~ 8191 step relay b dx hhhh 0 ~ 1fff direct input b dy hhhh 0 ~ 1fff direct output b ts dddd 0 ~ 2047 timer contact b sm dddd 0 ~ 2047 b d_bit dddddh 0 ~ 12287f w w hhhh 0 ~ 2fff link register w tn d ddd 0 ~ 2047 timer current value w sn dddd 0 ~ 2047 retentive timer current value w cn dddd 0 ~ 1023 counter current value w r ddddd 0 ~ 32767 file register w sw hhh 0 ~ 7ff special link register w z dd 0 ~ 15 index register w zr hhhh 0 ~ ffff file r egister w d ddddd 0 ~ 12287 data register w sd dddd 0 ~ 2047 www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 320 wiring d iagram: the following represents the view of hmi & plc. qj71c24 ch.2 rs422 terminal e mt 3 000 series com1 rs485 4 w 9p d - sub m ale qj71c24 ch.2 rs422 terminal 1 rx - sdb 2 r x + sda 3 tx - rdb 4 tx+ rda 5 gnd gnd mt6000 /8000 series except mt6050i/mt8050i com1 rs485 4 w 9p d - sub m ale qj71c24 ch.2 rs422 terminal 1 rx - sdb 2 r x + sda 3 tx - rdb 4 tx+ rda 5 gnd gnd www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 321 mt6050i/mt8050i com1 rs485 4 w 9p d - sub fem ale qj71c24 ch.2 rs422 terminal 1 rx - sdb 2 r x + sda 3 tx - rdb 4 tx+ rda 5 gnd gnd the following represents the view of hmi & plc. qj71c24 ch.2 rs232 e mt 3 000 series com1 rs232 9p d - sub fem ale com 3 rs232 9p d - sub fem a le qj71c24 ch.1 rs232 9p d - sub male 2 rx 8 rx 3 t x d 3 tx 7 tx 2 r x d 5 gnd 5 gnd 5 gnd 1 dcd circuit 4 dtr 6 dsr 7 rts circuit 8 cts www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 322 mt6000 /8000 series except mt6050i/mt8050i com1 rs232 9p d - sub fem ale com2 rs232 9p d - sub fem a le com3 rs232 9p d - sub m ale qj71c24 ch.1 rs232 9p d - sub male 2 rx 6 rx 8 rx 3 t x d 3 tx 4 tx 7 tx 2 r x d 5 gnd 5 gnd 5 gnd 5 gnd 1 dcd circuit 4 dtr 6 dsr 7 rts circuit 8 cts mt6050i/mt8050i com1 rs232 9p d - sub fem ale qj71c24 ch.1 rs232 9p d - sub male 9 rx 3 t x d 6 tx 2 r x d 5 gnd 5 gnd 1 dcd circuit 4 dtr 6 dsr 7 rts circuit 8 cts www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 323 the following represents the view of hmi & plc. 9p d - sub to 6 p m ini - din : q00, q01 cpu port rs232 e mt 3 000 series com1 rs232 9p d - sub fem ale com 3 rs232 9p d - sub fem ale rs232 6 p m ini - din male 2 rx 8 rx 3 t xd 3 tx 7 tx 4 r xd 5 gnd 5 gnd 5 gnd mt6000 /8000 series except mt6050i/mt8050i com1 rs232 9p d - sub fem ale com2 rs232 9p d - sub fem ale com3 rs232 9p d - sub m ale rs2 32 6 p m ini - din male 2 rx 6 rx 8 rx 3 t xd 3 tx 4 tx 7 tx 4 r xd 5 gnd 5 gnd 5 gnd 5 gnd mt6050i/mt8050i com1 rs232 9p d - sub fem ale rs232 6 p m ini - din male 9 rx 3 t xd 6 tx 4 r xd 5 gnd 5 gnd www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 324 the following represents the view of hmi & plc. 9p d - sub to 6 p m ini - din : q00uj cpu port rs232 e mt 3 000 series com1 rs232 9p d - sub fem ale com 3 rs232 9p d - sub fem ale rs232 6 p m ini - din male 2 rx 8 rx 3 t xd 3 tx 7 tx 4 r xd 5 gnd 5 gnd 5 gnd 1 rts circuit 6 cts mt6000 /8000 series except mt6050i/mt8050i com1 rs232 9p d - sub fem ale com2 rs232 9p d - sub fem ale com3 rs232 9p d - sub m ale rs232 6 p m ini - din male 2 rx 6 rx 8 rx 3 t xd 3 tx 4 tx 7 tx 4 r xd 5 gnd 5 gnd 5 gnd 5 gnd 1 rts circuit 6 cts mt6050i/mt8050i com 1 rs232 9p d - sub fem ale rs232 6 p m ini - din male 9 rx 3 t xd 6 tx 4 r xd 5 gnd 5 gnd 1 rts circuit 6 cts www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 325 driver version : version date description v1. 8 0 jun / 0 8 /201 1 added register: d_bit v1. 90 sep/23/2011 f ixed bit communication inco rrect. www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 326 mitsubishi q00j supported s eries: m itsubishi q 00j cpu hmi setting: parameters recommend ed option s notes plc type mitsubishi q00j plc i/f rs232 cpu port baud rate 115200 9600,19200,38400, 57600,115200 data bits 8 parity odd stop bits 1 plc s t a . n o. online s imulator no extend address mode no device a ddress: bit/word device t ype format range memo b sm dddd 0 ~ 1023 b x hhh 0 ~ 7 ff b y hhh 0 ~ 7ff b m dddd 0 ~ 8191 b l dddd 0 ~ 2047 b f dddd 0 ~ 1023 b v dddd 0 ~ 1 023 b b hhh 0 ~ 7ff b sb hhh 0 ~ 3ff b d_bit dddd d h 0 ~ 11135f w sd dddd 0 ~ 1023 w d ddddd 0 ~ 11135 w w hhh 0 ~ 7ff w sw hhh 0 ~ 3ff w z d 0 ~ 9 w c ddd 0 ~ 511 w t ddd 0 ~ 511 www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 327 wiring d iagram: the following represents the view of hm i & plc. 9p d - sub to 6 p m ini - din : q00 cpu port rs232 e mt 3 000 series com1 rs232 9p d - sub fem ale com 3 rs232 9p d - sub fem ale rs232 6 p m ini - din male 2 rx 8 rx 3 t xd 3 tx 7 tx 4 r xd 5 gnd 5 gnd 5 gnd mt6000 /8000 series except mt6050i/mt8050i com 1 rs232 9p d - sub fem ale com2 rs232 9p d - sub fem ale com3 rs232 9p d - sub m ale rs232 6 p m ini - din male 2 rx 6 rx 8 rx 3 t xd 3 tx 4 tx 7 tx 4 r xd 5 gnd 5 gnd 5 gnd 5 gnd mt6050i/mt8050i com1 rs232 9p d - sub fem ale rs232 6 p m ini - din male 9 rx 3 t xd 6 tx 4 r xd 5 gnd 5 gnd mt8 - mitsubishi - q - 3m ca ble can connect mt8000 with mitsubishi q series directly . driver version : version date description v1. 2 0 jun / 0 8/20 11 add ed register d_bit www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 328 mitsubishi q00u/q01u/q02u/qnud/qnudh supported s erie s: m itsubishi q00u, q01u, q 02u, q03ud, q04udh, q06udh, q10udh, q13udh, q20udh, q26udh , q00uj cpu . hmi setting: parameters recommend ed option s notes plc type mitsubishi q00u/q01u/q02u/qnud/qnudh plc i/f rs232 rs485 4w, rs232 cpu port direct connect baud rate 11 5200 115200 only 9600,19200,38400,57600,115200 for q00uj, only 9600 is available data b its 8 parity odd stop b its 1 plc s t a . n o. no online s imulator no extend address mode no device a ddress: bit/word device t ype format range memo b sm dddd 0 ~ 2047 b x hhhh 0 ~ 1 fff input relay b y hhhh 0 ~ 1 fff output relay b m dddd 0 ~ 8191 internal relay b l dddd 0 ~ 8191 latch relay b f dddd 0 ~ 2047 annunciator b v dddd 0 ~ 2047 edge relay b b hhhh 0 ~ 1 fff link relay b sb hhh 0 ~ 7ff special link relay b d_bit dddddh 0 ~ 12287f w sd dddd 0 ~ 2047 w d ddddd 0 ~ 12287 data register w w hhhh 0 ~ 1 fff link register w sw hhh 0 ~ 7ff special link register w z dd 0 ~ 1 9 index register w r ddddd 0 ~ 32767 w c dddd 0 ~ 1023 counter c urrent value www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 329 bit/word device t ype format range memo w t dddd 0 ~ 2047 timer current value note: e asy b uilder doesnt support mitsubishi q02u cpu to do on - line simulation on pc. when using q02u driver, hmi needs 10 seconds to initia te p lc q02u driver. before the completion of initiation , it is recommended not to wri t e data to plc, this could cause plc no response incorrect wiring or data could cause plc to be locked. if plc is locked, please restart plc or reinstall plc module. wiring d iagram: the following represents the view of hmi & plc. 9p d - sub to 6 p m ini - din : q0 2 cpu port rs232 e mt 3 000 series com1 rs232 9p d - sub fem ale com 3 rs232 9p d - sub fem ale rs232 6 p m ini - din male 2 rx 8 rx 3 t xd 3 tx 7 tx 4 r xd 5 gnd 5 gnd 5 gnd 1 rts circuit 6 cts mt6000 /8000 series except mt6050i/mt8050i com1 rs232 9p d - sub fem ale com2 rs232 9p d - sub fem ale c om3 rs232 9p d - sub m ale rs232 6 p m ini - din male 2 rx 6 rx 8 rx 3 t xd 3 tx 4 tx 7 tx 4 r xd 5 gnd 5 gnd 5 gnd 5 gnd 1 rts circuit 6 cts www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 330 mt6050i/mt8050i com1 rs232 9p d - sub fem ale rs232 6 p m ini - din male 9 rx 3 t xd 6 tx 4 r xd 5 gnd 5 gnd 1 rts circuit 6 cts driver version : version date description v1. 6 0 jun / 0 8/20 11 add ed register d_bit www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 331 mitsubishi q00uj/qnu/qnud/qnudh/qnudeh/l (mini usb) supported s eries: m itsubishi q00uj, q00u, q01u, q02u, q03ude, q03ud, q04udeh, q04udh, q06udeh, q06udh, q10udeh, q10udh, q13udeh, q13udh, q20udeh, q20udh, q26udeh, q26udh , l02, l26 - bt usb port . hmi setting: parameters recommend ed option s notes plc type mitsubishi q00uj/qnu/qnud/qnudh/qnudeh/l (mini usb) plc i/f usb cpu port dir ect connect device a ddress: bit/word device t ype format range memo b sm dddd 0 ~ 2047 b x hhhh 0 ~ 1 fff input relay b y hhhh 0 ~ 1 fff output relay b m dddd 0 ~ 8191 internal relay b l dddd 0 ~ 8191 latch relay b f dddd 0 ~ 2047 annunciator b v dd dd 0 ~ 2047 edge relay b b hhhh 0 ~ 1 fff link relay b sb hhh 0 ~ 7ff special link relay b d_bit dddddh 0 ~ 12287f w sd dddd 0 ~ 2047 w d ddddd 0 ~ 12287 data register w w hhhh 0 ~ 1 fff link register w sw hhh 0 ~ 7ff special link register w z dd 0 ~ 1 9 index register w r ddddd 0 ~ 32767 w c dddd 0 ~ 1023 counter current value w t dddd 0 ~ 2047 timer current value www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 332 note: e asy b uilder doesnt support mitsubishi q02u cpu to do on - line simulation on pc. when using q02u driver, hmi needs 10 seconds to initia te p lc q02u driver. before the completion of initiation , it is recommended not to wri t e data to plc, this could cause plc no response incorrect wiring or data could cause plc to be locked. if plc is locked, please resta rt plc or reinstall plc module. driver version : version date description v1. 3 0 jun / 0 8/20 11 add ed register d_bit www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 333 mitsubishi q02/02h suppo rted s eries; m itsubishi q02/ q02h cpu port. website: http://www.mitsubishi - automation.com hmi setting: parameters recommend ed option s notes plc type mitsubishi q02/02h plc i/f rs232 rs485 4w, rs232 baud rate 115200 115200 on ly data b its 8 parity odd stop b its 1 plc s t a . n o. 0 online s imulator yes extend address mode no broadcast command no device a ddress: bit/word device t ype format range memo b x hhhh 0 ~ 1 fff input relay b y hhhh 0 ~ 1 fff output relay b m dddd 0 ~ 8191 internal relay b l dddd 0 ~ 8191 latch relay b f dddd 0 ~ 2047 annunciator b v dddd 0 ~ 2047 edge relay b b hhhh 0 ~ 1 fff link relay b tc dddd 0 ~ 2047 timer coil b ss dddd 0 ~ 2047 retentive timer contact b sc dddd 0 ~ 2047 reten tive timer coil b cs dddd 0 ~ 1023 counter contact b cc dddd 0 ~ 1023 counter coil b sb hhh 0 ~ 7 ff special link relay b s dddd 0 ~ 8191 step relay www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 334 bit/word device t ype format range memo b dx hhhh 0 ~ 1 fff direct input b dy hhhh 0 ~ 1 fff direct output b ts dddd 0 ~ 2047 timer contact b d_bit dddddh 0 ~ 12287f w w hhhh 0 ~ 1 fff link register w tn dddd 0 ~ 2047 timer current value w sn dddd 0 ~ 2047 retentive timer current value w cn dddd 0 ~ 1023 counter current value w r ddddd 0 ~ 32767 file register w sw hhh 0 ~ 7 ff special link register w z dd 0 ~ 15 index register w zr hhhh 0 ~ ffff file register w d ddddd 0 ~ 12287 data register wiring d iagram: the following represents the view of hmi & plc. 9p d - sub to 6 p m ini - din : q0 2 cpu port rs232 e mt 3 000 series com1 rs232 9p d - sub fem ale com 3 rs232 9p d - sub fem ale rs232 6 p m ini - din male 2 rx 8 rx 3 t xd 3 tx 7 tx 4 r xd 5 gnd 5 gnd 5 gnd 1 rts circuit 6 cts www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 335 mt6000 /8000 series except mt6050i/mt8050i com1 rs232 9p d - sub fem ale com2 rs232 9p d - sub fem ale com3 rs23 2 9p d - sub m ale rs232 6 p m ini - din male 2 rx 6 rx 8 rx 3 t xd 3 tx 4 tx 7 tx 4 r xd 5 gnd 5 gnd 5 gnd 5 gnd 1 rts circuit 6 cts mt6050i/mt8050i com1 rs232 9p d - sub fem ale rs232 6 p m ini - din male 9 rx 3 t xd 6 tx 4 r xd 5 gnd 5 gnd 1 rts circuit 6 cts driver version : version date description v1. 6 0 jun / 0 8/20 11 add ed register d_bit www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 336 mitsubishi q06h supported s eries: mitsubishi q0 6 h cpu port. website: http://www.mitsu bishi - automation.com hmi setting: parameters recommend ed option s notes plc type mitsubishi q06h plc i/f rs232 rs485 4w, rs232 baud rate 115200 115200 only data b its 8 parity odd stop b its 1 plc s t a . n o. 0 online s imulator yes extend a ddress mode no broadcast command no device a ddress: bit/word device t ype format range memo b x hhhh 0 ~ 1 fff input relay b y hhhh 0 ~ 1 fff output relay b m dddd 0 ~ 8191 internal relay b l dddd 0 ~ 8191 latch relay b f dddd 0 ~ 2047 annunciator b v dddd 0 ~ 2047 edge relay b b hhhh 0 ~ 1 fff link relay b tc dddd 0 ~ 2047 timer coil b ss dddd 0 ~ 2047 retentive timer contact b sc dddd 0 ~ 2047 retentive timer coil b cs dddd 0 ~ 1023 counter contact b cc dddd 0 ~ 1023 counter coil b sb hhh 0 ~ 7 ff special link relay b s dddd 0 ~ 8191 step relay www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 337 bit/word device t ype format range memo b dx hhhh 0 ~ 1 fff direct input b dy hhhh 0 ~ 1 fff direct output b ts dddd 0 ~ 2047 timer contact b d_bit dddddh 0 ~ 12287f w w hhhh 0 ~ 1 fff link register w tn dddd 0 ~ 2047 timer current value w sn dddd 0 ~ 2047 retentive timer current value w cn dddd 0 ~ 1023 counter current value w r ddddd 0 ~ 32767 file register w sw hhh 0 ~ 7 ff special link register w z dd 0 ~ 15 index register w zr hhhh 0 ~ ffff file register w d ddddd 0 ~ 12287 dat a register wiring d iagram: the following represents the view of hmi & plc. 9p d - sub to 6 p m ini - din : q0 2 cpu port rs232 e mt 3 000 series com1 rs232 9p d - sub fem ale com 3 rs232 9p d - sub fem ale rs232 6 p m ini - din male 2 rx 8 rx 3 t xd 3 tx 7 tx 4 r xd 5 gnd 5 gnd 5 gnd 1 rts circuit 6 cts www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 338 mt6000 /8000 series except mt6050i/mt8050i com1 rs232 9p d - sub fem ale com2 rs232 9p d - sub fem ale com3 rs232 9p d - sub m ale rs232 6 p m ini - din male 2 rx 6 rx 8 rx 3 t xd 3 tx 4 tx 7 tx 4 r xd 5 gnd 5 gnd 5 gnd 5 gnd 1 rts circuit 6 cts mt6050i/mt8050i com1 rs232 9p d - sub fem ale rs232 6 p m ini - din male 9 rx 3 t xd 6 tx 4 r xd 5 gnd 5 gnd 1 rts circuit 6 cts driver version : version date description v1. 6 0 jun / 0 8/20 11 add ed register d_bit www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 339 mitsubishi qj71e71 (ethernet) supported s eries ; mitsubishi q type, melsec - q series plc (q00j, q00, q01, q02, q02h, q06h, q12h, q25h, q12ph, q25ph) qj71e71 - 100 ethernet module . website: http://www.mitsubishi - automation.com hmi setting: parameters recommend ed option s notes plc type mitsubishi qj71e71 (ethernet) plc i/f ethernet port n o. 5002 plc s t a . n o. 2 1~99 note: mitsubishi qj7 1e71 only supports plc network n o. 1. if pl c network n o. is not 1, please use mistsubishi melsec - q(ethernet) driver and fill in the network n o. in parameter 1. please refer to mistsubishi melsec - q(ethernet) for further information. plc setting: qj71e71 - 100 ethernet module settings: 1. use usb or rs 232 of q - cpu for setting plc parameters. www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 340 2. click [ operational setting s] to set ip information. www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 341 3. select ethernet (2.0) for communicating with hmi. 4. click [ o pen settings ] to set the system. www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 342 5. press [ end ] to finish settings. 6. restart plc software a nd select [read from plc], select [ qcpu(qmode) ] and press [ ok ] . 7. in [ pc s ide i/f ethernet board setting] set network no. a nd station n o. (station n o.1 is pc s tation n o. not ethernet module station no. , range d from 2~64, the network n o. can not be the same as that of pc ) www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 343 8. select ethernet module in plc side i/f to set qj71e71 ip address.(i p address = network parameter ip address) 9. for other station , c lick [ other station(single network) ] for setting [ check at communication time ] and [ retry times ] . 10. after finishing the settings above, click [ connection test ] for testing the com munication and sending the plc program. www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 344 device a ddress: bit/word device t ype format range memo b sm dddd 0 ~ 2047 b x hhhh 0 ~ 1 fff input relay b y hhhh 0 ~ 1 fff output relay b m dddd 0 ~ 8191 internal relay b l dddd 0 ~ 8191 latch relay b f dddd 0 ~ 2047 annunciator b v dddd 0 ~ 2047 edge relay b b hhhh 0 ~ 1 fff link relay b ts dddd 0 ~ 2047 b tc dddd 0 ~ 2047 b ss dddd 0 ~ 2047 b sc dddd 0 ~ 2047 b cs dddd 0 ~ 1023 b cc dddd 0 ~ 1023 b sb hhh 0 ~ 7ff special link relay b s dddd 0 ~ 8191 b dx hhhh 0 ~ 1 fff direct input b dy hhhh 0 ~ 1 fff direct output b d_bit dddddh 0 ~ 12287f w sd dddd 0 ~ 2047 w d ddddd 0 ~ 1 2287 data register w w hhhh 0 ~ 1fff link register w tn dddd 0 ~ 2047 w sn dddd 0 ~ 2047 w cn dddd 0 ~ 1023 w sw hhh 0 ~ 7ff special link register w z dd 0 ~ 15 index register w r ddddd 0 ~ 32767 file register w zr hhhhh 0 ~ fe7ff file register www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 345 wiring d iagram: direct connect (crossover cable): hmi rj45 male wire color wire color plc rj45 male 1 tx+ white/orange white/green 3 rx+ 2 tx - orange green 6 rx - 3 rx+ white/green whit e/orange 1 tx+ 4 bd4+ blue blue 4 bd4+ 5 bd4 - white/blue white/blue 5 bd4 - 6 rx - green orange 2 tx - 7 bd3+ white/brown white/brown 7 bd3+ 8 bd3 - brown brown 8 bd3 - through a hub: hmi rj45 male wire color wire color plc rj45 male 1 tx+ white/or ange white/orange 1 tx+ 2 tx - orange orange 2 tx - 3 rx+ white/green white/green 3 rx+ 4 bd4+ blue blue 4 bd4+ 5 bd4 - white/blue white/blue 5 bd4 - 6 rx - green green 6 rx - 7 bd3+ white/brown white/brown 7 bd3+ 8 bd3 - brown brown 8 bd3 - driver v ersion : version date description v 2 . 2 0 jun / 0 8/20 11 add ed register: d_bit www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 346 m odbus ascii supported s eries: modbus ascii controller website: http://www.m odbus.org hmi setting: parameters recommend ed option s notes pl c type modbus ascii plc i/f rs 485 rs 232/rs485 baud rate 9600 9600 / 19200 /38400/ 57600/115200 data b its 8 7, 8 parity even even, odd, none stop b its 1 1 ,2 plc s t a . n o. 1 0 - 255 online s imulator yes broadcast command yes extend address mode yes plc setting: communication mode modbus ascii protocol device a ddress: bit/word dev ice t ype format range memo b 1x ddddd 1 ~ 65535 input bit (read only) b 0x ddddd 1 ~ 65535 output bit b 3x_bit ddddddd 1 00 ~ 65535 15 input register bit (read only) b 4x_bit ddddddd 1 00 ~ 65535 15 output register bit w 3x ddddd 1 ~ 65535 input register (read only) w 4x ddddd 1 ~ 65535 output register w 6x ddddd 1 ~ 65535 www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 347 modbus rtu function code: 0x 0x01 read coil 0x05 write single coil 1x 0x02 read discrete input n/a for write operation 3x 0x04 read input register n/a for write operation 4x 0x03 read holding register 0x10 write multiple register s 3xbit is equivalent to 3x 4xbit is equivalent to 4x wirin g d iagram: the following represents the view of hmi & plc. modbus ascii controller : rs232 e mt 3 000 series com1 rs232 9p d - sub fem ale com 3 rs232 9p d - sub fem ale rs232 9p d - sub female 2 rx 8 rx t x d 3 tx 7 tx r x d 5 gnd 5 gnd gnd rts circuit cts mt6000 /8000 series except mt6050i/mt8050i com1 rs232 9p d - sub fem ale com2 rs232 9p d - sub fem ale com3 rs232 9p d - sub m ale rs232 9p d - sub female 2 rx 6 rx 8 rx t x d 3 tx 4 tx 7 tx r x d 5 gnd 5 gnd 5 gnd gnd rts circuit cts www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 348 mt6050i/mt8050i com1 rs232 9p d - sub fem ale rs232 9p d - sub female 9 rx t x d 6 tx r x d 5 gnd gnd rts circuit cts the following represents the view of hmi & plc. modbus ascii controller : rs485 4w e mt 3 000 series com1 rs485 4 w 9 p d - sub m ale rs 485 4w 9p d - sub male 1 rx - tx - 2 r x + tx+ 3 tx - rx - 4 tx+ rx+ 5 gnd gnd mt6000 /8000 series except mt6050i/mt8050i com1 rs485 4 w 9p d - sub m ale rs 485 4w 9p d - sub male 1 rx - tx - 2 r x + tx+ 3 tx - rx - 4 tx+ rx+ 5 gnd gnd www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 349 mt6050i/mt8050i com1 rs485 4 w 9p d - sub fem ale rs 485 4w 9p d - sub female 1 rx - tx - 2 r x + tx+ 3 tx - rx - 4 tx+ rx+ 5 gnd gnd the following represents the view of hmi & plc. modbus ascii controll er : rs485 2w e mt 3 000 series com1 rs485 2 w 9p d - sub m ale com 3 rs485 2 w 9p d - sub m ale rs 485 2w 9p d - sub male 1 rx - 6 data - d - 2 rx+ 9 data+ d+ 5 gnd 5 gnd gnd mt6000 /8000 series except mt6050i/mt8050i com1 rs485 2 w 9p d - sub m ale com 3 rs485 2 w 9p d - sub m ale rs 485 2w 9p d - sub male 1 rx - 6 data - d - 2 rx+ 9 data+ d+ 5 gnd 5 gnd gnd www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 350 mt6050i/mt8050i com1 rs485 2 w 9p d - sub fem ale com 3 rs485 2 w 9p d - sub fem ale rs 485 2w 9p d - sub female 1 rx - 7 data - d - 2 rx+ 8 data+ d+ 5 gnd 5 gnd gnd driver version : version date description v1.40 apr/17/2009 www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 351 modbus ascii server hmi setting: parameters recommend ed option s notes plc type modbus ascii server plc i/f rs232 rs232, rs485 baud rate 9600 9600~115200 data b its 8 7, 8 parity even even, odd, none stop b its 1 1 plc s t a . n o. 1 1 - 31 hmi modbus station no. online simulator yes extend address mode no broadcast command no plc setting: communication mode modbus ascii protocol device a ddress: bit/word device t ype format range memo b lb dddd 0 ~ 9998 mapping to 0x/1x 1 ~ 9999 w lw dddd 0 ~ 9998 mapping to 3x/4x 1 ~ 9999 w rw ddddd 0 ~ 55536 mapping to 3x/4x 10000 ~ 65536 lb0 = 0x0001, lb1 = 0x0002, lw0 = 3x0001, lw1 = 3x0002 modbus rtu s erver doesnt suppor t function c ode 06( preset single register), please use function code 16(0x10, preset multiple register s ). modbus server function code : 0x 0x01 read coil 0x05 write single coil 0x_multi_coils 0x01 read coil 0x0f write mul tiple coil s 1x 0x02 read discrete input n/a for write operation 3x 0x04 read input register n/a for write operation 4x 0x03 read holding register 0x10 write multiple register s www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 352 wiring d iagram: the following represents th e view of hmi & plc. rs232 e mt 3 000 series com1 rs232 9p d - sub fem ale com 3 rs232 9p d - sub fem ale rs232 9p d - sub female 2 rx 8 rx t x d 3 tx 7 tx r x d 5 gnd 5 gnd gnd rts circuit cts mt6000 /8000 series except mt6050i/mt8050i com1 r s232 9p d - sub fem ale com2 rs232 9p d - sub fem ale com3 rs232 9p d - sub m ale rs232 9p d - sub female 2 rx 6 rx 8 rx t x d 3 tx 4 tx 7 tx r x d 5 gnd 5 gnd 5 gnd gnd rts circuit cts mt6050i/mt8050i com1 rs232 9p d - sub fem ale rs232 9p d - sub fem ale 9 rx t x d 6 tx r x d 5 gnd gnd rts circuit cts www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 353 the following represents the view of hmi & plc. rs485 4w e mt 3 000 series com1 rs485 4 w 9p d - sub m ale rs 485 4w 9p d - sub male 1 rx - tx - 2 r x + tx+ 3 tx - rx - 4 tx+ rx + 5 gnd gnd mt6000 /8000 series except mt6050i/mt8050i com1 rs485 4 w 9p d - sub m ale rs 485 4w 9p d - sub male 1 rx - tx - 2 r x + tx+ 3 tx - rx - 4 tx+ rx+ 5 gnd gnd mt6050i/mt8050i com1 rs485 4 w 9p d - sub fem ale rs 485 4w 9p d - sub female 1 rx - tx - 2 r x + tx+ 3 tx - rx - 4 tx+ rx+ 5 gnd gnd www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 354 the following represents the view of hmi & plc. rs485 2w e mt 3 000 series com1 rs485 2 w 9p d - sub m ale com 3 rs485 2 w 9p d - sub m ale rs 485 2w 9p d - sub male 1 rx - 6 d ata - d - 2 rx+ 9 data+ d+ 5 gnd 5 gnd gnd mt6000 /8000 series except mt6050i/mt8050i com1 rs485 2 w 9p d - sub m ale com 3 rs485 2 w 9p d - sub m ale rs 485 2w 9p d - sub male 1 rx - 6 data - d - 2 rx+ 9 data+ d+ 5 gnd 5 gnd gnd mt6050i/mt8050 i com1 rs485 2 w 9p d - sub fem ale com 3 rs485 2 w 9p d - sub fem ale rs 485 2w 9p d - sub male 1 rx - 7 data - d - 2 rx+ 8 data+ d+ 5 gnd 5 gnd gnd note: setting more than one modbus ascii server in hmi device list is of no effect. driver version : ver sion date description v1.00 feb/19 /200 9 driver released www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 355 m odbus rtu supported s eries : modbus rtu controller website : http://www.m odbus.org hmi setting: parameters recommend ed option s notes plc type modbus rtu p lc i/f rs 485 rs 232/rs485 baud rate 9600 9600 ~ 115200 data b its 8 7, 8 parity even even, odd, none stop b its 1 1 , 2 plc s t a . n o. 1 0 - 255 online s imulator yes broadcast command yes extend address mode yes plc setting: communication mode modb us rtu protocol device a ddress: bit/word device t ype format range memo b 0x ddddd 1 ~ 65535 output bit b 1x ddddd 1 ~ 65535 input bit (read only) b 3x_bit ddddddd 1 00 ~ 65535 15 input register bit (read only) b 4x_bit ddddddd 1 00 ~ 65535 15 output regi ster bit b 6 x_bit ddddddd 1 00 ~ 65535 15 output register bit b 0x _multi_coils ddddd 1 ~ 65535 write m ultiple c oils w 3x ddddd 1 ~ 65535 input register (read only) w 4x ddddd 1 ~ 65535 output register dw 5x ddddd 1 ~ 65535 4x double word swap w 6x dddd d 1 ~ 65535 4x single word write w 4x_32bit * ddddd 1 ~ 65535 output register 4x_32bit will only read / write 2 words for each package , for continuous addresses, it will be divided into several packages. www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 356 note: address type 5x is mapping to hold reg. t he communication protocol of 5x is almost the same as 4x except that 5x swaps d ouble word . if 4x contains the following information : address 1 2 3 4 5 6 ... data in word 0x1 0x2 0x3 0x4 0x5 0x6 data 0x20001 0x40003 0x60005 for 5x, it will be: add ress 1 2 3 4 5 6 ... data in word 0x2 0x1 0x4 0x3 0x6 0x5 data 0x10002 0x30004 0x50006 modbus rtu function code: 0x 0x01 read coil 0x05 write single coil 0x_multi_coils 0x01 read coil 0x0f write multiple coil s 1x 0x02 read discrete input n/a for write operation 3x 0x04 read input register n/a for write operation 4x 0x03 read holding register 0x10 write multiple register s 5x 0x03 read holding register 0x10 write multiple register s ( n ote: reverse word order in double word format) 3xbit is equivalent to 3x 4xbit is equivalent to 4x 6x 0x03 read holding register 0x06 write single register ( n ote: 6x is limited to device of one word only) www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 357 wiring d iagram: the follo wing represents the view of hmi & plc. modbus rtu controller : rs232 e mt 3 000 series com1 rs232 9p d - sub fem ale com 3 rs232 9p d - sub fem ale rs232 9p d - sub female 2 rx 8 rx t x d 3 tx 7 tx r x d 5 gnd 5 gnd gnd rts circuit cts mt6000 /8000 series except mt6050i/mt8050i com1 rs232 9p d - sub fem ale com2 rs232 9p d - sub fem ale com3 rs232 9p d - sub m ale rs232 9p d - sub female 2 rx 6 rx 8 rx t x d 3 tx 4 tx 7 tx r x d 5 gnd 5 gnd 5 gnd gnd rts circuit cts mt6050i/mt8050i com1 rs232 9p d - sub fem ale rs232 9p d - sub female 9 rx t x d 6 tx r x d 5 gnd gnd rts circuit cts www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 358 the following represents the view of hmi & plc. modbus rtu controller : rs485 4w e mt 3 000 series com1 rs485 4 w 9p d - sub m ale rs 485 4w 9 p d - sub male 1 rx - tx - 2 r x + tx+ 3 tx - rx - 4 tx+ rx+ 5 gnd gnd mt6000 /8000 series except mt6050i/mt8050i com1 rs485 4 w 9p d - sub m ale rs 485 4w 9p d - sub male 1 rx - tx - 2 r x + tx+ 3 tx - rx - 4 tx+ rx+ 5 gnd gnd mt6050i/mt8050i com1 rs485 4 w 9p d - sub fem ale rs 485 4w 9p d - sub female 1 rx - tx - 2 r x + tx+ 3 tx - rx - 4 tx+ rx+ 5 gnd gnd www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 359 the following represents the view of hmi & plc. modbus rtu controller : rs485 2w e mt 3 000 serie s com1 rs485 2 w 9p d - sub m ale com 3 rs485 2 w 9p d - sub m ale rs 485 2w 9p d - sub male 1 rx - 6 data - d - 2 rx+ 9 data+ d+ 5 gnd 5 gnd gnd mt6000 /8000 series except mt6050i/mt8050i com1 rs485 2 w 9p d - sub m ale com 3 rs485 2 w 9p d - sub m ale rs 485 2w 9 p d - sub male 1 rx - 6 data - d - 2 rx+ 9 data+ d+ 5 gnd 5 gnd gnd mt6050i/mt8050i com1 rs485 2 w 9p d - sub fem ale com 3 rs485 2 w 9p d - sub fem ale rs 485 2w 9p d - sub female 1 rx - 7 data - d - 2 rx+ 8 data+ d+ 5 gnd 5 gnd gnd driver ver sion : version date description v1.90 may/05/2010 fixed whe n receiving data over 8 bytes from modbus rtu , lw - 9570 fails to calculate correctly. www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 360 modbus rtu (0x/1x range adjustable) supported s eries : modbus rtu controller website : http://www.modbus.org hmi setting: parameters recommend ed options notes plc t ype modbus rtu (0x/1x range adjustable) plc i/f rs 485 rs 232/rs485 baud r at e 9600 9600 ~115200 data b its 8 7, 8 parity even even, odd, none stop b its 1 1 ,2 plc s t a . n o. 1 0 - 255 online s imulator yes extend a ddress m ode yes plc setting: communication m ode modbus rtu protocol device a ddress: bit/word device t ype format range memo b 0x ddddd 1 ~ 65535 output bit b 1x ddddd 1 ~ 65535 input bit (read on ly) b 3x_bit ddddddd 1 00 ~ 65535 15 input register bit (read only) b 4x_bit ddddddd 1 00 ~ 65535 15 output register bit b 6 x_bit ddddddd 1 00 ~ 65535 15 output register bit b 0x _multi_coils ddddd 1 ~ 65535 write m ultiple c oils w 3x ddddd 1 ~ 65535 input re gister (read only) w 4x ddddd 1 ~ 65535 output register dw 5x ddddd 1 ~ 65535 4x double word swap w 6x ddddd 1 ~ 65535 4x single word write w 4x_32bit * ddddd 1 ~ 65535 output register 4x_32bit will only read / write 2 words for each package , for conti nuous addresses, it will be divided into several packages. www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 361 note: address type 5x is mapping to hold reg. the communication protocol of 5x is almost the same as 4x except that 5x swap s double words. if 4x contains the following information: address 1 2 3 4 5 6 ... data in word 0x1 0x2 0x3 0x4 0x5 0x6 data 0x20001 0x40003 0x60005 for 5x, i t will be : address 1 2 3 4 5 6 ... data in word 0x2 0x1 0x4 0x3 0x6 0x5 data 0x10002 0x30004 0x50006 modbus rtu function code: 0x 0x01 read coil 0x05 write single coil 0x_multi_coils 0x01 read coil 0x0f write multiple coil s 1x 0x02 read discrete input n/a for writing operation 3x 0x04 read input register n/a for writing operation 4x 0x03 read h olding register 0x10 write multiple register s 5x 0x03 read holding register 0x10 write multiple register s (note: reverse word order in double words format) 3xbit is equivalent to 3x 4xbit is equivalent to 4x 6x 0x03 read holding regis ter 0x06 w rite single register (note: 6x is limited to device of one word only) www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 362 setting i nstructions : 1. go to [system parameter settings] click [new] to add a new device - modbus rtu (0x 1x range adjustable) as shown below: 2. after adding modbus rtu (0x 1x range adjustable) driver, [add address range limit] button will be enabled as below. users can set maximum read/write command size here. ? max.read - command size (words): pull down to select plc reading range. ? max.write - command size (words): pull down to select plc writing range. note: setting [add address range limit] is enabled only when bit address is not a multiple of 16bit. www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 363 3. click [add address range limit] button, users can define 0x and 1x address range i n [0x 1x address range] dialog box, referring to bit range of the device used. www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 364 add set [station no.], [device type] , [m in . address] , [max. address] then click [ok] to finish adding as below: delete the selected items will be deleted. settings set [station no.], [device type] , [m in . address] , [max. address] then click [ok] to fini sh adding as below: example take d2 and d8 of scon as example, the settings depend on bit range of different plc types. set [station no.] and address first. for d2, set [station no.] to 20 , [device type] 0x , [max. address] 36 . for d8, set [station n o.] to 2 , [device type] 0x , [max. address] 51 . www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 365 note: if communicating with a rs - 485 2w plc, the [turn around delay] setting may need to be adjusted according to the reply speed of the device. please click [settings] in [device properties], and set the [turn around delay (ms)] parameter as shown: after co mpleting all settings above, the communication is enabled. www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 366 wiring d iagram: the following represents the view of hmi & plc. modbus rtu controller : rs232 e mt 3 000 series com1 rs232 9p d - sub fem a le com 3 rs232 9p d - sub fem ale rs232 9p d - sub female 2 rx 8 rx t x d 3 tx 7 tx r x d 5 gnd 5 gnd gnd rts circuit cts mt6000 /8000 series except mt6050i/mt8050i com1 rs232 9p d - sub fem ale com2 rs232 9p d - sub fem ale com3 rs232 9p d - su b m ale rs232 9p d - sub female 2 rx 6 rx 8 rx t x d 3 tx 4 tx 7 tx r x d 5 gnd 5 gnd 5 gnd gnd rts circuit cts mt6050i/mt8050i com1 rs232 9p d - sub fem ale rs232 9p d - sub female 9 rx t x d 6 tx r x d 5 gnd gnd rts circuit cts www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 367 the following represents the view of hmi & plc. modbus rtu controller : rs485 4w e mt 3 000 series com1 rs485 4 w 9p d - sub m ale rs 485 4w 9p d - sub male 1 rx - tx - 2 r x + tx+ 3 tx - rx - 4 tx+ rx+ 5 gnd gnd mt6000 /8000 series except mt6050i/mt8050i com1 rs485 4 w 9p d - sub m ale rs 485 4w 9p d - sub male 1 rx - tx - 2 r x + tx+ 3 tx - rx - 4 tx+ rx+ 5 gnd gnd mt6050i/mt8050i com1 rs485 4 w 9p d - sub fem ale rs 485 4w 9p d - sub female 1 rx - tx - 2 r x + tx+ 3 tx - rx - 4 tx+ rx+ 5 gnd gnd www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 368 the following represents the view of hmi & plc. modbus rtu controller : rs485 2w e mt 3 000 series com1 rs485 2 w 9p d - sub m ale com 3 rs485 2 w 9p d - sub m ale rs 485 2w 9p d - sub male 1 rx - 6 data - d - 2 rx+ 9 data+ d+ 5 gnd 5 gnd gnd mt6000 /8000 series except mt6050i/mt8050i com1 rs485 2 w 9p d - sub m ale com 3 rs485 2 w 9p d - sub m ale rs 485 2w 9p d - sub male 1 rx - 6 data - d - 2 rx+ 9 data+ d+ 5 gnd 5 gnd gnd mt6050i/mt8050i com1 rs485 2 w 9 p d - sub fem ale com 3 rs485 2 w 9p d - sub fem ale rs 485 2w 9p d - sub female 1 rx - 7 data - d - 2 rx+ 8 data+ d+ 5 gnd 5 gnd gnd driver version : version date description v1. 1 0 aug/2 5 /20 10 v1.20 mar/2/2012 a llow modifying the minimum address of 0 x 1x address range . www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 369 modbus rtu (adjustable) supported s eries : modbus rtu controller website : http://www.modbus.org hmi setting: parameters recommend ed options notes plc t ype modbus rtu (adjustable) plc i/f rs 485 rs 232/rs485 baud r at e 9600 9600 / 19200 /3840 0/57600/115200 data b its 8 7, 8 parity even even, odd, none stop b its 1 1 ,2 plc s t a . n o. 1 0 - 255 online s imulator yes extend a ddress m ode yes plc setting: communication m ode modbus rtu protocol device a ddress: bit/word device t ype format range memo b 0x ddddd 1 ~ 65535 output bit b 1x ddddd 1 ~ 65535 input bit (read only) b 3x_bit ddddddd 1 00 ~ 65535 15 input register bit (read only) b 4x_bit ddddddd 1 00 ~ 65535 15 output register bit b 0x _mu lti_coils ddddd 1 ~ 65535 write m ultiple c oils w 3x ddddd 1 ~ 65535 input register (read only) w 4x ddddd 1 ~ 65535 output register w 5x ddddd 1 ~ 65535 4x double word swap dw 5x (32 - bit) ddddd 1 ~ 65535 4x double word w 6x ddddd 1 ~ 65535 4x single w ord write www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 370 note: address type 5x is mapping to hold reg. the communication protocol of 5x is almost the same as 4x except that 5x swap s double words. if 4x contains the following information: address 1 2 3 4 5 6 ... data in word 0x1 0x2 0x3 0x4 0x 5 0x6 data 0x20001 0x40003 0x60005 for 5x, i t will be : address 1 2 3 4 5 6 ... data in word 0x2 0x1 0x4 0x3 0x6 0x5 data 0x10002 0x30004 0x50006 modbus rtu function code: 0x 0x01 read coil 0x05 write single coil 0x_multi_co ils 0x01 read coil 0x0f write multiple coil s 1x 0x02 read discrete input n/a for writing operation 3x 0x04 read input register n/a for writing operation 4x 0x03 read holding register 0x10 write multiple regis ter s 5x 0x03 read holding register 0x10 write multiple register s (note: reverse word order in double words format) 3xbit is equivalent to 3x 4xbit is equivalent to 4x 6x 0x03 read holding register 0x06 w rite single register (note: 6x is limited to device of one word only) www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 371 setting i nstructions : 1. go to [system parameter settings] click [new] to add a new device - modbus rtu (adjustable) as shown below: 2. after adding modbus rtu (adjustable) driver, [add address range limit] button will be enabled as below. users can set maximum read/write command size here. ? max.read - command size (words): pull down to select plc reading range. ? max.write - command size (words): pull down to select plc writing range. www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 372 note: modbus rtu (adjustable) usage users can decide the address range via setting value on parameter 1. for example, when users s et 5 to param eter 1, the address range will be 5 ~ 65535. www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 373 wiring d iagram: the following represents the view of hmi & plc. modbus rtu controller : rs232 e mt 3 000 series com1 rs232 9p d - sub fem ale com 3 rs232 9p d - sub fem ale rs232 9p d - sub female 2 rx 8 r x t x d 3 tx 7 tx r x d 5 gnd 5 gnd gnd rts circuit cts mt6000 /8000 series except mt6050i/mt8050i com1 rs232 9p d - sub fem ale com2 rs232 9p d - sub fem ale com3 rs232 9p d - sub m ale rs232 9p d - sub female 2 rx 6 rx 8 rx t x d 3 tx 4 tx 7 tx r x d 5 gnd 5 gnd 5 gnd gnd rts circuit cts mt6050i/mt8050i com1 rs232 9p d - sub fem ale rs232 9p d - sub female 9 rx t x d 6 tx r x d 5 gnd gnd rts circuit cts www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 374 the following represents the view of hmi & plc. mod bus rtu controller : rs485 4w e mt 3 000 series com1 rs485 4 w 9p d - sub m ale rs 485 4w 9p d - sub male 1 rx - tx - 2 r x + tx+ 3 tx - rx - 4 tx+ rx+ 5 gnd gnd mt6000 /8000 series except mt6050i/mt8050i com1 rs485 4 w 9p d - sub m ale rs 485 4w 9p d - sub male 1 rx - tx - 2 r x + tx+ 3 tx - rx - 4 tx+ rx+ 5 gnd gnd mt6050i/mt8050i com1 rs485 4 w 9p d - sub fem ale rs 485 4w 9p d - sub female 1 rx - tx - 2 r x + tx+ 3 tx - rx - 4 tx+ rx+ 5 gnd gnd www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 375 the follo wing represents the view of hmi & plc. modbus rtu controller : rs485 2w e mt 3 000 series com1 rs485 2 w 9p d - sub m ale com 3 rs485 2 w 9p d - sub m ale rs 485 2w 9p d - sub male 1 rx - 6 data - d - 2 rx+ 9 data+ d+ 5 gnd 5 gnd gnd mt6000 /8000 series excep t mt6050i/mt8050i com1 rs485 2 w 9p d - sub m ale com 3 rs485 2 w 9p d - sub m ale rs 485 2w 9p d - sub male 1 rx - 6 data - d - 2 rx+ 9 data+ d+ 5 gnd 5 gnd gnd mt6050i/mt8050i com1 rs485 2 w 9p d - sub fem ale com 3 rs485 2 w 9p d - sub fem ale rs 485 2w 9p d - su b female 1 rx - 7 data - d - 2 rx+ 8 data+ d+ 5 gnd 5 gnd gnd driver version : version date description v1. 4 0 jun/14/2011 www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 376 m odbus rtu (zero - based addressing) supported s eries : modbus rtu controller website : http://www.m odbus.org hmi setting: parameters recommend ed option s notes plc type modbus rtu (zero - based addressing) plc i/f rs 485 rs 232/rs485 baud rate 9600 9600 ~ 115200 data b its 8 7, 8 parity even even, odd, none stop b its 1 1 ,2 plc s t a . n o. 1 0 - 255 online s imulator yes broadcast command yes extend address mode yes plc setting: communication mode modbus rtu protocol device a ddress: bit/word device t ype format range memo b 0x ddddd 0 ~ 65535 output bit b 1x ddddd 0 ~ 65535 i nput bit (read only) b 3x_bit ddddddd 0 ~ 65535 15 input register bit (read only) b 4x_bit ddddddd 0 ~ 65535 15 output register bit b 0x _multi_coils ddddd 0 ~ 65535 write m ultiple c oils w 3x ddddd 0 ~ 65535 input register (read only) w 4x ddddd 0 ~ 6553 5 output register dw 5x ddddd 0 ~ 65535 4x double word swap w 6x ddddd 0 ~ 65535 4x single word write www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 377 note: address type 5x is mapping to hold reg. the communication protocol of 5x is almost the same as 4x except that 5x swaps double word s . if 4x contains the following information : address 1 2 3 4 5 6 ... data in word 0x1 0x2 0x3 0x4 0x5 0x6 data 0x20001 0x40003 0x60005 for 5x, it will be: address 1 2 3 4 5 6 ... data in word 0x2 0x1 0x4 0x3 0x6 0x5 data 0x10002 0x30004 0x50006 modbus rtu function code: 0x 0x01 read coil 0x05 write single coil 0x_multi_coils 0x01 read coil 0x0f write multiple coil s 1x 0x02 read discrete input n/a for write operation 3x 0x04 read input register n/a for write operation 4x 0x03 read holding register 0x10 write multiple register s 5x 0x03 read holding register 0x10 write multiple register s ( n ote: reverse word order in double word format) 3xbit is equivalent to 3x 4xbit is equiv alent to 4x 6x 0x03 read holding register 0x06 write single register ( n ote: 6x is limited to device of one word only) www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 378 wiring d iagram: the following represents the view of hmi & plc. modbus rtu controller : rs232 e mt 3 000 series com1 rs232 9p d - sub fem ale com 3 rs232 9p d - sub fem ale rs232 9p d - sub female 2 rx 8 rx t x d 3 tx 7 tx r x d 5 gnd 5 gnd gnd rts circuit cts mt6000 /8000 series except mt6050i/mt8050i com1 rs232 9p d - sub fem ale com2 rs232 9p d - sub fem ale com3 rs232 9p d - sub m ale rs232 9p d - sub female 2 rx 6 rx 8 rx t x d 3 tx 4 tx 7 tx r x d 5 gnd 5 gnd 5 gnd gnd rts circuit cts mt6050i/mt8050i com1 rs232 9p d - sub fem ale rs232 9p d - sub female 9 rx t x d 6 tx r x d 5 gnd gnd rts circui t cts www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 379 the following represents the view of hmi & plc. modbus rtu controller : rs485 4w e mt 3 000 series com1 rs485 4 w 9p d - sub m ale rs 485 4w 9p d - sub male 1 rx - tx - 2 r x + tx+ 3 tx - rx - 4 tx+ rx+ 5 gnd gnd mt6000 /800 0 series except mt6050i/mt8050i com1 rs485 4 w 9p d - sub m ale rs 485 4w 9p d - sub male 1 rx - tx - 2 r x + tx+ 3 tx - rx - 4 tx+ rx+ 5 gnd gnd mt6050i/mt8050i com1 rs485 4 w 9p d - sub fem ale rs 485 4w 9p d - sub female 1 rx - tx - 2 r x + tx+ 3 tx - rx - 4 tx+ rx+ 5 gnd gnd www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 380 the following represents the view of hmi & plc. modbus rtu controller : rs485 2w e mt 3 000 series com1 rs485 2 w 9p d - sub m ale com 3 rs485 2 w 9p d - sub m ale rs 485 2w 9p d - sub male 1 rx - 6 data - d - 2 rx+ 9 data+ d+ 5 gnd 5 gnd gnd mt6000 /8000 series except mt6050i/mt8050i com1 rs485 2 w 9p d - sub m ale com 3 rs485 2 w 9p d - sub m ale rs 485 2w 9p d - sub male 1 rx - 6 data - d - 2 rx+ 9 data+ d+ 5 gnd 5 gnd gnd mt6050i/mt8050i com1 rs 485 2 w 9p d - sub fem ale com 3 rs485 2 w 9p d - sub fem ale rs 485 2w 9p d - sub female 1 rx - 7 data - d - 2 rx+ 8 data+ d+ 5 gnd 5 gnd gnd driver version : version date description v1.30 aug/26/2009 www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 381 modbus server (com/ethernet) hmi setting: param eters recommend ed option s notes plc type modbus server (com/ethernet) plc i/f rs232 rs232, rs485 baud rate 9600 9600~115200 ethernet ethernet supports udp or tcp/ip protocol data b its 8 8 parity even even, odd, none stop b its 1 1 plc s t a . n o. 1 1 - 31 hmi modbus station no. port n o. 502 online simulator yes extend address mode no broadcast command no plc setting: communication mode modbus rtu protocol modbus server udp protocol setting: modbus server (ethernet) supports udp communicati on protocol. to use udp mode, go to [system parameter settings] in editing software, in [device list] click [new], for [plc type] select modbus server, [plc i/f] set to [ethernet], and select [use udp (user datagram protocol)] to finish setting. www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 382 modbu s server port no. can be changed by clicking [settings]. modbus server port no. can not be set identically to hmi port no. when doing so, the warning message below will be shown requesting users to change setting. n ote: a maximum of 64 clients can be c onnected simultaneously. modbus server port no. cant be identical to hmi port no. www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 383 modbus server tcp/ip protocol setting: modbus server (ethernet) support s tcp/ip communication protocol . go to [system parameter settings ] in editing software, in [device li st] click [new ] , for [plc type ] select modbus server , [plc i/f ] set to [ethernet ] to finish setting. for modbus server tcp/ip, hmi port no. is the same as modbus server port no. to change prot no. go to [system parameter settings] / [model], the defaul t port no. is 8000 , and it is allowed to change modbus server port no. here . www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 384 device a ddress: bit/word device t ype format range memo b lb dddd 0 ~ 9998 mapping to 0x/1x 1 ~ 9999 w lw dddd 0 ~ 9998 mapping to 3x/4x 1 ~ 9999 w rw ddddd 0 ~ 55536 mappin g to 3x/4x 10000 ~ 65536 lb0 = 0x0001, lb1 = 0x0002, lw0 = 3x0001, lw1 = 3x0002 modbus rtu s erver doesnt support function c ode 06( preset single register), please use function code 16(0x10, preset multiple register s ). modbus server function code : 0x 0x01 read coil 0x05 write single coil 0x_multi_coils 0x01 read coil 0x0f write multiple coil s 1x 0x02 read discrete input n/a for write operation 3x 0x04 read input register n/a for write operation 4x 0x03 read holding register 0x10 write multiple register s wiring d iagram: the following represents the view of hmi & plc. modbus server : rs232 e mt 3 000 series com1 rs232 9p d - sub fem ale com 3 rs232 9p d - sub fem ale rs232 9p d - sub female 2 rx 8 rx t x d 3 tx 7 tx r x d 5 gnd 5 gnd gnd rts circuit cts www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 385 mt6000 /8000 series except mt6050i/mt8050i com1 rs232 9p d - sub fem ale com2 rs232 9p d - sub fem ale com3 rs232 9p d - sub m ale rs232 9p d - sub female 2 rx 6 rx 8 rx t x d 3 tx 4 tx 7 tx r x d 5 gnd 5 gnd 5 gnd gnd rts circuit cts mt6050i/mt8050i com1 rs232 9p d - sub fem ale rs232 9p d - sub female 9 rx t x d 6 tx r x d 5 gnd gnd rts circuit cts the following represents the view of hmi & pl c. modbus server : rs485 4w e mt 3 000 series com1 rs485 4 w 9p d - sub m ale rs 485 4w 9p d - sub male 1 rx - tx - 2 r x + tx+ 3 tx - rx - 4 tx+ rx+ 5 gnd gnd www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 386 mt6000 /8000 series except mt6050i/mt8050i com1 rs485 4 w 9p d - sub m ale rs 485 4w 9p d - sub male 1 rx - tx - 2 r x + tx+ 3 tx - rx - 4 tx+ rx+ 5 gnd gnd mt6050i/mt8050i com1 rs485 4 w 9p d - sub fem ale rs 485 4w 9p d - sub female 1 rx - tx - 2 r x + tx+ 3 tx - rx - 4 tx+ rx+ 5 gnd gnd the followi ng represents the view of hmi & plc. modbus server : rs485 2w e mt 3 000 series com1 rs485 2 w 9p d - sub m ale com 3 rs485 2 w 9p d - sub m ale rs 485 2w 9p d - sub male 1 rx - 6 data - d - 2 rx+ 9 data+ d+ 5 gnd 5 gnd gnd www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 387 mt6000 /8000 series except mt6050 i/mt8050i com1 rs485 2 w 9p d - sub m ale com 3 rs485 2 w 9p d - sub m ale rs 485 2w 9p d - sub male 1 rx - 6 data - d - 2 rx+ 9 data+ d+ 5 gnd 5 gnd gnd mt6050i/mt8050i com1 rs485 2 w 9p d - sub fem ale com 3 rs485 2 w 9p d - sub fem ale rs 485 2w 9p d - sub fem ale 1 rx - 7 data - d - 2 rx+ 8 data+ d+ 5 gnd 5 gnd gnd modbus server : ethernet direct connect (crossover cable): hmi rj45 male wire color wire color plc rj45 male 1 tx+ white/orange white/green 3 rx+ 2 tx - orange green 6 rx - 3 rx+ white/gre en white/orange 1 tx+ 4 bd4+ blue blue 4 bd4+ 5 bd4 - white/blue white/blue 5 bd4 - 6 rx - green orange 2 tx - 7 bd3+ white/brown white/brown 7 bd3+ 8 bd3 - brown brown 8 bd3 - www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 3 88 through a hub: hmi rj45 male wire color wire color plc rj45 male 1 tx+ white/orange white/orange 1 tx+ 2 tx - orange orange 2 tx - 3 rx+ white/green white/green 3 rx+ 4 bd4+ blue blue 4 bd4+ 5 bd4 - white/blue white/blue 5 bd4 - 6 rx - green green 6 rx - 7 bd3+ white/brown white/brown 7 bd3+ 8 bd3 - brown brown 8 bd3 - n ote: setting more than one modbus server in hmi device list is of no effect. driver version : version date description v1.00 dec/30/2008 driver released www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 389 modbus tcp/ip supported s eries: modbus rtu tcp/ip device. website: http://www.modbus.org hmi setting: parameters recommend ed option s notes plc type modbus tcp/ip plc i/f ethernet p ort n o. 502 plc s t a . n o. 1 0~255 device a ddress: bit/word device t ype format range memo b 0x ddddd 1 ~ 65535 input bit b 1x ddddd 1 ~ 65535 output bit b 3x_bit ddddddd 1 00 ~ 65535 15 input register bit(read only) b 4x_bit ddddddd 1 00 ~ 65535 15 output register bit b 6x_bit ddddddd 1 00 ~ 65535 15 output register bit b 0x_multi_coils ddddd 1 ~ 65535 write m ultiple c oils w 3x ddddd 1 ~ 65535 input register w 4x ddddd 1 ~ 65535 output register dw 5x ddddd 1 ~ 65535 4x double word swap w 6x ddddd 1 ~ 65535 4x single word write w 4x string central e urope rev ddddd 1 ~ 65535 www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 390 wiring d iagram: direct connect (crossover cab le): hmi rj45 male wire color wire color plc rj45 male 1 tx+ white/orange white/green 3 rx+ 2 tx - orange green 6 rx - 3 rx+ white/green white/orange 1 tx+ 4 bd4+ blue blue 4 bd4+ 5 bd4 - white/blue white/blue 5 bd4 - 6 rx - green orange 2 tx - 7 bd3+ whi te/brown white/brown 7 bd3+ 8 bd3 - brown brown 8 bd3 - through a hub: hmi rj45 male wire color wire color plc rj45 male 1 tx+ white/orange white/orange 1 tx+ 2 tx - orange orange 2 tx - 3 rx+ white/green white/green 3 rx+ 4 bd4+ blue blue 4 bd4+ 5 bd4 - white/blue white/blue 5 bd4 - 6 rx - green green 6 rx - 7 bd3+ white/brown white/brown 7 bd3+ 8 bd3 - brown brown 8 bd3 - driver version : version date description v1.50 aug/26/2009 www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 391 modbus tcp/ip (0x/1x range adjustable) supported s eries : modbus rtu tcp/ip device. website : http://www.modbus.org hmi setting: parameters recommend ed option s notes plc type modbus tcp/ip (0x/1x range adjustable) plc i/f ethernet p ort n o. 502 plc s t a . n o. 1 0~255 online s imulator yes extend a ddress m ode yes device a ddress: bit/word device t ype format range memo b 0x ddddd 1 ~ 65535 output bit b 1x ddddd 1 ~ 65535 input bit (read only) b 3x_bit ddddddd 1 00 ~ 65535 15 input register bit (read only) b 4x_bit ddddddd 1 00 ~ 65535 15 output register bit b 6 x_bit ddddddd 1 00 ~ 65535 15 output register bit b 0x _multi_coils ddddd 1 ~ 65535 write m ultiple c oils w 3x ddddd 1 ~ 65535 input register (read only) w 4x ddddd 1 ~ 65535 output register dw 5x ddddd 1 ~ 655 35 4x double word swap w 6x ddddd 1 ~ 65535 4x single word write w 4x string central e urope rev ddddd 1 ~ 65535 www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 392 note: address type 5x is mapping to hold reg. the communication protocol of 5x is almost the same as 4x except that 5x swap s doubl e words. if 4x contains the following information: address 1 2 3 4 5 6 ... data in word 0x1 0x2 0x3 0x4 0x5 0x6 data 0x20001 0x40003 0x60005 for 5x, i t will be : address 1 2 3 4 5 6 ... data in word 0x2 0x1 0x4 0x3 0x6 0x5 data 0x10002 0x30004 0x50 006 modbus rtu function code: 0x 0x01 read coil 0x05 write single coil 0x_multi_coils 0x01 read coil 0x0f write multiple coil s 1x 0x02 read discrete input n/a for writing operation 3x 0x04 read input regi ster n/a for writing operation 4x 0x03 read holding register 0x10 write multiple register s 5x 0x03 read holding register 0x10 write multiple register s (note: reverse word order in double words format) 3xbit is equivalent to 3x 4xbit is equivalent to 4x 6x 0x03 read holding register 0x06 w rite single register (note: 6x is limited to device of one word only) www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 393 setting i nstructions : 1. go to [system parameter settings] click [new] to add a new device - modbus tcp/ip (0x/1x range adjustable) as shown below: 2. click [add address range limit] button, users can define 0x and 1x address range i n [0x 1x address range] dialog box, referring to bit range of the device used. www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 394 add set [station no.], [device type], [max. address] then click [ok] to finish adding as below: delete the selected items will be deleted. settings set [station no.], [device type], [max. address] then click [ok] to finish adding as below: www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 395 example take 0x and 1x as example, the settings depend on bit range of different plc types. for 0x , [device type] 0x , [m in . address] 5 , [max. address] 20 . for 1x , [device type] 0x , [m in . address] 1 , [max. address] 10 . after co mpleting all settings above, the communication is enabled. www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 396 wiring d iagram: direct connect (crossover cable): hmi rj45 male wire color wire color plc rj45 male 1 tx+ white/orange white/green 3 rx+ 2 tx - orange green 6 rx - 3 rx+ white/green white/orange 1 tx+ 4 bd4+ blue blue 4 bd4+ 5 bd4 - white/blue white/blue 5 bd4 - 6 rx - green orange 2 tx - 7 bd3+ white/brown white/brown 7 bd3+ 8 bd3 - brown brown 8 bd3 - through a hub: hmi rj45 male wire color wire color plc rj45 male 1 tx+ white/orange white/orange 1 tx+ 2 tx - orange ora nge 2 tx - 3 rx+ white/green white/green 3 rx+ 4 bd4+ blue blue 4 bd4+ 5 bd4 - white/blue white/blue 5 bd4 - 6 rx - green green 6 rx - 7 bd3+ white/brown white/brown 7 bd3+ 8 bd3 - brown brown 8 bd3 - driver version : version date description v1. 0 0 n ov/2/2011 driver released . v1.10 mar/14/2012 a llow modifying the minimum address of 0x 1x address range . www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 397 m odbus tcp/ip (zero - based addressing) suppo rted s eries : modbus rtu tcp/ip device. website: http://www.modbus.org hmi setting: parameters recommend ed option s notes plc type modbus tcp/ip (zero - based addressing) plc i /f ethernet p ort n o. 502 plc s t a . n o. 1 0~255 device a ddress: bit/word device t ype format range memo b 0x ddddd 0 ~ 65535 input bit b 1x ddddd 0 ~ 65535 output bit b 3x_ b it ddddddd 0 ~ 65535 15 input register bit (read only) b 4x_ b it ddddddd 0 ~ 65535 15 output register bit b 6x_ b it ddddddd 0 ~ 65535 15 output register bit b 0x_multi_coils ddddd 0 ~ 65535 write m ultiple c oils w 3x ddddd 0 ~ 65535 input register w 4x ddddd 0 ~ 65535 output register dw 5x ddddd 0 ~ 655 35 4x double word swap w 6x ddddd 0 ~ 65535 4x single word write www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 398 wiring d iagram: direct connect (crossover cable): hmi rj45 male wire color wire color plc rj45 male 1 tx+ white/orange white/green 3 rx+ 2 tx - orange green 6 rx - 3 rx+ white/green whit e/orange 1 tx+ 4 bd4+ blue blue 4 bd4+ 5 bd4 - white/blue white/blue 5 bd4 - 6 rx - green orange 2 tx - 7 bd3+ white/brown white/brown 7 bd3+ 8 bd3 - brown brown 8 bd3 - through a hub: hmi rj45 male wire color wire color plc rj45 male 1 tx+ white/or ange white/orange 1 tx+ 2 tx - orange orange 2 tx - 3 rx+ white/green white/green 3 rx+ 4 bd4+ blue blue 4 bd4+ 5 bd4 - white/blue white/blue 5 bd4 - 6 rx - green green 6 rx - 7 bd3+ white/brown white/brown 7 bd3+ 8 bd3 - brown brown 8 bd3 - driver v ersion : version date description v1.40 aug/27/2009 www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 399 m odbus tcp/ip 32 bi t supported s eries: modbus rtu tcp/ip device. website: http://www.modbus.org hmi setting: parameters recommend ed option s notes plc type modb us tcp/ip 32bit plc i/f ethernet p ort n o. 502 plc s t a . n o. 1 0~255 device a ddress: bit/word device t ype format range memo b 0x ddddd 1 ~ 65535 input bit b 1x ddddd 1 ~ 65535 output bit b 3x_ b it ddddddd 100 ~ 65535 15 input register bit (read o nly) b 4x_ b it ddddddd 100 ~ 65535 15 output register bit b 6x_ b it ddddddd 100 ~ 65535 15 output register bit b 0x_multi_coils ddddd 1 ~ 65535 write m ultiple c oils w 3x ddddd 1 ~ 65535 input register w 4x ddddd 1 ~ 65535 output register dw 5x ddddd 1 ~ 65535 4x double word swap w 6x ddddd 1 ~ 65535 4x single word write w 4x_32bit * ddddd 1 ~ 65535 4x_32bit will only read / write 2 words for each package , for continuous addresses, it will be divided into several packages. www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 400 wiring d iagram: direct conn ect (crossover cable): hmi rj45 male wire color wire color plc rj45 male 1 tx+ white/orange white/green 3 rx+ 2 tx - orange green 6 rx - 3 rx+ white/green white/orange 1 tx+ 4 bd4+ blue blue 4 bd4+ 5 bd4 - white/blue white/blue 5 bd4 - 6 rx - green orange 2 tx - 7 bd3+ white/brown white/brown 7 bd3+ 8 bd3 - brown brown 8 bd3 - through a hub: hmi rj45 male wire color wire color plc rj45 male 1 tx+ white/orange white/orange 1 tx+ 2 tx - orange orange 2 tx - 3 rx+ white/green white/green 3 rx+ 4 bd4+ blue blue 4 bd4+ 5 bd4 - white/blue white/blue 5 bd4 - 6 rx - green green 6 rx - 7 bd3+ white/brown white/brown 7 bd3+ 8 bd3 - brown brown 8 bd3 - driver version : version date description v1. 1 0 aug/27/2009 driver released . www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 401 mo eller xc - cpu101 suppo rted s eries: moeller xc100/200 series website: http://www.moeller.net hmi setting: parameters recommend ed option s notes plc type moeller xc - cpu101 plc i /f rs232 baud rate 38400 4800 ~ 57600 data b its 8 p arity none stop b its 1 plc s t a . n o. 1 device a ddress: bit/word device t ype format range note b qx ddo 0 ~ 15 7 b ix ddo 0 ~ 15 7 w mw dddd 0 ~ 4095 w qw dd 0 ~ 15 w iw dd 0 ~ 15 wiring d iagram: the following represents the view of hmi & plc. e mt 3 000 series com1 rs232 9p d - sub fem ale com 3 rs232 9p d - sub fem ale rs232 8p rj45 male 2 rx 8 rx 5 t d 3 tx 7 tx 8 r d 5 gnd 5 gnd 4 gnd www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 402 mt6000 /8000 series except mt6050i/mt8050i com1 rs232 9p d - sub fem ale com2 rs232 9p d - sub fem ale co m3 rs232 9p d - sub m ale rs232 8p rj45 male 2 rx 6 rx 8 rx 5 t d 3 tx 4 tx 7 tx 8 r d 5 gnd 5 gnd 5 gnd 4 gnd mt6050i/mt8050i com1 rs232 9p d - sub fem ale rs232 8p rj45 male 9 rx 5 t d 6 tx 8 r d 5 gnd 4 gnd driver version : version date description 1.00 apr/01/2010 driver released . www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 403 ohjx website: http://www.ohjx.com/ hmi setting: parameters recommend ed option s notes plc type ohjx plc i/f rs - 232 baud rate 9600 9600,19200 data bits 8 parity odd stop bits 1 plc s t a . n o. 1 device address: bit/word device type format range memo b r100 dh 0 ~ 1f b r101 dh 0 ~ 1f b r102 dh 0 ~ 1f b r103 dh 0 ~ 1f b r104 dh 0 ~ 1f b r105 dh 0 ~ 1f b r106 dh 0 ~ 1f b r107 dh 0 ~ 1f b r108 dh 0 ~ 1f b r109 dh 0 ~ 1f b r110 dh 0 ~ 1f b r210 dh 0 ~ 1f b r310 dh 0 ~ 1f w sv dddd 0 ~ 9999 w ev ddddd 0 ~ 65535 w dt ddddd 0 ~ 9999 w ld dddd 0 ~ 8447 w wx dddd 0 ~ 9999 www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 404 bit/word device type format range memo w wy dddd 0 ~ 9999 w wr dddd 0 ~ 9999 w wl ddd d 0 ~ 9999 w fl ddddd 0 ~ 99999 wiring diagram: the following represents the view of hmi & plc. e mt 3 000 series com1 rs232 9p d - sub fem ale com 3 rs232 9p d - sub fem ale 4 p m ini - din male 2 rx 8 rx 3 t x 3 tx 7 tx 2 r x 5 gnd 5 gnd 1 gnd circuit 4 gn d mt6000 /8000 series except mt6050i/mt8050i com1 rs232 9p d - sub fem ale com2 rs232 9p d - sub fem ale com3 rs232 9p d - sub m ale 4 p m ini - din male 2 rx 6 rx 8 rx 3 t x 3 tx 4 tx 7 tx 2 r x 5 gnd 5 gnd 5 gnd 1 gnd circuit 4 gnd www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 405 mt6050i/mt 8050i com1 rs232 9p d - sub fem ale 4 p m ini - din male 9 rx 3 t x 6 tx 2 r x 5 gnd 1 gnd circuit 4 gnd driver version : version date description v 1.00 nov/22/2011 driver released. www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 406 omron c/cqm1 s eries supported s eries: omron c, cpm, cpl, c qm series (host link protocol) website: http://oeiweb.omron.com/oei/products - plc.htm hmi setting: parameters recommend ed option s notes plc type omron c/cqm1 series plc i/f rs232 rs232, rs422 , rs485 baud rate 9600 9600, 19200 data b its 7 7 or 8 parity even even, odd, none stop b its 2 1 or 2 plc s t a . n o. 0 0 - 31 host link station no. online s imulator yes broadcast command yes extend address mode yes plc setting: communication mod e host link p rotocol device a ddress: bit/word device t ype format range memo b ir dddddd 0 ~ 409515 i/o and i nternal relay b hr dddddd 0 ~ 409515 hold relay b lr dddddd 0 ~ 409515 link relay b ir (force s et/reset) dddddd 0 ~ 409515 b hr (force set/re set) dddddd 0 ~ 409515 b lr (force s et/reset) dddddd 0 ~ 409515 b ar dddddd 0 ~ 409515 auxiliary relay w ar_w dddd 0 ~ 4095 w ir_w dddd 0 ~ 4095 w hr_w dddd 0 ~ 4095 w lr_w dddd 0 ~ 4095 w tc ddd 0 ~ 255 w dm dddd 0 ~ 9999 data r egister www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 407 w iring d iagram: the following represents the view of hmi & plc. cpu port (cpm2a,cqm1/1h,c200h/hs/alpha series) communication module: cpm1 - cif01 adapter (for cpm1/cpm1a/cpm2a series, cqm1/cqm1h series) cpm1h - scb41 communication module (for cqm1h - cpu51/61) e m t 3 000 series com1 rs232 9p d - sub fem ale com 3 rs232 9p d - sub fem ale rs232 9p d - sub male 2 rx 8 rx 2 s d 3 tx 7 tx 3 r d 5 gnd 5 gnd 9 gnd 4 rs circuit 5 cs mt6000 /8000 series except mt6050i/mt8050i com1 rs232 9p d - sub fem ale com2 rs23 2 9p d - sub fem ale com3 rs232 9p d - sub m ale rs232 9p d - sub male 2 rx 6 rx 8 rx 2 s d 3 tx 4 tx 7 tx 3 r d 5 gnd 5 gnd 5 gnd 9 gnd 4 rs circuit 5 cs www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 408 mt6050i/mt8050i com1 rs232 9p d - sub fem ale rs232 9p d - sub male 9 rx 2 s d 6 tx 3 r d 5 gnd 9 gnd 4 rs circuit 5 cs the following represents the view of hmi & plc. c200h - lk201,3g2a6 - lk201 communication module c200hw - com02/03/04/05/06 communication module e mt 3 000 series com1 rs232 9p d - sub fem ale com 3 rs232 9p d - sub fem ale rs232 9p d - sub male 2 rx 8 rx 2 s d 3 tx 7 tx 3 r d 5 gnd 5 gnd 7 gnd 4 rs circuit 5 cs mt6000 /8000 series except mt6050i/mt8050i com1 rs232 9p d - sub fem ale com2 rs232 9p d - sub fem ale com3 rs232 9p d - sub m ale rs232 9p d - sub male 2 rx 6 rx 8 rx 2 s d 3 tx 4 tx 7 tx 3 r d 5 gnd 5 gnd 5 gnd 7 gnd 4 rs circuit 5 cs www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 409 mt6050i/mt8050i com1 rs232 9p d - sub fem ale rs232 9p d - sub male 9 rx 2 s d 6 tx 3 r d 5 gnd 7 gnd 4 rs circuit 5 cs driver version : versi on date description v1. 8 0 apr/14/2010 www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 410 omron cj/cs /cp supported s eries: omron cp1e, cp1l, cp1h, cj1m, cj2m, cj1h, cj m 1g, cs1h and cs1g. (host link protocol fins command), this dri ver supports extend addressing m ode. website: http://oeiweb.omron.com/oei/products - plc.htm hmi setting: parameters recommend ed option s notes plc type omron cj/cs/cp plc i/f rs232 rs232, rs422, rs485 baud rate 9600 9600 ~115200 data b its 7 7 or 8 parity even e ven, odd, none stop b its 2 1 or 2 plc s t a . n o. 0 0 - 31 host link station no. online s imulator yes extend address mode yes broadcast command no plc setting: communication mode host link p rotocol device a ddress: bit/word device t ype format range memo b cio_ b it ddddddd 0 ~ 3276715 channel i/o (cio) b w_ b it ddddddd 0 ~ 3276715 work area (wr) b h_ b it ddddddd 0 ~ 3276715 holding area (hr) b d_ b it ddddddd 0 ~ 3276715 data memory (dm) b a_ b it ddddddd 0 ~ 3276715 auxiliary relay (ar) b t_ b it dddddd d 0 ~ 3276715 timer (tim) b c_ b it ddddddd 0 ~ 3276715 counter (cnt) b c_flag dddd 0 ~ 4095 b t _flag dddd 0 ~ 4095 b lr_bit ddddd 0 ~ 19915 www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 411 bit/word device t ype format range memo w t ddddd 0 ~ 32767 timer (tim) w h ddddd 0 ~ 32767 holding area (hr) w d ddddd 0 ~ 32767 data memory (dm) w a ddddd 0 ~ 32767 auxiliary relay (ar) w w ddddd 0 ~ 32767 work area (wr) w c ddddd 0 ~ 32767 counter (cnt) w cio ddddd 0 ~ 32767 channel i/o (cio) w em0 ~ emc ddddd 0 ~ 32767 extend memory w lr ddd 0 ~ 199 wiring d iagram: the following represen ts the view of hmi & plc. 9p d - sub to 9p d - sub: e mt 3 000 series com1 rs232 9p d - sub fem ale com 3 rs232 9p d - sub fem ale rs232 9p d - sub male 2 rx 8 rx 2 s d 3 tx 7 tx 3 r d 5 gnd 5 gnd 9 gnd 4 rs circuit 5 cs mt6000 /8000 series except mt 6050i/mt8050i com1 rs232 9p d - sub fem ale com2 rs232 9p d - sub fem ale com3 rs232 9p d - sub m ale rs232 9p d - sub male 2 rx 6 rx 8 rx 2 s d 3 tx 4 tx 7 tx 3 r d 5 gnd 5 gnd 5 gnd 9 gnd 4 rs circuit 5 cs www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 412 mt6050i/mt8050i com1 rs232 9p d - sub fem al e rs232 9p d - sub male 9 rx 2 s d 6 tx 3 r d 5 gnd 9 gnd 4 rs circuit 5 cs the following represents the view of hmi & plc. cp1h/cp1l cp1w - cif11 rs4 85 4w : 9p d - sub to termainals : e mt 3 000 series com1 rs485 4 w 9p d - sub m ale cp1w - cif11 rs485 4w terminal 1 rx - sda 2 r x + sdb 3 tx - rda 4 tx+ rdb 5 gnd fg mt6000 /8000 series except mt6050i/mt8050i com1 rs485 4 w 9p d - sub m ale cp1w - cif11 rs485 4w terminal 1 rx - sda 2 r x + sdb 3 tx - rda 4 tx+ rdb 5 gnd fg www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 413 mt6050i/mt8050i com1 rs485 4 w 9p d - sub fem ale cp1w - cif11 rs485 4w terminal 1 rx - sda 2 r x + sdb 3 tx - rda 4 tx+ rdb 5 gnd fg cp1w - cif11: sw1 on, others off. driver version : version date description v1. 9 0 feb / 01 /201 1 adde d registers: lr, lr_bit www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 414 omron cj1/cs1 ( ethernet ) supported s eries: omron cj series, cs series, cp series +ethernet module . (ethernet fins) website: http://oeiweb.omron.com/oei/products - plc.h tm *on initialization, switch from run mode to monitor mode. hmi setting: parameters recommend ed option s notes plc type omron cj1/cs1 (ethernet) plc i/f ethernet port n o. 9600 plc s t a . n o. 0 plc setting: communication mode fins ethernet proto col device a ddress: bit/word device t ype format range memo b cio_ b it ddddddd 0 ~ 3276715 channel i/o (cio) b w_ b it ddddddd 0 ~ 3276715 work area (wr) b h_ b it ddddddd 0 ~ 3276715 holding area (hr) b a_ b it ddddddd 0 ~ 3276715 auxiliary relay (ar) (read only) b d_ b it ddddddd 0 ~ 3276715 data memory (dm) b t_ b it ddddddd 0 ~ 3276715 timer (tim) b c_ b it ddddddd 0 ~ 3276715 counter (cnt) b c_flag dddd 0 ~ 4095 b t_flag d ddd 0 ~ 4095 w cio ddddd 0 ~ 32767 channel i/o (cio) w w ddddd 0 ~ 32767 work are a (wr) w h ddddd 0 ~ 32767 holding area (hr) w a ddddd 0 ~ 32767 auxiliary relay (ar) (read only) w c ddddd 0 ~ 32767 counter (cnt) w t ddddd 0 ~ 32767 timer (tim) w d ddddd 0 ~ 32767 data memory (dm) w em0 ~ emc ddddd 0 ~ 32767 extend memory www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 415 wiring d iagram: direct connect (crossover cable): hmi rj45 male wire color wire color plc rj45 male 1 tx+ white/orange white/green 3 rx+ 2 tx - orange green 6 rx - 3 rx+ white/green white/orange 1 tx+ 4 bd4+ blue blue 4 bd4+ 5 bd4 - white/blue white/blue 5 bd4 - 6 rx - green orange 2 tx - 7 bd3+ white/brown white/brown 7 bd3+ 8 bd3 - brown brown 8 bd3 - through a hub: hmi rj45 male wire color wire color plc rj45 male 1 tx+ white/orange white/orange 1 tx+ 2 tx - orange orange 2 tx - 3 rx+ white/green white /green 3 rx+ 4 bd4+ blue blue 4 bd4+ 5 bd4 - white/blue white/blue 5 bd4 - 6 rx - green green 6 rx - 7 bd3+ white/brown white/brown 7 bd3+ 8 bd3 - brown brown 8 bd3 - driver version : version date description v1. 50 jun/30/2010 www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 416 omron e5cn/e5ez/e5z n supported s eries: omron e5 c n series t emperature controller with communication option s . e5en/cn/gn /ez/ z n series . website: http://oeiweb.omron.com hmi setting: parameters recommend ed option s notes plc type omron e5cn plc i/f rs 485 2w baud rate 9600 9600 / 19200 /38400/ 57600/115200 data b its 7 7, 8 parity even even, odd, none stop b its 2 1 ,2 plc s t a . n o. 0 0 - 99 online s imulator yes broadcast command yes extend address mode yes device a ddress: bit/w ord device t ype format range memo b status _ch1 dd 0 ~ 31 page40 b status _ch2 dd 0 ~ 31 dw c0 hhhh 0 ~ 270f read only (hex) page34 dw c1 hhhh 0 ~ 270f read/write (hex) page35 dw c 2 hhhh 0 ~ 270f read/write (hex) page35 dw c3 hhhh 0 ~ 270f read/write (hex) page36 w code 00 _00 h 0 communications writing off (disabled) w code 00 _0 1 h 0 communications writing on( e nabled) w code 0 1 _00 h 0 run w code 0 1 _0 1 h 0 stop w code 0 2 _00 h 0 multi - sp set point 0 w code 0 2 _0 1 h 0 multi - sp set point 1 w code 0 2 _0 2 h 0 multi - sp set point 2 www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 417 bit/w ord device t ype format range memo w code 0 2 _0 3 h 0 multi - sp set point 3 w code 0 3 _00 h 0 at cancel w code 0 3 _0 1 h 0 at execute w code 0 4 _00 h 0 write mode (backup) w code 0 4 _0 1 h 0 write mode (ram) w code 0 5 _00 h 0 save ram data w code 0 6 _0 0 h 0 software reset w code 0 7 _00 h 0 move to setup area 1 w code 0 8 _0 0 h 0 move to protect level w code 0 1 _ 1 0 h 0 w code 0 1 _ 11 h 0 w code 0 1 _ f0 h 0 w code 0 1 _ f1 h 0 w code 0 2 _ 10 h 0 w code 0 2 _ 11 h 0 w code 0 2 _ f 0 h 0 w code 0 2 _ f1 h 0 w code 0 3 _ 1 0 h 0 w code 0 3 _ 11 h 0 w code 0 3 _ f 0 h 0 w code 0 3 _ f1 h 0 w code 0 9 _00 h 0 w code 0 9 _0 1 h 0 w code 0 9 _ 1 0 h 0 w code 0 9 _ 11 h 0 w code 0 9 _ f 0 h 0 w code 0 9 _ f1 h 0 w code 0 a _ 00 h 0 w code 0 b _ 00 h 0 w code 0 c _ 00 h 0 w code 0 c _ 01 h 0 w code 0 c _ 02 h 0 w code 0 c _ 0f h 0 w code 0 c _ 1 0 h 0 w code 0 c _ 1 1 h 0 w code 0 c _ 12 h 0 w code 0 c _ 1f h 0 w code 0 c _ f0 h 0 w code 0 c _ f1 h 0 w code 0 c _ f2 h 0 www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 418 bit/w ord device t ype format range memo w code 0 c _ ff h 0 wiring d iagram: the following represents the view of hmi & plc. e mt 3 000 series com1 rs485 2 w 9p d - sub m ale com 3 rs485 2 w 9p d - sub m ale omron e5cn terminal 1 rx - 6 data - 12 b 2 rx+ 9 data+ 11 a 5 gnd 5 gnd gnd mt6000 /8000 series except mt6050i/mt8050i com1 rs485 2 w 9p d - sub m ale com 3 rs485 2 w 9p d - sub m ale omron e5cn terminal 1 rx - 6 data - 12 b 2 rx+ 9 dat a+ 11 a 5 gnd 5 gnd gnd mt6050i/mt8050i com1 rs485 2 w 9p d - sub fem ale com 3 rs485 2 w 9p d - sub fem ale omron e5cn terminal 1 rx - 7 data - 12 b 2 rx+ 8 data+ 11 a 5 gnd 5 gnd gnd www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 419 note : for communication w ith omron e5ez, please set communication setting s to 9600, e, 7, 2, station no. 1 . driver version : version date description v1.21 dec/21/2010 www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 420 omron fins (ethernet) supported s eries: non omron plc . (ethernet fins) hmi setting: parameters recommend ed option s notes plc type omron fins (ethernet) plc i/f ethernet port n o. 9600 plc s t a . n o. 0 plc setting: communication mode fins ethernet protocol device a ddress: bit/word device t ype format range memo b cio_ b it ddddddd 0 ~ 3276715 channel i/o (cio) b w_ b it ddddd dd 0 ~ 3276715 work area (wr) b h_ b it ddddddd 0 ~ 3276715 holding area (hr) b a_ b it ddddddd 0 ~ 3276715 auxiliary relay (ar) (read only) b d_ b it ddddddd 0 ~ 3276715 data memory (dm) b t_ b it ddddddd 0 ~ 3276715 timer (tim) b c_ b it ddddddd 0 ~ 3276715 c ounter (cnt) b c_flag dddd 0 ~ 4095 b t_flag dddd 0 ~ 4095 w cio ddddd 0 ~ 32767 channel i/o (cio) w w ddddd 0 ~ 32767 work area (wr) w h ddddd 0 ~ 32767 holding area (hr) w a ddddd 0 ~ 32767 auxiliary relay (ar) (read only) w c ddddd 0 ~ 32767 co unter (cnt) w t ddddd 0 ~ 32767 timer (tim) w d ddddd 0 ~ 32767 data memory (dm) w em0 ~ emc ddddd 0 ~ 32767 extend memory www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 421 wiring d iagram: direct connect (crossover cable): hmi rj45 male wire color wire color plc rj45 male 1 tx+ white/orange white/gre en 3 rx+ 2 tx - orange green 6 rx - 3 rx+ white/green white/orange 1 tx+ 4 bd4+ blue blue 4 bd4+ 5 bd4 - white/blue white/blue 5 bd4 - 6 rx - green orange 2 tx - 7 bd3+ white/brown white/brown 7 bd3+ 8 bd3 - brown brown 8 bd3 - through a hub: hmi rj4 5 male wire color wire color plc rj45 male 1 tx+ white/orange white/orange 1 tx+ 2 tx - orange orange 2 tx - 3 rx+ white/green white/green 3 rx+ 4 bd4+ blue blue 4 bd4+ 5 bd4 - white/blue white/blue 5 bd4 - 6 rx - green green 6 rx - 7 bd3+ white/brown whi te/brown 7 bd3+ 8 bd3 - brown brown 8 bd3 - driver version : version date description v1. 0 0 may/26/2011 driver released. www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 422 omron host link supported s eries: omron c, cpm, cpl, cqm series (host link protocol) website: http://oeiweb.omron.com/oei/products - plc.htm hmi setting: parameters recommend ed option s notes plc type omron host link plc i/f rs232 rs232, rs422, rs485 baud rate 9600 9600, 19200 data b its 7 7 or 8 parity even even, odd, none stop b its 2 1 or 2 plc s t a . n o. 0 0 - 31 host link station no. online s imulator yes broadcast command yes extend address mode yes plc setting: communication mode host link p rotocol device a ddress: bit/word device t ype format range memo b ir dddddd 0 ~ 409515 i/o and i nternal relay b hr dddddd 0 ~ 409515 hold relay b lr dddddd 0 ~ 409515 link relay b ir (force s et/reset) dddddd 0 ~ 409515 b hr (force set/reset) dddddd 0 ~ 409515 b lr (force s et/reset) dddddd 0 ~ 409515 b ar ddd ddd 0 ~ 409515 auxiliary relay w ar_w dddd 0 ~ 4095 w ir_w dddd 0 ~ 4095 w hr_w dddd 0 ~ 4095 w lr_w dddd 0 ~ 4095 w tc ddd 0 ~ 255 w dm dddd 0 ~ 9999 data r egister www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 423 wiring d iagram: the following represents the view of hmi & plc. cpu port (cpm2a ,cqm1/1h,c200h/hs/alpha series) communication module: cpm1 - cif01 adapter (for cpm1/cpm1a/cpm2a series, cqm1/cqm1h series) cpm1h - scb41 communication module (for cqm1h - cpu51/61) e mt 3 000 series com1 rs232 9p d - sub fem ale com 3 rs232 9p d - sub fem ale rs232 9p d - sub male 2 rx 8 rx 2 s d 3 tx 7 tx 3 r d 5 gnd 5 gnd 9 gnd 4 rs circuit 5 cs mt6000 /8000 series except mt6050i/mt8050i com1 rs232 9p d - sub fem ale com2 rs232 9p d - sub fem ale com3 rs232 9p d - sub m ale rs232 9p d - sub male 2 rx 6 rx 8 rx 2 s d 3 tx 4 tx 7 tx 3 r d 5 gnd 5 gnd 5 gnd 9 gnd 4 rs circuit 5 cs www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 424 mt6050i/mt8050i com1 rs232 9p d - sub fem ale rs232 9p d - sub male 9 rx 2 s d 6 tx 3 r d 5 gnd 9 gnd 4 rs circuit 5 cs the following represents the vi ew of hmi & plc. c200h - lk201,3g2a6 - lk201 communication module c200hw - com02/03/04/05/06 communication module e mt 3 000 series com1 rs232 9p d - sub fem ale com 3 rs232 9p d - sub fem ale rs232 9p d - sub male 2 rx 8 rx 2 s d 3 tx 7 tx 3 r d 5 gnd 5 gnd 7 gnd 4 rs circuit 5 cs mt6000 /8000 series except mt6050i/mt8050i com1 rs232 9p d - sub fem ale com2 rs232 9p d - sub fem ale com3 rs232 9p d - sub m ale rs232 9p d - sub male 2 rx 6 rx 8 rx 2 s d 3 tx 4 tx 7 tx 3 r d 5 gnd 5 gnd 5 gnd 7 gnd 4 rs circuit 5 cs www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 425 mt6050i/mt8050i com1 rs232 9p d - sub fem ale rs232 9p d - sub male 9 rx 2 s d 6 tx 3 r d 5 gnd 7 gnd 4 rs circuit 5 cs driver version : version date description v1. 30 oct/21/2010 www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 426 panasonic fp supported s eries: nais (matsushita) fp series include fp - x, fp - , fp0, fp1, fp2, fp2sh, fp10sh and fp3 ethernet support fp - x with afpx - com5. website: http://pewa.panasonic.com/ hmi setting: parameters recommend ed option s notes plc type panasonic fp plc i/f rs232 rs232/rs485 baud rate 9600 9600, 19200, 38400, 57600, 115200 data b its 8 7 or 8 parity odd even, odd, none stop b its 1 1 or 2 plc s t a . n o. 1 0 - 255 must match the plc port setting. fp3 must set to 0. device a ddress: bit/word device t ype format ra nge memo b x ddddh 0 ~ 9999 f input (x) b y ddddh 0 ~ 9999 f output (y) b r ddddh 0 ~ 9999 f internal relay (r) b l dddd 0 ~ 9999 link relay (l) b l_bit ddddh 0 ~ 9999 f b t dddd 0 ~ 9999 timer (t) b c dddd 0 ~ 9999 counter (c) w sv dddd 0 ~ 9999 time r/counter s et v alue (sv) w ev ddddd 0 ~ 65535 timer/counter e lapse v alue (ev) w dt ddddd 0 ~ 99999 data register (dt) w ld dddd 0 ~ 8447 link register (ld) w wx dddd 0 ~ 9999 input ( w x) (read only) w wy dddd 0 ~ 9999 output ( w y) w wr dddd 0 ~ 9999 i nternal relay ( w r) w wl dddd 0 ~ 9999 link relay ( w l) w fl ddddd 0 ~ 99999 file r egister (fl) www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 427 wiring d iagram: the following represents the view of hmi & plc. fp0, fp2, fp2sh, fpm cpu : 9p d - sub to 5 p mini - din e mt 3 000 series com1 rs232 9p d - sub fem ale co m 3 rs232 9p d - sub fem ale rs232 5 p m ini - din male 2 rx 8 rx 2 t xd 3 tx 7 tx 3 r xd 5 gnd 5 gnd 1 gnd mt6000 /8000 series except mt6050i/mt8050i com1 rs232 9p d - sub fem ale com2 rs232 9p d - sub fem ale com3 rs232 9p d - sub m ale rs232 5 p m ini - din mal e 2 rx 6 rx 8 rx 2 t xd 3 tx 4 tx 7 tx 3 r xd 5 gnd 5 gnd 5 gnd 1 gnd mt6050i/mt8050i com1 rs232 9p d - sub fem ale rs232 5 p m ini - din male 9 rx 2 t xd 6 tx 3 r xd 5 gnd 1 gnd www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 428 the following represents the view of hmi & plc. fp0 cp u : 9p d - sub to 3 p terminal : e mt 3 000 series com1 rs232 9p d - sub fem ale com 3 rs232 9p d - sub fem ale rs232 3 p terminal 2 rx 8 rx s 3 tx 7 tx r 5 gnd 5 gnd g mt6000 /8000 series except mt6050i/mt8050i com1 rs232 9p d - sub fem ale com2 rs232 9p d - sub fem ale com3 rs232 9p d - sub m ale rs232 3 p terminal 2 rx 6 rx 8 rx s 3 tx 4 tx 7 tx r 5 gnd 5 gnd 5 gnd g mt6050i/mt8050i com1 rs232 9p d - sub fem ale rs232 3 p terminal 9 rx s 6 tx r 5 gnd g www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 429 the following represents the vi ew of hmi & plc. e mt 3 000 series com1 rs232 9p d - sub fem ale com 3 rs232 9p d - sub fem ale rs232 9p d - sub male 2 rx 8 rx 2 t x d 3 tx 7 tx 3 r x d 5 gnd 5 gnd 7 gnd 4 rts circuit 5 cts 8 cd circuit 9 er mt6000 /8000 series except mt 6050i/mt8050i com1 rs232 9p d - sub fem ale com2 rs232 9p d - sub fem ale com3 rs232 9p d - sub m ale rs232 9p d - sub male 2 rx 6 rx 8 rx 2 t x d 3 tx 4 tx 7 tx 3 r x d 5 gnd 5 gnd 5 gnd 7 gnd 4 rts circuit 5 cts 8 cd circuit 9 er www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 430 mt6050i/mt8050 i com1 rs232 9p d - sub fem ale rs232 9p d - sub male 9 rx 2 t x d 6 tx 3 r x d 5 gnd 7 gnd 4 rts circuit 5 cts 8 cd circuit 9 er the following represents the view of hmi & plc. fp1 cpu : 9p d - sub to 8p minidin e mt 3 000 series com1 rs48 5 4 w 9p d - sub m ale rs485 4w 8p hirose male 1 rx - 2 tx da 2 r x + 5 tx db 3 tx - 3 rx da 4 tx+ 6 rx db 5 gnd 1 gnd www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 431 mt6000 /8000 series except mt6050i/mt8050i com1 rs485 4 w 9p d - sub m ale rs485 4w 8p hirose male 1 rx - 2 tx da 2 r x + 5 tx db 3 tx - 3 rx da 4 tx+ 6 rx db 5 gnd 1 gnd mt6050i/mt8050i com1 rs485 4 w 9p d - sub fem ale rs485 4w 8p hirose male 1 rx - 2 tx da 2 r x + 5 tx db 3 tx - 3 rx da 4 tx+ 6 rx db 5 gnd 1 gnd www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 432 the following represents the view of hmi & plc. fp3 cpu : 9p d - sub to 15p d - sub e mt 3 000 series com1 rs485 4 w 9p d - sub m ale rs485 4w 15p d - sub male 1 rx - 9 tx da 2 r x + 2 tx db 3 tx - 1 0 rx da 4 tx+ 3 rx db 5 gnd 7 gnd 4 rts+ circuit 5 cts+ 11 rts - circuit 12 cts - mt6000 /8000 series except mt6050i/mt8050i com1 rs485 4 w 9p d - sub m ale rs485 4w 15p d - sub male 1 rx - 9 tx da 2 r x + 2 tx db 3 tx - 1 0 rx da 4 tx+ 3 rx db 5 gnd 7 gnd 4 rts+ circuit 5 cts+ 11 rts - circuit 12 cts - www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 433 mt6050i /mt8050i com1 rs485 4 w 9p d - sub fem ale rs485 4w 15p d - sub male 1 rx - 9 tx da 2 r x + 2 tx db 3 tx - 1 0 rx da 4 tx+ 3 rx db 5 gnd 7 gnd 4 rts+ circuit 5 cts+ 11 rts - circuit 12 cts - driver version : version date description v1 .80 apr/ 09 /2010 add ed registers: fl www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 434 p anasonic fp ( ethernet ) supported s eries: nais (matsushita) fp series include fp - x, fp - , fp0, fp1, fp2, fp2sh, fp10sh and fp3 ethernet support fp - x with afpx - com5. website: http://pewa.panasonic.com/ hmi setting: parameters recommend ed option s notes plc type panasonic fp (ethernet) plc i/f ethernet port n o. 9094 plc s t a . n o. 1 0~255 device a ddress: bit/word device t ype format range memo b x ddddh 0 ~ 9999 f inpu t (x) b y ddddh 0 ~ 9999 f output (y) b r ddddh 0 ~ 9999 f internal relay (r) b l dddd 0 ~ 9999 link relay (l) b l_bit ddddh 0 ~ 9999 f b t dddd 0 ~ 9999 timer (t) b c dddd 0 ~ 9999 counter (c) w sv dddd 0 ~ 9999 timer/counter s et v alue (sv) w ev ddd dd 0 ~ 65535 timer/counter e lapse v alue (ev) w dt ddddd 0 ~ 99999 data register (dt) w ld dddd 0 ~ 8447 link register (ld) w wx dddd 0 ~ 9999 input ( w x) (read only) w wy dddd 0 ~ 9999 output ( w y) w wr dddd 0 ~ 9999 internal relay ( w r) w wl dddd 0 ~ 9999 link relay ( w l) w fl ddddd 0 ~ 99999 file r egister (fl) www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 435 wiring d iagram: direct connect (crossover cable): hmi rj45 male wire color wire color plc rj45 male 1 tx+ white/orange white/green 3 rx+ 2 tx - orange green 6 rx - 3 rx+ white/green white/or ange 1 tx+ 4 bd4+ blue blue 4 bd4+ 5 bd4 - white/blue white/blue 5 bd4 - 6 rx - green orange 2 tx - 7 bd3+ white/brown white/brown 7 bd3+ 8 bd3 - brown brown 8 bd3 - through a hub: hmi rj45 male wire color wire color plc rj45 male 1 tx+ white/orange white/orange 1 tx+ 2 tx - orange orange 2 tx - 3 rx+ white/green white/green 3 rx+ 4 bd4+ blue blue 4 bd4+ 5 bd4 - white/blue white/blue 5 bd4 - 6 rx - green green 6 rx - 7 bd3+ white/brown white/brown 7 bd3+ 8 bd3 - brown brown 8 bd3 - ethernet c onn ect ion tcp p ort: 9094 ethernet mt8000 afpx - com5 rs232 fp - x www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 436 driver version : version date description v 1.80 apr / 12 / 2010 www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 437 p anasonic fp2 (ethernet) supported s eries: nais (matsushita) fp 2 series include fp2, fp2sh, and fp10sh cpu. website: http://pewa.panasonic.com/ hmi setting: parameters recommend ed option s notes plc type panasonic fp2 (ethernet) plc i /f ethernet port n o. 8500 plc s t a . n o. 2 0~255 device a ddress: bit/word device t ype format range memo b x ddddh 0 ~ 9999 f input (x) b y ddddh 0 ~ 9999 f output (y) b r ddddh 0 ~ 9999 f internal relay (r) b l dddd 0 ~ 9999 link relay (l) b l_bit ddddh 0 ~ 9999 f b t dddd 0 ~ 9999 timer (t) b c dddd 0 ~ 9999 counter (c) w sv dddd 0 ~ 9999 timer/counter s e t v alue (sv) w ev ddddd 0 ~ 65535 timer/counter e lapse v alue (ev) w dt ddddd 0 ~ 99999 data register (dt) w ld dddd 0 ~ 8447 link register (ld) w wx dddd 0 ~ 9999 input ( w x) (read only) w wy dddd 0 ~ 9999 output ( w y) w wr dddd 0 ~ 9999 internal rela y ( w r) w wl dddd 0 ~ 9999 link relay ( w l) www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 438 wiring d iagram: direct connect (crossover cable): hmi rj45 male wire color wire color plc rj45 male 1 tx+ white/orange white/green 3 rx+ 2 tx - orange green 6 rx - 3 rx+ white/green white/orange 1 tx+ 4 bd4+ blue blue 4 bd4+ 5 bd4 - white/blue white/blue 5 bd4 - 6 rx - green orange 2 tx - 7 bd3+ white/brown white/brown 7 bd3+ 8 bd3 - brown brown 8 bd3 - through a hub: hmi rj45 male wire color wire color plc rj45 male 1 tx+ white/orange white/orange 1 tx+ 2 tx - orange orange 2 tx - 3 rx+ white/green white/green 3 rx+ 4 bd4+ blue blue 4 bd4+ 5 bd4 - white/blue white/blue 5 bd4 - 6 rx - green green 6 rx - 7 bd3+ white/brown white/brown 7 bd3+ 8 bd3 - brown brown 8 bd3 - driver version : version date de scription v 1.00 mar / 1 1 / 2010 driver released . www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 439 p anasonic minas a4 supported s eries: panasonic minas a4 series servo drive . hmi setting: parameters recommend ed option s notes plc type panasonic minas a4 plc i/f rs232 baud rate 9600 2400 ~ 57600 data b its 8 parity none stop bits 1 axis n o. 0 (master station only) 0 ~ f (slave) device a ddress: bit/word device t ype format range memo b command 20 d 0 ~ 7 states (note 3) b command 27 dd 0 ~ 31 i nput s ignal (note 3) b command 28 dd 0 ~ 3 1 o utput s ignal (note 3) w command 01 d 0 cpu v ersion (numeric format:16 - bit hex) w command 05 dd 0 ~ 11 d river v ersion (ascii / 12 words) w command 06 dd 0 ~ 11 m otor v ersion (ascii / 12 words) w command 21 d 0 ~ 1 command pulse counter (numeric forma t: 32 - bit signed ) w command 22 d 0 ~ 1 feedback pulse counter (numeric format: 32 - bit signed ) w command 24 d 0 present speed (numeric format: 16 - bit unsigned) w command 25 d 0 present torque (numeric format: 16 - bit unsigned) w command 26 d 0 ~ 1 prese nt deviation counter (numeric format: 32 - bit signed ) w command 84 d 0 write parameter to eeprom (note 1) www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 440 bit/word device t ype format range memo w command 90 d 0 present alarm data (numeric format: 16 - bit unsigned) w command 91 dd 1 ~ 14 alarm history (note 4) (numeric format: 16 - bit unsigne d) w command 92 dd 1 ~ 14 batch alarm (note 4) (numeric format: 16 - bit unsigned) w command 93 d 0 clear a larm h istory (include eeprom) (note 1) w command 94 d 0 a larm c lear (note 1) w command 9b d 0 absolute c lear (note 1) w parameter hh 0 ~ 7f indivi dual parameter (range: 0x00 ~ 0x7f) (note 2) w comm2d_s d 0 ~ 1 command 2d signle turn data (numeric format: 32 - bit s igned) w comm2d_m d 0 ~ 1 command 2d multi - turn data (numeric format: 32 - bit s igned) note: 1. command 84, command 93, command 94 , and comm and 9b are write only. ( these commands are able to use set bit object and execute the write command after trigger ing set bit object.). commands other than these four are read only. 2. parameter read/write : use d evice type to define address control from 00~7f . for example: address_00 is mapping to parameter_00 . (please refer to panasonic minas a4 s eries u ser m anual. ) 3. device address type can define m inas a4 driver s command list. command 20 , command 27 , and command 28 are bit type, use operating range to map communication order status. for example: command 20_3 means read state _ccw . (please refer to panasonic minas a4 s eries u ser m anual.) 4. command 91 and command 92 are word type, use operating range to map the record of 14 alarms. for example : comm and 91_1 means read alarm data_first alarm . www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 441 wiring d iagram: the following represents the view of hmi & plc. minas a4 driver cnx4 port e mt 3 000 series com1 rs232 9p d - sub fem ale com 3 rs232 9p d - sub fem ale rs232 8p m ini - din male 2 rx 8 rx 3 t xd 3 tx 7 tx 5 r xd 5 gnd 5 gnd 4 gnd mt6000 /8000 series except mt6050i/mt8050i com1 rs232 9p d - sub fem ale com2 rs232 9p d - sub fem ale com3 rs232 9p d - sub m ale rs232 8p m ini - din male 2 rx 6 rx 8 rx 3 t xd 3 tx 4 tx 7 tx 5 r xd 5 gnd 5 gnd 5 gnd 4 gnd mt6050i/mt8050i com1 rs232 9p d - sub fem ale rs232 8p m ini - din male 9 rx 3 t xd 6 tx 5 r xd 5 gnd 4 gnd minas a4 driver cnx3 p ort minas a4 driver cnx4 p ort 3 tx 5 rx 4 gnd 4 gnd 7 d - 7 d - 8 d+ 8 d+ 8p mini - din m ale minas a4 driver cnx3 / cnx4 p ort www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 442 rs485 cable / dvop1970 - 005 minas a4 driver 8p m ini - din male minas a4 driver 8p m ini - din male 7 d - 7 d - 8 d+ 8 d+ 4 gnd 4 gnd rs232 cable / dvop1960 minas a4 driver 9p d - sub female minas a4 driver 8p m ini - din male 3 rxd 5 rxd 2 txd 3 txd 5 gnd 4 gnd ` hmi connect with one device hmi connect with multi devices driver version : version date description v1. 1 0 jan/11/2010 v1.20 jul/25/2012 added registers comm2d_s and comm2d_m. www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 443 p anasonic minas a 5 supported s eries: panasonic minas a 5 series servo drive . hmi setting: parameters recommend ed option s notes plc type panas onic minas a 5 plc i/f rs232 rs232/rs485 2w baud rate 9600 2400 ~115200 data b its 8 parity none stop bits 1 axis n o. 0 (master station only) 0 ~ 127 (slave) * when connecting with more than two devices, it is recommended to set timeout to more than 4 seconds. set a longer timeout when connecting with more devices to maintain g ood communication. device a ddress: bit/word device t ype format range memo b command 20 d 0 ~ 7 states (note 3) b command 27 dd 0 ~ 31 i nput s ignal (note 3) b command 28 dd 0 ~ 31 o utput s ignal (note 3) w command 01 d 0 cpu v ersion (numeric format:16 - b it hex) w command 05 dd 0 ~ 11 d river v ersion (ascii / 12 words) w command 06 dd 0 ~ 11 m otor v ersion (ascii / 12 words) w command 21 d 0 ~ 1 command pulse counter (numeric format: 32 - bit signed ) w command 22 d 0 ~ 1 feedback pulse counter (numeric for mat: 32 - bit signed ) w command 24 d 0 present speed (numeric format: 16 - bit unsigned) w command 25 d 0 present torque (numeric format: 16 - bit unsigned) www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 444 bit/word device t ype format range memo w command 26 d 0 ~ 1 present deviation counter (numeric format: 32 - bit signed ) w command 72 d 0 writ e parameter to eeprom (note 1) w command 90 d 0 present alarm data (numeric format: 16 - bit unsigned) w command 92 dd 1 ~ 14 batch alarm (note 4) (numeric format: 16 - bit unsigned) w command 93 d 0 clear a larm h istory (include eeprom) (note 1) w command 94 d 0 a larm c lear (note 1) w command 9b d 0 absolute c lear (note 1) w parameter hh h 0 ~ 639 individu al parameter (range: 0x00 0 ~ 0x 639 ) (note 2) note: 1. command 72 , command 93, command 94 , and command 9b are write only. (these commands are able to use set bit object and execute the write command after trigger ing set bit object.). commands other than these four are read only. 2. parameter read/write: use d evice type to define address control from 00 0 ~ 639 . for example: address_0 0 0 is mapping to parameter_ 0 0 0 . (please refer to panasonic minas a 5 s eries u ser m anual.) 3. device address type can define m inas a 5 drivers command list. command 20, command 27 , and command 28 are bit type, use operating range to map communication order status. for example: com mand 20_3 means read state_ccw . (please refer to pana sonic minas a 5 s eries u ser m anual.) 4. command 92 are word type, use operating range to map the record of 14 alarms. www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 445 wiring d iagram: the following represents the view of hmi & plc. minas a5 driver x2 port rs232 signal e mt 3 000 series com1 rs232 9p d - sub fem ale com 3 rs232 9p d - sub fem ale rs232 8p connector 2 rx 8 rx 3 t xd 3 tx 7 tx 4 r xd 5 gnd 5 gnd 1 gnd mt6000 /8000 series except mt6050i/mt8050i com1 rs232 9p d - sub fem ale com2 rs232 9p d - sub fem ale com3 rs232 9p d - sub m ale rs232 8p connector 2 rx 6 rx 8 rx 3 t xd 3 tx 4 tx 7 tx 4 r xd 5 gnd 5 gnd 5 gnd 1 gnd mt6050i/mt8050i com1 rs232 9p d - sub fem ale rs232 8p connector 9 rx 3 t xd 6 tx 4 r xd 5 gnd 1 gnd www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 446 the following represents the view of hmi & plc. minas a5 driver x2 port rs485 signal e mt 3 000 series com1 rs485 2 w 9p d - sub m ale com 3 rs485 2 w 9p d - sub m ale rs 485 2w 8p connector 1 rx - 6 data - 5,7 485 - 2 rx+ 9 data+ 6,8 485+ 5 gnd 5 gnd 1 gnd mt6000 /8000 series except mt6050i/mt8050i com1 rs485 2 w 9p d - sub m ale com 3 rs485 2 w 9p d - sub m ale rs 485 2w 8p connector 1 rx - 6 data - 5,7 485 - 2 rx+ 9 data+ 6,8 485+ 5 gnd 5 gnd 1 gnd mt6050i/mt8050i com1 rs485 2 w 9p d - sub fem ale com 3 rs485 2 w 9p d - sub fem ale rs 485 2w 8p connector 1 rx - 7 data - 5,7 485 - 2 rx+ 8 data+ 6,8 485+ 5 gnd 5 gnd 1 gnd driver version : versio n date description v1. 0 0 may/23/2012 driver released . www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 447 parker acr9000 supported s eries: parker acr9000 . website: http://www.parkermotion.com hmi setting: parameters recommend ed option s notes plc type parke r acr9000 plc i/f rs232 rs485 4w / rs232 baud rate 38400 1200 - 38400 data b its 8 7,8 parity none even, odd, none stop b its 1 1,2 plc s t a . n o. 0 online s imulator yes extend address mode device a ddress: bit/word device t ype format range m emo b p_low16bit ddddddd 0 ~ 9999915 b p_high16bit ddddddd 0 ~ 9999915 w p_int32 ddddd 0 ~ 99999 w p_float ddddd 0 ~ 99999 www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 448 wiring d iagram: the following represents the view of hmi & plc. e mt 3 000 series com1 rs232 9p d - sub fem ale com 3 rs232 9p d - sub fem ale parker ac9000 rs232 9p d - sub male 2 rx 8 rx 3 t xd 3 tx 7 tx 2 r xd 5 gnd 5 gnd 5 gnd mt6000 /8000 series except mt6050i/mt8050i com1 rs232 9p d - sub fem ale com2 rs232 9p d - sub fem ale com3 rs232 9p d - sub m ale parker ac9000 rs232 9p d - sub male 2 rx 6 rx 8 rx 3 t xd 3 tx 4 tx 7 tx 2 r xd 5 gnd 5 gnd 5 gnd 5 gnd mt6050i/mt8050i com1 rs232 9p d - sub fem ale parker ac9000 rs232 9p d - sub male 9 rx 3 t xd 6 tx 2 r xd 5 gnd 5 gnd driver version: version date descri ption v1.00 dec /30/2008 driver released . www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 449 parker compax3 suppor ted s eries: parker compax3 servo drive . website: http://www.parker.com hmi setting: rs232 parameters recommend ed option s notes plc type parker compa x3 plc i/f rs 232 baud rate 115200 data b its 8 7 or 8 parity none even, odd, none stop b its 1 1 or 2 plc s t a . n o. 0 0 must be 0 for rs232 rs485 parameters recommend ed option s notes plc type parker compax3 plc i/f rs 485 2w baud rate 960 0 data b its 8 7 or 8 parity none even, odd, none stop b its 1 1 or 2 plc s t a . n o. 1 1 - 99 range from 1 to 99 f or rs485, according to the plc setting. www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 450 plc setting: how to set compax 3 servo to rs485 mode? 1. open c3 servomanager2, select communicati on => rs - 485 settings. 2. click to configure rs - 485/pop settings. 3. set parameters as below : www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 451 4. download settings to compax3 servo. 5. set e asy b uilder system parameter and connect with plc for communication of h mi and servo. device a ddress: bit/word device t ype format range memo b r _ low16bit ddddddddh 0 ~ 99999999 f b r_high16bit ddddddddh 0 ~ 99999999f d w register_int dddddd 0 ~ 999999 for register int32 , u32 d w register_float dddddd 0 ~ 999999 for registe r int32 , u32 w register_short dddddd 0 ~ 999999 for register int16 , u16 wiring d iagram: the following represents the view of hmi & plc. parker compax3 plc x10 : rs232 e mt 3 000 series com1 rs232 9p d - sub fem ale com 3 rs232 9p d - sub fem ale rs232 9p d - sub m ale 2 rx 8 rx 3 t xd 3 tx 7 tx 2 r xd 5 gnd 5 gnd 5 gnd mt6000 /8000 series except mt6050i/mt8050i com1 rs232 9p d - sub fem ale com2 rs232 9p d - sub fem ale com3 rs232 9p d - sub m ale rs232 9p d - sub male 2 rx 6 rx 8 rx 3 t xd 3 tx 4 tx 7 tx 2 r xd 5 gnd 5 gnd 5 gnd 5 gnd www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 452 mt6050i/mt8050i com1 rs232 9p d - sub fem ale rs232 9p d - sub male 9 rx 3 t xd 6 tx 2 r xd 5 gnd 5 gnd the following represents the view of hmi & plc. parker compax3 plc x10 : rs485 2w e mt 3 000 series com1 rs 485 2 w 9p d - sub m ale com 3 rs485 2 w 9p d - sub m ale rs 485 2w 9p d - sub male 1 rx - 6 data - 3 rxd 2 rx+ 9 data+ 7 txd 5 gnd 5 gnd 5 gnd 1 nable rs485 circuit 9 +5v mt6000 /8000 series except mt6050i/mt8050i com1 rs485 2 w 9p d - sub m ale com 3 rs 485 2 w 9p d - sub m ale rs 485 2w 9p d - sub male 1 rx - 6 data - 3 rxd 2 rx+ 9 data+ 7 txd 5 gnd 5 gnd 5 gnd 1 nable rs485 circuit 9 +5v www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 453 mt6050i/mt8050i com1 rs485 2 w 9p d - sub fem ale com 3 rs485 2 w 9p d - sub fem ale rs 485 2w 9p d - sub male 1 rx - 7 data - 3 rxd 2 rx+ 8 data+ 7 txd 5 gnd 5 gnd 5 gnd 1 nable rs485 circuit 9 +5v driver version: version date description v1. 7 0 mar/30/2009 www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 454 parker compumotor 6k series hmi setting: parameters recommended options notes plc typ e parker compumotor 6k series plc i/f rs232 baud rate 9600 data bit s 8 parity none stop bit s 1 plc sta. no. 0 device address : bit/word device type format range memo b varb(l) ddd dd 1 ~ 125 the lower 16 bits data of varb b varb(h) dd d dd 1 ~ 125 the higher 16 bits data of varb d run_prg d 0 dw vari ddd 1 ~ 125 dw var ddd 1 ~ 125 must select single float data mode. wiring diagram : the following represents the view of hmi & plc. e mt 3 000 series com1 rs232 9p d - sub fem ale com 3 rs232 9p d - sub fem ale plc rs232 9p d - sub male 2 rx 8 rx 3 t x 3 tx 7 tx 2 r x 5 gnd 5 gnd 5 gnd www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 455 mt6000 /8000 series except mt6050i/mt8050i com1 rs232 9p d - sub fem ale com2 rs232 9p d - sub fem ale com3 rs232 9p d - sub m ale plc rs232 9p d - sub male 2 rx 6 rx 8 rx 3 t x 3 tx 4 tx 7 tx 2 r x 5 gnd 5 gnd 5 gnd 5 gnd mt6050i/mt8050i com1 rs232 9p d - sub fem ale plc rs232 9p d - sub male 9 rx 3 t x 6 tx 2 r x 5 gnd 5 gnd driver version : version date description v1.0 0 apr / 7 /20 11 driv er released. www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 456 p arker slvd ser ies supported s eries : parker slvd servo, slvd1n, slvd2n, slvd5n, slvd7n, slvd10n, slvd15n, slvd17n. website: http://www.parker.com/portal/site/parker/ hmi setting: parameters recommend ed option s notes plc type parker slvd series plc i/f rs485 4 w baud rate 9600 9600 / 19200 data b its 8 7,8 parity even even, odd, none stop b its 1 1,2 plc s t a . n o. 0 0 - 31 online s imulator yes extend address mode device a ddress: bit/word device t ype format range memo b par_binary dddddd 0 ~ 999915 set bit p arameter w par_one_word ddd d 0 ~ 9999 set 2 bytes p arameter dw par_two_word ddd d 0 ~ 9999 set 4 bytes p arameter w par_one_byte ddd d 0 ~ 9999 set 1 byte p rarmeter w reset d 0 w run d 0 www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 457 wiring d iagram: the following represents the view of hmi & plc. parker slvd servo serial link x1 e mt 3 000 series com1 rs485 4 w 9p d - sub m ale rs485 4w 15p d - sub male 1 rx - 7 t x - 2 r x + 12 tx+ 3 tx - 2 rx - 4 tx+ 1 rx+ ci rcuit 6 ter 5 gnd 3 gnd mt6000 /8000 series except mt6050i/mt8050i com1 rs485 4 w 9p d - sub m ale rs485 4w 15p d - sub male 1 rx - 7 t x - 2 r x + 12 tx+ 3 tx - 2 rx - 4 tx+ 1 rx+ circuit 6 ter 5 gnd 3 gnd www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 458 mt6050i/mt8050i com 1 rs485 4 w 9p d - sub fem ale rs485 4w 15p d - sub male 1 rx - 7 t x - 2 r x + 12 tx+ 3 tx - 2 rx - 4 tx+ 1 rx+ circuit 6 ter 5 gnd 3 gnd driver version: version date description v1.00 jan/2 7 /2010 driver released . www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 459 rockwell compactlogix - free tag names w ebsite: http://www.ab.com hmi setting: parameters recommend ed option s notes plc type allen - bradley compactlogix C free tag names plc i/f rs 232 baud rate 19200 9600, 19200, 38400 data b its 8 8 parity none even, odd, none stop b its 1 1 turn around delay (ms) 10 10 ~ 100 *note hmi sta. no. 0 plc sta. no. 1 1 - 31 *note when the communication is not stable, please adjust the parameter of [turn around delay] till the communication is normal. plc setting: communication mode df1 full duplex protocol 19200, none, 8, 1 (default) error check: bcc, station address: 1 1. create n ew tags (controller tags and program tags supported). www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 460 2. export tag data to csv file. ( [ tools ] ? [ export ] ? [ tags and logic comments ] ) note: the separator character in csv file must be a comma , otherwi se the file is invalid . the d irectory of changing system settings: [ control panel ] ? [ date, time, language, and regional options ] ? [ change the format of numbers, dates, and times ] ? [ customize ] ? [ list separator ] . please select , and export csv file after setting. www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 461 3. open easybuil der project file, sele ct the driver and set communication parameter . click [data type] to open [structure editor] and edit the data type of the tags. www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 462 4. in [structure editor] edit the data type of [program t ag] . the imported csv file is shown below: step 1 right click on [ structure editor ] ? [ user - defined ] to add a [ new data type ] . www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 463 step 2 after adding all program tags, click [ok] ? [save] ? [exit] to leave the editor dialog. www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 464 5. in [system parameter settings] , click [import tag] , select the csv file. after importing a message window is displayed. 6. in the object property dialog, select plc tag address. www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 465 device a ddress: plc d ata type name bit/word e asy b uilder data f ormat memo bool boolean bit object bitarray sint int integer 16 - bit signed, ascii - 32768 ~ 32767 dint double integer 32 - bit signed - 2 31 ~ (2 31 - 1) real single precision float 32 - bit float ieee 754 wiring d iagram: the following represents the view of hmi & plc . e mt 3 000 series com1 rs232 9p d - sub fem ale com 3 rs232 9p d - sub fem ale ab cpu ch0 rs232 9p d - sub female 2 rx 8 rx 3 t d 3 tx 7 tx 2 r d 5 gnd 5 gnd 5 gnd mt6000 /8000 series except mt6050i/mt8050i com1 rs232 9p d - sub fem ale com2 rs232 9p d - sub fem ale com3 rs232 9p d - sub m ale ab cpu ch0 rs232 9p d - sub female 2 rx 6 rx 8 rx 3 t d 3 tx 4 tx 7 tx 2 r d 5 gnd 5 gnd 5 gnd 5 gnd www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 466 mt6050i/mt8050i com1 rs232 9p d - sub fem ale ab cpu ch0 rs232 9p d - sub female 9 rx 3 t d 6 tx 2 r d 5 gnd 5 gnd driver version: version date description v1. 0 0 june / 2 /20 11 driver released . www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 467 rockwell compactlogix/flexlogix supported s eries: rockwell controllogix, compactlogix, fl e xlogix ch0 df1 . website: http://ww w.ab.com hmi setting: parameters recommend ed option s notes plc type allen - bradley compactlogix/flexlogix plc i/f rs232 baud rate 19200 9600, 19200, 38400 data b its 8 8 parity none even, odd, none stop b its 1 1 hmi s t a . n o. 0 plc s t a . n o. 1 1 - 31 plc setting: communication mode df1 full duplex protocol 19200, none, 8, 1 (default) error check: bcc, station address: 1 www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 468 controllogix, compactlogix cpu ch0 setting: create a tag: the name format must be 4 chars . for example: b003, t00 4, c005, n007, and f008. two or three chars are not available. for example : b03 or b3. www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 469 device a ddress: bit/word device t ype format range memo b b_bool fffddddd 0 ~ 25525515 bit data file b n_bool fffddddd 0 ~ 25525515 integer data file bit level (n 7, 10 ~ 255) dw tx.acc fffddd 0 ~ 255255 timer accumulator value (t4, t10 ~ 255) dw tx.pre fffddd 0 ~ 255255 timer preset value (t4, t10 ~ 255) dw nx_int fffddd 0 ~ 255255 integer data file (n7, 10 ~ 255) w bx_int fffddd 0 ~ 255255 bit data file word level dw cx.acc fffddd 0 ~ 255255 counter accumulator value (c5, c10 ~ 255) dw cx.pre fffddd 0 ~ 255255 counter preset value (c5, c10 ~ 255) w f8_real ddd 0 ~ 255 floating point data file (f8) w fx_real fffddd 0 ~ 255255 floating point data file (f0 08, f010 ~ f255) www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 470 wiring d iagram: the following represents the view of hmi & plc. e mt 3 000 series com1 rs232 9p d - sub fem ale com 3 rs232 9p d - sub fem ale ab cpu ch0 rs232 9p d - sub fem ale 2 rx 8 rx 3 t d 3 tx 7 tx 2 r d 5 gnd 5 gnd 5 gnd mt6 000 /8000 series except mt6050i/mt8050i com1 rs232 9p d - sub fem ale com2 rs232 9p d - sub fem ale com3 rs232 9p d - sub m ale ab cpu ch0 rs232 9p d - sub fem ale 2 rx 6 rx 8 rx 3 t d 3 tx 4 tx 7 tx 2 r d 5 gnd 5 gnd 5 gnd 5 gnd mt6050i/mt8050i com1 rs232 9 p d - sub fem ale ab cpu ch0 rs232 9p d - sub fem ale 9 rx 3 t d 6 tx 2 r d 5 gnd 5 gnd driver version : version date description v1. 5 0 dec/30/2008 www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 471 rockwell df1 supported s eries: rockwell micrologix 1000, 1100, 1200, 1400, 1500, slc 5/03, 5 /04, 5/05 . website: http://www.ab.com note: allen - bradley df1 driver uses crc checksum. hmi setting: parameters recommend ed option s notes plc type a llen - b radley df1 plc i/f rs232 baud rate 9600 9600, 19200, 38400 data b its 8 8 parity none even, odd, none stop b its 1 1 hmi s t a . n o. 0 plc s t a . n o. 1 1 - 31 plc setting: communication mode df1 full duplex protocol 19200, none, 8, 1 (default) error check: crc device a ddress: bit/word device t ype format ran ge memo b i1 ddddd 0 ~ 25515 input (i) b o0 ddddd 0 ~ 25515 output (o) b b3 ddddd 0 ~ 25515 bit data file (b3) b b10 ~ 13 ddddd 0 ~ 25515 bit data file (b10 ~ 13) b s_bit ddddd 0 ~ 25515 status (s) bit level b bfn fffddddd 0 ~ 25525515 bit data file (b3, 10 ~ 254) b nfnbit fffddddd 0 ~ 25525515 integer data file bit level (n7, 10 ~ 254) w t4sv ddd 0 ~ 255 timer preset value (t4) w t4pv ddd 0 ~ 255 timer accumulator value (t4) www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 472 bit/word device t ype format ran ge memo w c5sv ddd 0 ~ 255 counter preset value (c5) w c5pv ddd 0 ~ 255 counte r accumulator value (c5) w tfnsv fffddd 0 ~ 255255 timer preset value w tfnpv fffddd 0 ~ 255255 timer accumulator value w c fn sv fffddd 0 ~ 255255 counter preset value w c fn pv fffddd 0 ~ 255255 counter accumulator value w n7 ddd 0 ~ 255 integer data fi le (n7) w n10 ~ 15 ddd 0 ~ 255 integer data file (n10 ~ 15) w nfn fffddd 0 ~ 255255 integer data file (n7, 10 ~ 254) w s ddd 0 ~ 255 status (s) w f8 ddd 0 ~ 255 floating point data file (f8) w ffn fffddd 0 ~ 255255 w lfn fffddd 0 ~ 255255 wiring d iagram: the following represents the view of hmi & plc. 9p d - sub to 8 p mini - din : micrologix 1000, 1100, 1200, 1400, 1500 e mt 3 000 series com1 rs232 9p d - sub fem ale com 3 rs232 9p d - sub fem ale micrologix rs232 8p mini - din male 2 rx 8 rx 7 t xd 3 tx 7 tx 4 r xd 5 gnd 5 gnd 2 gnd www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 473 mt6000 /8000 series except mt6050i/mt8050i com1 rs232 9p d - sub fem ale com2 rs232 9p d - sub fem ale com3 rs232 9p d - sub m ale micrologix rs232 8p mini - din male 2 rx 6 rx 8 rx 7 t xd 3 tx 4 tx 7 tx 4 r xd 5 gnd 5 gnd 5 gnd 2 gnd mt6050i/mt8050i com1 rs232 9p d - sub fem ale micrologix rs232 8p mini - din male 9 rx 7 t xd 6 tx 4 r xd 5 gnd 2 gnd the following represents the view of hmi & plc. 9p d - sub to 9p d - sub: slc5/03, 04, 05 ch0 e mt 3 000 series com1 rs232 9p d - sub fem ale com 3 rs232 9p d - sub fem ale ab cpu ch0 rs232 9p d - sub fem ale 2 rx 8 rx 3 t d 3 tx 7 tx 2 r d 5 gnd 5 gnd 5 gnd www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 474 mt6000 /8000 series except mt6050i/mt8050i com1 rs232 9p d - sub fem ale com2 rs232 9p d - sub fem ale com3 rs232 9p d - sub m ale ab cpu ch0 rs232 9p d - sub fem ale 2 rx 6 rx 8 rx 3 t d 3 tx 4 tx 7 tx 2 r d 5 gnd 5 gnd 5 gnd 5 gnd mt6050i/mt8050i com1 rs232 9p d - sub fem ale ab cpu ch0 rs232 9p d - sub fem ale 9 rx 3 t d 6 tx 2 r d 5 gnd 5 gnd driv er version : version date description v2.20 jan/05/2010 www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 475 rockwell df1 (bcc) supported s eries: rockwell micrologix 1000, 1100, 1200, 1500, slc 5/03, 5/04, 5/05 . website: http://www.ab.com note: allen - bradley df1 ( bcc ) and allen - bradley df1 are the same; the only differen ce is th e use of bcc checksum. hmi setting: parameters recommend ed option s notes plc type a llen - b radley df1 (bcc) plc i/f rs232 baud rate 19200 9600, 19200, 38400 data b its 8 8 parity none ev en, odd, none stop b its 1 1 hmi s t a . n o. 0 plc s t a . n o. 1 1 - 31 plc setting: communication mode df1 full duplex protocol 19200, none, 8, 1 (default) error check: crc device a ddress: bit/word device t ype format range memo b i1 ddddd 0 ~ 25515 i nput (i) b o0 ddddd 0 ~ 25515 output (o) b b3 ddddd 0 ~ 25515 bit data file (b3) b b10 ~ 13 ddddd 0 ~ 25515 bit data file (b10 ~ 13) b s_bit ddddd 0 ~ 25515 status (s) bit level b bfn fffddddd 0 ~ 25525515 bit data file (b3, 10 ~ 254) b nfnbit fffddd dd 0 ~ 25525515 integer data file bit level (n7, 10 ~ 254) w t4sv ddd 0 ~ 255 timer preset value (t4) w t4pv ddd 0 ~ 255 timer accumulator value (t4) www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 476 bit/word device t ype format range memo w c5sv ddd 0 ~ 255 counter preset value (c5) w c5pv ddd 0 ~ 255 counter accumulator value (c5) w tfns v fffddd 0 ~ 255255 timer preset value w tfnpv fffddd 0 ~ 255255 timer accumulator value w c fn sv fffddd 0 ~ 255255 counter preset value w c fn pv fffddd 0 ~ 255255 counter accumulator value w n7 ddd 0 ~ 255 integer data file (n7) w n10~15 ddd 0 ~ 255 in teger data file (n10 ~ 15) w nfn fffddd 0 ~ 255255 integer data file (n7, 10 ~ 254) w s ddd 0 ~ 255 status (s) w f8 ddd 0 ~ 255 floating point data file (f8) w ffn fffddd 0 ~ 255255 w lfn fffddd 0 ~ 255255 wiring d iagram: the following represents the view of hmi & plc. 9p d - sub to 8 p mini - din : micrologix 1000, 1100, 1200, 1500 e mt 3 000 series com1 rs232 9p d - sub fem ale com 3 rs232 9p d - sub fem ale micrologix rs232 8p mini - din male 2 rx 8 rx 7 t xd 3 tx 7 tx 4 r xd 5 gnd 5 gnd 2 gnd www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 477 mt 6000 /8000 series except mt6050i/mt8050i com1 rs232 9p d - sub fem ale com2 rs232 9p d - sub fem ale com3 rs232 9p d - sub m ale micrologix rs232 8p mini - din male 2 rx 6 rx 8 rx 7 t xd 3 tx 4 tx 7 tx 4 r xd 5 gnd 5 gnd 5 gnd 2 gnd mt6050i/mt8050i com1 rs2 32 9p d - sub fem ale micrologix rs232 8p mini - din male 9 rx 7 t xd 6 tx 4 r xd 5 gnd 2 gnd the following represents the view of hmi & plc. 9p d - sub to 9p d - sub: slc5/03, 04, 05 ch0 e mt 3 000 series com1 rs232 9p d - sub fem ale com 3 rs232 9p d - s ub fem ale ab cpu ch0 rs232 9p d - sub fem ale 2 rx 8 rx 3 t d 3 tx 7 tx 2 r d 5 gnd 5 gnd 5 gnd www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 478 mt6000 /8000 series except mt6050i/mt8050i com1 rs232 9p d - sub fem ale com2 rs232 9p d - sub fem ale com3 rs232 9p d - sub m ale ab cpu ch0 rs232 9p d - sub fem ale 2 rx 6 rx 8 rx 3 t d 3 tx 4 tx 7 tx 2 r d 5 gnd 5 gnd 5 gnd 5 gnd mt6050i/mt8050i com1 rs232 9p d - sub fem ale ab cpu ch0 rs232 9p d - sub fem ale 9 rx 3 t d 6 tx 2 r d 5 gnd 5 gnd driver version : version date description v2 .30 apr/26/2010 www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 479 rockwell dh485 supported s eries: rockwell micrologix 1000, 1100, 1200, 1500, slc 5/03, 5/04, 5/05. website: http://www.ab.com hmi setting: parameters recommend ed option s notes plc type allen - bradley dh485 plc i/f rs485 2w rs232 baud rate 19200 9600, 19200 data bits 8 parity even stop bits 1 hmi s t a . n o. 0 2 plc s t a . n o. 1 1 - 31 online simulation yes extend address mode no plc setting: communication mode dh485 protocol 19200 (def ault) set the max. node address to the number of plcs in use. www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 480 device address: bit/word device t ype format range memo b i1 ddddd 0 ~ 25515 input (i) b o0 ddddd 0 ~ 25515 output (o) b b3 ddddd 0 ~ 25515 bit data file (b3) b b10 ~ 13 ddddd 0 ~ 25515 bit data file (b10 ~ 13) b bfn fffddddd 0 ~ 25525515 bit data file (b3, 10 ~ 254) b nfnbit fffddddd 0 ~ 25525515 integer data file bit level (n7,10 ~ 254) b s_bit ddddd 0 ~ 25515 status file w t4sv ddd 0 ~ 255 timer preset value (t4) w t4pv ddd 0 ~ 25 5 timer accumulator value (t4) w c5sv ddd 0 ~ 255 counter preset value (c5) w c5pv ddd 0 ~ 255 counter accumulator value (c5) w tfnsv fffddd 0 ~ 255255 timer preset value w tfnpv fffddd 0 ~ 255255 timer accumulator value w cfnsv fffddd 0 ~ 255255 coun ter preset value w cfnpv fffddd 0 ~ 255255 counter accumulator value w f8 ddd 0 ~ 255 floating point data file (f8) w n7 ddd 0 ~ 255 integer data file (n7) w n10 ~ 15 ddd 0 ~ 255 integer data file (n10 ~ 15) w nfn fffddd 0 ~ 255255 integer data file (n7,10 ~ 254) w s ddd 0 ~ 255 status file www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 481 wiring diagram: the following represents the view of hmi & plc. rs - 485: slc500 fixed type, slc5/01, 02, 03 ch1. hmi cant connect to 1747 - aic peripheral port. e mt 3 000 series com1 rs485 2 w 9p d - sub m ale com 3 rs4 85 2 w 9p d - sub m ale ab slc500 dh485 rj8 male 1 rx - 6 data - 2 sdb 2 rx+ 9 data+ 1 sda 5 gnd 5 gnd 7 gnd mt6000 /8000 series except mt6050i/mt8050i com1 rs485 2 w 9p d - sub m ale com 3 rs485 2 w 9p d - sub m ale ab slc500 dh485 rj8 male 1 rx - 6 data - 2 sdb 2 rx+ 9 data+ 1 sda 5 gnd 5 gnd 7 gnd mt6050i/mt8050i com1 rs485 2 w 9p d - sub fem ale com 3 rs485 2 w 9p d - sub fem ale ab slc500 dh485 rj8 male 1 rx - 7 data - 2 sdb 2 rx+ 8 data+ 1 sda 5 gnd 5 gnd 7 gnd www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 482 9p d - sub to 8 p mini - din : micrologix 1000, 1100, 1200, and 1500 must set dh485 protocol. e mt 3 000 series com1 rs232 9p d - sub fem ale com 3 rs232 9p d - sub fem ale micrologix rs232 8p mini - din male 2 rx 8 rx 7 t xd 3 tx 7 tx 4 r xd 5 gnd 5 gnd 2 gnd mt6000 /8000 series except mt6050i/mt8050i com1 rs232 9p d - sub fem ale com2 rs232 9p d - sub fem ale com3 rs232 9p d - sub m ale micrologix rs232 8p mini - din male 2 rx 6 rx 8 rx 7 t xd 3 tx 4 tx 7 tx 4 r xd 5 gnd 5 gnd 5 gnd 2 gnd mt6050i/mt8050i com1 rs232 9p d - sub fem a le micrologix rs232 8p mini - din male 9 rx 7 t xd 6 tx 4 r xd 5 gnd 2 gnd www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 483 9p d - sub to 9p d - sub: slc5/03, 04, 05 ch0 must set dh485 protocol. e mt 3 000 series com1 rs232 9p d - sub fem ale com 3 rs232 9p d - sub fem ale ab cpu ch0 rs232 9p d - sub f em ale 2 rx 8 rx 3 t d 3 tx 7 tx 2 r d 5 gnd 5 gnd 5 gnd mt6000 /8000 series except mt6050i/mt8050i com1 rs232 9p d - sub fem ale com2 rs232 9p d - sub fem ale com3 rs232 9p d - sub m ale ab cpu ch0 rs232 9p d - sub fem ale 2 rx 6 rx 8 rx 3 t d 3 tx 4 tx 7 tx 2 r d 5 gnd 5 gnd 5 gnd 5 gnd mt6050i/mt8050i com1 rs232 9p d - sub fem ale ab cpu ch0 rs232 9p d - sub fem ale 9 rx 3 t d 6 tx 2 r d 5 gnd 5 gnd driver version : version date description v1.20 apr/17/2009 www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 484 rockwell ethernet/i p (compactlogix) supported s eries: rockwell controllogix , compactlogix, felxlogix ethernet . website: http://www.ab.com hmi setting: parameters recommend ed option s notes plc type allen - bradley ethernet /ip ( compactlogix ) plc i/f ethernet port no. 44818 plc s t a . n o. 1 plc setting: rslogix 5000 setting create a tag: the name format must be 4 chars . for example: b003, t004, c005, n007, and f008. two or three chars are not available. for example: b03 or b3. www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 485 device a ddress: bit/word device t ype format range memo b bx_bool fffddddd 0 ~ 25525515 bit data file b nx_bool fffddddd 0 ~ 25525515 integer data file bit level (n7, 10 ~ 99) w bx_int fffddd 0 ~ 255255 bit data file word level w nx_int fffddd 0 ~ 255255 integer data file (n7, 10 ~ 99) dw ( f ) f8_real ddd 0 ~ 255 floating point data file (f8) dw ( f ) fx_real fffddd 0 ~ 255255 floating point data file (f8) dw cx.acc fffddd 0 ~ 255255 counter accumulator value (c5, c10 ~ 255) dw cx.pre fffddd 0 ~ 255255 counter preset value (c5, c10 ~ 255) dw tx.acc fffddd 0 ~ 255255 timer accumulator value (t4, t10 ~ 255) dw tx.pre fffddd 0 ~ 255255 timer preset value (t4, t10 ~ 255) dw lx.dint fffddd 0 ~ 255255 www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 486 wiring d iagram: direct connect (cro ssover cable): hmi rj45 male wire color wire color plc rj45 male 1 tx+ white/orange white/green 3 rx+ 2 tx - orange green 6 rx - 3 rx+ white/green white/orange 1 tx+ 4 bd4+ blue blue 4 bd4+ 5 bd4 - white/blue white/blue 5 bd4 - 6 rx - green orange 2 tx - 7 bd3+ white/brown white/brown 7 bd3+ 8 bd3 - brown brown 8 bd3 - through a hub: hmi rj45 male wire color wire color plc rj45 male 1 tx+ white/orange white/orange 1 tx+ 2 tx - orange orange 2 tx - 3 rx+ white/green white/green 3 rx+ 4 bd4+ blue blu e 4 bd4+ 5 bd4 - white/blue white/blue 5 bd4 - 6 rx - green green 6 rx - 7 bd3+ white/brown white/brown 7 bd3+ 8 bd3 - brown brown 8 bd3 - driv er version : version date description v1. 30 dec/30/2008 v1.50 mar/6/2012 added register: lx.dint www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 487 rockwe ll ethernet/ip (compactlogix) C free tag names supported s eries: rockwell compactlogix, felxlogix ethernet website: http://www.ab.com hmi setting: parameters recommend ed option s notes plc type allen - bradley ethernet/i p (compactlogix) C free tag names plc i/f ethernet port n o. 44818 plc s t a. n o. 1 plc setting: 1. set plc ip address. www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 488 2. create new tags (controller tags and program tags supported). 3. export tag data to csv file. ( [ tools ] ? [ expo rt ] ? [ tags and logic comments ] ) note: the separator character in csv file must be a comma , otherwi se the file is invalid . the directory of changing system settings: [ control panel ] ? [ date, time, language, and regional options ] ? [ chang e the format of numbers, dates, and times ] ? [ customize ] ? [ list separator ] . please select , and export csv file after setting. www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 489 4. open easybuilder project file, select the driver and set ip address. click [data type] to open [structure editor] and edit the data type of the tags. www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 490 5. in [structure editor] edit the data type of [program tag] . the imported csv file is shown below: step 1 right click on [ structure editor ] ? [ user - defined ] to add a [ new data type ] . www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 491 step 2 after adding all program tags, click [ok] ? [save] ? [exit] to leave the editor dialog. www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 492 6. in [system parameter settings] , click [import tag] , select the csv file. after importing a message window is displayed. 7. in the object property dialog, select plc tag address. www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 493 device a ddress: plc d ata t ype n ame bit/word e asybuilder d ata format memo bool boolean bit object bitarray sint int integer 16 - bit signed, ascii - 32768 ~ 32767 dint double integer 32 - bit signed - 2 31 ~ (2 31 - 1) real single precision float 32 - bit float ieee 754 wiring d iagram: direct connect (crossover cable): hmi rj45 male wire color wire color plc rj45 male 1 tx+ white/orange white/green 3 rx+ 2 tx - orange green 6 rx - 3 rx+ white/green whit e/orange 1 tx+ 4 bd4+ blue blue 4 bd4+ 5 bd4 - white/blue white/blue 5 bd4 - 6 rx - green orange 2 tx - 7 bd3+ white/brown white/brown 7 bd3+ 8 bd3 - brown brown 8 bd3 - www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 494 through a hub: hmi rj45 male wire color wire color plc rj45 male 1 tx+ white/o range white/orange 1 tx+ 2 tx - orange orange 2 tx - 3 rx+ white/green white/green 3 rx+ 4 bd4+ blue blue 4 bd4+ 5 bd4 - white/blue white/blue 5 bd4 - 6 rx - green green 6 rx - 7 bd3+ white/brown white/brown 7 bd3+ 8 bd3 - brown brown 8 bd3 - driver version : version date description v1.10 aug/25/2010 www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 495 rockwell ethernet/ip (controllogix) C free tag names supported s eries: rockwell controllogix, compactlogix, felxlogix ethernet . website: http://www.ab.com hmi setting: parameters recommend ed option s notes plc type allen - bradley ethernet/ip (co ntrol logix) C free tag names plc i/f ethernet port n o. 44818 plc s t a . n o. the same as cpu slot no. plc setting: 1. set plc ip address. www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 496 2. create new tags (contro ller tags and program tags supported). 3. export tag data to csv file. ( [ tools ] ? [ export ] ? [ tags and logic comments ] ) note: the separator character in csv file must be a comma , otherwi se the file is invalid . the directo ry of changing system settings: [ control panel ] ? [ date, time, language, and regional options ] ? [ change the format of numbers, dates, and times ] ? [ customize ] ? [ list separator ] . please select , and export csv file after setting. www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 497 4. open easybuilder pr oject file, select the driver and set ip address. click [data type] to open [structure editor] and edit the data type of the tags. www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 498 5. in [structure editor] edit the data type of [program tag] . the imported c sv file is shown below: step 1 right click on [ structure editor ] ? [ user - defined ] to add a [ new data type ] . www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 499 step 2 after adding all program tags, click [ok] ? [save] ? [exit] to leave the editor dialog. www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 500 6. in [system parameter settings] , click [import tag] , select the csv file. after importing a message window is displayed. 7. in the object property dialog, select plc tag address. www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 501 device a ddress: plc d ata t ype n ame bit/word e asybuilder d ata format memo bool boolean bit object bitarray sint int integer 16 - bit signed, ascii - 32768 ~ 32767 dint double integer 32 - bit signed - 2 31 ~ (2 31 - 1) real single precision float 32 - bit float ieee 754 wiring d iagram: direct connect (crossover cable): hmi rj45 m ale wire color plc rj4 5 m ale 1 tx+ white/orange 3 rx+ 2 tx - orange 6 rx - 3 rx+ white/green 1 tx+ 4 bd4+ blue 4 bd4+ 5 bd4 - white/blue 5 bd4 - 6 rx - green 2 tx - 7 bd3+ white/brown 7 bd3+ 8 bd3 - brown 8 bd3 - through a hub: hmi rj45 m ale wire color plc rj45 m ale 1 t x+ white/orange 1 tx+ 2 tx - orange 2 tx - 3 rx+ white/green 3 rx+ 4 bd4+ blue 4 bd4+ 5 bd4 - white/blue 5 bd4 - 6 rx - green 6 rx - 7 bd3+ white/brown 7 bd3+ 8 bd3 - brown 8 bd3 - www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 502 driver version : version date description v1.10 oct/05/2010 www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 503 rockw ell ethernet/ip (df1) supported s eries: rockwell micrologix 1100 , 1400 , slc5/05 ethernet port. micrologix1000, 1200, 1500, slc 5/03, 5/04 with 1761 - net - eni website: http://www.ab.com hmi setting: parameters recommend ed option s notes plc type allen - bradley ethernet/ip (df1) plc i/f ethernet port n o. 44818 hmi s t a. n o. 0 plc s t a . n o. 1 plc setting: communication mode port setting: 10/100 mbps full duplex/half duplex device a ddress: bit/word device t ype fo rmat range memo b i1 ddddd 0 ~ 25515 input (i) b o0 ddddd 0 ~ 25515 output (o) b b3 ddddd 0 ~ 25515 bit data file (b3) b s_bit dddddddd 0 ~ 25525515 status file b bfn fffddddd 0 ~ 25525515 bit data file (b3, 10 ~ 254) b nfnbit fffddddd 0 ~ 25525515 i nteger data file bit level (n7, 10 ~ 254) w t4sv ddd 0 ~ 255 timer preset value (t4) w t4pv ddd 0 ~ 255 timer accumulator value (t4) w c5sv ddd 0 ~ 255 counter preset value (c5) w c5pv ddd 0 ~ 255 counter accumulator value (c5) w tfnsv fffddd 0 ~ 2552 55 w tfnpv fffddd 0 ~ 255255 w cfnsv fffddd 0 ~ 255255 www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 504 bit/word device t ype fo rmat range memo w cfnpv fffddd 0 ~ 255255 w s ddd 0 ~ 255 w n7 ddd 0 ~ 255 integer data file (n7) w nfn fffddd 0 ~ 255255 integer data file (n7, 10 ~ 254) dw ( f ) f8 ddd 0 ~ 255 floating point data file (f 8) dw ( f ) ffn fffddd 0 ~ 255255 floating point data file (f8, 10 ~ 254) dw lfn fffddd 0 ~ 255255 driver version 2.00 or later support ed wiring d iagram: direct connect (crossover cable): hmi rj45 male wire color wire color plc rj45 male 1 tx+ white/orange white/green 3 rx+ 2 tx - orange green 6 rx - 3 rx+ white/green white/orange 1 tx+ 4 bd4+ blue blue 4 bd4+ 5 bd4 - white/blue white/blue 5 bd4 - 6 rx - green orange 2 tx - 7 bd3+ white/brown white/brown 7 bd3+ 8 bd3 - brown brown 8 bd3 - ethernet crossover cable mt8000 1761 - net - eni micrologix 1000, 1200, 1500, slc 5/03, 5/04 rs232 df1 com cpu pwr www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 505 through a hub: hmi rj45 male wire color wire color plc rj45 male 1 tx+ white/orange white/orange 1 tx+ 2 tx - orange orange 2 tx - 3 rx+ white/green white/green 3 rx+ 4 bd4+ blue blue 4 bd4+ 5 bd4 - whi te/blue white/blue 5 bd4 - 6 rx - green green 6 rx - 7 bd3+ white/brown white/brown 7 bd3+ 8 bd3 - brown brown 8 bd3 - driver version : version date description v2.00 dec/21/2009 add lfn register . s l c 5 0 0 s l c 5 0 0 s l c 5 0 0 m t 8 0 0 0 s w i t c h h u b www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 506 rockwell plc5 website: http://www.ab.com hmi setting: parameters recommend ed option s notes plc type a llen - b radley plc5 plc i/f rs232 baud rate 19200 9600, 19200 data b its 8 8 parity even even, odd, none stop b its 1 1 hmi s t a . n o. 0 plc s t a . n o. 1 1 - 31 plc setting: communication mode df1 full duplex protocol 19200, none, 8, 1 (default) allen - bra dley plc - 5 family plcs u se df1 full duplex protocol. for plc - 5/10, plc - 5/15 and plc - 5/25 , mt8000 should be connected to the df1 port on the 1785 - ke module . f o r plc - 5/11, plc - 5/20, plc - 5/30 and plc - 5/40 , mt8000 should be connected to the channel 0 port o n t he plc. device a ddress: bit/word device t ype format range memo b i1 ddddd 0 ~ 25515 input (i) b o0 ddddd 0 ~ 25515 output (o) b b3 ddddd 0 ~ 999 15 bit dat a file (b3) b b10 ~ 13 ddddd 0 ~ 999 15 bit data file (b10 ~ 13) b s_bit dddddddd 0 ~ 25599915 b bfn fffddddd 0 ~ 25599915 b nfnbit fffddddd 0 ~ 25599915 w t4sv ddd 0 ~ 999 timer preset value (t4) www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 507 bit/word device t ype format range memo w t4pv ddd 0 ~ 999 timer accumulator value (t4) w c5sv ddd 0 ~ 999 counter preset value (c5) w c5pv ddd 0 ~ 999 counter accumulator value (c5) w tfnsv fffddd 0 ~ 255999 w tfnpv fffddd 0 ~ 255999 w cfnsv fffddd 0 ~ 255999 w cfnpv fffddd 0 ~ 255999 w n7 ddd 0 ~ 999 integer data file (n7) w n10 ~ 15 ddd 0 ~ 999 integer data file (n10 ~ 15) w nfn fffddd 0 ~ 255999 integer data file (v2.5.0 or newer) w s ddd 0 ~ 255 w f8 ddd 0 ~ 999 floating point data file (f8) w ffn fffddd 0 ~ 255999 floating point data file (v2.5.0 or newer) wiring d iagram : the following represents the view of hmi & plc. 9p d - sub to 25 p d - sub: plc5 cpu ch0 e mt 3 000 series com1 rs232 9p d - sub fem ale com 3 rs232 9p d - sub fem ale ab cpu ch0 rs232 25 p d - sub male 2 rx 8 rx 3 t d 3 tx 7 tx 2 r d 5 gnd 5 gnd 7 gnd www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 508 mt6 000 /8000 series except mt6050i/mt8050i com1 rs232 9p d - sub fem ale com2 rs232 9p d - sub fem ale com3 rs232 9p d - sub m ale ab cpu ch0 rs232 25 p d - sub male 2 rx 6 rx 8 rx 3 t d 3 tx 4 tx 7 tx 2 r d 5 gnd 5 gnd 5 gnd 7 gnd mt6050i/mt8050i com1 rs232 9p d - sub fem ale ab cpu ch0 rs232 25 p d - sub male 9 rx 3 t d 6 tx 2 r d 5 gnd 7 gnd note: the default error check ing of ab plc5 is bcc, whereas our driver is crc. www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 509 access [ channel configuration ] from rslogix5, under channel 0 tab, please select crc for [ error detect ] . driver version : version date description v1.20 apr/17/2009 www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 510 rs aut omation oemax series supported s eries: oemax nx7/nx7s controllers . website: http://www.oemax.co.kr hmi setting: parameters recommend ed option s notes plc type rs automation oemax series plc i/f rs232 baud rate 9600 9600, 19200, 38400 data b its 8 8 parity none even, odd, none stop b its 1 1 plc s t a . n o. 0 hmi sta. no. 225 0 ~ 255 * please correctly set hmi station number . device a ddress: bit/word device t ype format range memo b r ddddd 0 ~ 25515 b l ddddd 0 ~ 25515 b m dddddd 0 ~ 199915 b k ddddd 0 ~ 25515 keep c ontact b f ddddd 0 ~ 99115 special c ontact b tc ddd 0 ~ 25 5 timer/counter w w dddd 0 ~ 7999 data r egister w s v ddd 0 ~ 25 5 timer/counter set value w p v ddd 0 ~ 25 5 timer/counter pre set value w sr ddd 0 ~ 25 5 special r egister w wr ddd 0 ~ 25 5 w wl ddd 0 ~ 25 5 w wm dddd 0 ~ 1999 w wk ddd 0 ~ 25 5 w wf ddd 0 ~ 991 www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 511 wiring d iagram: the following represents the view of hmi & plc. e mt 3 000 series com1 rs232 9p d - sub fem ale com 3 rs 232 9p d - sub fem ale port1 rs232 9p d - sub male 2 rx 8 rx 2 t xd 3 tx 7 tx 3 r xd 5 gnd 5 gnd 5 gnd mt6000 /8000 series except mt6050i/mt8050i com1 rs232 9p d - sub fem ale com2 rs232 9p d - sub fem ale com3 rs232 9p d - sub m ale port1 rs232 9p d - sub ma le 2 rx 6 rx 8 rx 2 t xd 3 tx 4 tx 7 tx 3 r xd 5 gnd 5 gnd 5 gnd 5 gnd mt6050i/mt8050i com1 rs232 9p d - sub fem ale port1 rs232 9p d - sub male 9 rx 2 t xd 6 tx 3 r xd 5 gnd 5 gnd driver version : version date description v1.00 dec /30/2008 driver released . v1.20 jun/27/2012 support more station numbers. www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 512 saia pcd pgu m ode supported s eries : saia pcd series pgu mode. website : http://www.saia - burgess.com/ hmi setting: parameters recom mend ed option s notes plc type saia pcd pgu mode pds driver plc i/f rs232 rs232, rs485 baud rate 9600 9600, 19200 data b its 7 7,8 parity even even, odd, none stop b its 1 1 plc s t a . n o. 1 0 - 255 device a ddress: bit/word device t ype format range memo b flag dddd 0 ~ 8191 b output ddd 0 ~ 511 b input ddd 0 ~ 511 w register dddd 0 ~ 4095 w counter dddd 0 ~ 1599 w timer dddd 0 ~ 1599 w reg_float dddd 0 ~ 4095 support single float point w reg_word dddd 0 ~ 4095 www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 513 wiring d iagram: the f ollowing represents the view of hmi & plc. e mt 3 000 series com1 rs232 9p d - sub fem ale rs232 9p d - sub male 2 rx 3 t xd 3 tx 2 r xd 5 gnd 5 gnd 7 rts 6 dsr 7 rts circuit 8 cts mt6000 /8000 series except mt6050i/mt8050i com1 rs232 9p d - sub fem ale rs232 9p d - sub male 2 rx 3 t xd 3 tx 2 r xd 5 gnd 5 gnd 7 rts 6 dsr 7 rts circuit 8 cts 6 dsr (of pgu port): pgu connected . driver version : version date description v1.02 dec/30/2008 www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 514 saia pcd s - b us m ode supported s eries: saia pcd series s - bus mode. website: http://www.saia - burgess.com/ hmi setting: parameters recommend ed option s notes plc type saia pcd s - bus mode pds driver plc i/f rs232 rs232, rs485 baud rate 960 0 9600, 19200, 38400 data b its 8 7,8 parity none even, odd, none stop b its 1 1 plc s t a . n o. 0 0 - 255 plc setting: communication mode 9600,n,8,1 (default) rs232 port 0 - type: rs232 rs485 2w s - bus mode: data(s2), port 1 - type: rs485 ? open saia pro ject manager sp2.0.150 and create a new project . www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 515 ? give a project name . create a new project as below . go to online setting . www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 5 16 ? select pgu . go to device configurator . www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 517 click change device type to select your plc model. select rs23 2 (pgu) in type and then right click mouse on onboard communications and select properties . www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 518 select yes in series s - bus port: enabled . ? set parameters in s - bus mode a nd timing then upload to plc. www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 519 11 go to online settin g s >> open to select s - bus for finishing the plc settings. device a ddress: bit/word device t ype format range memo b flag dddd 0 ~ 8191 b output dddd 0 ~ 1023 b input dddd 0 ~ 1023 b reg_bit dddddd 0 ~ 1638331 dd: bit no. (00~31) d w register ddddd 0 ~ 16383 d w cou nter dddd 0 ~ 1599 d w timer dddd 0 ~ 1599 d w reg_float ddddd 0 ~ 16383 support single float point dw dbn dddd dd ddd 0 ~ 536016383 www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 520 wiring d iagram: the following represents the view of hmi & plc. saia pcd pgu port emt3000 series com1 rs232 9p d - sub fe m ale com 3 rs232 9p d - sub fem ale rs232 9p d - sub male 2 rx 8 rx 3 t x d 3 tx 7 tx 2 r x d 5 gnd 5 gnd 5 gnd 7 rts circuit 8 cts mt6000 /8000 series except mt6050i/mt8050i com1 rs232 9p d - sub fem ale com2 rs232 9p d - sub fem ale com3 rs232 9p d - sub m ale rs232 9p d - sub male 2 rx 6 rx 8 rx 3 t x d 3 tx 4 tx 7 tx 2 r x d 5 gnd 5 gnd 5 gnd 5 gnd 7 rts circuit 8 cts mt6050i/mt8050i com1 rs232 9p d - sub fem ale rs232 9p d - sub male 9 rx 3 t x d 6 tx 2 r x d 5 gnd 5 gnd 7 rts circ uit 8 cts www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 521 the following represents the view of hmi & plc. saia pcd1 port #1 (port #0) terminal emt3000 series com1 rs485 2 w 9p d - sub m ale com 3 rs485 2 w 9p d - sub m ale saia pcd1 port #1 (port #0) terminal 1 rx - 6 data - 11 (29) 2 rx+ 9 data+ 12 (28) 5 gnd 5 gnd mt6000 /8000 series except mt6050i/mt8050i com1 rs485 2 w 9p d - sub m ale com 3 rs485 2 w 9p d - sub m ale saia pcd1 port #1 (port #0) terminal 1 rx - 6 data - 11 (29) 2 rx+ 9 data+ 12 (28) 5 gnd 5 gnd mt6050i/mt8050i com1 rs485 2 w 9p d - sub fem ale com 3 rs485 2 w 9p d - sub fem ale saia pcd1 port #1 (port #0) terminal 1 rx - 7 data - 11 (29) 2 rx+ 8 data+ 12 (28) 5 gnd 5 gnd driver version : version date description v1. 4 0 jun/21 /2012 dbn address types are add ed. www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 522 saia s - bus ( ethernet) supported s eries : saia pcd series ethernet - tcp/ip . website : http://www.saia - burgess.com/ hmi setting: parameters r ecommend ed option s notes plc type saia s - bus (ethernet) plc i/f ethernet port n o. 5050 plc s t a . n o. 0 plc setting : www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 523 device address: bit/word device t ype format range memo b flag dddd 0 ~ 8191 b output dddd 0 ~ 1023 b input dddd 0 ~ 1023 b reg_bit dddddd 0 ~ 1638331 d d: bit no. (00 ~ 31) d w register ddddd 0 ~ 16383 d w counter dddd 0 ~ 1599 d w timer dddd 0 ~ 1599 d w reg_float ddddd 0 ~ 16383 support single float point dw dbn ddddddddd 0 ~ 536016383 www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 524 wiring d iagram: direct connect (crossover cable): hmi rj45 m ale wire color plc rj45 m ale 1 tx+ white/orange 3 rx+ 2 tx - orange 6 rx - 3 rx+ white/green 1 tx+ 4 bd4+ blue 4 bd4+ 5 bd4 - white/blue 5 bd4 - 6 rx - green 2 tx - 7 bd3+ white/brown 7 bd3+ 8 bd3 - brown 8 bd3 - through a hub: hmi rj45 m ale wire co lor plc rj45 m ale 1 tx+ white/orange 1 tx+ 2 tx - orange 2 tx - 3 rx+ white/green 3 rx+ 4 bd4+ blue 4 bd4+ 5 bd4 - white/blue 5 bd4 - 6 rx - green 6 rx - 7 bd3+ white/brown 7 bd3+ 8 bd3 - brown 8 bd3 - driver version : version date description v1.40 jun/21/2012 dbn address types are added. www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 525 samsung spc - 10 supp orted s eries: samsung spc - 10 website: http://www.samsungelectronics.com/factory_automation/controller/plc/ hmi setting: parameters recommend ed option s notes plc type samsung spc - 10 plc i/f rs485 2w baud rate 9600 data b its none parity 8 stop b its 1 plc s t a . n o. 192 device a ddress: bit/word device t ype format range memo b r dddddd 0 ~ 9 99915 b k dddddd 0 ~ 999915 b m dddddd 0 ~ 999915 b f dddddd 0 ~ 999915 w w dddd 0 ~ 9999 www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 526 wiring d iagram: the following represents the view of hmi & plc. e mt 3 000 series com1 rs485 2 w 9p d - sub m ale com 3 rs485 2 w 9p d - sub m ale rs485 2w 8p mini - d in male 1 rx - 6 data - 6 tr - 2 rx+ 9 data+ 7 tr+ 5 gnd 5 gnd 5 gnd mt6000 /8000 series except mt6050i/mt8050i com1 rs485 2 w 9p d - sub m ale com 3 rs485 2 w 9p d - sub m ale rs485 2w 8p mini - din male 1 rx - 6 data - 6 tr - 2 rx+ 9 data+ 7 tr+ 5 gnd 5 gnd 5 gnd mt6050i/mt8050i com1 rs485 2 w 9p d - sub fem ale com 3 rs485 2 w 9p d - sub fem ale rs485 2w 8p mini - din male 1 rx - 7 data - 6 tr - 2 rx+ 8 data+ 7 tr+ 5 gnd 5 gnd 5 gnd driver version: version date description v1.00 may/19/2 009 www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 527 scene6 controller hmi setting: parameters recommend ed option s notes plc type scene6 controller plc i/f rs232 baud rate 9600 data bits 8 parity none stop bits 2 plc s t a . n o. 0 device a ddress: bit/word device t ype format range m emo w word dd 0 ~ 99 wiring d iagram: the following represents the view of hmi & plc. e mt 3 000 series com1 rs232 9p d - sub fem ale com 3 rs232 9p d - sub fem ale rs232 terminal 2 rx 8 rx t d 3 tx 7 tx r d 5 gnd 5 gnd gnd www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 528 mt6000 /8000 series exce pt mt6050i/mt8050i com1 rs232 9p d - sub fem ale com2 rs232 9p d - sub fem ale com3 rs232 9p d - sub m ale rs232 terminal 2 rx 6 rx 8 rx t d 3 tx 4 tx 7 tx r d 5 gnd 5 gnd 5 gnd gnd mt6050i/mt8050i com1 rs232 9p d - sub fem ale rs232 terminal 9 rx t d 6 tx r d 5 gnd gnd driver version : version date description v1. 0 0 aug /2 4/2009 www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 529 schleicher xc s 20c supported s eries: schleicher xcx - systems ethernet port. schleicher xcs series, 20c model . website: http://www.schleicher - electronic.com hmi setting: parameters recommend ed option s notes plc type schleicher xcs 20c plc i/f rs232 baud rate 38400 data b its 8 parity n stop b its 1 plc s t a . n o. 0 device a ddress: bit/word de vice t ype format range memo b ix dddddo 0 ~ 655357 input %ix b qx dddddo 0 ~ 655357 output %qx b mx dddddo 0 ~ 655357 %mx w iw ddddd 0 ~ 65535 %iw w qw ddddd 0 ~ 65535 %qw w mw ddddd 0 ~ 65535 %mw dw id ddddd 0 ~ 65535 %id dw qd ddddd 0 ~ 65535 %qd dw md ddddd 0 ~ 65535 %wd ? w ord address must be even. www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 530 wiring d iagram: the following represents the view of hmi & plc. e mt 3 000 series com1 rs232 9p d - sub fem ale com 3 rs232 9p d - sub fem ale schleicher xcs20 rs232 9p d - sub male 2 rx 8 rx 3 t d 3 tx 7 tx 2 r d 5 gnd 5 gnd 5 gnd mt6000 /8000 series except mt6050i/mt8050i com1 rs232 9p d - sub fem ale com2 rs232 9p d - sub fem ale com3 rs232 9p d - sub m ale schleicher xcs20 rs232 9p d - sub male 2 rx 6 rx 8 rx 3 t d 3 tx 4 tx 7 tx 2 r d 5 gnd 5 gnd 5 gnd 5 gnd www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 531 mt6050i/mt8050i com1 rs232 9p d - sub fem ale schleicher xcs20 rs232 9p d - sub male 9 rx 3 t d 6 tx 2 r d 5 gnd 5 gnd driver version : version date description v1. 10 feb / 26 /20 10 www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 532 schleicher xcx 300 website: http://www.schleicher - electronic.com hmi setting: parameters recommend ed option s notes plc type schleicher xcx 300 plc i/f ethernet rs232, rs422, ethernet port n o. 20547 plc s t a . n o. 2 plc setting: a variable must be created for hmi access. device a ddress: bit/word device t ype format range memo b ix dddddo 0 ~ 655357 input %ix b qx dddddo 0 ~ 655357 output %qx b mx dddddo 0 ~ 655357 %mx w iw ddddd 0 ~ 65535 %iw w qw ddddd 0 ~ 65535 %qw w mw ddddd 0 ~ 65535 %mw dw id ddddd 0 ~ 65535 %id dw qd ddddd 0 ~ 65535 %qd dw md ddddd 0 ~ 65535 %wd ? w ord address must be even. www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 533 wiring d iagram: direct connect (crossover cable): hmi rj45 m ale wire color plc rj45 m ale 1 tx+ white/orange 3 rx+ 2 tx - or ange 6 rx - 3 rx+ white/green 1 tx+ 4 bd4+ blue 4 bd4+ 5 bd4 - white/blue 5 bd4 - 6 rx - green 2 tx - 7 bd3+ white/brown 7 bd3+ 8 bd3 - brown 8 bd3 - through a hub: hmi rj45 m ale wire color plc rj45 m ale 1 tx+ white/orange 1 tx+ 2 tx - orange 2 tx - 3 rx+ white/green 3 rx+ 4 bd4+ blue 4 bd4+ 5 bd4 - white/blue 5 bd4 - 6 rx - green 6 rx - 7 bd3+ white/brown 7 bd3+ 8 bd3 - brown 8 bd3 - www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 534 the following represents the view of hmi & plc. schleicher xcx300 rs232 port emt3000 series com1 rs232 9p d - s ub fem ale com 3 rs232 9p d - sub fem ale rs232 9p d - sub female 2 rx 8 rx 3 t x d 3 tx 7 tx 2 r x d 5 gnd 5 gnd 5 gnd mt6000 /8000 series except mt6050i/mt8050i com1 rs232 9p d - sub fem ale com2 rs232 9p d - sub fem ale com3 rs232 9p d - sub m ale rs232 9 p d - sub female 2 rx 6 rx 8 rx 3 t x d 3 tx 4 tx 7 tx 2 r x d 5 gnd 5 gnd 5 gnd 5 gnd mt6050i/mt8050i com1 rs232 9p d - sub fem ale rs232 9p d - sub female 9 rx 3 t x d 6 tx 2 r x d 5 gnd 5 gnd www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 535 the following represents the view of hmi & plc. schleicher xcx300 rs 485 4w terminal e mt 3 000 series com1 rs485 4 w 9p d - sub m ale rs485 4w terminal 1 rx - t x - 2 r x + tx+ 3 tx - rx - 4 tx+ rx+ 5 gnd gnd mt6000 /8000 series except mt6050i/mt8050i com1 rs485 4 w 9p d - sub m a le rs485 4w terminal 1 rx - t x - 2 r x + tx+ 3 tx - rx - 4 tx+ rx+ 5 gnd gnd mt6050i/mt8050i com1 rs485 4 w 9p d - sub fem ale rs485 4w terminal 1 rx - t x - 2 r x + tx+ 3 tx - rx - 4 tx+ rx+ 5 gnd gnd www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 536 driver ve rsion : version date description v1.00 nov/30/2009 driver released . v1.10 ju n / 28 /2010 support rs232, rs422 interface connection . www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 537 schneider modbus rtu supported s eries : schneider modbus rtu controller website: http://www.schleicher - electronic.com hmi setting: parameters recommend ed option s notes plc type schneider modbus rtu plc i/f rs 485 rs 232/rs485 baud rate 9600 9600 ~ 115200 data b its 8 7, 8 parity even even, odd, none stop b its 1 1 ,2 plc s t a . n o. 1 0 - 255 online s imulator yes broadcast command yes extend address mode yes plc setting: communication mode modbus rtu protocol device a ddress: bit/word device t ype format range memo b %m ddddd 0 ~ 65535 output bit b 1x ddddd 0 ~ 6 5535 input bit (read only) b 3x_bit ddddddd 0 ~ 65535 15 input register bit (read only) b 4x_bit ddddddd 0 ~ 65535 15 output register bit b 0x _multi_coils ddddd 0 ~ 65535 write m ultiple c oils w 3x ddddd 0 ~ 65535 input register (read only) w %mw ddddd 0 ~ 65535 output register dw 5x ddddd 0 ~ 65535 4x double word swap w 6x ddddd 0 ~ 65535 4x single word write www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 538 wiring d iagram: the following represents the view of hmi & plc. rs232 e mt 3 000 series com1 rs232 9p d - sub fem ale com 3 rs232 9p d - sub fem ale r s232 9p d - sub female 2 rx 8 rx 2 b - 3 tx 7 tx 1 a+ 5 gnd 5 gnd 5 dtp mt6000 /8000 series except mt6050i/mt8050i com1 rs232 9p d - sub fem ale com2 rs232 9p d - sub fem ale com3 rs232 9p d - sub m ale rs232 9p d - sub female 2 rx 6 rx 8 rx 3 t x 3 tx 4 tx 7 tx 2 r x 5 gnd 5 gnd 5 gnd 5 gnd mt6050i/mt8050i com1 rs232 9p d - sub fem ale rs232 9p d - sub female 9 rx 3 t x 6 tx 2 r x 5 gnd 5 gnd www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 539 the following represents the view of hmi & plc. 9p d - sub to 8 p mini - din : rs485 2w e mt 3 000 series com1 rs485 2 w 9p d - sub m ale com 3 rs485 2 w 9p d - sub m ale rs 485 2w 8p mini - din male 1 rx - 6 data - 2 b - 2 rx+ 9 data+ 1 a+ 5 gnd 5 gnd 5 dtp circuit 7 gnd mt6000 /8000 series except mt6050i/mt8050i com1 rs485 2 w 9p d - sub m ale com 3 rs 485 2 w 9p d - sub m ale rs 485 2w 8p mini - din male 1 rx - 6 data - 2 b - 2 rx+ 9 data+ 1 a+ 5 gnd 5 gnd 5 dtp circuit 7 gnd mt6050i/mt8050i com1 rs485 2 w 9p d - sub fem ale com 3 rs485 2 w 9p d - sub fem ale rs 485 2w 8p mini - din male 1 rx - 7 data - 2 b - 2 rx+ 8 data+ 1 a+ 5 gnd 5 gnd 5 dtp circuit 7 gnd www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 540 the following represents the view of hmi & plc. 9p d - sub to terminal : rs485 2w e mt 3 000 series com1 rs485 2 w 9p d - sub m ale com 3 rs485 2 w 9p d - sub m ale rs 485 2w 3p terminal 1 rx - 6 d ata - b - 2 rx+ 9 data+ a+ 5 gnd 5 gnd gnd mt6000 /8000 series except mt6050i/mt8050i com1 rs485 2 w 9p d - sub m ale com 3 rs485 2 w 9p d - sub m ale rs 485 2w 3p terminal 1 rx - 6 data - b - 2 rx+ 9 data+ a+ 5 gnd 5 gnd gnd mt6050i/mt8050i com1 rs485 2 w 9p d - sub fem ale com 3 rs485 2 w 9p d - sub fem ale rs 485 2w 3p terminal 1 rx - 7 data - b - 2 rx+ 8 data+ a+ 5 gnd 5 gnd gnd driver version : version date description v1.30 aug/26/2009 www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 541 schneider modbus tcp/ip supported s eries : sch neider modbus rtu tcp/ip device . website: http://www.schleicher - electronic.com hmi setting: parameters recommend ed option s notes plc type schneider modbus tcp/ip plc i /f ethernet p ort n o. 502 plc s t a . n o. 1 0~255 device a ddress: bit/word device t ype format range memo b %m ddddd 0 ~ 65535 input bit b 1x ddddd 0 ~ 65535 output bit b 3x_ b it ddddddd 0 ~ 65535 15 input register bit (read only) b 4x_ b it ddddddd 0 ~ 65535 15 output register bit b 6x_ b it ddddddd 0 ~ 65535 15 output register bit b 0x_multi_coils ddddd 0 ~ 65535 write m ultiple c oils w 3x ddddd 0 ~ 65535 input register w %mw ddddd 0 ~ 65535 output register dw 5x ddddd 0 ~ 65535 4x double word swap w 6x ddddd 0 ~ 65535 4x single word write www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 542 wiring d iagram: direct connect (crossover cable): hmi rj45 m ale wire color plc rj45 m ale 1 tx+ white/orange 3 rx+ 2 tx - orange 6 rx - 3 rx+ white/green 1 tx+ 4 bd4+ blue 4 bd4+ 5 bd4 - white/blue 5 bd4 - 6 rx - green 2 tx - 7 bd3+ white/bro wn 7 bd3+ 8 bd3 - brown 8 bd3 - through a hub: hmi rj45 m ale wire color plc rj45 m ale 1 tx+ white/orange 1 tx+ 2 tx - orange 2 tx - 3 rx+ white/green 3 rx+ 4 bd4+ blue 4 bd4+ 5 bd4 - white/blue 5 bd4 - 6 rx - green 6 rx - 7 bd3+ white/brown 7 bd3+ 8 bd3 - brown 8 bd3 - driver version : version date description v1.40 aug/27/2009 www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 543 schneider unitelway supported s eries: modicon tsx micro&nano&neza series plc . website: http://www. modicon. com hmi setting: p arameters recommend ed option s notes plc type schneider unitelway plc i/f rs485 2w rs232/rs485 baud rate 19200 9600~ 115200 data b its 8 7, 8 must set to 8 for this protocol parity odd even, odd, none stop b its 1 1 , 2 hmi s t a . n o. 5 1 - 8 plc s t a . n o. 0 0 - 3 online s imulator yes extend address mode yes broadcast command no plc setting: communication mode unitelway protocol, set plc as master device a ddress: bit/word device t ype format range memo b s ddddd 0 ~ 32767 internal relay b m dddd d 0 ~ 32767 auxiliary relay b mw.b ddddddd 0 ~ 3276715 data register bit w mw ddddd 0 ~ 32767 data register www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 544 wiring d iagram: the following represents the view of hmi & plc. tsx37 - xx/tsx07 - xx cpu : 9p d - sub to 9p d - sub e mt 3 000 series com1 rs485 2 w 9p d - sub m ale com 3 rs485 2 w 9p d - sub m ale rs 485 2w 8 p mini - din male 1 rx - 6 data - 2 d - 2 rx+ 9 data+ 1 d+ 5 gnd 5 gnd 7 gnd mt6000 /8000 series except mt6050i/mt8050i com1 rs485 2 w 9p d - sub m ale com 3 rs485 2 w 9p d - sub m ale rs 485 2w 8 p mini - din m ale 1 rx - 6 data - 2 d - 2 rx+ 9 data+ 1 d+ 5 gnd 5 gnd 7 gnd mt6050i/mt8050i com1 rs485 2 w 9p d - sub fem ale com 3 rs485 2 w 9p d - sub fem ale rs 485 2w 8 p mini - din male 1 rx - 7 data - 2 d - 2 rx+ 8 data+ 1 d+ 5 gnd 5 gnd 7 gnd driver version : version date description v1.30 sep/24/2009 www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 545 s ew movilink supported s eries: sew eurodrive series, model movitrac - 07 inverter , movitracb . website: http://sg.sew - eurodrive.com/ hmi setting: parameters recommend ed option s notes plc type sew movilink plc i/f rs 485 2w baud rate 9600 data bit s 8 parity even stop bit s 1 plc s t a . n o. 0 0~255 device a ddress: bit/word device t ype format range memo b index_bit dddddddddd 0 ~ 2552500031 w index dddddddd 0 ~ 25525000 the movitrac - 07 doesnt support sub index other series may support , please input 000. when input d and d , the correct format sub index 15, index 8359, format is 01508359 . wiring d iagram: the following represents the view of hmi & plc. e mt 3 000 series com1 rs485 2 w 9p d - sub m ale com 3 rs485 2 w 9p d - sub m ale movitrac - 07 rs485 2w 1 rx - 6 data - d - (green) 2 rx+ 9 data+ d+ (red) 5 gnd 5 gnd www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 546 mt6000 /8000 series except mt6050i/mt8050i com1 rs485 2 w 9p d - sub m ale co m 3 rs485 2 w 9p d - sub m ale movitrac - 07 rs485 2w 1 rx - 6 data - d - (green) 2 rx+ 9 data+ d+ (red) 5 gnd 5 gnd mt6050i/mt8050i com1 rs485 2 w 9p d - sub fem ale com 3 rs485 2 w 9p d - sub fem ale movitrac - 07 rs485 2w 1 rx - 7 data - d - (green) 2 rx+ 8 data+ d+ (red) 5 gnd 5 gnd driver version : version date description v1.31 jun/25/2010 www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 547 sew movitrac lte w ebsite : http://www.seweurodrive.com/index.php hmi setting: parameters rec ommend ed option s notes plc type sew movitrac lte plc i/f rs - 485 2w baud rate 115200 data b its 8 parity none stop bits 1 plc s t a . n o. 1 online s imulator yes extend address mode no device a ddress: bit/word device t ype format range mem o w p - 1 d 0 ~ 1 max. speed limit w p - 2 d 0 ~ 1 min. speed limit w p - 3 d 0 ~ 1 acceleration ramp time w p - 4 d 0 ~ 1 deceleration ramp time w p - 5 d 0 ~ 1 stop mode select w p - 6 d 0 ~ 1 energy optimizer w p - 7 d 0 ~ 1 m otor rated voltage w p - 8 d 0 ~ 1 motor rated current w p - 9 d 0 ~ 1 motor rated frequency w p - 10 d 0 ~ 1 motor rated speed w p - 11 d 0 ~ 1 voltage boost w p - 12 d 0 ~ 1 terminal / keypad control w p - 13 d 0 ~ 1 trip log w p - 14 d 0 ~ 1 extended menu access code w p - 15 d 0 ~ 1 digital in put function set w p - 16 d 0 ~ 1 analog input v / ma w p - 17 d 0 ~ 1 output switching frequency www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 548 bit/word device t ype format range mem o w p - 18 d 0 ~ 1 user relay output select w p - 19 d 0 ~ 1 user relay output limit w p - 20 d 0 ~ 1 p reset speed 1 w p - 21 d 0 ~ 1 p reset speed 2 w p - 22 d 0 ~ 1 p reset speed 3 w p - 23 d 0 ~ 1 p reset speed 4 w p - 24 d 0 ~ 1 deceleration ramp time 2 w p - 25 d 0 ~ 1 analog output function select w p - 26 d 0 ~ 1 skip frequency hysteris band w p - 27 d 0 ~ 1 skip frequency w p - 28 d 0 ~ 1 v/f characteristic adjustment vo ltage w p - 29 d 0 ~ 1 v/f characteristic adjustment frequency w p - 30 d 0 ~ 1 terminal mode restart function w p - 31 d 0 ~ 1 keypad mode restart function w p - 32 d 0 ~ 1 dc injection enable / duration w p - 33 d 0 ~ 1 spin start w p - 34 d 0 ~ 1 brake choppe r enable w p - 35 d 0 ~ 1 analog input scaling factor w p - 36 d 0 ~ 1 c omms address; sbus enable/baudrate select; trip enable / delay w p - 37 d 0 ~ 1 access code definition w p - 38 d 0 ~ 1 parameter access lock w p - 39 d 0 ~ 1 analog input off - set w p - 40 d 0 ~ 1 display speed scaling factor w p - 00 - 01 d 0 ~ 1 analog input 1 value w p - 00 - 02 d 0 ~ 1 analog input 2 value w p - 00 - 03 d 0 ~ 1 speed reference input w p - 00 - 04 d 0 ~ 1 digital input status w p - 00 - 05 d 0 ~ 1 reserved w p - 00 - 06 d 0 ~ 1 reserved w p - 00 - 07 d 0 ~ 1 applied motor voltage w p - 00 - 08 d 0 ~ 1 dc bus voltage log w p - 00 - 09 d 0 ~ 1 heatsink temperature w p - 00 - 10 d 0 ~ 1 hours run meter w p - 00 - 11 d 0 ~ 1 run time since last trip (1) w p - 00 - 12 d 0 ~ 1 run time since last trip (2) w p - 00 - 1 3 d 0 ~ 1 run time since last disable www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 549 bit/word device t ype format range mem o w p - 00 - 14 d 0 ~ 1 reserved w p - 00 - 15 d 0 ~ 1 dc bus voltage log w p - 00 - 16 d 0 ~ 1 thermistor temperature log w p - 00 - 17 d 0 ~ 1 motor current w p - 00 - 18 d 0 ~ 1 software id,io and motor control w p - 00 - 19 d 0 ~ 1 dr ive serial number w p - 00 - 20 d 0 ~ 1 drive identifier p - 00 - 01 ~ p - 00 - 20 read only. wiring d iagram: the following represents the view of hmi & plc. e mt 3 000 series com1 rs485 2 w 9p d - sub m ale com 3 rs485 2 w 9p d - sub m ale plc rs485 2w 8p rj45 male 1 rx - 6 data - 4 - 2 rx+ 9 data+ 5 + 5 gnd 5 gnd mt6000 /8000 series except mt6050i/mt8050i com1 rs485 2 w 9p d - sub m ale com 3 rs485 2 w 9p d - sub m ale plc rs485 2w 8p rj45 male 1 rx - 6 data - 4 - 2 rx+ 9 data+ 5 + 5 gnd 5 gnd www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 550 mt6050i/mt 8050i com1 rs485 2 w 9p d - sub fem ale com 3 rs485 2 w 9p d - sub fem ale plc rs485 2w 8p rj45 male 1 rx - 7 data - 4 - 2 rx+ 8 data+ 5 + 5 gnd 5 gnd driver version : version date description v1. 0 0 may / 19 /20 11 driver released . www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 551 shimaden mr13/fp 93 supported s eries: mr13, fp93 devices website: http://www.shimaden.co.jp hmi s etting : note address 018c is a communication control register, only when it is set to 1 can this register be allowed to write to other registers. parameters recommended options notes plc t ype shimaden mr13 /fp93 plc i/f rs485 baud r ate 9600 1200 - 19200 data b its 7 7 or 8 parity e none/even stop b its 1 1 plc sta. n o. 1 1~255 start character mode select 3 for fp93, select 0,1 bcc operation method select 3 addition +2 www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 552 device address : bit/word device type format range memo w channel 1 hhhh 0 ~ ffff read/write 1st channel register w channel 2 hhhh 0 ~ ffff read/write 2nd channel register w channel 3 hhhh 0 ~ ffff read/write 3rd channel register wiring diagram: the following represents the view of hmi & plc. e mt 3 000 series com1 rs485 2 w 9p d - sub m ale com 3 rs485 2 w 9p d - sub m ale mr13/fp93 rs485 2w terminal 1 rx - 6 data - 25 - 2 rx+ 9 data+ 24 + 5 gnd 5 gnd 23 gnd mt6000 /8000 series except mt6050i/mt8050i com1 rs485 2 w 9p d - sub m ale com 3 rs485 2 w 9p d - sub m ale mr13/fp93 rs485 2w terminal 1 rx - 6 data - 25 - 2 rx+ 9 data+ 24 + 5 gnd 5 gnd 23 gnd mt6050i/mt8050i com1 rs485 2 w 9p d - sub fem ale com 3 rs485 2 w 9p d - sub fem ale mr13/fp93 rs485 2w terminal 1 rx - 7 data - 25 - 2 rx+ 8 data+ 24 + 5 gnd 5 gnd 23 gnd www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 553 mr13 communication parameter settings data address (hex) parameter details of parameter r /w 0100 pv value within measuring range r 0101 e_sv execution sv value within setting range r 0102 out control output value within range 0 . 0 r 0103 reserved 0104 action flag r 0105 event output flag r 0106 reserved 0107 reserved 0108 rem value within setting range r 0109 reserved 010a reserved 010b di input state flag r data address (hex) parameter details of parameter r /w 0111 range ref er to the measuring range code list. r 0112 reserved 0113 dp decimal point position of decimal point r 0114 pv sc_l lower limit for linear imput : - 1999 for thermocouple, and rtd input: measurin g range to be displayed. r 0115 pv sc_h higher limit r data address (hex) parameter details of parameter r/w 0120 e _ prg program action flag r 0121 reserved www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 554 0122 reserved 0123 e _ prt the number of execution patterns when program is reset, val ue=7ffeh r 0124 e _ stp execution step number when program is reset, value=7ffeh r 0125 e _ tim remaining time of execution step when program is reset, value=7ffeh r 0126 e _ pid execution pid number when program is reset, va lue=7ffeh r data address (hex) parameter details of parameter r/w 0184 at auto tuning 0: no execution 1: execution w 018c operation 0: local 1: com w 0190 prog run/rst program run / reset 0 w 0191 prog hld program hold 0 w 0300 sv local sv value, within set value limiter r / w data address (hex) parameter details of parameter r/w 030a sv limt _l lower limit within measuring range, o n condition that sv limt_l plc connection guide 555 0314 rem sc _ l within measuring range on condition that rem sc_l rem sc_h r/w 0315 rem sc_ h 0316 rem bias range: - 1999 5000 unit r/w 0317 rem filt range: 0 100 seconds r/w 031a rem - ch remote channel assignment 0 r/w data address (hex) parameter details of parameter r/w 0320 sv follow sw ch2 & ch3 sv follow setting flag 1: follow 0:n o r/w 0321 sv follow follow type deviation sv set value: 1999 r/w 0400 fix p control output proportional baud range: 0.0 r/w 0401 fix i control output integral time range: 0 r/w 0402 fix d control output derivative time range 0 r/w 0 403 fix mr manual reset range: - 50.0 r/w 0404 fix df hysteresis range: 1 r/w 0405 fix out limt _l control output lower limit output limiter range: 0.0 0406 fix out limt_h control output higher limit output limiter range: 0.1 r/w 0407 fix sf control output target value function range: off 0408 prog p1 prog mode pb1 range: 0.0 r/w 0409 prog i1 prog mode it1 range: 0 r/w 040a prog d1 prog mode dt1 range: 0 r/w www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 556 040b prog mr1 prog mode mr1 range: - 50.0 50.0 % r/w 040c prog df1 prog mode df1 range: 1 999 unit r/w 040d prog o_lmt_l1 prog mode lower limit side output limiter 1 range: 0.0 99.9% r/w 040e prog o_lmt_h1 prog mode higher limit side output limiter 1 range: 0.1 100.0% r/w 040f prog sf1 prog mode target value function 1 range: off,0.01 1.00 r/w 0410 prog p2 prog mode pb2 range: 0.0 999.9% (0.0:off) r/w 0411 prog i2 prog mode it2 range: 0 6000 seconds (0.0:off) r/w 041 2 prog d2 prog mode dt2 range: 0 3600 seconds (0.0:off) r/w 0413 prog mr2 prog mode mr2 range: - 50.0 50.0 % r/w 0414 prog df2 prog mode df2 range: 1 999 unit r/w 0415 prog o_lmt_l2 prog mode lower limit side output limiter 2 range: 0.0 99.9% r/w 04 16 prog o_lmt_h2 prog mode higher limit side output limiter 2 range: 0.1 100.0% r/w 0417 prog sf2 prog mode target value function 2 range: off,0.01 1.00 r/w 0418 prog p3 prog mode pb3 range: 0.0 999.9% (0.0:off) r/w 0419 prog i3 prog mode it3 range : 0 6000 seconds (0.0:off) r/w 041a prog d3 prog mode dt3 range: 0 3600 seconds (0.0:off) r/w 041b prog mr3 prog mode mr3 range: - 50.0 50.0 % r/w 041c prog df3 prog mode df3 range: 1 999 unit r/w 041d prog o_lmt_l3 prog mode lower limit side out put r/w www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 557 limiter 3 range: 0.0 99.9% 041e prog o_lmt_h3 prog mode higher limit side output limiter 3 range: 0.1 100.0% r/w 041f prog sf3 prog mode target value function 3 range: off,0.01 1.00 r/w 0500 ev1 _mode 0: not assigned 1: higher limit deviation value 2 :lower limit deviation value 3: out of range between higher & lower limits 4: within range between higher & lower limits 5: higher limit absolute value 6: lower limit absolute value 7: scaleover 8: program run 9: program end 10: program step only when subaddress =ev1_ch. r/w 0501 ev1 set point 1. higher limit deviation value alarm : 0 2. lower limit deviation value alarm : 0 0502 ev1 diffrnt alarm hysteresis 1 only when subaddress =ev1_ch . r/w 0503 ev1 inhibit alarm stand by 1 only when subaddress =ev1_ch . r/w www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 558 0504 ev1 dela y alarm delay time 0 9999 seconds only when subaddress =ev1_ch . r/w 0506 ev1 _ch channel number setting 1:ch1, 2:ch2, 3:ch3 r/w 0510 ev2 _mode 0: not assigned 1: higher limit deviation value 2 :lower limit deviation value 3: out of range between higher & lower limits 4: within range between higher & lower limits 5: higher limit absolute value 6: lower limit absolute value 7: scaleover 8: program run 9: program end 10: program step only when subaddress =ev 2 _ch. r/w 0511 ev2 set poi nt 1. higher limit deviation value alarm : 0 2. lower limit deviation value alarm : 0 0512 ev2 diffrnt alarm hysteresis 1 only when subaddress =ev 2 _ch . r/w 0513 ev2 inhibit alarm stand by 1 only when subaddress =ev 2 _ch . r/w 0514 ev2 delay alarm delay time 0 r/w www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 559 only when subaddress =ev 2 _ch . 0516 ev2 _ch channel number setting 1:ch1, 2:ch2, 3:ch3 r/w 0520 ev3 _mode 0: not assigned 1: higher limit deviation value 2 :lower limit deviation value 3: out of range between higher & l ower limits 4: within range between higher & lower limits 5: higher limit absolute value 6: lower limit absolute value 7: scaleover 8: program run 9: program end 10: program step only when subaddress =ev 3 _ch. r/w 0521 ev3 set point 1. higher limit deviation value alarm : 0 2. lower limit deviation value alarm : 0 r/w 0522 ev3 diffrnt alarm hysteresis 1 only when subaddress =ev 3 _ch . r/w 0523 ev3 inhibit alarm stand by 1 only when subaddress =ev 3 _ch . r/w 0524 ev3 delay alarm delay time 0 only when subaddress =ev 3 _ch . r/w www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 560 0526 ev3 _ch channel number setting 1:ch1, 2:ch2, 3:ch3 r/w 0580 di di setting flag 0:non 1:flw 2:run 3:hld 4:adv r/w 05b0 mem 1:eep program memory 0:ram random memory r/w 0 600 out actn output characteristic setting flag 0:rev act. 1:dir act r/w 0601 out cyc control output cycle ( unit :0.5 seconds ) range: 0.5 r/w 0602 reserved 0603 softsw soft start setting flag 0:off 1:on 0610 at point at pointer range: 0 r/w 0611 key lock 0:off 1:lock1 2:lock2 3:lock3 r/w when out_cyc is written, writing data is adjusted to 0.5 sec as one unit. the write command lock by keylock is the same as the screen lock. (refer t o the manual of the instrument.) if there is a change in ev1 _ch,ev2_ch,ev3_ch, the related parameters are initialized. 0701 pv b ias pv bias range: - 1999 r/w 0702 pv filt pv filter range: 0 r/w 0710 pflw setting of ch2, ch3 p v input follow 0:off 1:on r/w 0711 ch_p selection of ch2, ch3 pv display or not 0 - 0 window 0: without 1: with r/w www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 561 0800 fp_mod selection between fix and prog 0:fix 1:prog ( writing possible only in ch1) r/w 0801 pv_st setting of pv start 0:off 1:o n ( writing possible only in ch1) r/w 0882 stp the number of steps 1 r/w 0883 rpt the number of execution repetitions 1 r/w 0884 st_sv start sv ( writing possible only in ch1) r/w f o r ch1, pflw (window 1~30), ch_p (window 1 - 29 display - - - - .the read value is: 7ffeh , to a write command, error 0bh is returned. 08a0 s tep1 sv s tep no. 1 sv value ( writing possible only in ch1) r/w 08a1 step1 time step no. 1 step time ( writing possible only in ch1) r/w 08a2 step1 pid no step no. 1 pid no. r/w 08a3 reserved 08a4 s tep2 sv s tep no. 2 sv value ( writing possible only in ch1) r/w 08a5 step2 time step no. 2 step time ( writing possible only in ch1) r/w 08a6 step2 pid no step no. 2 pid no. r/w 08a7 reserved 08a8 s tep3 sv s t ep no. 3 sv value ( writing possible only in ch1) r/w 08a9 step3 time step no. 3 step time ( writing possible only in ch1) r/w 08aa step3 pid no step no. 3 pid no. r/w 08ab reserved 08ac s tep4 sv s tep no. 4 sv value ( writing possible only in ch1 ) r/w 08ad step4 time step no. 4 step time r/w www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 562 ( writing possible only in ch1) 08ae step4 pid no step no. 4 pid no. r/w 08af reserved 08b0 s tep5 sv s tep no. 5 sv value ( writing possible only in ch1) r/w 08b1 step5 time step no. 5 step time ( writing possible only in ch1) r/w 08b2 step5 pid no step no. 5 pid no. r/w 08b3 reserved 08b4 s tep6 sv s tep no. 6 sv value ( writing possible only in ch1) r/w 08b5 step6 time step no. 6 step time ( writing possible only in ch1) r/w 08b6 st ep6 pid no step no. 6 pid no. r/w 08b7 reserved 08b8 s tep7 sv s tep no. 7 sv value ( writing possible only in ch1) r/w 08b9 step7 time step no. 7 step time ( writing possible only in ch1) r/w 08ba step7 pid no step no. 7 pid no. r/w 08bb reserve d 08bc s tep8 sv s tep no. 8 sv value ( writing possible only in ch1) r/w 08bd step8 time step no. 8 step time ( writing possible only in ch1) r/w 08be step8 pid no step no. 8 pid no. r/w 08bf reserved 08c0 s tep9 sv s tep no. 9 sv value ( writing possible only in ch1) r/w 08c1 step9 time step no. 9 step time ( writing possible only in ch1) r/w 08c2 step9 pid no step no. 9 pid no. r/w driver version : version date description v1. 2 0 apr / 08 /201 1 www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 563 shj - a hmi setting: parameters recommend e d option s notes plc type shj - a plc i/f rs485 2w baud rate 9600 data b its 8 parity none stop b its 1 plc s t a . n o. 0 device a ddress: bit/word device t ype format range memo w word dd 0 ~ 89 wiring d iagram: the following represents the view of hmi & plc. e mt 3 000 series com1 rs485 2 w 9p d - sub m ale com 3 rs485 2 w 9p d - sub m ale rs 485 terminal 1 rx - 6 data - d - 2 rx+ 9 data+ d+ 5 gnd 5 gnd www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 564 mt6000 /8000 series except mt6050i/mt8050i com1 rs485 2 w 9p d - sub m ale com 3 rs485 2 w 9 p d - sub m ale rs 485 terminal 1 rx - 6 data - d - 2 rx+ 9 data+ d+ 5 gnd 5 gnd mt6050i/mt8050i com1 rs485 2 w 9p d - sub fem ale com 3 rs485 2 w 9p d - sub fem ale rs 485 terminal 1 rx - 7 data - d - 2 rx+ 8 data+ d+ 5 gnd 5 gnd driver ver sion: version date description v1.00 oct/18/2011 driver released . www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 565 sick flexi soft hmi setting: parameters recommend ed option s notes plc type sick flexi soft plc i/f rs232 baud rate 115200 9600,19200,3840 0,57600,115200 data b its 8 parity none stop b its 1 plc s t a . n o. 0 device a ddress: bit/word device t ype format range memo b i dd o 0 ~ 9 67 input b q dd o 0 ~ 487 output b logic result dd o 0 ~ 327 logic result b rs - 232 dd o 0 ~ 327 rs - 232 wiring d iagram: the following represents the view of hmi & plc. e mt 3 000 series com1 rs232 9p d - sub fem ale com 3 rs232 9p d - sub fem ale flexi soft cpu0 port0 4 p m ini - din male 2 rx 8 rx 3 t x 3 tx 7 tx 2 r x 5 gnd 5 gnd 4 gnd www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 566 mt6000 /8000 series except mt6050i/mt8050i com1 rs232 9p d - sub fem ale com2 rs232 9p d - sub fem ale com3 rs232 9p d - sub m ale flexi soft cpu0 port0 4 p m ini - din male 2 rx 6 rx 8 rx 3 t x 3 tx 4 tx 7 tx 2 r x 5 gnd 5 gnd 5 gnd 4 gnd mt6050i/mt8050i com1 rs232 9p d - sub fem ale flexi soft cpu0 port0 4 p m ini - din ma le 9 rx 3 t x 6 tx 2 r x 5 gnd 4 gnd driver version : version date description v1. 0 0 apr/6/2011 driver released . www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 567 siemens logo (ethernet) supported series : siemens logo! 0ba7 website : h ttp://www.siemens.com/entry/cc/en/ hmi setting : parameters recommended options notes plc type siemens s7/200 (ethernet) plc i/f ethernet port no. 102 plc sta. no. 1 1~99 local tsap 1000 must be greater than 1000 remote tsap 2 1 00 range:2000~ 2700 for tsap settings please refer to plc setting below. plc setting : siemens logo! multi connection setting requires logo! soft comfort software to set plc to identify the connected devices. the following introduces logo! soft comfort settings. step 1. tools - > ethernet connections www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 568 step 2. right click on ethernet connections and click add connections to add a connection, up to eight connections are allowed. step 3. setting server i. double click on connection1 , then select server connection . ii. local tsap is system default and can t be modified. tick accept all connection requests to connect to any ip. iii. remote tsap set to 10.00 . iv. connection 2~8 can all be set as above. note : the value of local tsap and remote tsap must be set oppositely in easybuilder for communication . www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 569 step 4. complete settings, download connection to siemens logo! device address : bit/word device type format range memo b i dd 1~24 read only b q dd 1~16 b m dd 1~27 b v ddddo 0~1023 vw_bit w ai d 1~8 w aq d 1~2 w am d d 1~16 w vw dddd 0~1023 see table 1 address mapping www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 570 table 1 address mapping i v w q v w m v w ai v w aq v w am v w i1 v923.0 q1 v942.0 m1 v948.0 ai1 vw926 aq1 vw944 am1 vw952 i2 v923.1 q2 v942.1 m2 v948.1 ai2 vw928 aq2 vw946 am2 vw954 i3 v923.2 q3 v942.2 m3 v948.2 ai3 vw930 am3 vw956 i4 v923.3 q4 v942.3 m4 v948.3 ai4 vw932 am4 vw958 i5 v923.4 q5 v942.4 m5 v948.4 ai5 vw934 am5 vw960 i6 v923.5 q6 v942.5 m6 v948.5 ai6 vw936 am6 vw962 i7 v923.6 q7 v942.6 m7 v948 .6 ai7 vw938 am7 vw964 i8 v923.7 q8 v942.7 m8 v948.7 ai8 vw940 am8 vw966 i9 v924.0 q9 v943.0 m9 v949.0 am9 vw968 i10 v924.1 q10 v943.1 m10 v949.1 am10 vw970 i11 v924.2 q11 v943.2 m11 v949.2 am11 vw972 i12 v924.3 q12 v943.3 m12 v949.3 am12 vw974 i13 v924.4 q13 v943.4 m13 v949.4 am13 vw976 i14 v924.5 q14 v943.5 m14 v949.5 am14 vw978 i15 v924.6 q15 v943.6 m15 v949.6 am15 vw980 i16 v924.7 q16 v943.7 m16 v949.7 am16 vw982 i17 v925.0 m17 v9 50.0 i18 v925.1 m18 v950.1 i19 v925.2 m19 v950.2 i20 v925.3 m20 v950.3 i21 v925.4 m21 v950.4 i22 v925.5 m22 v950.5 i23 v925.6 m23 v950.6 i24 v925.7 m24 v950.7 m25 v951.0 m26 v951.1 m27 v951.2 www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 571 wiring diagram : direct connect (crossover cable): hmi rj45 m ale wire color plc rj45 m ale 1 tx+ white/orange 3 rx+ 2 tx - orange 6 rx - 3 rx+ white/green 1 tx+ 4 bd4+ blue 4 bd4+ 5 bd4 - white/blue 5 b d4 - 6 rx - green 2 tx - 7 bd3+ white/brown 7 bd3+ 8 bd3 - brown 8 bd3 - through a hub: hmi rj45 m ale wire color plc rj45 m ale 1 tx+ white/orange 1 tx+ 2 tx - orange 2 tx - 3 rx+ white/green 3 rx+ 4 bd4+ blue 4 bd4+ 5 bd4 - white/blue 5 bd4 - 6 rx - green 6 rx - 7 bd3+ white/brown 7 bd3+ 8 bd3 - brown 8 bd3 - driver version : version date description v1. 0 0 dec/7/2011 driver released. www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 572 siemens s7 - 1200 (ethernet) supported s eries: siemens s7 - 1 200 series ethernet . website: http://www.siemens.com/entry/cc/en/ hmi setting: parameters recommend ed option s notes plc type siemens s7 - 1200 (ethernet) siemens s7 - 400 (ethernet) plc i/f ethernet ethernet p ort n o. 102 102 plc s t a . n o. 2 2 rack - 0 cpu s lot - 1 on - line s imulat or yes multi - plc connect yes plc setting: 1. in s7 - 1200 program software create plc program and tag and then download to plc. 2. select go offline, e asy b uilder will connect to plc and get tag data. in plc type select siemens s7 - 1200 (ethernet). www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 573 3. click settings, input plc ip address. 4. check the plc that is not connected to any pc . click get tag info . www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 574 5. if the software used is a version later than tia portal v11 sp2, a dialog of functionblock directory will be sho wn, users have to define the mapping from fb to db in this directory then click check ok . the tag information will be gained and a successful message is shown. www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 575 6. create an object and click read address setting 7. in plc name select s7 - 1200 then click tag. 8. select plc tag. www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 576 support device type : s7 - 1200 d ata type e asy b uilder d ata format memo bool bit byte 16 - bit bcd, hex, binary, unsigned 8 - bit sint 16 - bit bcd, hex, binary, s igned 8 - bit usint 16 - bit bcd, hex, binary, uns igned 8 - bit word 1 6 - bit bcd, hex, binary, unsigned 16 - bit int 16 - bit bcd, hex, binary, signed 16 - bit uint 16 - bit bcd, hex, binary, unsigned 16 - bit dword 32 - bit bcd, hex, binary, unsigned 32 - bit d i nt 32 - bit bcd, hex, binary, signed 32 - bit real 32 - bit float 32 - bit udint 32 - bit bcd, hex, binary, unsigned 32 - bit array word array for ascii input and ascii display length=word wiring d iagram: direct connect (crossover cable): hmi rj45 m ale wire color plc rj45 m ale 1 tx+ white/orange 3 rx+ 2 tx - orange 6 rx - 3 rx+ white/ green 1 tx+ 4 bd4+ blue 4 bd4+ 5 bd4 - white/blue 5 bd4 - 6 rx - green 2 tx - 7 bd3+ white/brown 7 bd3+ 8 bd3 - brown 8 bd3 - www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 577 through a hub: hmi rj45 m ale wire color plc rj45 m ale 1 tx+ white/orange 1 tx+ 2 tx - orange 2 tx - 3 rx+ white/green 3 rx + 4 bd4+ blue 4 bd4+ 5 bd4 - white/blue 5 bd4 - 6 rx - green 6 rx - 7 bd3+ white/brown 7 bd3+ 8 bd3 - brown 8 bd3 - driver version : version date description v1. 70 oct/7/2011 add data type: byte,sint,uint,udint v1.90 apr/26/2012 add data type: usint www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 578 siemens s7 - 200 su pported s eries: siemens s7 - 200 series plc (cpu212/214/215/216/221/222/224/226/226xm) website: http://www.siemens.com/entry/cc/en/ hmi setting: parameters recommend ed option s notes plc type siemens s7 - 200 plc i/f rs 485 2w rs485 2w baud rate 9600 9600, 19200 , 187.5k the hmi which has a st icker mpi187.5 on the rear cover support s 187.5 k data b its 8 7, 8 parity even even, odd, none stop b its 1 1 , 2 plc s t a . n o. 2 1 ~ 126 t urn around delay (ms) 5 send ack delay(ms) 30 online s imulator yes extend address mode no broadcast command no plc setting: communication mode set station number to 2 device a ddress: bit/word device t ype format range memo b i ddddo 0 ~ 40957 input (i) b q ddddo 0 ~ 40957 output (o) b m ddddo 0 ~ 40957 bit memory b vw _ b it dddddo 0 ~ 102397 v memory b it a ddress byte vb ddddd 0 ~ 10239 www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 579 bit/word device t ype format range memo w vw ddddd 0 ~ 10239 v m emory w vw _odd ddddd 0 ~ 10239 v m emory dw vd ddddd 0 ~ 10239 v m emory d ouble w ord dw vd_odd ddddd 0 ~ 10239 v m emory d ouble w ord w vw_string ddddd 0 ~ 10239 string w vw_string_odd ddddd 0 ~ 10239 string d w vd_string ddddd 0 ~ 10239 string d w vd_string_odd ddddd 0 ~ 10239 string byte mb ddddd 0 ~ 10239 b yte m emory w mw ddddd 0 ~ 10239 word m emory d w md ddddd 0 ~ 10239 word m emory w mw_odd ddddd 0 ~ 10239 word m emory w t ddd 0 ~ 127 timer w c ddd 0 ~ 127 counter ? double word and f loating point value must use vd device type. wiring d iagram: the following represents the view of hmi & plc. e mt 3 000 series com1 rs485 2 w 9p d - sub m ale com 3 rs485 2 w 9p d - sub m ale rs 485 2w 9p d - sub male 1 rx - 6 data - 8 d - 2 rx+ 9 data+ 3 d+ 5 gnd 5 gnd 5 gnd mt6000 /8000 series except mt6050i/mt8050i com1 rs485 2 w 9p d - sub m ale com 3 r s485 2 w 9p d - sub m ale rs 485 2w 9p d - sub male 1 rx - 6 data - 8 d - 2 rx+ 9 data+ 3 d+ 5 gnd 5 gnd 5 gnd www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 580 mt6050i/mt8050i com1 rs485 2 w 9p d - sub fem ale com 3 rs485 2 w 9p d - sub fem ale rs 485 2w 9p d - sub male 1 rx - 7 data - 8 d - 2 rx+ 8 data+ 3 d+ 5 gnd 5 gnd 5 gnd driver version : version date description v2.30 aug/17/2009 v2.40 nov/1/2011 add device type : md www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 581 siemens s7 - 200 (ethernet) supported series: siemens s7/200 ethernet series plc (cpu212/214/215/216/221/222/224/226/226xm ) with cp243 - 1 ethernet module website: http://www.siemens.com/entry/cc/en/ hmi setting: parameters recommend ed option s notes plc type s iemens s7 - 200 (ethernet) plc i/f ethernet port n o. 102 p lc s t a . n o. 1 0 - 31 plc setting : s7 / 200 ethernet multi - connection settings step 1: launching the ethernet wizard 1. in the micro/win main menu, click tools / ethernet wizard . www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 582 2. then, click next . 3. click yes to proceed. step 2: setting cp243 - 1 module p osition 1. click read modules . www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 583 2. to view the results of read modules, select the ethernet module . click next . step 3: assigning module address 1. click next . www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 584 2. enter the number of desired available connections for this device. if 0 is entered, the only conn ection available will be the pg mode . the image below shows there are 4 connections for this module. 3. connection0 - > select this is a server connection... . notice the local tsap automatically incremented to 1 0 .00 . www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 585 4. connection1 select this is a server c onnection... . notice the local tsap automatically incremented to 1 1 .00 . 5. upon completion of the settings above, set parameters in e asybuilder . set the value of local tsap here to the value of remote tsap in micro/win and vice versa to realize multi - conne ction. www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 586 device a ddress: bit/word device t ype format range memo b i ddddo 0 ~ 40957 input (i) b q ddddo 0 ~ 40957 output (o) b m ddddo 0 ~ 40957 bit memory b vw _ b it dddd d o 0 ~ 102397 v memory b it a ddress w vw ddddd 0 ~ 1023 9 v m emory dw vd ddddd 0 ~ 1023 9 v m emory d ouble w ord w vw _string ddddd 0 ~ 1023 9 string dw vd_string ddddd 0 ~ 1023 9 string d w md ddddd 0 ~ 10239 word m emory ? double word and f loating point value must use vd device type. wiring d iagram: direct connect (crossover cable): hmi r j45 m ale wire color plc rj45 m ale 1 tx+ white/orange 3 rx+ 2 tx - orange 6 rx - 3 rx+ white/green 1 tx+ 4 bd4+ blue 4 bd4+ 5 bd4 - white/blue 5 bd4 - 6 rx - green 2 tx - 7 bd3+ white/brown 7 bd3+ 8 bd3 - brown 8 bd3 - www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 587 through a hub: hmi rj45 m ale w ire color plc rj45 m ale 1 tx+ white/orange 1 tx+ 2 tx - orange 2 tx - 3 rx+ white/green 3 rx+ 4 bd4+ blue 4 bd4+ 5 bd4 - white/blue 5 bd4 - 6 rx - green 6 rx - 7 bd3+ white/brown 7 bd3+ 8 bd3 - brown 8 bd3 - driver version : version date description v1.20 dec/30/2008 v1.40 nov/15/2011 add device type : md www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 588 siemens s7 - 200 (vd any address) su pported s eries: siemens s7 - 200 series plc (cpu212/214/215/216/221/222/224/226/226xm) website: http://www .siemens.com/entry/cc/en/ hmi setting: parameters recommend ed option s notes plc type siemens s7 - 200 (vd any address) plc i/f rs 485 2w rs485 2w baud rate 9600 9600, 19200 , 187.5k the hmi which has a st icker mpi187.5 on the rear cover support s 187.5 k data b its 8 7, 8 parity even even, odd, none stop b its 1 1 , 2 plc s t a . n o. 2 1 ~ 126 turn around delay (ms) 5 reserved 1 30 ack delay time online s imulator yes extend address mode no broadcast command no plc setting: communication mode set station number to 2 device a ddress: bit/word device t ype format range memo b i ddddo 0 ~ 40957 input (i) b q ddddo 0 ~ 40957 output (o) b m ddddo 0 ~ 40957 bit memory b vw _ b it dddddo 0 ~ 102397 v memory b it a ddress w vw ddddd 0 ~ 10239 v m emory www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 589 bit/word device t ype format range memo dw vd ddddd 0 ~ 10239 v m emory d ouble w ord w vw_string ddddd 0 ~ 10239 string d w vd_string ddddd 0 ~ 10239 string w mw ddddd 0 ~ 10239 word m emory w t ddd 0 ~ 127 timer w c ddd 0 ~ 127 counter dw md ddddd 0 ~ 10239 word m emory ? double word and f loa ting point value must use vd device type. ? vd register can set to any value, not necessarily a multiple of 4. wiring d iagram: the following represents the view of hmi & plc. e mt 3 000 series com1 rs485 2 w 9p d - sub m ale com 3 rs485 2 w 9p d - sub m ale rs 485 2w 9 p d - sub male 1 rx - 6 data - 8 d - 2 rx+ 9 data+ 3 d+ 5 gnd 5 gnd 5 gnd mt6000 /8000 series except mt6050i/mt8050i com1 rs485 2 w 9p d - sub m ale com 3 rs485 2 w 9p d - sub m ale rs 485 2w 9p d - sub male 1 rx - 6 data - 8 d - 2 rx+ 9 data+ 3 d+ 5 gnd 5 gnd 5 gnd www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 590 mt6050i/mt8050i com1 rs485 2 w 9p d - sub fem ale com 3 rs485 2 w 9p d - sub fem ale rs 485 2w 9p d - sub male 1 rx - 7 data - 8 d - 2 rx+ 8 data+ 3 d+ 5 gnd 5 gnd 5 gnd driver version : version date description v1.20 nov/16/2011 a dd device type : md www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 591 siemens s7 - 200 ppi supported s eries: siemens s7 - 200 series plc (cpu212/214/215/216/221/222/224/226/226xm) website : http://www.siemens.com/entry/cc/en/ hmi setting : parameters reco mmend ed option s notes plc type siemens s7 - 200 ppi plc i/f rs 485 2w rs485 2w baud rate 9600 9600, 19200 , 187.5k only m t6000/8000v2 support baud rate 187.5 k data b its 8 7, 8 parity even even, odd, none stop b its 1 1 , 2 turn around delay (ms) 5 ack delay time (ms) 30 plc s t a . n o. 2 1 ~ 126 online simulator yes extend address mode yes broadcast command no plc setting: plc setting plc st a . no. can not be the same as hmi st a . no. device address: bit/word device t ype format range memo b i ddddo 0 ~ 40957 input (i) b q ddddo 0 ~ 40957 output (o) b m ddddo 0 ~ 40957 bit memory b vw _ b it dddddo 0 ~ 102397 v m emory b it a ddress byte vb ddddd 0 ~ 10239 w vw ddddd 0 ~ 10239 v m emory www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 592 bit/word device t ype format range memo w vw _odd ddddd 0 ~ 10239 v m emory dw vd ddddd 0 ~ 102 39 v m emory d ouble w ord dw vd_odd ddddd 0 ~ 10239 v m emory d ouble w ord w vw_string ddddd 0 ~ 10239 string w vw_string_odd ddddd 0 ~ 10239 string d w vd_string ddddd 0 ~ 10239 string d w vd_string_odd ddddd 0 ~ 10239 string byte mb ddddd 0 ~ 10239 b yte m emory w mw ddddd 0 ~ 10239 word m emory w mw_odd ddddd 0 ~ 10239 word m emory w t ddd 0 ~ 127 timer w c ddd 0 ~ 127 counter d w md ddddd 0 ~ 10239 word memory ? double w ord and f loating p oint value must use vd device type. multi - hmis - multi - plcs communi cation setting: for s7 - 200 plc, multi - hmis - multi - plcs communication can be achieved using s7/200 ppi driver, please refer to the settings below. www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 593 in e asybuilder com port settings, two important parameters must be set: 1. [high station address ( h sa )] : s et ting max. station number of hmi in ppi network. for the effectiveness of system operation, it is highly recommended that the hmi station number starts from zero and go on sequentially . if there are 4 hmi in ppi network, set station no. from 0~3, and [high station address ( h sa)] to 3. set hmi station number in [system parameters] / [model] / [hmi station no.]: 2. [gap update factor(guf)]: the condition to pass a token. in ppi network only hmi can hold a token, plc can only be controlled . when the hmi that ho lds token communicates with plc for a number of times that equals to the value set here, hmi will pass the token (control of plc) to the next hmi. for example, if guf is set to 1 , hmi will pass the control of plc to the next hmi when read or write the va lue in an address. if guf is set to a bigger value, the hmi that holds token will control the plc for a longer time and therefore the token won t be passed to another hmi and cause failure in communicating with plc. a complete communication means hmi reads / writes plc value for one time. www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 594 note: ? hmi st a . no. can not be the same as plc st a . no. ? highly recommended that hmi st a . no. starts from 0 and go on sequentially for the effectiveness of operation. ? available for e asybuilder v4.50 and later. wiring diagr am: the following represents the view of hmi & plc. e mt 3 000 series com1 rs485 2 w 9p d - sub m ale com 3 rs485 2 w 9p d - sub m ale rs 485 2w 9p d - sub male 1 rx - 6 data - 8 d - 2 rx+ 9 data+ 3 d+ 5 gnd 5 gnd 5 gnd mt6000 /8000 series except mt6050i/mt80 50i com1 rs485 2 w 9p d - sub m ale com 3 rs485 2 w 9p d - sub m ale rs 485 2w 9p d - sub male 1 rx - 6 data - 8 d - 2 rx+ 9 data+ 3 d+ 5 gnd 5 gnd 5 gnd mt6050i/mt8050i com1 rs485 2 w 9p d - sub fem ale com 3 rs485 2 w 9p d - sub fem ale rs 485 2w 9p d - sub male 1 rx - 7 data - 8 d - 2 rx+ 8 data+ 3 d+ 5 gnd 5 gnd 5 gnd www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 595 driver version version date description v 1.00 aug/1 5 /20 11 driver released. v1.10 nov/17/2011 add device type : md www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 596 siemens s7 - 300 supported s eries: siemens s7 - 300 series plc websit e: http://www.siemens.com/entry/cc/en/ hmi setting: parameters recommend ed option s notes plc type siemens s7 - 300 plc i/f rs 232 baud rate 19200 9600 ~ 187.5k must be same as the plc setting . the hmi which has a st icker mpi187.5 on the rear cover support s 187.5 k. data b its 8 parity odd stop b its 1 plc s t a . n o. 2 must be same as the plc setting . device a ddress: bit/word device t ype format range memo b i ddddo 0 ~ 40957 input (i) b q ddddo 0 ~ 40957 output (o) b m ddddo 0 ~ 40957 bit memory b d b n bit ffffddddo 0 ~ 409681927 data r egister b it b db0bit ~ db99bit ddddo 0 ~ 81927 w iw dddd 0 ~ 4095 input (i) w qw dddd 0 ~ 4095 output (o) w mw dddd 0 ~ 4095 bit memory d w md dddd 0 ~ 4094 byte mb dddd 0 ~ 4095 bit memory byte byte dbbn ffffdddd 0 ~ 40968192 data r egister byte w dbn ffffdddd 0 ~ 4096 8192 data r egister (must be even) www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 597 bit/word device t ype format range memo d w d b dn ffffdddd 0 ~ 4096 8192 data r egister d ouble w ord (must be multiple of 4) w dbn_string ffffdddd 0 ~ 4096 8192 data r egister d ouble w ord (must be multiple of 4) dw dbdn_string ffffdddd 0 ~ 4096 8192 data r egister d ouble w ord (must be multiple of 4) w db0 - db99 dddd 0 ~ 8192 data r egister (must be even) * double word and f loating point v alue must use dbdn device type. how to import tag : siemens step 7 program allows building files of user - defined tag ( *.dif file and *.awl file), and import the se files in easybuilder8000/easybuilderpro - > system parameter settings. the following describes how to build and import these two types of files. 1. building * .dif file a in symbols create user - defined tag. www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 598 b click export to export the edited file and click save . 2. building * .awf file a in blocks create items as shown below: b open lad/stl , fbd C programming s7 b l ock s , click file - > generate source . www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 599 c select sources as storage path, specify the file name then click ok . d select the objects to be exported then click ok . www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 600 e u nder sources there will be names of the saved files, select export s ource to build *. a wl file. t he generated *. dif and *. awl files can be imported in easybuilder8000/easybuilderpro system parameter settings , by clicking import tag . tag information successfully imported. www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 601 wiring d iagram: the following represents the view of hmi & pl c. siemens s7 - 300 pc adapter : 9p d - sub to 9p d - sub: e mt 3 000 series com1 rs232 9p d - sub fem ale com 3 rs232 9p d - sub fem ale rs232 9 p d - sub male 2 rx 8 rx 3 t x d 3 tx 7 tx 2 r x d 5 gnd 5 gnd 5 gnd 7 rts circuit 8 cts mt6000 /8000 series except mt6050i/mt8050i com1 rs232 9p d - sub fem ale com2 rs232 9p d - sub fem ale com3 rs232 9p d - sub m ale rs232 9 p d - sub male 2 rx 6 rx 8 rx 3 t x d 3 tx 4 tx 7 tx 2 r x d 5 gnd 5 gnd 5 gnd 5 gnd 7 rts circuit 8 cts mt6050i/mt8050i com1 rs232 9p d - sub fem ale rs232 9 p d - sub male 9 rx 3 t x d 6 tx 2 r x d 5 gnd 5 gnd 7 rts circuit 8 cts www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 602 the following represents the view of hmi & plc. systeme helmholz ssw7 - ts : 9p d - sub to 9p d - sub e mt 3 000 series com1 rs232 9p d - sub fem ale com 3 rs232 9p d - sub fem ale rs232 9 p d - sub male 2 rx 8 rx 3 t x d 3 tx 7 tx 2 r x d 5 gnd 5 gnd 5 gnd 7 rts circuit 8 cts 4 dtr circuit 6 dsr mt6000 /8000 series except mt6050i/mt8050i com1 rs232 9p d - sub fem ale com2 rs232 9p d - sub fem al e com3 rs232 9p d - sub m ale rs232 9 p d - sub male 2 rx 6 rx 8 rx 3 t x d 3 tx 4 tx 7 tx 2 r x d 5 gnd 5 gnd 5 gnd 5 gnd 7 rts circuit 8 cts 4 dtr circuit 6 dsr www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 603 mt6050i/mt8050i com1 rs232 9p d - sub fem ale rs232 9 p d - sub male 9 rx 3 t x d 6 tx 2 r x d 5 gnd 5 gnd 7 rts circuit 8 cts 4 dtr circuit 6 dsr driver version : version date description v 3.10 may / 24 /201 1 a dd ed register s: mb & dbbn. www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 604 siemens s7 - 300 mpi supported s eries: siemens s7 - 300 series plc website : http://www.siemens.com/entry/cc/en/ hmi setting: parameters recommend ed option s notes plc type siemens s7 - 300 mpi plc i/f rs - 485 2 w baud rate 187.5k only hmi with a sticker mpi 187.5k on the rear c over supports mpi communication. data b its 8 parity even stop b its 1 plc s t a . n o. 2 2 ~ 31 online simulator no extend address mode yes ( x series does not support ) broadcast command no device address: bit/word device t ype format range memo b i ddddo 0 ~ 40957 input (i) b q ddddo 0 ~ 40957 output (o) b m ddddo 0 ~ 40957 bit memory b dbnbit ffffddddo 0 ~ 4096 9999 7 data r egister b it b d b0bit ~ d b 9 9bit dddddo 0 ~ 655327 data r egister b it w iw dddd 0 ~ 4095 input (i) w qw dddd 0 ~ 4095 ou tput (o) w mw dddd 0 ~ 4095 bit memory d w md dddd 0 ~ 4094 byte mb dddd 0 ~ 4095 bit memory byte byte dbbn ffffdddd 0 ~ 40969999 data r egister w dbn ffffdddd 0 ~ 4096 9999 data r egister ( must be even) www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 605 bit/word device t ype format range memo d w d b dn ffffdddd 0 ~ 4096 9999 data r egister d oubl e w ord ( multiple of 4) w dbn_string ffffdddd 0 ~ 4096 9999 d w dbdn_string ffffdddd 0 ~ 4096 9999 w db0 ~ db99 ddddd 0 ~ 65532 data r egister ( must be even) ? double w ord and f loating p oint value must use dbdn device type. multi - hmis - multi - plcs communicat ion setting: for siemens s7 - 300 mpi driver in multi - hmis - multi - plcs communication , [max. station no. (mpi network)] parameter must be correctly set. this setting is relevant to the station no. of the devices, as shown, two hmi (station no. 0 , 1 ) and two plc (station no. 2, 3) are in mpi network, max. station no. should be set to 3. www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 606 f o r the effectiveness of communication, users may set plc device in step 7 as shown below. in properties mpi / network settings, set highest mpi address to the number closes t to the actual device station number. hmi st a . no. can not be the same as plc st a . no. h i ghly recommended that the device station numbers start from 0 sequentially and correctly set [max. station no. (mpi network)]. available for e asybuilder v4. 50 and later. x series does not support multiple - hmi - to - multiple - plc communication, and supports only 1 - hmi - to - 1 - plc communication. how to import tag : siemens step 7 program allows building files of user - defined tag ( *.dif file and *.awl file), and impo rt these files in easybuilder8000/easybuilderpro - > system parameter settings. the following describes how to build and import these two types of files. www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 607 1. building * .dif file a in symbols create user - defined tag. b click export to export the edited file a nd click save . www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 608 2. building *.awf file a in blocks create items as shown below: b open lad/stl , fbd C programming s7 b lock s , click file - > generate source . c select sources as storage path, specify the file name then click ok . www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 609 d select the objects to be exported then click ok . e u nder sources there will be names of the saved files, select export s ource to build *.awl file. www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 610 t he generated *. dif and *. awl files can be imported in easybuilder8000/easybuilderpro system parameter settings , by clicking impo rt tag . tag information successfully imported. www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 611 wiring diagram: the following represents the view of hmi & plc. s7 - 200 ppi , s7 - 300 mpi :rs485 2w e mt 3 000 series com1 rs485 2 w 9p d - sub m ale com 3 rs485 2 w 9p d - sub m ale rs 485 2w 9p d - sub male 1 rx - 6 data - 8 d - 2 rx+ 9 data+ 3 d+ 5 gnd 5 gnd 5 gnd mt6000 /8000 series except mt6050i/mt8050i com1 rs485 2 w 9p d - sub m ale com 3 rs485 2 w 9p d - sub m ale rs 485 2w 9p d - sub male 1 rx - 6 data - 8 d - 2 rx+ 9 data+ 3 d+ 5 gnd 5 gnd 5 gnd m t6050i/mt8050i com1 rs485 2 w 9p d - sub fem ale com 3 rs485 2 w 9p d - sub fem ale rs 485 2w 9p d - sub male 1 rx - 7 data - 8 d - 2 rx+ 8 data+ 3 d+ 5 gnd 5 gnd 5 gnd driver version: version date description v1. 9 0 may/26/2011 added registers: mb & dbb n v2.00 aug/19d/2011 i series hmi support multi hmis - multi plcs communication. www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 612 siemens s7 - 300/et200s (ethernet) supported s eries: siemens s7 - 300 ethernet series plc , ethernet module cp - 343 - 1, cpu315 - 2 pn/dp, cpu317 - 2 pn/dp, cpu319 - 3 pn/dp , and et200s. w ebsite: http://www.siemens.com/entry/cc/en/ hmi setting: parameters recommend ed option s notes plc type siemens s7 - 300/et200s (ethernet) plc i/f ethernet port n o. 102 plc s t a . n o. 1 0 - 31 devi ce a ddress: bit/word device t ype format range memo b i ddddo 0 ~ 40957 input (i) b q ddddo 0 ~ 40957 output (o) b m ddddo 0 ~ 40957 bit memory b dbnbit ffffddddo 0 ~ 4096 9999 7 b d b0bit - d b 9 9bit dddddo 0 ~ 655327 data r egister b it w iw dddd 0 ~ 4095 i nput (i) w qw dddd 0 ~ 4095 output (o) w mw dddd 0 ~ 4095 bit memory d w md dddd 0 ~ 4094 bit memory double w ord dw md_anyaddr dddd 0 ~ 4094 bit memory double word (must be even) w dbn ffffdddd 0 ~ 4096 9999 data r egister (must be even) d w d b dn ffff dddd 0 ~ 4096 9999 data r egister d ouble w ord (must be multiple of 4) dw dbdn_anyaddr ffffdddd 0 ~ 40969999 data r egister d ouble w ord ( must be even ) w dbn_string ffffdddd 0 ~ 4096 9999 dw dbdn_string ffffdddd 0 ~ 4096 9999 w db0 ~ db99 ddddd 0 ~ 65532 data r egister www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 613 bit/word device t ype format range memo (must be even) byte mb dddd 0 ~ 4095 bit memory byte byte dbbn ffffdddd 0 ~ 40969999 data r egister byte ? double word and f loating point value must use dbdn device type. how to import tag : siemens step 7 program allows building files of use r - defined tag ( *.dif file and *.awl file), and import these files in easybuilder8000/easybuilderpro - > system parameter settings. the following describes how to build and import these two types of files. 1. building * .dif file a in symbols create user - defin ed tag. www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 614 b click export to export the edited file and click save . 2. building *.awf file a in blocks create items as shown below: b open lad/stl , fbd C programming s7 b lock s , click file - > generate source . www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 615 c select sources as storage path, specify the file name then click ok . d select the objects to be exported then click ok . www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 616 e u nder sources there will be names of the saved files, select export s ource to build *.awl file. t he generated *. dif and *. awl files can be imported in easybuilder8000/easy builderpro system parameter settings , by clicking import tag . tag information successfully imported. www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 617 wiring d iagram: direct connect (crossover cable): hmi rj45 m ale wire color plc rj45 m ale 1 tx+ white/orange 3 rx+ 2 tx - orange 6 rx - 3 rx+ whit e/green 1 tx+ 4 bd4+ blue 4 bd4+ 5 bd4 - white/blue 5 bd4 - 6 rx - green 2 tx - 7 bd3+ white/brown 7 bd3+ 8 bd3 - brown 8 bd3 - through a hub: hmi rj45 m ale wire color plc rj45 m ale 1 tx+ white/orange 1 tx+ 2 tx - orange 2 tx - 3 rx+ white/green 3 r x+ 4 bd4+ blue 4 bd4+ 5 bd4 - white/blue 5 bd4 - 6 rx - green 6 rx - 7 bd3+ white/brown 7 bd3+ 8 bd3 - brown 8 bd3 - driver version : version date description v2.10 may / 21 /201 1 add ed register s: mb & dbbn. v2.20 apr/25/2012 added registers: md_anyadd r & dbdn_anyaddr. www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 618 siemens s7 - 400 (ethernet) supported s eries: siemens s7 - 4 00 /1200 ethernet plc . website: http://www.siemens.com/entry/cc/en/ hmi setting: parameters recommend ed option s notes plc type siemens s7 - 400 (ethernet) plc i/f ethernet port n o. 102 link t ype pg pc, op rack 0 0 - 7 cpu s lot 3 1 - 31 to connect with s7 - 1200,slot 1 must be selected. plc s t a . n o. 0 0 - 31 device a ddress: bit/word device t ype format range memo b i ddddo 0 ~ 40957 input (i) b q ddddo 0 ~ 40957 output (o) b m ddddo 0 ~ 40957 bit memory b dbnbit fff f fddddo 0 ~ 65535 9999 7 b d b0bit - d b 9 9bit dddddo 0 ~ 655327 data r egister b it w iw dddd 0 ~ 4095 input (i) w qw dddd 0 ~ 4095 output (o) w mw dddd 0 ~ 4095 bi t memory d w md dddd 0 ~ 4094 w dbn ffff f dddd 0 ~ 65535 9999 data r egister (must be even) d w d b dn ffff f dddd 0 ~ 65535 9999 data r egister d ouble w ord (must be multiple of 4) w dbn_string fff f fdddd 0 ~ 65535 9999 dw dbdn_string fff f fdddd 0 ~ 65535 9999 w db0 ~ db99 ddddd 0 ~ 65532 data r egister (must be even) byte mb dddd 0 ~ 4095 bit memory byte byte dbbn fffff dddd 0 ~ 65535 9999 data r egister byte * double word and f loating point value must use dbdn device type. www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 619 wiring d iagram: direct connect (crosso ver cable): hmi rj45 m ale wire color plc rj45 m ale 1 tx+ white/orange 3 rx+ 2 tx - orange 6 rx - 3 rx+ white/green 1 tx+ 4 bd4+ blue 4 bd4+ 5 bd4 - white/blue 5 bd4 - 6 rx - green 2 tx - 7 bd3+ white/brown 7 bd3+ 8 bd3 - brown 8 bd3 - through a hub: hmi rj45 m ale wire color plc rj45 m ale 1 tx+ white/orange 1 tx+ 2 tx - orange 2 tx - 3 rx+ white/green 3 rx+ 4 bd4+ blue 4 bd4+ 5 bd4 - white/blue 5 bd4 - 6 rx - green 6 rx - 7 bd3+ white/brown 7 bd3+ 8 bd3 - brown 8 bd3 - www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 620 e asy b uilder device sett ing steps 1. open e asy b uilder , file / new, select hmi model a nd press [ok ] . 2. s ystem p arameter s ettings window is shown , click [ new ] . 3. select siemens s7 - 400(ethernet) . 4. press [ settings ] . www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 621 5. set s7 - 400 ip, port no. , link type, rack and cpu slot. ( must match plc settings ) 6. the setting will be finished a s below . www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 622 how to import tag : siemens step 7 program allows building files of user - defined tag ( *.dif file and *.awl file), and import these files in easybuilder8000/easybuilderpro - > system parameter setti ngs. the following describes how to build and import these two types of files. 1. building * .dif file a in symbols create user - defined tag. b click export to export the edited file and click save . www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 623 2. building *.awf file a in blocks create items as shown below: b open lad/stl , fbd C programming s7 b lock s , click file - > generate source . c select sources as storage path, specify the file name then click ok . www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 624 d select the objects to be exported then click ok . e u nder sources there will be names of the saved file s, select export s ource to build *.awl file. www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 625 t he generated *. dif and *. awl files can be imported in easybuilder8000/easybuilderpro system parameter settings , by clicking import tag . tag information successfully imported. driver version : version d ate description v1. 4 0 may / 25 /201 1 add ed register s: mb & dbbn v1.50 aug/03/2012 d evice types dbn, dbdn is extended to 655359999. www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 626 siemens ti505 supported s eries: simatic ti505 series plcs: ti520, ti525, ti530, ti535, ti545, ti555, ti560, ti565, ti575 . us e ni tp protocol in a point - to - point , single master, single slave format. website: http://www.siemens.com/entry/cc/en/ hmi setting: parameters recommend ed option s notes plc type simatic ti505 nitp prot ocol plc i/f rs232 rs232, rs485(4w) baud rate 19200 19200 data b its 7 7 parity odd odd stop b its 1 1 plc s t a. n o. 0 does not apply device a ddress: bit/word device t ype format range memo b cr ddddd 1 ~ 65535 internal relay b x ddddd 1 ~ 6553 5 discrete i nput c oils b y ddddd 1 ~ 65535 discrete o utput c oils w v ddddd 1 ~ 65535 user d ata r egisters w stw ddddd 1 ~ 65535 status w ord r egisters w tcp ddddd 1 ~ 65535 timer/ c ounter p reset v alues w tcc ddddd 1 ~ 65535 timer/ c ounter c urrent v alues w wx ddddd 1 ~ 65535 word d iscrete i nputs w wy ddddd 1 ~ 65535 word d iscrete o utputs www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 627 wiring d iagram: the following represents the view of hmi & plc. simatic ti505 rs232 : 9p d - sub to 25p d - sub e mt 3 000 series com1 rs232 9p d - sub fem ale com 3 rs232 9p d - s ub fem ale rs232 25p d - sub male 2 rx 8 rx 2 tx d 3 tx 7 tx 3 rx d 5 gnd 5 gnd 7 gnd 4 rts circuit 5 cts 6 dsr circuit 8 dcd 20 dtr mt6000 /8000 series except mt6050i/mt8050i com1 rs232 9p d - sub fem ale com2 rs232 9p d - sub fem ale com 3 rs232 9p d - sub m ale rs232 25p d - sub male 2 rx 6 rx 8 rx 2 tx d 3 tx 4 tx 7 tx 3 rx d 5 gnd 5 gnd 5 gnd 7 gnd 4 rts circuit 5 cts 6 dsr circuit 8 dcd 20 dtr www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 628 mt6050i/mt8050i com1 rs232 9p d - sub fem ale rs232 25p d - sub male 9 rx 2 tx d 6 tx 3 rx d 5 gnd 7 gnd 4 rts circuit 5 cts 6 dsr circuit 8 dcd 20 dtr the following represents the view of hmi & plc. simatic ti505 rs232 : 9p d - sub to 9 p d - sub e mt 3 000 series com1 rs232 9p d - sub fem ale com 3 rs232 9p d - s ub fem ale rs232 9 p d - sub male 2 rx 8 rx 3 t x d 3 tx 7 tx 2 r x d 5 gnd 5 gnd 5 gnd 7 rts circuit 8 cts 1 dcd circuit 4 dtr 6 dsr www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 629 mt6000 /8000 series except mt6050i/mt8050i com1 rs232 9p d - sub fem ale com2 rs232 9p d - sub fem ale com 3 rs232 9p d - sub m ale rs232 9 p d - sub male 2 rx 6 rx 8 rx 3 t x d 3 tx 4 tx 7 tx 2 r x d 5 gnd 5 gnd 5 gnd 5 gnd 7 rts 7 rts 8 cts 8 cts 1 dcd 1 dcd 4 dtr 4 dtr 6 dsr mt6050i/mt8050i com1 rs232 9p d - sub fem ale rs232 9 p d - sub male 9 rx 3 t x d 6 tx 2 r x d 5 gnd 5 gnd 7 rts circuit 8 cts 1 dcd circuit 4 dtr 6 dsr www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 630 the following represents the view of hmi & plc. simatic ti505 rs 485 4w : 9p d - sub to 9p d - sub e mt 3 000 series com1 rs485 4 w 9p d - sub m ale rs485 4w 9p d - sub male 1 rx - 7 do ( - ) 2 r x + 1 do (+) 3 tx - 8 di ( - ) 4 tx+ 5 di (+) 5 gnd 6 gnd mt6000 /8000 series except mt6050i/mt8050i com1 rs485 4 w 9p d - sub m ale rs485 4w 9p d - sub male 1 rx - 7 do ( - ) 2 r x + 1 do (+) 3 tx - 8 di ( - ) 4 tx+ 5 di (+) 5 gnd 6 gnd mt6050i/mt8050i com1 rs485 4 w 9p d - sub fem ale rs485 4w 9p d - sub male 1 rx - 7 do ( - ) 2 r x + 1 do (+) 3 tx - 8 di ( - ) 4 tx+ 5 di (+) 5 gnd 6 gnd www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 631 driver version : version date description v1.10 apr/22/2009 www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 632 siemens ti565/c400 website: http://www.siemens.com/entry/cc/en/ hmi setting: parameters recommend ed option s notes plc type simatic ti565/c400 plc i/f rs232 rs232, rs485(4w) b aud rate 19200 19200 data b its 7 7 parity odd odd stop b its 1 1 plc s t a. n o. 0 does not apply device a ddress: bit/word device t ype format range memo b cr ddddd 1 ~ 65535 internal relay b x ddddd 1 ~ 65535 discrete i nput c oils b y ddddd 1 ~ 65535 discrete o utput c oils b v_bit ddddddd 1 00 ~ 6553515 user d ata r egisters w v ddddd 1 ~ 65535 user d ata r egisters w stw ddddd 1 ~ 65535 status w ord r egisters w tcp ddddd 1 ~ 65535 timer/ c ounter p reset v alues w tcc ddddd 1 ~ 65535 timer/ c ou nter c urrent v alues w wx ddddd 1 ~ 65535 word d iscrete i nputs w wy ddddd 1 ~ 65535 word d iscrete o utputs www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 633 wiring d iagram: the following represents the view of hmi & plc. 9p d - sub to 25p d - sub: rs232 e mt 3 000 series com1 rs232 9p d - sub fem ale com 3 rs232 9p d - sub fem ale rs232 25p d - sub male 2 rx 8 rx 2 tx d 3 tx 7 tx 3 rx d 5 gnd 5 gnd 7 gnd 4 rts circuit 5 cts 6 dsr circuit 8 dcd 20 dtr mt6000 /8000 series except mt6050i/mt8050i com1 rs232 9p d - sub fem ale com2 rs232 9p d - s ub fem ale com3 rs232 9p d - sub m ale rs232 25p d - sub male 2 rx 6 rx 8 rx 2 tx d 3 tx 4 tx 7 tx 3 rx d 5 gnd 5 gnd 5 gnd 7 gnd 4 rts circuit 5 cts 6 dsr circuit 8 dcd 20 dtr www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 634 mt6050i/mt8050i com1 rs232 9p d - sub fem ale rs232 25p d - su b male 9 rx 2 tx d 6 tx 3 rx d 5 gnd 7 gnd 4 rts circuit 5 cts 6 dsr circuit 8 dcd 20 dtr the following represents the view of hmi & plc. 9p d - sub to 9p d - sub: rs232 e mt 3 000 series com1 rs232 9p d - sub fem ale com 3 rs232 9p d - sub fem ale rs232 9 p d - sub male 2 rx 8 rx 3 t x d 3 tx 7 tx 2 r x d 5 gnd 5 gnd 5 gnd 7 rts circuit 8 cts 1 dcd circuit 4 dtr 6 dsr www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 635 mt6000 /8000 series except mt6050i/mt8050i com1 rs232 9p d - sub fem ale com2 rs232 9p d - sub fem ale com3 rs232 9p d - sub m ale rs232 9 p d - sub male 2 rx 6 rx 8 rx 3 t x d 3 tx 4 tx 7 tx 2 r x d 5 gnd 5 gnd 5 gnd 5 gnd 7 rts circuit 8 cts 1 dcd circuit 4 dtr 6 dsr mt6050i/mt8050i com1 rs232 9p d - sub fem ale rs232 9 p d - sub male 9 rx 3 t x d 6 tx 2 r x d 5 gnd 5 gnd 7 rts circuit 8 cts 1 dcd circuit 4 dtr 6 dsr www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 636 the following represents the view of hmi & plc. 9p d - sub to 9p d - sub: rs - 485 4w e mt 3 000 series com1 rs485 4 w 9p d - sub m ale rs 485 4w 9 p d - sub male 1 rx - 7 do ( - ) 2 r x + 1 do (+) 3 tx - 8 di ( - ) 4 tx+ 5 di (+) 5 gnd 6 gnd mt6000 /8000 series except mt6050i/mt8050i com1 rs485 4 w 9p d - sub m ale rs 485 4w 9 p d - sub male 1 rx - 7 do ( - ) 2 r x + 1 do (+) 3 tx - 8 di ( - ) 4 tx+ 5 di (+) 5 gnd 6 gnd mt6050i/mt8050i com1 rs485 4 w 9p d - sub fem ale rs 485 4w 9 p d - sub male 1 rx - 7 do ( - ) 2 r x + 1 do (+) 3 tx - 8 di ( - ) 4 tx+ 5 di (+) 5 gnd 6 gnd www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 637 driver version : version date description v1. 0 0 aug / 31 /20 11 driver r eleased. www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 638 sstc ssd series supported s eries: sstc ssd series hmi setting: parameters recommend ed option s notes plc type sstc ssd series plc i/f rs232 rs232/ rs485 2w baud rate 19200 9600~115200 data b its 8 8 parity none none, odd stop bits 1 1 plc s t a . n o. 1 1 ~32 x series does not support rs - 485 2w communication. device a ddress: bit/word device type format range memo w id dddd d 0 ~ 99999 w id_30 dddd d 30 use unicode w id_35000 ddd dd 35000 string w id_35001 dddd d 35001 string i d address list: id no. data length data type write / read decimal place* 1 byt 2 udec y es/yes 1 30 byt4 hex no /yes hex 36 byt4 sdec y es/yes 0.0001 38 byt4 udec y es/yes 0.0001 39 byt4 sdec y es/yes 0.0001 40 byt4 sdec no /yes 0.0001 41 byt4 sdec no /yes 0.0001 43 byt2 udec y es/yes 1 47 byt4 sdec y es/yes 1 48 byt4 sdec y es/yes 1 www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 639 id no. data length data type write / read decimal place* 49 byt4 sdec y es/yes 1 50 byt4 sdec y es/yes 1 51 byt4 sdec y es/yes 1 53 byt4 sdec y es/yes 1 55 byt2 udec y es/yes 1 57 byt4 udec y es/yes 1 80 byt2 sdec y es/yes 0.1 82 byt 2 udec y es/yes 0.1 83 byt2 sdec y es/yes 0.1 84 byt2 sdec no /yes 0.1 85 byt2 udec y es/yes 1 100 byt2 udec y es/yes 1 101 byt2 udec y es/yes 0.1 102 byt2 udec y es/yes 0.1 103 byt4 sdec y es/yes 1 104 byt2 udec y es/yes 1 109 byt4 udec y es/yes 0.001 110 byt4 udec no /yes 0.001 111 byt4 udec y es/yes 0.001 112 byt4 udec no /yes 0.001 113 byt4 udec y es/yes 0.0001 116 byt4 udec y es/yes 1 124 byt4 sdec y es/yes 0.0001 125 byt4 sdec y es/yes 0.0001 126 byt2 sdec y es/yes 0.1 136 byt4 sdec y es/yes 1 137 byt 4 sdec y es/yes 1 147 byt2 hex y es/yes hex 150 byt4 sdec y es/yes 1 153 byt4 sdec y es/yes 1 154 but2 hex y es/yes hex 157 byt4 sdec y es/yes 0.0001 159 byt4 udec y es/yes 1 173 byt4 sdec y es/yes 1 www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 640 id no. data length data type write / read decimal place* 193 byt2 udec y es/yes 1 209 byt4 udec y es/yes 0.0001 2 10 byt4 udec y es/yes 0.0001 211 byt2 udec y es/yes 0.1 212 byt2 udec y es/yes 0.1 222 byt4 sdec y es/yes 1 225 byt2 hex y es/yes hex 228 byt4 udec y es/yes 1 230 byt4 udec y es/yes 1 268 byt4 udec y es/yes 1 278 byt4 udec y es/yes 1 32768 byt2 udec y es/ye s 0.1 32769 byt4 udec y es/yes 0.001 32770 byt4 udec y es/yes 0.001 32771 byt2 udec y es/yes 0.1 32772 byt4 udec y es/yes 0.0001 32773 byt4 hex y es/yes hex 32774 byt2 udec y es/yes 0.1 32775 byt2 udec y es/yes 1 32776 byt2 udec y es/yes 1 32777 byt2 sdec y es/yes 0.1 32778 byt4 sdec y es/yes 0.0001 32779 byt4 sdec y es/yes 0.0001 32780 byt4 udec y es/yes 0.1 32781 byt4 udec y es/yes 0.1 32782 byt4 udec y es/yes 0.1 32783 byt2 udec y es/yes 1 32784 byt4 sdec y es/yes 1 32785 byt2 udec y es/yes 1 32786 byt4 sdec y es/yes 1 32787 byt4 udec y es/yes 1 32788 byt4 sdec y es/yes 1 32789 byt4 udec y es/yes 1 32790 byt4 sdec y es/yes 1 www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 641 id no. data length data type write / read decimal place* 32791 byt4 udec y es/yes 1 32792 byt4 sdec y es/yes 1 32793 byt4 udec y es/yes 1 32794 byt4 sdec y es/yes 1 32797 byt4 hex no/ yes h ex 32798 byt4 hex no / no hex 32799 byt4 hex no / no hex 32800 byt4 hex y es/yes hex 32801 byt4 hex y es/yes hex 32802 byt4 hex y es/yes hex 32803 byt4 hex y es/yes hex 32804 byt4 hex y es/yes hex 32805 byt4 hex y es/yes hex 32806 byt4 udec y es/yes 1 32807 byt4 udec y es/yes 1 32808 byt4 udec y es/yes 1 32809 byt4 udec y es/yes 1 32836 byt2 udec no /yes 1 32845 byt2 udec y es/yes 1 32846 byt2 sdec y es/yes 1 32847 byt2 sdec y es/yes 1 32848 byt2 udec y es/yes 1 32849 byt2 sdec y es/yes 1 32850 byt2 sdec y es /yes 1 32851 byt2 sdec y es/yes 1 32852 byt2 sdec y es/yes 1 32853 byt2 sdec y es/yes 1 32854 byt2 sdec y es/yes 1 32865 byt2 udec y es/yes 1 32866 byt2 udec y es/yes 1 32867 byt2 udec y es/yes 1 32868 byt2 udec y es/yes 1 32874 byt2 udec y es/yes 1 32875 byt2 udec y es/yes 1 www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 642 id no. data length data type write / read decimal place* 32876 byt2 udec y es/yes 1 32877 byt2 udec y es/yes 1 32880 byt2 udec y es/yes 1 32881 byt2 udec y es/yes 1 32882 byt2 udec y es/yes 1 32883 byt2 udec y es/yes 1 32891 byt2 udec y es/yes 1 32892 byt4 udec y es/yes 1 32893 byt4 udec y e s/yes 1 32922 byt2 udec y es/yes 1 32925 byt2 hex y es/yes hex 32926 byt2 hex y es/yes hex 32927 byt2 hex y es/yes hex 32928 byt2 udec y es/yes 0.1 32929 byt2 udec y es/yes 0.1 32934 byt2 udec y es/yes 1 32935 byt2 udec y es/yes 0.1 32936 byt4 hex y es/yes hex 32940 byt4 sdec y es/yes 1 32947 byt4 udec y es/yes 1 32952 byt4 udec y es/yes 1 32953 byt2 hex y es/yes hex 32956 byt2 udec y es/yes 1 32958 byt2 udec y es/yes 1 32959 byt2 udec y es/yes 1 32964 byt2 udec y es/yes 1 32966 byt2 sdec y es/yes 1 32967 byt2 udec y es/yes 1 32968 byt2 udec y es/yes 0.1 32978 byt2 udec y es/yes 1 32979 byt2 udec y es/yes 1 32980 byt2 udec y es/yes 1 32981 byt2 udec y es/yes 1 32992 byt2 udec y es/yes 0.1 www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 643 id no. data length data type write / read decimal place* 32993 byt2 udec y es/yes 0.1 33700 byt2 udec y es/yes 1 33701 byt2 ud ec y es/yes 1 33702 byt2 udec y es/yes 1 33703 byt2 udec y es/yes 1 33704 byt2 udec y es/yes 1 33705 byt2 udec y es/yes 1 33706 byt2 udec y es/yes 1 33707 byt2 udec y es/yes 1 33708 byt2 udec y es/yes 1 33709 byt2 udec y es/yes 1 33710 byt2 udec y es/yes 1 33711 byt2 udec y es/yes 1 33712 byt2 udec y es/yes 1 3 3713 byt2 udec y es/yes 1 3 3714 byt2 udec y es/yes 1 33721 byt2 udec y es/yes 1 33722 byt2 udec y es/yes 1 3372 4 byt2 udec y es/yes 1 3372 5 byt2 udec y es/yes 1 33729 byt2 udec y es/yes 1 33730 byt2 u dec y es/yes 1 33731 byt2 udec y es/yes 1 33732 byt2 udec no /yes 1 33800 byt2 udec y es/yes 1 33801 byt2 udec y es/yes 1 33802 byt2 udec y es/yes 1 33803 byt2 udec y es/yes 1 33804 byt2 udec y es/yes 1 33805 byt2 udec y es/yes 1 33806 byt2 udec y es/yes 1 33807 byt2 udec y es/yes 1 33808 byt2 udec y es/yes 1 33809 byt2 udec y es/yes 1 www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 6 44 id no. data length data type write / read decimal place* 33810 byt2 udec y es/yes 1 33811 byt2 udec y es/yes 1 33812 byt2 udec y es/yes 1 33813 byt2 udec y es/yes 1 33814 byt2 udec y es/yes 1 33815 byt2 udec y es/yes 1 33816 byt2 udec y es/yes 1 33817 byt2 udec y es/yes 1 33818 byt2 udec y es/yes 1 33819 byt2 udec y es/yes 1 33820 byt2 udec y es/yes 1 33839 byt2 udec y es/yes 1 33840 byt2 udec y es/yes 1 33859 byt2 udec y es/yes 1 33860 byt2 udec y es/yes 1 33869 byt2 udec y es/yes 1 33880 byt2 udec y es/yes 1 33889 byt2 udec y es/yes 1 338 90 byt2 udec y es/yes 1 338 99 byt2 udec y es/yes 1 34000 byt2 udec y es/yes 1 3 4001 byt2 udec y es/yes 1 3 4002 byt2 udec y es/yes 1 3 4003 byt2 udec y es/yes 1 3 4004 byt2 udec y es/yes 1 3 4005 byt 2 udec y es/yes 1 3 4006 byt2 udec y es/yes 1 3 4007 byt2 udec y es/yes 1 3 4008 byt2 udec y es/yes 1 3 4009 byt2 udec y es/yes 1 3 4010 byt2 udec y es/yes 1 3 4011 byt2 udec y es/yes 1 3 4012 byt2 udec y es/yes 1 3 4013 byt2 udec y es/yes 1 www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 645 id no. data length data type write / read decimal place* 3 4014 byt2 udec y es/ye s 1 340 15 byt2 udec y es/yes 1 340 16 byt2 udec y es/yes 1 340 17 byt2 udec y es/yes 1 340 18 byt2 udec y es/yes 1 340 19 byt2 udec y es/yes 1 34023 byt2 udec y es/yes 1 34025 byt2 udec y es/yes 1 34042 byt2 udec y es/yes 1 34043 byt2 udec y es/yes 0.01 34044 byt2 udec y es/yes 0.01 34045 byt2 udec y es/yes 0.01 34046 byt2 udec y es/yes 0.01 34047 byt2 udec y es/yes 0.01 34048 byt2 udec y es/yes 0.01 34049 byt2 udec y es/yes 0.01 34050 byt2 udec y es/yes 0.1 34051 byt2 udec y es/yes 0.01 34052 byt2 udec y es/ye s 0.1 34053 byt2 udec y es/yes 1 34054 byt2 udec y es/yes 0.1 34055 byt2 udec y es/yes 0.1 34056 byt2 udec y es/yes 1 34070 byt2 udec y es/yes 1 34148 byt2 udec y es/yes 0.001 34149 byt2 udec y es/yes 0.1 34164 byt2 udec y es/yes 0.01 34167 byt2 udec y es/ yes 0.01 34177 byt2 udec y es/yes 1 34178 byt2 udec y es/yes 1 34179 byt2 udec y es/yes 1 34180 byt2 udec y es/yes 1 34182 byt4 sdec y es/yes 1 35000 /* depends on text */ 0 asci no /yes ascii www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 646 id no. data length data type write / read decimal place* 35001 /* depends on text */ 0 asci no/yes ascii 35002 byt4 he x no/yes 1 35003 byt2 hex no/yes hex 35004 byt2 udec no/yes 0.1 35005 byt2 udec no/yes 0.1 35006 byt2 udec no/yes 0.1 35007 byt2 udec no/yes 0.1 35008 byt2 udec no/yes 0.1 35009 byt2 udec no/yes 0.1 35010 byt2 udec no/yes 0.1 35011 byt2 udec no/ye s 1 36000 byt2 udec no/yes 1 36001 byt2 udec no/yes 1 36002 byt4 sdec no/yes 1 36003 byt4 sdec no/yes 1 36004 byt4 udec no/yes 1 36005 byt4 udec no/yes 1 36006 byt2 udec no/yes 1 36007 byt2 udec no/yes 1 36008 byt2 udec no/yes 1 36009 byt2 udec n o/yes 1 36010 byt2 udec no/yes 1 36011 byt2 udec no/yes 1 36012 byt4 udec no/yes 1 36013 byt4 udec no/yes 1 36019 byt2 udec y es/yes 1 36020 byt2 udec y es/yes 1 36021 byt2 udec y es/yes 1 36022 byt2 udec y es/yes 1 36023 byt2 udec y es/yes 1 36100 by t4 udec y es/yes 1 36101 byt4 udec y es/yes 1 36102 byt4 udec y es/yes 1 36103 byt4 udec y es/yes 1 www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 647 id no. data length data type write / read decimal place* 36104 byt4 udec y es/yes 1 *note: if the decimal place of id is 0.0001, please set [right of decimal pt.] of the object to 4 . wiring d iagram: the follo wing represents the view of hmi & plc. rs - 232 e mt 3 000 series com1 rs232 9p d - sub fem ale com 3 rs232 9p d - sub fem ale x5 port rs232 9p d - sub male 2 rx 8 rx 2 t x 3 tx 7 tx 3 r x 5 gnd 5 gnd 5 gnd mt6000 /8000 series except mt6050i/mt8050i com1 rs 232 9p d - sub fem ale com2 rs232 9p d - sub fem ale com3 rs232 9p d - sub m ale x5 port rs232 9p d - sub male 2 rx 6 rx 8 rx 2 t x 3 tx 4 tx 7 tx 3 r x 5 gnd 5 gnd 5 gnd 5 gnd www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 648 mt6050i/mt8050i com1 rs232 9p d - sub fem ale x5 port rs232 9p d - sub male 9 r x 2 t x 6 tx 3 r x 5 gnd 5 gnd the following represents the view of hmi & plc. rs485 2w e mt 3 000 series com1 rs485 2 w 9p d - sub m ale com 3 rs485 2 w 9p d - sub m ale x5 port rs485 2w 9p d - sub male 1 rx - 6 data - 4 rs485 - 2 rx+ 9 data+ 1 rs485+ 5 gnd 5 gnd 5 gnd mt6000 /8000 series except mt6050i/mt8050i com1 rs485 2 w 9p d - sub m ale com 3 rs485 2 w 9p d - sub m ale x5 port rs485 2w 9p d - sub male 1 rx - 6 data - 4 rs485 - 2 rx+ 9 data+ 1 rs485+ 5 gnd 5 gnd 5 gnd mt6050i/mt8050i com 1 rs485 2 w 9p d - sub fem ale com 3 rs485 2 w 9p d - sub fem ale x5 port rs485 2w 9p d - sub male 1 rx - 7 data - 4 rs485 - 2 rx+ 8 data+ 1 rs485+ 5 gnd 5 gnd 5 gnd www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 649 driver version : version date description v1.0 0 mar / 27 /2012 driver released. v1.10 jul/ 20 /2012 the newly supported software ssts_pas_v2. 3 supports id address. www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 650 techsoft intelligent servo supported s eries: intelligent servo supports idm640, idm240. website: http://www.techsoftmotion.com hmi setting: parameters recommend ed option s notes plc type intelligent servo plc i/f rs232 baud rate 9600 9600 ~115200 data b its 8 7 or 8 parity none even, odd, none stop b its 1 1 or 2 plc s t a . n o. 1 device a ddress: bit/word device t ype forma t range memo w register _ 32bit hhhh 0 ~ 270f 32bit signed d w register_h hhhh 0 ~ 270f 32bit hex w upd hhhhh 0 ~ 1869f send udp command w stop hhhhh 0 ~ 1869f send stop command wiring d iagram: the following represents the view of hmi & plc. e mt 3 000 ser ies com1 rs232 9p d - sub fem ale com 3 rs232 9p d - sub fem ale servo rs232 d - sub m ale 2 rx 8 rx 2 t d 3 tx 7 tx 3 r d 5 gnd 5 gnd 5 gnd www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 651 mt6000 /8000 series except mt6050i/mt8050i com1 rs232 9p d - sub fem ale com2 rs232 9p d - sub fem ale com3 rs232 9p d - sub m ale servo rs232 d - sub m ale 2 rx 6 rx 8 rx 2 t d 3 tx 4 tx 7 tx 3 r d 5 gnd 5 gnd 5 gnd 5 gnd mt6050i/mt8050i com1 rs232 9p d - sub fem ale servo rs232 d - sub m ale 9 rx 2 t d 6 tx 3 r d 5 gnd 5 gnd driver version : version dat e description v1.00 nov/06/2009 driver released . www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 652 t eco inverter supported s eries: teco inverter series, 7300cv model . hmi setting: parameters recommend ed option s notes plc type teco inverter plc i/f rs 232 rs232/rs485 baud rate 38400 data b its 8 parity none stop b its 1 plc s t a . n o. 1 device a ddress: bit/word device t ype format range memo b 0x ddddd 1 ~ 65535 output b it b 1x ddddd 1 ~ 65535 input b it (read only) b 3x_bit ddddddd 100 ~ 6553515 input register b it (read only) b 4x_bi t ddddddd 100 ~ 6553515 output register b it b 6x_bit ddddddd 100 ~ 6553515 b 0x (0x0f) ddddd 1 ~ 65535 write multiple coils w 3x ddddd 1 ~ 65535 input register (read only) w 4x ddddd 1 ~ 65535 output register dw 5x ddddd 1 ~ 65535 4x d ouble w ord s wap w 6x ddddd 1 ~ 65535 4x s ingle w ord w rite www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 653 wiring d iagram: the following represents the view of hmi & plc. 9p d - sub to 9p d - sub: e mt 3 000 series com1 rs232 9p d - sub fem ale rs232 9p d - sub male 2 rx 2 t x 3 tx 3 r x 5 gnd 5 g nd 7 rts 7 vcc www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 654 mt6000 /8000 series except mt6050i/mt8050i com1 rs232 9p d - sub fem ale rs232 9p d - sub male 2 rx 2 t x 3 tx 3 r x 5 gnd 5 gnd 7 rts 7 vcc driver version : version date description v1.00 jul/27/2009 driver relea sed . www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 655 teco tp02 series supported s eries: taian tp02 series website: http://www.taian - technology.com hmi setting: parameters recommend ed option s notes plc type teco tp02 series plc i/f rs485 4w/2w rs485 4w/2w mmi 422 port: 4w; rs485 terminals: 2w baud rate 19200 9600, 19200, 38400 data b its 7 7, 8 parity even even, odd, none stop b its 2 1, 2 plc s t a . n o. 1 0 - 255 plc setting: rs422 port: ws041=120, ws042=1; rs485 terminals: ws044=120, ws045=1. device a ddress: bit/word device t ype format range memo b x ddd 1 ~ 384 input relay b y ddd 1 ~ 384 output relay b c dddd 1 ~ 2048 auxiliary relay w x ddd 1 ~ 369 input register (must be 1 or a multiple of plus 1) w y ddd 1 ~ 369 output register (m ust be 1 or a multiple of plus 1) w v dddd 1 ~ 1024 auxiliary register w d dddd 1 ~ 2048 auxiliary register w ws ddd 1 ~ 128 system register w c dddd 1 ~ 2033 auxiliary relay register (must be 1 or a multiple of plus 1) w wc ddd 1 ~ 912 constant regi ster www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 656 wiring d iagram: the following represents the view of hmi & plc. tp02 series mmi rs422 port : 9p d - sub to 9p d - sub e mt 3 000 series com1 rs485 4 w 9p d - sub m ale rs485 4w 9p d - sub male 1 rx - 8 tx - 2 r x + 3 tx+ 3 tx - 7 rx - 4 tx+ 2 rx+ 5 gnd mt6000 /8000 series except mt6050i/mt8050i com1 rs485 4 w 9p d - sub m ale rs485 4w 9p d - sub male 1 rx - 8 tx - 2 r x + 3 tx+ 3 tx - 7 rx - 4 tx+ 2 rx+ 5 gnd mt6050i/mt8050i com1 rs485 4 w 9p d - sub fem ale rs485 4w 9p d - sub male 1 rx - 8 tx - 2 r x + 3 tx+ 3 tx - 7 rx - 4 tx+ 2 rx+ 5 gnd www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 657 the following represents the view of hmi & plc. tp02 series rs485 terminal : 9p d - sub to 9p d - sub e mt 3 000 series com1 rs485 2 w 9p d - sub m ale com 3 rs485 2 w 9p d - sub m ale rs 485 2w terminal 1 rx - 6 data - t /r - 2 rx+ 9 data+ t/r+ 5 gnd 5 gnd mt6000 /8000 series except mt6050i/mt8050i com1 rs485 2 w 9p d - sub m ale com 3 rs485 2 w 9p d - sub m ale rs 485 2w terminal 1 rx - 6 data - t /r - 2 rx+ 9 data+ t/r+ 5 gnd 5 gnd mt6050i/mt8050i com1 rs485 2 w 9p d - sub fem ale com 3 rs485 2 w 9p d - sub fem ale rs 485 2w terminal 1 rx - 7 data - t /r - 2 rx+ 8 data+ t/r+ 5 gnd 5 gnd driver version : version date description v1. 1 0 jan /2 5 /20 10 www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 658 teco tp03 series supported s eries: teco ( taian tp03 ) series plc . website: http://www.teco.com.tw/sa/en/ hmi setting: parameters recommend ed option s notes plc type teco tp03 series plc i/f rs485 4 w baud rate 19200 9600, 19200 da ta b its 8 8 parity none even, odd, none stop b its 2 1 plc s t a . n o. 1 1 - 31 device a ddress: bit/word device t ype format range memo b c dddd 0 ~ 9999 b m dddd 0 ~ 9999 b s dddd 0 ~ 9999 b t dddd 0 ~ 9999 b x ooo 0 ~ 377 b y ooo 0 ~ 377 w d dddd 0 ~ 9999 w v dddd 0 ~ 9999 w z dddd 0 ~ 9999 w t_curent dddd 0 ~ 9999 w c_curent dddd 0 ~ 9999 w t_preset dddd 0 ~ 9999 w c_preset dddd 0 ~ 9999 www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 659 wiring d iagram: the following represents the view of hmi & plc. e mt 3 000 series com1 rs485 4 w 9p d - sub m ale rs485 4w 8 p mini - din male 1 rx - 4 t x - 2 r x + 7 tx+ 3 tx - 1 rx - 4 tx+ 2 rx+ 5 gnd 3 gnd mt6000 /8000 series except mt6050i/mt8050i com1 rs485 4 w 9p d - sub m ale rs485 4w 8 p mini - din male 1 rx - 4 t x - 2 r x + 7 tx+ 3 tx - 1 rx - 4 tx+ 2 rx+ 5 gnd 3 gnd mt6050i/mt8050i com1 rs485 4 w 9p d - sub fem ale rs485 4w 8 p mini - din male 1 rx - 4 t x - 2 r x + 7 tx+ 3 tx - 1 rx - 4 tx+ 2 rx+ 5 gnd 3 gnd www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 660 driver version : version date descripti on v1. 1 0 nov/13/2009 www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 661 tinhao website: www.chinastrand.com hmi setting: parameters recommend ed option s notes plc type tinhao plc i/f rs485 2w baud rate 19200 data b its 8 parity none stop b its 1 plc s t a . n o. 1 device a ddress: bit/word device t ype format range memo w commend1 ddd 0 ~ 255 w commend2 ddd 0 ~ 255 w commend3 ddd 0 ~ 255 w commend4 ddd 0 ~ 255 w commend5 ddd 0 ~ 255 w commend6 ddd 0 ~ 255 w commend7 ddd 0 ~ 255 w commend8 ddd 0 ~ 255 w commend9 ddd 0 ~ 255 w commend1 0 ddd 0 ~ 255 w commend1 1 ddd 0 ~ 255 w commend1 2 ddd 0 ~ 255 w commend1 3 ddd 0 ~ 255 w commend1 4 ddd 0 ~ 255 w commend1 5 ddd 0 ~ 255 w commend1 6 ddd 0 ~ 255 w commend1 7 ddd 0 ~ 255 w commend1 8 ddd 0 ~ 255 www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 662 bit/word device t ype format range memo w commend1 9 ddd 0 ~ 255 w commend20 ddd 0 ~ 255 w commend21 ddd 0 ~ 255 w commend22 ddd 0 ~ 255 wiring d iagram: the following represents the view of hmi & plc. e mt 3 000 series com1 rs485 2 w 9p d - sub m ale com 3 rs485 2 w 9p d - sub m ale rs 485 terminal 1 rx - 6 data - d - 2 rx+ 9 data+ d+ 5 gnd 5 gnd mt6000 /8000 series except mt6050i/mt8050i com1 rs485 2 w 9p d - sub m ale com 3 rs485 2 w 9p d - sub m ale rs 485 terminal 1 rx - 6 data - d - 2 rx+ 9 data+ d+ 5 gnd 5 gnd www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 663 mt6050i/mt8050i com1 rs485 2 w 9p d - sub fem ale com 3 rs485 2 w 9p d - sub fem ale rs 485 terminal 1 rx - 7 data - d - 2 rx+ 8 data+ d+ 5 gnd 5 gnd driver version: version date description v1.00 oct/14 /2011 driver released . www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 664 toptek to pvert supported s eries: topvert g1/h1/p1 series . website: http://www.toptek.biz/ hmi setting: parameters recommend ed option s notes plc type toptek topvert plc i/f rs485 2w baud rate 9600 data b its 7 par ity none stop b its 2 plc s t a . n o. 1 online s imulator yes broadcast command yes extend address mode yes broadcast station no. 0 plc setting: communication mode pr 7 - 15 = 0 (7, n, 2 ascii) device a ddress: bit/word device t ype format range memo b pr_bit ddddddd 0 ~ 6553515 g=groups, f=function no. dd=0~15 bit no. w pr ddddd 0 ~ 65535 g=groups, f=function no. www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 665 note : max.read - command size (words) : 16 max.write - command size (words) : 1 for g1/h1/p1 series inverter, if standard parameter address is in decimal= 100*g+f: g=group (parameter group code0~9); f=function no. (parameter number 0~99) for example: pr5 - 20 (decimal dec.) parameter address is expressed as 100*5+20=520. parameter (prx - xx) address (decimal) 0 - 00 0*100+0=0 0 - 14 0*100+14=14 1 - 00 1*100+0=100 wiring d iagram: the following represents the view of hmi & plc. e mt 3 000 series com1 rs485 2 w 9p d - sub m ale com 3 rs485 2 w 9p d - sub m ale rs485 2w terminal 1 rx - 6 data - sg - 2 rx+ 9 data+ sg+ 5 gnd 5 gnd mt6000 /8000 series ex cept mt6050i/mt8050i com1 rs485 2 w 9p d - sub m ale com 3 rs485 2 w 9p d - sub m ale rs485 2w terminal 1 rx - 6 data - sg - 2 rx+ 9 data+ sg+ 5 gnd 5 gnd www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 666 mt6050i/mt8050i com1 rs485 2 w 9p d - sub fem ale com 3 rs485 2 w 9p d - sub fem ale rs485 2w terminal 1 rx - 7 data - sg - 2 rx+ 8 data+ sg+ 5 gnd 5 gnd driver version: version date description v1.00 dec/ 08 /2010 driver released . www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 667 toshiba t series supported s eries: toshiba t series , s2e . website: http://www. tic.toshiba. com hmi setting: parameters recommend ed option s notes plc type toshiba t series plc i/f rs 232 rs232/rs485 in accordance with plc port baud rate 9600 9600, 19200 , 38400, 57600, 115200 data b its 8 7, 8 parity odd even, odd, no ne stop b its 1 1 , 2 plc s t a . n o. 0 0 - 255 must be same as the plc setting online s imulator yes extend address mode yes plc setting: communication mode must set plc node id device a ddress: bit/word device t ype format range memo b x ddddh 0 ~ 4095f input bit b y ddddh 0 ~ 4095f output bit b r ddddh 0 ~ 8191f auxiliary bit b s ddddh 0 ~ 4095f special bit b l ddddh 0 ~ 4095f b z ddddh 0 ~ 8191f w t ddd 0 ~ 999 timer register w c ddd 0 ~ 511 counter register w d dddd 0 ~ 8191 data memory www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 668 bit/word device t ype format range memo w s w ddd 0 ~ 255 special register w xw ddd 0 ~ 255 input register w yw ddd 0 ~ 255 output register w rw ddd 0 ~ 999 auxiliary register w lw ddd 0 ~ 255 w w dddd 0 ~ 1023 w f dddd 0 ~ 8191 wiring d iagram: the following represents the view of hmi & p lc. toshiba t1 prg rs232 : 9p d - sub to 8 p m ini - din e mt 3 000 series com1 rs232 9p d - sub fem ale com 3 rs232 9p d - sub fem ale rs232 8 p m ini - din male 2 rx 8 rx 6 t xd 3 tx 7 tx 8 r xd 5 gnd 5 gnd 5 gnd 4 rts circuit 7 cts mt6000 /8000 series except mt6050i/mt8050i com1 rs232 9p d - sub fem ale com2 rs232 9p d - sub fem ale com3 rs232 9p d - sub m ale rs232 8 p m ini - din male 2 rx 6 rx 8 rx 6 t xd 3 tx 4 tx 7 tx 8 r xd 5 gnd 5 gnd 5 gnd 5 gnd 4 rts circuit 7 cts www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 669 mt6050i/mt8050i com1 rs2 32 9p d - sub fem ale rs232 8 p m ini - din male 9 rx 6 t xd 6 tx 8 r xd 5 gnd 5 gnd 4 rts circuit 7 cts the following represents the view of hmi & plc. toshiba t2 prg rs232 : 9p d - sub to 9 p d - sub e mt 3 000 series com1 rs232 9p d - sub fem ale c om 3 rs232 9p d - sub fem ale rs232 9 p d - sub male 2 rx 8 rx 3 t xd 3 tx 7 tx 2 r xd 5 gnd 5 gnd 5 gnd 7 rts circuit 8 cts mt6000 /8000 series except mt6050i/mt8050i com1 rs232 9p d - sub fem ale com2 rs232 9p d - sub fem ale com3 rs232 9p d - sub m ale rs232 9 p d - sub male 2 rx 6 rx 8 rx 3 t xd 3 tx 4 tx 7 tx 2 r xd 5 gnd 5 gnd 5 gnd 5 gnd 7 rts circuit 8 cts www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 670 mt6050i/mt8050i com1 rs232 9p d - sub fem ale rs232 9 p d - sub male 9 rx 3 t xd 6 tx 2 r xd 5 gnd 5 gnd 7 rts circuit 8 cts the following represents the view of hmi & plc. toshiba t2 link port rs 485 4w : 9p d - sub to 15 p d - sub e mt 3 000 series com1 rs485 4 w 9p d - sub m ale rs 485 4w 15 p d - sub male 1 rx - 11 t xb 2 r x + 3 txa 3 tx - 10 rxb 4 tx+ 2 rxa 5 gn d 7 s g 5 rtsa circuit 4 ctsa 13 rtsb circuit 12 ctsb www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 671 mt6000 /8000 series except mt6050i/mt8050i com1 rs485 4 w 9p d - sub m ale rs 485 4w 15 p d - sub male 1 rx - 11 t xb 2 r x + 3 txa 3 tx - 10 rxb 4 tx+ 2 rxa 5 gnd 7 s g 5 rtsa circuit 4 ctsa 13 rtsb circuit 12 ctsb mt6050i/mt8050i com1 rs485 4 w 9p d - sub fem ale rs 485 4w 15 p d - sub male 1 rx - 11 t xb 2 r x + 3 txa 3 tx - 10 rxb 4 tx+ 2 rxa 5 gnd 7 s g 5 rtsa circuit 4 ctsa 13 rtsb circuit 12 cts b driver version : version date description v1. 2 0 may / 13 /20 11 toshiba t series driver can now correctly read and write l , lw , f address types. www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 672 toshiba vf - s11 supported s eries: toshiba invertor protocol (ascii code) . hmi setting: parame ters recommend ed option s notes plc type toshiba vf - s11 plc i/f rs485 2 w rs422, rs485 baud rate 9600 9600, 19200 data b its 8 7 or 8 parity even even, odd, none stop b its 1 1 or 2 plc s t a . n o. 0 0 - 99 online s imulator yes extend address mode y es broadcast command yes device a ddress: bit/word device t ype format range memo b c md. no b hhhhdd 0 ~ 270f15 w cm d . no hhh h 0 ~ ffff parameters and data memory wiring d iagram: note : before connecting with vf - s11, make sure the sw1 of both sides are in the correct position. (sw1: w iring method selector switch) www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 673 rs - 485 the following represents the view of hmi & plc. e mt 3 000 series com1 rs485 2 w 9p d - sub m ale com 3 rs485 2 w 9p d - sub m ale rs 485 2w 8 p rj45 male 1 rx - 6 data - 5 data - 2 rx+ 9 data+ 4 data+ 5 gnd 5 gnd 8 gnd mt6000 /8000 series except mt6050i/mt8050i com1 rs485 2 w 9p d - sub m ale com 3 rs485 2 w 9p d - sub m ale rs 485 2w 8 p rj45 male 1 rx - 6 data - 5 data - 2 rx+ 9 data+ 4 data+ 5 gnd 5 gnd 8 gnd www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 674 mt6050i/mt8050i co m1 rs485 2 w 9p d - sub fem ale com 3 rs485 2 w 9p d - sub fem ale rs 485 2w 8 p rj45 male 1 rx - 7 data - 5 data - 2 rx+ 8 data+ 4 data+ 5 gnd 5 gnd 8 gnd driver version : version date description v1.20 aug/31/2009 www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 675 toshiba machine provisor tc200 sup ported s eries: toshiba machine co., japan website: http://www.toshiba - machine.co.jp hmi setting: parameters recommend ed option s notes plc type toshiba machine provisor tc200 plc i/f rs 232 rs232 in acco rdance with plc port baud rate 9600 9600, 19200 da ta b its 8 7, 8 parity none even, odd, none stop b its 1 1 , 2 device a ddress: bit/word device t ype format range memo b r_ b it hhhh 0 ~ fff f h : bit no.(0~f) b x_ b it hhhh 0 ~ fff f h : bit no.(0~f) b y_ b it hhhh 0 ~ fff f h : bit no.(0~f) b l_ b it hhhh 0 ~ fff f h : bit no.(0~f) b g_bit hhhh 0 ~ fff f h : bit no.(0~f) b h_bit hhhh 0 ~ fff f h : bit no.(0~f) b t_bit hhhh 0 ~ fff f h : bit no.(0~f) b c_bit hhhh 0 ~ fff f h : bit no.(0~f) b s_bit hhhh 0 ~ fff f h : bit no.(0~f) b e_bit hhhh 0 ~ fff f h : bit no.(0~f) w p hhh 0 ~ fff w v hhh 0 ~ fff w x hhh 0 ~ fff w y hhh 0 ~ fff w d hhh 0 ~ fff w r hhh 0 ~ fff w l hhh 0 ~ fff w b hhh 0 ~ fff w g hhh 0 ~ fff www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 676 bit/word device t ype format range memo w h hhh 0 ~ fff w t hhh 0 ~ f ff w c hhh 0 ~ fff w s hhh 0 ~ fff w e hhh 0 ~ fff wiring d iagram: the following represents the view of hmi & plc. e mt 3 000 series com1 rs232 9p d - sub fem ale com 3 rs232 9p d - sub fem ale tc mini series rs232 9 p d - sub male 2 rx 8 rx 2 t xd 3 tx 7 t x 3 r xd 5 gnd 5 gnd 5 gnd 7 rts circuit 9 cts mt6000 /8000 series except mt6050i/mt8050i com1 rs232 9p d - sub fem ale com2 rs232 9p d - sub fem ale com3 rs232 9p d - sub m ale tc mini series rs232 9 p d - sub male 2 rx 6 rx 8 rx 2 t xd 3 tx 4 tx 7 tx 3 r xd 5 gnd 5 gnd 5 gnd 5 gnd 7 rts circuit 9 cts www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 677 mt6050i/mt8050i com1 rs232 9p d - sub fem ale tc mini series rs232 9 p d - sub male 9 rx 2 t xd 6 tx 3 r xd 5 gnd 5 gnd 7 rts circuit 9 cts driver version : version da te description v1 .10 aug/17/2012 added register: b,g,h,t,c,s,f. www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 678 trio modbus rtu, tcp/ip website : http://www.triomotion.com hmi setting: parameters recommend ed option s notes plc type trio modbus rtu, tcp/ip plc i/f rs 485 rs 232/rs485 /ethernet baud rate 9600 9600 ~ 115200 data b its 8 7, 8 parity even even, odd, none stop b its 1 1 , 2 p ort n o. 502 plc s t a . n o. 1 0 - 255 online s imulator yes broadcast command yes extend address mode yes plc setti ng: communication mode modbus rtu protocol plc mode 4 ( 16bit signed integer ) device a ddress: bit/word device t ype format range memo b vr_bit dddddd 0 ~ 102315 b table_bit ddddddd 0 ~ 3199915 w vr dddd 0 ~ 1023 w table ddddd 0 ~ 31999 www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 679 wiring d iagram: the following represents the view of hmi & plc. 3 trio : rs232 e mt 3 000 series com1 rs232 9p d - sub fem ale com 3 rs232 9p d - sub fem ale rs232 9p d - sub male 2 rx 8 rx t x d 3 tx 7 tx r x d 5 gnd 5 gnd gnd rts circuit cts mt6000 / 8000 series except mt6050i/mt8050i com1 rs232 9p d - sub fem ale com2 rs232 9p d - sub fem ale com3 rs232 9p d - sub m ale rs232 9p d - sub male 2 rx 6 rx 8 rx t x d 3 tx 4 tx 7 tx r x d 5 gnd 5 gnd 5 gnd gnd rts circuit cts mt6050i/mt8050i com1 rs 232 9p d - sub fem ale rs232 9p d - sub male 9 rx t x d 6 tx r x d 5 gnd gnd rts circuit cts www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 680 the following represents the view of hmi & plc. trio : rs485 4w e mt 3 000 series com1 rs485 4 w 9p d - sub m ale rs 485 4w 9p d - sub male 1 rx - tx - 2 r x + tx+ 3 tx - rx - 4 tx+ rx+ 5 gnd gnd mt6000 /8000 series except mt6050i/mt8050i com1 rs485 4 w 9p d - sub m ale rs 485 4w 9p d - sub male 1 rx - tx - 2 r x + tx+ 3 tx - rx - 4 tx+ rx+ 5 gnd gnd mt6050i/mt8050i com1 rs485 4 w 9p d - sub fem ale rs 485 4w 9p d - sub male 1 rx - tx - 2 r x + tx+ 3 tx - rx - 4 tx+ rx+ 5 gnd gnd www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 681 the following represents the view of hmi & plc. trio : rs485 2w e mt 3 000 series com1 rs485 2 w 9p d - sub m ale com 3 rs485 2 w 9p d - sub m ale rs 485 2w 9p d - sub male 1 rx - 6 data - d - 2 rx+ 9 data+ d+ 5 gnd 5 gnd gnd mt6000 /8000 series except mt6050i/mt8050i com1 rs485 2 w 9p d - sub m ale com 3 rs485 2 w 9p d - sub m ale rs 485 2w 9p d - sub male 1 rx - 6 data - d - 2 rx+ 9 d ata+ d+ 5 gnd 5 gnd gnd mt6050i/mt8050i com1 rs485 2 w 9p d - sub fem ale com 3 rs485 2 w 9p d - sub fem ale rs 485 2w 9p d - sub male 1 rx - 7 data - d - 2 rx+ 8 data+ d+ 5 gnd 5 gnd gnd www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 682 direct connect (crossover cable): hmi rj45 m ale wire color plc rj45 m ale 1 tx+ white/orange 3 rx+ 2 tx - orange 6 rx - 3 rx+ white/green 1 tx+ 4 bd4+ blue 4 bd4+ 5 bd4 - white/blue 5 bd4 - 6 rx - green 2 tx - 7 bd3+ white/brown 7 bd3+ 8 bd3 - brown 8 bd3 - through a hub: hmi rj45 m ale wire color plc rj45 m ale 1 tx+ white/orange 1 tx+ 2 tx - orange 2 tx - 3 rx+ white/green 3 rx+ 4 bd4+ blue 4 bd4+ 5 bd4 - white/blue 5 bd4 - 6 rx - green 6 rx - 7 bd3+ white/brown 7 bd3+ 8 bd3 - brown 8 bd3 - driver version : version date description v1 .00 may/27 /2011 driver released . www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 683 trio modbus rtu, tcp/ip (mode 7) website : http://www.triomotion.com hmi setting: parameters recommend ed option s notes plc type trio modbus rtu, tcp/ip (mode 7) plc i/f rs 485 rs 232/rs 485 /ethernet baud rate 9600 9600 ~ 115200 data b its 8 7, 8 parity even even, odd, none stop b its 1 1 , 2 p ort n o. 502 plc s t a . n o. 1 0 - 255 online s imulator yes broadcast command yes extend address mode yes plc setting: communication mode modbus rtu protocol plc ?? 7 ( ieee floating point ) device a ddress: bit/word device t ype format range memo b vr_bit dddddd 0 ~ 102331 b table_bit ddddddd 0 ~ 3199931 w vr dddd 0 ~ 1023 w table ddddd 0 ~ 31999 www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 684 wiring d iagram: the following represents the view of hmi & plc. 3 trio : rs232 e mt 3 000 series com1 rs232 9p d - sub fem ale com 3 rs232 9p d - sub fem ale rs232 9p d - sub male 2 rx 8 rx t x d 3 tx 7 tx r x d 5 gnd 5 gnd gnd rts circuit cts mt6000 /8000 series except mt6050i/mt8050i com1 rs232 9p d - sub fem ale com2 rs232 9p d - sub fem ale com3 rs232 9p d - sub m ale rs232 9p d - sub male 2 rx 6 rx 8 rx t x d 3 tx 4 tx 7 tx r x d 5 gnd 5 gnd 5 gnd gnd rts circuit cts mt6050i/mt8050i com1 rs232 9p d - sub fem ale rs232 9p d - sub male 9 rx t x d 6 tx r x d 5 gnd gnd rts circuit cts www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 685 the following represents the view of hmi & plc. trio : rs485 4w e mt 3 000 series com1 rs485 4 w 9p d - sub m ale rs 485 4w 9p d - sub male 1 rx - tx - 2 r x + tx+ 3 tx - rx - 4 tx+ rx+ 5 gnd gnd mt6000 /8000 series except mt6050i/mt8050i com1 rs485 4 w 9p d - sub m ale rs 485 4w 9p d - sub male 1 rx - tx - 2 r x + tx+ 3 tx - rx - 4 tx+ rx+ 5 gnd gnd mt6050i/mt8050i com1 rs485 4 w 9p d - sub fem ale rs 485 4w 9p d - s ub male 1 rx - tx - 2 r x + tx+ 3 tx - rx - 4 tx+ rx+ 5 gnd gnd www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 686 the following represents the view of hmi & plc. trio : rs485 2w e mt 3 000 series com1 rs485 2 w 9p d - sub m ale com 3 rs485 2 w 9p d - sub m ale rs 485 2w 9p d - sub male 1 rx - 6 data - d - 2 rx+ 9 data+ d+ 5 gnd 5 gnd gnd mt6000 /8000 series except mt6050i/mt8050i com1 rs485 2 w 9p d - sub m ale com 3 rs485 2 w 9p d - sub m ale rs 485 2w 9p d - sub male 1 rx - 6 data - d - 2 rx+ 9 data+ d+ 5 gnd 5 gnd gnd mt6050i/mt80 50i com1 rs485 2 w 9p d - sub fem ale com 3 rs485 2 w 9p d - sub fem ale rs 485 2w 9p d - sub male 1 rx - 7 data - d - 2 rx+ 8 data+ d+ 5 gnd 5 gnd gnd www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 687 direct connect (crossover cable): hmi rj45 m ale wire color plc rj45 m ale 1 tx+ white/orange 3 rx+ 2 tx - orange 6 rx - 3 rx+ white/green 1 tx+ 4 bd4+ blue 4 bd4+ 5 bd4 - white/blue 5 bd4 - 6 rx - green 2 tx - 7 bd3+ white/brown 7 bd3+ 8 bd3 - brown 8 bd3 - through a hub: hmi rj45 m ale wire color plc rj45 m ale 1 tx+ white/orange 1 tx+ 2 tx - orang e 2 tx - 3 rx+ white/green 3 rx+ 4 bd4+ blue 4 bd4+ 5 bd4 - white/blue 5 bd4 - 6 rx - green 6 rx - 7 bd3+ white/brown 7 bd3+ 8 bd3 - brown 8 bd3 - driver version : version date description v1 .00 apr/20/2012 driver released . www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 688 vigor supported s eries : vigor m series and vb series . website: http://www.vigorplc.com.tw/ hmi setting: parameters recommend ed option s notes plc type vigor plc i/f rs232 rs232, rs485 4 w baud rate 19200 data b its 7 parity even stop b its 1 plc s t a . n o. 1 device a ddress: bit/word device t ype format range memo b x ooo 0 ~ 377 b y ooo 0 ~ 377 b m dddd 0 ~ 7999 b t ddd 0 ~ 255 b c ddd 0 ~ 255 b s m dddd 900 0 ~ 9255 w tv ddd 0 ~ 255 w cv ddd 0 ~ 199 w d dddd 0 ~ 9255 w cv2 ddd 20 0 ~ 255 w sd dddd 9000 ~ 9255 www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 689 wiring d iagram: the following represents the view of hmi & plc. vigor m series : rs485 4w terminal e mt 3 000 series com1 rs485 4 w 9p d - sub m ale vigor m series rs485 4w 6p terminal 1 rx - tx - 2 r x + tx+ 3 tx - rx - 4 tx+ rx+ 5 gnd s g mt6000 /8000 series except mt6050i/mt8050i com1 rs485 4 w 9p d - sub m ale vigor m series rs485 4w 6p terminal 1 rx - tx - 2 r x + tx+ 3 tx - rx - 4 tx+ rx+ 5 gnd s g www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 690 mt6050i/mt805 0i com1 rs485 4 w 9p d - sub fem ale vigor m series rs485 4w 6p terminal 1 rx - tx - 2 r x + tx+ 3 tx - rx - 4 tx+ rx+ 5 gnd s g the following represents the view of hmi & plc. vigor m series : rs 232 e mt 3 000 series com1 rs232 9p d - sub fem ale com 3 rs232 9p d - sub fem ale vigor m series rs 232 9 p d - sub male 2 rx 8 rx 3 t x d 3 tx 7 tx 2 r x d 5 gnd 5 gnd 5 gnd mt6000 /8000 series except mt6050i/mt8050i com1 rs232 9p d - sub fem ale com2 rs232 9p d - sub fem ale com3 rs232 9p d - sub m ale vigor m series rs 232 9 p d - sub male 2 rx 6 rx 8 rx 3 t x d 3 tx 4 tx 7 tx 2 r x d 5 gnd 5 gnd 5 gnd 5 gnd www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 691 mt6050i/mt8050i com1 rs232 9p d - sub fem ale vigor m series rs 232 9 p d - sub male 9 rx 3 t x d 6 tx 2 r x d 5 gnd 5 gnd driver version : version date description v1. 1 0 dec/30/2008 www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 692 vipa 200 hmi setting: parameters recommend ed option s notes plc type vipa 200 plc i/f rs 485 2w rs485 2w baud rate 9600 9600, 19200 , 187.5k the hmi which has a st icker mpi187.5 on the rear cover suppo rt s 187.5 k data b its 8 7, 8 parity even even, odd, none stop b its 1 1 , 2 plc s t a . n o. 2 1 ~ 126 turn around delay (ms) 5 reserved 1 30 ack delay time online s imulator yes extend address mode no broadcast command no plc setting: communica tion mode set station number to 2 device a ddress: bit/word device t ype format range memo b i ddddo 0 ~ 40957 input (i) b q ddddo 0 ~ 40957 output (o) b m ddddo 0 ~ 40957 bit memory b vw _ b it dddddo 0 ~ 102397 v memory b it a ddress byte vb ddddd 0 ~ 10 239 w vw ddddd 0 ~ 10239 v m emory w vw _odd ddddd 0 ~ 10239 v m emory dw vd ddddd 0 ~ 10239 v m emory d ouble w ord dw vd_odd ddddd 0 ~ 10239 v m emory d ouble w ord www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 693 bit/word device t ype format range memo w vw_string ddddd 0 ~ 10239 string w vw_string_odd ddddd 0 ~ 10239 string d w vd_string ddd dd 0 ~ 10239 string d w vd_string_odd ddddd 0 ~ 10239 string byte mb ddddd 0 ~ 10239 b yte m emory w mw ddddd 0 ~ 10239 word m emory dw md ddddd 0 ~ 10239 word m emory w mw_odd ddddd 0 ~ 10239 word m emory w t ddd 0 ~ 127 timer w c ddd 0 ~ 127 counter ? do uble word and f loating point value must use vd device type. wiring d iagram: the following represents the view of hmi & plc. e mt 3 000 series com1 rs485 2 w 9p d - sub m ale com 3 rs485 2 w 9p d - sub m ale rs 485 2w 9p d - sub male 1 rx - 6 data - 8 d - 2 rx+ 9 data+ 3 d+ 5 gnd 5 gnd 5 gnd mt6000 /8000 series except mt6050i/mt8050i com1 rs485 2 w 9p d - sub m ale com 3 rs485 2 w 9p d - sub m ale rs 485 2w 9p d - sub male 1 rx - 6 data - 8 d - 2 rx+ 9 data+ 3 d+ 5 gnd 5 gnd 5 gnd www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 694 mt6050i/mt8050i com1 rs485 2 w 9p d - sub fem ale com 3 rs485 2 w 9p d - sub fem ale rs 485 2w 9p d - sub male 1 rx - 7 data - 8 d - 2 rx+ 8 data+ 3 d+ 5 gnd 5 gnd 5 gnd driver version : version date description v2.30 aug/17/2009 v2.40 nov/1/2011 add device type : md www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 695 vipa 2 00 (vd any address) hmi setting: parameters recommend ed option s notes plc type vipa 200 (vd any address) plc i/f rs 485 2w rs485 2w baud rate 9600 9600, 19200 , 187.5k the hmi which has a st icker mpi187.5 on the rear cover support s 187.5 k data b its 8 7, 8 parity even even, odd, none stop b its 1 1 , 2 plc s t a . n o. 2 1 ~ 126 turn around delay 5 reserved 1 30 ack delay time online s imulator yes extend address mode no broadcast command no plc setting: communication mode set station numb er to 2 device a ddress: bit/word device t ype format range memo b i ddddo 0 ~ 40957 input (i) b q ddddo 0 ~ 40957 output (o) b m ddddo 0 ~ 40957 bit memory b vw _ b it dddddo 0 ~ 102397 v memory b it a ddress w vw ddddd 0 ~ 10239 v m emory dw vd ddddd 0 ~ 10239 v m emory d ouble w ord w vw_string ddddd 0 ~ 10239 string d w vd_string ddddd 0 ~ 10239 string www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 696 bit/word device t ype format range memo w mw ddddd 0 ~ 10239 word m emory w t ddd 0 ~ 127 timer w c ddd 0 ~ 127 counter dw md ddddd 0 ~ 10239 word m emory ? double word and f loating point value must use vd device type. ? vd register can set to any value, not necessarily a multiple of 4. wiring d iagram: the following represents the view of hmi & plc. e mt 3 000 series com1 rs485 2 w 9p d - sub m ale com 3 rs485 2 w 9p d - sub m ale rs 485 2w 9p d - sub male 1 r x - 6 data - 8 d - 2 rx+ 9 data+ 3 d+ 5 gnd 5 gnd 5 gnd mt6000 /8000 series except mt6050i/mt8050i com1 rs485 2 w 9p d - sub m ale com 3 rs485 2 w 9p d - sub m ale rs 485 2w 9p d - sub male 1 rx - 6 data - 8 d - 2 rx+ 9 data+ 3 d+ 5 gnd 5 gnd 5 gnd mt6050i/mt8050i com1 rs485 2 w 9p d - sub fem ale com 3 rs485 2 w 9p d - sub fem ale rs 485 2w 9p d - sub male 1 rx - 7 data - 8 d - 2 rx+ 8 data+ 3 d+ 5 gnd 5 gnd 5 gnd www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 697 driver version : version date description v1.20 nov/16/2011 add device type : md www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 698 vipa 200, for ex. 214 - 2bt10 (ethernet) hmi setting: parameters recommend ed option s notes plc type vipa 200, for ex. 214 - 2bt10 (ethernet) plc i/f ethernet port n o. 102 plc s t a . n o. 1 0 - 31 device a ddress: bit/word device t ype format range memo b i ddddo 0 ~ 40957 input (i) b q ddddo 0 ~ 40957 output (o) b m ddddo 0 ~ 40957 bit memory b vw _ b it dddd d o 0 ~ 102397 v memory b it a ddress w vw ddddd 0 ~ 1023 9 v m emory dw vd ddddd 0 ~ 1023 9 v m emory d ouble w ord w vw _string ddddd 0 ~ 1023 9 string dw vd_string ddddd 0 ~ 1023 9 string dw md ddddd 0 ~ 10239 word m emory ? double word and f loating point value must use vd device type. www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 699 wiring d iagram: direct connect (crossover cable): hmi rj45 m ale wire color plc rj45 m ale 1 tx+ white/orange 3 rx+ 2 t x - orange 6 rx - 3 rx+ white/green 1 tx+ 4 bd4+ blue 4 bd4+ 5 bd4 - white/blue 5 bd4 - 6 rx - green 2 tx - 7 bd3+ white/brown 7 bd3+ 8 bd3 - brown 8 bd3 - through a hub: hmi rj45 m ale wire color plc rj45 m ale 1 tx+ white/orange 1 tx+ 2 tx - orange 2 tx - 3 rx+ white/green 3 rx+ 4 bd4+ blue 4 bd4+ 5 bd4 - white/blue 5 bd4 - 6 rx - green 6 rx - 7 bd3+ white/brown 7 bd3+ 8 bd3 - brown 8 bd3 - driver version : version date description v1.20 dec/30/2008 v1.40 nov/15/2011 add device type : md www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 700 vi pa 300 hmi setting: parameters recommend ed option s notes plc type vipa 300 plc i/f rs 232 baud rate 19200 , 38400 , 187.5k 9600 ~187.5k must be same as the plc setting . the hmi which has a st icker mpi187.5 on the rear cover support s 187.5 k. data b its 8 parity odd stop b its 1 plc s t a . n o. 2 must be same as the plc setting . device a ddress: bit/word device t ype format range memo b i ddddo 0 ~ 40957 input (i) b q ddddo 0 ~ 40957 output (o) b m ddddo 0 ~ 40957 bit memory b d b n bit ffffddddo 0 ~ 409681927 data r egister b it b db0bit ~ db99bit ddddo 0 ~ 81927 w iw dddd 0 ~ 4095 input (i) w qw dddd 0 ~ 4095 output (o) w mw dddd 0 ~ 4095 bit memory d w md dddd 0 ~ 4094 byte mb dddd 0 ~ 4095 bit memory byte byte dbbn ffffdddd 0 ~ 40968192 da ta r egister byte w dbn ffffdddd 0 ~ 4096 8192 data r egister (must be even) d w d b dn ffffdddd 0 ~ 4096 8192 data r egister d ouble w ord (must be multiple of 4) w dbn_string ffffdddd 0 ~ 4096 8192 data r egister d ouble w ord (must be multiple of 4) www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 701 bit/word device t ype format range memo dw dbdn_str ing ffffdddd 0 ~ 4096 8192 data r egister d ouble w ord (must be multiple of 4) w db0 - db99 dddd 0 ~ 8192 data r egister (must be even) * double word and f loating point value must use dbdn device type. how to import tag : siemens step 7 program allows building files of user - defined tag ( *.dif file and *.awl file), and import these files in easybuilder8000/easybuilderpro - > system parameter settings. the following describes how to build and import these two types of files. 1. building * .dif file a in symbols create user - defined tag. www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 702 b click export to export the edited file and click save . 2. building *.awf file a in blocks create items as shown below: b open lad/stl , fbd C programming s7 b lock s , click file - > generate source . www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 703 c select sources as storage path, s pecify the file name then click ok . d select the objects to be exported then click ok . www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 704 e u nder sources there will be names of the saved files, select export s ource to build *.awl file. t he generated *. dif and *. awl files can be imported in easybuil der8000/easybuilderpro system parameter settings , by clicking import tag . tag information successfully imported. www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 705 wiring d iagram: the following represents the view of hmi & plc. siemens s7 - 300 pc adapter : 9p d - sub to 9p d - sub: e mt 3 000 series com1 rs 232 9p d - sub fem ale com 3 rs232 9p d - sub fem ale rs232 9 p d - sub male 2 rx 8 rx 3 t x d 3 tx 7 tx 2 r x d 5 gnd 5 gnd 5 gnd 7 rts circuit 8 cts mt6000 /8000 series except mt6050i/mt8050i com1 rs232 9p d - sub fem ale com2 rs232 9p d - sub fem al e com3 rs232 9p d - sub m ale rs232 9 p d - sub male 2 rx 6 rx 8 rx 3 t x d 3 tx 4 tx 7 tx 2 r x d 5 gnd 5 gnd 5 gnd 5 gnd 7 rts circuit 8 cts mt6050i/mt8050i com1 rs232 9p d - sub fem ale rs232 9 p d - sub male 9 rx 3 t x d 6 tx 2 r x d 5 gnd 5 g nd 7 rts circuit 8 cts www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 706 the following represents the view of hmi & plc. systeme helmholz ssw7 - ts : 9p d - sub to 9p d - sub e mt 3 000 series com1 rs232 9p d - sub fem ale com 3 rs232 9p d - sub fem ale rs232 9 p d - sub male 2 rx 8 rx 3 t x d 3 tx 7 tx 2 r x d 5 gnd 5 gnd 5 gnd 7 rts circuit 8 cts 4 dtr circuit 6 dsr mt6000 /8000 series except mt6050i/mt8050i com1 rs232 9p d - sub fem ale com2 rs232 9p d - sub fem ale com3 rs232 9p d - sub m ale rs232 9 p d - sub male 2 rx 6 rx 8 rx 3 t x d 3 tx 4 tx 7 tx 2 r x d 5 gnd 5 gnd 5 gnd 5 gnd 7 rts circuit 8 cts 4 dtr circuit 6 dsr www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 707 mt6050i/mt8050i com1 rs232 9p d - sub fem ale rs232 9 p d - sub male 9 rx 3 t x d 6 tx 2 r x d 5 gnd 5 gnd 7 rts circuit 8 cts 4 dtr circuit 6 dsr driver version : version date description v 3.10 may/24/2011 a dded registers: mb & dbbn. www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 708 vipa 300 mpi hmi setting: parameters recommend ed option s notes plc type vipa 300 mpi plc i/f rs - 485 2 w baud rate 187.5k only hmi with a sticker mpi 187.5k on the rear cover supports mpi communication . data b its 8 parity even stop b its 1 plc s t a . n o. 2 2 ~ 31 online simulator no extend address mode yes broadcast command no device address: bit/word device t ype format range memo b i ddddo 0 ~ 40957 input (i) b q ddddo 0 ~ 40957 output (o) b m ddddo 0 ~ 40957 bit memory b dbnbit ffffddddo 0 ~ 4096 9999 7 data r egister b it b d b0bit ~ d b 9 9bit dddddo 0 ~ 655327 data r egister b it w iw dddd 0 ~ 4095 input (i) w qw dddd 0 ~ 4095 outpu t (o) w mw dddd 0 ~ 4095 bit memory d w md dddd 0 ~ 4094 byte mb dddd 0 ~ 4095 bit memory byte byte dbbn ffffdddd 0 ~ 40969999 data r egister w dbn ffffdddd 0 ~ 4096 9999 data r egister ( must be even) d w d b dn ffffdddd 0 ~ 4096 9999 data r egister d ouble w ord w dbn_string ffffdddd 0 ~ 4096 9999 d w dbdn_string ffffdddd 0 ~ 4096 9999 w db0 ~ db99 ddddd 0 ~ 65532 data r egister ( must be even) * double w ord and f loating p oint value must use dbdn device type. www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 709 multi - hmis - multi - plcs communication setting: f or siemens s7 - 300 mpi driver in multi - hmis - multi - plcs communication , [max. station no. (mpi network)] parameter must be correctly set. this setting is relevant to the station no. of the devices, as shown, two hmi (station no. 0 , 1 ) and two plc (station no. 2, 3) are in mpi network, max. station no. should be set to 3. www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 710 f o r the effectiveness of communication, users may set plc device in step 7 as shown below. in properties mpi / network settings, set highest mpi address to the number closest to the actua l device station number. note : hmi st a . no. can not be the same as plc st a . no. h i ghly recommended that the device station numbers start from 0 sequentially and correctly set [max. station no. (mpi network)]. available for e asybuilder v4.50 and later. how to import tag : siemens s tep 7 program allows building files of user - defined tag ( *.dif file and *.awl file), and import these files in easybuilder8000/easybuilderpro - > system parameter settings. the following describes how to build and import these two types of files. 1. building * .dif file a in symbols create user - defined tag. www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 711 www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 712 b click export to export the edited file and click save . 2. building *.awf file a in blocks create items as shown below: b open lad/stl , fbd C programming s7 b lock s , click file - > generate source . www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 713 c sele ct sources as storage path, specify the file name then click ok . d select the objects to be exported then click ok . www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 714 e u nder sources there will be names of the saved files, select export s ource to build *.awl file. t he generated *. dif and *. awl file s can be imported in easybuilder8000/easybuilderpro system parameter settings , by clicking import tag . tag information successfully imported. www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 715 wiring diagram: the following represents the view of hmi & plc. s7 - 200 ppi , s7 - 300 mpi :rs485 2w e mt 3 000 s eries com1 rs485 2 w 9p d - sub m ale com 3 rs485 2 w 9p d - sub m ale rs 485 2w 9p d - sub male 1 rx - 6 data - 8 d - 2 rx+ 9 data+ 3 d+ 5 gnd 5 gnd 5 gnd mt6000 /8000 series except mt6050i/mt8050i com1 rs485 2 w 9p d - sub m ale com 3 rs485 2 w 9p d - sub m ale rs 485 2w 9p d - sub male 1 rx - 6 data - 8 d - 2 rx+ 9 data+ 3 d+ 5 gnd 5 gnd 5 gnd mt6050i/mt8050i com1 rs485 2 w 9p d - sub fem ale com 3 rs485 2 w 9p d - sub fem ale rs 485 2w 9p d - sub male 1 rx - 7 data - 8 d - 2 rx+ 8 data+ 3 d+ 5 gnd 5 gnd 5 gnd driver version: version date description v1. 9 0 may/26/2011 added registers: mb & dbbn v2.00 aug/19d/2011 i series hmi support multi hmis - multi plcs communication. www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 716 vipa 300s (ethernet) hmi setting: parameters recommend ed option s notes plc typ e vipa 300s (ethernet) plc i/f ethernet port n o. 102 link t ype pg pc, op rack 0 0 - 7 cpu s lot 3 2 - 31 plc s t a . n o. 0 0 - 31 device a ddress: bit/word device t ype format range memo b i ddddo 0 ~ 40957 input (i) b q ddddo 0 ~ 40957 output (o) b m ddddo 0 ~ 40957 bit memory b dbnbit fff ff fddddo 0 ~ 65535 9999 7 b d b0bit - d b 9 9bit dddddo 0 ~ 655327 data r egister b it w iw dddd 0 ~ 4095 input (i) w qw dddd 0 ~ 4095 output (o) w mw dddd 0 ~ 4095 bit memory d w md dddd 0 ~ 4094 w dbn ff f ffdddd 0 ~ 65535 9999 data r egister (must be even) d w d b dn fff f fdddd 0 ~ 65535 9999 data r egister d ouble w ord (must be multiple of 4) w dbn_string ff f ffdddd 0 ~ 65535 9999 dw dbdn_string ff f ffdddd 0 ~ 65535 9999 w db0 ~ db99 ddddd 0 ~ 65532 data r egister (must be even) byte mb dddd 0 ~ 4095 bit memory byte byte dbbn ff f ffdddd 0 ~ 65535 9999 data r egister byte * double word and f loating point value must use dbdn device type. www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 717 wiring d iagram: direct connect (crossover cable): hmi rj45 m ale wire color plc rj45 m al e 1 tx+ white/orange 3 rx+ 2 tx - orange 6 rx - 3 rx+ white/green 1 tx+ 4 bd4+ blue 4 bd4+ 5 bd4 - white/blue 5 bd4 - 6 rx - green 2 tx - 7 bd3+ white/brown 7 bd3+ 8 bd3 - brown 8 bd3 - through a hub: hmi rj45 m ale wire color plc rj45 m ale 1 tx+ wh ite/orange 1 tx+ 2 tx - orange 2 tx - 3 rx+ white/green 3 rx+ 4 bd4+ blue 4 bd4+ 5 bd4 - white/blue 5 bd4 - 6 rx - green 6 rx - 7 bd3+ white/brown 7 bd3+ 8 bd3 - brown 8 bd3 - www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 718 e asy b uilder device setting steps 1. open e asy b uilder , file / new, select hmi model a nd press [ok ] . 2. s ystem p arameter s ettings window is shown , click [ new ] . 3. select siemens s7 - 400(ethernet) . 4. press [ settings ] . 5. set s7 - 400 ip, port no. , link type, rack and cpu slot. ( must match plc settings ) 1. 2 . www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 719 6. the setting will be finished a s b elow . how to import tag : siemens step 7 program allows building files of user - defined tag ( *.dif file and *.awl file), and import these files in easybuilder8000/easybuilderpro - > system parameter settings. the following describes how to build and import these two types of files. 1. building * .dif file a in symbols create user - defined tag. www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 720 b click export to export the edited file and click save . 2. building *.awf file a in blocks create items as shown below: b open lad/stl , fbd C programming s7 b lock s , click fi le - > generate source . www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 721 c select sources as storage path, specify the file name then click ok . d select the objects to be exported then click ok . www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 722 e u nder sources there will be names of the saved files, select export s ource to build *.awl file. t he generated *. dif and *. awl files can be imported in easybuilder8000/easybuilderpro system parameter settings , by clicking import tag . tag information successfully imported. driver version : version date description v1. 5 0 aug/03/2012 d evice types db n, dbdn is extended to 655359999. www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 723 vipa 300s, for ex. 315 - 4ne12 (ethernet) hmi setting: parameters recommend ed option s notes plc type vipa 300s, for ex. 315 - 4ne12 (ethernet) plc i/f ethernet port n o. 102 plc s t a . n o. 1 0 - 31 device a ddress: bit /word device t ype format range memo b i ddddo 0 ~ 40957 input (i) b q ddddo 0 ~ 40957 output (o) b m ddddo 0 ~ 40957 bit memory b dbnbit ffffddddo 0 ~ 4096 9999 7 b d b0bit - d b 9 9bit dddddo 0 ~ 655327 data r egister b it w iw dddd 0 ~ 4095 input (i) w qw dddd 0 ~ 4095 output (o) w mw dddd 0 ~ 4095 bit memory d w md dddd 0 ~ 4094 bit memory double word w dbn ffffdddd 0 ~ 4096 9999 data r egister (must be even) d w d b dn ffffdddd 0 ~ 4096 9999 data r egister d ouble w ord (must be multiple of 4) w dbn_string ff ffdddd 0 ~ 4096 9999 dw dbdn_string ffffdddd 0 ~ 4096 9999 w db0 ~ db99 ddddd 0 ~ 65532 data r egister (must be even) byte mb dddd 0 ~ 4095 bit memory byte byte dbbn ffffdddd 0 ~ 40969999 data r egister byte ? double word and f loating point value must use dbdn device type. www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 724 how to import tag : siemens step 7 program allows building files of user - defined tag ( *.dif file and *.awl file), and import these files in easybuilder8000/easybuilderpro - > system parameter settings. the following describes how to buil d and import these two types of files. 1. building * .dif file a in symbols create user - defined tag. www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 725 b click export to export the edited file and click save . 2. building *.awf file a in blocks create items as shown below: b open lad/stl , fbd C programming s7 b lock s , click file - > generate source . www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 726 c select sources as storage path, specify the file name then click ok . d select the objects to be exported then click ok . www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 727 e u nder sources there will be names of the saved files, select export s ource to build *.awl file. t he generated *. dif and *. awl files can be imported in easybuilder8000/easybuilderpro system parameter settings , by clicking import tag . tag information successfully imported. www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 728 wiring d iagram: direct connect (crossover cable): hmi rj 45 m ale wire color plc rj45 m ale 1 tx+ white/orange 3 rx+ 2 tx - orange 6 rx - 3 rx+ white/green 1 tx+ 4 bd4+ blue 4 bd4+ 5 bd4 - white/blue 5 bd4 - 6 rx - green 2 tx - 7 bd3+ white/brown 7 bd3+ 8 bd3 - brown 8 bd3 - through a hub: hmi rj45 m ale wir e color plc rj45 m ale 1 tx+ white/orange 1 tx+ 2 tx - orange 2 tx - 3 rx+ white/green 3 rx+ 4 bd4+ blue 4 bd4+ 5 bd4 - white/blue 5 bd4 - 6 rx - green 6 rx - 7 bd3+ white/brown 7 bd3+ 8 bd3 - brown 8 bd3 - driver version : version date description v 2.10 may/21/2011 added registers: mb & dbbn. www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 729 xinje xc series s upported series: xinje xc s eries w ebsite: http://www.xinje.com/0/index.html hmi setting: parameters recommend ed option s notes plc type xi nje xc series plc i/f rs232 rs232 baud rate 19200 data b its 8 parity even stop b its 1 plc s t a. n o. 1 0 - 2 55 device a ddress: bit/word device t ype format range memo b m dddd 0 ~ 8511 b x oooo 0 ~ 1037 b y oooo 0 ~ 1037 b s dddd 0 ~ 1 023 b t ddd 0 ~ 618 b c ddd 0 ~ 634 w d dddd 0 ~ 8511 w td ddd 0 ~ 618 w cd ddd 0 ~ 634 w fd_1 dddd 0 ~ 5000 w fd_2 dddd 8000 ~ 8511 www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 730 wiring d iagram: the following represents the view of hmi & plc. driver version: e mt 3 000 series com1 rs23 2 9p d - sub fem ale com 3 rs232 9p d - sub fem ale rs232 8p mini - din male 2 rx 8 rx 5 t x 3 tx 7 tx 4 r x 5 gnd 5 gnd 8 gnd mt6000 /8000 series except mt6050i/mt8050i com1 rs232 9p d - sub fem ale com2 rs232 9p d - sub fem ale com3 rs232 9p d - sub m ale rs2 32 8p mini - din male 2 rx 6 rx 8 rx 5 t x 3 tx 4 tx 7 tx 4 r x 5 gnd 5 gnd 5 gnd 8 gnd mt6050i/mt8050i com1 rs232 9p d - sub fem ale rs232 8p mini - din male 9 rx 5 t x 6 tx 4 r x 5 gnd 8 gnd version date description v1.00 jul/02/20 09 driver released . www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 731 yamaha ercd hmi setting: device a ddress : bit/word device type format range memo word p ddd 0 ~ 999 read/write, pnt point data word swi d 0 write only rw0=program number switches program number to run word org d 0 write only r eturns to origin word r eset d 0 write only r eset program word run d 0 write only s tarts automatic operation word x_add d 0 write only x command word x_sub d 0 write only x command word movd d 0 write only d irectly moves to specified position rw1=x - axis position(mm), rw2=speed parameters recommend ed option s notes plc type yamaha ercd plc i/f rs232 baud rate 9600 1200 - 19200 data bits 8 7 or 8 parity odd none/even/odd stop bits 1 1 or 2 plc s t a . n o. 0 needn t to set the station no. www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 732 wiring d iagram : the following represents the view of hmi & plc. e mt 3 000 series com1 rs232 9p d - sub fem ale com 3 rs232 9p d - sub fem ale rs232 9p d - sub male 2 rx 8 rx 3 t x 3 tx 7 tx 2 r x 5 gnd 5 gnd 5 gnd 7 rts circuit 8 cts mt6000 /8 000 series except mt6050i/mt8050i com1 rs232 9p d - sub fem ale com2 rs232 9p d - sub fem ale com3 rs232 9p d - sub m ale rs232 9p d - sub male 2 rx 6 rx 8 rx 3 t x 3 tx 4 tx 7 tx 2 r x 5 gnd 5 gnd 5 gnd 5 gnd 7 rts circuit 8 cts mt6050i/mt8050i com1 rs232 9p d - sub fem ale rs232 9p d - sub male 9 rx 3 t x 6 tx 2 r x 5 gnd 5 gnd 7 rts circuit 8 cts www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 733 driver version : version date description v1. 3 0 jan/04/2010 www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 734 yaskawa ccmep supported series: yaskawa ccmep - 100/ ccmep - 200 website : http://www.yaskawa - control.co.jp/english/jigyo/mechotronics.html hmi setting: parameters recommend ed option s notes plc type yaskawa ccmep plc i/f rs485 4w baud rate 384 00 data b its 8 parity even stop b its 1 plc s t a . n o. 1 device a ddress: bit/word device t ype format range memo b 4_bit ddddddd 100 ~ 6553515 w 4 ddddd 1 ~ 65535 wiring d iagram: the following represents the view of hmi & plc. e mt 3 000 ser ies com1 rs485 4 w 9p d - sub m ale rs485 4w 8p rj45 male 1 rx - 4 tx - 2 r x + 3 tx+ 3 tx - 2 rx - 4 tx+ 1 rx+ 5 gnd 8 gnd www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 735 mt6000 /8000 series except mt6050i/mt8050i com1 rs485 4 w 9p d - sub m ale rs485 4w 8p rj45 male 1 rx - 4 tx - 2 r x + 3 tx+ 3 tx - 2 rx - 4 tx+ 1 rx+ 5 gnd 8 gnd mt6050i/mt8050i com1 rs485 4 w 9p d - sub fem ale rs485 4w 8p rj45 male 1 rx - 4 tx - 2 r x + 3 tx+ 3 tx - 2 rx - 4 tx+ 1 rx+ 5 gnd 8 gnd driver version : version date description v1. 0 0 jun/14/2012 driver released . www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 736 yaskawa memobus (mp series controllers) supported s eries: yaskawa mp2200, mp2300, mp2300s, mp9xx communication module . website: http://www.yaskawa.com/ hmi setting: parameter s recommend ed option s notes plc type yaskawa memobus (mp series controllers) plc i/f rs485 /ethernet rs232/ rs485 2w/ 4 w, ethernet baud rate 19200 9600 ~57600 data b its 8 parity even stop b its 1 port n o. 502 default ethernet module o nly plc s t a . n o. 1 1 - 31 plc setting: communication mode memobus, slave, rtu plc ethernet setting: 1. use mpe720 program s oftware, o pen module configuration , d ouble click 218ifa. www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 737 2. in transmision parame ters input mp2300s ip address, s ubnet mask, gateway ip. in co nnection parameter, cno - 1 input: local port=502, node ip address=000.000.000.000, node port=00000, connect type=tcp, protocol type=memobus, code=rtu. 3. click mechatrolink t o set up mp2300s plc as master. 4. close all dialogs and save to mp2300s. www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 738 note: 1. only cno 01 can auto communicat e with one hmi. o ther cno need a ladder program created for communication. 2. dip sw2 - 2 of mp2300s must be set to off position during normal com munication, otherwise , ip address will be eras ed after reset power, and it will be unable to commu nicate with hmi when set to o n position . device address: bit/word device t ype format range memo b mb_1 ddddh 0 ~ 9999f mb 0 ~ 9999 b mb_2 dddddh 100000 ~ 65534f mb 10000 ~ 65535 b ib hhhhh 0 ~ a7ff0 read only b iw_bit hhhhdd 0~ a7ff1 5 w iw hhhh 0 ~ a7ff read only dw il hhhh 0 ~ a7ff read only dw (f) if hhhh 0 ~ a7ff read only w mw ddddd 0 ~ 65534 holdin g r egister dw ml ddddd 0 ~ 65533 double word dw (f) mf ddddd 0 ~ 65533 floating point *: when connect via ethernet interface t he max range of iw, il and if would be restricted . wiring d iagram: the following represents the view of hmi & plc. 9p d - sub to 9p d - sub: 217if - 01, 218if - 01 e mt 3 000 series com1 rs232 9p d - sub fem ale com 3 rs232 9p d - sub fem ale rs232 9p d - sub male 2 rx 8 r x 2 t x 3 tx 7 tx 3 r x 5 gnd 5 gnd 7 gnd www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 739 mt6000 /8000 series except mt6050i/mt8050i com1 rs232 9p d - sub fem ale com2 rs232 9p d - sub fem ale com3 rs232 9p d - sub m ale rs232 9p d - sub male 2 rx 6 rx 8 rx 2 t x 3 tx 4 tx 7 tx 3 r x 5 gnd 5 gnd 5 gn d 7 gnd mt6050i/mt8050i com1 rs232 9p d - sub fem ale rs232 9p d - sub male 9 rx 2 t x 6 tx 3 r x 5 gnd 7 gnd the following represents the view of hmi & plc. 217if - 01 rs485 2w: e mt 3 000 series com1 rs485 2 w 9p d - sub m ale com 3 rs485 2 w 9p d - sub m ale 217if - 01 rs 485 14 p connector 1 rx - 6 data - 2, 4 d - 2 rx+ 9 data+ 1, 3 d + 5 gnd 5 gnd 14 gnd www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 740 mt6000 /8000 series except mt6050i/mt8050i com1 rs485 2 w 9p d - sub m ale com 3 rs485 2 w 9p d - sub m ale 217if - 01 rs 485 14 p connector 1 rx - 6 data - 2, 4 d - 2 rx+ 9 data+ 1, 3 d + 5 gnd 5 gnd 14 gnd mt6050i/mt8050i com1 rs485 2 w 9p d - sub fem ale com 3 rs485 2 w 9p d - sub fem ale 217if - 01 rs 485 14 p connector 1 rx - 7 data - 2, 4 d - 2 rx+ 8 data+ 1, 3 d + 5 gnd 5 gnd 14 gnd the following represents the view of hmi & plc. 217if - 01 rs4854w : e mt 3 000 series com1 rs485 4 w 9p d - sub m ale 217if - 01 rs 422 14 p connector 1 rx - 2 tx - 2 r x + 1 tx+ 3 tx - 4 rx - 4 tx+ 3 rx+ 5 gnd 14 gnd www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 741 mt6000 /8000 series exc ept mt6050i/mt8050i com1 rs485 4 w 9p d - sub m ale 217if - 01 rs 422 14 p connector 1 rx - 2 tx - 2 r x + 1 tx+ 3 tx - 4 rx - 4 tx+ 3 rx+ 5 gnd 14 gnd mt6050i/mt8050i com1 rs485 4 w 9p d - sub fem ale 217if - 01 rs 422 14 p connector 1 rx - 2 tx - 2 r x + 1 tx+ 3 tx - 4 rx - 4 tx+ 3 rx+ 5 gnd 14 gnd direct connect (crossover cable): hmi rj45 m ale wire color plc rj45 m ale 1 tx+ white/orange 3 rx+ 2 tx - orange 6 rx - 3 rx+ white/green 1 tx+ 4 bd4+ blue 4 bd4+ 5 bd4 - white/b lue 5 bd4 - 6 rx - green 2 tx - 7 bd3+ white/brown 7 bd3+ 8 bd3 - brown 8 bd3 - www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 742 through a hub: hmi rj45 m ale wire color plc rj45 m ale 1 tx+ white/orange 1 tx+ 2 tx - orange 2 tx - 3 rx+ white/green 3 rx+ 4 bd4+ blue 4 bd4+ 5 bd4 - white/blue 5 bd4 - 6 rx - green 6 rx - 7 bd3+ white/brown 7 bd3+ 8 bd3 - brown 8 bd3 - driver version : version date description v1.70 dec/20/2010 www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 743 yaskawa mp series ethernet (extension) hmi setting: parameters recommend ed option s notes plc type yaskawa mp series ethernet (extension) plc i/f ethernet (udp) port n o. 10000 plc s t a . n o. 1 plc setting: yaskawa plc communication parameter settings (1) plc factory communication parameter settings: item set ip address 192.168.1.1 subnet mask 255.255.255.0 gat eway ip address 0.0.0.0 system port no. 10000 (udp) tcp zero window timer value 3 (s) tcp retry time 500 (ms) tcp close time 60 (s) ip assemble time 30 (s) max. packet length 1500 (bytes) (2) setting steps: 1. set ip for plc. www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 744 2. communication parameter setting. 3. go to module details and select [ 218ifa ] for setting relevant parameters for ethernet transmission. 4. the settings are shown below, plc ip cant be repeated. www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 745 5. download plc communication parameters to plc, and restart the controller. (3) hmi settings: 1. select ethernet for plc i/f. 2. tick [ udp ] . 3. set plc ip and p ort, the default port is 10000. www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 746 device a ddress : bit/word device type format range memo b sb ddddh 0 ~ 8191 f b ib hhhhh 0 ~ fffff b ob hhhhh 0 ~ fffff b mb dddddh 0 ~ 65534 f w sw dddd 0 ~ 8191 w iw hhhh 0 ~ ffff w ow hhhh 0 ~ ffff w mw ddddd 0 ~ 65534 wiring d iagram: direct connect (crossover cable): hmi rj45 m ale wire color plc rj45 m ale 1 tx+ white/orange 3 rx+ 2 tx - orange 6 rx - 3 rx+ white/green 1 tx+ 4 bd 4+ blue 4 bd4+ 5 bd4 - white/blue 5 bd4 - 6 rx - green 2 tx - 7 bd3+ white/brown 7 bd3+ 8 bd3 - brown 8 bd3 - www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 747 through a hub: hmi rj45 m ale wire color plc rj45 m ale 1 tx+ white/orange 1 tx+ 2 tx - orange 2 tx - 3 rx+ white/green 3 rx+ 4 bd4+ blue 4 bd4+ 5 bd4 - white/blue 5 bd4 - 6 rx - green 6 rx - 7 bd3+ white/brown 7 bd3+ 8 bd3 - brown 8 bd3 - driver version : version date description v1. 1 0 jul/21 /201 1 driver released . www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 748 yaskawa mp 2300siec website: http://www.yaskawa.com/site/home.nsf/home/home.html hmi setting: parameters recommend ed option s notes plc type yaskawa mp2300siec plc i/f ethernet port n o. 44818 assembly instance i nput::101 output:111 input::101~106 o utput:111~116 plc s t a . n o. 1 plc setting: mp2300siec - motion works iec express (yaskawa) settings: step 1 . before hmi communicates with mp2300siec using ethernet/ip, the instance input and instance output of mp2300siec device must be set correctly. mu ltiple instances are allowed to be built at one time, please click [save ] after setting. fig. 1 assembly instances www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 749 step 2 . global variables will automatically add in e/ip input and output data, input and output data name and address type can be user - def ined. fig. 2 global variables step 3 . when download project to device (mp2300siec) , please go to (fig. 3) r esource - >settings to access setting dialog (fig. 4) for setting mp2300siec ip address . fig. 3 motion works iec express C settings www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 750 fig. 4 res ource settings step 4 . start compilation. fig. 5 editing screen www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 751 step 5 . download p roject to device - mp2300siec , and execute cold . fig. 6 project downloading e asybuilder8000/ e asybuilder pro settings: step 1. system parameter settings open e asybui lder8000/ e asybuilder pro project, as shown in fig. 7, assembly instance and size must match the software default factory settings, and please don t select udp . fig.8 below shows how hmi input / output address is mapped to mp2300siec device. fig. 7 insta nce setting www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 752 fig.8 hmi and mp2300siec i/o mapping step 2. address setting: instance 101 and instance 1 11 are defined as 128bytes , on the project window , word objects can be used, with data typed defined as 32 - bit unsigned , input addresses set to 0 2 4 6 ..62 for reading instance 101 data. fig. 9 address setting e asybuilder8000/ e asybuilder pro - a llen b radley compactlogix tag data importing and module defined: step 1 . in e asybuilder8000/ e asybuilder pro project, when using allen bradley eip driver to import csv file (as in fig. 10), please open ab data type editor (fig. 11), and right click on module defined to add new data type. www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 753 f ig. 10 rslogix 5000 (allen bradley software) export free tag csv file fig.11 ab data type editor step 2 . as in fig 12, in ab data type editor add name of the new data type. the name must be set identically to the data type in free tag csv file. as in fig 14, data member name must be set identically to the ab software (as data in fig. 13), then click [save ] (fig. 15). www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 754 fig.12 ab data type editor fig.13 tag information fig.14 add data member - name tag information www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 755 fig. 15 add data member - settings - save step 3 . import csv file, tag information can be viewed from object address. fig . 16 tag information device a ddress : bit/word device type format range memo b input_bit ddd dd dd 0 ~ 6553515 b output_bit ddd dd dd 0 ~ 6553515 dw input ddd dd 0 ~ 65535 dw output ddd dd 0 ~ 65535 www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 756 wiring d iagram: direct connect (crossover cable): hmi rj45 m ale wire color plc r j45 m ale 1 tx+ white/orange 3 rx+ 2 tx - orange 6 rx - 3 rx+ white/green 1 tx+ 4 bd4+ blue 4 bd4+ 5 bd4 - white/blue 5 bd4 - 6 rx - green 2 tx - 7 bd3+ white/brown 7 bd3+ 8 bd3 - brown 8 bd3 - through a hub: hmi rj45 m ale wire color plc rj45 m ale 1 tx+ white/orange 1 tx+ 2 tx - orange 2 tx - 3 rx+ white/green 3 rx+ 4 bd4+ blue 4 bd4+ 5 bd4 - white/blue 5 bd4 - 6 rx - green 6 rx - 7 bd3+ white/brown 7 bd3+ 8 bd3 - brown 8 bd3 - note: the wiring diagrams above are drawn base d on mt8100i structure , the actual placement of pins may vary according to hmi module. driver version : version date description v1.00 aug/24 /2011 driver released . www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 757 yas k awa smc 3010 supported s eries: yaskawa smc series servo motor controller . hmi setting: parameters recomme nd ed option s notes plc type yaskawa smc 3010 plc i/f rs 232 baud rate 19200 9600, 19200 data b its 8 parity no n e stop b its 1 device a ddress: bit/word device t ype format range memo b af d 0 ~ 1 b bn d 0 ~ 1 write only b bp d 0 ~ 1 wri te only b bv d 0 ~ 1 write only b cb dddd 0 ~ 9999 write only b cm d 0 ~ 1 read only b dv d 0 ~ 1 b eb d 0 ~ 1 b oe d 0 ~ 1 b rs d 0 ~ 1 write only b st d 0 ~ 1 write only b tb do 0 ~ 1 7 read only b v_ b it ddddd 0 ~ 99931 *2 b d_arr_bit ddddd 0 ~ 99931 d w ac d 0 ~ 4 dw dc d 0 ~ 4 dw bl d 0 ~ 4 w cd d 0 ~ 2 write only w ce d 0 ~ 2 www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 758 bit/word device t ype format range memo dw de d 0 ~ 4 dw dp d 0 ~ 4 w dt d 0 ~ 2 w ec d 0 ~ 2 dw em d 0 ~ 4 w er d 0 ~ 2 w fa d 0 ~ 2 dw fl d 0 ~ 4 w fv d 0 ~ 2 dw gr d 0 ~ 4 dw jg d 0 ~ 4 dw mm d 0 ~ 4 w mt d 0 ~ 2 w na d 0 ~ 2 w op d 0 ~ 2 dw pa d 0 ~ 4 write only dw pr d 0 ~ 4 dw sp d 0 ~ 4 w tc d 0 ~ 2 read only w tm d 0 ~ 2 w tw d 0 ~ 2 dw va d 0 ~ 4 dw vd d 0 ~ 4 dw vs d 0 ~ 4 dw il d 0 ~ 4 dw it d 0 ~ 4 dw kd d 0 ~ 4 dw ki d 0 ~ 4 dw kp d 0 ~ 4 dw of d 0 ~ 4 dw tl d 0 ~ 4 dw vr d 0 ~ 4 dw vt d 0 ~ 4 dw pf d 0 ~ 4 *1 dw vf d 0 ~ 4 www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 759 bit/word device t ype format range memo dw v ddd 0 ~ 999 *2 f f ddd 0 ~ 999 *2 w d_array ddd 0 ~ 999 w r_array ddd 0 ~ 999 note: *1 pf is the communication parameter of smc_3010, the default is 10.4, if the value is not 10.4, all values will be displayed incorrect ly . *2 user define d integer variable v000~v999, floating point variable f000~f999. wiring d iagram: the following represent s the view of hmi & plc. e mt 3 000 series com1 rs232 9p d - sub fem ale com 3 rs232 9p d - sub fem ale smc3010 cn6 rs232 9p d - sub male 2 rx 8 rx 2 t xd 3 tx 7 tx 3 r xd 5 gnd 5 gnd 5 gnd 7 rts circuit 8 cts mt6000 /8000 series except mt6050i/m t8050i com1 rs232 9p d - sub fem ale com2 rs232 9p d - sub fem ale com3 rs232 9p d - sub m ale smc3010 cn6 rs232 9p d - sub male 2 rx 6 rx 8 rx 2 t xd 3 tx 4 tx 7 tx 3 r xd 5 gnd 5 gnd 5 gnd 5 gnd 7 rts circuit 8 cts www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 760 mt6050i/mt8050i com1 rs232 9p d - sub fem ale smc3010 cn6 rs232 9p d - sub male 9 rx 2 t xd 6 tx 3 r xd 5 gnd 5 gnd 7 rts circuit 8 cts driver version : version date description v1. 30 mar/29/2010 www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 761 yaskawa smc 3010 (e thernet ) supported s eries: yaskawa smc series ser vo motor controller . hmi setting: parameters recommend ed option s notes plc type yaskawa smc 3010 (ethernet) plc i/f ethernet port n o. 23 device a ddress: bit/word device t ype format range memo b af d 0 ~ 1 b bn d 0 ~ 1 write only b bp d 0 ~ 1 write only b bv d 0 ~ 1 write only b cb dddd 0 ~ 9999 write only b cm d 0 ~ 1 read only b dv d 0 ~ 1 b eb d 0 ~ 1 b oe d 0 ~ 1 b rs d 0 ~ 1 write only b st d 0 ~ 1 write only b tb do 0 ~ 17 read only b v_bit ddddd 0 ~ 99931 *2 b d_arr_bit ddddd 0 ~ 99931 d w ac d 0 ~ 4 dw dc d 0 ~ 4 dw bl d 0 ~ 4 w cd d 0 ~ 2 write only w ce d 0 ~ 2 dw de d 0 ~ 4 dw dp d 0 ~ 4 w dt d 0 ~ 2 w ec d 0 ~ 2 www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 762 bit/word device t ype format range memo dw em d 0 ~ 4 w er d 0 ~ 2 w fa d 0 ~ 2 dw fl d 0 ~ 4 w fv d 0 ~ 2 dw gr d 0 ~ 4 dw jg d 0 ~ 4 dw mm d 0 ~ 4 w mt d 0 ~ 2 w na d 0 ~ 2 w op d 0 ~ 2 dw pa d 0 ~ 4 write only dw pr d 0 ~ 4 dw sp d 0 ~ 4 w tc d 0 ~ 2 read only w tm d 0 ~ 2 w tw d 0 ~ 2 dw va d 0 ~ 4 dw vd d 0 ~ 4 dw vs d 0 ~ 4 dw il d 0 ~ 4 dw it d 0 ~ 4 dw kd d 0 ~ 4 dw ki d 0 ~ 4 dw kp d 0 ~ 4 dw of d 0 ~ 4 dw tl d 0 ~ 4 dw vr d 0 ~ 4 dw vt d 0 ~ 4 dw pf d 0 ~ 4 *1 dw vf d 0 ~ 4 dw v ddd 0 ~ 999 *2 w f ddd 0 ~ 999 *2 w d_array ddd 0 ~ 999 w r_array ddd 0 ~ 999 www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 763 note: *1 pf is the communication parameter of smc_3010, the default is 10.4, if the value is not 10.4, all values will be displayed incorrect ly . *2 user define d integer variable v000~v999, floating point variable f000~f999. wiring d iagram: direct connect (crossover cable): hmi rj45 m ale wire color plc rj45 m ale 1 tx+ white/orange 3 rx+ 2 tx - orange 6 rx - 3 rx+ white/green 1 tx+ 4 bd4+ blue 4 bd4+ 5 bd4 - white/blue 5 bd4 - 6 rx - green 2 tx - 7 bd3+ white/brown 7 bd3+ 8 bd3 - brown 8 bd3 - through a hub: hmi rj45 m ale wire color plc rj45 m ale 1 tx+ white/orange 1 tx+ 2 tx - orange 2 tx - 3 rx+ white/green 3 rx+ 4 bd4+ blue 4 bd4+ 5 bd4 - white/blue 5 bd4 - 6 rx - green 6 rx - 7 bd3+ white/brown 7 bd3+ 8 bd3 - brown 8 bd3 - driver version : ver sion date description v1. 10 mar / 2 9 /2010 www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 764 yokogawa fa - m3 supported s eries : fa - m3 cpu sp35 - 5n, sp55 - 5n cpu port, f3lc11 computer link module. website : http://www.yokogawa.com/itc/itc - index - en .htm hmi setting: parameters recommend ed option s notes plc type yokogawa fa - m3 plc i/f rs232 baud rate 19200 9600, 19200 data bits 8 8 parity even even, odd, none stop bits 1 1 plc s t a . n o. 1 1 - 31 plc setting: communication mode use pers onal communication link use checksum use end character widefield communication setting : for widefield commun ication setting, select [tool] / [set environment] , the default is [ automatic ] . using the automatic recognition, wide f ield software will connect th e c urrent plc and get the plc com munication setting. if the plc communication configuration is already known , select the [ fixed ] mode, it will connect with the plc quickly. www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 765 p.s since p ersonal c omputer link is used , when connecting to plc it will delay ab out 20sec for test ing communication. yokogawa plc communcation setting: yokogawa fa - m3 cpu sp55 - 5n (same sp35 - 5n) [file] / [new project] to create a new project . www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 766 c lick [ configuration ] to set up communication. device a ddress: bit/word device t ype form at range memo b x ddddd 0 ~ 71664 b y ddddd 0 ~ 71664 b i ddddd 1 ~ 16384 b m dddd 1 ~ 9984 b l dddd d 0 ~ 7 8192 w d ddddd 1 ~ 16384 w b ddddd 1 ~ 32768 w v ddd 1 ~ 256 w w ddddd 1 ~ 71024 w z dddd 1 ~ 1024 www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 767 wiring d iagram: the follo wing represents the view of hmi & plc. 9p d - sub to 9p d - sub: cable km11 e mt 3 000 series com1 rs232 9p d - sub fem ale com 3 rs232 9p d - sub fem ale rs232 9p d - sub male 2 rx 8 rx 2 t xd 3 tx 7 tx 3 r xd 5 gnd 5 gnd 5 gnd mt6000 /8000 series except mt6 050i/mt8050i com1 rs232 9p d - sub fem ale com2 rs232 9p d - sub fem ale com3 rs232 9p d - sub m ale rs232 9p d - sub male 2 rx 6 rx 8 rx 2 t xd 3 tx 4 tx 7 tx 3 r xd 5 gnd 5 gnd 5 gnd 5 gnd mt6050i/mt8050i com1 rs232 9p d - sub fem ale rs232 9p d - sub male 9 rx 2 t xd 6 tx 3 r xd 5 gnd 5 gnd www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 768 the following represents the view of hmi & plc. 9p d - sub to 9p d - sub: lc11 e mt 3 000 series com1 rs232 9p d - sub fem ale com 3 rs232 9p d - sub fem ale rs232 9p d - sub male 2 rx 8 rx 3 t xd 3 tx 7 tx 2 r xd 5 gnd 5 gnd 5 gnd 7 rts circuit 8 cts mt6000 /8000 series except mt6050i/mt8050i com1 rs232 9p d - sub fem ale com2 rs232 9p d - sub fem ale com3 rs232 9p d - sub m ale rs232 9p d - sub male 2 rx 6 rx 8 rx 3 t xd 3 tx 4 tx 7 tx 2 r xd 5 gnd 5 gnd 5 gnd 5 gnd 7 rts circuit 8 cts mt6050i/mt8050i com1 rs232 9p d - sub fem ale rs232 9p d - sub male 9 rx 3 t xd 6 tx 2 r xd 5 gnd 5 gnd 7 rts circuit 8 cts www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 769 driver version : version date description v1. 2 0 oct/23/2009 v1.30 may/31/2012 extended address l range up to 78192. www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 770 yokogawa fa - m3 (ethernet) supported s eries : fa - m3 cpu sp35 - 5n, sp55 - 5n with f3le01 - 5t/f3le11 - 0t ethernet module. website: http://www.yokogawa .com/itc/itc - index - en.htm hmi setting: parameters recommend ed option s notes plc type yokogawa fa - m3 (ethernet) plc i/f ethernet p ort n o. 1 2289 plc s t a . n o. 1 plc setting: communication mode set ip address , and s et all condition setup switch to off. device address: bit/word device type format range memo b x ddddd 0 ~ 71664 b y ddddd 0 ~ 71664 b i ddddd 1 ~ 16384 b m dddd 1 ~ 9984 b l dddd d 0 ~ 7 8192 w d dddd 1 ~ 8192 w b ddddd 1 ~ 32768 w v dd 1 ~ 64 w w ddddd 1 ~ 71024 w z ddd 1 ~ 512 www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 771 wiring d iagram: direct connect (crossover cable): hmi rj45 m ale wire color plc rj45 m ale 1 tx+ white/orange 3 rx+ 2 tx - orange 6 rx - 3 rx+ white/green 1 tx+ 4 bd4+ blue 4 bd4+ 5 bd4 - white/blue 5 bd4 - 6 rx - green 2 tx - 7 bd3+ white /brown 7 bd3+ 8 bd3 - brown 8 bd3 - through a hub: hmi rj45 m ale wire color plc rj45 m ale 1 tx+ white/orange 1 tx+ 2 tx - orange 2 tx - 3 rx+ white/green 3 rx+ 4 bd4+ blue 4 bd4+ 5 bd4 - white/blue 5 bd4 - 6 rx - green 6 rx - 7 bd3+ white/brown 7 bd 3+ 8 bd3 - brown 8 bd3 - driver version : version date description v1.00 dec/30/2008 driver released . v1.10 may/31/2012 extended address l range up to 78192. www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 7 72 yudian aibus supported s eries: udian automation ai - 501, ai - 518, ai - 519, ai - 701, ai - 702m, ai - 704m, ai - 706m, ai - 719. website: http://www.yudian.us hmi setting: parameters recommend ed option s notes plc type a ibus plc i/f rs 485 2w rs232 baud rate 9600 9600, 19200 data b its 8 parity none stop b its 2 hmi s t a . n o. 0 plc s t a . n o. 1 0 - 100 on - line s imulat ion yes extend address mode no device a ddress: ai - 518 bit/word device t ype format range memo w 0 00h dd sv/step w 1 01h dd - 1999 ~ 9999 hial w 2 02h dd - 1999 ~ 9999 loal w 3 03h dd 0 ~ 9999 dhal w 4 04h dd 0 ~ 9999 dlal w 5 05h dd 0 ~ 2000 df w 6 06h dd 0 ~ 4 ctrl w 7 07h dd 0 ~ 9999 m5 w 8 08h dd 1 ~ 9999 p w 9 09h dd 0 ~ 2000 t www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 773 bit/word device t ype format range memo w 10 0ah dd 0 ~ 125 cti w 11 0bh dd 0 ~ 37 sn (read only) w 12 0ch dd 0 ~ 3 dip (read only) w 13 0 dh dd - 1999 ~ 9999 dil w 14 0eh dd - 1999 ~ 9999 dih w 15 0fh dd 0 ~ 9999 alp w 16 10h dd - 1999 ~ 4000 0.1 sc w 17 11h dd 0 ~ 48 op1 w 18 12h dd - 110 ~ 110% opl w 19 13h dd 0 ~ 110% oph w 20 14h dd 0 ~ 127 cf (read only) w 21 15h dd 0 ~ 19.2k baud rate baud /808p status word: run : 0 suspend : 4 stop : 12 (read only) w 22 16h dd 0 ~ 100 addr w 23 17h dd 0 ~ 20 dl w 24 18h dd 0 ~ 127 run w 25 19h dd 0 ~ 9999 loc ai - 701 bit/word device t ype format range memo w 1 01h dd - 9990 ~ 30000 hial w 2 02h dd - 9990 ~ 30000 loal w 3 03h dd - 9990 ~ 30000 hdal w 4 04h dd - 9990 ~ 30000 ldal w 5 05h dd 0 ~ 2000 ahys w 11 0bh dd 0 ~ 37 inp (read only) w 12 0ch dd 0 ~ 3 dpt w 13 0dh dd - 9999 ~ 30000 scl w 14 0eh dd - 9999 ~ 30000 sch w 15 0fh dd 0 ~ 4444 aop w 16 10h dd - 1999 ~ 4000 0.1 scb www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 774 bit/word device t ype format range memo w 17 11h dd 0 ~ 48 opt w 21 15h dd 0 ~ 19.2k baud rate baud /808p status word run : 0 suspend : 4 stop : 12 (read only) w 22 16h dd 0 ~ 80 addr w 23 17h dd 0 ~ 40 filt w 25 19h dd 0 ~ 255 loc wiring d iagram: the following represents the view of hmi & plc. e mt 3 000 series com1 rs485 2 w 9p d - sub m ale com 3 rs485 2 w 9p d - sub m ale rs 485 2w terminal 1 rx - 6 data - 4 comm a 2 rx+ 9 data+ 3 comm b 5 gnd 5 gnd mt6000 /8000 series except mt6050i/mt8050i com1 rs485 2 w 9p d - sub m ale com 3 rs485 2 w 9p d - sub m ale rs 485 2w terminal 1 rx - 6 data - 4 comm a 2 rx+ 9 data+ 3 comm b 5 gnd 5 gnd www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 775 mt6050i/mt8050i com1 rs485 2 w 9p d - sub fem ale com 3 rs485 2 w 9p d - sub fem ale rs 485 2w terminal 1 rx - 7 data - 4 comm a 2 rx+ 8 data+ 3 comm b 5 gnd 5 gnd driver version : version date description v1.20 dec/30/2008 www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 776 mt6050i /mt8050i com port pin assignment mt6050i /mt8050i pin assignment of the 9 pin, male, pin assignment of the 9 pin, male, sub - d, com1 [rs - 232]/ [r s - 485], com3 [rs - 485] port. only com1[rs485 2w] support mpi 187.5k. pin# symbol com1[rs485] com1[rs232] com3[rs485] 4 wire 2 wire 1 rx - rx - data - 2 rx+ rx+ data+ 3 tx - tx - 4 tx+ tx+ 5 gnd gnd 6 txd transmit 7 data - data - 8 d ata+ data+ 9 rxd receive + - reset dip sw - - - com com cpu pwr cutout dimensions: mt-6050i: 119mm [4.685"] w x 93mm [3.661"] h front view rear view bottom view www.datasheet.net/ datasheet pdf - http://www..co.kr/
plc connection guide 777 wiring d iagram: mt6050i com1 [rs - 232] 9p d - sub female plc rs - 232 communication com port interface 9 rxd txd 6 txd rxd 5 gnd gnd mt6050i com1 [rs - 485 2w] 9p d - sub f emale plc rs - 485 2w communication com port interface 1 data - data - 2 data+ data+ mt6050i com 3* [rs - 485 2w] 9p d - sub female plc rs - 485 2w communication com port interface 7 data - data - 8 data+ data+ *rs485 2w com3 is only available for mt6050iv2 mt6050i com1 [rs - 485 4w] 9p d - sub female plc rs - 485 2w communication com port interface 1 rx - tx - 2 rx tx+ 3 tx - rx - 4 tx+ rx+ www.datasheet.net/ datasheet pdf - http://www..co.kr/


▲Up To Search▲   

 
Price & Availability of KV-10

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X