contactor configuration phase rotation sensor E-326A 1 amp, 115 vac product specifications construction epoxy encapsulated operating voltage and frequency continuous duty, 115 volt, 3 phase, l to n, 60 hz max. input voltage range for normal operation 115 20v operation the phase rotation sensor will apply a dc potential of +28v to any external relay coil or load when the phase rotation is a-b-c and shall remove the +28v signal when phase rotation is other than a-b-c. normal load 1 amp continuous 5 amps intermittent (.020 second maximum) environmental: temperature operating -55 c to +71 c vibration .060 da 5 to 55 hz acceleration 55 - 200 hz log constant weight 4.5 oz. features: ? controls external relay ? epoxy encapsulated ? 115 vac, 60 hz, 3? operation ? 1 amp ? high reliability ? meets many requirements of mil-r-6106 ? light weight construction notes: catalog ( we b d oc o nl y ) dimensions are in inches and dimensions are shown for usa: 1-800-522-6752 south america: 55-11-3611-1514 revised 5 -04 millimeters unless otherwise reference purposes only. canada: 1-905-470-4425 hong kong: 852-2735-1628 specified. values in brackets specifications subject mexico: 01-800-733-8926 japan: 81-44-844-8013 www.tycoelectronics.com are metric equivalents. to change. c. america: 52-55-5-729-0425 uk: 44-141-810-8967 har t ma n a er o spa ce po wer p ro duct s di men sion s fo r thi s pro du ct a re e xp re ss e d in in ch es . mu l ti pl y val ue s b y 25 .4 f or m ill im et er s . for factory-direct application assistance, con ta ct t h e ha rt ma n p rod uct te am at ( 41 9 ) 52 1 - 95 00 , fa x ( 41 9 ) 5 2 6 - 27 4 9 . ?200 4 by tyco electronics corporation. all rights reserved. ha rt ma n and tyco are trademarks.
|