Part Number Hot Search : 
0S080H FQP1P50 BCR8P KSP2222A M66509 BU95408 2815T 120N1T
Product Description
Full Text Search
 

To Download EDS10-79C Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
  paperless recorder overview this is a paperless recorder that displays measured data on the lcd in real time and stores data in compactflash. the type of input such as thermocouple, resistance bulb, d.c. voltage (current), etc. can be arbitrarily set to 36 chan - nels at the maximum. the data stored in compactflash can be regenerated on the screen, and the use of supplied support software allows the data to be regenerated on a pc screen. the data recorded in ascii format can be directly read in a spreadsheet such as excel, which facilitates the process - ing on a pc. (the data recorded in binary format cannot be read in.) features 1. large capacity storage by compactflash measured data is periodically stored in compactflash. in case of 512 mb, for example, display fles for about 2 year and a half (display refresh cycle 30 sec) can be taken up (in case of ascii data format, 9 channels, maximum/ minimum recording). 2. quick search and display of past data data stored in compactflash can be displayed in succes - sion by scrolling the screen. 3. various display capability depending on the object of measurement, the most suitable display format can be selected from a variety of formats including bar graph display, trend display, digital display, etc. 4. pc support software supplied as standard loader software that enables easy display and change of set data and data viewer software that regenerates the data stored in compactflash are supplied as standard. 5. 36-point recording 12 types of thermocouples, 2 types of resistance bulbs and dc voltage/current input can be recorded up to 36 points. 6. lcd extinguishing function automatically extinguishes the lcd if nothing is operated for certain time. you can set the time after a lapse of which the lcd is extinguished via parameter "lcd ex - tinguishing time". the settable range is 0 to 60 minutes. setting at 0 minute overrides the function, whereby the lcd will never extinguish. this function prevents the backlight life from shortening uselessly. during the extinguishment, the power con - sumption can be reduced. 7. ethernet function (option) ftp, web server, e-mail and modbus-tcp are available using 10base-t. specifications input system number of input points: 9, 18, 27 or 36 points (can be selected at the time of purchase) input circuit: input mutual isolation (see others on page 4 for the withstand voltage) resistance bulb measured current: about. 1 ma measuring cycles: 9 or 18 points.100ms cycles 27 or 36 points.200ms cycles recording cycle: 1 second to 12 hours input types: thermocouple, resistance bulb, dc voltage, and dc current (shunt resistors are ftted in input terminals). note) provide a shunt resistor (type: phzp0101) separately. measuring range input types reference range thermocouple b r s k e j t n w l u pn 400.0 to 1760.0c 0.0 to 1760.0c 0.0 to 1760.0c C200.0 to 1370.0c C200.0 to 800.0c C200.0 to 1100.0c C200.0 to 400.0c 0.0 to 1300.0c 0.0 to 1760.0c C200.0 to 900.0c C200.0 to 400.0c 0.0 to 1300.0c resistance bulb jpt100 pt100 ni100 pt50 cu50 C200.0 to 600.0c C200.0 to 600.0c C60.0 to 180.0c C200.0 to 600.0c C50.0 to 200.0c dc voltage 50mv 500mv 1-5v 0-5v 0.00 to 50.00mv 0.0 to 500.0mv 1.000 to 5.000v 0.000 to 5.000v note) b, r, s, k, e, j, t, n : u : cu-cu ni (din 43710) jis c 1602, din iec 584-1 pn: platinel w : 5%re-26%re w jpt100 : jis c 1604- 1989 (old jis pt 100) (hoskins mfg. co. usa) pt100, pt50 : jis 1604, din iec 751 l : fe-cu ni (din 43710) data sheet phu EDS10-79C dec. 5, 2011 date
2 phu selection of input types: by key operation on the front panel. note that the same input type (thermocouple, resistance bulb, voltage) should be set ev - ery 2 channels. refer to "setting method of input types" for details. burn-out function: provided as standard for thermocouple and resistance bulb inputs. if the input has been open-circuited, the recording level swings over 100%. thermocouple burn-out current: approx. 0.2 a input flter function: settable for each channel (primary delay flter) time constants are settable in the range from 0 to 900 sec. scaling function: possible by dc voltage (current) input scaling range: -32767 to 32767 decimal position: settable at any point unit symbol: selectable out of 125 dif - ferent units or 12 user units of up to 7 charac - ters. subtraction function: subtraction between each channel is allowed. totalizing function: the measured value of each channel can be totalized. applicable to daily, monthly, annual or external input total - izing. f value calculation function: f value (extinction value of bacteria by sterilization by heating) can be calcu - lated from the measured temperature by each channel. square rooter function: square rooter can be performed against the input value per each chan - nel. computation function: the following calculation is available with the computation function. (1) computation function: addition, subtraction, multiplication, division, absolute value, exponential, square-root extraction, log, ln, exp, humidity, maximum, minimum, aver - age, and integration. (2) computation input enable: analog input (ch1 to 72), integration input (ch1 to 72), di (di1 to 16), com - munication input (no.1 to 36), and constant number (no.1 to 60). indication system indicator: 12 tft color lcd (800 x 600 dots) with backlight, no contrast adjustment. on the lcd, certain picture elements remain lit or extinguished. on account of the nature inherent to lcd, the brightness may be non-uniform. but, such are not troubles. color of indication: 14 colors applicable language: english, french (switchable) life of backlight: 50,000 hours in terms of total lighting time. (replace the backlight as a set of display unit. if the lcd extinguishing function is resorted to, the lcd can be used longer as much.) trend display: direction: vertical and horizontal number of channels: 10, 6 or 4 channels per screen group. (input: 72 points at the maximum). display refreshment cycles: select from 1 second to 12 hours scale display or no-display can be se - lected. bar graph display: number of channels: 10, 6 or 4 channels per screen group. (input: 72 points at the maximum). display refreshment cycles: 1 second analog meter display: number of channels: 10, 6 or 4 channels per screen group. display in bar graphs or in analog meters can be selected. display refresh cycle: 1 second digital display: number of channels: 10, 6 or 4 chan - nels per screen group. (input: 72 points at the maximum). display refreshment cycles: 1 second totalizing data display: number of channels: 10, 6 or 4 channels per screen group. (input: 72 points at the maximum). display refresh cycle: 1 second event summary display: alarm summary and message summary can be displayed. the message occur - rence information and message display can be switched. ethernet log display: e-mail sending, ftp server log in/off and modbus tcp/ip communication start/ stop can be displayed. parameter display/set: already-set data display and set change display screen tag indication: number of characters to be displayed: up to 8 characters up to 8 characters (note 1) at 10 or 6 channel display. up to 16 characters at 4 channel dis - play. note 1: up to 7 characters only can be displayed on certain screens. characters to be displayed: alphanumerics tag , unit and channel no. display: which can be displayed depends on the particular screen. refer to the table below. (keywords only are extracted.)
3 screen channnels per screen item tag 1 tag 2 unit ch np. trend bar graph analog meter instantaneous value 4 or less 5, 6 7 or more 6 or less 7 or more ? ? ? ? ? ? ? ? ? all all all C C C ? : displayed ? : 1 item only can be displayed C : nothing can be displayed historical trend display: displays past recording data read from compact fash, currently recording data or just recorded data. the recording chart can be scrolled or, via time designation, the control can jump to an arbitrary recording chart. number of screen groups: 8 groups (up to 10 channels per 1 group can be registered.) keyboard no. of keys: 8 function: use to select various screens and set various parameters. recording function external memory media: compact flash card format according to fat16 or fat. oth - erwise, reading and saving are impos - sible. recording capacity: 1 gb maximum (compact fash). limiting the recording fle to 64 mb is recom - mended (for 112 hours if display refresh cycle is 1 second. see table 1 (p. 6).) if impossible, up to 256 mb is toler - ated. a fle recorded beyond could not be opened. * please change the compact fash every six month to prevent the data losing. recording method: turning on the rec key allows measured data to be written at fxed cycles. recorded as a new fle whenever the recording starts. data save cycles: linked to the display refreshment cycles on the real time trend screen. how - ever, they are automatically set to about 1 minute if the refreshment cycles are set to less than 1 minute. trend data: measurement data sampled at mea - surement cycle is saved in terms of mean value, instantaneous value or maximum/minimum value. event data: saves alarm data and message data. further saves power on and off, if any, after starting recording. totalizing value data: tot alizing value dat a at designat - ed timing is recorded per channel. totalized value data at designated total - ized value recording cycle or the sum total is recorded in the totalizing fle. you can choose which type you want to record. for each cahnnel. it can be select as totalizing action from analog input to - talization, digital input count or period of digital input on, and it can be se - lect as totalizing period type from dairy, weekly, monthly, annual, periodic, dairy (time set) or external input signal. even if a power failure occues during total - ization and then the power is restored,the totalization restarts from the value before power failure. confguration data: confguration data can be saved. and this data can also download to recorder. storage capacity : approximately 3 years when the display refresh cycle is 30 seconds (in case of 9-channel recording in ascii data format, and 512 mb compact fash used). refer to table 1. residual capacity of memory: indicates how much of the memory card has been used on the screen. if the residual capacity is none, the recording stops. compact fash card form: phzp2801 (cf card) (if a card other than the above is used, no operation assurance is ensured. meanwhile, as for other cf cards for which operation check will have been completed, the results will be posted on our company's homepage sequentially. please refer to this website.) data format: either of ascii or binary format can be selected. (switching cannot be made while the recording is in progress. in the case of ascii format, the data can be directly read on excel, etc. the data recorded in binary format cannot be read directly.) approximately 166 bytes per sampling for maximum/minimum recording of 9-channel input in ascii format, or approximately 40 bytes for maximum/ minimum recording of 9-channel input in binary format. alarm function no. of settings: up to 4 alarms for each channel are set - table. type of alarm: high/low limits indication: status (alarm types) is displayed on digital display unit when an alarm oc - curs. historical display on alarm summary (alarm start/cancel time and alarm types)
4 phu hysteresis: set within the recording range of 0 to 100% acts on high or low limit alarm, and does not affect the battery alarm nor memory full alarm. relay output: number of points; 20 (option: up to 2 cards with relay output can be mount - ed.) transistor output (open collector output): 16 points (option) alarm latch function: holds alarm indication and alarm output even after measurement value has left the alarm range. on/off operation is performed according to key setting. power supply rated power voltage: 100 to 240v ac range of operating voltage: 90 to 264v ac supply frequency: 50/60hz 2% (both employable) power consumption power voltage 100v ac 240v ac consumption about 65va about 80va structure mounting method: panel-mounted (vertical panel) thickness of panel: 2 to 26 mm materials: stainless steel for case, pc-abs for bezel color: silver for case, munsell n2.0 (black) for bezel external dimensions: 300 (w) 300 (h) 220.5 (d) mm mass: about 4.7 kg (9-point input, without op - tion) about 6.4 kg (full option) external terminal board: input terminal: m3 screw terminal power terminal: m4 screw terminal operating condition power supply voltage: 90 to 264v ac power supply frequency: 50/60hz 2% (sharing) ambient temperature: without ethernet function: 0 to 50c * 1 with ethernet function: 0 to 40c * 2 ambient humidity: 20 to 80%rh vibration: 10 to 60hz 0.2m/s 2 or less shock: none magnetic feld: 400 a/m or less signal source resistance: thermocouple input . 1k ? or less resistance bulb input . 10 ? /wire or less (resistance of each wire of 3-wire system should be balanced). voltage input . 0.1% or less of input resistance mounting posture: forward tilt 0, backward tilt within 30, horizontal 0 warm-up time: one hour or more after power on *1: in case of the 12th digit of ordering code is y. *2: in case of the 12th digit of ordering code is e. reference standard accuracy/resolution: measuring conditions (23 2?c, 65 10% rh, power voltage, frequency fuctuation within 1%, no external noise, warm-up time of 1 hour or more, vertical mount - ing, standard values of signal source resistance and wiring resistance... within 1% ) input types digital indication accuracy note 1 digital indication resolution thermocouple b r s k e j t n w l u pn (0.15%+1 digit) (0.3%+1 digit) for the range shown below thermocouple b : 400 to 600c thermocouples r and s : 0 to 300c thermocouples k, e, j, t, l and u : - 200 to - 100c resistance bulb jpt100 pt100 pt50 (0.15%+1 digit) (0.5%+1 digit) dc voltage 50mv 500mv 5v (0.15%+1 digit) 0.1c 10v 100v 1mv note 1) digital indication accuracy is a percentage (%) with respect to input range of 1 page. note 2) no error of reference contact compensation of thermocouple is included. ni100 cu50 0.1c error of reference contact compensation: k, e, j, t, n, l, u, pn: 0.5?c r, s, b, w: 1.0?c (when measured at 0?c or more) max. input voltage: thermocouple, resistance bulb, dc voltage: 10v dc (continuous) input impedance: thermocouple, dc voltage: about 1m ? others clock: with calendar function (christian era) accuracy: 50 ppm or less (monthly error: about 2 minutes) however, time error at power on/off is not included.
5 memory backup: parameters are saved to the internal non-volatile fash memory. the clock is backed up with built-in lithium battery. trend data is not backed up. insulation resistance: 100 m ? (when measured between each terminal and ground by using a 500v dc megger) withstand voltage: input terminal C input terminal: 500 v ac, 1 min power terminal C ground: 2000v ac, 1 min input terminal C ground:500v ac, 1 min alarm terminal (cont act output) C ground: 2000 v ac, 1 min alarm terminal (contact output) C alarm terminal (contact output): 750 v ac, 1 min communication terminal C ground: 500 v ac, 1 min a la r m t e r m in a l ( o p e n c o ll e c t o r ) C ground: 500 v ac, 1 min power terminal C input terminal: 500 v ac, 1 min effect on operation effect of power supply fuctuation conditions: for the fuctuation in the range from 90 to 264v ac (frequeucy: 50/60hz) reading change: (0.2%+1 digit) or lower. for the fuctuation in the range from 47 to 63hz (power voltage: 100v ac) reading change: (0.2%+1 digit) or lower. effect of input signal resistance: thermocouple input: 50 v 1 digit per 100 ? dc voltage: fluctuation for resistance value equivalent to 0.1% of the input resistance: (0.2%+1 digit) or lower. reistance bulb (for wiring resistance of 10 ? for 1 line (the same for 3 lines)) reading change: (0.2%+1 digit) or lower. effect of ambient temperature: reading change: (0.3%+1 digit)/10?c or lower. effect of mounting position: for the backward 30? slant reading change: (0.2%+1 digit) or lower. effect of vibration: when sine wave of 10 to 60hz with the acceleration of 0.2m/s 2 is applied in each direction for 2 hours. reading change: (0.2%+1 digit) or lower. safety and emc standard safety standard: based on iec61010-1 emc standard: based on en61326 transportation/storage conditions temperature: -10 to +60?c humidity: 5 to 90%rh vibration: 10 to 60hz, 2.45 m/s 2 or lower shock: 294m/s 2 or lower (packed state) additional function (option) alarm relay output (11th digit of code symbols: 1, 2, 4 or 5) up to 2 cards with 10-point relay output can be mounted. (maximum 20 points) terminal structure: m3 screw terminal alarm relay output: 1a contact output (10 points/card), individual channel or common output (or output) allowed. rating: contact capacity 240v ac/3a, 30v dc/3a (resistive load). alarm open collector output (11 digit of code symbols is 3, 4 or 5) card having 16 alarm points (open collector output) can be mounted. terminal structure: m3 screw terminal alarm output: open-collector transistor output (16 points) rating: 30v dc/0.1a (resistance load) di input (7 digits of code symbol is 1) card having 16 di input can be mounted. terminal structure: m3 screw terminal di input: no-voltage contact input (16 points). contact input allows following controls. (1) recording start/stop (2) message set (3) f value calculation reset (4) totalizing start/stop (5) totalized value reset (6) lcd (backlight) lighting (7) e-mail sending input pulse width: on pulse width: 400msec or more off pulse width: 400msec or more ethernet (option) the following can be performed through the ethernet function. http server (internet explorer 6 is available) note 1 measurement display: digitally displays the measurement of each channel of the recorder and alarm occurrence status. event summary display: displays event summary including alarm on/off and issuance of messages. main unit information display: displays memory use conditions and information on the main unit such as the battery end warning. integrated value display: digitally displays the integrated value of each channel of the recorder. ftp server (internet explorer 6 available.) note 1 file download: record fles stored in compact fash (cf) can be downloaded from the browser.
6 phu file delete: record fles stored in cf can be deleted from the browser. access authentication: authenticates access authority to ftp server. smtp (e-mail client) transmits e-mails to specifed address under the following conditions. (1) when an alarm turns on or off (2) when di is set to on or off (3) when an error occurs to the main unit (such as low battery or no memory space) (4) at specifed intervals modbus tc/ip data read: settings can be read through modbus tcp/ip communication. data write: settings can be written through mod - bus tcp/ip communication. note1: neither netscape nor mozilla firefox are available. support software the following software is provided as standard. ? applicable pc: pc/at-compatible machine ? operation on pc98-series machines by nec is not guar - anteed. ? operation on self-made or shop-brand pcs is not guaran - teed. loader software for pc major function: performs various parameter setting/ change of the main unit o/s: windows 2000/xp (windows vista is not supported.) required memory: 64mb or larger disk drive: windows 2000/xp-capable cd-rom hard disk capacity: free capacity of 30mb or larger re - quired printer: windows 2000/xp-capable printer and printer driver note) pc loader communication cable (type phzp1801) is separately required. data viewer software major function: regenerates the past trend record on the pc from the data in the compact fash. provided with historical trend display and event display functions. data can be changed to csv fle. o/s: windows 2000/xp (windows vista is not supported.) required memory: 64mb or larger disk drive: windows 2000/xp-capable cd-rom drive hard disk drive: free capacity of 30mb or larger re - quired printer: windows 2000/xp-capable printer and printer driver standard functions function record range voluntary setting input type setting skip function trend display tag name display screen name display unit creation scaling function pv shift input filter burnout function historical trend display description recording range can be set by channel. input type can be set by channel. (key operation on the front face) set the same input type for every 2 channels. skips arbitrary channel display/recording. time display: time is displayed at the top of the trend display screen. alarm display: on occurrence of an alarm and the restoration, alarm is displayed in the alarm display field. the compact flash usage is displayed with a bargraph at the top. by channel, maximum of 8 characters. displays the screen name (maximum of 16 characters). industrial units can be arbitrarily created, maximum of 7 digits, 12 types. arbitrary scaling is allowed in the case of dc voltage input. decimal point position can also be arbitrarily set in the range from -32767 to 32767. shift the zero point and slant of the reading. prevents sudden fluctuation of input for each channel (primary delay filter). time constant: 0 to 900 seconds. displays the break of thermocouple/resistance bulb input by scaling out to 100% side. regenerates and displays the data stored in the compact flash by scrolling the screen. displays data of a designated time. table 1. recording capacity the recording can be made for the period of time listed in the tables shown below under the following condi - tions. ? 9 input points ? recording data format: ascii ? recording type: maximum/minimum recording ? no alarm, nor message, nor other events. display upgrade cycle compactflash size 64mb 1 sec 10 sec 30 sec 1 min 10 min recordable capacity (about) 112 hours 46 days 140 days 280 days 7.7 years display upgrade cycle compactflash size 256mb 1 sec 10 sec 30 sec 1 min recordable capacity(about) 18 days 187 days 1.5 years 3 years ? when the number of input points goes on increasing, the period becomes as follows. 18 input points; the period is approximately one half of those listed in the table. 27 input points; the period is approximately one-third of those listed in the table. 36 input points; the period is approximately one-fourth of those listed in the table. ? in binary format, the period is approximately 4 times as long as those listed in the table. ? for recording type of mean or instantaneous value, the number of days is approximately 2 times as long. when compact fash is not used, up to 6m bytes of the recording data and the event data can be stored in the main unit. (in case of 32-channel in max./min. recording, approximately 400,000 data can be stored. for 11 hours at the display refresh cycle of 1 second. the number of the save data varies depending on the number of the event data.
7 code symbols specifications 4 5 6 7 8 0 0 1 phu 4 7 8 9 11 12 1 2 3 4 - e 0 1 2 3 4 5 9 points 18 points 27 points 36 points without with (16 points) english without 10 relay points 20 relay points transistor (open collector) 16 points 10 relay points + transistor (open collector) 16 points 20 relay points + transistor (open collector) 16 points without with 9 10 11 12 13 1 y digit note 0 1 1 y e scope of deliviry recorder item quantity panel mounting bracket cd-rom pc support software instruction manual 1 2 1 noise filter for the power supply 1 optional items pc card adapter phzp0501 for compact flash compact flash phzp2801-512 phzp2801-01g 512mb 1gb item code specification shunt resistor for dc current input phzp0101 10 0.1% pc loader communication cable phzp1801 length 3m with connector usb-a/usb minib terminal * cd-rom with instruction manual and support software phzp2501 * shape of this cable is shown below usb (a) male C usb (mini-b ) male b
8 phu outline diagrams (unit : mm) panel mounting type in the case of 9-point input r-module rcj ch9 ch8 + tc?^v + ch6 + tc?^v 17 16 - lower oi 18 27 24 25 - 26 ch1 3 tc?^v 1 2 - + tc?^v + 4 ch4 12 upper 15 ?i + tc?^v 13 14 - ch5 6 + ch2 7 tc?^v 5 11 - 8 - 10 9 + ch3 tc?^v ch7 21 - tc?^v 19 20 - tc?^v 22 23 rcj + di di do32 do24 ch1-ch9 ?itr?j do21-36 do31 do22 vpd vpd do21 do29 do23 do30 pcd do36 do35 do34 do27 do28 do26 do25 do33 pcd di4 di12 lan communicator di11 di3 di2 di10 di1 0v di 0v di9 0v di8 di16 di14 di7 di13 di6 di15 di5 di1-16 di 0v do15 do15 do14 do11 do12 do13 ?iry?j do11-20 do1-10 ?iry?j do13 do11 do12 do14 do19 do20 do18 do17 do16 do20 do18 do19 do17 do16 do5 do5 do4 do2 do3 do1 do1 do2 do4 do3 do10 do9 do8 do7 do8 do9 do7 do6 do6 do10 n l 100-240vac?` push 300 280 220.5 175 26 280 318 300 input terminal (1 to 9 points) t mounting bracket panel power terminal di input terminal alarm output relay terminal alarm output transistor terminal ethernet terminal (option) 2 t 26 in the case of 18-point input r-module rcj r-module rcj ch9 ch8 + tc?^v + ch6 + tc?^v 17 16 - lower oi 18 27 24 25 - 26 ch1 3 tc?^v 1 2 - + tc?^v + 4 ch4 12 upper 15 ?i + tc?^v 13 14 - ch5 ch18 tc?^v tc?^v + ch17 ch16 rcj + tc?^v + + tc?^v ch15 43 - 44 oi lower 48 - 46 45 47 49 - 50 54 - 53 52 51 tc?^v ch10 - 29 28 tc?^v + + 33 ch11 34 - 32 31 tc?^v 30 + - 38 39 ch13 + - 37 36 35 ch12 tc?^v ?i 42 upper - 41 40 tc?^v + ch14 6 + ch2 7 tc?^v 5 11 - 8 - 10 9 + ch3 tc?^v ch7 21 - tc?^v 19 20 - tc?^v 22 23 rcj + di di do32 do24 ch1-ch9 ?itr?j do21-36 do31 do22 vpd vpd do21 do29 do23 do30 pcd do36 do35 do34 do27 do28 do26 do25 do33 pcd di4 di12 ch10-ch18 lan communicator di11 di3 di2 di10 di1 0v di 0v di9 0v di8 di16 di14 di7 di13 di6 di15 di5 di1-16 di 0v do15 do15 do14 do11 do12 do13 ?iry?j do11-20 do1-10 ?iry?j do13 do11 do12 do14 do19 do20 do18 do17 do16 do20 do18 do19 do17 do16 do5 do5 do4 do2 do3 do1 do1 do2 do4 do3 do10 do9 do8 do7 do8 do9 do7 do6 do6 do10 n l 100-240vac?` push 300 280 220.5 175 26 280 318 300 input terminal (1 to 9 points) mounting bracket input terminal (10 to 18 points) power terminal di input terminal alarm output relay terminal alarm output transistor terminal ethernet terminal (option) t panel 2 t 26
9 in the case of 27-point input r-module r-module rcj rcj r-module rcj ch9 ch8 + tc?^v + ch6 + tc?^v 30 ch10 29 tc?^v + 28 43 - 44 - tc?^v + oi lower 33 ch16 48 + ch11 34 tc?^v ch15 45 - 32 + 31 tc?^v 46 - tc?^v + 47 17 16 - lower oi 18 ch17 - 38 tc?^v 49 39 50 - ch13 35 - 37 rcj 36 + ch12 + tc?^v ?i 42 ch18 54 upper 51 + - tc?^v 41 + 40 53 52 - tc?^v ch14 27 24 25 - 26 ch1 3 tc?^v 1 2 - + tc?^v + 4 ch4 12 upper 15 ?i + tc?^v 13 14 - ch5 ch18 tc?^v tc?^v + ch17 ch16 rcj + tc?^v + + tc?^v ch15 43 - 44 oi lower 48 - 46 45 47 49 - 50 54 - 53 52 51 tc?^v ch10 - 29 28 tc?^v + + 33 ch11 34 - 32 31 tc?^v 30 + - 38 39 ch13 + - 37 36 35 ch12 tc?^v ?i 42 upper - 41 40 tc?^v + ch14 6 + ch2 7 tc?^v 5 11 - 8 - 10 9 + ch3 tc?^v ch7 21 - tc?^v 19 20 - tc?^v 22 23 rcj + di di ch19-ch27 do32 do24 ch1-ch9 ?itr?j do21-36 do31 do22 vpd vpd do21 do29 do23 do30 pcd do36 do35 do34 do27 do28 do26 do25 do33 pcd di4 di12 ch10-ch18 lan communicator di11 di3 di2 di10 di1 0v di 0v di9 0v di8 di16 di14 di7 di13 di6 di15 di5 di1-16 di 0v do15 do15 do14 do11 do12 do13 ?iry?j do11-20 do1-10 ?iry?j do13 do11 do12 do14 do19 do20 do18 do17 do16 do20 do18 do19 do17 do16 do5 do5 do4 do2 do3 do1 do1 do2 do4 do3 do10 do9 do8 do7 do8 do9 do7 do6 do6 do10 n l 100-240vac?` push 300 280 220.5 175 26 280 318 300 input terminal (1 to 9 points) input terminal (19 to 27 points) input terminal (10 to 18 points) power terminal di input terminal alarm output relay terminal alarm output transistor terminal ethernet terminal (option) t mounting bracket panel 2 t 26 in the case of 36-point input r-module r-module r-module rcj rcj r-module rcj rcj ch9 ch8 + tc?^v + ch6 + tc?^v 30 ch10 29 tc?^v + 28 43 - 44 - tc?^v + oi lower 33 ch16 48 + ch11 34 tc?^v ch15 45 - 32 + 31 tc?^v 46 - tc?^v + 47 17 16 - lower oi 18 ch17 - 38 tc?^v 49 39 50 - ch13 35 - 37 rcj 36 + ch12 + tc?^v ?i 42 ch18 54 upper 51 + - tc?^v 41 + 40 53 52 - tc?^v ch14 27 24 25 - 26 ch1 3 tc?^v 1 2 - + tc?^v + 4 ch4 12 upper 15 ?i + tc?^v 13 14 - ch5 ch18 tc?^v tc?^v + ch17 ch16 rcj + tc?^v + + tc?^v ch15 tc?^v ch28 98 - tc?^v 82 + tc?^v 97 - 83 + lower oi 88 ch29 87 + 102 ch34 + tc?^v 100 tc?^v ch33 99 84 85 + 86 - - 101 43 - 44 oi lower 48 - 46 45 47 ch35 ch31 104 93 tc?^v 103 92 - - 91 ch30 + 89 rcj 90 - tc?^v + upper ch36 96 108 ?i 107 tc?^v + 105 94 + tc?^v 106 95 - - ch32 49 - 50 54 - 53 52 51 tc?^v ch10 - 29 28 tc?^v + + 33 ch11 34 - 32 31 tc?^v 30 + - 38 39 ch13 + - 37 36 35 ch12 tc?^v ?i 42 upper - 41 40 tc?^v + ch14 6 + ch2 7 tc?^v 5 11 - 8 - 10 9 + ch3 tc?^v ch7 21 - tc?^v 19 20 - tc?^v 22 23 rcj + di di ch19-ch27 do32 do24 ch1-ch9 ?itr?j do21-36 do31 do22 vpd vpd do21 do29 do23 do30 pcd do36 do35 do34 do27 do28 do26 do25 do33 pcd ch28-ch36 di4 di12 ch10-ch18 lan communicator di11 di3 di2 di10 di1 0v di 0v di9 0v di8 di16 di14 di7 di13 di6 di15 di5 di1-16 di 0v do15 do15 do14 do11 do12 do13 ?iry?j do11-20 do1-10 ?iry?j do13 do11 do12 do14 do19 do20 do18 do17 do16 do20 do18 do19 do17 do16 do5 do5 do4 do2 do3 do1 do1 do2 do4 do3 do10 do9 do8 do7 do8 do9 do7 do6 do6 do10 n l 100-240vac?` push 300 280 220.5 175 26 280 318 300 input terminal (1 to 9 points) input terminal (19 to 27 points) input terminal (28 to 36 points) input terminal (10 to 18 points) power terminal di input terminal alarm output relay terminal alarm output transistor terminal ethernet terminal (option) t mounting bracket panel 2 t 26 p anel cutout si z e 281 +2 0 320 min 281 +2 0 360 min
10 phu external connection diagrams m4 screw power terminal 100 to 240v ac 50/60hz m3 screw alarm output relay terminal do1 1 11 do2 2 12 do3 3 13 do4 4 14 do5 5 15 do6 6 16 do7 7 17 do8 8 18 do9 9 19 do10 10 20 m3 screw alarm output relay terminal do11 21 31 do12 22 32 do13 23 33 do14 24 34 do15 25 35 do16 26 36 do17 27 37 do18 28 38 do19 29 39 do20 30 40 m3 screw alarm output transistor terminal vpd 41 51 do21 42 24v dc+ 52 do22 43 53 do23 44 54 do24 45 55 do25 46 56 do26 47 57 do27 48 58 do28 do29 do30 do31 do32 do33 do34 do35 do36 0v 49 59 pcd 50 60 m3 screw di input terminal di 0v 61 71 di1 62 72 di2 63 73 di3 64 74 di4 65 75 di5 66 76 di6 67 77 di7 68 78 di8 di9 di10 di11 di12 di13 di14 di15 di16 69 79 di 0v 70 80 input terminal note) for current input, connect an optional shunt resistance to a voltage input terminal. m3 screw number of input points = 1 to 9 points number of input points = 10 to 18 points number of input points = 19 to 27 points number of input points = 28 to 36 points ch6 ch7 rcj ch8 ch9 + + - - + + - - + + - - + + - - + + - - + + - - + + - - + + - - + + - - ch1 ch2 ch3 ch4 ch5 ch15 ch16 rcj ch17 ch18 + + - - + + - - + + - - + + - - + + - - + + - - + + - - + + - - + + - - ch10 ch11 ch12 ch13 ch14 resistance bulb resistance bulb thermocouple thermocouple voltage voltage resistance bulb thermocouple voltage resistance bulb thermocouple voltage resistance bulb resistance bulb thermocouple thermocouple voltage voltage resistance bulb thermocouple voltage resistance bulb thermocouple voltage 16 1 17 2 18 3 19 4 20 5 21 6 7 8 9 22 10 23 11 24 12 25 13 26 14 27 15 43 28 44 29 45 30 46 31 47 32 48 33 34 35 36 49 37 50 38 51 39 52 40 53 41 54 42 ch24 ch25 rcj ch26 ch27 + + - - + + - - + + - - + + - - + + - - + + - - + + - - + + - - + + - - ch19 ch20 ch21 ch22 ch23 ch33 ch34 rcj ch35 ch36 + + - - + + - - + + - - + + - - + + - - + + - - + + - - + + - - + + - - ch28 ch29 ch30 ch31 ch32 70 55 71 56 72 57 73 58 74 59 75 60 61 62 63 76 64 77 65 78 66 79 67 80 68 81 69 97 82 98 83 99 84 100 85 101 86 102 87 88 89 90 103 91 104 92 105 93 106 94 107 95 108 96
11 s electing input type the input type is the same every 2 channels. the input type of channel 2, 4, 6, 8, 11, 13, 15, 17, 20, 22, 24, 26, 29, 31, 33 and 35 can only be set in the same category of previous channel. note, however, that input type can be arbitrarily selected only for channels 9, 18, 27 and 36 irrespective of the type allocated to other channels. the following input types are available. details input type thermocouple, 50mv resistance bulb pt100, jpt100, ni100, pt50 and cu50 k, e, j, t, r, s, b, n, w, l, u, and pn thermocouples, 50mv 500mv 500mv 5v 1 to 5v, 0 to 5v example of channel input type selection (for 18 points input) input type description input type channel 1 k thermocouple thermocouple, 50mv the type of thermocouple can be arbitrarily selected for each channel. channel 2 t thermocouple channel 3 1-5v 5v channel 4 0-5v channel 5 channel 6 channel 7 channel 8 channel 9 channel 10 channel 11 channel 12 channel 13 channel 14 channel 15 channel 16 channel 17 channel 18 pt100 resistance bulb the type of resistance bulb can be arbitrarily selected for each channel. jpt100 500mv 500mv 500mv j thermocouple thermocouple, 50mv input type can be arbitrarily selected for channel 9. k thermocouple 50mv thermocouple, 50mv the input type of the thermocouple and 50mv is the same. skip 1-5v 5v skip and other channel can arbitrarily be selected irrespective of the input type. pt100 skip resistance bulb other channels 500mv 500mv thermocouple, 50mv input type can be arbitrarily selected for channel 18. 50mv note 1) windows2000/xp, excel, and internet explorer are the trademarks or registered trademarks of microsoft corpora - tion in the u.s. note 2) compactflash is the trademark or registered trademark of sandisk corporation. note 3) modbus is the trademark or registered trademark of aeg schneider automation international. note 4) the pc98 series are the trademark or registered trademark of nec corporation. note 5) netscape is the trademark or registered trademark of netscape communications corp. note 6) firefox is the trade mark of mozilla corporation.
phu printed in japan caution on safety *before using this product, be sure to read its instruction manual in advance. international sales div sales group gate city ohsaki, east t ower , 1 1-2, osaki 1-chome, shinagawa-ku, t okyo 141-0032, japan http://www .fujielectric.com phone: 81-3-5435-7280, 7281 fax: 81-3-5435-7425 http://www .fjielectric.com/products/instruments/ information in this catalog is subject to change without notice.


▲Up To Search▲   

 
Price & Availability of EDS10-79C

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X