Part Number Hot Search : 
HFB1N70S SFAF3L ZXLD1356 3BR1765 BIC703M F1505XS F1505XS DM0365R
Product Description
Full Text Search
 

To Download RCE-95 Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
  gamewell-fci 12 clintonville road, northford, ct 06472-1610 usa ? tel: (203) 484-7161 ? fax: (203) 484-7118 specifications are for information only, are not intended for installation purposes, and are subject to change without notice. no responsibility is assumed by gamewell-fci for their use. ?2007 honeywell international inc. all rights reserved. www.gamewell-fci.com cs-2045 rev. a page 1 of 2 RCE-95 relay control elements description the gamewell-fci relay control element (RCE-95) is the interface between the gamewell-fci 600 series fire alarm control panel (facp) analog circuits and building functions such as door holders, elevators, dampers, motors and disconnects. the RCE-95 offers feedback input points for positive confirmation of the controlled device?s activity. the RCE-95 works with all 600 series analog addressable facps. for annunciation and feed- back at the panel, gamewell-fci offers a relay control display (rcd). the rcd is only available with the if632 and if650 facps. the RCE-95 is either surface or flush mounted and has an integral led which annunciates upon device activation. operation the devices connect to the slc circuit of the facp via a two-wire non- polarized circuit. in its quiescent mode, the RCE-95 monitors its internal circuitry for status of the device itself and supervises an external control circuit for status. when a status change is detected, the event can be pro- grammed to display on the optional rcd module. when an event is reported to the control panel that requires the activation of the RCE-95, the control panel communicates via the analog circuit to the RCE-95 for activation. the integral led is also lit for annunciation at the device. programming the RCE-95 is programmed by setting a single dip switch easily accessible on the RCE-95?s printed circuit board. the dip switch is used to set the address of the device. all other programming is accomplished at the fire alarm con- trol panel, either through a laptop computer or the control panel operator?s display. features ? compatible with the gamewell-fci 600 series analog addressable facps. ? form-c dry relay contacts. ? event or manual controllable relay functions. ? positive feedback of relay activation. ? led annunciates activation. ? fully supervised. ? surface or flush mounting. ? field programmable. ? style 4, 6 , or 7 wiring. ? screw terminals for field wiring connections. microsoft ? windows ? is a registered trademark of microsoft ? corporation. cs-2054ph1.wmf RCE-95 an iso 9000-2000 company approved fm signaling s521 7300-1288:147
gamewell-fci 12 clintonville road, northford, ct 06472-1610 usa ? tel: (203) 484-7161 ? fax: (203) 484-7118 cs-2045 rev. a page 2 of 2 www.gamewell-fci.com mounting the RCE-95 is designed to mount in a standard 4.688" (11.908 cm) electrical backbox. the RCE-95 should be mounted in an easily visible location so that the built-in led may be seen for quick indication of proper connection and activation. engineer?s specifications a programmable interface device shall be provided for the control and status reporting of programmed relay control functions. the RCE-95 shall communicate with the fire alarm control panel via an analog circuit (slc) over a sin- gle pair of wires. the device shall provide dry contacts and positive feed- back of the controlled equipment?s status annunciating upon activation. it shall be gamewell-fci RCE-95. specifications input power: 24 vdc from analog circuit standby current: 0.0005 a alarm current: 0.0015 a operating temperature: 0 c to 49c (32f to 120f) relative humidity: 85% non-condensing housing requirements: 4.688" (11.908 cm) backbox contact rating: 2.0 amp at 30 vdc 0.2 a at 120 vac ordering information model description RCE-95 relay control element device. xp95 protocol compatible. 70839 trim ring for flush mounting the RCE-95. rcd optional relay control display; provides annunciation of the RCE-95 control element devices at the facp. one needed for every eight rces. compatible only with the if632 and if650 facps


▲Up To Search▲   

 
Price & Availability of RCE-95

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X