an a log input/output module [ pum v/ n / t ] pumv/n/t is usable analog i/o module as the accessory i/o of pum series. each control module, 30mm wide, is equipped the follows. pumv is equipped 4 points of analog input/output. pumn is equipped 4points of analog input. pumt is equipped 4points of analog output. and all models are equipped high-speed rs-485 port. by connecting with pum control modules, it realizes a compact and high-per- formance system. f e a tu r e s i. u ser-friendly structure and functions 1 . l ateral connection with control module: max.16 units (64 channels) + event input/output module 16 units = total 32 units s imple wiring for power supply and communication 2 . d etachable structure: terminal block, main unit, and the base part easy wiring with detachable terminal blcok main units exchangeable without re-wiring 3 . s tatus led for each input/output easy to detect input status and output status 4 . s mart loader communication: connect one module and all connected modules are able to communicate using a loader software. ii. l arge scale system using high speed rs-485 1 . m odbus rtu protocol for large volume communica- tion 2 . h igh-speed communication: maximum 115.2kbps 3 . h ighly-effcient communication: parameters dispersed on the address map are re-allocated to contiguous address iii. v arious functions to enhance the control module func- tions 1 . a nalog input - remote sv 2 . a nalog output - control output (included distribution output) - re-transmission output pum series multi-loop module type temperature controller pumv/n/t data sheet EDS11-169A apr. 1, 2011 date sys tem s pe c i f i ca tion 1. p roduct type: m ulti-loop module type temperature controller 2. m odule type 1) a nalog module: t otal maximum 16 units a) c ontrol module (4 loop/unit) b) e nhanced input/output (analog) module - a nalog input/output module (input/output 4 points/unit) - a nalog input module (input 4 points/unit) - a nalog output module (output 4 points/unit) 2) e nhanced input/output (digital) module: maximum 16 units - e vent input/output module (input/output ; 8 points/unit) 3) enhanced communication module: 1 unit 3. c onnecting method: lateral connecting with connectors - f or power supply and rs-485 communication, any one of connected modules is required to be connected. 4. n o. of loop, input/output 1) c ontrol loop: m ax. 64 2) n o.of input / output: di 128 points / do 128 points
pumv/n/t 2 analog i/o module specification 1. general speci cation (1) power supply: 24v dc ?0% (2) power consumption: max. 3.2 w (135 ma) [when 24v dc is applied] (3) insulation resistance: 20m or more (500v dc) (4) withstand voltage: power supply ? all terminals 1000v ac 1 min. others 500v ac 1 min. (5) applied standards: ul, c-ul, ce marking, rohs directive [pending for ul, c-ul marking] 2. input (pumv, pumn only) (1) no. of input: 4 points (4 ch) (2) input setting: input code selection (3) input signal: see table 1 select from group i or ii depending on the model code. (setting can be done by points within group) [group i] a) thermocouple b) resistance bulb (3 wire) [group ii] c) dc voltage, current (4) measurement range and input type: see table 1 (5) measurement accuracy (ta = 23?): - thermocouple: ?.3%fs?digit?? or ?? whichever is greater * unless b thermocouple 0 to 400? :?%fs?digit?? r thermocouple 0 to 500? :?%fs?digit?? t thermocouple -200 to 0? :?.5%fs?digit?? - resistance bulb input :?.3%fs?digit?? whichever is greater - voltage/current input :?.3%fs?digit (6) resolution: see table 1 (7) temperature uctuation: ?.3%fs?0? (8) input sampling cycle: 200ms (9) input impedance: - thermocouple: 1m or more - current input: 250 - voltage input: approx. 1 m (10) in uence of signal source resistance: - thermocouple: ?.3%fs?digit/100 - voltage input: ?.3%fs?digit/500 (11) allowable wiring resistance: - resistance bulb: 10 or less (per wire) (12) allowable input voltage: - dc voltage input :within ?5v - current input :within ?5ma - thermocouple/resistance bulb: within ?v (13) noise rejection ratio: - normal mode : 30db or more (50/60hz) - common mode : 120db or more (50/60hz) between process value input and earth, power supply, output 220v ac, 50/60hz (14) input compensation: a) user adjustment :zero point, span point ?0%fs b) input value :?0%fs c) first order lag lter :0.0 to 120.0 sec. (15) over range, under range: out of range of -5 to 105%fs (accuracy cannot be ensured for -5 to 0, 100 to 105% fs) (16) insulation: functional insulation between channels, and with any other input/output 3. output (pumv, punt only) (1) no. of output: 4 points (2) output type: current output (4-20ma dc, 0-20ma dc) - actual output range: 0ma to 20.6ma dc - accuracy: ?.3%fs (less than 1ma : ?%fs) - linearity : ?.3%fs (less than 1ma : ?%fs) - resolution: 5,000 or more - ripple current: p-p 0.3ma or less - load resistance: 300 or less - insulation: no insulation between outputs functional insulation other then output (3) output functions: output limit, output scaling 4. communication function 4.1 rs-485 interface (1) communication standards: rs-485 compatible (2) no. of port: 1 port (3) communication, synchro method: two-wire, half-duplex, asynchronous cycle (4) communication speed: 9.6k, 19.2k, 38.4k, 115.2kbps (5) communication distance: 1km (38.4kbps or less), 250m (115.2kbps) (6) recommended cable: kpev-sb 0.5sq-equivalent (7) no. of connectable units: 33 units (master and slave) (32 units if any modules other than pum series are included in slaves.) (8) data format: data bit; 8, parity; even / odd / none (9) protocol: modbus rtu compatible (10) insulation: no insulation with loader communication port functional insulation with any other in- put / output 4.2 loader communication (rs-232c) interface (1) communication standards: rs-232c compatible (2) no. of port: 1 port (3) communication, synchro method: half-duplex, asynchronous cycle (4) communication speed: 19.2kbps ( xed) (5) data format: data bit 8, no parity (6) protocol: modbus rtu compatible (7) connection method: 2.5 diameter mini-plug / jack [on the front of the module] (common cable with pxg, pxh) (8) insulation: no insulation with rs-485 communication functional insulation with any other in- put / output 3 5. display, con guration 5.1 display (1) display: status display led (2 colors ?6 points) (2) display contents: run/fault, rs-485 tx/rx, out/err by loop (4 loops) (functions are assigned to led of each channel) 5.2 setting device (1) setting device: rotary sw ?1 (2) set contents: rs-485 station no. (station no.= setting value + 1) 6. power outage (1) impact of power outage: outage of 2ms or less ; no impact (2) operation after power outage: start from the rst step (cold start) (3) memory backup: non volatile memory (eeprom) no. of update ; 100,000 7. self diagnosis diagnosis method: program error monitoring by watch dog timer 8. structure (1) installation method: din rail mounting or mounting with m3 screws inside a cabinet (2) dimensions: 30 (w) ?100 (h) ?85 (d) mm (excluding terminal cover and projected part) (3) weight: approx. 200 g (4) extrenal terminal - process value input/control output: detachable terminal block (m3 screw ?20 terminals) - power supply connection: terminal block on the base part (m3 screw ?2 terminals) power is supplied via side connectors in case of lateral connecting. (max. 33 units) - rs-485 communication connection: terminal block on the base part (m3 screw ?3 terminals) rs-485 communication is connected via side connectors in case of lateral con- necting. - loader communication port: 2.5 diameter 3 prong mini-plug / jack [on the front of the module] (5) case material: polyphenylene oxide ( ame retardant grade : ul94v-0 equiva- lent) (6) case color: case ; red terminal, base part ; black (7) protection - body: ip20 grade protection (ventilation slits on the top and the bot- tom of the body) - terminal: ip00 grade protection, terminal cover is available as an option 9. normal operating condition (1) ambient temperature*: -10 to 50? * ambient temperature?is the tempera- ture underneath the controller inside the equpiment or the cabinet where the controller is installed. (2) ambient humidity: 90% rh or less (non condensing) (3) vibration: 10 to 70hz, 9.8m/s 2 (1g) or less (4) warmup time: 30 min. or more 10. transporting, storage condition (packing con- dition) (1) storage temperature: -20? to 60? (2) ambient humidity: 90%rh or less (no condensing) (3) vibration: 10 to 70hz, 9.8m/s 2 (1g) or less (4) shock: 294m/s 2 (30g) or less 11. packing list -temperature controller: 1unit -instruction manual: 1 copy -250 resistance: 0, 2, or 4 (for no. points of voltage/current input selected) 12. loader software (1) distribution medium: free download from fuji electric sys- tems hp (http://www. c-net.jp/eng/index. html) (2) recommended operating environment pc: dos/v (pc-at compatible) os: windows xp (operating confirmed in japanese / english) ram: 256m bytes or more free space on the hardware: 500m bytes or more display resolution: 1024 ?768 dots or more serial interface: rs-232c 1 port (without rs-232c, usb serial converter cable required) (3) connection with pum via loader interface on the front face of the module (special cable available from fuji is required) or via rs-485 pumv/n/t 4 code symbols [analog input/ouput module] [analog input module] [table 1] input type and standard input range description 4 5 10 v t a c a b < module type > analog i/o module [ai/ao 4 points] ? * o q v u u z q f? thermocouple/resistance bulb [all channel] voltage/current [all channel] thermocouple/resistance bulb [ch 1, 2], voltage/current [ch3, 4] ? 0 q f s b u j p o n b o v b m? japanease english digit 45678 9 10 123 pum ee digit 10 11 000 12 13 description 4 5 10 n t a c a b < module type > analog input module[ai 4 points] ? * o q v u u z q f? thermocouple/resistance bulb [all channel] voltage/current [all channel] thermocouple/resistance bulb [ch 1, 2], voltage/current [ch3, 4] ? 0 q f s b u j p o n b o v b m? japanease english digit 45678 9 10 123 pum yy digit 10 11 000 12 13 input type input code measurement range [c] min. measurement unit [c] resistance bulb (iec) thermocouple dc voltage j k ?1999 to 9999 (scaling range) 0 to 400 0.1 0 to 400 0 to 1600 0.1 1 dc0to5v r 0 to 1800 1 b 0 to 1600 1 s ?199 to 400 0.1 t ?199 to 800 0.1 e 0 to 1300 1 n dc1to5v dc0to10v dc2to10v 0 to 1300 1 pl- pt100 7 0 to 150 0.1 ?150 to 300 0.1 3 ?150 to 850 1 4 2 5 0 to 800 0.1 6 21 7 0 to 800 0.1 8 0 to 1200 1 9 10 11 12 13 14 18 22 23 24 19 [analog output module] description 4 10 t a b < module type > analog output module[ao 4 points] ? 0 q f s b u j p o n b o v b m? japanease english digit 45678 9 10 123 pum e ye digit 10 11 000 12 13 [accesories (optional)] % f t d s j q u j p o 6 7 8 a a a a l 0 0 0 0 0 1 2 3 4 1 rs-485 terminating resistance din rail mounting endplate side connecting terminal cover (right & left 1 set) fron face screw terminal cover loader connecting cable (rs-232c) digit 45678 123 pumz * digit [table 2] insulation block diagram loader communication port rs-485 communication port power pv1 pv2 pv3 pv4 out1 (current) out2 (current) out3 (current) out4 (current) functional insulation (1000v ac) functional insulation (500v ac) 5 outline diagram (unit : mm) terminal block (at attach/detach) dimensions for screw mounting 30 9 0.2 2-m3 100 88.5 0.2 3 30 +0.7 +0.2 please keep the distance of 30mm from this instrument to radiate. [50mm is recommended] notice at the installation 30 p s n p s f 30 p s n p s f station loader 30 front terminal cover (option) (10) 30 100 5 at mounting to the din rail 8 6.1 terminal screw m3 1. 5 6 85 50 din rail terminal screw m3 main unit (at attach/detach) locking tab hole for screw mounting hole for screw mounting base part (main unit is detached) pumv/n/t 6 terminal connection diagram (analog i/o module [pumv]) thermocouple rtd volt./current* 14 13 15 14 13 15 b b a 14 13 15 19 18 20 19 18 20 19 18 20 22 21 23 22 21 23 22 21 23 27 26 28 27 26 28 27 26 28 power 2 1 communication rs485 a(+) 3 sg 4 b(?) 5 24v dc b b a thermocouple rtd a b b ? + ? + ? + ? + ? + ? + ? + ? + ? ? + + ? + volt./current* rtd thermocouple a b b rtd thermocouple volt./current* volt./current* current current current current station loader 11 12 22 21 13 14 15 16 17 18 19 20 23 24 25 26 27 28 29 30 input 1 output 1 output 2 output 3 output 4 input 2 input 3 input 4 12 345 base part 1 2 3 gnd rx tx loader interface plug (rs-232c) 2.5 3-pole miniature plug * in case of current input, attach i/v unit which comes with controller to the voltage input terminal. 11 12 24 25 29 30 16 17 7 thermocouple rtd volt./current* 14 13 15 14 13 15 b b a 14 13 15 19 18 20 19 18 20 19 18 20 22 21 23 22 21 23 22 21 23 27 26 28 27 26 28 27 26 28 power 2 1 communication rs485 a( + ) 3 sg 4 b( ? ) 5 24v dc b b a thermocouple rtd a b b ? + ? + ? + volt./current* rtd thermocouple a b b volt./current* station loader 11 12 22 21 13 14 15 16 17 18 19 20 23 24 25 26 27 28 29 30 input 1 input 2 input 3 input 4 12 345 base part 1 2 3 gnd rx tx loader interface plug (rs-232c) 2.5 3-pole miniature plug +? 11 12 don? connect 24 25 29 30 16 17 don? connect don? connect volt./current* rtd thermocouple don? connect * in case of currenet input, attach i/v unit which comes with the controller to the voltage input terminal. ? + ? + ? + ? + ? + terminal connection diagram (analog input module [pumn]) pume printed in japan caution on safety *before using this product, be sure to read its instruction manual in advance. international sales div sales group gate city ohsaki, east tower, 11-2, osaki 1-chome, shinagawa-ku, tokyo 141-0032, japan http://www.fujielectric.com phone: 81-3-5435-7280, 7281 fax: 81-3-5435-7425 http://www.fjielectric.com/products/instruments/ information in this catalog is subject to change without notice. t e r min a l c onne c tion di a g ra m (analog output module [pumt]) power 2 1 communication rs485 a( + ) 3 sg 4 b( ? ) 5 24v dc station loader 11 12 22 21 13 14 15 16 17 18 19 20 23 24 25 26 27 28 29 30 1 2 3 4 5 base part 1 2 3 gnd rx tx loader interface plug (rs-232c) 2.5 3-pole miniature plug + ? 14 13 15 19 18 20 22 21 23 27 26 28 dont connect dont connect dont connect dont connect 11 12 current 24 25 29 30 ? + ? + ? + ? + current current 16 17 current output 1 output 2 output 3 output 4 |
Price & Availability of EDS11-169A
![]() |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |