Part Number Hot Search : 
BD9775FV S25VB100 1772188 30CPQ10 AS8223 LVA47A MBT555 P300J
Product Description
Full Text Search
 

To Download PBH20W-70-1MM1O Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
  10 145 algonquin parkway, whippany, nj 07981 ?973-560-0019 ?fax: 973-560-0076 e-mail: filtersales@powerdynamics.com www.powerdynamics.com power line filter specifications subject to change without notice. dimensions (mm). see appendix a for recommended power cord. see pdi full line catalog for detailed specifications on power cords. 16/20a high current, snap-in/flange mount filter with iec 60320 ac inlet socket. pbh series mechanical dimensions features the pbh series offers filters for application that have high current (16/20a) requirements. the filters are available with different configurations of components and termination styles. these filters are available in flange mount and snap-in type. the medical graded filters offer excellent performance with maximum leakage current of 2? at 120vac, 60hz. a ground choke can be added to enhance the grounding ability of the circuit. bleeder resistor can also be added to prevent excessive voltages from developing across the filter capacitors when there is no load. applications computer & networking equipment, measuring & control equipment, data processing equipment, laboratory instruments, switching power supplies, other electronic equipment. technical data rated voltage: 115/250vac rated current: 16a, 20a power line frequency: 50/60hz max. leakage current each line to ground: @ 115vac 60hz: 0.25ma @ 250vac 50hz: 0.50ma @ 115vac 60hz: 2 a* @ 250vac 50hz: 5 a* hipot rating (one minute) line to ground: 2250vdc line to line: 1450vdc temperature range: -25c to +85c (unit: mm) ? semko, vde approved to 16a * medical application 2x 3.6 52.8 42.0 30.1 42.0 35.0 r3 typ. 27.0 2x 4 2x m3 30.0 43.0 52.0 recommended panel cutout (mounting from rear) r3.0 43.0 + - - 0.1 34.5 + 0.5 10.0 + - - 0.1 6.0 + - - 0.1 26.5 + - - 0.5 2x 4.0 27.0 36.0 r3 typ. recommended panel cutout (mounting from front) 0.8 26.0 3.8 27.6 6.35 (79.5) 67.4 0.8 26.2 3.6 34.0 0.8 26.5 -- -- -- -- max 6.35 79.5 75.7 34.5 max -- -- -- -- 38.0 30.0 6.35 (79.5) 67.4 34.0 case f case u case o ?
11 145 algonquin parkway, whippany, nj 07981 ?973-560-0019 ?fax: 973-560-0076 e-mail: filtersales@powerdynamics.com www.powerdynamics.com current rating (a): = 16 = 20 terminal: = q = s = w pbh options: = 00 = 60 = 70 = 80 = 90 quick connect solder wire - - no bleeder resistor & no ground choke bleeder resistor (1/2 w, 1m) bleeder resistor (1/4 w, 1m) & ground choke bleeder resistor (1/2 w, 1m) & ground choke ground choke (100 h) component locations: = 1 = 2 ? = 3 ? = 1m = 2m ? standard type without c(x); c(y) only c(x) & c(y) behind l without c(y); c(x) only without c(y); c(x) behind l pbh series example & ordering code 6.3/0.25 4.0/0.187 ul 1015, 18awg stranded, 4 16 q 50 1 c schematics medical schematics 1 8.0 3.0 -3.6l 0.8mm ab 6.6 .8mm 2.0 -3.0l case code: = f = u = o flange mount snap-in tabs - side rear panel mount u ? contact pdi for attenuation numbers attenuation code table: case code cap. cx (f) 16/20a (mh) f,o,u 0.01 0.5 f,o,u 0.33 0.5 medical applications, select attenuation code with corresponding component values from the table. non-medical applications, select attenuation code with corresponding component values from the table. case code cap. cx (f) cap. cy (pf) 16/20a (mh) f,o,u 0.01 2200 0.5 f,o,u 0.01 3300 0.5 f,o,u 0.33 2200 0.5 = a = b = c = m1 = m2 attenuation comm. mode(l-g) in mhz diff. mode(l-l) in mhz code .15 .5 1 5 10 30 .15 .5 1 5 10 30 a 17 22 26 43 51 43 8 18 24 45 43 35 b 17 23 28 47 57 45 8 18 23 51 54 34 c 17 222643 5143 182833465335 attenuation comm. mode(l-g) in mhz diff. mode(l-l) in mhz code .15 .5 1 5 10 30 .15 .5 1 5 10 30 m1 16 21 22 24 25 20 8 18 25 42 43 30 m2 16 20 22 24 25 20 17 28 33 41 40 31 ? this table applies to schematic 1 only. visit our website or contact pdi for other schematic attenuation numbers. ? this table applies to schematic 1m only. visit our website or contact pdi for other schematic attenuation numbers. medical applications non-medical applications ? ? 1m 2m 3 2 insertion loss in db (50 ohm circuit) insertion loss in db (50 ohm circuit) g g line load l mh l mh l n l l n lg r c x c x g line load l mh l mh cy l n l l n g lg cy r g line load l mh l mh cy l n l l n g cy r g line load l mh l mh l n l l n g lg r cy cy c x g c x g line load l mh l mh l n l l n lg r


▲Up To Search▲   

 
Price & Availability of PBH20W-70-1MM1O

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X