engineering data sheet t412 time delay relay 2 pdt, 10 amp applicable socket: s400 sc40* time delay relay on operate or on release fixed or adjustable timing delay contact arrangement 2 pdt power supply 28 vdc principle technical characteristics contacts rated at 10 amps / 28 vdc weight < 70 grams dimensions of case 44mm x 25.7mm x 26mm max hermetically sealed corrosion protected metal can (mounting flange tin plated) contact electrical characteristics minimum operating cycles contact rating per pole and load type load current in amps @28vdc 100,000 cycles 20,000 cycles 100,000 cycles 100,000 cycles on resistive load on inductive load (l/r=5ms) on motor load on lamp load 10 8 4 2 50 cycles resistive overload 40 numbering system t412 - a e - 1001 - a xxx basic series designation__________________________| | | | | | 1-types of operation (a,b,d,f,u,w)________________________| | | | | 2-temperature range and timing accuracy (e,l,m,j,k,n)_______| | | | 3-timing range (4 digits)________________________________________| | | 4-mounting style and terminal types (a,b,c,d,h,j)[3]____________________| | 5-keying option only with j mounting style__________________________________| featuring leach ? power and control solutions www.esterline.com americas 6900 orangethorpe ave. p.o. box 5032 buena park, ca 90622 . . tel: (01) 714-736-7599 fax: (01) 714-670-1145 europe 2 rue goethe 57430 sarralbe france . . tel: (33) 3 87 97 31 01 fax: (33) 3 87 97 96 86 asia units 602-603 6/f lakeside 1 no.8 science park west avenue phase two, hong kong science park pak shek kok, tai po, n.t. hong kong tel: (852) 2 191 3830 fax: (852) 2 389 5803 data sheets are for initial product selection and comparison. contact esterline power systems prior to choosing a component. date of issue: 3/06 - 53 - page 1 of 4
types of operation t412 temperature range and timing accuracy code temperature accuracy limitations e -55 c to +85 c 10% 10 ms below 200 ms l [4] -55 c to +85 c 5% not below 500 ms m [4] -55 c to +85 c 3% not below 1 s j -55 c to +125 c 10% 10 ms below 200ms k [4] -55 c to +100 c 5% not below 500 ms n [4] -55 c to +100 c 3% not below 1 s d a t e o f i s s u e : 3 / 0 6 - 5 4 - p a g e 2 o f 4 t i m e d e - e n e r g i z e d c o d e u : t i m e d e l a y o n r e l e a s e , a d j u s t a b l e w i t h e x t e r n a l r e s i s t o r c o d e w : t i m e d e l a y o n r e l e a s e , f i x e d t i m e t i m e e n e r g i z e d o u t p u t 2 8 v 0 v p o w e r s u p p l y p o s i t i v e c o n t r o l , f i x e d t i m e p o s i t i v e c o n t r o l , a d j u s t a b l e w i t h c o d e d : t i m e d e l a y o n r e l e a s e , c o d e f : t i m e d e l a y o n r e l e a s e , c o d e a : t i m e d e l a y o n o p e r a t e , c o d e b : t i m e d e l a y o n o p e r a t e , a d j u s t a b l e w i t h e x t e r n a l r e s i s t o r e x t e r n a l r e s i s t o r f i x e d t i m e e n e r g i z e d o u t p u t d e - 2 8 v c o n t r o l 0 v e n e r g i z e d p o w e r s u p p l y d e - e n e r g i z e d t i m e o u t p u t 0 v 2 8 v p o w e r s u p p l y e n e r g i z e d mounting styles and terminal types t412 dimensions in mm tolerances unless otherwise specified 0.25 mm schematic diagram timing range adjustable (for operation code b, f and w) code 1001: 0.1 to 1 second rx = (t / to -1) x 100kohm code 1002: 1 to 10 seconds code 1003: 10 to 100 seconds code 1004: 100 to 1000 seconds where rx in kohms t: desired time in seconds, to: time measured with rx = 0. example to determine rx value for a t time of 5 seconds: choose code 1002; measure time with rx = 0 (for example : to = 1 s); calculate rx = (5/1 - 1) x 100000 theoretical resistance: rx = 400 kohms or fixed the timing code consists of 4 digits. to determine this code, convert the value to milliseconds value. use the first 3 digits of this value and add a fourth digit to indicate the number of zeros which must follow the three digits to show complete milliseconds value. examples: 250 ms --> code 2500 300 s --> code 3003 d a t e o f i s s u e : 3 / 0 6 - 5 5 - p a g e 3 o f 4 s i l i c o n g a s k e t s h o r e a 1 5 - 3 0 4 0 . 5 0 . 1 5 4 1 . 3 0 . 1 7 . 9 m a x 1 5 . 9 h m 3 0 . 2 6 . 9 ? 2 1 5 . 9 2 3 . 8 m a x 3 . 8 2 6 m a x 5 . 0 8 2 5 . 7 m a x a 2 6 m a x 5 . 0 8 1 b 4 4 m a x 3 5 . 5 3 6 . 7 0 . 1 1 . 3 4 0 . 1 5 c 2 3 . 8 m a x 3 . 8 1 1 5 . 9 s i l i c o n g a s k e t s h o r e 2 3 . 8 m a x d 4 4 m a x 3 5 . 5 3 6 . 7 a 1 5 - 3 0 t i n p l a t e d p i n s s o l d e r h o o k s g o l d p l a t e d p i n s s o l d e r h o o k s g o l d p l a t e d p i n s a b c d + x 1 t d 2 3 - x 2 1 r x + x 1 t d - x 2 1 2 r x a b c d 3 t i m e d e l a y o n o p e r a t e o r o n r e l e a s e r x : e x t e r n a l r e s i s t o r p o s i t i v e c o n t r o l v o l t a g e ( c 1 ) t i m e d e l a y o n r e l e a s e w i t h general characteristics t412 operating voltage 18 to 32 vdc (air norm 2021 e) recycle time less than or equal to 50 ms dielectric strength at sea level - all pins connected together and can 1000 v / 50 hz - between open contacts 500 v / 50 hz dielectric strength at altitude 25,000 m, all points 350 v / 50 hz initial insulation resistance at 500 vdc greater than or equal to 1000 m w sinusoidal vibration 20g / 10 to 2000 hz shock 100g / 6 ms power loss protection 0.5 ms max undamaged against positive transients + 80 vdc spike susceptibility 600 vdc self generated spike protection 50 vdc keying options notes 1. relays with c, h mounting are compatible with socket families s 400, sf 400 .. 2. isolation spacer pads for pcb mounting available on request. 3. for other mounting styles or terminal types, please contact the factory. 4. codes l, m, k and n not available for adjustable timing. d a t e o f i s s u e : 3 / 0 6 - 5 6 - p a g e 4 o f 4 + 0 - 0 . 0 8 s i l i c o n g a s k e t s h o r e a 1 5 - 3 0 5 0 . 1 1 . 3 0 . 1 9 0 . 1 5 k e y 2 j 0 . 1 2 3 5 . 7 1 5 . 9 k e y 1 k e y 3 4 - 4 0 u n c 2 b c o d e w 1 2 0 ? c o d e v c o d e u 6 0 ? 0 ? c o d e y c o d e x 1 8 0 ? 2 4 0 ? c o d e z 3 0 0 ? engineering data sheet s400, s401, s402 socket for relays 10 amp basic socket series designation for: series m400 (dc coil), m401 (ac coil), m402 (dc coil), fls402, t402, t412, t441, vs400, cs400 general characteristics crimp tool contact m 22520/1-01 with turret m 22520/1-02 or ms 3191-1. insertion and extraction tool nas 1664-16. weight 35g max. temperature range -70 c to +125 c. this connection is designed to the standards and requirements of mil-s-12883 contacts and hardware to be delivered disassembled in a plastic bag. tolerances, unless otherwise specified, 0.25mm. featuring leach ? power and control solutions www.esterline.com americas 6900 orangethorpe ave. p.o. box 5032 buena park, ca 90622 . . tel: (01) 714-736-7599 fax: (01) 714-670-1145 europe 2 rue goethe 57430 sarralbe france . . tel: (33) 3 87 97 31 01 fax: (33) 3 87 97 96 86 asia units 602-603 6/f lakeside 1 no.8 science park west avenue phase two, hong kong science park pak shek kok, tai po, n.t. hong kong tel: (852) 2 191 3830 fax: (852) 2 389 5803 data sheets are for initial product selection and comparison. contact esterline power systems prior to choosing a component. date of issue: 3/06 - 24 - page 1 of 4 terminal layout s400, s401, s402 mounting hardware d a t e o f i s s u e : 3 / 0 6 - 2 5 - p a g e 2 o f 4 3 5 . 7 2 8 . 2 1 0 . 1 6 1 5 . 2 4 5 . 0 8 x 2 x 1 a d c b 5 . 0 8 1 0 . 1 6 1 5 . 2 4 3 2 1 x 2 a b d c 3 2 x 1 1 a d c x 1 x 2 3 2 1 b 2 6 . 3 1 5 . 9 0 , 1 0 , 3 a x 1 b d c y 2 3 2 x 2 1 y 1 0 . 3 0 . 1 m o u n t i n g h o l e l a y o u t c o d e b s 4 0 1 c o d e c s 4 0 1 c o d e s 4 0 0 c o d e d s 4 0 2 p o s i t i o n , t o l e r a n c e s e e c o d e b p o s i t i o n , t o l e r a n c e s e e c o d e b f o r m 4 0 0 r e l a y f o r m 4 0 2 r e l a y f o r m 4 0 1 r e l a y , f o r k c o i l f o r m 4 0 1 r e l a y , f o r j c o i l f o r h o l e c l e a r a n c e , s e e h a r d w a r e c o d e c o d e 7 : 0 5 - 2 8 4 - 1 5 m e t r i c h a r d w a r e t o p m o u n t m o u n t i n g t o r q u e : 0 , 4 5 0 , 1 n m f o r r e l a y s w i t h c o d e b t e r m i n a l s 1 . 2 m o u n t i n g h o l e : 3 , 6 m m c o d e 6 : 0 5 - 2 8 4 - 1 3 u n c h a r d w a r e b o t t o m m o u n t t o p m o u n t m o u n t i n g t o r q u e : 0 , 4 5 0 , 1 n m m o u n t i n g h o l e : 3 , 6 m m m o u n t i n g h o l e : 3 , 6 m m 1 . 2 1 . 2 c o d e 8 : 0 5 - 2 8 4 - 2 0 l o o s e u n c s t u d s m i l - s - 1 2 8 8 3 / 4 1 - e d i t c b o t t o m m o u n t t o p m o u n t m o u n t i o n g t o r q u e : n u t 4 / 4 0 : 0 , 4 5 0 , 1 n m - n u t 1 0 - 3 2 : 1 , 2 m a x m o u n t i n g h o l e : 5 , 3 m m m o u n t i n g h o l e : 3 , 6 m m 2 . 4 3 . 2 c o d e 9 : 0 5 - 2 8 4 - 2 1 f i x e d u n c s t u d s p e r m i l - s - 1 2 8 8 3 / 4 1 - e d i t c b o t t o m m o u n t t o p m o u n t m o u n t i n g t o r q u e : n u t 4 / 4 0 : 0 , 4 5 0 , 1 n m - n u t 1 0 - 3 2 : 1 , 2 m a x m o u n t i n g h o l e : 5 , 3 m m m o u n t i n g h o l e : 3 , 6 m m m a x 2 . 4 m a x 3 . 2 c o d e 3 : 0 5 - 2 8 4 - 0 7 l o o s e m e t r i c h a r d w a r e t o p m o u n t m o u n t i n g t o r q u e : 0 , 4 5 0 , 1 n m : 3 , 6 m m m a x 4 . 0 c o d e 2 : 0 5 - 2 8 4 - 0 0 l o o s e m e t r i c h a r d w a r e t o p m o u n t m o u n t i n g t o r q u e : 0 , 4 5 0 , 1 n m : 3 , 6 m m 4 . 0 c o d e 1 : 0 5 - 2 8 4 - 1 2 l o o s e u n c h a r d w a r e b o t t o m m o u n t m o u n t i n g t o r q u e n u t 4 / 4 0 : 0 , 4 5 0 , 1 n m n u t 1 0 - 3 2 : 1 , 2 m a x : 3 , 6 m m m a x 2 . 4 wire insulation diameter for seal to grommet s400, s401, s402 code a recommended for contact code 2 contact code 8 diameter: 1.2 ......2.4mm code b recommended for contact code 3 contact code 9 diameter: 0.8 ......1.6mm contact size and style code 2 05 911 00 crimpend to accomodate awg16-18-20 contact mating end #16 code 3 05 911 10 crimpend to accomodate awg20-22-24 contact mating end #16 code 0 without contacts code 8 30 315 00 crimpend to accomodate awg16-18-20 mil-c-39029/92- 533 bin code colour bands or bin code numbering on crimpside contact mating end #16 code 9 30 315 10 crimpend to accomodate awg20-22-24 mil-c-39029/92-534 bin code colour bands or bin code numbering on crimpside contact mating end #16 socket numbering system s400 a 1 a 2 1-basic socket designation________________________| | | | | 2-terminal layout_____________________________________| | | | 3-mounting hardware_______________________________________| | | 4-grommet to seal on wire insulation__________________________| | 5-contact size and style___________________________________________| date of issue: 3/06 - 26 - page 3 of 4 ms/lre cross part no. and mating relays s400, s401, s402 ms - number leach p/n contacts to accomodate wire # applicable for relays mil-s-12883/40 -01 s400-a6a2 16-18-20 loose terminals above/below panel mounting m400-d4a /-l/-n/-b/-c -05 s400-a6b3 20-22-24 -02 s401-b6a2 16-18-20 m 401-d4f/-k -03 n/a n/a n/a -04 s401-c6a2 16-18-20 m 401-d4e/-j ms - number leach p/n contacts to accomodate wire # applicable for relays mil-s-12883/40b -13 s400-a1a2 16-18-20 loose terminals below panel mounting m400-d4a /-l/-n/-b/-c -17 s400-a1b3 20-22-24 -14 s401-b1a2 16-18-20 m 401-d4f/-k -16 s401-c1a2 16-18-20 m 401-d4e/-j ms - number leach p/n contacts to accomodate wire # applicable for relays mil-s-12883/40c -13s s400-a8a8 16-18-20 loose terminals above/below panel mounting m400-d4a /-l/-n/-b/-c -17s s400-a8b9 20-22-24 -14s s401-b8a8 16-18-20 m401-d4f/-k to be determined s401-c8a8 16-18-20 m401-d4e/-j -18s s402-d8a8 16-18-20 m402-d4a/ -l/-n/-b/-c mil-s-12883/40c -19s s400-a9a8 16-18-20 fixed terminals above/below panel mounting m400-d4a /-l/-n/-b/-c -23s s400-a9b9 20-22-24 -20s s401-b9a8 16-18-20 m 401-d4f/-k to be determined s401-c9a8 16-18-20 m 401-d4e/-j -24s s402-d9a8 16-18-20 m 402-d4a/ -l/-n/-b/-c date of issue: 3/06 - 27 - page 4 of 4 engineering data sheet sc30*, sc40* socket for 2 or 4 pole 10 amp 2 pole 4 pole snap and lock socket series designation for: series m300, m301, m302, m400, m401, m402, t402, t412 designed to the standards and requirements of: 2-pole, 10a relays mil-prf-12883/41 mates with m83536, m83726 and ms27709 4-pole, 10a relays mil-prf-12883/40 mates with m83536 features low profile bottom panel mount snaps into panel other models available materials socket body polyetherimide per mil-p-46184 grommet silicone rubber per zz-r-765 hardware stainless steel contacts copper alloy, hard gold plated per mil-g-45204 contact retainers beryllium copper general characteristics insulation resistance 1000 m w min. dielectric withstanding voltage 1500 vrms sea level; 500 vrms at 25,000 m weight 15.3g max. temperature range -65c to +125c vibration mil-std-202, method 204, test condition g shock mil-std-202, method 213, test condition c this socket is designed to snap and lock into a panel to reduce hardware requirement and mounting time. contacts and hardware are provided disassembled in a plastic bag. standard tolerances are .025mm unless otherwise noted. featuring leach ? power and control solutions www.esterline.com americas 6900 orangethorpe ave. p.o. box 5032 buena park, ca 90622 . . tel: (01) 714-736-7599 fax: (01) 714-670-1145 europe 2 rue goethe 57430 sarralbe france . . tel: (33) 3 87 97 31 01 fax: (33) 3 87 97 96 86 asia units 602-603 6/f lakeside 1 no.8 science park west avenue phase two, hong kong science park pak shek kok, tai po, n.t. hong kong tel: (852) 2 191 3830 fax: (852) 2 389 5803 data sheets are for initial product selection and comparison. contact esterline power systems prior to choosing a component. date of issue: 3/06 - 35 - page 1 of 4 socket dimensions sc30* (2 pole) terminal layout d a t e o f i s s u e : 3 / 0 6 - 3 6 - p a g e 2 o f 4 r e l a y m t g s c r e w p h i l l i p s h e a d w a s h e r s p a c e r g a s k e t s u p p l i e d w i t h r e l a y s o c k e t p a n e l . 0 6 4 . 0 0 5 t h i c k w i r e s e a l i n g g r o m m e t 2 9 . 4 6 3 5 . 7 1 4 . 1 4 x r 1 . 4 0 m a x 2 x ? 5 . 0 8 4 3 . 4 3 2 2 . 6 2 7 . 1 8 r e c o m m e n d e d m o u n t i n g p a n e l c u t o u t 5 . 0 2 . 5 4 3 5 . 7 5 . 0 1 3 . 2 1 m a x s c 3 0 1 - 2 s c 3 0 1 - 1 s c 3 0 0 socket dimensions sc40* (4 pole) terminal layout d a t e o f i s s u e : 3 / 0 6 - 3 7 - p a g e 3 o f 4 r e l a y m t g s c r e w p h i l l i p s h e a d w a s h e r s p a c e r g a s k e t s u p p l i e d w i t h r e l a y s o c k e t p a n e l . 0 6 4 . 0 0 5 t h i c k w i r e s e a l i n g g r o m m e t 2 9 . 4 6 3 5 . 7 2 8 . 2 0 m i n 1 5 . 8 4 x r 1 . 4 0 m a x 3 x ? 5 . 0 8 r e c o m m e n d e d m o u n t i n g p a n e l c u t o u t 4 3 . 4 3 2 2 . 6 2 7 . 1 8 5 . 0 8 t y p 2 . 5 4 5 . 0 8 t y p 2 5 . 4 m a x 3 5 . 7 1 5 . 8 s c 4 0 0 s c 4 0 1 - 1 s c 4 0 1 - 2 s c 4 0 2 s c t d x - 1 socket numbering system series sc30* sc 300 01 1-basic socket snap lock designation______________| | || 2-mating relay (m300, m301, m302, m400, m401__________| || 2-hardware (0=less hardware, 1=with hardware)_____________|| 3-contacts (0=less contacts, 1=with contacts)______________| date of issue: 3/06 - 38 - page 4 of 4 |
Price & Availability of T412-WE-1002-D
![]() |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |