ld-p (aldp) times/ min. ordering information types pac king quantity: carton 100 pieces, case 500 pieces note: the ? at the end of the part number only appears on the inner and outer packaging. it does not appear on the relay itsel f. please consult with our sales of?e on a tube packing type. rating 1. coil data 1a 5a slim power relay ld-p relays (aldp) contact arrangement nominal coil voltage part no. 1 form a 5v dc aldp105w 6v dc aldp106w 9v dc aldp109w 12v dc ALDP112W 18v dc aldp118w 24v dc aldp124w nominal coil voltage pick-up voltage (at 20 c 68f) drop-out voltage (at 20 c 68f) nominal operating current [10%] (at 20 c 68f) coil resistance [10%] (at 20 c 68f) nominal operating power max. applied voltage (at 20 c 68f) 5v dc 75%v or less of nominal voltage (initial) 5%v or more of nominal voltage (initial) 40.0ma 125 ? 200mw 130%v of nominal voltage 6v dc 33.3ma 180 ? 9v dc 22.2ma 405 ? 12v dc 16.7ma 720 ? 18v dc 11.1ma 1,620 ? 24v dc 8.3ma 2,880 ? vde compliance with rohs directive features 1. nominal switching capacity: 5a 277v ac 2. ambient temperature: ?0c to +85 c ?0 f to +185 f 3. excellent heat resistance and tracking performance en60695 (gwt2-11, gwf i2-12, gw it2-13) data av ailable (please consult us for details.) 4. slim type: 20.3 (l) 7.0 (w) 15 (h) mm .799 (l) .276 (w) .591 (h) inch typical applications ?boilers ?air conditioner ?refrigerator ?hot water units ?microwave ovens ?fan heaters ld-p relay aldp 1 w nominal coil voltage (dc) 05: 5v, 06: 6v, 09: 9v, 12: 12v, 18: 18v, 24: 24v packing style w: carton packing contact arrangement 1: 1 form a note: certified by ul/c-ul and vde all rights reserved ? copyright panasonic electric works co., ltd.
ld-p (aldp) 2. speci?ations notes: *1. this value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the actual load. *2. wave is standard shock voltage of 1.250s according to jec-212-1981 *3. the upper limit of the ambient temperature is the maximum temperature that can satisfy the coil temperature rise value. refer to usage, transport and storage conditions in notes. reference data characteristics item speci?ations contact arrangement 1 form a contact resistance (initial) max. 100 m ? (by voltage drop 6 v dc 1a) contact material agni type rating nominal switching capacity (resistive load) 5a 277v ac max. switching power (resistive load) 1,385va max. switching voltage 277v ac max. switching current 5a min. switching capacity (reference value)* 1 100ma 5v dc electrical characteristics insulation resistance (initial) min. 1,000m ? (at 500v dc) measurement at same location as ?reakdown voltage section. breakdown voltage (initial) between open contacts 750 vrms for 1 min. (detection current: 10 ma) between contact and coil 4,000 vrms for 1 min. (detection current: 10 ma) surge breakdown voltage* 2 (between contact and coil) (initial) 10,000 v temperature rise (coil) max. 30 c 86f (by resistive method, nominal coil voltage applied to the coil; contact carrying current: 5a, at 85 c 185 f) operate time (at nominal voltage) (at 20 c 68f ) max. 10 ms (excluding contact bounce time.) release time (at nominal voltage) (at 20 c 68f ) max. 10 ms (excluding contact bounce time) (with diode) mechanical characteristics shock resistance functional 300 m/s 2 (half-wave pulse of sine wave: 11 ms; detection time: 10 s.) destructive 1,000 m/s 2 (half-wave pulse of sine wave: 6 ms.) vibration resistance functional 10 to 55 hz at double amplitude of 1.5 mm (detection time: 10 s.) destructive 10 to 55 hz at double amplitude of 1.5 mm expected life mechanical (at 180 times/min.) min. 5 10 6 electrical (at 20 times/min.) min. 2 10 5 (5a 125v ac at rated load), min. 10 5 (5a 250v ac at rated load) conditions conditions for operation, transport and storage* 3 ambient temperature: ?0 c to +85 c ?0 f to +185 f; humidity: 5 to 85% r.h. (not freezing and condensing at low temperature) max. operating speed (at nominal switching capacity) 20 times/min. unit weight approx. 4 g .14 oz 1. max. switching power 2. life curve 3. coil temperature rise sample: aldp112, 6 pcs. point measured: inside the coil contact current: 0 a, 5 a 10 100 10 5 1 0.1 contact voltage, v contact current, a ac resistive load 6543210 100 10 1 contact current, a 125v ac resistive load 250v ac resistive load life, 10 4 5a* 0a* 14012010080 50 40 30 20 10 coil applied voltage, %v temperature rise, c *at room temperature 85c 5a 85c 0a 4-(1). operate time sample: aldp112, 30 pcs. 4-(2). release time (without diode) sample: aldp112, 30 pcs. 4-(3). release time (with diode) sample: aldp112, 30 pcs. max. min. 140 120 100 80 60 10 8 6 4 2 0 coil applied voltage, %v operate time, ms max. min. 140 120 100 80 60 10 8 6 4 2 0 coil applied voltage, %v release time, ms max. min. 140 120 100 80 60 10 8 6 4 2 0 coil applied voltage, %v release time, ms all rights reserved ? copyright panasonic electric works co., ltd.
ld-p (aldp) dimensions (mm inch) safety standards notes for cautions for use. certi?ation authority ul/c-ul 5a 277v ac 70 c 5a 30v dc vde 5a 250v ac cos = 1.0 70 c 5a 30v dc 0ms 5. electrical life test (5a 250v ac resistive load) sample: aldp112, 6 pcs. operation frequency: 20 times/min. (on:off = 1.5s:1.5s) circuit: change of pick-up and drop-out voltage change of contact resistance contact welding detection and mis-contacting detection circuit 250v ac 12v dc max. min. max. min. pick-up and drop-out voltage, v no. of operations, 10 4 drop-out voltage pick-up voltage 100 10 9 8 7 6 5 4 3 2 1 0 max. min. no. of operations, 10 4 10 0 100 90 80 70 60 50 40 30 20 10 0 contact resistance, m ? the cad data of the products with a cad data mark can be downloaded from: http://panasonic-electric-works.net/ac external dimensions 1.15 4.7 .185 .045 max. 7.2 max. 20.5 max. 15.3 max. .602 max. .807 max. .283 0.8 .031 3.4 .134 0.2 .008 0.2 .008 0.4 dia. .016 dia. 1.05 11.5 7.0 .453 .276 .041 0.4 .016 pc board pattern (bottom view) tolerance: 0.1 .004 schematic (bottom view) 11.5 (1.05) (.041) (1.15) (.045) 4.7 .185 .453 7.0 .276 4-1.1 dia. 4-.043 dia. no com coil cad data dimension: less than 1mm .039inch: min. 1mm .039inch less than 3mm .118 inch: min. 3mm .118 inch: gener al toler ance 0.1 .004 0.2 .008 0.3 .012 usage, transport and storage conditions 1) temperature: ?0 to +85 c ?0 to +185 f (?0 to +60 c ?0 to +140 f: relay in the stick) 2) humidity: 5 to 85% rh (avoid freezing and condensation.) the humidity range varies with the temperature. use within the range indicated in the graph below. 3) atmospheric pressure: 86 to 106 kpa temperature and humidity range for usage, transport, and storage certi?ation 1) this relay is ul/c-ul certi?d. ul/c-ul standards: 5 a 277 v ac 70 c 5 a 30 v dc 2) this relay is certi?d by vde. vde standards: 5 a 250 v ac cos = 1.0 70 c 5 a 30 v dc 0ms 3) ul/c-ul and vde certi?d ratings are displayed on the packaging box. (on the relay, only the certi?ation marks are shown and not the certi?d ratings. please refer to the product speci?ation diagrams to see what is stamped.) part number display the ? at the end of the part number only appears on the inner and outer packaging. it does not appear on the relay itself. creepage distance and clearances between contact and coil: min. 6 mm .236 inch 85 5 humidity, %rh tolerance range (avoid condensation when used at temperatures higher than 0c 32f ) (avoid freezing when used at temperatures lower than 0c 32f ) 850?0 +185+32?0 te mperature, c f all rights reserved ? copyright panasonic electric works co., ltd.
|