|
If you can't view the Datasheet, Please click here to try to view without PDF Reader . |
|
Datasheet File OCR Text: |
model r10a-3 r10a-5 r10a-12 r10a-15 r10a-24 max output wattage[w] 6 10 10.8 10.5 12 dc output 3v 2.0a 5v 2.0a 12v 0.9a 15v 0.7a 24v 0.5a specifications model r10a-3 r10a-5 r10a-12 r10a-15 r10a-24 input voltage[v] ac85 - 132 1 f or dc110 - 170 current[a] acin 100v 0.24typ ( io=100% ) frequency[hz] 47 - 440 or dc efficiency[%] 64typ 70typ 75typ 76typ 78typ inrush current[a] acin 100v 20typ ( io=100% )( at cold start ) leakage current[ma] 0.5max ( according to ul , csa and den-an ) output voltage[v] 3 5 121524 current[a] 2.0 2.0 0.9 0.7 0.5 line regulation[mv] 20max 20max 48max 60max 96max load regulation[mv] 40max 40max 100max 120max 150max ripple[mvp-p] 0to+50 c 80max 80max 120max 120max 120max -10-0 c 140max 140max 160max 160max 160max ripple noise[mvp-p] 0to+50 c 120max 120max 150max 150max 150max -10-0 c 160max 160max 180max 180max 180max temperature regulation[mv] 0to+50 c 50max 50max 120max 150max 240max -10 to +50 c 60max 60max 150max 180max 290max drift[mv] * 1 20max 20max 48max 60max 96max start-up time[ms] 100max ( acin 85v , io=100% ) hold-up time[ms] 10typ ( acin 85v , io=100% , 0to+50 c ) 20typ ( acin 100v , io=100% , 0to+50 c ) output voltage adjustment range[v] 2.85 - 3.6 4.5 - 5.5 10.8 - 13.2 13.5 - 16.5 21.6 - 26.4 protection circuit and others overcurrent protection works over 105% of rating and recovers automatically ( acin 100v ) overvoltage protection 4.00v min works over 115% of rating ( by zener diode clamping ) operating indication led ( green ) remote sensing not provided remote on/off not provided isolation input-output ac2 , 000v 1minute , cutoff current = 10ma max , dc500v 50m w min ( at room temperature ) input-fg , cover ac2 , 000v 1minute , cutoff current = 10ma max , dc500v 50m w min ( at room temperature ) output-fg , cover ac500v 1minute , cutoff current = 100ma max , dc500v 50m w min ( at room temperature ) environment operating temp. , humid.and altitude -10 to +60 c , 20 - 90%rh ( non condensing )( refer to derating curve ), 3 , 000m ( 10 , 000feet ) max storage temp. , humid.and altitude -20 to +75 c , 20 - 90%rh ( non condensing ), 9 , 000m ( 30 , 000feet ) max vibration 10 - 55hz , 19.6m/s 2 ( 2g ), 3minutes period , 60minutes each along x , y and z axis impact 196.1m/s 2 ( 20g ), 11ms , once each x , y and z axis safety and noise regulations agency approvals ul60950-1 , c-ul complies with den-an conducted noise complies with fcc-b , vcci-b others case size/weight 26 x 68 x 68mm ( w x h x d ) /150g max ( without cover ) cooling method convection * 1 drift is the change in dc output for an eight hour period after a half-hour warm-up at 25 c , with the input voltage held constant at the rated input/output. * 2 please contact us about safety approvals for the model with option. * avoid prolonged use under over-load. * series/parallel operation with other model is not possible. * derating is required when operated with case cover. r10a ac-dc power supplies enclosed type r 10a -5 - o ordering information 1 series name 2 output wattage 3 output voltage 4 optional * 2 g :low leakage current j :connector type n :with cover r 1234 r r-2
? derating curve ? rise time & fall time (r10a-5) ? overcurrent characteristics (r10a-5) ? static characteristics (r10a-5) v m v p-p output voltage ripple io=100% 4.20 4.40 4.60 4.80 5.00 5.20 0 50 60 70 80 90 100 110 120 130 10 20 30 40 v 60hz acin 100v dc output ac input io=100% 20ms/div please see electric characteristics for shaded ripple, ripple noise. 1 convection 2 1 2 forced air (0.5m 3 /min) v v a 1.0 2.0 3.0 4.0 5.0 6.0 0 1.0 2.0 0 20 40 60 80 100 -10 0 10 20 30 40[30] 50[40] 60[50] 70[60] a output voltage ripple input voltage output voltage output current output voltage ambient temperature inside of means with cover r r-3 r10a external view (mfr : j.s.t.) (mfr : j.s.t.) i/o connector mating connector b3p5 - vh b4p - vh vhr - 5n ? weight : 150g or less (without cover) ? cover is optional ? tolerance : t 1 ? dimensions in mm. connector type barrier strip type terminal + fg cn2 cn1 ac(l) ac(n) - + fg ac( l ) ac(n) - chain: svh-21-p1.1 loose: bvh-21-p1.1 vhr - 4n max (10) m3 cover (13) safety cover 22 (21) voltage adjust led name plate name plate 2 - m3 mounting hole name plate (61) (13.5) 7.5 37 14 22.5 26 3.5 63.5 o 3.5 68 9.5 50 t 0.5 2 - m3 mounting hole 14 68 max 26 t 0.2 36 cn1 cn2 mounting torque: 0.6n ? m(6.3kgf ? cm)max performance data model r15a-3 r15a-5 r15a-9 r15a-12 r15a-15 r15a-18 r15a-24 max output wattage[w] 9 15 15.3 15.6 15 15.3 16.8 dc output 3v 3.0a 5v 3a 9v 1.7a 12v 1.3a 15v 1.0a 18v 0.85a 24v 0.7a specifications model r15a-3 r15a-5 r15a-9 r15a-12 r15a-15 r15a-18 r15a-24 input voltage[v] ac85 - 132 1 f or dc110 - 170 current[a] acin 100v 0.37typ ( io=100% ) frequency[hz] 47 - 440 or dc efficiency[%] 68typ 72typ 73typ 75typ 75typ 76typ 78typ inrush current[a] acin 100v 20typ ( io=100% )( at cold start ) leakage current[ma] 0.5max ( according to ul , csa and den-an ) output voltage[v] 35912151824 current[a] 3.0 3.0 1.7 1.3 1.0 0.85 0.7 line regulation[mv] 20max 20max 36max 48max 60max 72max 96max load regulation[mv] 40max 40max 100max 100max 120max 120max 150max ripple[mvp-p] 0to+50 c 80max 80max 120max 120max 120max 120max 120max -10-0 c 140max 140max 160max 160max 160max 160max 160max ripple noise[mvp-p] 0to+50 c 120max 120max 150max 150max 150max 150max 150max -10-0 c 160max 160max 180max 180max 180max 180max 180max temperature regulation[mv] 0to+50 c 50max 50max 90max 120max 150max 180max 240max -10 to +50 c 60max 60max 120max 150max 180max 200max 290max drift[mv] * 1 20max 20max 36max 48max 60max 72max 96max start-up time[ms] 100max ( acin 85v , io=100% ) hold-up time[ms] 10typ ( acin 85v , io=100% , 0to+50 c ) 20typ ( acin 100v , io=100% , 0to+50 c ) output voltage adjustment range[v] 2.85 - 3.6 4.5 - 5.5 8.1 - 9.9 10.8 - 13.2 13.5 - 16.5 16.2 - 19.8 21.6 - 26.4 protection circuit and others overcurrent protection works over 105% of rating and recovers automatically ( acin 100v ) overvoltage protection 4.00v min works over 115% of rating ( by zener diode clamping ) operating indication led ( green ) remote sensing not provided remote on/off not provided isolation input-output ac2 , 000v 1minute , cutoff current = 10ma max , dc500v 50m w min ( at room temperature ) input-fg , cover ac2 , 000v 1minute , cutoff current = 10ma max , dc500v 50m w min ( at room temperature ) output-fg , cover ac500v 1minute , cutoff current = 100ma max , dc500v 50m w min ( at room temperature ) environment operating temp. , humid.and altitude -10 to +60 c , 20 - 90%rh ( non condensing )( refer to derating curve ), 3 , 000m ( 10 , 000feet ) max storage temp. , humid.and altitude -20 to +75 c , 20 - 90%rh ( non condensing ), 9 , 000m ( 30 , 000feet ) max vibration 10 - 55hz , 19.6m/s 2 ( 2g ), 3minutes period , 60minutes each along x , y and z axis impact 196.1m/s 2 ( 20g ), 11ms , once each x , y and z axis safety and noise regulations agency approvals ul60950-1 , c-ul complies with den-an conducted noise complies with fcc-b , vcci-b others case size/weight 30 x 69 x 84mm ( w x h x d ) / 200g max ( without cover ) cooling method convection * 1 drift is the change in dc output for an eight hour period after a half-hour warm-up at 25 c , with the input voltage held constant at the rated input/output. * 2 please contact us about safety approvals for the model with option. * avoid prolonged use under over-load. * series/parallel operation with other model is not possible. * derating is required when operated with case cover. r15a ac-dc power supplies enclosed type r 15a -5 - o ordering information 1 series name 2 output wattage 3 output voltage 4 optional * 2 c :with coating g :low leakage current j :connector type n :with cover r 1234 r r-4 ? rise time & fall time (r15a-5) ? static characteristics (r15a-5) ? inrush current (r15a-5) ? overcurrent characteristics (r15a-5) v m v p-p output voltage ripple io=100% 4.20 4.40 4.60 4.80 5.00 5.20 0 50 60 70 80 90 100 110 120 130 10 20 30 40 v 60hz output voltage ripple input voltage acin 100v dc output ac input io=100% 20ms/div v a 1.0 2.0 3.0 4.0 5.0 6.0 0 1.0 2.0 3.0 4.0 output voltage output current 10ms/div frequency 60hz load 100% input voltage ac100v 10a/div r r-5 r15a external view (mfr : j.s.t.) i/o connector mating housing b3p5 - vh b4p - vh vhr - 5n ? weight : 200g or less (without cover) ? cover is optional ? tolerance : t 1 ? dimensions in mm. connector type barrier strip type + fg cn2 cn1 ac(l) ac(n) - + fg ac(l) ac(n) - (10) 22 cover m3 name plate voltage adjust 2 - m3 mounting hole 2 - m3 mounting hole name plate 55 t 0.5 3.5 76 84 14 3 5 3.5 18.5 5 1.75 36.5 69 name plate led max safety cover (23.5) (13.5) (63) (61) (13.5) 7.5 9.5 16 25 30 34 74 t 0.5 max vhr - 4n cn1 cn2 (mfr : j.s.t.) terminal chain: svh-21-p1.1 loose: bvh-21-p1.1 mounting torque: 0.6n ? m(6.3kgf ? cm)max performance data model r25a-3 r25a-5 r25a-9 r25a-12 r25a-15 r25a-18 r25a-24 max output wattage[w] 15 25 25.2 25.2 25.5 25.2 26.4 dc output 3v 5.0a 5v 5a 9v 2.8a 12v 2.1a 15v 1.7a 18v 1.4a 24v 1.1a specifications model r25a-3 r25a-5 r25a-9 r25a-12 r25a-15 r25a-18 r25a-24 input voltage[v] ac85 - 132 1 f or dc110 - 170 current[a] acin 100v 0.58typ ( io=100% ) frequency[hz] 47 - 440 or dc efficiency[%] 69typ 73typ 75typ 76typ 76typ 77typ 79typ inrush current[a] acin 100v 20typ ( io=100% )( at cold start ) leakage current[ma] 0.5max ( according to ul , csa and den-an ) output voltage[v] 35912151824 current[a] 5.0 5.0 2.8 2.1 1.7 1.4 1.1 line regulation[mv] 20max 20max 36max 48max 60max 72max 96max load regulation[mv] 40max 40max 100max 100max 120max 120max 150max ripple[mvp-p] 0to+50 c 80max 80max 120max 120max 120max 120max 120max -10-0 c 140max 140max 160max 160max 160max 160max 160max ripple noise[mvp-p] 0to+50 c 120max 120max 150max 150max 150max 150max 150max -10-0 c 160max 160max 180max 180max 180max 180max 180max temperature regulation[mv] 0to+50 c 50max 50max 90max 120max 150max 180max 240max -10 to +50 c 60max 60max 120max 150max 180max 200max 290max drift[mv] * 1 20max 20max 36max 48max 60max 72max 96max start-up time[ms] 200max ( acin 85v , io=100% ) hold-up time[ms] 10typ ( acin 85v , io=100% , 0to+50 c ) 20typ ( acin 100v , io=100% , 0to+50 c ) output voltage adjustment range[v] 2.85 - 3.6 4.5 - 5.5 8.1 - 9.9 10.8 - 13.2 13.5 - 16.5 16.2 - 19.8 21.6 - 26.4 protection circuit and others overcurrent protection works over 105% of rating and recovers automatically ( acin 100v ) overvoltage protection 4.00 - 5.25v works at 115 - 140% of rating operating indication led ( green ) remote sensing not provided remote on/off not provided isolation input-output ac2 , 000v 1minute , cutoff current = 10ma max , dc500v 50m w min ( at room temperature ) input-fg , cover ac2 , 000v 1minute , cutoff current = 10ma max , dc500v 50m w min ( at room temperature ) output-fg , cover ac500v 1minute , cutoff current = 100ma max , dc500v 50m w min ( at room temperature ) environment operating temp. , humid.and altitude -10 to +60 c , 20 - 90%rh ( non condensing )( refer to derating curve ), 3 , 000m ( 10 , 000feet ) max storage temp. , humid.and altitude -20 to +75 c , 20 - 90%rh ( non condensing ), 9 , 000m ( 30 , 000feet ) max vibration 10 - 55hz , 19.6m/s 2 ( 2g ), 3minutes period , 60minutes each along x , y and z axis impact 196.1m/s 2 ( 20g ), 11ms , once each x , y and z axis safety and noise regulations agency approvals ul60950-1 , c-ul complies with den-an conducted noise complies with fcc-b , vcci-b others case size/weight 31 x 69 x 104mm ( w x h x d ) / 250g max ( without cover ) cooling method convection * 1 drift is the change in dc output for an eight hour period after a half-hour warm-up at 25 c , with the input voltage held constant at the rated input/output. * 2 please contact us about safety approvals for the model with option. * avoid prolonged use under over-load. * series/parallel operation with other model is not possible. * derating is required when operated with case cover. r25a ac-dc power supplies enclosed type r 25a -5 - o ordering information 1 series name 2 output wattage 3 output voltage 4 optional * 2 c :with coating g :low leakage current j :connector type n :with cover r 1234 r r-6 ? inrush current (r25a-5) ? rise time & fall time (r25a-5) ? static characteristics (r25a-5) ? overcurrent characteristics (r25a-5) v m v p-p output voltage ripple io=100% 4.20 4.40 4.60 4.80 5.00 5.20 0 50 60 70 80 90 100 110 120 130 10 20 30 40 v 60hz output voltage input voltage ripple acin 100v dc output ac input io=100% 20ms/div v 1.0 2.0 3.0 4.0 5.0 6.0 0 2.0 4.0 6.0 8.0 a output voltage output current 10ms/div 10a/div frequency 60hz load 100% input voltage ac100v r r-7 r25a external view (mfr : j.s.t.) i/o connector mating housing b3p5 - vh b4p - vh vhr - 5n connector type vhr - 4n cn1 cn2 (mfr : j.s.t.) terminal chain: svh-21-p1.1 loose: bvh-21-p1.1 + fg cn2 cn1 ac(l) ac(n) - ? weight : 250g or less (without cover) ? cover is optional ? tolerance : t 1 ? dimensions in mm. barrier strip type + fg ac(l) ac(n) - (10) 22 cover m3 name plate voltage adjust 2 - m3 mounting hole 70 t 0.5 23.5 36.5 69 name plate led max safety cover (23.5) (13.5) (63) (61) (13.5) 7.5 9.5 3 - m3 mounting hole name plate o 3.5 96 104 14 3 3.5 17.5 26 31 35 90 t 0.5 9 83 t 0.5 max mounting torque: 0.6n ? m(6.3kgf ? cm)max performance data model r50a-3 r50a-5 r50a-9 r50a-12 r50a-15 r50a-18 r50a-24 max output wattage[w] 30 50 50.4 50.4 51 50.4 52.8 dc output 3v 10a 5v 10a 9v 5.6a 12v 4.2a 15v 3.4a 18v 2.8a 24v 2.2a specifications model r50a-3 r50a-5 r50a-9 r50a-12 r50a-15 r50a-18 r50a-24 input voltage[v] ac85 - 132 1 f or dc110 - 170 current[a] acin 100v 1.1typ ( io=100% ) frequency[hz] 47 - 440 or dc efficiency[%] 74typ 78typ 79typ 80typ 81typ 82typ 83typ inrush current[a] acin 100v 30typ ( io=100% )( at cold start ) leakage current[ma] 0.5max ( according to ul , csa and den-an ) output voltage[v] 35912151824 current[a] 10 10 5.6 4.2 3.4 2.8 2.2 line regulation[mv] 20max 20max 36max 48max 60max 72max 96max load regulation[mv] 40max 40max 100max 100max 120max 120max 150max ripple[mvp-p] 0to+50 c 80max 80max 120max 120max 120max 120max 120max -10-0 c 140max 140max 160max 160max 160max 160max 160max ripple noise[mvp-p] 0to+50 c 120max 120max 150max 150max 150max 150max 150max -10-0 c 160max 160max 180max 180max 180max 180max 180max temperature regulation[mv] 0to+50 c 50max 50max 90max 120max 150max 180max 240max -10 to +50 c 60max 60max 120max 150max 180max 200max 290max drift[mv] * 1 20max 20max 36max 48max 60max 72max 96max start-up time[ms] 200max ( acin 85v , io=100% ) hold-up time[ms] 10typ ( acin 85v , io=100% , 0to+50 c ) 20typ ( acin 100v , io=100% , 0to+50 c ) output voltage adjustment range[v] 2.85 - 3.6 4.5 - 5.5 8.1 - 9.9 10.8 - 13.2 13.5 - 16.5 16.2 - 19.8 21.6 - 26.4 protection circuit and others overcurrent protection works over 105% of rating and recovers automatically ( acin 100v ) overvoltage protection 4.00 - 5.25v works at 115 - 140% of rating operating indication led ( green ) remote sensing not provided remote on/off not provided isolation input-output ac2 , 000v 1minute , cutoff current = 10ma max , dc500v 50m w min ( at room temperature ) input-fg , cover ac2 , 000v 1minute , cutoff current = 10ma max , dc500v 50m w min ( at room temperature ) output-fg , cover ac500v 1minute , cutoff current = 100ma max , dc500v 50m w min ( at room temperature ) environment operating temp. , humid.and altitude -10 to +60 c , 20 - 90%rh ( non condensing )( refer to derating curve ), 3 , 000m ( 10 , 000feet ) max storage temp. , humid.and altitude -20 to +75 c , 20 - 90%rh ( non condensing ), 9 , 000m ( 30 , 000feet ) max vibration 10 - 55hz , 19.6m/s 2 ( 2g ), 3minutes period , 60minutes each along x , y and z axis impact 196.1m/s 2 ( 20g ), 11ms , once each x , y and z axis safety and noise regulations agency approvals ul60950-1 , c-ul complies with den-an conducted noise complies with fcc-b , vcci-b others case size/weight 33 x 85 x 119mm ( w x h x d ) / 300g max ( without cover ) cooling method convection * 1 drift is the change in dc output for an eight hour period after a half-hour warm-up at 25 c , with the input voltage held constant at the rated input/output. * 2 please contact us about safety approvals for the model with option. * avoid prolonged use under over-load. * parallel operation is not possible. * derating is required when operated with case cover. r50a ac-dc power supplies enclosed type r 50a -5 - o ordering information 1 series name 2 output wattage 3 output voltage 4 optional * 2 c :with coating g :low leakage current j :connector type n :with cover r 1234 r r-8 ? inrush current (r50a-5) ? rise time & fall time (r50a-5) ? static characteristics (r50a-5) ? overcurrent characteristics (r50a-5) v m v p-p output voltage ripple io=100% 4.20 4.40 4.60 4.80 5.00 5.20 5.40 0 50 60 70 80 90 100 110 120 130 30 40 50 60 70 80 20 v 60hz output voltage ripple input voltage acin 100v dc output ac input io=100% 20ms/div v a 1.0 2.0 3.0 4.0 5.0 6.0 0 510 15 output voltage output current 10ms/div 10a/div frequency 60hz load 100% input voltage ac100v r r-9 r50a external view (mfr : j.s.t.) i/o connector mating housing b3p5 - vh b4p - vh vhr - 5n connector type vhr - 4n cn1 cn2 (mfr : j.s.t.) terminal chain: svh-21-p1.1 loose: bvh-21-p1.1 ? weight : 300g or less (without cover) ? cover is optional ? tolerance : t 1 ? dimensions in mm. barrier strip type + fg cn1 ac(l) ac(n) - cn2 + fg ac(l) ac(n) - 17.5 cover m3 name plate voltage adjust 2 - m3 mounting hole 35 name plate led max safety cover (14) (72) (61) (13.5) 7.5 9.5 (10.5) (24) 70 t 0.5 23 85 2 - m3 max mounting hole name plate o 3.5 3 3.5 17.5 30 33 37 14 119 100 t 0.5 111 14 mounting torque: 0.49n?m(5.0kgf?cm)max performance data model r100u-3 r100u-5 r100u-9 r100u-12 r100u-15 r100u-18 r100u-24 max output wattage[w] 60 100 103.5 102 105 100.8 108 dc output 3v 20a 5v 20a 9v 11.5a 12v 8.5a 15v 7a 18v 5.6a 24v 4.5a specifications model r100u-3 r100u-5 r100u-9 r100u-12 r100u-15 r100u-18 r100u-24 input voltage[v] ac85 - 132 1 f or dc110 - 170 current[a] acin 100v 2.8typ ( io=100% ) frequency[hz] 47 - 440 or dc efficiency[%] 75typ 79typ 80typ 82typ 83typ 84typ 85typ inrush current[a] acin 100v 15typ ( io=100% ) leakage current[ma] 0.5max ( 60hz , according to ul , csa and den-an ) output voltage[v] 3 5 9 12151824 current[a] 20 20 11.5 8.5 7 5.6 4.5 line regulation[mv] 20max 20max 36max 48max 60max 72max 96max load regulation[mv] 40max 40max 100max 100max 120max 120max 150max ripple[mvp-p] 0to+50 c 80max 80max 120max 120max 120max 120max 120max -10-0 c 140max 140max 160max 160max 160max 160max 160max ripple noise[mvp-p] 0to+50 c 120max 120max 150max 150max 150max 150max 150max -10-0 c 160max 160max 180max 180max 180max 180max 180max temperature regulation[mv] 0to+50 c 50max 50max 90max 120max 150max 180max 240max -10 to +50 c 60max 60max 120max 150max 180max 200max 290max drift[mv] * 1 20max 20max 36max 48max 60max 72max 96max start-up time[ms] 200max ( acin 85v , io=100% ) hold-up time[ms] 20typ ( acin 100v , io=100% , 0to+50 c ) 10typ ( acin 85v , io=100% , 0to+50 c ) output voltage adjustment range[v] 2.85 - 3.6 4.5 - 5.5 8.1 - 9.9 10.8 - 13.2 13.5 - 16.5 16.2 - 19.8 21.6 - 26.4 protection circuit and others overcurrent protection works over 105% of rating and recovers automatically overvoltage protection 4.00 - 5.25v works at 115 - 140% of rating operating indication led ( green ) remote sensing provided remote on/off not provided isolation input-output ac2 , 000v 1minute , cutoff current = 10ma max , dc500v 50m w min ( at room temperature ) input-fg , cover ac2 , 000v 1minute , cutoff current = 10ma max , dc500v 50m w min ( at room temperature ) output-fg , cover ac500v 1minute , cutoff current = 100ma max , dc500v 50m w min ( at room temperature ) environment operating temp. , humid.and altitude -10 to +60 c , 20 - 90%rh ( non condensing )( refer to derating curve ), 3 , 000m ( 10 , 000feet ) max storage temp. , humid.and altitude -20 to +75 c , 20 - 90%rh ( non condensing ), 9 , 000m ( 30 , 000feet ) max vibration 10 - 55hz , 19.6m/s 2 ( 2g ), 3minutes period , 60minutes each along x , y and z axis impact 196.1m/s 2 ( 20g ), 11ms , once each x , y and z axis safety and noise regulations agency approvals ul60950-1 , csa c22.2 no.60950-1 , en60950-1 complies with den-an and iec60950-1 conducted noise complies with fcc-b , vcci-b others case size/weight 34.5 x 93 x 160mm ( w x h x d ) / 600gmax ( without cover ) cooling method convection * 1 drift is the change in dc output for an eight hour period after a half-hour warm-up at 25 c , with the input voltage held constant at the rated input/output. * 2 please contact us about safety approvals for the model with option. * avoid prolonged use under over-load. * parallel operation with other model is not possible. * derating is required when operated with case cover. r100u ac-dc power supplies enclosed type r 100 u -5 - o ordering information 1 series name 2 output wattage 3 ul recognized,t u v approved,csa certified 4 output voltage 5 optional * 2 c :with coating g :low leakage current n :with cover r 12345 r r-10 ? overcurrent characteristics ( r100u-5 ) ? static characteristics ( r100u-5 ) ? rise time & fall time ( r100u-5 ) ? derating curve r r-11 r100u external view ? weight : 600g or less (without cover) ? cover is optional ? tolerance : t 1 ? dimensions in mm. mounting torque: 1.2n ? m(12.8kgf ? cm)max performance data model r150u-3 r150u-5 r150u-9 r150u-12 r150u-15 r150u-18 r150u-24 max output wattage[w] 90 150 153 156 150 153 156 dc output 3v 30a 5v 30a 9v 17a 12v 13a 15v 10a 18v 8.5a 24v 6.5a specifications model r150u-3 r150u-5 r150u-9 r150u-12 r150u-15 r150u-18 r150u-24 input voltage[v] ac85 - 132 1 f or dc110 - 170 current[a] acin 100v 4.2typ ( io=100% ) frequency[hz] 47 - 440 or dc efficiency[%] 74typ 78typ 79typ 80typ 82typ 83typ 84typ inrush current[a] acin 100v 15typ ( io=100% ) leakage current[ma] 0.5max ( 60hz , according to ul , csa and den-an ) output voltage[v] 3 5 9 12151824 current[a] 30 30 17 13 10 8.5 6.5 line regulation[mv] 20max 20max 36max 48max 60max 72max 96max load regulation[mv] 40max 40max 100max 100max 120max 120max 150max ripple[mvp-p] 0to+50 c 80max 80max 120max 120max 120max 120max 120max -10-0 c 140max 140max 160max 160max 160max 160max 160max ripple noise[mvp-p] 0to+50 c 120max 120max 150max 150max 150max 150max 150max -10-0 c 160max 160max 180max 180max 180max 180max 180max temperature regulation[mv] 0to+50 c 50max 50max 90max 120max 150max 180max 240max -10 to +50 c 60max 60max 120max 150max 180max 200max 290max drift[mv] * 1 20max 20max 36max 48max 60max 72max 96max start-up time[ms] 200max ( acin 85v , io=100% ) hold-up time[ms] 20typ ( acin 100v , io=100% , 0to+50 c ) 10typ ( acin 85v , io=100% , 0to+50 c ) output voltage adjustment range[v] 2.85 - 3.6 4.5 - 5.5 8.1 - 9.9 10.8 - 13.2 13.5 - 16.5 16.2 - 19.8 21.6 - 26.4 protection circuit and others overcurrent protection works over 105% of rating and recovers automatically overvoltage protection 4.00 - 5.25v works at 115 - 140% of rating operating indication led ( green ) remote sensing provided remote on/off not provided isolation input-output ac2 , 000v 1minute , cutoff current = 10ma max , dc500v 50m w min ( at room temperature ) input-fg , cover ac2 , 000v 1minute , cutoff current = 10ma max , dc500v 50m w min ( at room temperature ) output-fg , cover ac500v 1minute , cutoff current = 100ma max , dc500v 50m w min ( at room temperature ) environment operating temp. , humid.and altitude -10 to +60 c , 20 - 90%rh ( non condensing )( refer to derating curve ), 3 , 000m ( 10 , 000feet ) max storage temp. , humid.and altitude -20 to +75 c , 20 - 90%rh ( non condensing ), 9 , 000m ( 30 , 000feet ) max vibration 10 - 55hz , 19.6m/s 2 ( 2g ), 3minutes period , 60minutes each along x , y and z axis impact 196.1m/s 2 ( 20g ), 11ms , once each x , y and z axis safety and noise regulations agency approvals ul60950-1 , csa c22.2 no.60950-1 , en60950-1 complies with den-an and iec60950-1 conducted noise complies with fcc-b , vcci-b others case size/weight 44.5 x 93 x 175mm ( w x h x d ) / 900g max ( without cover ) cooling method convection * 1 drift is the change in dc output for an eight hour period after a half-hour warm-up at 25 c , with the input voltage held constant at the rated input/output. * 2 please contact us about safety approvals for the model with option. * avoid prolonged use under over-load. * parallel operation with other model is not possible. * derating is required when operated with case cover. r150u ac-dc power supplies enclosed type r 150 u -5 - o ordering information 1 series name 2 output wattage 3 ul recognized,t u v approved,csa certified 4 output voltage 5 optional * 2 c :with coating g :low leakage current n :with cover r 12345 r r-12 ? overcurrent characteristics ( r150u-5 ) ? static characteristics ( r150u-5 ) ? rise time & fall time ( r150u-5 ) ? derating curve r r-13 r150u external view ? weight : 900g or less (without cover) ? cover is optional ? tolerance : t 1 ? dimensions in mm. mounting torque: 1.2n ? m(12.8kgf ? cm)max performance data |
Price & Availability of R50A-15-N |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |