Part Number Hot Search : 
TP518 11300 PS11405 060CT LTC1647 DF3A6 ZFVG05A2 2SC4968
Product Description
Full Text Search
 

To Download R50A-15-N Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
  model r10a-3 r10a-5 r10a-12 r10a-15 r10a-24 max output wattage[w] 6 10 10.8 10.5 12 dc output 3v 2.0a 5v 2.0a 12v 0.9a 15v 0.7a 24v 0.5a specifications model r10a-3 r10a-5 r10a-12 r10a-15 r10a-24 input voltage[v] ac85 - 132 1 f or dc110 - 170 current[a] acin 100v 0.24typ ( io=100% ) frequency[hz] 47 - 440 or dc efficiency[%] 64typ 70typ 75typ 76typ 78typ inrush current[a] acin 100v 20typ ( io=100% )( at cold start ) leakage current[ma] 0.5max ( according to ul , csa and den-an ) output voltage[v] 3 5 121524 current[a] 2.0 2.0 0.9 0.7 0.5 line regulation[mv] 20max 20max 48max 60max 96max load regulation[mv] 40max 40max 100max 120max 150max ripple[mvp-p] 0to+50 c 80max 80max 120max 120max 120max -10-0 c 140max 140max 160max 160max 160max ripple noise[mvp-p] 0to+50 c 120max 120max 150max 150max 150max -10-0 c 160max 160max 180max 180max 180max temperature regulation[mv] 0to+50 c 50max 50max 120max 150max 240max -10 to +50 c 60max 60max 150max 180max 290max drift[mv] * 1 20max 20max 48max 60max 96max start-up time[ms] 100max ( acin 85v , io=100% ) hold-up time[ms] 10typ ( acin 85v , io=100% , 0to+50 c ) 20typ ( acin 100v , io=100% , 0to+50 c ) output voltage adjustment range[v] 2.85 - 3.6 4.5 - 5.5 10.8 - 13.2 13.5 - 16.5 21.6 - 26.4 protection circuit and others overcurrent protection works over 105% of rating and recovers automatically ( acin 100v ) overvoltage protection 4.00v min works over 115% of rating ( by zener diode clamping ) operating indication led ( green ) remote sensing not provided remote on/off not provided isolation input-output ac2 , 000v 1minute , cutoff current = 10ma max , dc500v 50m w min ( at room temperature ) input-fg , cover ac2 , 000v 1minute , cutoff current = 10ma max , dc500v 50m w min ( at room temperature ) output-fg , cover ac500v 1minute , cutoff current = 100ma max , dc500v 50m w min ( at room temperature ) environment operating temp. , humid.and altitude -10 to +60 c , 20 - 90%rh ( non condensing )( refer to derating curve ), 3 , 000m ( 10 , 000feet ) max storage temp. , humid.and altitude -20 to +75 c , 20 - 90%rh ( non condensing ), 9 , 000m ( 30 , 000feet ) max vibration 10 - 55hz , 19.6m/s 2 ( 2g ), 3minutes period , 60minutes each along x , y and z axis impact 196.1m/s 2 ( 20g ), 11ms , once each x , y and z axis safety and noise regulations agency approvals ul60950-1 , c-ul complies with den-an conducted noise complies with fcc-b , vcci-b others case size/weight 26 x 68 x 68mm ( w x h x d ) /150g max ( without cover ) cooling method convection * 1 drift is the change in dc output for an eight hour period after a half-hour warm-up at 25 c , with the input voltage held constant at the rated input/output. * 2 please contact us about safety approvals for the model with option. * avoid prolonged use under over-load. * series/parallel operation with other model is not possible. * derating is required when operated with case cover. r10a ac-dc power supplies enclosed type r 10a -5 - o ordering information 1 series name 2 output wattage 3 output voltage 4 optional * 2 g :low leakage current j :connector type n :with cover r 1234 r r-2
? derating curve ? rise time & fall time (r10a-5) ? overcurrent characteristics (r10a-5) ? static characteristics (r10a-5) v m v p-p output voltage ripple io=100% 4.20 4.40 4.60 4.80 5.00 5.20 0 50 60 70 80 90 100 110 120 130 10 20 30 40 v 60hz acin 100v dc output ac input io=100% 20ms/div please see electric characteristics for shaded ripple, ripple noise. 1 convection 2 1 2 forced air (0.5m 3 /min) v v a 1.0 2.0 3.0 4.0 5.0 6.0 0 1.0 2.0 0 20 40 60 80 100 -10 0 10 20 30 40[30] 50[40] 60[50] 70[60] a output voltage ripple input voltage output voltage output current output voltage ambient temperature inside of means with cover r r-3 r10a external view (mfr : j.s.t.) (mfr : j.s.t.) i/o connector mating connector b3p5 - vh b4p - vh vhr - 5n ? weight : 150g or less (without cover) ? cover is optional ? tolerance : t 1 ? dimensions in mm. connector type barrier strip type terminal + fg cn2 cn1 ac(l) ac(n) - + fg ac( l ) ac(n) - chain: svh-21-p1.1 loose: bvh-21-p1.1 vhr - 4n max (10) m3 cover (13) safety cover 22 (21) voltage adjust led name plate name plate 2 - m3 mounting hole name plate (61) (13.5) 7.5 37 14 22.5 26 3.5 63.5 o 3.5 68 9.5 50 t 0.5 2 - m3 mounting hole 14 68 max 26 t 0.2 36 cn1 cn2 mounting torque: 0.6n ? m(6.3kgf ? cm)max performance data
model r15a-3 r15a-5 r15a-9 r15a-12 r15a-15 r15a-18 r15a-24 max output wattage[w] 9 15 15.3 15.6 15 15.3 16.8 dc output 3v 3.0a 5v 3a 9v 1.7a 12v 1.3a 15v 1.0a 18v 0.85a 24v 0.7a specifications model r15a-3 r15a-5 r15a-9 r15a-12 r15a-15 r15a-18 r15a-24 input voltage[v] ac85 - 132 1 f or dc110 - 170 current[a] acin 100v 0.37typ ( io=100% ) frequency[hz] 47 - 440 or dc efficiency[%] 68typ 72typ 73typ 75typ 75typ 76typ 78typ inrush current[a] acin 100v 20typ ( io=100% )( at cold start ) leakage current[ma] 0.5max ( according to ul , csa and den-an ) output voltage[v] 35912151824 current[a] 3.0 3.0 1.7 1.3 1.0 0.85 0.7 line regulation[mv] 20max 20max 36max 48max 60max 72max 96max load regulation[mv] 40max 40max 100max 100max 120max 120max 150max ripple[mvp-p] 0to+50 c 80max 80max 120max 120max 120max 120max 120max -10-0 c 140max 140max 160max 160max 160max 160max 160max ripple noise[mvp-p] 0to+50 c 120max 120max 150max 150max 150max 150max 150max -10-0 c 160max 160max 180max 180max 180max 180max 180max temperature regulation[mv] 0to+50 c 50max 50max 90max 120max 150max 180max 240max -10 to +50 c 60max 60max 120max 150max 180max 200max 290max drift[mv] * 1 20max 20max 36max 48max 60max 72max 96max start-up time[ms] 100max ( acin 85v , io=100% ) hold-up time[ms] 10typ ( acin 85v , io=100% , 0to+50 c ) 20typ ( acin 100v , io=100% , 0to+50 c ) output voltage adjustment range[v] 2.85 - 3.6 4.5 - 5.5 8.1 - 9.9 10.8 - 13.2 13.5 - 16.5 16.2 - 19.8 21.6 - 26.4 protection circuit and others overcurrent protection works over 105% of rating and recovers automatically ( acin 100v ) overvoltage protection 4.00v min works over 115% of rating ( by zener diode clamping ) operating indication led ( green ) remote sensing not provided remote on/off not provided isolation input-output ac2 , 000v 1minute , cutoff current = 10ma max , dc500v 50m w min ( at room temperature ) input-fg , cover ac2 , 000v 1minute , cutoff current = 10ma max , dc500v 50m w min ( at room temperature ) output-fg , cover ac500v 1minute , cutoff current = 100ma max , dc500v 50m w min ( at room temperature ) environment operating temp. , humid.and altitude -10 to +60 c , 20 - 90%rh ( non condensing )( refer to derating curve ), 3 , 000m ( 10 , 000feet ) max storage temp. , humid.and altitude -20 to +75 c , 20 - 90%rh ( non condensing ), 9 , 000m ( 30 , 000feet ) max vibration 10 - 55hz , 19.6m/s 2 ( 2g ), 3minutes period , 60minutes each along x , y and z axis impact 196.1m/s 2 ( 20g ), 11ms , once each x , y and z axis safety and noise regulations agency approvals ul60950-1 , c-ul complies with den-an conducted noise complies with fcc-b , vcci-b others case size/weight 30 x 69 x 84mm ( w x h x d ) / 200g max ( without cover ) cooling method convection * 1 drift is the change in dc output for an eight hour period after a half-hour warm-up at 25 c , with the input voltage held constant at the rated input/output. * 2 please contact us about safety approvals for the model with option. * avoid prolonged use under over-load. * series/parallel operation with other model is not possible. * derating is required when operated with case cover. r15a ac-dc power supplies enclosed type r 15a -5 - o ordering information 1 series name 2 output wattage 3 output voltage 4 optional * 2 c :with coating g :low leakage current j :connector type n :with cover r 1234 r r-4
? rise time & fall time (r15a-5) ? static characteristics (r15a-5) ? inrush current (r15a-5) ? overcurrent characteristics (r15a-5) v m v p-p output voltage ripple io=100% 4.20 4.40 4.60 4.80 5.00 5.20 0 50 60 70 80 90 100 110 120 130 10 20 30 40 v 60hz output voltage ripple input voltage acin 100v dc output ac input io=100% 20ms/div v a 1.0 2.0 3.0 4.0 5.0 6.0 0 1.0 2.0 3.0 4.0 output voltage output current 10ms/div frequency 60hz load 100% input voltage ac100v 10a/div r r-5 r15a external view (mfr : j.s.t.) i/o connector mating housing b3p5 - vh b4p - vh vhr - 5n ? weight : 200g or less (without cover) ? cover is optional ? tolerance : t 1 ? dimensions in mm. connector type barrier strip type + fg cn2 cn1 ac(l) ac(n) - + fg ac(l) ac(n) - (10) 22 cover m3 name plate voltage adjust 2 - m3 mounting hole 2 - m3 mounting hole name plate 55 t 0.5 3.5 76 84 14 3 5 3.5 18.5 5 1.75 36.5 69 name plate led max safety cover (23.5) (13.5) (63) (61) (13.5) 7.5 9.5 16 25 30 34 74 t 0.5 max vhr - 4n cn1 cn2 (mfr : j.s.t.) terminal chain: svh-21-p1.1 loose: bvh-21-p1.1 mounting torque: 0.6n ? m(6.3kgf ? cm)max performance data
model r25a-3 r25a-5 r25a-9 r25a-12 r25a-15 r25a-18 r25a-24 max output wattage[w] 15 25 25.2 25.2 25.5 25.2 26.4 dc output 3v 5.0a 5v 5a 9v 2.8a 12v 2.1a 15v 1.7a 18v 1.4a 24v 1.1a specifications model r25a-3 r25a-5 r25a-9 r25a-12 r25a-15 r25a-18 r25a-24 input voltage[v] ac85 - 132 1 f or dc110 - 170 current[a] acin 100v 0.58typ ( io=100% ) frequency[hz] 47 - 440 or dc efficiency[%] 69typ 73typ 75typ 76typ 76typ 77typ 79typ inrush current[a] acin 100v 20typ ( io=100% )( at cold start ) leakage current[ma] 0.5max ( according to ul , csa and den-an ) output voltage[v] 35912151824 current[a] 5.0 5.0 2.8 2.1 1.7 1.4 1.1 line regulation[mv] 20max 20max 36max 48max 60max 72max 96max load regulation[mv] 40max 40max 100max 100max 120max 120max 150max ripple[mvp-p] 0to+50 c 80max 80max 120max 120max 120max 120max 120max -10-0 c 140max 140max 160max 160max 160max 160max 160max ripple noise[mvp-p] 0to+50 c 120max 120max 150max 150max 150max 150max 150max -10-0 c 160max 160max 180max 180max 180max 180max 180max temperature regulation[mv] 0to+50 c 50max 50max 90max 120max 150max 180max 240max -10 to +50 c 60max 60max 120max 150max 180max 200max 290max drift[mv] * 1 20max 20max 36max 48max 60max 72max 96max start-up time[ms] 200max ( acin 85v , io=100% ) hold-up time[ms] 10typ ( acin 85v , io=100% , 0to+50 c ) 20typ ( acin 100v , io=100% , 0to+50 c ) output voltage adjustment range[v] 2.85 - 3.6 4.5 - 5.5 8.1 - 9.9 10.8 - 13.2 13.5 - 16.5 16.2 - 19.8 21.6 - 26.4 protection circuit and others overcurrent protection works over 105% of rating and recovers automatically ( acin 100v ) overvoltage protection 4.00 - 5.25v works at 115 - 140% of rating operating indication led ( green ) remote sensing not provided remote on/off not provided isolation input-output ac2 , 000v 1minute , cutoff current = 10ma max , dc500v 50m w min ( at room temperature ) input-fg , cover ac2 , 000v 1minute , cutoff current = 10ma max , dc500v 50m w min ( at room temperature ) output-fg , cover ac500v 1minute , cutoff current = 100ma max , dc500v 50m w min ( at room temperature ) environment operating temp. , humid.and altitude -10 to +60 c , 20 - 90%rh ( non condensing )( refer to derating curve ), 3 , 000m ( 10 , 000feet ) max storage temp. , humid.and altitude -20 to +75 c , 20 - 90%rh ( non condensing ), 9 , 000m ( 30 , 000feet ) max vibration 10 - 55hz , 19.6m/s 2 ( 2g ), 3minutes period , 60minutes each along x , y and z axis impact 196.1m/s 2 ( 20g ), 11ms , once each x , y and z axis safety and noise regulations agency approvals ul60950-1 , c-ul complies with den-an conducted noise complies with fcc-b , vcci-b others case size/weight 31 x 69 x 104mm ( w x h x d ) / 250g max ( without cover ) cooling method convection * 1 drift is the change in dc output for an eight hour period after a half-hour warm-up at 25 c , with the input voltage held constant at the rated input/output. * 2 please contact us about safety approvals for the model with option. * avoid prolonged use under over-load. * series/parallel operation with other model is not possible. * derating is required when operated with case cover. r25a ac-dc power supplies enclosed type r 25a -5 - o ordering information 1 series name 2 output wattage 3 output voltage 4 optional * 2 c :with coating g :low leakage current j :connector type n :with cover r 1234 r r-6
? inrush current (r25a-5) ? rise time & fall time (r25a-5) ? static characteristics (r25a-5) ? overcurrent characteristics (r25a-5) v m v p-p output voltage ripple io=100% 4.20 4.40 4.60 4.80 5.00 5.20 0 50 60 70 80 90 100 110 120 130 10 20 30 40 v 60hz output voltage input voltage ripple acin 100v dc output ac input io=100% 20ms/div v 1.0 2.0 3.0 4.0 5.0 6.0 0 2.0 4.0 6.0 8.0 a output voltage output current 10ms/div 10a/div frequency 60hz load 100% input voltage ac100v r r-7 r25a external view (mfr : j.s.t.) i/o connector mating housing b3p5 - vh b4p - vh vhr - 5n connector type vhr - 4n cn1 cn2 (mfr : j.s.t.) terminal chain: svh-21-p1.1 loose: bvh-21-p1.1 + fg cn2 cn1 ac(l) ac(n) - ? weight : 250g or less (without cover) ? cover is optional ? tolerance : t 1 ? dimensions in mm. barrier strip type + fg ac(l) ac(n) - (10) 22 cover m3 name plate voltage adjust 2 - m3 mounting hole 70 t 0.5 23.5 36.5 69 name plate led max safety cover (23.5) (13.5) (63) (61) (13.5) 7.5 9.5 3 - m3 mounting hole name plate o 3.5 96 104 14 3 3.5 17.5 26 31 35 90 t 0.5 9 83 t 0.5 max mounting torque: 0.6n ? m(6.3kgf ? cm)max performance data
model r50a-3 r50a-5 r50a-9 r50a-12 r50a-15 r50a-18 r50a-24 max output wattage[w] 30 50 50.4 50.4 51 50.4 52.8 dc output 3v 10a 5v 10a 9v 5.6a 12v 4.2a 15v 3.4a 18v 2.8a 24v 2.2a specifications model r50a-3 r50a-5 r50a-9 r50a-12 r50a-15 r50a-18 r50a-24 input voltage[v] ac85 - 132 1 f or dc110 - 170 current[a] acin 100v 1.1typ ( io=100% ) frequency[hz] 47 - 440 or dc efficiency[%] 74typ 78typ 79typ 80typ 81typ 82typ 83typ inrush current[a] acin 100v 30typ ( io=100% )( at cold start ) leakage current[ma] 0.5max ( according to ul , csa and den-an ) output voltage[v] 35912151824 current[a] 10 10 5.6 4.2 3.4 2.8 2.2 line regulation[mv] 20max 20max 36max 48max 60max 72max 96max load regulation[mv] 40max 40max 100max 100max 120max 120max 150max ripple[mvp-p] 0to+50 c 80max 80max 120max 120max 120max 120max 120max -10-0 c 140max 140max 160max 160max 160max 160max 160max ripple noise[mvp-p] 0to+50 c 120max 120max 150max 150max 150max 150max 150max -10-0 c 160max 160max 180max 180max 180max 180max 180max temperature regulation[mv] 0to+50 c 50max 50max 90max 120max 150max 180max 240max -10 to +50 c 60max 60max 120max 150max 180max 200max 290max drift[mv] * 1 20max 20max 36max 48max 60max 72max 96max start-up time[ms] 200max ( acin 85v , io=100% ) hold-up time[ms] 10typ ( acin 85v , io=100% , 0to+50 c ) 20typ ( acin 100v , io=100% , 0to+50 c ) output voltage adjustment range[v] 2.85 - 3.6 4.5 - 5.5 8.1 - 9.9 10.8 - 13.2 13.5 - 16.5 16.2 - 19.8 21.6 - 26.4 protection circuit and others overcurrent protection works over 105% of rating and recovers automatically ( acin 100v ) overvoltage protection 4.00 - 5.25v works at 115 - 140% of rating operating indication led ( green ) remote sensing not provided remote on/off not provided isolation input-output ac2 , 000v 1minute , cutoff current = 10ma max , dc500v 50m w min ( at room temperature ) input-fg , cover ac2 , 000v 1minute , cutoff current = 10ma max , dc500v 50m w min ( at room temperature ) output-fg , cover ac500v 1minute , cutoff current = 100ma max , dc500v 50m w min ( at room temperature ) environment operating temp. , humid.and altitude -10 to +60 c , 20 - 90%rh ( non condensing )( refer to derating curve ), 3 , 000m ( 10 , 000feet ) max storage temp. , humid.and altitude -20 to +75 c , 20 - 90%rh ( non condensing ), 9 , 000m ( 30 , 000feet ) max vibration 10 - 55hz , 19.6m/s 2 ( 2g ), 3minutes period , 60minutes each along x , y and z axis impact 196.1m/s 2 ( 20g ), 11ms , once each x , y and z axis safety and noise regulations agency approvals ul60950-1 , c-ul complies with den-an conducted noise complies with fcc-b , vcci-b others case size/weight 33 x 85 x 119mm ( w x h x d ) / 300g max ( without cover ) cooling method convection * 1 drift is the change in dc output for an eight hour period after a half-hour warm-up at 25 c , with the input voltage held constant at the rated input/output. * 2 please contact us about safety approvals for the model with option. * avoid prolonged use under over-load. * parallel operation is not possible. * derating is required when operated with case cover. r50a ac-dc power supplies enclosed type r 50a -5 - o ordering information 1 series name 2 output wattage 3 output voltage 4 optional * 2 c :with coating g :low leakage current j :connector type n :with cover r 1234 r r-8
? inrush current (r50a-5) ? rise time & fall time (r50a-5) ? static characteristics (r50a-5) ? overcurrent characteristics (r50a-5) v m v p-p output voltage ripple io=100% 4.20 4.40 4.60 4.80 5.00 5.20 5.40 0 50 60 70 80 90 100 110 120 130 30 40 50 60 70 80 20 v 60hz output voltage ripple input voltage acin 100v dc output ac input io=100% 20ms/div v a 1.0 2.0 3.0 4.0 5.0 6.0 0 510 15 output voltage output current 10ms/div 10a/div frequency 60hz load 100% input voltage ac100v r r-9 r50a external view (mfr : j.s.t.) i/o connector mating housing b3p5 - vh b4p - vh vhr - 5n connector type vhr - 4n cn1 cn2 (mfr : j.s.t.) terminal chain: svh-21-p1.1 loose: bvh-21-p1.1 ? weight : 300g or less (without cover) ? cover is optional ? tolerance : t 1 ? dimensions in mm. barrier strip type + fg cn1 ac(l) ac(n) - cn2 + fg ac(l) ac(n) - 17.5 cover m3 name plate voltage adjust 2 - m3 mounting hole 35 name plate led max safety cover (14) (72) (61) (13.5) 7.5 9.5 (10.5) (24) 70 t 0.5 23 85 2 - m3 max mounting hole name plate o 3.5 3 3.5 17.5 30 33 37 14 119 100 t 0.5 111 14 mounting torque: 0.49n?m(5.0kgf?cm)max performance data
model r100u-3 r100u-5 r100u-9 r100u-12 r100u-15 r100u-18 r100u-24 max output wattage[w] 60 100 103.5 102 105 100.8 108 dc output 3v 20a 5v 20a 9v 11.5a 12v 8.5a 15v 7a 18v 5.6a 24v 4.5a specifications model r100u-3 r100u-5 r100u-9 r100u-12 r100u-15 r100u-18 r100u-24 input voltage[v] ac85 - 132 1 f or dc110 - 170 current[a] acin 100v 2.8typ ( io=100% ) frequency[hz] 47 - 440 or dc efficiency[%] 75typ 79typ 80typ 82typ 83typ 84typ 85typ inrush current[a] acin 100v 15typ ( io=100% ) leakage current[ma] 0.5max ( 60hz , according to ul , csa and den-an ) output voltage[v] 3 5 9 12151824 current[a] 20 20 11.5 8.5 7 5.6 4.5 line regulation[mv] 20max 20max 36max 48max 60max 72max 96max load regulation[mv] 40max 40max 100max 100max 120max 120max 150max ripple[mvp-p] 0to+50 c 80max 80max 120max 120max 120max 120max 120max -10-0 c 140max 140max 160max 160max 160max 160max 160max ripple noise[mvp-p] 0to+50 c 120max 120max 150max 150max 150max 150max 150max -10-0 c 160max 160max 180max 180max 180max 180max 180max temperature regulation[mv] 0to+50 c 50max 50max 90max 120max 150max 180max 240max -10 to +50 c 60max 60max 120max 150max 180max 200max 290max drift[mv] * 1 20max 20max 36max 48max 60max 72max 96max start-up time[ms] 200max ( acin 85v , io=100% ) hold-up time[ms] 20typ ( acin 100v , io=100% , 0to+50 c ) 10typ ( acin 85v , io=100% , 0to+50 c ) output voltage adjustment range[v] 2.85 - 3.6 4.5 - 5.5 8.1 - 9.9 10.8 - 13.2 13.5 - 16.5 16.2 - 19.8 21.6 - 26.4 protection circuit and others overcurrent protection works over 105% of rating and recovers automatically overvoltage protection 4.00 - 5.25v works at 115 - 140% of rating operating indication led ( green ) remote sensing provided remote on/off not provided isolation input-output ac2 , 000v 1minute , cutoff current = 10ma max , dc500v 50m w min ( at room temperature ) input-fg , cover ac2 , 000v 1minute , cutoff current = 10ma max , dc500v 50m w min ( at room temperature ) output-fg , cover ac500v 1minute , cutoff current = 100ma max , dc500v 50m w min ( at room temperature ) environment operating temp. , humid.and altitude -10 to +60 c , 20 - 90%rh ( non condensing )( refer to derating curve ), 3 , 000m ( 10 , 000feet ) max storage temp. , humid.and altitude -20 to +75 c , 20 - 90%rh ( non condensing ), 9 , 000m ( 30 , 000feet ) max vibration 10 - 55hz , 19.6m/s 2 ( 2g ), 3minutes period , 60minutes each along x , y and z axis impact 196.1m/s 2 ( 20g ), 11ms , once each x , y and z axis safety and noise regulations agency approvals ul60950-1 , csa c22.2 no.60950-1 , en60950-1 complies with den-an and iec60950-1 conducted noise complies with fcc-b , vcci-b others case size/weight 34.5 x 93 x 160mm ( w x h x d ) / 600gmax ( without cover ) cooling method convection * 1 drift is the change in dc output for an eight hour period after a half-hour warm-up at 25 c , with the input voltage held constant at the rated input/output. * 2 please contact us about safety approvals for the model with option. * avoid prolonged use under over-load. * parallel operation with other model is not possible. * derating is required when operated with case cover. r100u ac-dc power supplies enclosed type r 100 u -5 - o ordering information 1 series name 2 output wattage 3 ul recognized,t u v approved,csa certified 4 output voltage 5 optional * 2 c :with coating g :low leakage current n :with cover r 12345 r r-10
? overcurrent characteristics ( r100u-5 ) ? static characteristics ( r100u-5 ) ? rise time & fall time ( r100u-5 ) ? derating curve r r-11 r100u external view ? weight : 600g or less (without cover) ? cover is optional ? tolerance : t 1 ? dimensions in mm. mounting torque: 1.2n ? m(12.8kgf ? cm)max performance data
model r150u-3 r150u-5 r150u-9 r150u-12 r150u-15 r150u-18 r150u-24 max output wattage[w] 90 150 153 156 150 153 156 dc output 3v 30a 5v 30a 9v 17a 12v 13a 15v 10a 18v 8.5a 24v 6.5a specifications model r150u-3 r150u-5 r150u-9 r150u-12 r150u-15 r150u-18 r150u-24 input voltage[v] ac85 - 132 1 f or dc110 - 170 current[a] acin 100v 4.2typ ( io=100% ) frequency[hz] 47 - 440 or dc efficiency[%] 74typ 78typ 79typ 80typ 82typ 83typ 84typ inrush current[a] acin 100v 15typ ( io=100% ) leakage current[ma] 0.5max ( 60hz , according to ul , csa and den-an ) output voltage[v] 3 5 9 12151824 current[a] 30 30 17 13 10 8.5 6.5 line regulation[mv] 20max 20max 36max 48max 60max 72max 96max load regulation[mv] 40max 40max 100max 100max 120max 120max 150max ripple[mvp-p] 0to+50 c 80max 80max 120max 120max 120max 120max 120max -10-0 c 140max 140max 160max 160max 160max 160max 160max ripple noise[mvp-p] 0to+50 c 120max 120max 150max 150max 150max 150max 150max -10-0 c 160max 160max 180max 180max 180max 180max 180max temperature regulation[mv] 0to+50 c 50max 50max 90max 120max 150max 180max 240max -10 to +50 c 60max 60max 120max 150max 180max 200max 290max drift[mv] * 1 20max 20max 36max 48max 60max 72max 96max start-up time[ms] 200max ( acin 85v , io=100% ) hold-up time[ms] 20typ ( acin 100v , io=100% , 0to+50 c ) 10typ ( acin 85v , io=100% , 0to+50 c ) output voltage adjustment range[v] 2.85 - 3.6 4.5 - 5.5 8.1 - 9.9 10.8 - 13.2 13.5 - 16.5 16.2 - 19.8 21.6 - 26.4 protection circuit and others overcurrent protection works over 105% of rating and recovers automatically overvoltage protection 4.00 - 5.25v works at 115 - 140% of rating operating indication led ( green ) remote sensing provided remote on/off not provided isolation input-output ac2 , 000v 1minute , cutoff current = 10ma max , dc500v 50m w min ( at room temperature ) input-fg , cover ac2 , 000v 1minute , cutoff current = 10ma max , dc500v 50m w min ( at room temperature ) output-fg , cover ac500v 1minute , cutoff current = 100ma max , dc500v 50m w min ( at room temperature ) environment operating temp. , humid.and altitude -10 to +60 c , 20 - 90%rh ( non condensing )( refer to derating curve ), 3 , 000m ( 10 , 000feet ) max storage temp. , humid.and altitude -20 to +75 c , 20 - 90%rh ( non condensing ), 9 , 000m ( 30 , 000feet ) max vibration 10 - 55hz , 19.6m/s 2 ( 2g ), 3minutes period , 60minutes each along x , y and z axis impact 196.1m/s 2 ( 20g ), 11ms , once each x , y and z axis safety and noise regulations agency approvals ul60950-1 , csa c22.2 no.60950-1 , en60950-1 complies with den-an and iec60950-1 conducted noise complies with fcc-b , vcci-b others case size/weight 44.5 x 93 x 175mm ( w x h x d ) / 900g max ( without cover ) cooling method convection * 1 drift is the change in dc output for an eight hour period after a half-hour warm-up at 25 c , with the input voltage held constant at the rated input/output. * 2 please contact us about safety approvals for the model with option. * avoid prolonged use under over-load. * parallel operation with other model is not possible. * derating is required when operated with case cover. r150u ac-dc power supplies enclosed type r 150 u -5 - o ordering information 1 series name 2 output wattage 3 ul recognized,t u v approved,csa certified 4 output voltage 5 optional * 2 c :with coating g :low leakage current n :with cover r 12345 r r-12
? overcurrent characteristics ( r150u-5 ) ? static characteristics ( r150u-5 ) ? rise time & fall time ( r150u-5 ) ? derating curve r r-13 r150u external view ? weight : 900g or less (without cover) ? cover is optional ? tolerance : t 1 ? dimensions in mm. mounting torque: 1.2n ? m(12.8kgf ? cm)max performance data


▲Up To Search▲   

 
Price & Availability of R50A-15-N

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X