  F-51430NFU-FW-AA ( aa ) no. 2001-0115 optrex corporation page 1 / 20 lcd module technical specification F-51430NFU-FW-AA table of contents 1. general specifications ................................ ................................ ................................ .................... 2 2. electrical specifications ................................ ................................ ................................ .................. 3 3. optical specifications ................................ ................................ ................................ ....................... 9 4. i/o terminal ................................ ................................ ................................ ................................ ........ 11 5. test ................................ ................................ ................................ ................................ ......................... 14 6. appearance standards ................................ ................................ ................................ ................. 15 7. code system of production lot ................................ ................................ ................................ 18 8. type number ................................ ................................ ................................ ................................ ...... 18 9 . applying precautions ................................ ................................ ................................ ...................... 18 10 . precautions relating product handling ................................ ................................ ............... 19 1 1 . warranty ................................ ................................ ................................ ................................ ............. 20 checked by ( design engineering div. ) checked by ( quality assurance div. ) approved by ( production div. ) prepared by ( production div. ) revision history rev. date page comment type no. jun 2 1 , 2001 optrex first edition final revision ******
F-51430NFU-FW-AA ( aa ) no. 2001-0115 optrex corporation page 2 / 20 1. general specifications operating temp. : min. 0 c ~max. 50 c storage temp. : min. -20 c ~max. 60 c dot pixels : 640 (w) ?~ 480 (h) dots dot size : 0.27 (w) ?~ 0.27 (h) mm dot pitch : 0.30 (w) ?~ 0.30 (h) mm viewing area : 196.0 (w) ?~ 148.0 (h) mm outline dimensions : 260 .0 * (w) ?~ 174.0 (h) ?~ 8.5 max. (d) mm * without cfl cable weight : 410g max. lcd type : ntd-21140 ( f-stn / black &white-mode / transmissive ) viewing angle : 12:00 data transfer : 4-bit parallel data transfer ?~ 2 backlight : cold cathode fluorescent lamp (cfl) ?~ 1 drawings : dimensional outline ue-210259-00
F-51430NFU-FW-AA ( aa ) no. 2001-0115 optrex corporation page 3 / 20 2. electrical specifications 2.1. absolute maximum ratings v ss =0v parameter symbol conditions min. max. units supply voltage (logic) v cc -v ss - -0.3 7.0 v supply voltage (lcd drive) v hh -v ss - -0.3 30.0 v input voltage v i - -0.3 v cc +0.3 v 2.2. dc characteristics ta=25 c , v ss =0v parameter symbol conditions min. typ. max. units supply voltage (logic) v cc -v ss - 2.5 - 5.5 v supply voltage (lcd drive) v hh -v ss shown in 3.1 v high level input voltage v ih v cc =2.5~5.5v 0.8 v cc - v cc v low level input voltage v il v cc =2.5~5.5v 0 - 0.2 v cc v supply current i cc v cc -v ss =5.0v - 14.0 25.0 ma i hh v hh -v ss =21.6v - 9.0 20.0 ma
F-51430NFU-FW-AA ( aa ) no. 2001-0115 optrex corporation page 4 / 20 2.3. ac characteristics v cc = 2.5 ~ 4 .5v parameter symbol min. max. units shift clock p eriod t wck 125 - ns shift clock ? h ? pulse width t wckh 51 - ns shift clock ? l ? pulse width t wckl 51 - ns data setup time t ds 30 - ns data hold time t dh 40 - ns latch pulse ? h ? pulse width t wlph 51 - ns shift clock rise to latch pulse rise t ld 0 - ns shift clock fall to latch pulse fall t sl 51 - ns latch pulse rise to shift clock rise t ls 51 - ns latch pulse fall to shift clock rise t lh 51 - ns input signal rise ,fall time t r, t f - 50 note.1 ns data setup time t su 30 - ns data hold time t h 50 - ns dispoff removal time t s d 100 - ns dispoff enable pulse width t wdl 1.2 - m s v cc = 4 . 5 ~5.5v parameter symbol min. max. units shift clock p eriod t wck 71 - ns shift clock ? h ? pulse width t wckh 23 - ns shift clock ? l ? pulse width t wckl 23 - ns data setup time t ds 10 - ns data hold time t dh 20 - ns latch pulse ? h ? pulse width t wlph 23 - ns shift clock rise to latch pulse rise t ld 0 - ns shift clock fall to latch pulse fall t sl 25 - ns latch pulse rise to shift clock rise t ls 25 - ns latch pulse fall to shift clock rise t lh 25 - ns input signal rise ,fall time t r, t f - 50 note.1 ns data setup time t su 30 - ns data hold time t h 50 - ns dispoff reoval time t s d 100 - ns dispoff enable pulse width t wdl 1.2 - m s note.1 : ( t ck ? twckll - twckl)/2 is the maximum in case of high speed operation.
F-51430NFU-FW-AA ( aa ) no. 2001-0115 optrex corporation page 5 / 20 t wdl t sd t r t f t dh t ds t wckl t lh t sl cp t ld t ls lp dispoff du 0~ du3 dl 0~ dl3 t wlph top data last data t wck t wckh flm t su t h
F-51430NFU-FW-AA ( aa ) no. 2001-0115 optrex corporation page 6 / 20 2.4. timing chart 2.5. comparison of display and data t=0.0595ms typ. 240xt flm (reduction) (reduction) lp flm m du3 du0 cp lp #1 data seg seg seg seg seg seg seg seg 640 636 8 4 640 636 8 4 637~ 633~ 5~ 1~ 637~ 633~ 5~ 1~ dl3 dl0 #241 data seg seg seg seg seg seg seg seg 1280 1276 648 644 1280 1276 648 644 1277~ 1273~ 645~ 641~ 1277~ 1273~ 645~ 641~ seg1 seg640 #241 #1 #240 #480 du2 du3 du0~du3 dl0~dl3 seg641 seg1280 du0 du1 du0 du1 dl2 dl3 dl0 dl1 dl0 dl1 upper data lower data
F-51430NFU-FW-AA ( aa ) no. 2001-0115 optrex corporation page 7 / 20 2.6. power supply on/off sequence 2.6.1. on sequence 2.6.2. off sequence please maintain the above sequence when turning on and off the power supply of the module. if dispoff is supplied to the module w hile internal alternate signal for lcd driving (m) is unstable , dc component will be supplied to the lcd panel. this may cause damage the lcd module. vss vcc vss vss vcc vss vcc dispoff vhh vcc 0 t 0 t signal signal level vhh 0 t vss vcc vss vss vcc vss vcc dispoff vhh vcc 0 t 0 t signal signal level vhh 0 t
F-51430NFU-FW-AA ( aa ) no. 2001-0115 optrex corporation page 8 / 20 2.7. lighting specifications ta=25 c parameter symbol conditions min. typ. max. units note lamp voltage v l - - 340 - vrms 1 lamp current i l - 5.5 6.0 6.5 marms 2 starting voltage v s - 855 - - vrms 3 surface l i l =6.0ma 90 110 - cd/m 2 4 average life t al i l =6.0ma - 10000 - hrs 5 note 1 :the voltage ( r.m.s. ) to maintain the electric discharge of the lamp. it is measured after lighting for 3 minutes . note 2 :the current ( r.m.s. ) to flow through the lamp with the electric discharge. it is measured after lighting for 3 minutes. note 3 :the voltage at starting the electric discharge when the voltage is increased gradually from 0v. note 4 :surface luminance is specified by the average of 9 luminance values measured at each point shown above after 20 minutes power on with the all on pattern adjusted to maximum contrast and the dimming control of 100%. ( maximum brightness ) note 5 : cfl life is defined as time period that the actual luminance becomes 50% or lower of its initial value. the average life time of cfl is defined as the time when half or more of the testing cfls have become less bright than 50% of the initial brightness at continuous operation. recommended inverter : s-12565 ( produced by elevam ) cxa-m10a (dc 5.0v, produced by tdk) cxa-m10l (dc 12.0v, produced by tdk) v n i cfl testing circuit l f c vs vl il measurement points p7 p4 p1 x=240 x=60 x=420 y=580 y=320 y=60 p8 p5 p2 p9 p6 p3
F-51430NFU-FW-AA ( aa ) no. 2001-0115 optrex corporation page 9 / 20 3. optical specifications 3.1. lcd driving voltage parameter symbol conditions min. typ. max. units recommended ta= 0 c - - 25.0 v lcd driving voltage v hh -v ss ta=25 c 20.1 21.6 23.1 v note 1 ta=50 c 18.4 - - v note 1 : voltage (applied actual waveform to lcd module) for the best contrast. the range of minimum and maximum shows tolerance of the operating voltage. the specified contrast ratio and response time are not guaranteed over the entire range. 3.2. optical characteristics ta=25 c , 1/240 duty, 1/12 bias, v od =21.6v (note 4) , q = 0 c , f =- parameter symbol conditions min. typ. max. units contrast ratio note cr q = 0 c , f =- - 14 - viewing angle shown in 3.3 respons rise note 2 t on - - 210 320 ms time decay note t off - - 120 180 ms note 1 :contrast ratio is definded as follows. cr = l on / l off l on : luminance of t he on segments l off : luminance of the off segments note 2 :the time that the luminance level reaches 90% of the saturation level from 0% when on signal is applied. note 3 :the time that the luminance level reaches 10% of the saturation level from 100% when off signal is applied. note 4 :definition of driving voltage v od v od =v cc -v adj -v be assuming that the typical driving waveforms shown below are applied to the lcd panel at 1/a duty - 1/b bias ( a: duty number, b: bias number). driving voltage v od is definded as the voltage v o-p when the contrast ratio (cr=l on / l off ) is at its maximum. vo-p 1 / f f ( b-2 ) vo-p/b 1/ ( f f a ) ( off signal ) ( on signal )
F-51430NFU-FW-AA ( aa ) no. 2001-0115 optrex corporation page 10 / 20 3.3. definition of viewing angle and optimum viewing area *point shows the point where contrast ratio is measured. : q = 0 , f = - *driving condition: 1/240 duty, 1/12 bias, v od =21.6v, f f =70.0hz 270 0 90 180 270 q f 135 315 225 45 180 90 ( f = 0 ) f 10 20 30 40 50 q *area shows typ. cr 3 2 3.4. system block diagram halogen bulb computer rotation table ( q , f ) temperature chamber lcd optical fiber waveform generator control unit & #1980a wb photometer f q
F-51430NFU-FW-AA ( aa ) no. 2001-0115 optrex corporation page 11 / 20 4. i/o terminal 4.1. pin assignment cn1 no. symbol level function 1 flm h / l first line marker 2 lp h / l data latch signal 3 cp h / l clock signal for shifting data 4 dispoff h / l display control signal h : display on l : display off 5 v cc - power supply for logic 6 v ss - power supply (0v, gnd) 7 v hh - power supply for lcd drive (+ voltage) 8 du0 h / l display upper data 9 du1 h / l display upper data 10 du2 h / l display upper data 11 du3 h / l display upper data 12 dl0 h / l display lower data 13 dl1 h / l display lower data 14 dl2 h / l display lower data 15 dl3 h / l display lower data cn2 no. symbol level function 5 cfl out1(hot) - power supply for cfl (hot) 6 nc - non-connection 7 nc - non-connection 8 cfl - power supply for cfl (gnd) 4.2. example of power supply it is recommended to apply a potentiometer for the contrast adjust due to the tolerance of the driving voltage and its temperature dependence. module vcc vhh vss vcc (logic) vhh (+voltage) r1+r2+vr=10~ 20 k w vss (0v) r2 r1 vr tr
F-51430NFU-FW-AA ( aa ) no. 2001-0115 optrex corporation page 12 / 20
F-51430NFU-FW-AA ( aa ) no. 2001-0115 optrex corporation page 13 / 20 4.3. block diagram cfl out2(gnd) cfl out1(hot) vhh vss vcc du0~du3 flm lp dispoff cp or equivalent nt7701 3 m cir . m row driver or equivalent nt7701 4 column driver l c d p 640 240 4 640 480 dots to lsi logic cfl backlight or equivalent nt7701 4 column driver 640 240 4 bias circuit to lsi dl0~dl3
F-51430NFU-FW-AA ( aa ) no. 2001-0115 optrex corporation page 14 / 20 5. test no change on display and in operation under the following test condition. conditions : unless otherwise specified, tests will be conducted under the following condition. temperature: 20 5 c humidity : 65 5% rh tests will be not conducted under functioning state. no. parameter conditions notes 1 high temperature 50 c 2 c, 96hrs (operation state) 2 low temperature 0 c 2 c, 96hrs (operation state) 1 3 high temperature storage 60 c 2 c, 96hrs 2 4 low temperature storage -20 c 2 c, 96hrs 1,2 5 damp proof test 40 c 2 c,90~95%rh, 96hrs 1,2 6 vibration test total fixed amplitude : 1.5mm 3 vibration frequency : 10~55hz one cycle 60 seconds to 3 directions of x, each 15 minutes 7 shock test to be measured after dropping from 60cm the concrete surface in packing state. note 1 : no dew condensation to be observed. note 2 : the function test shall be conducted after 4 hours storage at the normal temperature and humidity after removed from the test chamber. note 3 : vibration test will be conducted to the product itself without putting it in a container. e a g d c f 60cm concrete surface dropping method corner dropping e,f,g face : once b,c,d edge : once a corner : once face dropping edge dropping b
F-51430NFU-FW-AA ( aa ) no. 2001-0115 optrex corporation page 15 / 20 6. appearance standards 6.1. inspection conditions the lcd shall be inspected under 40w white fluorescent light. the distance between the eyes and the sample shall be more than 30cm. all directions for inspecting the sample should be within 45 against perpendicular line. 6.2. definition of applicable zones a zone : active display area b zone : area from outside of "a zone" to validity viewing area c zone : rest parts a zone + b zone = validity viewing area a zone b zone c zone bezel flame 45
F-51430NFU-FW-AA ( aa ) no. 2001-0115 optrex corporation page 16 / 20 6.3. standards no. parameter criteria 1 black and (1) round shape white spots, zone acceptable number foreign dimension (mm) a b c d 0.1 * * * 0.1 < d 0.2 3 5 * 0.2 < d 0.3 2 3 * 0.3 < d 0.35 0 1 * 0.35 < d 0 0 * d = ( long + short ) / 2 * : disregard (2) line shape zone acceptable number x (mm) y (mm) a b c - 0.03 3 w * * * 2.0 3 l 0.05 3 w 4 4 * 1.0 3 l 0.1 3 w 4 4 * - 0.1 < w in the same way (1) x : length y : width * : disregard total defects shall not exceed 7. 2 air bubbles (between glass zone acceptable number & polarizer) dimension (mm) a b c d1, d2 0.3 * * * 0.3 F-51430NFU-FW-AA ( aa ) no. 2001-0115 optrex corporation page 17 / 20 no. parameter criteria 3 the shape of dot (1) dot shape (with dent) as per the sketch of left hand. (2) dot shape (with projection) should not be connected to next dot. (3) pin hole (x+y) / 2 0.2mm (less than 0.1mm is no counted.) (4) deformation (x+y) / 2 0.2mm total acceptable number : 1/dot, 5/cell (defect number of (4) : 1pc.) 4 polarizer not to be conspicuous defects. 5 polarizer dirts if the stains are removed easily from lcdp surface, the defective. 6 complex foreign black spots, line shaped foreign substances or air bubbles substance glass & polarizer should be 7pcs maximum in total. 7 distance between d 0.2 : 20mm or more different foreign 0.2 F-51430NFU-FW-AA ( aa ) no. 2001-0115 optrex corporation page 18 / 20 7. code system of production lot the production lot of module is specified as follows. factory number (numeral) factory code (alphabet) production week (1~5) production month (1~9, x, y, z) production year (lower 2 digits) 8. type number the type number of module is specified on the back of module as follows. F-51430NFU-FW-AA seal 9. applying precautions please contact us when questions and/or new problems not specified in this pecifications arise.
F-51430NFU-FW-AA ( aa ) no. 2001-0115 optrex corporation page 19 / 20 10. precautions relating product handling the following precautions will guide you in handling our product correctly. 1) liquid crystal display devices 1. the liquid crystal display device panel used in the liquid crystal display module is made of plate glass. avoid any strong mechanical shock. should the glass break handle it with care . 2. the polarizer adhering to the surface of the lcd is made of a soft material. guard against scratching it. 2) care of the liquid crystal display module against static electricity discharge. 1. when working with the module, be sure to ground your body and any electrical equipment you may be using. we strongly recommend the use of anti static mats ( made of rubber ), to protect work tables against the hazards of electrical shock. 2. avoid the use of work clothing made of synthetic fibers. we recommend cotton clothing or other conductivity-treated fibers. 3. slowly and carefully remove the protective film from the lcd module, since this operation can generate static electricity. 3) when the lcd module alone must be stored for long periods of time: 1. protect the modules from high temperature and humidity. 2. keep the modules out of direct sunlight or direct exposure to ultraviolet rays. 3. protect the modules from excessive external forces. 4) use the module with a power supply that is equipped with an overcurrent protector circuit ,since the module is not provided with this protective feature. 5) do not ingest the lcd fluid itself should it leak out of a damaged lcd module. should hands or clothing come in contact with lcd fluid, wash immediately with soap. 6) conductivity is not guaranteed for models that use metal holders where solder connections between the metal holder and the pcb are not used. please contact us to discuss appropriate ways to assure conductivity. 7) for models which use cfl: 1. high voltage of 1000v or greater is applied to the cfl cable connector area. care should be taken not to touch connection areas to avoid burns. 2. protect cfl cables from rubbing against the unit and thus causing the wire jacket to become worn. 3.the use of cfls for extended periods of time at low temperatures will significantly shorten their service life. 8) for models which use touch panels: 1.do not stack up modules since they can be damaged by components on neighboring modules. 2.do not place heavy objects on top of the product. this could cause glass breakage. 9) for models which use cog,tab,or cof: 1.the mechanical strength of the product is low since the ic chip faces out unprotected from the rear. be sure to protect the rear of the ic chip from external forces. 2.given the fact that the rear of the ic chip is left exposed, in order to protect the unit from electrical damage, avoid installation configurations in which the rear of the ic chip runs the risk of making any electrical contact.
F-51430NFU-FW-AA ( aa ) no. 2001-0115 optrex corporation page 20 / 20 10) models which use flexible cable, heat seal, or tab: 1.in order to maintain reliability, do not touch or hold by the connector area. 2.avoid any bending, pulling, or other excessive force, which can result in broken connections. 11. warranty this product has been manufactured to your company ? s specifications as a part for use in your company ? s general electronic products. it is guaranteed to perform according to delivery specifications. for any other use apart from general electronic equipment, we cannot take responsibility if the product is used in medical devices, nuclear power control equipment, aerospace equipment, fire and security systems, or any other applications in which there is a direct risk to human life and where extremely high levels of reliability are required. if the product is to be used in any of the above applications, we will need to enter into a separate product liability agreement. 1. we cannot accept responsibility for any defect, which may arise from additional manufacturing of the product (including disassembly and reassembly), after product delivery. 2. we cannot accept responsibility for any defect, which may arise after the application of strong external force to the product. 3. we cannot accept responsibility for any defect, which may arise due to the application of static electricity after the product has passed your company ? s acceptance inspection procedures. 4. when the product is in cfl models, cfl service life and brightness will vary according to the performance of the inverter used, leaks, etc. we cannot accept responsibility for product performance, reliability, or defect, which may arise. 5. we cannot accept responsibility for in tellectual property of a third party , which may arise through the application of our product to your assembly with exception to those issues relating directly to the structure or method of manufacturing of our product. 6. optrex will not be held responsible for any quality guarantee issue for defect products judged as optrex-origin longer than 2 (two) years from optrex production or 1(one) year from optrex, optrex america, optrex europe , display lc delivery which ever comes later.


▲Up To Search▲   

 
Price & Availability of F-51430NFU-FW-AA

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X