v23990-p545-*2*-pm flowpim 0 600v/20a v geon 15 v v geoff 0 v r gon 16 r goff 8 figure 1 i gbt figure 2 fwd typical average static loss as a function of output current typical average static loss as a function of output current p loss = f(i out ) p loss = f(i out ) at at t j = 125 c t j = 125 c mi*cos from -1 to 1 in steps of 0,2 mi*cos from -1 to 1 in steps of 0,2 figure 3 i gbt figure 4 fwd typical average switching loss t ypical average switching loss as a function of output current p loss = f(i out ) as a function of output current p loss = f(i out ) at at t j = 125 c t j = 125 c dc link = 320 v dc link = 320 v f sw from 2 khz to 16 khz in steps of factor 2 f sw from 2 khz to 16 khz in steps of factor 2 = 3phase spwm general conditions output inverter application = = = mi*cosfi = -1 mi*cosfi = 1 0 10 20 30 40 0 5 10 15 20 25 30 35 i out (a) p loss (w) mi*cosf i= -1 mi*cosfi = 1 0 5 10 15 20 25 30 0 5 10 15 20 25 30 35 i out (a) p loss (w) f sw = 2khz f sw = 16khz 0 3 6 9 12 15 0 5 10 15 20 25 30 35 i out (a) p loss (w) f sw = 2khz f sw = 16khz 0 1 2 3 4 0 5 10 15 20 25 30 35 i out (a) p loss (w) copyright vincotech 1 revision: 3
v23990-p545-*2*-pm flowpim 0 600v/20a figure 5 phase figure 6 phase typical available 50hz output current t ypical available 50hz output current as a function mi*cos i out = f(mi*cos ) as a function of switching frequency i out = f(f sw ) at at t j = 125 c t j = 125 c dc link = 320 v dc link = 320 v f sw = 4 khz mi*cos = 0,8 t h from 60 c to 100 c in steps of 5 c t h from 60 c to 100 c in steps of 5 c figure 7 p hase figure 8 phase typical available 50hz output current as a function of typical available 0hz output current as a function mi*cos and switching frequency i out = f(f sw , mi*cos ) of switching frequency i outpeak = f(f sw ) at at t j = 125 c t j = 125 c dc link = 320 v dc link = 320 v t h = 80 c t h from 60 c to 100 c in steps of 5 c mi = 0 output inverter application th = 60c th = 100c 0 5 10 15 20 25 30 -1,0 -0,5 0,0 0,5 1,0 mi*cos i out (a) th = 60c th = 100c 0 5 10 15 20 25 30 1 10 100 fsw (khz) i out (a) 1 2 4 8 16 32 64 -1,00 -0,80 -0,60 -0,40 -0,20 0,00 0,20 0,40 0,60 0,80 1,00 i out (a) 27,0-30,0 24,0-27,0 21,0-24,0 18,0-21,0 15,0-18,0 mi*cosfi fsw (khz) th = 60c th = 100c 0 5 10 15 20 25 30 1 10 100 fsw (khz) i out ( apeak) copyright vincotech 2 revision: 3
v23990-p545-*2*-pm flowpim 0 600v/20a figure 9 inverter figure 10 inverter typical available peak output power as a function of typical efficiency as a function of output power heatsink temperature p out =f(t h ) efficiency=f(p out ) at at t j = 125 c t j = 125 c dc link = 320 v dc link = 320 v mi = 1 mi = 1 cos = 0,80 cos = 0,80 f sw from 2 khz to 16 khz in steps of factor 2 f sw from 2 khz to 16 khz in steps of factor 2 figure 11 i nverter typical available overload factor as a function of m otor power and switching frequency p peak / p nom =f(p nom ,f sw ) at t j = 125 c dc link = 320 v mi = 1 cos = 0,8 f sw from 1 khz to 16khz in steps of factor 2 t h = 80 c motor eff = 0,85 output inverter application 2khz 16khz 0 1 2 3 4 5 6 7 8 60 70 80 90 100 th ( o c) p out (kw) 2khz 16khz 96 97 98 99 100 0 1 2 3 4 5 6 7 8 9 p out (kw) efficiency (%) switching frequency (khz) 100 150 200 250 300 350 400 motor nominal power (hp/kw) overload (%) 1 399 266 160 0 0 0 2 399 266 160 0 0 0 4 399 266 160 0 0 0 8 399 266 160 0 0 0 16 370 247 148 0 0 0 2,00 / 1,47 3,00 / 2,21 5,00 / 3,68 7,50 / 5,52 10,00 / 7,36 15,00 / 11,03 copyright vincotech 3 revision: 3
|