Part Number Hot Search : 
VTO175 K1167 960508 9D160 5932B 1N4405 3225K30 RT8862
Product Description
Full Text Search
 

To Download LCCH-150X360 Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
  linkcom manufacturing co., ltd *,# =see notes below model specification ** * * * * (6)load regulation measured from 2 0% to full load. (7)line regulation measured from 1 00vac to 277vac. (8)preset accuracy measured at nor mal load, 120vac input. reference dimension (l*w*h): 8.2 * 2.83 * 1.52 inch (9)100% production tested. (5)minimum load is not required fo r proper operation . notes (1)all parameters not specially mentioned are measu red 230vac input. (2)all specifications typical @25 , unless otherwise noted, at normal line and load. (3)ripple and noise measured direc tly at pins/terminals at nom. load, 0.1uf bypass an d 47uf electrolytic, pk-pk @20mhz bandwidth. 2a/115vac 1a/230vac leakage current i/p-o/p 3.75kvac, o/p-grnd 0.5kvac, i/p-grnd 1.88kvac i/p-o/p, i/p-fg,o/p-fg :100m ohms / 500vdc / 25 / 70% rh 208.4 * 72 * 38.5 mm 8.2 * 2.83 * 1.52 inch dimensions(l*w*h) rohs compliant high operating ambient temp: -30 ~+60 (refer to output dreating curve) emc: ce / fcc comply with indoor/outdoor waterproof (ip 67) dimension (l*w*h): 208.4 * 72 * 38.55 mm withstand voltage isolation resistance storage temperature (4)specified for free-air convecti on cooling. *(9) short circuit protection will restart automatically after the fault condition is removed module : lcch-150  360 features output current(a) *(5) 90-305vac, 127-431vdc, normal 100-277vac protection: scp / otp / ovp power factor:>0.98@115vac;>0.95@230vac;@full load safety: ul / tuv / cb ce en55015 / fcc part15 over temp. protection emi temp. coefficient over v, protection relative humidity operating temp.*(4) pf>0.98 @115vac, pf>0.95@230vac at full load and ra ted output voltage cold start 65a @ 230vac safety ul 60950-1 / tuv en61347-2-13 / cb active power factor <0.45ma/264vac -40 to +80 10 to +90%, non-cond. 0.03% / (0-50 , typ) short circuit protection o/p noise (p-p, mv) *(3) ac current efficiency(typ @full load) setup,rise time(typ.) inrush current (typ) line regulation (%) *(7) hold up time dc output power input voltage range operating voltage range(v) load regulation (%) *(6) 25ms at full load 115vac/230vac range:47-63hz, normal 50-60hz input frequency 91% 2s,500ms at full load 115vac/230vac 30 min. model no. part no. power supply 208.4 * 72 * 38.55 mm 8.2 * 2.83 * 1.52 inch lcch-150  360 plcch1150  360 model name size ac input 90~305vac 1 preset accuracy (%) *(8) 1 lcch-150  360 norm. max. 1 -30 to +60 @full load(refer to output dreating curve) 151.2 w shut down and latch off o/p voltage , re-power on t o recover 36 4.2 500 www.linkcom.com.tw for more information, please contact with: sales@ linkcom.com.tw
linkcom manufacturing co., ltd model no. part no. power supply 208.4 * 72 * 38.55 mm 8.2 * 2.83 * 1.52 inch lcch-150  360 plcch1150  360 model name size reference unit :mm inch dimensions derate www.linkcom.com.tw for more information, please contact with :sales @ linkcom.com.tw


▲Up To Search▲   

 
Price & Availability of LCCH-150X360

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X