linkcom manufacturing co., ltd *,# =see notes below model specification ** * * * * (6)load regulation measured from 2 0% to full load. (7)line regulation measured from 1 00vac to 277vac. (8)preset accuracy measured at nor mal load, 120vac input. reference dimension (l*w*h): 8.2 * 2.83 * 1.52 inch (9)100% production tested. (5)minimum load is not required fo r proper operation . notes (1)all parameters not specially mentioned are measu red 230vac input. (2)all specifications typical @25 , unless otherwise noted, at normal line and load. (3)ripple and noise measured direc tly at pins/terminals at nom. load, 0.1uf bypass an d 47uf electrolytic, pk-pk @20mhz bandwidth. 2a/115vac 1a/230vac leakage current i/p-o/p 3.75kvac, o/p-grnd 0.5kvac, i/p-grnd 1.88kvac i/p-o/p, i/p-fg,o/p-fg :100m ohms / 500vdc / 25 / 70% rh 208.4 * 72 * 38.5 mm 8.2 * 2.83 * 1.52 inch dimensions(l*w*h) rohs compliant high operating ambient temp: -30 ~+60 (refer to output dreating curve) emc: ce / fcc comply with indoor/outdoor waterproof (ip 67) dimension (l*w*h): 208.4 * 72 * 38.55 mm withstand voltage isolation resistance storage temperature (4)specified for free-air convecti on cooling. *(9) short circuit protection will restart automatically after the fault condition is removed module : lcch-150 360 features output current(a) *(5) 90-305vac, 127-431vdc, normal 100-277vac protection: scp / otp / ovp power factor:>0.98@115vac;>0.95@230vac;@full load safety: ul / tuv / cb ce en55015 / fcc part15 over temp. protection emi temp. coefficient over v, protection relative humidity operating temp.*(4) pf>0.98 @115vac, pf>0.95@230vac at full load and ra ted output voltage cold start 65a @ 230vac safety ul 60950-1 / tuv en61347-2-13 / cb active power factor <0.45ma/264vac -40 to +80 10 to +90%, non-cond. 0.03% / (0-50 , typ) short circuit protection o/p noise (p-p, mv) *(3) ac current efficiency(typ @full load) setup,rise time(typ.) inrush current (typ) line regulation (%) *(7) hold up time dc output power input voltage range operating voltage range(v) load regulation (%) *(6) 25ms at full load 115vac/230vac range:47-63hz, normal 50-60hz input frequency 91% 2s,500ms at full load 115vac/230vac 30 min. model no. part no. power supply 208.4 * 72 * 38.55 mm 8.2 * 2.83 * 1.52 inch lcch-150 360 plcch1150 360 model name size ac input 90~305vac 1 preset accuracy (%) *(8) 1 lcch-150 360 norm. max. 1 -30 to +60 @full load(refer to output dreating curve) 151.2 w shut down and latch off o/p voltage , re-power on t o recover 36 4.2 500 www.linkcom.com.tw for more information, please contact with: sales@ linkcom.com.tw
linkcom manufacturing co., ltd model no. part no. power supply 208.4 * 72 * 38.55 mm 8.2 * 2.83 * 1.52 inch lcch-150 360 plcch1150 360 model name size reference unit :mm inch dimensions derate www.linkcom.com.tw for more information, please contact with :sales @ linkcom.com.tw
|