![]() |
|
If you can't view the Datasheet, Please click here to try to view without PDF Reader . |
|
Datasheet File OCR Text: |
x x r r p p 6 6 6 6 7 7 0 0 3 3 a a 3 3 0 0 0 0 k k h h z z - - 2 2 . . 5 5 m m h h z z s s y y n n c c h h r r o o n n o o u u s s s s t t e e p p d d o o w w n n r r e e g g u u l l a a t t o o r r june 2013 rev. 1.0. 1 exar corporation www.exar.com 48720 kato road, fremont ca 94538, usa tel. +1 510 668-7000 C fax. +1 510 668-7001 general description the xrp6670 is a synchronous current mode pwm step-down (buck) regulator capable of delivering up to 3 amps. a 2.6v to 5.5v input voltage range allows for single supply operation from industry standard 3.3v and 5v power rails. based on a current mode pwm control scheme, the xrp6670 operating frequency is programmable between 300khz and 2.5mhz via an external resistor. this flexibility allows the xrp6670 to optimize component selection and reduce component count and solution footprint. it provides a low output voltage ripple, excellent line and load regulation and has a 100% duty cycle ldo mode. output voltage is adjustable to as low as 0.8v with a better than 2% accuracy while a low quiescent current supports the most stringent battery operating conditions. built-in over-temperature, overcurrent, short circuit and under-voltage lock-out protections insure safe operations under abnormal operating conditions. the xrp6670 is offered in a rohs compliant, green/halogen free 3mmx3mm 10-pin dfn package. applications industrial & medical equipment audio-video equipment networking & telecom equipment portable/battery operated equipment features guaranteed 3a output current - input voltage: 2.6v to 5.5v prog. pwm current mode control - programmable 300khz to 2.5mhz - 100% duty cycle ldo mode operation - achieves 95% efficiency adjustable output voltage range - 0.8v to 5v with 2% accuracy enable and power good functions 460a quiescent current over-temperature, over-current, short-circuit and uvlo protections rohs compliant green/halogen free 3mm x 3mm 10-pin dfn package typical application diagram fig. 1: xrp6670 application diagram
x x r r p p 6 6 6 6 7 7 0 0 3 3 a a 3 3 0 0 0 0 k k h h z z - - 2 2 . . 5 5 m m h h z z s s y y n n c c h h r r o o n n o o u u s s s s t t e e p p d d o o w w n n r r e e g g u u l l a a t t o o r r ? 2013 exar corporation 2/13 rev. 1.0.1 absolute maximum ratings these are stress ratings only and functional operat ion of the device at these ratings or any other above thos e indicated in the operation sections of the specific ations below is not implied. exposure to absolute maximum rating conditions for extended periods of time may affect reliability. v dd , pv dd , fb, comp, shdn/rt ................... -0.3v to 6. 0v sw ................................................ ... -0.3v to v dd +0.3v junction temperature range ........................ ....... +150c storage temperature .............................. -65c to 150c power dissipation ................................ internally limited lead temperature (soldering, 10 sec) .............. ..... 260c esd rating (hbm - human body model) ............... ..... 2kv esd rating (mm - machine model) ................... ........ 200v operating ratings input voltage range v in ............................... 2.6v to 5.5v maximum output current (min.) ..................... ............ 3a junction temperature range ................. -40c to +125c thermal resistance ................................ ...................... dfn10 ja .................................................. ..110c/w dfn10 jc .................................................. ..... 3c/w note 1: t j is a function of the ambient temperature t a and power dissipation p d : (t j = t a + (p d * ja )) electrical specifications specifications are for an operating junction temper ature of t a = t j = 25c only; limits applying over the full operati ng junction temperature range are denoted by a ?. mi nimum and maximum limits are guaranteed through tes t, design, or statistical correlation. typical values represent t he most likely parametric norm at t j = 25c, and are provided for reference purposes only. unless otherwise indicated, v dd = v pvdd = 3.3v, t a = t j = 25c. parameter min. typ. max. units conditions supply current 460 a v fb =0.75v, no switching shutdown supply current 1 a shdn/rt=v dd =v pvdd =5.5v under voltage lockout (uvlo) threshold 2.2 v v dd rising under voltage lockout (uvlo) hysteresis 300 mv feedback voltage v fb 0.784 0.800 0.816 v fb pin bias current 0.1 0.4 a current sense transresistance 0.2 ? switching leakage current 1 a shdn/rt=v dd =5.5v error amplifier voltage gain 800 v/v error amplifier trans- conductance 800 a/v rt pin voltage 0.760 0.800 0.840 v switching frequency range 0.3 2.5 mhz programmed via r osc 0.8 1 1.2 r osc =330k? maximum duty cycle 100 % v fb =0.75v minimum on-time 120 150 ns switch current limit 3.2 4.2 a v fb =0.75v switching fet on resistance 0.11 0.16 ? i sw =500ma synchronous fet on resistance 0.11 0.17 ? i sw =500ma shutdown threshold v dd -0.7 v dd -0.4 v pgood voltage range -15 +15 % pgood pull down resistance 120 ? output current 3 a v dd = 2.6v to 5.5v, v out = 2.5v output voltage line regulation 0.4 %/v v dd = 2.7v to 5.5v, i out = 100ma output voltage load regulation 0.2 % i out = 10ma to 3a soft start time 1.5 ms i out = 10ma thermal shutdown temperature 160 c thermal shutdown hysteresis 20 c x x r r p p 6 6 6 6 7 7 0 0 3 3 a a 3 3 0 0 0 0 k k h h z z - - 2 2 . . 5 5 m m h h z z s s y y n n c c h h r r o o n n o o u u s s s s t t e e p p d d o o w w n n r r e e g g u u l l a a t t o o r r ? 2013 exar corporation 3/13 rev. 1.0.1 block diagram fig. 2: xrp6670 block diagram pin assignment fig. 3: xrp6670 pin assignment x x r r p p 6 6 6 6 7 7 0 0 3 3 a a 3 3 0 0 0 0 k k h h z z - - 2 2 . . 5 5 m m h h z z s s y y n n c c h h r r o o n n o o u u s s s s t t e e p p d d o o w w n n r r e e g g u u l l a a t t o o r r ? 2013 exar corporation 4/13 rev. 1.0.1 pin description name pin number description shdn/rt 1 shutdown and oscillator resistor input. connect a resistor to gnd from this pin to set the switching frequency. forcing this pin to vdd shuts down the device. gnd 2 signal ground. all small-signal ground, such as the compensation c omponents and exposed pad should be connected to this, which in turn connects to pgn d at one point. sw 3, 4 power switch output pin. this pin is connected to the inductor. pgnd 5 power ground signal. connect this signal as close as possible to the inp ut and output capacitors c in and c out . pvdd 6 power input supply pin. decouple this pin to pgnd (pin 5) with a capacitor. vdd 7 signal input supply pin. decouple this pin to gnd (pin 2) with a capacitor. typically, vdd and pvdd are connected together. pgood 8 power good flag. this is an open drain output and is pulled to groun d if the output voltage is out of regulation. fb 9 feedback pin. an external resistor divider connected to fb progra ms the output voltage. comp 10 compensation pin. this is the output of transconductance error amplif ier and the input to the current comparator. it is used to compensate the control lo op. connect an rc ne twork form this pin to gnd. exp. pad exp. pad connect to gnd signal (pin 2). ordering information part number junction temperature range marking package packing quantity note 1 note 2 xrp6670ehtr-f -40ct j +125c 6670 yyww xxx dfn10 3k/tape & reel halogen free XRP6670EVB xrp6670 evaluation board yy = year C ww = work week C x = lot number; when applicable. x x r r p p 6 6 6 6 7 7 0 0 3 3 a a 3 3 0 0 0 0 k k h h z z - - 2 2 . . 5 5 m m h h z z s s y y n n c c h h r r o o n n o o u u s s s s t t e e p p d d o o w w n n r r e e g g u u l l a a t t o o r r ? 2013 exar corporation 5/13 rev. 1.0.1 typical performance characteristics all data taken at v in = v dd = v pvdd = 3.3v, t j = t a = 25c, unless otherwise specified - schematic and bom from application information section of this datasheet. fig. 4: supply current versus input voltage fig. 5: supply current versus ambient temperature fig. 6: efficiency versus output current fig. 7: pmos rds on resistance versus ambient temperature fig. 8: nmos rds on resistance versus ambient temperature fig. 9: frequency versus ambient temperature x x r r p p 6 6 6 6 7 7 0 0 3 3 a a 3 3 0 0 0 0 k k h h z z - - 2 2 . . 5 5 m m h h z z s s y y n n c c h h r r o o n n o o u u s s s s t t e e p p d d o o w w n n r r e e g g u u l l a a t t o o r r ? 2013 exar corporation 6/13 rev. 1.0.1 fig. 10: v fb versus ambient temperature fig. 11: current limit versus ambient temperature fig. 12: start-up from vin v in =3.3v, v out =2.5v, i out =3a fig. 13: load transient response v in =5v, v out =2.5v, i out =0a to 3a fig. 14: short circuit protection v in =3.3v, v out =2.5v fig. 15: short circuit recovery v in =3.3v, v out =2.5v x x r r p p 6 6 6 6 7 7 0 0 3 3 a a 3 3 0 0 0 0 k k h h z z - - 2 2 . . 5 5 m m h h z z s s y y n n c c h h r r o o n n o o u u s s s s t t e e p p d d o o w w n n r r e e g g u u l l a a t t o o r r ? 2013 exar corporation 7/13 rev. 1.0.1 theory of operation functional description the xrp6670 is a synchronous, current-mode, step-down regulator. it regulates input voltages from 2.6v to 5.5v and supplies up to 3a of output current i out . the xrp6670 uses current-mode control to regulate the output voltage v out . the v out is measured at fb through a resistive voltage divider and input to a transconductance error amplifier. the high- side switch current is compared to the output of the error amplifier to control the output voltage. the regulator utilizes internal p- channel and n-channel mosfets to step-down the input voltage. because the high-side fet is p-channel a bootstrapping capacitor is not necessary and the regulator can operate at 100% duty cycle. the xrp6670 has several powerful protection features including ocp, otp, uvlo and output short-circuit. short - circuit and over - current protection ocp the xrp6670 protects itself and downstream circuits against accidental increase in current or short-circuit. if peak current through the switching fet increases above 4.2a (nominal) the regulator enters an idle state where the internal fets are turned off and softstart is pulled low. after a period of 2000xt the regulator will attempt a softstart. if the high current persists the protection cycle will repeat. soft - start xrp6670 has an integrated soft-start which is preset at 1.5ms (nominal). this feature limits the inrush current during startup and allows the output voltage to smoothly rise to its programmed value. power good flag this open drain output (pgood) can be used to monitor whether the output voltage is within regulation (15%). pgood is pulled to ground when v out is not in regulation. pgood should be tied to vdd with a 100k resistor. programmable frequency the switching frequency is programmable within a range of 300khz to 2.5mhz via a resistor placed between shdn/rt and gnd pins. an equation for calculating a resistor value for a target frequency is given the application information section. 100% duty cycle and ldo operation the xrp6670 switching fet is a p-channel device and therefore can operate at 100% duty cycle. in battery operated applications where v in will droop, xrp6670 can seamlessly transition from pwm to ldo mode. over - temperature protection otp if the junction temperature exceeds 160c the otp circuit is triggered, turning off the internal control circuit and fets. when junction temperature drops below 140c the xrp6670 will restart. although thermal shutdown is built-in in the xrp6670 to protect the device from thermal damage, the total power dissipation that the xrp6670 can sustain is based on the package thermal capability. equation 1 shown on page two, can be used to calculate junction temperature and ensure operation within the recommended maximum temperature of 125c. application information programming the output voltage use an external resistor divider to set the output voltage based on the following equation: 2 1 0.800 1 where: r1 is the resistor between v out and fb (nominally set at 100k?) x x r r p p 6 6 6 6 7 7 0 0 3 3 a a 3 3 0 0 0 0 k k h h z z - - 2 2 . . 5 5 m m h h z z s s y y n n c c h h r r o o n n o o u u s s s s t t e e p p d d o o w w n n r r e e g g u u l l a a t t o o r r ? 2013 exar corporation 8/13 rev. 1.0.1 r2 is the resistor between fb and gnd 0.800v is the nominal feedback voltage a resistor selection guide for common values of v out is shown in table 1. vout r1(k?) r2(k?) 1.1v 100 267 1.2v 100 200 1.5v 105 120 1.8v 120 95.3 2.5v 100 47 2.8v 75 30 3.3v 75 24 table 1: resistor selection programming the frequency use resistor r osc between shdn/rt and gnd pins to program the switching frequency. a graph of nominal frequency versus r osc is shown in figure 16. fig. 16: frequency versus r osc the following equation closely fits the empirical data and can be used to select r osc for a given frequency. . . duty - cycle limitation xrp6670 has a minimum on-time specification of 150ns which imposes a restriction on minimum duty-cycle (see table 2) f (mhz) t typ (ns) t min (ns) duty-cycle min 1.0 1000 800 0.19 2.0 500 400 0.38 table 2: minimum duty-cycle arising from minimum on-time) for example if frequency is set at 2mhz then typical switching period is 500ns. allowing a 20% uncertainty, minimum period is 400ns and corresponding minimum duty-cycle is 0.38. recall that for a buck regulator duty- cycle=v out /v in . therefore when operating at 2mhz with v in of 5v, a v out 1.9v is not possible (5v x 0.38 = 1.9v). output inductor select the output inductor for inductance l, dc current rating i dc and saturation current rating i sat . i dc should be larger than regulator output current. i sat , as a rule of thumb, should be 50% higher than the regulator output current. since the regulator is rated at 3a then i dc 3a and i sat 4.5a. please note that peak switch current is rated at 3.2a minimum. therefore applications that require an output current of 3a should limit the peak-to-peak inductor current ripple to ?i l 0.4a. in the following we will use the common practice of ?i l 1a. therefore worst- case maximum output current will be limited to i out =3.2a-0.5a=2.7a. calculate the inductance from: where: ?i l is peak-to-peak inductor current ripple nominally set to 30% of i out f s is nominal switching frequency as an example, inductor values corresponding to 5v in /1mhz and 3.3v in /1mhz are shown in tables 3 and 4 for several common output x x r r p p 6 6 6 6 7 7 0 0 3 3 a a 3 3 0 0 0 0 k k h h z z - - 2 2 . . 5 5 m m h h z z s s y y n n c c h h r r o o n n o o u u s s s s t t e e p p d d o o w w n n r r e e g g u u l l a a t t o o r r ? 2013 exar corporation 9/13 rev. 1.0.1 voltages. note that example inductors shown in tables 3 and 4 are wurth shielded inductors. vout(v) ?i l(p-p) (a) l(h) inductor example 3.3 0.76 1.5 74437346015 2.8 0.81 1.5 74437346015 2.5 0.84 1.5 74437346015 1.8 0.76 1.5 74437346015 1.5 0.70 1.5 74437346015 1.2 0.62 1.5 74437346015 1.1 0.57 1.5 74437346015 table 3: suggested inductor values for f=1mhz, v in =5v and i out =2.7a vout(v) ?i l(p-p) (a) l(h) inductor example 2.5 0.41 1.5 74437346015 1.8 0.54 1.5 74437346015 1.5 0.54 1.5 74437346015 1.2 0.51 1.5 74437346015 1.1 0.49 1.5 74437346015 table 4: suggested inductor values for f=1mhz, v in =3.3v and i out =2.7a output capacitor c out select the output capacitor for voltage rating, capacitance c out and equivalent series resistance esr. the voltage rating, as a rule of thumb, should be at least twice the output voltage. when calculating the required capacitance, usually the overriding requirement is current load-step transient. if the unloading transient (i.e., when load transitions from a high to a low current) is met, then usually the loading transient (when load transitions from a low to a high current) is met as well. therefore calculate the c out based on the unloading transient requirement from: where: l is the inductance calculated in the preceding step i high is the value of load-step prior to unloading. this is nominally set equal to regulator current rating (3a). i low is the value of load-step after unloading. this is nominally set equal to 50% of regulator current rating (1.5a). v transient is the maximum permissible voltage transient corresponding to the load step mentioned above. v transient is typically specified from 3% to 5% of v out . esr of the capacitor has to be selected such that the output voltage ripple requirement ?v out , nominally 1% of v out , is met. voltage ripple ?v out is mainly composed of two components: the resistive ripple due to esr and capacitive ripple due to c out charge transfer. for applications requiring low voltage ripple, ceramic capacitors are recommended because of their low esr which is typically in the range of 5m?. therefore ?v out is mainly capacitive. for ceramic capacitors calculate the ?v out from: 8 where: ?i l is from table 2 or 3 c out is the value calculated above f s is nominal switching frequency if tantalum or electrolytic capacitors are used then ?v out is essentially a function of esr: input capacitor c in select the input capacitor for voltage rating, rms current rating and capacitance. the voltage rating should be at least 50% higher than the regulators maximum input voltage. calculate the capacitors current rating from: , 1 where: i out is regulators maximum current (3a) d is duty cycle (d=v out /v in ) calculate the c in capacitance from: x x r r p p 6 6 6 6 7 7 0 0 3 3 a a 3 3 0 0 0 0 k k h h z z - - 2 2 . . 5 5 m m h h z z s s y y n n c c h h r r o o n n o o u u s s s s t t e e p p d d o o w w n n r r e e g g u u l l a a t t o o r r ? 2013 exar corporation 10/13 rev. 1.0.1 where: ?v in is the permissible input voltage ripple, nominally set at 1% of v in loop compensation xrp6670 utilizes current-mode control. this allows using a minimum of external components to compensate the regulator. in general only two components are needed: rc and cc. proper compensation of the regulator (determining rc and cc) results in optimum transient response. in terms of power supply control theory, the goals of compensation are to choose rc and cc such that the regulator loop gain has a crossover frequency fc equal to 10% of switching frequency. the corresponding phase-margin should be between 45 degrees and 65 degrees. an important characteristic of current-mode buck regulator is its dominant pole. the frequency of the dominant pole is given by: 1 2 where r load is the output load resistance. the uncompensated regulator has a constant gain up to its pole frequency, beyond which the gain decreases at -20db/decade. the zero arising from the output capacitors esr is inconsequential if ceramic c out is used. this simplifies the compensation. the rc and cc, which are placed between the output of xrp6670s error amplifier and ground, constitute a zero. the frequency of this compensating zero is given by: 1 2 for the typical application circuit shown in this datasheet, rc=10k? and cc=1nf provide a satisfactory compensation. please use exar application note for compensating other application circuits. x x r r p p 6 6 6 6 7 7 0 0 3 3 a a 3 3 0 0 0 0 k k h h z z - - 2 2 . . 5 5 m m h h z z s s y y n n c c h h r r o o n n o o u u s s s s t t e e p p d d o o w w n n r r e e g g u u l l a a t t o o r r ? 2013 exar corporation 11/13 rev. 1.0.1 typical applications 5v to 3.3v conversion C 1mh z fig. 17: 3.5v-5.5v to 3.3v conversion 1mhz switching operations 5v to 3.3v conversion C 2.5mh z fig. 18: 4v-5.5v to 3.3v conversion 2.5mhz switching operations x x r r p p 6 6 6 6 7 7 0 0 3 3 a a 3 3 0 0 0 0 k k h h z z - - 2 2 . . 5 5 m m h h z z s s y y n n c c h h r r o o n n o o u u s s s s t t e e p p d d o o w w n n r r e e g g u u l l a a t t o o r r ? 2013 exar corporation 12/13 rev. 1.0.1 package specification 3 mm x 3 mm dfn-10 x x r r p p 6 6 6 6 7 7 0 0 3 3 a a 3 3 0 0 0 0 k k h h z z - - 2 2 . . 5 5 m m h h z z s s y y n n c c h h r r o o n n o o u u s s s s t t e e p p d d o o w w n n r r e e g g u u l l a a t t o o r r ? 2013 exar corporation 13/13 rev. 1.0.1 revision history revision date description 1.0.0 03/19/2013 initial release of datasheet 1.0.1 06/20/2013 corrected cc=1nf on page 10 for further assistance email: customersupport@exar.com powertechsupport@exar.com exar technical documentation: http://www.exar.com/ techdoc/default.aspx? e xar c orporation h eadquarters and s ales o ffices 48720 kato road fremont, ca 94538 C usa tel.: +1 (510) 668-7000 fax: +1 (510) 668-7030 www.exar.com notice exar corporation reserves the right to make changes to the products contained in this publication in o rder to improve design, performance or reliability. exar corporatio n assumes no responsibility for the use of any circ uits described herein, conveys no license under any patent or other right, and makes no representation that the circuits are free of patent infringement. charts and schedules contained herein are only for illustration purposes and may vary de pending upon a users specific application. while the information in this publication has been carefully checked; no responsibility, however, is assumed for inaccuracies. exar corporation does not recommend the use of any of its products in life support applications where the failure or malfunction of the product can reasonably be expect ed to cause failure of the life support system or t o significantly affect its safety or effectiveness. products are not authorize d for use in such applications unless exar corporat ion receives, in writing, assurances to its satisfaction that: (a) t he risk of injury or damage has been minimized; (b) the user assumes all such risks; (c) potential liability of exar corpora tion is adequately protected under the circumstance s. reproduction, in part or whole, without the prior w ritten consent of exar corporation is prohibited. |
Price & Availability of XRP6670EVB
![]() |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |