40 condor d.c. power supplies, inc., 2311 statham parkway, oxnard, ca 93033 800-235-5929 ? 805-486-4565 fax 805-487-8911 www.condorpower.com glc75 commercial/ glm75 medical 75 watt single output global performance switchers features: cost-effective single-output power source 3.4" x 5.75" x 1.56" (meets 1u applications) universal input 90-264 vac 2-year warranty complies with en61000-3-2 class a also available in multiple output versions conducted emi exceeds fcc class b and cispr 22 class b (commercial models) and cispr 11 class b (medical models) commercial approved to ul1950, csa22.2 no. 234 and iec950, en60950 medical approved to ul2601-1, iec601-1 and csa22.2 no. 601 specifications: ac input 90-264 vac, 47-63 hz single phase. input current maximum input current at 120 vac, 60 hz with full rated output load not to exceed 2.3 a. output power normal continuous output power is 75 w for unrestricted natural convection cooling; 110 w with 26 cfm airflow. output regulation regulation measured by changing from 5% to 50% load or 50% load to full load in either direction. overload protection factory set to begin power limiting at approximately 120 w (glc 75-5 is set at approximately 100 w). fully protected against short circuit and output overload. short circuit protection is cycling type power limit. output noise 0.5% rms, 1% pk-pk, 20 mhz bandwidth, differential mode. measured with noise probe directly across output terminals of the power supply. transient response main output: 500 s typical response time for return to within 0.5% of final value for a 50% load step change, ? i/ ? t<0.2 a/s. maximum voltage deviation is 3.5%. startup/ shutdown overshoot less than 3%. overvoltage protection standard on all models. voltage adjust factory set on standard unit; however, potentiometer adjusts voltage 5% minimum. consult factory for application assistance. efficiency 72-85% depending on model. input protection internal ac fuse provided. designed to blow only if a catastrophic failure occurs in the unit ? fuse does not blow on overload or short circuit. marked to lvd inrush current inrush limited by internal thermistors. inrush at 240 vac, averaged over the first ac half-cycle under cold start conditions will not exceed 37 a. temperature coefficient 0.03%/ c typical on all outputs. power fail a standard ttl or cmos compatible output goes low (< 0.5 v) 5ms before output voltage drops more than 4% below nominal voltage upon loss of ac power. signal is factory set to trip on 84 to 94 vac brown-out depending upon incoming line impedance and distortion. other settings are available through adjustment of built-in potentiometer (consult factory for assistance). output will stay low for 20 ms minimum. emi/emc compliance all models include built-in emi filtering to meet the following emissions requirements: emi specifications compliance level conducted emissions glc75 en55022 class b; fcc class b conducted emissions glm75 en55011 class b; fcc class b static discharge en61000-4-2, 6 kv contact, 8 kv air rf field susceptibility en61000-4-3, 3 v/meter fast transients/bursts en61000-4-4, 2 kv, 5 khz surge susceptibility en61000-4-5, 1 kv diff., 2 kv com. line frequency harmonics en61000-3-2 class a commercial safety all glc models are approved to ul1950, csa22.2 no. 234 level 3, iec950 and en60950. consult factory for approval status. medical leakage current 70 a 264 v @ 50 hz (normal conditions). medical safety all glm models are approved to ul2601-1, csa-c22.2 no. 601.1, iec601-1 and en60601-1. consult factory for approval status.
41 condor d.c. power supplies, inc., 2311 statham parkway, oxnard, ca 93033 800-235-5929 805-486-4565 fax 805-487-8911 www.condorpower.com glc75 commercial/ glm75 medical 75 watt single output glc75/ glm75 mechanical specifications a. rating with unrestricted convection cooling. total power not to exceed 75 w. b. rating with 26 cfm forced-air cooling. total power not to exceed 110 w. l a i c r e m m o c l e d o m l a c i d e m l e d o m t u p t u o t u p t u o m u m i n i m m u m i x a m t u p t u o ) a ( m u m i x a m t u p t u o ) b ( t u p t u o k a e p t e s p v o 1 v p - p e s i o n l a t o t n o i t a l u g e r 5 - 5 7 c l g 5 - 5 7 m l g v 1 . 5a 0a 7 . 3 1a 6 . 9 1a 1 2v 6 . 0 2 . 6v m 0 5% 1 2 1 - 5 7 c l g 2 1 - 5 7 m l g v 2 1a 0a 3 . 6a 1 . 9a 5 . 9v 1 . 1 6 . 5 1v m 0 2 1% 1 5 1 - 5 7 c l g 5 1 - 5 7 m l g v 5 1a 0a 5a 3 . 7a 7 . 7v 5 . 1 5 . 8 1v m 0 5 1% 1 4 2 - 5 7 c l g 4 2 - 5 7 m l g v 4 2a 0a 1 . 3a 6 . 4a 5v 5 . 2 8 2v m 0 4 2% 1 8 2 - 5 7 c l g 8 2 - 5 7 m l g v 8 2a 0a 7 . 2a 4a 4 . 4v 8 . 2 4 3v m 0 8 2% 1 a. units should be allowed to warm up/operate under non-condensing conditions before application of power. b. random vibration ? 10 to 2000hz, 6db/octave roll-off from 350 to 2000hz, 3 orthogonal axes. tested for 10 min./axis operating and 1 hr./axis non-operating. c. shock testing ? half-sinusoidal, 10 3 ms duration, direction, 3 orthogonal axes, total 6 shocks. l a t n e m n o r i v n e n o i t a c i f i c e p s g n i t a r e p o g n i t a r e p o - n o n ) a ( e r u t a r e p m e t 0 5 o t 0 o c 5 8 + o t 0 4 - o c ) a ( y t i d i m u hh r % 5 9 o t 0h r % 5 9 o t 0 ) b ( k c o h sg 0 2 k p g 0 4 k p e d u t i t l at f 0 0 0 , 0 1 o t 0 0 5 -t f 0 0 0 , 0 4 o t 0 0 5 - ) c ( n o i t a r b i vg 5 . 1 s m r g 3 0 0 . 0 , 2 z h /g 5 s m r g 6 2 0 . 0 , 2 z h /
|