02/13/2015 012701 - hpl-ed2014 v9.0 en 1 / 12 contactor,?4p,?4kw/400v/ac3 part?no. ? DILEM4-G(24vdc) article?no.? 012701 catalog?no.? xtmf9a00td delivery?programme product range ? ? contactors application ? ? mini contactors for motors and resistive loads subrange ? ? dilem contactors utilization category ? ? ac-1: nicht induktive oder schwach induktive last, widerstands?fen ac-3: k?figl?ufermotoren: anlassen, ausschalten w?hrend des laufes ac-4: k?figl?ufermotoren: anlassen, gegenstrombremsen, reversieren, tippen connection technique ? ? screw terminals pole ? ? 4 pole rated?operational?current ? ? ? ac-3 ? ? ? 380 v 400 v i e a 9 ac-1 ? ? ? conventional free air thermal current, 3 pole, 50 - 60 hz ? ? ? open ? ? ? at 40 c i th =i e a 22 max.?rating?for?three-phase?motors,?50?-?60?hz ? ? ? ac-3 ? ? ? 220 v 230 v p kw 2.2 380 v 400 v p kw 4 660 v 690 v p kw 4 ac-4 ? ? ? 220 v 230 v p kw 1.5 380 v 400 v p kw 3 660 v 690 v p kw 3 contact sequence ? ? for use with ? ? dilem dile actuating voltage ? ? 24 v dc voltage ac/dc ? ? dc operation technical?data general standards ? ? iec/en 60947, vde 0660, csa, ul maximum operating frequency ? ? ? mechanical ? ops./h 9000 electrical (contactors without overload relay) ? ? page 05/070 climatic proofing ? ? damp heat, constant, to iec 60068-2-78 damp heat, cyclic, to iec 60068-2-30 ambient temperature ? c ? open ? c - 25 - 50 enclosed ? c - 25 - 40 mounting position ? ? as required, except vertical with terminals a1/a2 at the bottom
02/13/2015 012701 - hpl-ed2014 v9.0 en 2 / 12 mounting position ? ? mechanical shock resistance (iec/en 60068-2-27) ? ? ? half-sinusoidal shock, 10 ms ? ? ? basic unit without auxiliary contact module ? ? ? main contacts, make contacts ? g 10 basic unit with auxiliary contact module ? ? ? main contacts make contact ? g ? make ? g 10 auxiliary contacts make/break contacts ? g 20 / 20 degree of protection ? ? ip20 protection against direct contact when actuated from front (en 50274) ? ? finger and back-of-hand proof weight ? kg 0.17 terminal capacity of auxiliary and main contacts ? ? ? screw terminals ? ? ? solid ? mm 2 1 x (0.75 - 2.5) 2 x (0.75 - 2.5) flexible with ferrule ? mm 2 1 x (0.75 - 1.5) 2 x (0.75 - 1.5) solid or stranded ? awg 18 - 14 terminal screw ? ? m3.5 pozidriv screwdriver ? size 2 standard screwdriver ? mm 0.8 x 5.5 1 x 6 max. tightening torque ? nm 1.2 main?conducting?paths rated impulse withstand voltage u imp v ac 6000 overvoltage category/pollution degree ? ? iii/3 rated insulation voltage u i v ac 690 rated operational voltage u e v ac 690 safe isolation to en 61140 ? ? ? between coil and contacts ? v ac 300 between the contacts ? v ac 300 making capacity (cos ? to iec/en 60947) ? a 110 breaking capacity ? ? ? 220 v 230 v ? a 90 380 v 400 v ? a 90 500 v ? a 64 660 v 690 v ? a 42 short-circuit protection maximum fuse ? ? ? type 2 coordination gl/gg a 10 type 1 coordination gl/gg a 20 ac ac-1 ? ? ? rated operational current ? ? ? conventional free air thermal current, 3 pole, 50 - 60 hz ? ? ? open ? ? ? at 40 c i th =i e a 22 at 50 c i th =i e a 20 02/13/2015 012701 - hpl-ed2014 v9.0 en 3 / 12 at 55 c i th =i e a 19 enclosed i th a 16 notes ? ? at maximum permissible ambient air temperature. conventional free air thermal current, 1 pole ? ? ? notes ? ? at maximum permissible ambient air temperature. open i th a 60 enclosed i th a 50 ac-3 ? ? ? rated operational current ? ? ? open, 3-pole: 50 C?60 hz ? ? ? notes ? ? at maximum permissible ambient air temperature. 220 v 230 v i e a 9 240 v i e a 9 380 v 400 v i e a 9 415 v i e a 9 440v i e a 9 500 v i e a 6.4 660 v 690 v i e a 4.8 motor rating p kwh ? 220 v 230 v p kw 2.2 240v p kw 2.5 380 v 400 v p kw 4 415 v p kw 4.3 440 v p kw 4.6 500 v p kw 4 660 v 690 v p kw 4 ac-4 ? ? ? rated operational current ? ? ? open, 3-pole: 50 C?60 hz ? ? ? notes ? ? at maximum permissible ambient air temperature. 220 v 230 v i e a 6.6 240 v i e a 6.6 380 v 400 v i e a 6.6 415 v i e a 6.6 440 v i e a 6.6 500 v i e a 5 660 v 690 v i e a 3.4 motor rating p kwh ? 220 v 230 v p kw 1.5 240 v p kw 1.8 380 v 400 v p kw 3 415 v p kw 3.1 440 v p kw 3.3 500 v p kw 3 660 v 690 v p kw 3 dc rated operational current open ? ? ? dc - -1 ? ? ? 12 v i e a 20 24 v i e a 20 60 v i e a 20 110 v i e a 20 220 v i e a 20 dc - 3 ? ? ? 02/13/2015 012701 - hpl-ed2014 v9.0 en 4 / 12 12 v i e a 8 24 v i e a 8 60 v i e a 4 110 v i e a 3 220 v i e a 1 dc - 5 ? ? ? 12 v i e a 2.5 24 v i e a 2.5 60 v i e a 2.5 110 v i e a 2.5 220 v i e a 1 current heat losses (3- or 4-pole) ? ? ? to i th ? w 4.7 magnet?systems voltage tolerance ? ? ? dc operated ? ? ? pick-up voltage ? ? 0.85 ? 1.1 power consumption ? ? ? dc operation ? ? ? power consumption pick-up = sealing ? va/w 2.6 notes ? ? smoothed dc voltage or three-phase bridge rectifier duty factor ? % df 100 switching times at 100 % u c ? ? ? make contact ? ms ? closing delay ? ms ? closing delay min. ? ms 26 closing delay max. ? ms 35 opening delay ? ms ? opening delay min. ? ms 15 opening delay max. ? ms 25 closing delay with top mounting auxiliary contact ? ms max. 70 reversing contactors ? ? ? changeover time at 110 % u c ? ? ? changeover time min. ? ms 40 changeover time max. ? ms 50 arcing time at 690 v ac ? ms max. 12 auxiliary?contacts positive operating contacts to en 60947-5-1 appendix l, including auxiliary contact module ? ? yes rated impulse withstand voltage u imp v ac 6000 overvoltage category/pollution degree ? ? iii/3 rated insulation voltage u i v ac 690 rated operational voltage u e v ac 600 safe isolation to en 61140 ? ? ? between coil and auxiliary contacts ? v ac 300 between the auxiliary contacts ? v ac 300 rated operational current ? ? ? ac-15 ? ? ? 220 v 240 v i e a 6 380 v 415 v i e a 3 500 v i e a 1.5 dc l/r 15 ms ? ? ? contacts in series: ? a ? 1 24 v a 2.5 02/13/2015 012701 - hpl-ed2014 v9.0 en 5 / 12 2 60 v a 2.5 3 100 v a 1.5 3 220 v a 0.5 conv. thermal current i th a 10 control circuit reliability failure rate <10 -8 , < one failure at 100 million operations (at u e = 24 v dc, u min = 17 v, i min = 5.4 ma) component lifespan at u e = 240 v ? ? ? ac-15 operations x 10 6 0.2 dc current ? ? ? l/r = 50 ms: 2 contacts in series at i e = 0.5 a operations x 10 6 0.15 notes ? ? switch-on and switch-off conditions based on dc-13, time constant as specified short-circuit rating without welding ? ? ? maximum overcurrent protective device ? ? ? short-circuit protection only ? ? pkzm0-4 short-circuit protection maximum fuse ? ? ? 500 v ? a gg/gl 6 500 v ? a fast 10 current heat loss at a load of i th per contact ? w 0.3 data?for?design?verification?according?to?iec/en?61439 technical data for design verification ? ? ? rated operational current for specified heat dissipation i n a 22 heat dissipation per pole, current-dependent p vid w 0.68 equipment heat dissipation, current-dependent p vid w 0 static heat dissipation, non-current-dependent p vs w 2.6 heat dissipation capacity p diss w 0 iec/en 61439 design verification ? ? ? 10.2 strength of materials and parts ? ? ? 10.2.2 corrosion resistance ? ? meets the product standard's requirements. 10.2.3.1 verification of thermal stability of enclosures ? ? meets the product standard's requirements. 10.2.3.2 verification of resistance of insulating materials to normal heat ? ? meets the product standard's requirements. 10.2.3.3 verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects ? ? meets the product standard's requirements. 10.2.4 resistance to ultra-violet (uv) radiation ? ? meets the product standard's requirements. 10.2.5 lifting ? ? does not apply, since the entire switchgear needs to be evaluated. 10.2.6 mechanical impact ? ? does not apply, since the entire switchgear needs to be evaluated. 10.2.7 inscriptions ? ? meets the product standard's requirements. 10.3 degree of protection of assemblies ? ? does not apply, since the entire switchgear needs to be evaluated. 10.4 clearances and creepage distances ? ? meets the product standard's requirements. 10.5 protection against electric shock ? ? does not apply, since the entire switchgear needs to be evaluated. 10.6 incorporation of switching devices and components ? ? does not apply, since the entire switchgear needs to be evaluated. 10.7 internal electrical circuits and connections ? ? is the panel builder's responsibility. 10.8 connections for external conductors ? ? is the panel builder's responsibility. 10.9 insulation properties ? ? ? 10.9.2 power-frequency electric strength ? ? is the panel builder's responsibility. 10.9.3 impulse withstand voltage ? ? is the panel builder's responsibility. 10.9.4 testing of enclosures made of insulating material ? ? is the panel builder's responsibility. 10.10 temperature rise ? ? the panel builder is responsible for the temperature rise calculation. eaton will provide heat dissipation data for the devices. 10.11 short-circuit rating ? ? is the panel builder's responsibility. the specifications for the switchgear must be observed. 10.12 electromagnetic compatibility ? ? is the panel builder's responsibility. the specifications for the switchgear must be observed. 10.13 mechanical function ? ? the device meets the requirements, provided the information in the instruction leaflet (il) is observed. 02/13/2015 012701 - hpl-ed2014 v9.0 en 6 / 12 technical?data?etim?5.0 low-voltage industrial components (eg000017) / magnet contactor, ac-switching (ec000066) electric engineering, automation, process control engineering / low-voltage switch technology / contactor (lv) / power contactor, ac switching (ecl@ss8-27-37-10-03 [aab718011]) rated control supply voltage us at ac 50hz ? v 0 - 0 rated control supply voltage us at ac 60hz ? v 0 - 0 rated control supply voltage us at dc ? v 24 - 24 voltage type for actuating ? ? dc rated operation current ie at ac-1, 400 v ? a 22 rated operation current ie at ac-3, 400 v ? a 9 rated operation power at ac-3, 400 v ? kw 4 rated operation current ie at ac-4, 400 v ? a 6.6 rated operation power ie at ac-4, 400 v ? kw 3 modular version ? ? no number of auxiliary contacts as normally open contact ? ? 0 number of auxiliary contacts as normally closed contact ? ? 0 connection type main current circuit ? ? screw connection number of normally closed contacts as main contact ? ? 0 number of main contacts as normally open contact ? ? 4 approvals product standards ? ? iec/en 60947-4-1; ul 508; csa-c22.2 no. 14-05; ce marking ul file no. ? ? e29096 ul category control no. ? ? nldx csa file no. ? ? 012528 csa class no. ? ? 3211-04 north america certification ? ? ul listed, csa certified specially designed for north america ? ? no 02/13/2015 012701 - hpl-ed2014 v9.0 en 7 / 12 characteristics 1: overload relay 2: suppressor 3: auxiliary contact modules enclosure totally insulated 02/13/2015 012701 - hpl-ed2014 v9.0 en 8 / 12 squirrel-cage motor operating characteristics starting:from rest stopping:after attaining full running speed electrical characteristics make: up to 6 x rated motor current break: up to 1 x rated motor current utilization category 100 % ac-3 typical applications compressors lifts mixers pumps escalators agitators fans conveyor belts centrifuges hinged flaps bucket-elevators air conditioning system general drives in manufacturing and processing machines 02/13/2015 012701 - hpl-ed2014 v9.0 en 9 / 12 extreme switching duty squirrel-cage motor operating characteristics inching, plugging, reversing electrical characteristics make: up to 6 x rated motor current break: up to 6 x rated motor current utilization category 100 % ac-4 typical applications printing presses wire-drawing machines centrifuges special drives for manufacturing and processing machines 02/13/2015 012701 - hpl-ed2014 v9.0 en 10 / 12 switching duty for non-motor loads, 3-pole, 4-pole operating characteristics non-inductive or slightly inductive loads electrical characteristics make: 1 x rated current break: 1 x rated current utilization category 100 % ac-1 typical applications electric heat 02/13/2015 012701 - hpl-ed2014 v9.0 en 11 / 12 short-time loading, 3-pole time interval between two loading cycles: 15 minutes dimensions 02/13/2015 eaton industries gmbh http://www.eaton.eu ? 12/2014 by eaton industries gmbh 012701 - hpl-ed2014 v9.0 en 12 / 12 2dile- + mvdile + dile 2dile--g + mvdile + dile additional?product?information?(links) il03407009z?(awa2100-0882)?mini?contactor?relay il03407009z (awa2100-0882) mini contactor relay ftp://ftp.moeller.net/documentation/awa_instructions/il03407009z2010_10.pdf ul/csa: approved rating data http://de.ecat.moeller.net/flip-cat/?edition=hplte&startpage=5.84 |
Price & Availability of DILEM4-G
![]() |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |