  page 1 of 3 ac/dc power supplies tiw series, 4 C 24 watt features high effciency switching power supplies easy installation into standard fush boxes fully encapsulated plastic housing dust and waterproof to ip 67 protection class ll safety approval to iec/en 60950-1 en 50178, en 60335-1, ul 1310 class 2 universal input range 93 to 264 vac regulated output voltage (models from 3.3 to 24 vdc) operating temp. range C25c to +50c short circuit and overload protection 3-year product warranty the tiw series is a new range of small size dc-power supplies which have been designed particularly for applications in home and offce installations. the compact modules cases ft in the standardized in-wall fush boxes or also can be mounted on walls. for connection there are models available with fying wires the power supplies comply fully with the safety and emc standards requested for commercial and residential class ll installations. typical applications are powering of electric devices used in home automation and in security systems like i.e. dc-motors, controllers, indicators, etc. order code output power max. output voltage output current effciency tiw 06-103 4 w 3.3 vdc 1.2 a 75 % tiw 06-105 5 w 5.0 vdc 1.0 a 75 % tiw 06-106 6 w 6.0 vdc 1.0 a 80 % tiw 12-112 12 w* 12 vdc 1.0 a 80 % tiw 12-115 12 w* 15 vdc 0.8 a 80 % tiw 12-124 12 w* 24 vdc 0.5 a 80 % tiw 24-112 24 w* 12 vdc 2.0 a 83 % tiw 24-124 24 w* 24 vdc 1.0 a 85 % models (mounted in standard fush box) cb scheme * if these models are used with 115 vac input voltage, a 25% load reduction must be applied. http://www.tracopower.com
page 2 of 3 ac/dc power supplies tiw series 4 C 24 watt input specifications input voltage range C nominal 115 C 230 vac C ranges 93 C 264 vac (universal input) C output power derating for 12 & 24 w models 0.45 %/v below 187 vac down to 132 vac 1 %/v below 115 vac input frequency 47 C 63 hz no load power consumption (acc. erp directive ec no.278/2009) < 300 mw external input fuse required (recommended values) 2.0 a slow blow harmonic limits en 61000-3-2, class a output specifications voltage set accuracy 3 % max. regulation C input variation 1 % max. C load variation (0C100%) 2 % max. ripple and noise (20 mhz bandwidth) <200 mvp-p overload protection by current limit tiw 06-xxx & tiw 24-xxx models: <2.5 a tiw 12-xxx models: <3.5 a short circuit protection foldback (automatic recovery) general specifications operating temperature C25c to +50c over temperature protection built in reliability, calculated mtbf according to iec 61709 www.tracopower.com/products/tiw-mtbf.pdf humidity (non condensing) 5 C 95 % rel. h max. hold-up time C vin = 115 vac 5 ms typ. C vin = 230 vac 20 ms typ. start-up time <1s safety standards C safety of information technology equipment iec/en 60950-1, ul std. 60950-1 (2nd edition) +am1:2011, can/csa-c22.2 no. 60950- 1- 0 7 + a m1: 2 011 C standard for class 2 power units ul 1310 (6th edition), can/csa-c22.2 no. 223-m91(r2008) outputs C electronic equipment for use in power installations en 5 0178 C safety of household and similar electrical appliances en 60335-1 safety approvals C cb report according iec/en 60950-1 www.tracopower.com/products/tiw-cb.pdf C gs certification (for other standards) www.tracopower.com/products/tiw-gs.pdf C bg certificate www.tracopower.com/products/tiw-bg.pdf C csa certificate www.tracopower.com/products/tiw-csa.pdf electromagnetic compatibility (emc), emissions en 61000-6-3 C conducted ri suppression on input en 55022 class b C radiated ri suppression en 55022 class b electromagnetic compatibility (emc), immunity en 61000-6-2-1, iec 61204-3 C electrostatic discharge (esd) en 61000-4-2 4 kv / 8 kv C radiated rf field immunity en 61000-4-3 3 v/m C electrical fast transient / burst immunity en 61000-4-4 1 kv / 0.5 kv C surge immunity line C ground en 61000-4-5 2 kv C surge immunity line C line en 61000-4-5 1 kv C surge immunity output en 61000-4-5 0.5 kv C immunity to conducted rf disturbances en 61000-4-6 3 v C mains voltage dips and interruptions en 61000-4-11 30 % /10 ms, 60 % /100 ms http://www.tracopower.com all specifcations valid at nominal input voltage, full load and +25c after warm-up time unless otherwise stated.
page 3 of 3 sp ec i?cati ons can be changed wi thout noti ce! make sure you are using the latest documentation, downloadable at www.tracopower. com www .tracopower. com rev. december 09. 2013 general specifications protection class class ii as per iec/en 61140 casing material plastic (ul 94v-0 rated) casing protection ip 67 environment C vibration acc. iec 60068--2-6 part 2, test fe: vibration (sinusoidal) C shock acc. iec 60068-2-27 part 2, test ea: shock connection wires C input 2 x 570 mm +30/-0 (black/white) awg 18 C output 2 x 200 mm +20/-0 (red/black) awg 20 environmental compliance C reach www.tracopower.com/products/tiw-reach.pdf C rohs rohs directive 2011/65/eu weight C 24 watt models: 100 g (3.8 oz) C other models: 80 g (2.7 oz) outline dimensions ac/dc power supplies tiw series 4 C 24 watt + 20 aw g/ re d fl at 2- core ca bl e 16 -1 8a wg . ou te r in su la ti on 3. 5mm x 7. 0m m ty p. 20 aw g/ bl ac k - nl 5. 7 ?8 . 1 ?8 . 1 5. 0 2 input outp ut t op side side view bott m vi ew tole ranc es : 0 .2 mm 8m m 52 .0 4. 0 4. 0 23.6 3. 2 20.5 20.5 12.5 12.5 3. 2 5 5 . 0 r 2 7 . 5 48. 0 5 70m m (+30/-0) 20 0m m 40mm (+20/-0) + 20 aw g/ re d fl at 2- co re ca ble 16 -1 8a wg . ou te r in su lati on 3.5m m x 7. 0m m ty p. 20 aw g/ bl ac k - nl 5. 7 ?8 . 1 ?8 . 1 5. 0 2 input output top side side view bott m vi ew to lera nc es: 0 .2 mm 8m m 52.0 4. 5 4. 5 32 .0 3. 2 23.5 23.5 15 .4 15 .4 3. 2 6 3 . 0 r 3 1 . 5 56 .0 600m m 200m m tiw 6 & 12 watt models: tiw 24 watt model:


▲Up To Search▲   

 
Price & Availability of TIW12-115

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X