. low cost, high reliability . compact size, light weight .105 o c output capacitor . 100% full load burn - in test . international ac input range . high efficiency, low working temperature . soft - start circuit, limiting ac surge current . short circuit, overload, over voltage protected model specification t - 60a t - 60b t - 60c ch1 ch2 ch3 ch1 ch2 ch3 ch1 ch2 ch3 dc output voltage 5v 12v - 5v 5v 12v - 12v 5v 15v - 15v output v. tolerance 2% 6% 6% 2% 6% 6% 2% 6% 6% output rated current 5a 2.5a 0.5a 5a 2.5a 0.5a 5a 2a 0.5a output current range 0.5 - 7a 0.2 - 3.5a 0 - 1a 0.5 - 7a 0.2 - 3.5a 0 - 1a 0.5 - 7a 0.2 - 3a 0 - 1a ripple & noise(vp - p) 100m 100m 100m 100m 100m 100m 100m 100m 100m line regulation 0.5% 1% 0.5% 0.5% 1% 0.5% 0.5% 1% 0.5% load regulation 1% 4% 1% 1% 4% 1% 1% 4% 1% rated output power 57.5w 61w 62.5w efficiency 72% 72% 72% dc voltage adj. ch1:+10, - 5% ch1:+10, - 5% ch1:+10, - 5% input voltage range 85~264vac 47~63hz ; 120~370vdc ac current 2a/115v 1a/230v inrush current cold start 30a/115v 60a/230v leakage current <1ma/240vac overload protection 105%~150%/115vac type:pulsing hiccup shutdown reset:auto recovery over voltage protection ch1:5.75~6.75v temp. coefficient 0.03% / o c (0~50 o c) on +5v output setup,rise,hold up time 800ms, 50ms, 10ms / 115vac 300ms, 50ms, 80ms / 230vac vibration 10~500hz, 2g 3axes 10min. / 1cycle ( 1 hour / each axes ) withstand voltage i/p - o/p:3kvac i/p - fg:1.5kvac o/p - fg:0.5kvac 1min. isolation resistance i/p - o/p,i/p - fg,o/p - fg:500vdc / 100m ohms working temp., humidity - 10 o c~+60 o c(refer to output derating curve), 20%~90% rh storage temp., humidity - 20 o c~+85 o c, 10%~95% rh dimension 159*97*38mm case:901 weight 0.56kgs safety standards ul1012, tuv en60950, iec950, ul1950 approved emc standards cispr22(en55022) class b, iec801 - 2,3,4, iec555 - 2 verification note : 1.all parameters are specified at 230vac input, rated load, 25 o c 70% rh. ambient. 2.tolerance g include set up tolerance, line regulation, load regulation. 3.ripple & noise are measured at 20mhz by using a 12" twisted pair terminated with a 0.1uf & 47uf capacitor. 4.line regulation is measured from low line to high line at rated load. 5.load regulation is measured from 20% to 100% rated load, and other output at 60% rated load 6.each output provide up to maximum current, but total load can not exceed max. output power. 7.c23,6 must be removed.
|