the abc450 series of open - frame power supplies, with its wide universal 90 - 264 vac input range and high power density, is available at 450 w of output power and a variety of single and multiple output voltages. the high efficiency and high power density of the abc family ensures minimal power loss in end - use equipment, thereby facilitating higher reliability, easier thermal management and meets regulatory approvals for environmentally - friendly end products. these medical power supplies are ideal for m onitoring, home health equipment as well as surgical devices. ? 4 x 6.5 x 1.61 inches ? universal ac input ? 450 w (with airflow), 300 w (without airflow) ? current sharing option ? cover and fan options ? peak power capability ? low standby power ? side fan or top fan mounting option product ? ( C s or C t to be added to model number) ? current sharing option p roduct ( C i to be added to model number) ? ite safety agency approvals ? rohs compliant ? ce marked ? instrumentation ? lighting ? industrial applications ? test and measurement ? robotics ? renewable energy ? data communication ? applied computing
2 abc 450 series tech.support@psbel.com model output voltage max load (convection) 1 , 2 , 3 max load (420 lfm) 1,2, 3 minimum load ripple & noise 4 abc 450 - 1t05g 5 vdc 31.0 a 55 .0 a 0.0 a 2% abc 450 - 1t12g 12 vdc 20.83 a 37.5 a 0.0 a 2% abc 450 - 1t15g 15 vdc 16.66 a 30.0 a 0.0 a 2% abc 450 - 1t24g 24 vdc 12.30 a 18.75 a 0.0 a 2% abc 450 - 1t30g 30 vdc 10. 0 a 15 . 0 a 0.0 a 2% abc 450 - 1t48g 48 vdc 6.25 a 9.37 a 0.0 a 2% specifications are for nominal input voltage, 25c unless otherwise stated. parameter description / condition specifications input voltage universal 90 - 264 vac / 120 - 390 vdc input frequency 47 to 63 hz input current 120 vac: 230 vac: 4.5 a max. 2.3 a max. no load power 120 vac: 230 vac: 0.4 w 0.8 w inrush current 120 vac: 230 vac: 40 a max. 75 a max. leakage current earth leakage current touch leakage current 270 a 45 a @120 vac / 63 hz input protection dual fusing, in ac line and ac neutral t8a / 250 v power factor 120 vac 230 vac 0.98 0.95 switching frequency pfc converter: variable resonant converter: variable 45 - 160 khz typical 35 - 250 khz, 90 khz typical 1 combined output power of main output, fan supply and standby supply shall not exceed max. power rating 2 standby output voltage 5 v/ 1.5 a (convection) / 2 a (420lfm) with tolerance including set point accuracy, line and load regulation is +/ - 10%. ripple and noise is less than 5%. 3 fan supply output voltage 12 v / 500 ma with tolerance including set point accuracy, line and load regulation is +/ - 30% and needs min. 1% l oad on main output to be within regulation band. ripple and noise is less than 10%. 4 ripple is peak to pe ak with 20 mhz bandwidth and 10 f (tantalum capacitor) in parallel with a 0.1 f capacitor at rated line voltage and load ranges. please contact fact ory/ sales representative for minimum load required for ripple to be within specification. abc 450 series 3 asia - pacific +86 755 298 85888 europe, middle east +353 61 225 977 north america +1 408 785 5200 ? 201 7 bel power solutions & protection bcd.00326 _a g parameter description / condition specifications output power 5 475 w for 24 v, 30 v & 500 w for 48 v model only for 5 seconds max. 155 to 450 w efficiency (full load) 120 vac 24 v, 48 v, 30 v 12 v, 15 v 5 v 88% 86% 83% typical 230 vac 24 v, 48 v, 30 v 90% hold up time 120 / 230 vac 10 ms line regulation +/ - 0.5% load regulation +/ - 3% transient response <10%, 50% to 100% load change, 50 hz, 50% duty cycle, 0.1 a/ s recovery time < 5 ms rise time < 100 ms set point tolerance +/ - 1% voltage adjustment v1 3 % over voltage protection latch type >114% over current protection hic - up type 120 to 150% short circuit protection short term, auto recovery over temperature protection automatic recovery 130c primary heat sink current share up to 2 supplies connected in parallel (optional) parameter description / condition power good signal ttl signal goes high after main output is within regulation band, delay is 0.1 to 0.3 s remote sense compensates for 200 mv dro p remote on/off to turn on psu short remote pin to ground conducted emissions en55032 - b, cispr22 - b, fcc part15 - b pass radiated emissions en 55032 a; with external core (king core k5b rc 25x12x15 - m in input cable) pass level b input current harmonics en 61000 - 3 - 2 class d voltage fluctuation and flicker en 61000 - 3 - 3 pass esd immunity en 61000 - 4 - 2 level 3, criterion a radiated field immunity en 61000 - 4 - 3 level 3, criterion a electrical fast transient immunity en 61000 - 4 - 4 level 3, criterion a surge immunity en 61000 - 4 - 5 level 3, criterion a conducted immunity en 61000 - 4 - 6 level 3, criterion a magnetic field immunity en 61000 - 4 - 8 level 3, criterion a voltage dips, interruptions en 61000 - 4 - 11 criterion a & b 5 derate output power linearly to 80% from 90 vac to 80 vac input. 4 abc 450 series tech.support@psbel.com parameter description / condition specifications operating temperature refer to derating curve (figure 1) 0 to +70c storage temperature - 40 to 85 c humidity non condensing 95% hr altitude operating: non - operating: 10,000 ft. 40,000 ft. cooling 5 v model convection: 155 w 420 lfm: 275 w 12 v & 15 v models convection: 250 w 420 lfm: 450 w 24 v, 30 v & 48 v models convection: 300 w 420 lfm: 450 w reliability mtbf according to telcordia - sr332 - issue 3 1.28 million hours parameter description / condition specification isolation voltage input to output input to earth 4242 vdc 2121 vdc safety standards approved to the latest edition of the following standards: csa/ul60950 - 1, en60950 - 1 and iec60950 - 1; class1 selv agency approvals nemko, nemko - ccl ce mark complies with lvd directive connector pin description / condition manufacturer / pn ac input connector j1 pin 1 pin 3 pin 5 ac line ac neutral earth tyco: 1 - 1123724 - 3 mating: 1 - 1123722 - 5 dc output connector j2 lug 1 lug 2 +v1 rtn 6 - 32 inches screw pan hd mating: 16 awg wire crimped to ring tongue terminal amp: 8 - 31886 - 1 signals 6 j3 pin 1 pin 2 pin 3 pin 4 pin 5 pin 6 pin 7 pin 8 pin 9 pin 10 nc power fail power good dc return +5vstby +ve remote sense - ve remote sense cs dc return remote on/off molex: 22 - 23 - 2081 mating: 22 - 01 - 2087; pins: 08 - 50 - 0113 fan j4 pin 1 pin 2 +ve - ve mating connector: molex 22 - 01 - 2025 pins = 08 - 50 - 0113 earth 7 j5 molex: 19705 - 4301 mating: 190030001 6 psu is supplied with j3, pin - 9 and pin - 10 shorted to enable main output without remote on/off fe ature 7 the j5 (earth) spade connector can be used for u - channel option products only. when fan options are required the earth connection provided in the input ac connector should be used (pin 5 C j1) abc 450 series 5 asia - pacific +86 755 298 85888 europe, middle east +353 61 225 977 north america +1 408 785 5200 ? 201 7 bel power solutions & protection bcd.00326 _a g convection load: 155 w up to 40 c de - rate above 40 c @ 1.67% per c forced air cooled load: 275 w up to 40c de - rate above 40 c @ 1.67% per c convection load: 250 w up to 40 c de - rate above 40 c @ 1.67% per c forced air cooled load: 450 w up to 40c de - rate above 40 c @ 1.67% per c convection load: 300 w up to 50 c de - rate above 50 c @ 2.5% per c forced air cooled load: 450 w up to 50c de - rate above 50 c @ 2.5% per c figure 1. derating curves 6 abc 450 series tech.support@psbel.com parameter description / condition weight 900 g (1.98 lbs) dimensions 101.6 x 165.0 x 41.0 mm (4.0 x 6.5 x 1.6 inch) figure 2. mechanical drawing (without fan mounting) abc 450 series 7 asia - pacific +86 755 298 85888 europe, middle east +353 61 225 977 north america +1 408 785 5200 ? 201 7 bel power solutions & protection bcd.00326 _a g figure 3 - mechanical drawing (with top fan mounting) 8 abc 450 series tech.support@psbel.com figure 4 - mechanical drawing (with side fan mounting) abc 450 series 9 asia - pacific +86 755 298 85888 europe, middle east +353 61 225 977 north america +1 408 785 5200 ? 201 7 bel power solutions & protection bcd.00326 _a g during the installation and setup of parallel supplies in a system it is important that a single remote sense point be used f or all the supplies. the remote sense voltage between the supplies must be adjusted to within 2% to ensure the supplies are inside the 3% capture window. if the supplies are not initially adjusted inside the capture window the supplies will not current share. note: current sharing facility is inclusive with the unit only with ordering of the current sharing option unit i.e. abc450 - 1xxx - i or abc 450 - 1xxx - i. set - up procedure: 1 connect load cables to the outputs of each supply. 2 connect the remote sense lines to the load in twisted style. (a common remote sense point must be used for all the supplies in parallel). 3 connect all the current share pins on the j3 connector between the supplies. 4 adjust remote sense voltage of each supply to within 1% of rated output volt age or readjust to required set point. (adjustment to be done with all other parallel supplies off). 5 current sharing between the supplies can be verified by monitoring the output current of each supply with a hall effect dc current probe. the supplies shou ld share to within 10% of the total load current. 6 the current share circuit has a capture window voltage of +/ - 3% of the rated output voltage. if the output remote sense voltage of one of the supplies is adjusted outside the 3% window the supplies will no t current share. nuclear and medical applications - products are not designed or intended for use as critical components in life support systems, equipment used in hazardous environments, or nuclear control systems. technical revisions - the appearance of products, including safety agency certifications pictured on labels, may change depending on the date manufactured. specifications are subject to change without notice. |
Price & Availability of ABC450-1T24G
![]() |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |