model pba600f-3r3 pba600f-5 pba600f-7r5 pba600f-12 PBA600F-15 pba600f-24 pba600f-36 pba600f-48 max output wattage[w] 396 600 600 636 645 648 648 624 dc output acin 100v 3.3v 120a 5v 120a 7.5v 80a 12v 53a 15v 43a 24v 27a 36v 18a 48v 13a acin 200v * 3 3.3v 120a 5v 120a 7.5v 80a 12v 53a 15v 43a 24v 27 ( 31 ) a 36v 18a 48v 13a specifications model pba600f-3r3 pba600f-5 pba600f-7r5 pba600f-12 PBA600F-15 pba600f-24 pba600f-36 pba600f-48 input voltage[v] ac85 - 264 1 f or dc120 - 350 current[a] acin 100v 5.8typ 8.2typ acin 200v 3typ 4.1typ frequency[hz] 50/60 ( 47-63 ) efficiency[%] acin 100v 70typ 75typ 76typ 79typ 79typ 81typ 82typ 81typ acin 200v 72typ 77typ 79typ 82typ 82typ 84typ 84typ 83typ power factor acin 100v 0.98typ ( io=100% ) acin 200v 0.95typ ( io=100% ) inrush current[a] acin 100v 20/40typ ( io=100% )( primary inrush current /secondary inrush current )( more than 3 sec. to re-start ) acin 200v 40/40typ ( io=100% )( primary inrush current /secondary inrush current )( more than 3 sec. to re-start ) leakage current[ma] 0.45/0.75max ( acin 100v/240v 60hz , io=100% , according to iec60950-1 ) output voltage[v] 3.3 5 7.5 12 15 24 36 48 current[a] acin 100v 120 120 80 53 43 27 18 13 acin 200v * 3 120 120 80 53 43 27 ( 31 ) 18 13 line regulation[mv] 20max 20max 36max 48max 60max 96max 144max 192max load regulation[mv] 40max 40max 60max 100max 120max 150max 150max 300max ripple[mvp-p] 0to+50 c * 1 80max 80max 120max 120max 120max 120max 150max 150max -20-0 c * 1 140max 140max 160max 160max 160max 160max 160max 400max ripple noise[mvp-p] 0to+50 c * 1 120max 120max 150max 150max 150max 150max 200max 200max -20-0 c * 1 160max 160max 180max 180max 180max 180max 240max 500max temperature regulation[mv] 0to+50 c * 1 40max 50max 75max 120max 150max 240max 360max 480max -20 to +50 c * 1 60max 75max 120max 180max 180max 290max 440max 600max drift[mv] * 2 * 4 12max 20max 30max 48max 60max 96max 144max 192max start-up time[ms] 400typ ( acin 100/200v , io=100% ) start-up time is 500ms typ for less than 1minute of applying input again from turning off the input voltage. hold-up time[ms] 20typ ( acin 100/200v , io=100% ) output voltage adjustment range[v] 2.64 - 3.96 3.96 - 6.00 5.25 - 8.25 8.25 - 13.20 10.50 - 16.50 16.50 - 26.40 25.20 - 39.60 38.40 - 56.00 output voltage setting[v] 3.30 - 3.40 5.00 - 5.15 7.50 - 7.80 12.00 - 12.48 15.00 - 15.60 24.00 - 24.96 36.00 - 37.44 48.00 - 49.92 protection circuit and others overcurrent protection works over 105% of rated current or 101% of peak current and recovers automatically overvoltage protection[v] vo+0.66 - 1.32 vo+1.0 - 2.0 vo+1.5 - 3.0 vo+2.4 - 4.8 vo+3.0 - 6.0 vo+4.8 - 9.6 vo+7.2 - 14.4 vo+4.8 - 12.0 operating indication led ( green ) remote sensing provided remote on/off provided isolation input-output - rc ac3 , 000v 1minute , cutoff current = 10ma , dc500v 50m w min ( at room temperature ) input-fg ac2 , 000v 1minute , cutoff current = 10ma , dc500v 50m w min ( at room temperature ) output - rc - aux-fg ac500v 1minute , cutoff current = 100ma , dc500v 50m w min ( at room temperature ) output-rc - aux ac100v 1minute , cutoff current = 100ma , dc100v 50m w min ( at room temperature ) environment operating temp. , humid.and altitude -20 to +71 c , 20 - 90%rh ( non condensing ) 3 , 000m ( 10 , 000feet ) max storage temp. , humid.and altitude -20 to +75 c , 20 - 90%rh ( non condensing ) 3 , 000m ( 10 , 000feet ) max vibration 19.6m/s 2 ( 2g ), 10 - 55hz , 3minutes period , 60minutes each along x , y and z axis impact 196.1m/s 2 ( 20g ), 11ms , once each x , y and z axis safety and noise regulations agency approvals ul60950-1 , c-ul ( csa60950-1 ), en60950-1 , en50178 complies with den-an ( at only ac input ) conducted noise complies with fcc part15 classb , vcci-b , cispr22-b , en55011-b , en55022-b ce marking low voltage directive , emc directive harmonic attenuator complies with iec61000-3-2 others case size/weight 120 x 61 x 190mm ( without terminal block and screw )( w x h x d ) /1.6kg max cooling method forced cooling ( internal fan ) * 1 measured by 20mhz oscilloscope or ripple-noise meter(equivalent to keisoku-giken : rm101). * 2 drift is the change in dc output for an eight hour period after a half-hour warm-up at 25 c . * 3 () means peak current. peak loading for 10s. and duty 35% max, refer to instruction manual in detail. * 4 overvoltage protection circuit to follow to output voltage setting. * a sound may occur from power supply at pulse loading. pba600f unit type pba 600 f -5 - o ordering information 1 series name 2 output wattage 3 universal input 4 output voltage 5 optional c :with coating g :low leakage current u :operation stop voltage is set at a lower value f1 :with long-life fan f3 :reverse air exhaust type f4 :low speed fan r 12345 pba a-14 refer to instruction manual 7.1
|