ld e160 - 26 is a wide range din rail switching power supply with output power up to 160 w offering unmatched flexibility for many applications. its compact size, high efficiency, excellent reliability together with easy installation due to pluggable connectors makes it market leader for various industrial applications. ld e160 - 26 is class i isolation device suitable for selv and pelv circuitry and is designed to be mounted on din rail and installed inside a protective enclosure. ? single or two - phase ac input 187 - 5 28 vac ? latched overload and short - circuit protection ? designed according to en12015 and en12016 for elevators use ? high efficiency ? industrial control ? instrumentation equipment
2 lde160 - 26 tech.support@psbel.com lde160 - 26 380 vac ( range 187 - 5 28 va c) 26 v dc (fixed) 6.0 a specifications are measured at 25c and 230 vac , typical unless otherwise stated. input ac voltage nominal C single or two phases range 380 vac 187 - 5 28 vac input frequency 47 - 63 hz input ac rated current vin = 187 vac vin = 380 vac vin = 528 vac 1.8 a 1.0 a 0.8 a inrush peak current 30 a touch (leakage) c urrent 0.8 ma internal protection f use none, external fuse must be provided external protection on ac line it is strongly recommended to provide external surge arresters (spd) according to local regulations. fuse 4at or mcb 6a c curve output power 16 0 w output voltage 26 vdc (fixed) continuous current 6 a overload limit l atched protection up to 10 a / 5 s short circuit peak current 2 5 a load regulation 1% ripple & noise 1 15 0 mvpp hold up time v in = 230 vac v in = 480 vac 20 ms 110 ms output overvoltage protection 33 vdc protections overload and overvoltage latched off thermal protection output overvoltage status signals g reen led - dc ok r ed led - alarm parallel connection possible for redundancy (with external oring module) efficiency > 88 % dissipated power < 25 w 1 ripple and noise are measured with 20 mhz bandwidth, probe terminated with a 0.1 f mkp parallel capacitor.
lde160 - 26 3 asia - pacific +86 755 298 85888 europe, middle east +353 61 225 977 north america +1 408 785 5200 ? 2017 bel power solutions & protection bcd.00850 _ aa operating temperature 2 - 40 c to + 5 0c storage temperature - 40 c to + 8 0c d erating - 15 w/oc over 4 5oc humidity non - condensing 5 C 95% rh life time expectancy a t 25c ambient , full load 77 726 h (8.8 years) overvoltage category pollution degree en50178 iec60664 - 1 ii i 2 safety standards & approvals ul508 (reference) en60950 (reference) en50178 (reference) emc standards emission: en55011 (cispr11) en55022 (cispr22) en12015 class a class a class a immunity: en61000 - 4 - 2 en61000 - 4 - 3 en61000 - 4 - 4 en61000 - 4 - 5 en61000 - 4 - 11 en12016 level 3 level 3 level 3 level 3 level 2 isolation voltage input to output input to ground output to ground 4.2 kv d c 2.2 kvdc 0.7 5 kvdc protection degree en60529 ip20 vibration sinusoidal iec 60068 - 2 - 6 (5 - 17.8hz: 1.6mm; 17.8 - 500hz: 2g 2hours / axis (x,y,z) shock iec 60068 - 2 - 27 (30g 6ms, 20g 11ms; 3 bumps / direction, 18 bumps total) weight 0.5 k g dimensions (w x h x d) 108.5 x 110.0 x 74.5 mm connection terminals screw type (24 - 12 awg) 2.5 mm2 case material aluminum iec 60715/h15/th35 - 7.5( - 15) mounting rail rail m ounting i nformation vertical, allow 10mm spacing between adjacent items notes: technical parameters are typical, measured in laboratory environment at 25 oc and 400 vac / 50 hz. power rating, losses, efficiency, ripple, thermal behaviour and start - up may change outside of the nominal rated input range. contact factory for details. 2 start - up type tested: - 40c, possible at nominal voltage with load derating.
4 lde160 - 26 tech.support@psbel.com figure 1 . mechanical dr awing input connection o utput connection single phase: l1 = line n = neutral i = earth ground + = positive dc - = negative dc two phases: l1 = phase 1 l2 = phase 2 i = earth ground nuclear and medical applications - products are not designed or intended for use as critical components in life support systems, equipment used in hazardous environments, or nuclear control systems. technical revisions - the appearance of products, including safety agency certifications pictured on labels, may change depending on the date manufactured. specifications are subject to change without notice.
|