? 2015 bel power solutions, inc. north america +1 - 866.513.2839 asia - pacific +86.755.29885888 europe, middle east +353 61 225 977 tech.support@psbel.com bcd.0066 7 _ 00 1 ? 3 x 2 footprint ? 120 watts with forced air cooling ? approval to en60601 3 rd edition ? efficiencies up to 93% ? - 40 to 70 degree operating temperature ? dual fusing ? thermal shut - down feature ? >3.00 million hours, telcordia - sr332 - i ssue 3 ? standby power < 0.3w ? class ii option a vailable ? rohs compliant ? ce m arked the mbc 120 series of open frame medical power supplies feature a wide universal ac input range of 85 v C 264 vac, offering 120 w of output p ower in a compact footprint, with a variety of isolated single output voltages. the mbc series was designed to 3 rd edition medical approvals and provides 2x mopp (means of patient protection) isolation for class i and class ii installations. these power supplies are ideal for medical, telecom, datacom, industrial equipment and other applications. ? diagn ostic ? drug pump ? dialysis ? home health care ? monitoring ? portable equipment
m bc 120 series ? 2015 bel power solutions, inc. 866.513.2839 tech.support@psbel.com bcd.00667 _ 00 1 model number 2 description voltage max. load (convection) max. load (200 lfm) min. load ripple & noise 1 mbc 120 - 1t12l mbc120 - 1012l screw terminal molex header 12 v 8.33 a 10.0 a 0.0 a 1% mbc120 - 1t15l mbc120 - 1015l screw terminal molex header 15 v 6.66 a 8.0 a 0.0 a 1% mbc120 - 1t24l mbc120 - 1024l screw terminal molex header 24 v 4.16 a 5.0 a 0.0 a 1% mbc120 - 1t30l mbc120 - 1030l screw terminal molex header 30 v 3.33 a 4.0 a 0.0 a 1% mbc120 - 1t48l mbc120 - 1048l screw terminal molex header 48 v 2.08 a 2.5 a 0.0 a 1% mbc120 - 1t58l mbc120 - 1058l screw terminal molex header 58 v 1. 72 a 2.07 a 0.0 a 1% cover - 120 - xbc metal cover kit accessory 1 ripple is peak to peak with 20 mhz bandwidth and 10 f (tantalum capacitor) in parallel with a 0.1 f capacitor at rated line voltage and load ranges. 2 for class i i option ( without input earth pin ) add suffix: - 2 (e.g.: mbc120 - 1012l - 2) .
m bc 120 series ? 2015 bel power solutions, inc. 866.513.2839 tech.support@psbel.com bcd.00667 _ 00 1 specifications are for nominal input voltage, 25c unless otherwise stated. parameter description / condition specification input voltage universal (see derating under output power) 85 - 264 vac / 390 vdc 3 input frequency 47 - 63 hz input current 115 vac: 230 vac: 1.2 a max. 0. 6 5 a max. no load power typical < 0.3 w inrush current 115 vac: 230 vac: 264 vac: 25 a 45 a 75 a leakage current typical (n.a. for class ii option) touch current 300 ua <100 ua power factor @ full load > 0.95 switching frequency typical 6 0 khz 3 functional, not approved. parameter description / condition specification output power with 200 lfm: convection: 120 w up to 100 w efficiency 48 v , 58 v : 24 v, 30 v: 12 v, 15 v: 93% 91% 90% hold - up time typical > 1 0 ms line regulation +/ - 0.5% load regulation +/ - 1 % transient response 25% step load change, at 0.1a/us slew rate, 50% duty cycle, 50 hz = 4% recovery time < 5 ms voltage adjustment +/ - 3 % rise time typical 55 ms set point tolerance +/ - 1% over current protection > 110% over voltage protection latch type (ac recycling required) 110 to 140% short circuit protection hiccup mode parameter description / condition specification operating temperature startup guaranteed, derate linearly above 50 c to 70 c as per f ig 1. - 40 to +70c - 40 to 0c storage temperature - 40 to +85c cooling forced: with 3 00 lfm (refer to mech. drawing) convection: for input 100 - 264 vac (derate linearly to 80w @ 85vac) 120 w 100 w relative humidity noncondensing 5% to 95% altitude operating: nonoperating: 16 ,000 ft 40,000 ft. reliability mtbf according to telcordia - sr332 - i ssue 3 3.00 million hours
m bc 120 series ? 2015 bel power solutions, inc. 866.513.2839 tech.support@psbel.com bcd.00667 _ 00 1 parameter description / condition specification conducted emissions en55022 - b, cispr22 - b, fcc part15 - b static discharge en61000 - 4 - 2: level - 3 rf field susceptibility en61000 - 4 - 3: level - 3 fast transients/bursts en61000 - 4 - 4: level - 3 radiated emissions radiated: radiated with external core: (king core k5b rc 25x12x15 - m in input cable with 5 turns) level a level b surge susceptibility en61000 - 4 - 5: level - 3 harmonic current en61000 - 3 - 2: class d parameter description / condition specification isolation voltage input to output: (for medical applications ) input to gnd: (not applicable for class ii option) output to gnd : for type bf for type b (n/a for class ii option) 4 000 vac 1500 vac 1500 vac 500 vac safety standard(s) approved to the latest edition of the following standards: csa/ul60601 - 1, en60601 - 1 and iec60601 - 1. agency approvals nemko, ul, c - ul ce mark complies with lvd directive figure 1 C derating curve connector pin description / condition manufacturer / pn ac input connector j1 pin 1 pin 2 pin 3 ac line not fitted ac neutral screw terminal (option 1) molex: 39357 - 0003 tyco - 2 - 1776112 - 3 molex header (option 2) molex: 1722861103 (mating conn: molex 1722561003) dc output connector j2 pin 1, 2 pin 3, 4 v1 + ve v1 - ve screw terminal (option 1) molex: 39357 - 0004 tyco - 2 - 1776112 - 4 molex header (option 2) molex: 1722861104 (mating conn: molex 1722561004)
m bc 120 series ? 2015 bel power solutions, inc. 866.513.2839 tech.support@psbel.com bcd.00667 _ 00 1 parameter description / condition weight 150 g dimensions 76.2 x 50.8 x 30.1 mm ( 3 x 2 x 1 .18 inch) figure 2 - mechanical drawing - screw terminal ( option 1 )
m bc 120 series ? 2015 bel power solutions, inc. 866.513.2839 tech.support@psbel.com bcd.00667 _ 00 1 figure 3 - mechanical drawing - molex header ( option 2 ) nuclear and medical applications - products are not designed or intended for use as critical components in life support systems, equipment used in hazardous environments, or nuclear contr ol systems. technical revisions - the appearance of products, including safety agency certifications pictured on labels, may change depending on the date manufactured. specifications are subject to change without notice.
|