Part Number Hot Search : 
2SB772 25ETTS MP23550 2N5859 A680M SZ5234B EPA34 MCM2532
Product Description
Full Text Search
 

To Download SC35VB100 Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
  glass passivated 3 phase bridge rectifiers features surge overload -350 amperes peak low forward voltage drop mounting position :any weight: 45g maximum ratings and electrical characteristics characteristics symbol unit maximum recurrent peak reverse voltage v rrm v maximum rms bridge input voltage v rms v maximum average forward rectified output current @ t c =55 peak forward surge current 8.3ms single half sine-wave super imposed on rated load current squared time (1ms t10ms) i 2 t a 2 s dielectric strength vdis v mounting torque tor n.m maximum forward voltage drop per element at 17.5 a peak maximum reverse current at rated dc blocking voltage per element @ t a =25 typical thermal resistance (note1) r jc /w operating temperature range t j storage temperature range t stg notes: 1.thermal resistance junction to case. 2.the typical data above is for reference only( ?). rev. 2, 16-mar-2017 i (av) 35 SC35VB100 reverse voltage - 1000 volts forward current - 35 amperes dimensions in inches and (milimeters) rating at 25 ambient temperature unless otherwise specified. resistive or inductive load 60hz. for capacitive load, derate current by 20% SC35VB100 1000 700 -55 to +150 a i fsm 350 a 508 2000 v f v i r 10 a max: 0.7 -55 to +150 1.05 0.8 scvb r3.5 .169(4.3) .185(4.7) .402(10.2) .413(10.5) .055(1.4) .063(1.6) (29.0) max .256(6.5) .217(5.5) .386(9.8) .409(10.4) .071(1.8) .039(1.0) .555(14.1) .516(13.1) .516(13.1) .555(14.1) .035(0.9) .028(0.7) .256(6.50) .244(6.20) .374(9.5) .334(8.5) .334(8.5) .374(9.5) .295(7.5) .256(6.5) max (36.0) 1.417 1.417 (36.0) max r1.75 .295(7.5) .256(6.5) .504 (12.8) (12.8) .504 .516 (13.1) .492 (12.5) .146 ( 3.7)*45 .138(3.5) 1.142
rating and characteristic curves SC35VB100 the curve graph is for reference only, can't be the basis for judgment( ?)! rev. 2, 16-mar-2017 instantaneous forward voltage,volts instantaneous forward current ,(a) fig.3-typical forward characteristics 100 10 1.0 0.1 0.01 0.6 0.8 1.0 1.2 1.4 0.4 1.6 10 1.0 0.1 0.01 0 120 20 40 60 80 100 140 t j =25c percent of rated peak reverse voltage instantaneous reverse current, microamperes fig.4-typical reverse characteristics average forward output current , amperes fig.2- derating curve output rectified current case temperature,c 150 100 20 0 10 30 40 50 50 with heatsink number of cycles at 60hz peak forward surge current , amperes fig.1-maxmun forward surge current 200 300 100 10 1 350 400 450 500 150 100 50 250 0 pulse width 8.3ms single half-sine -wave (jedec method)
legal disclaimer notice all specifications and data are subject to be changed without notice to improve reliability function or design or other reasons. hy makes no warranty, representation or guarantee regarding the suitability of the products for any particular purpose or the co- tinuing production of any product. to the maximum extent permitted by applicable law, hy disclaims (i) any and all liability arising out of the application or use of any product, (ii) any and all liability, including without limitation special,consequential or incidental d- amages, and (iii) any and all implied warranties, including warranties of fitness for particular purpose, non-infringement and merch- antability. statements regarding the suitability of products for certain types of applications are based on hy?s knowledge of typical require- ments that are often placed on hy products in generic applications. such statements are not binding statements about the suitabi- lity of products for a particular application. it is the customer?s responsibility to validate that a particular product with the properties described in the product specification is suitable for use in a particular application.parameters provided in datasheets and specific- ations may vary in different applications and performance may vary over time. all operating parameters, including typical paramet- ers, must be validated for each customer application by the customer?s technical experts. product specifications do not expand or otherwise modify hy?s terms and conditions of purchase, including but not limited to the warranty expressed therein. except as expressly indicated in writing, hy products are not designed for use in medical, life-saving, or life-sustaining applicati- ons or for any other applications in which the failure of the hy product could result in personal injury or death. customers using or selling hy products not expressly indicated for use in such applications do so at their own risk.please contact authorized hy pers- onnel to obtain written terms and conditions regarding products designed for such applications. no license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted by this document or by any conduct of hy. product names and markings noted herein may be trademarks of their respective owners. ?????????? hy ???????????hy (i) ? ??????(ii) ???????(iii) ??? ???????? ????? hy ? hy ???????????? ???????????????? ????? ????????????? ??? hy ???? hy ???? ?hy ????? hy ??????? ?????? hy ????????hy ?? ? ? hy ??????????????????? ??? rev. 2, 16-mar-2017 disclaimer


▲Up To Search▲   

 
Price & Availability of SC35VB100

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X