If you can't view the Datasheet, Please click here to try to view without PDF Reader . |
|
Datasheet File OCR Text: |
isolated, regulated dc converter dcm ? in a via package dc-dc converter features & bene?ts ? isolated, regulated dc-to-dc converter ? up to 180 w, 36.00 a continuous ? 90.8% peak efficiency ? 103 w/in 3 power density ? wide input range 16 C 50 vdc ? safety extra low voltage (selv) 5.0 v nominal output ? zvs high frequency switching ? allows remote sense or local sense operation ? tight regulation over all line and load conditions ? fully operational current limit ? ov, oc, uv, short circuit and thermal protection ? available in chassis mount and through hole via package n 3.380 x 1.400 x 0.370 (85.93 mm x 35.5 mm x 9.40 mm) typical applications ? industrial ? process control ? heavy equipment ? defense / aeorspace product description the dcm in a via package is an isolated, regulated dc-to-dc converter, operating from an unregulated, wide range input to generate an isolated 5.0 vdc output. with its high frequency zero voltage switching (zvs) topology, the dcm converter consistently delivers high e?ciency across the input line range. the dcm provides tight output voltage regulation and o?ers a secondary-referenced control interface for trim, enable, and remote sense operation. dcm converters and downstream dc- dc products support e?cient power distribution, providing superior power system performance and connectivity from a variety of unregulated power sources to the point-of-load. the via package o?ers ?exible thermal management options with very low top and bottom side thermal impedances. product ratings v in = 16 v to 50 v p out = 180 w v out = 5.0 v (4.0 v to 5.5 v trim) i out = 36.00 a part ordering information product function package length package width package type max input voltage range ratio max output voltage max output power product grade (case temperature) option field dcm 34 14 x 50 m 06 a8 y z z dcm = dc-dc converter length in inches x 10 width in inches x 10 b = board via v = chassis via internal reference c = -20 to 100c [1] t = -40 to 100c [1] m = -55 to 100c [1][2] 01 = chassis/analog 05 = short pin/analog 09 = long pin/analog size: 3.380 x 1.400 x 0.370 in 85.93 x 35.5 x 9.40 mm [1] high temperature power derating may apply, see thermal speci?ed operating area, figure 1 on page 4. [2] m-grade available on selected models. consult vicorpower.com for details. dcm3414x50m06a8yzz dcm ? in a via package rev 1.3 vicorpower.com page 1 of 22 07/2017 800 927.9474 c us ? s nrtl cu s
typical application +in +out vd de en tr -ense +sense -in out dcm tm in ? a?ackage c out-ext c f v in non-isolated point-of-load regulator load load typical application: single dcm3414x50m06a8yzz in local sense operation, to a non-isolated regulator, and direct to load dcm3414x50m06a8yzz dcm ? in a via package rev 1.3 vicorpower.com page 2 of 22 07/2017 800 927.9474 1 2 4 +in +out top view dcm in a via package - chassis mount 3 Cut Cn 5 vdde 6 en 7 tr 8 Cense 9 +sense 2 1 3 Cn Cut top view dcm in a via package - pcb mount 4 +out +in 9 +sense 8 Cense 7 tr 6 en 5 vdde pin con?guration pin descriptions pin number signal name type function 1 +in input power positive input power terminal 2 Cin input power return negative input power terminal 3 +out output power positive output power terminal 4 Cout output power return negative output power terminal 5 vdde power input external power supply for internal controller 6 en control input enables and disables dcm. needs vdde preapplied 7 tr control input enables and disables trim functionality. adjusts output voltage when trim active. 8 Csense control input negative sense pin, required for remote sense operation. in local sense operation, it can be tied directly to Cout to achieve better regulation accuracy. 9 +sense control input positive sense pin, required for remote sense operation. in local sense operation, it can be tied directly to +out to achieve better regulation accuracy. note: all control inputs (en, tr, Csense, +sense) are referenced to the secondary of the dcm and isolated from the primary. dcm3414x50m06a8yzz dcm ? in a via package rev 1.3 vicorpower.com page 3 of 22 07/2017 800 927.9474 note: the dot on the via housing indicates the location of the control pin 9 (+sense pin). absolute maximum ratings the absolute maximum ratings below are stress ratings only. operation at or beyond these maximum ratings can cause permanent damage to the device. electrical specifications do not apply when operating beyond rated operating conditions. parameter comments min max unit input voltage (+in to Cin) c grade, t grade -0.5 65 v input voltage (+in to Cin)* m grade (continuous absolute maximum input voltage)** -0.5 52 v input voltage slew rate 1 v/s tr to Cout -0.3 3.5 v en to Cout -0.3 3.5 v vdde to Cout 0 12 v Csense to Cout 0 2.225 v +out to +sense 0 2.225 v +sense to Cout 0 6.5 v output voltage (+out to Cout) -0.5 7.2 v dielectric withstand (input to output) 1500 vdc internal operating temperature c grade -20 125 c t grade -40 125 c m grade -55 125 c storage temperature c grade -20 125 c t grade -40 125 c m grade -65 125 c average output current 36.0 a figure 2 electrical specified operating area figure 1 thermal specified operating area: max output power vs. case temp, single unit at minimum full load efficiency dcm3414x50m06a8yzz dcm ? in a via package rev 1.3 vicorpower.com page 4 of 22 07/2017 800 927.9474 * lvmfm + 16 C 50 v input range products guarantees mil-std 461e/f & mil-std 1275 d/e. ** applicable only for 16 C 50 v input range products. electrical speci?cations specifications apply over all line, trim and load conditions, internal temperature t int = 25oc, unless otherwise noted. boldface specifications apply over the temperature range specified by the product grade. attribute symbol conditions / notes min typ max unit power input speci?cation input voltage range v in continuous operation 16 28 50 v inrush current (peak) i inrp with maximum c out-ext , full resistive load 18.0 a input capacitance (internal) c in-int effective value at nominal input voltage 29.7 f input capacitance (internal) esr r cin-int at 1 mhz 0.73 m input inductance (external) l in differential mode, with no further line bypassing 1 h no load speci?cation input power C disabled p q nominal line, see fig. 3 0.5 0.7 w worst case line, see fig. 3 0.9 w input power C enabled with no load p nl nominal line, see fig. 4 2.0 3.2 w worst case line, see fig. 4 4.0 w power output speci?cation output voltage set point v out-nom 4.95 5.0 5.05 v rated output voltage trim range v out-trimming trim range over temp. speci?es the low, nominal and high trim conditions. 4.0 5.0 5.5 v v out accuracy %v out- accuracy total output voltage setpoint accuracy for all line conditions and for all load conditions above 10% of rated load, with trim inactive and sense pins connected (either at the load for remote sense, or at the dcm output for local sense) 1.0 % v out accuracy with sense pins ?oating %v out- accuracy-sf total output voltage setpoint accuracy for all line conditions and for all load conditions above 10% of rated load, with trim inactive and sense pins ?oating (local sense only) 1.0 % v out accuracy with trim active %v out- accuracy-trim total output voltage setpoint accuracy for all line conditions and for all load conditions above 10% of rated load, with trim active 2.0 % v out accuracy light load %v out- accuracy-ll total output voltage setpoint accuracy for all line and trim conditions, for load conditions below or equal to 10% of rated load 5.0 % rated output power p out continuous, v out 5.0 v 180 w rated output current i out continuous, v out 5.0 v 36.00 a output current limit i out-lm of rated i out max. fully operational current limit, for nominal trim and below 100 120 135 % current limit delay t iout-lim the module will power limit in a fast transient event 1 ms ef?ciency full load, nominal line, nominal trim 88.8 90.5 % full load, over line and temperature, nominal trim 86.4 % 50% load, over rated line, temperature and trim 83.5 % output voltage ripple v out-pp over all operating steady-state line, load and trim conditions, 20 mhz bw, with minimum c out-ext 180 mv output capacitance (internal) c out-int effective value at nominal output voltage 349 f output capacitance (internal) esr r cout-int at 1 mhz 0.07 m dcm3414x50m06a8yzz dcm ? in a via package rev 1.3 vicorpower.com page 5 of 22 07/2017 800 927.9474 electrical speci?cations (cont.) specifications apply over all line, trim and load conditions, internal temperature t int = 25oc, unless otherwise noted. boldface specifications apply over the temperature range specified by the product grade. attribute symbol conditions / notes min typ max unit power output speci?cations (cont.) output capacitance (external) c out-ext excludes component temperature coef?cient. for load transients that remain > 10% rated load 1000 20000 f output capacitance (external) c out-ext- transient excludes component temperature coef?cient. for load transients down to 0% rated load 10000 20000 f output capacitance, esr (ext.) r cout-ext at 10 khz, excludes component tolerances 10 m initialization delay t init see state diagram 25 40 ms output turn-on delay t on from rising edge en, with vdde pre-applied. see timing diagram 200 s output turn-off delay t off from falling edge en. see timing diagram 600 s soft start ramp time t ss full load (soft-start ramp time) with minimum c out-ext 125 ms v out threshold for max rated load current v out-fl-thresh during startup, v out must achieve this threshold before output can support full rated current 3.0 v i out at startup i out-start max load current at startup while v out is below v out-fl-thresh 3.60 a monotonic soft-start threshold voltage v out-monotonic output voltage rise becomes monotonic with 1% of preload once it crosses v out-monotonic 4.0 v minimum required disabled duration t off-min this refers to the minimum time a module needs to be in the disabled state before it will attempt to start via en 2 ms minimum required disabled duration for predictable restart t off-monotonic this refers to the minimum time a module needs to be in the disabled state before it is guaranteed to exhibit monotonic soft-start and have predictable startup timing 100 ms voltage deviation (transient) %v out-trans minimum c out_ext (10 ? 90% load step) <10 % settling time t settle 2.0 ms powertrain protections input voltage initialization threshold v in-init threshold to start t init delay 6.0 v input voltage reset threshold v in-reset latching faults will clear once v in falls below v in-reset 3.0 v input undervoltage lockout threshold v in-uvlo- 9.6 15.2 v input undervoltage recovery threshold v in-uvlo+ see timing diagram 16.0 v input overvoltage lockout threshold* v in-ovlo+ 55.0 v input overvoltage recovery threshold* v in-ovlo- see timing diagram 50.0 v output overvoltage threshold v out-ovp latched shutdown 6.9 v minimum current limited v out v out-uvp over all operating steady-state line and trim conditions 2.6 v overtemperature threshold (internal) t int-otp 130.0 c power limit p lim 325.0 w v in overvoltage to cessation of powertrain switching t ovlo-sw independent of fault logic 1.5 s v in overvoltage response time t ovlo for fault logic only 200 s v in undervoltage response time t uvlo 100 ms short circuit response time t sc powertrain on, operational state 200 s short circuit, or temperature fault recovery time t fault see timing diagram 1 s dcm3414x50m06a8yzz dcm ? in a via package rev 1.3 vicorpower.com page 6 of 22 07/2017 800 927.9474 * input ovlo protection speci?cations do not apply for 16 C 50 v input range m grade products. signal speci?cations specifications apply over all line, trim and load conditions, internal temperature t int = 25oc, unless otherwise noted. boldface specifications apply over the temperature range specified by the product grade. please note: for chassis mount models, vicor part number 42550 will be needed for applications requiring the use of signal pins (enable, trim and sense functions). [2] enable: en ? the en pin enables and disables the dcm; when held low the unit will be disabled. ? the en pin is activated only if vdde is preapplied before v in is applied. otherwise, en is inactive and will be ignored until v in is removed and reapplied. additonally, if vdde is removed at any time, en will return to inactive mode. ? the en pin is referred to the Cout of the converter and isolated from the primary side signal type state attribute symbol conditions / notes min nom max unit digital input any en enable threshold v enable-en 2.31 v en disable threshold v enable-dis needs vdde preapplied 0.99 v internally generated v cc v cc 3.23 3.30 3.37 v en internal pull up resistance to v cc r enable-int 0.990 1.000 1.010 k trim: tr ? the tr pin enables and disables trim functionality when v in is initially applied to the dcm converter. when vin ?rst crosses v in-uvlo+ , the voltage on tr determines whether or not trim is active. ? if tr is not ?oating at power up and has a voltage less than tr trim enable threshold, trim is active. ? if trim is active, the tr pin provides dynamic trim control with at least 250 hz of -3db control bandwidth over the output voltage of the dcm converter. ? the tr pin has an internal pull-up to v cc and is referenced to the Cout pin of the converter. ?v trim-range represents the trim pin functional limits only. module performance is guaranteed within rated output voltage trim range v out-trimming , see electrical speci?cation on page 5. signal type state attribute symbol conditions / notes min nom max unit digital input startup tr trim disable threshold v trim-dis trim disabled when tr above this threshold at power up 3.20 v tr trim enable threshold v trim-en trim enabled when tr below this threshold at power up 3.10 v analog input operational with trim enabled internally generated v cc v cc 3.23 3.30 3.37 v tr pin functional range v trim-range functional limits only 0.00 2.37 3.10 v v out referred tr pin resolution v out-res with v cc = 3.3 v 8.79 mv tr internal pull up resistance to v cc r trim-int 0.999 1.000 1.001 k dcm3414x50m06a8yzz dcm ? in a via package rev 1.3 vicorpower.com page 7 of 22 07/2017 800 927.9474 [2] signal cable 42550 is rated for up to 5 insertions and extractions. to avoid unnecessary stress on the connector, the cable should be tied to the chassis. vdde ? vdde powers the internal controller. ? vdde needs to be preapplied before v in in order to activate en functionalities. ? if not preapplied, vdde is derived from v out ; however, in this case, the enable function is not activated (the unit is always enabled and can be disabled only by removing v in .) ? if vdde is removed during operation, the unit will return in"always enabled" mode, ignoring the en pin until vdde is reapplied and v in is cycled. signal type state attribute symbol conditions / notes min nom max unit power input any power input for internal controller vdde 4 5 10 v vdde current consumption i vdde 35 50 ma signal speci?cations (cont.) specifications apply over all line, trim and load conditions, internal temperature t int = 25oc, unless otherwise noted. boldface specifications apply over the temperature range specified by the product grade. please note: for chassis mount models, vicor part number 42550 will be needed for applications requiring the use of signal pins (enable, trim and sense functions). +sense, Csense ? provide remote sense capability. ? if ?oating, the dcm automatically implements local sense operation. to achieve maximum regulation accuracy in local sense, the sense pins should be connected directly to their respective out pins. if sense pins are ?oating, the regulation accuracy degrades (see v out accuracy with sense pins ?oating on page 5). ? module performance is guaranteed for v out_to_load within rated limits speci?ed below. for v out_to_load higher than the speci?ed limits, regulation accuracy is not guaranteed. also, high v out_to_load might trigger ovp (for above nominal trim conditions), and might cause load voltage runaway (which might trigger uvp). attribute symbol conditions / notes min nom max unit remote sense rated voltage drop v out_to_load rated voltage drop between dcm package output and sense point at the load, in remote sense operation. module performance is guaranteed for v out_to_load below this threshold. 120 mv +se nse -se nse l o a d dcm tm in ? a?ackage c out-ext r line l line + - v load r line l line + - v out dcm3414x50m06a8yzz dcm ? in a via package rev 1.3 vicorpower.com page 8 of 22 07/2017 800 927.9474 v out-nom v out v in-uvlo+/- i out full load v out-uvp v in-ovlo+/- v in tr i load input output en 1 input power on - trim inactive 3 tr ignored 4 en low 5 en high 6 input ovlo 7 input uvlo 2 ramp to full load t init t on t ss t off t off t ss t ss t off t off 8 input returned to zero v tr-dis t min_off t ss t on v in-init timing diagrams module inputs are shown in blue; module outputs are shown in brown. timing diagrams assume vdde pre-applied. without vdde pre-applied, en is ignored, en and trim will go high after v out . all other behaviors (ovlo, uvlo, ovp, etc.) will remain the same. dcm3414x50m06a8yzz dcm ? in a via package rev 1.3 vicorpower.com page 9 of 22 07/2017 800 927.9474 v out-nom v out v in-uvlo+/- i out full load v out-uvp v in-ovlo+/- v in tr i load input output en v tr = nom v tr-en v out-ovp 9 input power on - trim active 11 load dump and reverse current 12 vout ovp (primary sensed) 14 current limit with resistive load 15 resistive load with decreasing r 10 vout based on v tr t init t on t ss t off t init t on t ss t init t on t ss 13 latched fault cleared t iout-lim 16 overload induced output uvp t fault r load v in-init timing diagrams (cont.) module inputs are shown in blue; module outputs are shown in brown. timing diagrams assume vdde pre-applied. without vdde pre-applied, en is ignored, en and trim will go high after v out . all other behaviors (ovlo, uvlo, ovp, etc.) will remain the same. dcm3414x50m06a8yzz dcm ? in a via package rev 1.3 vicorpower.com page 10 of 22 07/2017 800 927.9474 |